Changes for page DS20L -- LoRaWAN Smart Distance Detector User Manual 01
Last modified by Mengting Qiu on 2023/12/14 11:15
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 4 removed)
Details
- Page properties
-
- Content
-
... ... @@ -22,7 +22,7 @@ 22 22 == 1.1 What is LoRaWAN Ultrasonic liquid level Sensor == 23 23 24 24 25 -The Dragino DDS20-LB is a (% style="color:blue" %)**LoRaWAN Ultrasonic liquid level sensor**(%%) for Internet of Things solution. It uses (% style="color:blue" %)**none-contact method **(%%)to measure the (% style="color:blue" %)**height of liquid**(%%) in a container without opening the container, and send the value via LoRaWAN network to IoT Server. 25 +The Dragino DDS20-LB is a (% style="color:blue" %)**LoRaWAN Ultrasonic liquid level sensor**(%%) for Internet of Things solution. It uses (% style="color:blue" %)**none-contact method **(%%)to measure the (% style="color:blue" %)****height of liquid**(%%) in a container without opening the container, and send the value via LoRaWAN network to IoT Server. 26 26 27 27 The DDS20-LB sensor is installed directly below the container to detect the height of the liquid level. User doesn't need to open a hole on the container to be tested. The none-contact measurement makes the measurement safety, easier and possible for some strict situation. 28 28 ... ... @@ -36,7 +36,7 @@ 36 36 37 37 Each DDS20-LB is pre-load with a set of unique keys for LoRaWAN registrations, register these keys to local LoRaWAN server and it will auto connect after power on. 38 38 39 -[[image:image-202306131 40115-3.png||height="453" width="800"]]39 +[[image:image-20230613102459-3.png||height="476" width="855"]] 40 40 41 41 42 42 == 1.2 Features == ... ... @@ -45,10 +45,10 @@ 45 45 * LoRaWAN 1.0.3 Class A 46 46 * Bands: CN470/EU433/KR920/US915/EU868/AS923/AU915/IN865 47 47 * Ultra-low power consumption 48 -* Liquid LevelMeasurement by Ultrasonic technology49 -* Measurethroughcontainer,Noneedto contact Liquid50 -* Valid levelrange20mm-2000mm51 -* Accuracy: ±(5mm+S*0.5%) (S:MeasureValue)48 +* Distance Detection by Ultrasonic technology 49 +* Flat object range 30mm - 4500mm 50 +* Accuracy: ±(1cm+S*0.3%) (S: Distance) 51 +* Measure Angle: 60° 52 52 * Cable Length : 25cm 53 53 * Support Bluetooth v5.1 and LoRaWAN remote configure 54 54 * Support wireless OTA update firmware ... ... @@ -57,6 +57,7 @@ 57 57 * IP66 Waterproof Enclosure 58 58 * 8500mAh Battery for long term use 59 59 60 + 60 60 == 1.3 Specification == 61 61 62 62 ... ... @@ -85,159 +85,71 @@ 85 85 * Sleep Mode: 5uA @ 3.3v 86 86 * LoRa Transmit Mode: 125mA @ 20dBm, 82mA @ 14dBm 87 87 88 -== 1.4 Suitable Container & Liquid == 89 89 90 +== 1.4 Rated environmental conditions == 90 90 91 -* Solid Wall container such as: steel, iron, glass, ceramics, non-foaming plastics etc. 92 -* Container shape is regular, and surface is smooth. 93 -* Container Thickness: 94 -** Pure metal material. 2~~8mm, best is 3~~5mm 95 -** Pure non metal material: <10 mm 96 -* Pure liquid without irregular deposition.(% style="display:none" %) 97 97 93 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:500px" %) 94 +|(% style="background-color:#d9e2f3; color:#0070c0; width:163px" %)**Item**|(% style="background-color:#d9e2f3; color:#0070c0; width:90px" %)((( 95 +**Minimum value** 96 +)))|(% style="background-color:#d9e2f3; color:#0070c0; width:70px" %)((( 97 +**Typical value** 98 +)))|(% style="background-color:#d9e2f3; color:#0070c0; width:87px" %)((( 99 +**Maximum value** 100 +)))|(% style="background-color:#d9e2f3; color:#0070c0; width:40px" %)**Unit**|(% style="background-color:#d9e2f3; color:#0070c0; width:50px" %)**Remarks** 101 +|(% style="width:174px" %)Storage temperature|(% style="width:86px" %)-25|(% style="width:66px" %)25|(% style="width:90px" %)80|(% style="width:48px" %)℃|(% style="width:203px" %) 102 +|(% style="width:174px" %)Storage humidity|(% style="width:86px" %) |(% style="width:66px" %)65%|(% style="width:90px" %)90%|(% style="width:48px" %)RH|(% style="width:203px" %)(1) 103 +|(% style="width:174px" %)Operating temperature|(% style="width:86px" %)-15|(% style="width:66px" %)25|(% style="width:90px" %)60|(% style="width:48px" %)℃|(% style="width:203px" %) 104 +|(% style="width:174px" %)Working humidity|(% style="width:86px" %)((( 105 + 98 98 99 -== 1.5 Install DDS20-LB == 107 + 108 +)))|(% style="width:66px" %)65%|(% style="width:90px" %)80%|(% style="width:48px" %)RH|(% style="width:203px" %)(1) 100 100 101 - 102 -(% style="color:blue" %)**Step 1**(%%): Choose the installation point. 103 - 104 -DDS20-LB (% style="color:red" %)**MUST**(%%) be installed on the container bottom middle position. 105 - 106 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDDS20%20-%20LoRaWAN%20Liquid%20Level%20Sensor%20User%20Manual/WebHome/image-20220615091045-3.png?rev=1.1||alt="image-20220615091045-3.png"]] 107 - 108 - 109 109 ((( 110 -(% style="color:blue" %)**Step 2**(%%): Polish the installation point. 111 -))) 111 +(% style="color:red" %)**Remarks: (1) a. When the ambient temperature is 0-39 ℃, the maximum humidity is 90% (non-condensing); ** 112 112 113 -((( 114 -For Metal Surface with paint, it is important to polish the surface, first use crude sand paper to polish the paint level , then use exquisite sand paper to polish the metal level to make it shine & smooth. 115 -))) 113 +(% style="color:red" %)** b. When the ambient temperature is 40-50 ℃, the highest humidity is the highest humidity in the natural world at the current temperature (no condensation)** 116 116 117 -[[image:image-20230613143052-5.png]] 118 - 119 - 120 -No polish needed if the container is shine metal surface without paint or non-metal container. 121 - 122 -[[image:image-20230613143125-6.png]] 123 - 124 - 125 - 126 -((( 127 -(% style="color:blue" %)**Step3: **(%%)Test the installation point. 115 + 128 128 ))) 129 129 130 -((( 131 -Power on DDS20-LB, check if the blue LED is on, If the blue LED is on, means the sensor works. Then put ultrasonic coupling paste on the sensor and put it tightly on the installation point. 132 -))) 118 +== 1.5 Effective measurement range Reference beam pattern == 133 133 134 134 135 -((( 136 -It is necessary to put the coupling paste between the sensor and the container, otherwise DDS20-LB won't detect the liquid level. 137 -))) 121 +(% style="color:blue" %)**1. The tested object is a white cylindrical tube made of PVC, with a height of 100cm and a diameter of 7.5cm.** 138 138 139 -[[image: 1655256160324-178.png||height="151"width="419"]][[image:image-20220615092327-13.png||height="146" width="260"]]123 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDDS75%20-%20LoRaWAN%20Distance%20Detection%20Sensor%20User%20Manual/WebHome/1654852253176-749.png?rev=1.1||alt="1654852253176-749.png"]] 140 140 141 141 142 -((( 143 -After paste the DDS20-LB well, power on DDS20-LB. In the first 30 seconds of booting, device will check the sensors status and BLUE LED will show the status as below. After 30 seconds, BLUE LED will be off to save battery life. 144 -))) 126 +(% style="color:blue" %)**2. The object to be tested is a "corrugated cardboard box" perpendicular to the central axis of 0 °, and the length * width is 60cm * 50cm.** 145 145 128 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDDS75%20-%20LoRaWAN%20Distance%20Detection%20Sensor%20User%20Manual/WebHome/1654852175653-550.png?rev=1.1||alt="1654852175653-550.png"]] 146 146 147 -((( 148 -(% style="color:red" %)**LED Status:** 149 -))) 150 150 151 -* ((( 152 -Onboard LED: When power on device, the onboard LED will fast blink 4 times which means detect the sensor well. 153 -))) 154 - 155 -* ((( 156 -(% style="color:blue" %)**BLUE LED**(% style="color:red" %)** always ON**(%%): Sensor is power on but doesn't detect liquid. There is problem in installation point. 157 -))) 158 -* ((( 159 -(% style="color:blue" %)**BLUE LED**(% style="color:red" %)** slowly blinking**(%%): Sensor detects Liquid Level, The installation point is good. 160 -))) 161 - 162 -((( 163 -LDDS20 will enter into low power mode at 30 seconds after system reset or power on, Blue LED will be off after that. 164 -))) 165 - 166 - 167 -((( 168 -(% style="color:red" %)**Note 2:** 169 -))) 170 - 171 -((( 172 -(% style="color:red" %)**Ultrasonic coupling paste** (%%) is subjected in most shipping way. So the default package doesn't include it and user needs to purchase locally. 173 -))) 174 - 175 - 176 -((( 177 -(% style="color:blue" %)**Step4: **(%%)Install use Epoxy ab glue. 178 -))) 179 - 180 -((( 181 -Prepare Eproxy AB glue. 182 -))) 183 - 184 -((( 185 -Put Eproxy AB glue in the sensor and press it hard on the container installation point. 186 -))) 187 - 188 -((( 189 -Reset DDS20-LB and see if the BLUE LED is slowly blinking. 190 -))) 191 - 192 -[[image:image-20220615091045-8.png||height="203" width="341"]] [[image:image-20220615091045-9.png||height="200" width="284"]] 193 - 194 - 195 -((( 196 -(% style="color:red" %)**Note 1:** 197 -))) 198 - 199 -((( 200 -Eproxy AB glue needs 3~~ 5 minutes to stable attached. we can use other glue material to keep it in the position. 201 -))) 202 - 203 - 204 -((( 205 -(% style="color:red" %)**Note 2:** 206 -))) 207 - 208 -((( 209 -(% style="color:red" %)**Eproxy AB glue**(%%) is subjected in most shipping way. So the default package doesn't include it and user needs to purchase locally. 210 -))) 211 - 212 - 213 213 == 1.6 Applications == 214 214 215 215 216 -* Smart liquid control solution. 134 +* Horizontal distance measurement 135 +* Liquid level measurement 136 +* Parking management system 137 +* Object proximity and presence detection 138 +* Intelligent trash can management system 139 +* Robot obstacle avoidance 140 +* Automatic control 141 +* Sewer 142 +* Bottom water level monitoring 217 217 218 -* Smart liquefied gas solution. 219 219 145 +== 1.7 Sleep mode and working mode == 220 220 221 221 222 -== 1.7 Precautions == 223 - 224 - 225 -* At room temperature, containers of different materials, such as steel, glass, iron, ceramics, non-foamed plastics and other dense materials, have different detection blind areas and detection limit heights. 226 - 227 -* For containers of the same material at room temperature, the detection blind zone and detection limit height are also different for the thickness of the container. 228 - 229 -* When the detected liquid level exceeds the effective detection value of the sensor, and the liquid level of the liquid to be measured shakes or tilts, the detected liquid height is unstable.(% style="display:none" %) 230 - 231 - 232 -== 1.8 Sleep mode and working mode == 233 - 234 - 235 235 (% style="color:blue" %)**Deep Sleep Mode: **(%%)Sensor doesn't have any LoRaWAN activate. This mode is used for storage and shipping to save battery life. 236 236 237 237 (% style="color:blue" %)**Working Mode:** (%%)In this mode, Sensor will work as LoRaWAN Sensor to Join LoRaWAN network and send out sensor data to server. Between each sampling/tx/rx periodically, sensor will be in IDLE mode), in IDLE mode, sensor has the same power consumption as Deep Sleep mode. 238 238 239 239 240 -== 1. 9Button & LEDs ==153 +== 1.8 Button & LEDs == 241 241 242 242 243 243 [[image:Main.User Manual for LoRaWAN End Nodes.D20-LBD22-LBD23-LB_LoRaWAN_Temperature_Sensor_User_Manual.WebHome@1675071855856-879.png]] ... ... @@ -256,11 +256,13 @@ 256 256 ))) 257 257 |(% style="width:167px" %)Fast press ACT 5 times.|(% style="width:117px" %)Deactivate Device|(% style="width:225px" %)(% style="color:red" %)**Red led**(%%) will solid on for 5 seconds. Means device is in Deep Sleep Mode. 258 258 259 -== 1.10 BLE connection == 260 260 173 +== 1.9 BLE connection == 261 261 262 -DDS20-LB support BLE remote configure. 263 263 176 +DDS45-LB support BLE remote configure. 177 + 178 + 264 264 BLE can be used to configure the parameter of sensor or see the console output from sensor. BLE will be only activate on below case: 265 265 266 266 * Press button to send an uplink ... ... @@ -270,12 +270,12 @@ 270 270 If there is no activity connection on BLE in 60 seconds, sensor will shut down BLE module to enter low power mode. 271 271 272 272 273 -== 1.1 1Pin Definitions ==188 +== 1.10 Pin Definitions == 274 274 275 275 [[image:image-20230523174230-1.png]] 276 276 277 277 278 -== 1.1 2Mechanical ==193 +== 1.11 Mechanical == 279 279 280 280 281 281 [[image:Main.User Manual for LoRaWAN End Nodes.D20-LBD22-LBD23-LB_LoRaWAN_Temperature_Sensor_User_Manual.WebHome@1675143884058-338.png]] ... ... @@ -289,14 +289,11 @@ 289 289 290 290 (% style="color:blue" %)**Probe Mechanical:** 291 291 292 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDDS 20%20-%20LoRaWAN%20Liquid%20Level%20Sensor%20User%20Manual/WebHome/image-20220615090910-1.png?rev=1.1||alt="image-20220615090910-1.png"]]207 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDDS45%20-%20LoRaWAN%20Distance%20Detection%20Sensor%20User%20Manual/WebHome/1654915562090-396.png?rev=1.1||alt="1654915562090-396.png"]] 293 293 294 294 295 - [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDDS20%20-%20LoRaWAN%20Liquid%20Level%20Sensor%20User%20Manual/WebHome/image-20220615090910-2.png?rev=1.1||alt="image-20220615090910-2.png"]]210 += 2. Configure DDS45-LB to connect to LoRaWAN network = 296 296 297 - 298 -= 2. Configure DDS20-LB to connect to LoRaWAN network = 299 - 300 300 == 2.1 How it works == 301 301 302 302 ... ... @@ -311,7 +311,7 @@ 311 311 312 312 The LPS8v2 is already set to connected to [[TTN network >>url:https://console.cloud.thethings.network/]], so what we need to now is configure the TTN server. 313 313 314 -[[image:image-202306131 40140-4.png||height="453" width="800"]](% style="display:none" %)226 +[[image:image-20230613102426-2.png||height="476" width="855"]](% style="display:none" %) 315 315 316 316 317 317 (% style="color:blue" %)**Step 1:**(%%) Create a device in TTN with the OTAA keys from DDS45-LB. ... ... @@ -406,6 +406,7 @@ 406 406 * If the sensor value is 0x0000, it means system doesn't detect ultrasonic sensor. 407 407 * If the sensor value lower than 0x001E (30mm), the sensor value will be 0x00. 408 408 321 + 409 409 === 2.3.3 Interrupt Pin === 410 410 411 411 ... ... @@ -596,6 +596,7 @@ 596 596 597 597 * LoRaWAN Downlink. Instruction for different platforms: See [[IoT LoRaWAN Server>>http://wiki.dragino.com/xwiki/bin/view/Main/]] section. 598 598 512 + 599 599 == 3.2 General Commands == 600 600 601 601 ... ... @@ -658,6 +658,7 @@ 658 658 Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds 659 659 ))) 660 660 575 + 661 661 === 3.3.2 Set Interrupt Mode === 662 662 663 663 ... ... @@ -692,6 +692,7 @@ 692 692 693 693 * Example 2: Downlink Payload: 06000003 ~/~/ Set the interrupt mode to rising edge trigger 694 694 610 + 695 695 = 4. Battery & Power Consumption = 696 696 697 697 ... ... @@ -720,6 +720,7 @@ 720 720 721 721 * Update through UART TTL interface: **[[Instruction>>url:http://wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H1.LoRaSTv4baseHardware]]**. 722 722 639 + 723 723 = 6. FAQ = 724 724 725 725 == 6.1 What is the frequency plan for DDS45-LB? == ... ... @@ -802,6 +802,7 @@ 802 802 803 803 * (% style="color:red" %)**CN470**(%%): LoRaWAN CN470 band 804 804 722 + 805 805 = 9. Packing Info = 806 806 807 807 ... ... @@ -819,6 +819,7 @@ 819 819 820 820 * Weight / pcs : g 821 821 740 + 822 822 = 10. Support = 823 823 824 824
- image-20230613140115-3.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -92.1 KB - Content
- image-20230613140140-4.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -92.1 KB - Content
- image-20230613143052-5.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -21.8 KB - Content
- image-20230613143125-6.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -24.7 KB - Content