... ... @@ -99,22 +99,135 @@
99 99  * Sleep Mode: 5uA @ 3.3v
100 100  * LoRa Transmit Mode: 125mA @ 20dBm, 82mA @ 14dBm
101 101  
102 +== 1.4 Suitable Container & Liquid ==
102 102  
103 -== 1.4 Applications ==
104 104  
105 +* Solid Wall container such as: steel, iron, glass, ceramics, non-foaming plastics etc.
106 +* Container shape is regular, and surface is smooth.
107 +* Container Thickness:
108 +** Pure metal material.  2~~8mm, best is 3~~5mm
109 +** Pure non metal material: <10 mm
110 +* Pure liquid without irregular deposition.
105 105  
106 -* Horizontal distance measurement
107 -* Parking management system
108 -* Object proximity and presence detection
109 -* Intelligent trash can management system
110 -* Robot obstacle avoidance
111 -* Automatic control
112 -* Sewer
112 +(% style="display:none" %)
113 113  
114 +== 1.5 Install LDS12-LB ==
114 114  
116 +
117 +(% style="color:blue" %)**Step 1**(%%):  ** Choose the installation point.**
118 +
119 +LDS12-LB (% style="color:red" %)**MUST**(%%) be installed on the container bottom middle position.
120 +
121 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDDS20%20-%20LoRaWAN%20Liquid%20Level%20Sensor%20User%20Manual/WebHome/image-20220615091045-3.png?rev=1.1||alt="image-20220615091045-3.png"]]
122 +
123 +
124 +(((
125 +(% style="color:blue" %)**Step 2**(%%):  **Polish the installation point.**
126 +)))
127 +
128 +(((
129 +For Metal Surface with paint, it is important to polish the surface, first use crude sand paper to polish the paint level , then use exquisite sand paper to polish the metal level to make it shine & smooth.
130 +)))
131 +
132 +[[image:image-20230613143052-5.png]]
133 +
134 +
135 +No polish needed if the container is shine metal surface without paint or non-metal container.
136 +
137 +[[image:image-20230613143125-6.png]]
138 +
139 +
140 +(((
141 +(% style="color:blue" %)**Step3:   **(%%)**Test the installation point.**
142 +)))
143 +
144 +(((
145 +Power on LDS12-LB, check if the blue LED is on, If the blue LED is on, means the sensor works. Then put ultrasonic coupling paste on the sensor and put it tightly on the installation point.
146 +)))
147 +
148 +(((
149 +It is necessary to put the coupling paste between the sensor and the container, otherwise LDS12-LB won't detect the liquid level.
150 +)))
151 +
152 +(((
153 +After paste the LDS12-LB well, power on LDS12-LB. In the first 30 seconds of booting, device will check the sensors status and BLUE LED will show the status as below. After 30 seconds, BLUE LED will be off to save battery life.
154 +)))
155 +
156 +
157 +(((
158 +(% style="color:blue" %)**LED Status:**
159 +)))
160 +
161 +* (((
162 +**Onboard LED**: When power on device, the onboard LED will fast blink 4 times which means detect the sensor well.
163 +)))
164 +
165 +* (((
166 +(% style="color:blue" %)**BLUE LED**(% style="color:red" %)** always ON**(%%): Sensor is power on but doesn't detect liquid. There is problem in installation point.
167 +)))
168 +* (((
169 +(% style="color:blue" %)**BLUE LED**(% style="color:red" %)** slowly blinking**(%%): Sensor detects Liquid Level, The installation point is good.
170 +)))
171 +
172 +(((
173 +LDS12-LB will enter into low power mode at 30 seconds after system reset or power on, Blue LED will be off after that.
174 +)))
175 +
176 +
177 +(((
178 +(% style="color:red" %)**Note :**(%%)** (% style="color:blue" %)Ultrasonic coupling paste(%%)**(% style="color:blue" %) (%%) is subjected in most shipping way. So the default package doesn't include it and user needs to purchase locally.
179 +)))
180 +
181 +
182 +(((
183 +(% style="color:blue" %)**Step4:   **(%%)**Install use Epoxy ab glue.**
184 +)))
185 +
186 +(((
187 +Prepare Eproxy AB glue.
188 +)))
189 +
190 +(((
191 +Put Eproxy AB glue in the sensor and press it hard on the container installation point.
192 +)))
193 +
194 +(((
195 +Reset LDS12-LB and see if the BLUE LED is slowly blinking.
196 +)))
197 +
198 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDDS20%20-%20LoRaWAN%20Liquid%20Level%20Sensor%20User%20Manual/WebHome/image-20220615091045-8.png?width=341&height=203&rev=1.1||alt="image-20220615091045-8.png"]] [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDDS20%20-%20LoRaWAN%20Liquid%20Level%20Sensor%20User%20Manual/WebHome/image-20220615091045-9.png?width=284&height=200&rev=1.1||alt="image-20220615091045-9.png"]]
199 +
200 +
201 +(((
202 +(% style="color:red" %)**Note :**
203 +
204 +(% style="color:red" %)**1:**(%%)** (% style="color:blue" %)Eproxy AB glue(%%)** needs 3~~ 5 minutes to stable attached. we can use other glue material to keep it in the position.
205 +)))
206 +
207 +(((
208 +(% style="color:red" %)**2:**(%%)** (% style="color:blue" %)Eproxy AB glue(%%)** is subjected in most shipping way. So the default package doesn't include it and user needs to purchase locally.
209 +)))
210 +
211 +
212 +== 1.6 Applications ==
213 +
214 +
215 +* Smart liquid control solution
216 +
217 +* Smart liquefied gas solution
218 +
219 +== 1.7 Precautions ==
220 +
221 +
222 +* At room temperature, containers of different materials, such as steel, glass, iron, ceramics, non-foamed plastics and other dense materials, have different detection blind areas and detection limit heights.
223 +
224 +* For containers of the same material at room temperature, the detection blind zone and detection limit height are also different for the thickness of the container.
225 +
226 +* When the detected liquid level exceeds the effective detection value of the sensor, and the liquid level of the liquid to be measured shakes or tilts, the detected liquid height is unstable.
227 +
115 115  (% style="display:none" %)
116 116  
117 -== 1.5 Sleep mode and working mode ==
230 +== 1.8 Sleep mode and working mode ==
118 118  
119 119  
120 120  (% style="color:blue" %)**Deep Sleep Mode: **(%%)Sensor doesn't have any LoRaWAN activate. This mode is used for storage and shipping to save battery life.
... ... @@ -122,7 +122,7 @@
122 122  (% style="color:blue" %)**Working Mode:** (%%)In this mode, Sensor will work as LoRaWAN Sensor to Join LoRaWAN network and send out sensor data to server. Between each sampling/tx/rx periodically, sensor will be in IDLE mode), in IDLE mode, sensor has the same power consumption as Deep Sleep mode.
123 123  
124 124  
125 -== 1.6 Button & LEDs ==
238 +== 1.9 Button & LEDs ==
126 126  
127 127  
128 128  [[image:Main.User Manual for LoRaWAN End Nodes.D20-LBD22-LBD23-LB_LoRaWAN_Temperature_Sensor_User_Manual.WebHome@1675071855856-879.png]]
... ... @@ -141,7 +141,7 @@
141 141  )))
142 142  |(% style="width:167px" %)Fast press ACT 5 times.|(% style="width:117px" %)Deactivate Device|(% style="width:225px" %)(% style="color:red" %)**Red led**(%%) will solid on for 5 seconds. Means device is in Deep Sleep Mode.
143 143  
144 -== 1.7 BLE connection ==
257 +== 1.10 BLE connection ==
145 145  
146 146  
147 147  LDS12-LB support BLE remote configure.
... ... @@ -155,15 +155,14 @@
155 155  If there is no activity connection on BLE in 60 seconds, sensor will shut down BLE module to enter low power mode.
156 156  
157 157  
158 -== 1.8 Pin Definitions ==
271 +== 1.11 Pin Definitions ==
159 159  
160 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/WL03A-LB_LoRaWAN_None-Position_Rope_Type_Water_Leak_Controller_User_Manual/WebHome/image-20230613144156-1.png?rev=1.1||alt="image-20230613144156-1.png"]]
273 +[[image:image-20230523174230-1.png]]
161 161  
162 162  
276 +== 1.12 Mechanical ==
163 163  
164 -== 1.9 Mechanical ==
165 165  
166 -
167 167  [[image:Main.User Manual for LoRaWAN End Nodes.D20-LBD22-LBD23-LB_LoRaWAN_Temperature_Sensor_User_Manual.WebHome@1675143884058-338.png]]
168 168  
169 169  
... ... @@ -248,23 +248,21 @@
248 248  )))
249 249  
250 250  (((
251 -Uplink payload includes in total 11 bytes.
363 +Uplink payload includes in total 8 bytes.
252 252  )))
253 253  
254 -
255 -(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %)
256 -|=(% style="width: 62.5px;background-color:#4F81BD;color:white" %)(((
366 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:510px" %)
367 +|=(% style="width: 62.5px;background-color:#D9E2F3;color:#0070C0" %)(((
257 257  **Size(bytes)**
258 -)))|=(% style="width: 62.5px;background-color:#4F81BD;color:white" %)**2**|=(% style="width: 62.5px;background-color:#4F81BD;color:white" %)**2**|=(% style="background-color:#4F81BD;color:white" %)**2**|=(% style="background-color:#4F81BD;color:white" %)**2**|=(% style="background-color:#4F81BD;color:white" %)**1**|=(% style="background-color:#4F81BD;color:white" %)**1**|=(% style="background-color:#4F81BD;color:white" %)**1**
259 -|(% style="width:62.5px" %)**Value**|(% style="width:62.5px" %)[[BAT>>||anchor="H2.3.1A0BatteryInfo"]]|(% style="width:62.5px" %)(((
260 -[[Temperature DS18B20>>||anchor="H2.3.2A0DS18B20Temperaturesensor"]]
261 -)))|[[Distance>>||anchor="H2.3.3A0Distance"]]|[[Distance signal strength>>||anchor="H2.3.4A0Distancesignalstrength"]]|(((
262 -[[Interrupt flag>>||anchor="H2.3.5A0InterruptPin"]]
263 -)))|[[LiDAR temp>>||anchor="H2.3.6A0LiDARtemp"]]|(((
264 -[[Message Type>>||anchor="H2.3.7A0MessageType"]]
265 -)))
369 +)))|=(% style="width: 62.5px;background-color:#D9E2F3;color:#0070C0" %)**2**|=(% style="background-color:#D9E2F3;color:#0070C0" %)**2**|=(% style="background-color:#D9E2F3;color:#0070C0" %)1|=(% style="background-color:#D9E2F3;color:#0070C0" %)2|=(% style="background-color:#D9E2F3;color:#0070C0" %)**1**
370 +|(% style="width:62.5px" %)Value|(% style="width:62.5px" %)[[BAT>>||anchor="H2.3.1A0BatteryInfo"]]|(((
371 +[[Distance>>||anchor="H2.3.2A0Distance"]]
372 +(unit: mm)
373 +)))|[[Digital Interrupt (Optional)>>||anchor="H2.3.3A0InterruptPin"]]|(((
374 +[[Temperature (Optional )>>||anchor="H2.3.4A0DS18B20Temperaturesensor"]]
375 +)))|[[Sensor Flag>>||anchor="H2.3.5A0SensorFlag"]]
266 266  
267 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LLDS12-LoRaWAN%20LiDAR%20ToF%20Distance%20Sensor%20User%20Manual/WebHome/1654833689380-972.png?rev=1.1||alt="1654833689380-972.png"]]
377 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDDS20%20-%20LoRaWAN%20Liquid%20Level%20Sensor%20User%20Manual/WebHome/1654850511545-399.png?rev=1.1||alt="1654850511545-399.png"]]
268 268  
269 269  
270 270  === 2.3.1  Battery Info ===
... ... @@ -277,50 +277,28 @@
277 277  Ex2: 0x0B49 = 2889mV
278 278  
279 279  
280 -=== 2.3.2  DS18B20 Temperature sensor ===
390 +=== 2.3.2  Distance ===
281 281  
282 282  
283 -This is optional, user can connect external DS18B20 sensor to the +3.3v, 1-wire and GND pin . and this field will report temperature.
393 +(((
394 +Get the distance. Flat object range 20mm - 2000mm.
395 +)))
284 284  
397 +(((
398 +For example, if the data you get from the register is **0x06 0x05**, the distance between the sensor and the measured object is(% style="color:#4472c4" %)** **
285 285  
286 -**Example**:
400 +(% style="color:blue" %)**0605(H) = 1541 (D) = 1541 mm.**
401 +)))
287 287  
288 -If payload is: 0105H:  (0105 & FC00 == 0), temp = 0105H /10 = 26.1 degree
403 +* If the sensor value is 0x0000, it means system doesn't detect ultrasonic sensor.
289 289  
290 -If payload is: FF3FH (FF3F & FC00 == 1) , temp = (FF3FH - 65536)/10 = -19.3 degrees.
405 +* If the sensor value lower than 0x0014 (20mm), the sensor value will be invalid.
291 291  
407 +=== 2.3.3  Interrupt Pin ===
292 292  
293 -=== 2.3.3  Distance ===
294 294  
410 +This data field shows if this packet is generated by interrupt or not. [[Click here>>||anchor="H3.3.2SetInterruptMode"]] for the hardware and software set up.
295 295  
296 -Represents the distance value of the measurement output, the default unit is cm, and the value range parsed as a decimal number is 0-1200. In actual use, when the signal strength value Strength.
297 -
298 -
299 -**Example**:
300 -
301 -If the data you get from the register is 0x0B 0xEA, the distance between the sensor and the measured object is 0BEA(H) = 3050 (D)/10 = 305cm.
302 -
303 -
304 -=== 2.3.4  Distance signal strength ===
305 -
306 -
307 -Refers to the signal strength, the default output value will be between 0-65535. When the distance measurement gear is fixed, the farther the distance measurement is, the lower the signal strength; the lower the target reflectivity, the lower the signal strength. When Strength is greater than 100 and not equal to 65535, the measured value of Dist is considered credible.
308 -
309 -
310 -**Example**:
311 -
312 -If payload is: 01D7(H)=471(D), distance signal strength=471, 471>100,471≠65535, the measured value of Dist is considered credible.
313 -
314 -Customers can judge whether they need to adjust the environment based on the signal strength.
315 -
316 -
317 -=== 2.3.5  Interrupt Pin ===
318 -
319 -
320 -This data field shows if this packet is generated by interrupt or not. [[Click here>>||anchor="H4.2A0SetInterruptMode"]] for the hardware and software set up.
321 -
322 -Note: The Internet Pin is a separate pin in the screw terminal. See [[pin mapping>>||anchor="H1.6A0Pinmappingandpoweron"]].
323 -
324 324  **Example:**
325 325  
326 326  0x00: Normal uplink packet.
... ... @@ -328,50 +328,44 @@
328 328  0x01: Interrupt Uplink Packet.
329 329  
330 330  
331 -=== 2.3.6  LiDAR temp ===
419 +=== 2.3.4  DS18B20 Temperature sensor ===
332 332  
333 333  
334 -Characterize the internal temperature value of the sensor.
422 +This is optional, user can connect external DS18B20 sensor to the +3.3v, 1-wire and GND pin . and this field will report temperature.
335 335  
336 -**Example: **
337 -If payload is: 1C(H) <<24>>24=28(D),LiDAR temp=28℃.
338 -If payload is: F2(H) <<24>>24=-14(D),LiDAR temp=-14℃.
424 +**Example**:
339 339  
426 +If payload is: 0105H:  (0105 & FC00 == 0), temp = 0105H /10 = 26.1 degree
340 340  
341 -=== 2.3. Message Type ===
428 +If payload is: FF3FH :  (FF3F & FC00 == 1) , temp = (FF3FH - 65536)/10 = -19.3 degrees.
342 342  
343 343  
431 +=== 2.3.5  Sensor Flag ===
432 +
433 +
344 344  (((
345 -For a normal uplink payload, the message type is always 0x01.
435 +0x01: Detect Ultrasonic Sensor
346 346  )))
347 347  
348 348  (((
349 -Valid Message Type:
439 +0x00: No Ultrasonic Sensor
350 350  )))
351 351  
352 -(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:499px" %)
353 -|=(% style="width: 161px;background-color:#4F81BD;color:white" %)**Message Type Code**|=(% style="width: 164px;background-color:#4F81BD;color:white" %)**Description**|=(% style="width: 174px;background-color:#4F81BD;color:white" %)**Payload**
354 -|(% style="width:160px" %)0x01|(% style="width:163px" %)Normal Uplink|(% style="width:173px" %)[[Normal Uplink Payload>>||anchor="H2.3A0200BUplinkPayload"]]
355 -|(% style="width:160px" %)0x02|(% style="width:163px" %)Reply configures info|(% style="width:173px" %)[[Configure Info Payload>>||anchor="H4.3A0GetFirmwareVersionInfo"]]
356 356  
357 -=== 2.3.8  Decode payload in The Things Network ===
443 +=== 2.3.6  Decode payload in The Things Network ===
358 358  
359 359  
360 360  While using TTN network, you can add the payload format to decode the payload.
361 361  
448 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDDS75%20-%20LoRaWAN%20Distance%20Detection%20Sensor%20User%20Manual/WebHome/1654850829385-439.png?rev=1.1||alt="1654850829385-439.png"]]
362 362  
363 -[[image:1654592762713-715.png]]
450 +The payload decoder function for TTN V3 is here:
364 364  
365 -
366 366  (((
367 -The payload decoder function for TTN is here:
453 +LDS12-LB TTN V3 Payload Decoder:  [[ttps:~~/~~/github.com/dragino/dragino-end-node-decoder>>https://github.com/dragino/dragino-end-node-decoder]]
368 368  )))
369 369  
370 -(((
371 -LDS12-LB TTN Payload Decoder:  [[https:~~/~~/github.com/dragino/dragino-end-node-decoder>>https://github.com/dragino/dragino-end-node-decoder]]
372 -)))
373 373  
374 -
375 375  == 2.4  Uplink Interval ==
376 376  
377 377  
... ... @@ -498,94 +498,6 @@
498 498  [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20Frequency%20Band/>>http://wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20Frequency%20Band/]]
499 499  
500 500  
501 -== 2.8 LiDAR ToF Measurement ==
502 -
503 -=== 2.8.1 Principle of Distance Measurement ===
504 -
505 -
506 -The LiDAR probe is based on TOF, namely, Time of Flight principle. To be specific, the product emits modulation wave of near infrared ray on a periodic basis, which will be reflected after contacting object. The product obtains the time of flight by measuring round-trip phase difference and then calculates relative range between the product and the detection object, as shown below.
507 -
508 -
509 -[[image:1654831757579-263.png]]
510 -
511 -
512 -=== 2.8.2 Distance Measurement Characteristics ===
513 -
514 -
515 -With optimization of light path and algorithm, The LiDAR probe has minimized influence from external environment on distance measurement performance. Despite that, the range of distance measurement may still be affected by the environment illumination intensity and the reflectivity of detection object. As shown in below:
516 -
517 -[[image:1654831774373-275.png]]
518 -
519 -
520 -(((
521 -(% style="color:blue" %)**① **(%%)Represents the detection blind zone of The LiDAR probe, 0-10cm, within which the output data is unreliable.
522 -)))
523 -
524 -(((
525 -(% style="color:blue" %)**② **(%%)Represents the operating range of The LiDAR probe detecting black target with 10% reflectivity, 0.1-5m.
526 -)))
527 -
528 -(((
529 -(% style="color:blue" %)**③ **(%%)Represents the operating range of The LiDAR probe detecting white target with 90% reflectivity, 0.1-12m.
530 -)))
531 -
532 -
533 -(((
534 -Vertical Coordinates: Represents the radius of light spot for The LiDAR probe at different distances. The diameter of light spot depends on the FOV of The LiDAR probe (the term of FOV generally refers to the smaller value between the receiving angle and the transmitting angle), which is calculated as follows:
535 -)))
536 -
537 -
538 -[[image:1654831797521-720.png]]
539 -
540 -
541 -(((
542 -In the formula above, d is the diameter of light spot; D is detecting range; β is the value of the receiving angle of The LiDAR probe, 3.6°. Correspondence between the diameter of light spot and detecting range is given in Table below.
543 -)))
544 -
545 -[[image:1654831810009-716.png]]
546 -
547 -
548 -(((
549 -If the light spot reaches two objects with different distances, as shown in Figure 3, the output distance value will be a value between the actual distance values of the two objects. For a high accuracy requirement in practice, the above situation should be noticed to avoid the measurement error.
550 -)))
551 -
552 -
553 -=== 2.8.3 Notice of usage: ===
554 -
555 -
556 -Possible invalid /wrong reading for LiDAR ToF tech:
557 -
558 -* Measure high reflectivity object such as: Mirror, Smooth ceramic tile, static milk surface, will have possible wrong readings.
559 -* While there is transparent object such as glass, water drop between the measured object and the LiDAR sensor, the reading might be wrong.
560 -* The LiDAR probe is cover by dirty things; the reading might be wrong. In this case, need to clean the probe.
561 -* The sensor window is made by Acrylic. Don't touch it with alcohol material. This will destroy the sensor window.
562 -
563 -=== 2.8.4  Reflectivity of different objects ===
564 -
565 -
566 -(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:379px" %)
567 -|=(% style="width: 54px;background-color:#D9E2F3;color:#0070C0" %)Item|=(% style="width: 231px;background-color:#D9E2F3;color:#0070C0" %)Material|=(% style="width: 94px;background-color:#D9E2F3;color:#0070C0" %)Relectivity
568 -|(% style="width:53px" %)1|(% style="width:229px" %)Black foam rubber|(% style="width:93px" %)2.4%
569 -|(% style="width:53px" %)2|(% style="width:229px" %)Black fabric|(% style="width:93px" %)3%
570 -|(% style="width:53px" %)3|(% style="width:229px" %)Black rubber|(% style="width:93px" %)4%
571 -|(% style="width:53px" %)4|(% style="width:229px" %)Coal (different types of coal)|(% style="width:93px" %)4~~8%
572 -|(% style="width:53px" %)5|(% style="width:229px" %)Black car paint|(% style="width:93px" %)5%
573 -|(% style="width:53px" %)6|(% style="width:229px" %)Black Jam|(% style="width:93px" %)10%
574 -|(% style="width:53px" %)7|(% style="width:229px" %)Opaque black plastic|(% style="width:93px" %)14%
575 -|(% style="width:53px" %)8|(% style="width:229px" %)Clean rough board|(% style="width:93px" %)20%
576 -|(% style="width:53px" %)9|(% style="width:229px" %)Translucent plastic bottle|(% style="width:93px" %)62%
577 -|(% style="width:53px" %)10|(% style="width:229px" %)Carton cardboard|(% style="width:93px" %)68%
578 -|(% style="width:53px" %)11|(% style="width:229px" %)Clean pine|(% style="width:93px" %)70%
579 -|(% style="width:53px" %)12|(% style="width:229px" %)Opaque white plastic|(% style="width:93px" %)87%
580 -|(% style="width:53px" %)13|(% style="width:229px" %)White Jam|(% style="width:93px" %)90%
581 -|(% style="width:53px" %)14|(% style="width:229px" %)Kodak Standard Whiteboard|(% style="width:93px" %)100%
582 -|(% style="width:53px" %)15|(% style="width:229px" %)(((
583 -Unpolished white metal surface
584 -)))|(% style="width:93px" %)130%
585 -|(% style="width:53px" %)16|(% style="width:229px" %)Glossy light metal surface|(% style="width:93px" %)150%
586 -|(% style="width:53px" %)17|(% style="width:229px" %)stainless steel|(% style="width:93px" %)200%
587 -|(% style="width:53px" %)18|(% style="width:229px" %)Reflector plate, reflective tape|(% style="width:93px" %)>300%
588 -
589 589  = 3. Configure LDS12-LB =
590 590  
591 591  == 3.1 Configure Methods ==
... ... @@ -659,6 +659,9 @@
659 659  )))
660 660  * (((
661 661  Example 2: Downlink Payload: 0100003C  ~/~/ Set Transmit Interval (TDC) = 60 seconds 
656 +
657 +
658 +
662 662  )))
663 663  
664 664  === 3.3.2 Set Interrupt Mode ===
... ... @@ -695,87 +695,6 @@
695 695  
696 696  * Example 2: Downlink Payload: 06000003  ~/~/  Set the interrupt mode to rising edge trigger
697 697  
698 -
699 -
700 -=== 3.3.3 Get Firmware Version Info ===
701 -
702 -
703 -Feature: use downlink to get firmware version.
704 -
705 -(% style="color:#037691" %)**Downlink Command: 0x26**
706 -
707 -(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:492px" %)
708 -|(% style="background-color:#d9e2f3; color:#0070c0; width:191px" %)**Downlink Control Type**|(% style="background-color:#d9e2f3; color:#0070c0; width:57px" %)**FPort**|(% style="background-color:#d9e2f3; color:#0070c0; width:91px" %)**Type Code**|(% style="background-color:#d9e2f3; color:#0070c0; width:153px" %)**Downlink payload size(bytes)**
709 -|(% style="width:191px" %)Get Firmware Version Info|(% style="width:57px" %)Any|(% style="width:91px" %)26|(% style="width:151px" %)2
710 -
711 -* Reply to the confirmation package: 26 01
712 -* Reply to non-confirmed packet: 26 00
713 -
714 -Device will send an uplink after got this downlink command. With below payload:
715 -
716 -Configures info payload:
717 -
718 -(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:510px" %)
719 -|=(% style="background-color:#D9E2F3;color:#0070C0" %)(((
720 -**Size(bytes)**
721 -)))|=(% style="background-color:#D9E2F3;color:#0070C0" %)**1**|=(% style="background-color:#D9E2F3;color:#0070C0" %)**1**|=(% style="background-color:#D9E2F3;color:#0070C0" %)**1**|=(% style="background-color:#D9E2F3;color:#0070C0" %)**1**|=(% style="background-color:#D9E2F3;color:#0070C0" %)**1**|=(% style="background-color:#D9E2F3;color:#0070C0" %)**5**|=(% style="background-color:#D9E2F3;color:#0070C0" %)**1**
722 -|**Value**|Software Type|(((
723 -Frequency
724 -Band
725 -)))|Sub-band|(((
726 -Firmware
727 -Version
728 -)))|Sensor Type|Reserve|(((
729 -[[Message Type>>||anchor="H2.3.7A0MessageType"]]
730 -Always 0x02
731 -)))
732 -
733 -(% style="color:#037691" %)**Software Type**(%%): Always 0x03 for LLDS12
734 -
735 -(% style="color:#037691" %)**Frequency Band**:
736 -
737 -*0x01: EU868
738 -
739 -*0x02: US915
740 -
741 -*0x03: IN865
742 -
743 -*0x04: AU915
744 -
745 -*0x05: KZ865
746 -
747 -*0x06: RU864
748 -
749 -*0x07: AS923
750 -
751 -*0x08: AS923-1
752 -
753 -*0x09: AS923-2
754 -
755 -*0xa0: AS923-3
756 -
757 -
758 -(% style="color:#037691" %)**Sub-Band**(%%): value 0x00 ~~ 0x08
759 -
760 -(% style="color:#037691" %)**Firmware Version**(%%): 0x0100, Means: v1.0.0 version
761 -
762 -(% style="color:#037691" %)**Sensor Type**:
763 -
764 -0x01: LSE01
765 -
766 -0x02: LDDS75
767 -
768 -0x03: LDDS20
769 -
770 -0x04: LLMS01
771 -
772 -0x05: LSPH01
773 -
774 -0x06: LSNPK01
775 -
776 -0x07: LLDS12
777 -
778 -
779 779  = 4. Battery & Power Consumption =
780 780  
781 781