Changes for page DS20L -- LoRaWAN Smart Distance Detector User Manual 01
Last modified by Mengting Qiu on 2023/12/14 11:15
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 3 removed)
Details
- Page properties
-
- Title
-
... ... @@ -1,1 +1,1 @@ 1 -DDS 45-LB -- LoRaWAN Distance Detection Sensor User Manual1 +DDS75-LB -- LoRaWAN Distance Detection Sensor User Manual - Content
-
... ... @@ -1,8 +1,9 @@ 1 1 (% style="text-align:center" %) 2 -[[image:image-2023061 3100900-1.png||height="650" width="650"]]2 +[[image:image-20230612170349-1.png||height="656" width="656"]] 3 3 4 4 5 5 6 + 6 6 **Table of Contents:** 7 7 8 8 {{toc/}} ... ... @@ -17,19 +17,19 @@ 17 17 == 1.1 What is LoRaWAN Distance Detection Sensor == 18 18 19 19 20 -The Dragino DDS 45-LB is a (% style="color:blue" %)** LoRaWAN Distance Detection Sensor**(%%) for Internet of Things solution. It is used to measure the distance between the sensor and a flat object. The distance detection sensor is a module that uses (% style="color:blue" %)** ultrasonic sensing technology**(%%) for (% style="color:blue" %)**distance measurement**(%%), and (% style="color:blue" %)** temperature compensation**(%%) is performed internally to improve the reliability of data. The DDS45-LB can be applied to scenarios such as horizontal distance measurement, liquid level measurement, parking management system, object proximity and presence detection, intelligent trash can management system, robot obstacle avoidance, automatic control, sewer, bottom water level monitoring, etc.21 +The Dragino DDS75-LB is a (% style="color:blue" %)** LoRaWAN Distance Detection Sensor**(%%) for Internet of Things solution. It is used to measure the distance between the sensor and a flat object. The distance detection sensor is a module that uses (% style="color:blue" %)** ultrasonic sensing technology**(%%) for (% style="color:blue" %)**distance measurement**(%%), and (% style="color:blue" %)** temperature compensation**(%%) is performed internally to improve the reliability of data. The DDS75-LB can be applied to scenarios such as horizontal distance measurement, liquid level measurement, parking management system, object proximity and presence detection, intelligent trash can management system, robot obstacle avoidance, automatic control, sewer, bottom water level monitoring, etc. 21 21 22 22 It detects the distance(% style="color:blue" %)** between the measured object and the sensor**(%%), and uploads the value via wireless to LoRaWAN IoT Server. 23 23 24 -The LoRa wireless technology used in DDS45-LB allows device to send data and reach extremely long ranges at low data-rates. It provides ultra-long range spread spectrum communication and high interference immunity whilst minimizing current consumption.25 +The LoRa wireless technology used in SW3L-LB allows device to send data and reach extremely long ranges at low data-rates. It provides ultra-long range spread spectrum communication and high interference immunity whilst minimizing current consumption. 25 25 26 - DDS45-LB (% style="color:blue" %)**supports BLE configure**(%%) and (% style="color:blue" %)**wireless OTA update**(%%) which make user easy to use.27 +SW3L-LB (% style="color:blue" %)**supports BLE configure**(%%) and (% style="color:blue" %)**wireless OTA update**(%%) which make user easy to use. 27 27 28 - DDS45-LB is powered by (% style="color:blue" %)**8500mAh Li-SOCI2 battery**(%%), it is designed for long term use up to 5 years.29 +SW3L-LB is powered by (% style="color:blue" %)**8500mAh Li-SOCI2 battery**(%%), it is designed for long term use up to 5 years. 29 29 30 -Each DDS45-LB is pre-load with a set of unique keys for LoRaWAN registrations, register these keys to local LoRaWAN server and it will auto connect after power on.31 +Each SW3L-LB is pre-load with a set of unique keys for LoRaWAN registrations, register these keys to local LoRaWAN server and it will auto connect after power on. 31 31 32 -[[image:image-2023061 3102459-3.png||height="476" width="855"]]33 +[[image:image-20230612170943-2.png||height="525" width="912"]] 33 33 34 34 35 35 == 1.2 Features == ... ... @@ -38,20 +38,17 @@ 38 38 * LoRaWAN 1.0.3 Class A 39 39 * Bands: CN470/EU433/KR920/US915/EU868/AS923/AU915/IN865 40 40 * Ultra-low power consumption 41 -* Distance Detection by Ultrasonic technology 42 -* Flat object range 30mm - 4500mm 43 -* Accuracy: ±(1cm+S*0.3%) (S: Distance) 44 -* Measure Angle: 60° 45 -* Cable Length : 25cm 42 +* Upload water flow volume 43 +* Monitor water waste 44 +* AT Commands to change parameters 45 +* supports Datalog feature 46 46 * Support Bluetooth v5.1 and LoRaWAN remote configure 47 47 * Support wireless OTA update firmware 48 -* ATCommandstohangeparameters48 +* Uplink on periodically and open/close event 49 49 * Downlink to change configure 50 -* IP66 Waterproof Enclosure 51 51 * 8500mAh Battery for long term use 52 52 53 53 54 - 55 55 == 1.3 Specification == 56 56 57 57 ... ... @@ -81,72 +81,24 @@ 81 81 * LoRa Transmit Mode: 125mA @ 20dBm, 82mA @ 14dBm 82 82 83 83 82 +== 1.4 Applications == 84 84 85 -== 1.4 Rated environmental conditions == 86 86 85 +* Flow Sensor application 86 +* Water Control 87 +* Toilet Flow Sensor 88 +* Monitor Waste water 87 87 88 -(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:500px" %) 89 -|(% style="background-color:#d9e2f3; color:#0070c0; width:163px" %)**Item**|(% style="background-color:#d9e2f3; color:#0070c0; width:90px" %)((( 90 -**Minimum value** 91 -)))|(% style="background-color:#d9e2f3; color:#0070c0; width:70px" %)((( 92 -**Typical value** 93 -)))|(% style="background-color:#d9e2f3; color:#0070c0; width:87px" %)((( 94 -**Maximum value** 95 -)))|(% style="background-color:#d9e2f3; color:#0070c0; width:40px" %)**Unit**|(% style="background-color:#d9e2f3; color:#0070c0; width:50px" %)**Remarks** 96 -|(% style="width:174px" %)Storage temperature|(% style="width:86px" %)-25|(% style="width:66px" %)25|(% style="width:90px" %)80|(% style="width:48px" %)℃|(% style="width:203px" %) 97 -|(% style="width:174px" %)Storage humidity|(% style="width:86px" %) |(% style="width:66px" %)65%|(% style="width:90px" %)90%|(% style="width:48px" %)RH|(% style="width:203px" %)(1) 98 -|(% style="width:174px" %)Operating temperature|(% style="width:86px" %)-15|(% style="width:66px" %)25|(% style="width:90px" %)60|(% style="width:48px" %)℃|(% style="width:203px" %) 99 -|(% style="width:174px" %)Working humidity|(% style="width:86px" %)((( 100 - 101 101 102 - 103 -)))|(% style="width:66px" %)65%|(% style="width:90px" %)80%|(% style="width:48px" %)RH|(% style="width:203px" %)(1) 91 +== 1.5 Sleep mode and working mode == 104 104 105 -((( 106 -(% style="color:red" %)**Remarks: (1) a. When the ambient temperature is 0-39 ℃, the maximum humidity is 90% (non-condensing); ** 107 107 108 -(% style="color:red" %)** b. When the ambient temperature is 40-50 ℃, the highest humidity is the highest humidity in the natural world at the current temperature (no condensation)** 109 - 110 - 111 -))) 112 - 113 -== 1.5 Effective measurement range Reference beam pattern == 114 - 115 - 116 -(% style="color:blue" %)**1. The tested object is a white cylindrical tube made of PVC, with a height of 100cm and a diameter of 7.5cm.** 117 - 118 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDDS75%20-%20LoRaWAN%20Distance%20Detection%20Sensor%20User%20Manual/WebHome/1654852253176-749.png?rev=1.1||alt="1654852253176-749.png"]] 119 - 120 - 121 -(% style="color:blue" %)**2. The object to be tested is a "corrugated cardboard box" perpendicular to the central axis of 0 °, and the length * width is 60cm * 50cm.** 122 - 123 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDDS75%20-%20LoRaWAN%20Distance%20Detection%20Sensor%20User%20Manual/WebHome/1654852175653-550.png?rev=1.1||alt="1654852175653-550.png"]] 124 - 125 - 126 -== 1.6 Applications == 127 - 128 - 129 -* Horizontal distance measurement 130 -* Liquid level measurement 131 -* Parking management system 132 -* Object proximity and presence detection 133 -* Intelligent trash can management system 134 -* Robot obstacle avoidance 135 -* Automatic control 136 -* Sewer 137 -* Bottom water level monitoring 138 - 139 - 140 - 141 -== 1.7 Sleep mode and working mode == 142 - 143 - 144 144 (% style="color:blue" %)**Deep Sleep Mode: **(%%)Sensor doesn't have any LoRaWAN activate. This mode is used for storage and shipping to save battery life. 145 145 146 146 (% style="color:blue" %)**Working Mode:** (%%)In this mode, Sensor will work as LoRaWAN Sensor to Join LoRaWAN network and send out sensor data to server. Between each sampling/tx/rx periodically, sensor will be in IDLE mode), in IDLE mode, sensor has the same power consumption as Deep Sleep mode. 147 147 148 148 149 -== 1. 8Button & LEDs ==99 +== 1.6 Button & LEDs == 150 150 151 151 152 152 [[image:Main.User Manual for LoRaWAN End Nodes.D20-LBD22-LBD23-LB_LoRaWAN_Temperature_Sensor_User_Manual.WebHome@1675071855856-879.png]] ... ... @@ -166,13 +166,12 @@ 166 166 |(% style="width:167px" %)Fast press ACT 5 times.|(% style="width:117px" %)Deactivate Device|(% style="width:225px" %)(% style="color:red" %)**Red led**(%%) will solid on for 5 seconds. Means device is in Deep Sleep Mode. 167 167 168 168 119 +== 1.7 BLE connection == 169 169 170 -== 1.9 BLE connection == 171 171 122 +SW3L-LB support BLE remote configure. 172 172 173 -DDS45-LB support BLE remote configure. 174 174 175 - 176 176 BLE can be used to configure the parameter of sensor or see the console output from sensor. BLE will be only activate on below case: 177 177 178 178 * Press button to send an uplink ... ... @@ -182,14 +182,27 @@ 182 182 If there is no activity connection on BLE in 60 seconds, sensor will shut down BLE module to enter low power mode. 183 183 184 184 185 -== 1. 10Pin Definitions ==134 +== 1.8 Pin Definitions == 186 186 187 187 [[image:image-20230523174230-1.png]] 188 188 189 189 190 -== 1. 11Mechanical==139 +== 1.9 Flow Sensor Spec == 191 191 192 192 142 +((( 143 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:510px" %) 144 +|=(% style="width: 80px;background-color:#D9E2F3;color:#0070C0" %)**Model**|=(% style="width: 80px;background-color:#D9E2F3;color:#0070C0" %)**Probe**|=(% style="width: 80px;background-color:#D9E2F3;color:#0070C0" %)**Diameter**|=(% style="width: 80px;background-color:#D9E2F3;color:#0070C0" %)**Range**|=(% style="width: 80px;background-color:#D9E2F3;color:#0070C0" %)**Max Pressure**|=(% style="width: 110px;background-color:#D9E2F3;color:#0070C0" %)**Measure** 145 +|(% style="width:88px" %)SW3L-004|(% style="width:75px" %)DW-004|(% style="width:107px" %)G1/2" /DN15|(% style="width:101px" %)1~~30L/min|(% style="width:116px" %)≤ 2.0Mpa|(% style="width:124px" %)450 pulse = 1 L 146 +|(% style="width:88px" %)SW3L-006|(% style="width:75px" %)DW-006|(% style="width:107px" %)G3/4" /DN20|(% style="width:101px" %)1~~60L/min|(% style="width:116px" %)≤ 1.2Mpa|(% style="width:124px" %)390 pulse = 1 L 147 +|(% style="width:88px" %)SW3L-010|(% style="width:75px" %)DW-010|(% style="width:107px" %)G 1" /DN25|(% style="width:101px" %)2~~100L/min|(% style="width:116px" %)≤ 2.0Mpa|(% style="width:124px" %)64 pulse = 1 L 148 +))) 149 + 150 + 151 + 152 +== 2.10 Mechanical == 153 + 154 + 193 193 [[image:Main.User Manual for LoRaWAN End Nodes.D20-LBD22-LBD23-LB_LoRaWAN_Temperature_Sensor_User_Manual.WebHome@1675143884058-338.png]] 194 194 195 195 ... ... @@ -199,17 +199,27 @@ 199 199 [[image:Main.User Manual for LoRaWAN End Nodes.D20-LBD22-LBD23-LB_LoRaWAN_Temperature_Sensor_User_Manual.WebHome@1675143909447-639.png]] 200 200 201 201 202 -(% style="color:blue" %)** ProbeMechanical:**164 +(% style="color:blue" %)**DW-004 Flow Sensor: diameter: G1/2” / DN15. 450 pulse = 1 L** 203 203 204 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/ LDDS45%20-%20LoRaWAN%20Distance%20Detection%20Sensor%20User%20Manual/WebHome/1654915562090-396.png?rev=1.1||alt="1654915562090-396.png"]]166 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/SW3L%20LoRaWAN%20Outdoor%20Flow%20Sensor/WebHome/image-20220519091350-1.png?width=722&height=385&rev=1.1||alt="image-20220519091350-1.png"]] 205 205 206 206 207 - =2. Configure DDS45-LBtoconnecttoLoRaWANnetwork=169 +(% style="color:blue" %)**006: DW-006 Flow Sensor: diameter: G3/4” / DN20. 390 pulse = 1 L** 208 208 171 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/SW3L%20LoRaWAN%20Outdoor%20Flow%20Sensor/WebHome/image-20220519091423-2.png?width=723&height=258&rev=1.1||alt="image-20220519091423-2.png"]] 172 + 173 + 174 +(% style="color:blue" %)**010: DW-010 Flow Sensor: diameter: G 1” / DN25. 64 pulse = 1 L** 175 + 176 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/SW3L%20LoRaWAN%20Outdoor%20Flow%20Sensor/WebHome/image-20220519091423-3.png?width=724&height=448&rev=1.1||alt="image-20220519091423-3.png"]] 177 + 178 + 179 += 2. Configure SW3L-LB to connect to LoRaWAN network = 180 + 209 209 == 2.1 How it works == 210 210 211 211 212 -The DDS45-LB is configured as (% style="color:#037691" %)**LoRaWAN OTAA Class A**(%%) mode by default. It has OTAA keys to join LoRaWAN network. To connect a local LoRaWAN network, you need to input the OTAA keys in the LoRaWAN IoT server and press the button to activate theDDS45-LB. It will automatically join the network via OTAA and start to send the sensor value. The default uplink interval is 20 minutes.184 +The SW3L-LB is configured as (% style="color:#037691" %)**LoRaWAN OTAA Class A**(%%) mode by default. It has OTAA keys to join LoRaWAN network. To connect a local LoRaWAN network, you need to input the OTAA keys in the LoRaWAN IoT server and press the button to activate the SW3L-LB. It will automatically join the network via OTAA and start to send the sensor value. The default uplink interval is 20 minutes. 213 213 214 214 (% style="display:none" %) (%%) 215 215 ... ... @@ -220,12 +220,12 @@ 220 220 221 221 The LPS8v2 is already set to connected to [[TTN network >>url:https://console.cloud.thethings.network/]], so what we need to now is configure the TTN server. 222 222 223 -[[image:image-2023061 3102426-2.png||height="476" width="855"]](% style="display:none" %)195 +[[image:image-20230612171032-3.png||height="492" width="855"]](% style="display:none" %) 224 224 225 225 226 -(% style="color:blue" %)**Step 1:**(%%) Create a device in TTN with the OTAA keys from DDS45-LB.198 +(% style="color:blue" %)**Step 1:**(%%) Create a device in TTN with the OTAA keys from SW3L-LB. 227 227 228 -Each DDS45-LB is shipped with a sticker with the default device EUI as below:200 +Each SW3L-LB is shipped with a sticker with the default device EUI as below: 229 229 230 230 [[image:image-20230426084152-1.png||alt="图片-20230426084152-1.png" height="233" width="502"]] 231 231 ... ... @@ -254,10 +254,10 @@ 254 254 [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LSN50v2-S31-S31B%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20User%20Manual/WebHome/image-20220611161308-6.png?width=744&height=485&rev=1.1||alt="图片-20220611161308-6.png"]] 255 255 256 256 257 -(% style="color:blue" %)**Step 2:**(%%) Activate on DDS45-LB229 +(% style="color:blue" %)**Step 2:**(%%) Activate on SW3L-LB 258 258 259 259 260 -Press the button for 5 seconds to activate the DDS45-LB.232 +Press the button for 5 seconds to activate the SW3L-LB. 261 261 262 262 (% style="color:green" %)**Green led**(%%) will fast blink 5 times, device will enter (% style="color:blue" %)**OTA mode**(%%) for 3 seconds. And then start to JOIN LoRaWAN network. (% style="color:green" %)**Green led**(%%) will solidly turn on for 5 seconds after joined in network. 263 263 ... ... @@ -264,168 +264,355 @@ 264 264 After join success, it will start to upload messages to TTN and you can see the messages in the panel. 265 265 266 266 267 -== 2.3 239 +== 2.3 Uplink Payload == 268 268 241 +=== 2.3.1 Device Status, FPORT~=5 === 269 269 270 -((( 271 -DDS45-LB will uplink payload via LoRaWAN with below payload format: 272 -))) 273 273 274 -((( 275 -Uplink payload includes in total 8 bytes. 276 -))) 244 +Include device configure status. Once SW3L-LB Joined the network, it will uplink this message to the server. After that, SW3L-LB will uplink Device Status every 12 hours. 277 277 278 -(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:510px" %) 279 -|=(% style="width: 62.5px;background-color:#D9E2F3;color:#0070C0" %)((( 280 -**Size(bytes)** 281 -)))|=(% style="width: 62.5px;background-color:#D9E2F3;color:#0070C0" %)**2**|=(% style="background-color:#D9E2F3;color:#0070C0" %)**2**|=(% style="background-color:#D9E2F3;color:#0070C0" %)1|=(% style="background-color:#D9E2F3;color:#0070C0" %)2|=(% style="background-color:#D9E2F3;color:#0070C0" %)**1** 282 -|(% style="width:62.5px" %)**Value**|(% style="width:62.5px" %)[[BAT>>||anchor="H2.3.1A0BatteryInfo"]]|((( 283 -[[Distance>>||anchor="H2.3.2A0Distance"]] 284 -(unit: mm) 285 -)))|[[Digital Interrupt (Optional)>>||anchor="H2.3.3A0InterruptPin"]]|((( 286 -[[Temperature (Optional )>>||anchor="H2.3.4A0DS18B20Temperaturesensor"]] 287 -)))|[[Sensor Flag>>||anchor="H2.3.5A0SensorFlag"]] 246 +Users can use the downlink command(**0x26 01**) to ask SW3L-LB to send device configure detail, include device configure status. SW3L-LB will uplink a payload via FPort=5 to server. 288 288 289 - [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDDS75%20-%20LoRaWAN%20Distance%20Detection%20Sensor%20User%20Manual/WebHome/1654850511545-399.png?rev=1.1||alt="1654850511545-399.png"]]248 +The Payload format is as below. 290 290 291 291 292 -=== 2.3.1 Battery Info === 251 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %) 252 +|(% colspan="6" style="background-color:#d9e2f3; color:#0070c0" %)**Device Status (FPORT=5)** 253 +|(% style="width:103px" %)**Size (bytes)**|(% style="width:72px" %)**1**|**2**|(% style="width:91px" %)**1**|(% style="width:86px" %)**1**|(% style="width:44px" %)**2** 254 +|(% style="width:103px" %)**Value**|(% style="width:72px" %)Sensor Model|Firmware Version|(% style="width:91px" %)Frequency Band|(% style="width:86px" %)Sub-band|(% style="width:44px" %)BAT 293 293 256 +Example parse in TTNv3 294 294 295 - Check the battery voltageDDS45-LB.258 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/SW3L%20LoRaWAN%20Outdoor%20Flow%20Sensor/WebHome/1652925144491-755.png?width=732&height=139&rev=1.1||alt="1652925144491-755.png"]] 296 296 260 + 261 +(% style="color:#037691" %)**Sensor Model**(%%): For SW3L-LB, this value is 0x11 262 + 263 +(% style="color:#037691" %)**Firmware Version**(%%): 0x0100, Means: v1.0.0 version 264 + 265 +(% style="color:#037691" %)**Frequency Band**: 266 + 267 +*0x01: EU868 268 + 269 +*0x02: US915 270 + 271 +*0x03: IN865 272 + 273 +*0x04: AU915 274 + 275 +*0x05: KZ865 276 + 277 +*0x06: RU864 278 + 279 +*0x07: AS923 280 + 281 +*0x08: AS923-1 282 + 283 +*0x09: AS923-2 284 + 285 +*0x0a: AS923-3 286 + 287 +*0x0b: CN470 288 + 289 +*0x0c: EU433 290 + 291 +*0x0d: KR920 292 + 293 +*0x0e: MA869 294 + 295 + 296 +(% style="color:#037691" %)**Sub-Band**: 297 + 298 +AU915 and US915:value 0x00 ~~ 0x08 299 + 300 +CN470: value 0x0B ~~ 0x0C 301 + 302 +Other Bands: Always 0x00 303 + 304 + 305 +(% style="color:#037691" %)**Battery Info**: 306 + 307 +Check the battery voltage. 308 + 297 297 Ex1: 0x0B45 = 2885mV 298 298 299 299 Ex2: 0x0B49 = 2889mV 300 300 301 301 302 -=== 2.3.2 Distance===314 +=== 2.3.2 Sensor Configuration, FPORT~=4 === 303 303 304 304 317 +SW3L-LB will only send this command after getting the downlink command (0x26 02) from the server. 318 + 319 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:510px" %) 320 +|(% style="background-color:#d9e2f3; color:#0070c0; width:70px" %) **Size(bytes)**|(% style="background-color:#d9e2f3; color:#0070c0; width:105px" %)**3**|(% style="background-color:#d9e2f3; color:#0070c0; width:60px" %)**1**|(% style="background-color:#d9e2f3; color:#0070c0; width:96px" %)**1**|(% style="background-color:#d9e2f3; color:#0070c0; width:105px" %)**2**|(% style="background-color:#d9e2f3; color:#0070c0; width:74px" %)**1** 321 +|**Value**|(% style="width:104px" %)TDC(unit:sec)|(% style="width:43px" %)N/A|(% style="width:91px" %)Stop Timer|(% style="width:100px" %)Alarm Timer|(% style="width:69px" %)Reserve 322 + 323 +* (% style="color:#037691" %)**TDC: (default: 0x0004B0)** 324 + 325 +Uplink interval for the total pulse count, default value is 0x0004B0 which is 1200 seconds = 20 minutes. 326 + 327 + 328 +* (% style="color:#037691" %)**STOP Duration & Alarm Timer** 329 + 330 +Shows the configure value of [[Alarm for continuously water flow>>||anchor="H3.3.4Alarmforcontinuouslywaterflow"]] 331 + 332 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/SW3L%20LoRaWAN%20Outdoor%20Flow%20Sensor/WebHome/image-20220519095747-2.png?width=723&height=113&rev=1.1||alt="image-20220519095747-2.png"]] 333 + 334 + 335 +=== 2.3.3 Water Flow Value, Uplink FPORT~=2 === 336 + 337 + 305 305 ((( 306 - Getthe distance.Flat objectrange30mm-4500mm.339 +SW3L-LB will send this uplink **after** Device Status once join the LoRaWAN network successfully. And SW3L-LB will: 307 307 ))) 308 308 309 309 ((( 310 -For example, if the data you get from the register is **0x0B 0x05**, the distance between the sensor and the measured object is(% style="color:#4472c4" %)** ** 343 +periodically send this uplink every 20 minutes, this interval [[can be changed>>||anchor="H3.3.1SetTransmitIntervalTime"]]. 344 +))) 311 311 312 -(% style="color:blue" %)**0B05(H) = 2821 (D) = 2821 mm.** 346 +((( 347 +Uplink Payload totals 11 bytes. 313 313 ))) 314 314 350 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:510px" %) 351 +|=(% colspan="6" style="width: 510px;background-color:#D9E2F3;color:#0070C0" %)**Water Flow Value, FPORT=2** 352 +|(% style="width:60px" %)**Size(bytes)**|(% style="width:130px" %)**1**|(% style="width:130px" %)**4**|(% style="width:30px" %)**1**|(% style="width:50px" %)**1**|(% style="width:80px" %)**4** 353 +|(% style="width:110px" %)**Value**|(% style="width:81px" %)Calculate Flag & [[Alarm>>||anchor="H3.3.4Alarmforcontinuouslywaterflow"]]|(% style="width:95px" %)((( 354 +Total pulse Or Last Pulse 355 +)))|(% style="width:55px" %)MOD|(% style="width:115px" %)Reserve(0x01)|(% style="width:129px" %)[[Unix TimeStamp>>||anchor="H2.5.2UnixTimeStamp"]] 315 315 316 -* If the sensor value is 0x0000, it means system doesn't detect ultrasonic sensor. 317 -* If the sensor value lower than 0x001E (30mm), the sensor value will be 0x00. 357 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:470px" %) 358 +|=(% colspan="4" style="width: 470px;background-color:#D9E2F3;color:#0070C0" %)**Status & Alarm field** 359 +|(% style="width:60px" %)**Size(bit)**|(% style="width:80px" %)**6**|(% style="width:310px" %)**1**|(% style="width:20px" %)**1** 360 +|(% style="width:88px" %)**Value**|(% style="width:117px" %)Calculate Flag|(% style="width:221px" %)Alarm: 0: No Alarm; 1: Alarm|(% style="width:64px" %)N/A 318 318 362 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/SW3L%20LoRaWAN%20Outdoor%20Flow%20Sensor/WebHome/image-20220519095946-3.png?width=736&height=284&rev=1.1||alt="image-20220519095946-3.png"]] 319 319 320 320 321 -=== 2.3.3 Interrupt Pin === 365 +* ((( 366 +(% style="color:#037691" %)**Calculate Flag** 367 +))) 322 322 369 +((( 370 +The calculate flag is a user defined field, IoT server can use this flag to handle different meters with different pulse factors. For example, if there are 100 Flow Sensors, meters 1 ~~50 are 1 liter/pulse and meters 51 ~~ 100 has 1.5 liter/pulse. 371 +))) 323 323 324 -This data field shows if this packet is generated by interrupt or not. [[Click here>>||anchor="H3.3.2SetInterruptMode"]] for the hardware and software set up. 373 +((( 374 +**Example: in the default payload:** 375 +))) 325 325 326 -**Example:** 377 +* ((( 378 +calculate flag=0: for SW3L-004 Flow Sensor: 450 pulse = 1 L 379 +))) 380 +* ((( 381 +calculate flag=1: for SW3L-006 Flow Sensor: 390 pulse = 1 L 382 +))) 383 +* ((( 384 +calculate flag=2: for SW3L-010 Flow Sensor: 64 pulse = 1 L 385 +))) 327 327 328 -0x00: Normal uplink packet. 387 +((( 388 +Default value: 0. 389 +))) 329 329 330 -0x01: Interrupt Uplink Packet. 391 +((( 392 +Range (6 bits): (b)000000 ~~ (b) 111111 331 331 394 +If user use with a meter for example is 0.02L/pulse. To proper decode the correct value in server, 332 332 333 - === 2.3.4 DS18B20Temperature sensor===396 +1) User can set the Calculate Flag of this sensor to 3. 334 334 398 +2) In server side, when a sensor data arrive, the decoder will check the value of Calculate Flag, It the value is 3, the total volume = 0.02 x Pulse Count. 399 +))) 335 335 336 -This is optional, user can connect external DS18B20 sensor to the +3.3v, 1-wire and GND pin . and this field will report temperature. 401 +((( 402 +(% style="color:red" %)**NOTE: User need to set Calculate Flag to proper value before use Flow Sensor. Downlink or AT Command see: **(%%)Refer: [[Set Calculate Flag>>||anchor="H3.3.6Setthecalculateflag"]] 403 +))) 337 337 338 -**Example**: 405 +* ((( 406 +(% style="color:#037691" %)**Alarm** 407 +))) 339 339 340 -If payload is: 0105H: (0105 & FC00 == 0), temp = 0105H /10 = 26.1 degree 409 +((( 410 +See [[Alarm for continuously water flow>>||anchor="H3.3.4Alarmforcontinuouslywaterflow"]] 411 +))) 341 341 342 - Ifpayload: FF3FH : (FF3F & FC00== 1) ,temp = (FF3FH65536)/10= -19.3degrees.413 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/SW3L%20LoRaWAN%20Outdoor%20Flow%20Sensor/WebHome/image-20220519095946-4.png?width=724&height=65&rev=1.1||alt="image-20220519095946-4.png"]] 343 343 344 344 345 -=== 2.3.5 Sensor Flag === 416 +* ((( 417 +(% style="color:#037691" %)**Total pulse** 418 +))) 346 346 420 +((( 421 +Total pulse/counting since factory 422 +))) 347 347 348 348 ((( 349 - 0x01: Detect UltrasonicSensor425 +Range (4 Bytes) : 0x00000000~~ 0xFFFFFFFF . 350 350 ))) 351 351 428 +* ((( 429 +(% style="color:#037691" %)**Last Pulse** 430 +))) 431 + 352 352 ((( 353 - 0x00: NoUltrasonicSensor433 +Total pulse since last FPORT=2 uplink. (Default 20 minutes) 354 354 ))) 355 355 436 +((( 437 +Range (4 Bytes) : 0x00000000~~ 0xFFFFFFFF . 438 +))) 356 356 357 -=== 2.3.6 Decode payload in The Things Network === 440 +* ((( 441 +(% style="color:#037691" %)**MOD: Default =0** 442 +))) 358 358 444 +((( 445 +MOD=0 ~-~-> Uplink Total Pulse since factory 446 +))) 359 359 360 -While using TTN network, you can add the payload format to decode the payload. 448 +((( 449 +MOD=1 ~-~-> Uplink total pulse since last FPORT=2 uplink. 450 +))) 361 361 362 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDDS75%20-%20LoRaWAN%20Distance%20Detection%20Sensor%20User%20Manual/WebHome/1654850829385-439.png?rev=1.1||alt="1654850829385-439.png"]] 452 +* ((( 453 +(% style="color:#037691" %)**Water Flow Value** 454 +))) 363 363 364 -The payload decoder function for TTN V3 is here: 456 +((( 457 +**Total Water Flow Volume = (Calculate Flag) x (Total Pulse)=9597/450=21.3L** 458 +))) 365 365 460 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/SW3L%20LoRaWAN%20Outdoor%20Flow%20Sensor/WebHome/image-20220519095946-5.png?width=727&height=50&rev=1.1||alt="image-20220519095946-5.png"]] 461 + 462 + 366 366 ((( 367 - DDS45-LBTTNV3 PayloadDecoder: [[ttps:~~/~~/github.com/dragino/dragino-end-node-decoder>>https://github.com/dragino/dragino-end-node-decoder]]464 +**Total Water Flow for TDC timer = (Calculate Flag) x (Last Pulse)=79/450=0.2L** 368 368 ))) 369 369 467 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/SW3L%20LoRaWAN%20Outdoor%20Flow%20Sensor/WebHome/image-20220519095946-6.png?width=733&height=43&rev=1.1||alt="image-20220519095946-6.png"]] ** ** 370 370 371 -== 2.4 Uplink Interval == 372 372 470 +=== 2.3.4 Historical Water Flow Status, FPORT~=3 === 373 373 374 -The DDS45-LB by default uplink the sensor data every 20 minutes. User can change this interval by AT Command or LoRaWAN Downlink Command. See this link: [[Change Uplink Interval>>||anchor="H3.3.1SetTransmitIntervalTime"]] 375 375 473 +((( 474 +SW3L-LB stores sensor values and users can retrieve these history values via the [[downlink command>>||anchor="H2.5DatalogFeature"]]. 475 +))) 376 376 377 -== 2.5 Show Data in DataCake IoT Server == 477 +((( 478 +The historical payload includes one or multiplies entries and every entry has the same payload as Real-Time water flow status. 479 +))) 378 378 481 +* ((( 482 +Each data entry is 11 bytes and has the same structure as [[real time water flow status>>||anchor="H2.3.3A0WaterFlowValue2CUplinkFPORT3D2"]], to save airtime and battery, SW3L will send max bytes according to the current DR and Frequency bands. 483 +))) 379 379 380 380 ((( 381 - [[DATACAKE>>url:https://datacake.co/]] providesahuman friendlyinterfaceto show thesensordata, once we havedata in TTN,wecanuse [[DATACAKE>>url:https://datacake.co/]] to connect to TTNandseethedatain DATACAKE. Below arehesteps:486 +For example, in the US915 band, the max payload for different DR is: 382 382 ))) 383 383 489 +((( 490 +(% style="color:blue" %)**a) DR0:**(%%) max is 11 bytes so one entry of data 491 +))) 384 384 385 385 ((( 386 -(% style="color:blue" %)** Step1**(%%)**:Besurethatyourdevice isprogrammedandproperly connectedto thenetwork atthistime.**494 +(% style="color:blue" %)**b) DR1:**(%%) max is 53 bytes so devices will upload 4 entries of data (total 44 bytes) 387 387 ))) 388 388 389 389 ((( 390 -(% style="color:blue" %)** Step2**(%%)**:To configurethe Applicationto forwarddata to DATACAKEyou will need todintegration. To add theDATACAKEintegration, performthe followingsteps:**498 +(% style="color:blue" %)**c) DR2:**(%%) total payload includes 11 entries of data 391 391 ))) 392 392 501 +((( 502 +(% style="color:blue" %)**d) DR3:**(%%) total payload includes 22 entries of data. 503 +))) 393 393 394 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDDS75%20-%20LoRaWAN%20Distance%20Detection%20Sensor%20User%20Manual/WebHome/1654592790040-760.png?rev=1.1||alt="1654592790040-760.png"]] 505 +((( 506 +If SW3L-LB doesn't have any data in the polling time. It will uplink 11 bytes of 0 507 +))) 395 395 509 +((( 510 +(% style="color:#037691" %)**Downlink:** 511 +))) 396 396 397 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDDS75%20-%20LoRaWAN%20Distance%20Detection%20Sensor%20User%20Manual/WebHome/1654592800389-571.png?rev=1.1||alt="1654592800389-571.png"]] 513 +((( 514 +0x31 62 46 B1 F0 62 46 B3 94 07 515 +))) 398 398 517 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/SW3L%20LoRaWAN%20Outdoor%20Flow%20Sensor/WebHome/1652926690850-712.png?width=726&height=115&rev=1.1||alt="1652926690850-712.png"]] 399 399 400 -(% style="color:blue" %)**Step 3**(%%)**: Create an account or log in Datacake.** 401 401 402 -(% style="color:blue" %)**Step 4**(%%)**: Search the DDS45-LB and add DevEUI.** 520 +((( 521 +(% style="color:#037691" %)**Uplink:** 522 +))) 403 403 404 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDDS75%20-%20LoRaWAN%20Distance%20Detection%20Sensor%20User%20Manual/WebHome/1654851029373-510.png?rev=1.1||alt="1654851029373-510.png"]] 524 +((( 525 +00 00 01 00 00 00 00 62 46 B2 26 00 00 01 00 00 00 00 62 46 B2 5D 00 00 01 00 00 00 00 62 46 B2 99 00 00 01 00 00 00 00 62 46 B2 D5 00 00 01 00 00 01 15 62 46 B3 11 00 00 01 00 00 01 1F 62 46 B3 7E 526 +))) 405 405 528 +((( 529 +(% style="color:#037691" %)**Parsed Value:** 530 +))) 406 406 407 -After added, the sensor data arrive TTN V3, it will also arrive and show in Datacake. 532 +((( 533 +[Alarm, Calculate Flag, MOD, Total pulse or Last Pulse,** **Water Flow Value, TIME] 534 +))) 408 408 409 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDDS75%20-%20LoRaWAN%20Distance%20Detection%20Sensor%20User%20Manual/WebHome/image-20220610165129-11.png?width=1088&height=595&rev=1.1||alt="image-20220610165129-11.png"]] 410 410 537 +((( 538 +[FALSE,0,0,0,0.0,2022-04-01 08:04:54], 539 +))) 411 411 541 +((( 542 +[FALSE,0,0,0,0.0,2022-04-01 08:05:49], 543 +))) 412 412 413 -== 2.6 Datalog Feature == 545 +((( 546 +[FALSE,0,0,0,0.0,2022-04-01 08:06:49], 547 +))) 414 414 549 +((( 550 +[FALSE,0,0,0,0.0,2022-04-01 08:07:49], 551 +))) 415 415 416 -Datalog Feature is to ensure IoT Server can get all sampling data from Sensor even if the LoRaWAN network is down. For each sampling, DDS45-LB will store the reading for future retrieving purposes. 553 +((( 554 +[FALSE,0,0,277,0.6,2022-04-01 08:08:49], 555 +))) 417 417 557 +((( 558 +[FALSE,0,0,287,0.6,2022-04-01 08:10:38], 559 +))) 418 418 419 - === 2.6.1 Ways togettalog via561 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/SW3L%20LoRaWAN%20Outdoor%20Flow%20Sensor/WebHome/1652926777796-267.png?width=724&height=279&rev=1.1||alt="1652926777796-267.png"]] 420 420 421 421 422 - Set PNACKMD=1,DDS45-LBwill wait for ACK for everyuplink, when there is noLoRaWANnetwork,DDS45-LB will mark these records with non-ack messages and storethe sensor data, andit will sendall messages (10s interval) after the network recovery.564 +== 2.4 Payload Decoder file == 423 423 566 + 567 +In TTN, use can add a custom payload so it shows friendly reading 568 + 569 +In the page (% style="color:#037691" %)**Applications ~-~-> Payload Formats ~-~-> Custom ~-~-> decoder**(%%) to add the decoder from: [[https:~~/~~/github.com/dragino/dragino-end-node-decoder>>https://github.com/dragino/dragino-end-node-decoder]] 570 + 571 + 572 +== 2.5 Datalog Feature == 573 + 574 + 575 +Datalog Feature is to ensure IoT Server can get all sampling data from Sensor even if the LoRaWAN network is down. For each sampling, SW3L-LB will store the reading for future retrieving purposes. 576 + 577 + 578 +=== 2.5.1 Ways to get datalog via LoRaWAN === 579 + 580 + 581 +Set PNACKMD=1, SW3L-LB will wait for ACK for every uplink, when there is no LoRaWAN network,SW3L-LB will mark these records with non-ack messages and store the sensor data, and it will send all messages (10s interval) after the network recovery. 582 + 424 424 * ((( 425 -a) DDS45-LB will do an ACK check for data records sending to make sure every data arrive server.584 +a) SW3L-LB will do an ACK check for data records sending to make sure every data arrive server. 426 426 ))) 427 427 * ((( 428 -b) DDS45-LB will send data in **CONFIRMED Mode** when PNACKMD=1, butDDS45-LB won't re-transmit the packet if it doesn't get ACK, it will just mark it as a NONE-ACK message. In a future uplink ifDDS45-LB gets a ACK,DDS45-LB will consider there is a network connection and resend all NONE-ACK messages.587 +b) SW3L-LB will send data in **CONFIRMED Mode** when PNACKMD=1, but SW3L-LB won't re-transmit the packet if it doesn't get ACK, it will just mark it as a NONE-ACK message. In a future uplink if SW3L-LB gets a ACK, SW3L-LB will consider there is a network connection and resend all NONE-ACK messages. 429 429 ))) 430 430 431 431 Below is the typical case for the auto-update datalog feature (Set PNACKMD=1) ... ... @@ -433,10 +433,10 @@ 433 433 [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/WebHome/image-20220703111700-2.png?width=1119&height=381&rev=1.1||alt="图片-20220703111700-2.png" height="381" width="1119"]] 434 434 435 435 436 -=== 2. 6.2 Unix TimeStamp ===595 +=== 2.5.2 Unix TimeStamp === 437 437 438 438 439 - DDS45-LB uses Unix TimeStamp format based on598 +SW3L-LB uses Unix TimeStamp format based on 440 440 441 441 [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/WebHome/image-20220523001219-11.png?width=627&height=97&rev=1.1||alt="图片-20220523001219-11.png" height="97" width="627"]] 442 442 ... ... @@ -450,17 +450,17 @@ 450 450 So, we can use AT+TIMESTAMP=1611889405 or downlink 3060137afd00 to set the current time 2021 – Jan ~-~- 29 Friday 03:03:25 451 451 452 452 453 -=== 2. 6.3 Set Device Time ===612 +=== 2.5.3 Set Device Time === 454 454 455 455 456 456 User need to set (% style="color:blue" %)**SYNCMOD=1**(%%) to enable sync time via MAC command. 457 457 458 -Once DDS45-LB Joined LoRaWAN network, it will send the MAC command (DeviceTimeReq) and the server will reply with (DeviceTimeAns) to send the current time toDDS45-LB. IfDDS45-LB fails to get the time from the server,DDS45-LB will use the internal time and wait for next time request (AT+SYNCTDC to set the time request period, default is 10 days).617 +Once SW3L-LB Joined LoRaWAN network, it will send the MAC command (DeviceTimeReq) and the server will reply with (DeviceTimeAns) to send the current time to SW3L-LB. If SW3L-LB fails to get the time from the server, SW3L-LB will use the internal time and wait for next time request (AT+SYNCTDC to set the time request period, default is 10 days). 459 459 460 460 (% style="color:red" %)**Note: LoRaWAN Server need to support LoRaWAN v1.0.3(MAC v1.0.3) or higher to support this MAC command feature, Chirpstack,TTN V3 v3 and loriot support but TTN V3 v2 doesn't support. If server doesn't support this command, it will through away uplink packet with this command, so user will lose the packet with time request for TTN V3 v2 if SYNCMOD=1.** 461 461 462 462 463 -=== 2. 6.4 Poll sensor value ===622 +=== 2.5.4 Poll sensor value === 464 464 465 465 466 466 Users can poll sensor values based on timestamps. Below is the downlink command. ... ... @@ -483,24 +483,24 @@ 483 483 ))) 484 484 485 485 ((( 486 -Uplink Internal =5s,means DDS45-LB will send one packet every 5s. range 5~~255s.645 +Uplink Internal =5s,means SW3L-LB will send one packet every 5s. range 5~~255s. 487 487 ))) 488 488 489 489 490 -== 2. 7Frequency Plans ==649 +== 2.6 Frequency Plans == 491 491 492 492 493 -The DDS45-LB uses OTAA mode and below frequency plans by default. If user want to use it with different frequency plan, please refer the AT command sets.652 +The SW3L-LB uses OTAA mode and below frequency plans by default. If user want to use it with different frequency plan, please refer the AT command sets. 494 494 495 495 [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20Frequency%20Band/>>http://wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20Frequency%20Band/]] 496 496 497 497 498 -= 3. Configure DDS45-LB =657 += 3. Configure SW3L-LB = 499 499 500 500 == 3.1 Configure Methods == 501 501 502 502 503 - DDS45-LB supports below configure method:662 +SW3L-LB supports below configure method: 504 504 505 505 * AT Command via Bluetooth Connection (**Recommended**): [[BLE Configure Instruction>>http://wiki.dragino.com/xwiki/bin/view/Main/BLE%20Bluetooth%20Remote%20Configure/]]. 506 506 ... ... @@ -509,7 +509,6 @@ 509 509 * LoRaWAN Downlink. Instruction for different platforms: See [[IoT LoRaWAN Server>>http://wiki.dragino.com/xwiki/bin/view/Main/]] section. 510 510 511 511 512 - 513 513 == 3.2 General Commands == 514 514 515 515 ... ... @@ -524,10 +524,10 @@ 524 524 [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/>>http://wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/]] 525 525 526 526 527 -== 3.3 Commands special design for DDS45-LB ==685 +== 3.3 Commands special design for SW3L-LB == 528 528 529 529 530 -These commands only valid for DDS45-LB, as below:688 +These commands only valid for SW3L-LB, as below: 531 531 532 532 533 533 === 3.3.1 Set Transmit Interval Time === ... ... @@ -569,143 +569,268 @@ 569 569 Example 1: Downlink Payload: 0100001E ~/~/ Set Transmit Interval (TDC) = 30 seconds 570 570 ))) 571 571 * ((( 572 -Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds 730 +Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds 573 573 ))) 574 574 575 575 734 +=== 3.3.2 Quit AT Command === 576 576 577 -=== 3.3.2 Set Interrupt Mode === 578 578 737 +Feature: Quit AT Command mode, so user needs to input the password again before using AT Commands. 579 579 580 - Feature,SetInterrupt modefor PA8of pin.739 +(% style="color:blue" %)**AT Command: AT+DISAT** 581 581 582 -When AT+INTMOD=0 is set, PA8 is used as a digital input port. 741 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:452px" %) 742 +|=(% style="width: 155px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 198px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 99px;background-color:#D9E2F3;color:#0070C0" %)**Response** 743 +|(% style="width:155px" %)AT+DISAT|(% style="width:198px" %)Quit AT Commands mode|(% style="width:96px" %)OK 583 583 584 -(% style="color:blue" %)** ATCommand:AT+INTMOD**745 +(% style="color:blue" %)**Downlink Command:** 585 585 586 -(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %) 587 -|=(% style="width: 155px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 197px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 158px;background-color:#D9E2F3;color:#0070C0" %)**Response** 588 -|(% style="width:154px" %)AT+INTMOD=?|(% style="width:196px" %)Show current interrupt mode|(% style="width:157px" %)((( 589 -0 590 -OK 591 -the mode is 0 =Disable Interrupt 747 +No downlink command for this feature. 748 + 749 + 750 +=== 3.3.3 Get Device Status === 751 + 752 + 753 +Send a LoRaWAN downlink to ask device send Alarm settings. 754 + 755 +(% style="color:blue" %)**Downlink Payload: **(%%)0x26 01 756 + 757 +Sensor will upload Device Status via FPORT=5. See payload section for detail. 758 + 759 + 760 +=== 3.3.4 Alarm for continuously water flow === 761 + 762 + 763 +((( 764 +This feature is to monitor and send Alarm for continuously water flow. 592 592 ))) 593 -|(% style="width:154px" %)AT+INTMOD=2|(% style="width:196px" %)((( 594 -Set Transmit Interval 595 -0. (Disable Interrupt), 596 -~1. (Trigger by rising and falling edge) 597 -2. (Trigger by falling edge) 598 -3. (Trigger by rising edge) 599 -)))|(% style="width:157px" %)OK 600 600 601 -(% style="color:blue" %)**Downlink Command: 0x06** 767 +((( 768 +Example case is for Toilet water monitoring, if some one push toilet button, the toilet will have water flow. If the toilet button has broken and can't returned to original state, the water flow will keep for hours or days which cause huge waste for water. 769 +))) 602 602 603 -Format: Command Code (0x06) followed by 3 bytes. 771 +((( 772 +To monitor this faulty and send alarm, there are two settings: 773 +))) 604 604 605 -This means that the interrupt mode of the end node is set to 0x000003=3 (rising edge trigger), and the type code is 06. 775 +* ((( 776 +(% style="color:#4f81bd" %)**Stop Duration: Unit: Second** 777 +))) 606 606 607 -* Example 1: Downlink Payload: 06000000 ~/~/ Turn off interrupt mode 779 +((( 780 +Default: 15s, If SW3L-LB didn't see any water flow in 15s, SW3L-LB will consider stop of water flow event. 781 +))) 608 608 609 -* Example 2: Downlink Payload: 06000003 ~/~/ Set the interrupt mode to rising edge trigger 783 +* ((( 784 +(% style="color:#4f81bd" %)**Alarm Timer: Units: Minute; Default 0 minutes (means Alarm disable)** 785 +))) 610 610 787 +((( 788 +**Example:** 3 minutes, if SW3L-LB detect a start of water flow event and didn't detect a stop event within Alarm timer, SW3L-LB will send an Alarm to indicate a water flow abnormal alarm. 789 +))) 611 611 791 +((( 792 +So for example, If we set stop duration=15s and Alarm Timer=3minutes. If the toilet water flow continuously for more than 3 minutes, Sensor will send an alarm (in Confirmed MODE) to platform. 793 +))) 612 612 613 -= 4. Battery & Power Consumption = 795 +((( 796 +(% style="color:red" %)**Note:** **After this alarm is send, sensor will consider a stop of water flow and count for another new event. So if water flow waste last for 1 hour, Sensor will keep sending alarm every 3 minutes.** 797 +))) 614 614 799 +((( 800 +(% style="color:#4f81bd" %)**AT Command**(%%) to configure: 801 +))) 615 615 616 -DDS45-LB use ER26500 + SPC1520 battery pack. See below link for detail information about the battery info and how to replace. 803 +* ((( 804 +AT+PTRIG=15,3 ~-~-> Set Stop duration: 15s, Alarm Timer: 3 minutes. 805 +))) 617 617 618 -[[**Battery Info & Power Consumption Analyze**>>http://wiki.dragino.com/xwiki/bin/view/Main/How%20to%20calculate%20the%20battery%20life%20of%20Dragino%20sensors%3F/]] . 807 +* ((( 808 +AT+ PTRIG=15,0 ~-~-> Default Value, disable water waste Alarm. 809 +))) 619 619 811 +((( 812 +(% style="color:#4f81bd" %)**Downlink Command**(%%) to configure: 813 +))) 620 620 621 -= 5. OTA Firmware update = 815 +((( 816 +Command: **0xAA aa bb cc** 817 +))) 622 622 819 +((( 820 +AA: Command Type Code 821 +))) 623 623 624 -(% class="wikigeneratedid" %) 625 -User can change firmware DDS45-LB to: 823 +((( 824 +aa: Stop duration 825 +))) 626 626 627 -* Change Frequency band/ region. 827 +((( 828 +bb cc: Alarm Timer 829 +))) 628 628 629 -* Update with new features. 831 +((( 832 +If user send 0xAA 0F 00 03: equal to AT+PTRIG=15,3 833 +))) 630 630 631 -* Fix bugs. 632 632 633 - Firmwareandchangelog can bedownloaded from: **[[Firmware download link>>url:https://www.dropbox.com/sh/a5ue0nfrzqy9nz6/AABbvlATosDJKDwBmbirVbMYa?dl=0]]**836 +=== 3.3.5 Clear Flash Record === 634 634 635 -Methods to Update Firmware: 636 636 637 - * (Recommanded way) OTA firmwareupdateviawireless: [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/Firmware%20OTA%20Update%20for%20Sensors/>>url:http://wiki.dragino.com/xwiki/bin/view/Main/Firmware%20OTA%20Update%20for%20Sensors/]]839 +Feature: Clear flash storage for data log feature. 638 638 639 - *UpdatethroughUARTTTL interface: **[[Instruction>>url:http://wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H1.LoRaSTv4baseHardware]]**.841 +(% style="color:blue" %)**AT Command: AT+CLRDTA** 640 640 843 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:500px" %) 844 +|=(% style="width: 157px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 169px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 174px;background-color:#D9E2F3;color:#0070C0" %)**Response** 845 +|(% style="width:157px" %)AT+CLRDTA|(% style="width:169px" %)Clear flash storage for data log feature.|Clear all stored sensor data… OK 641 641 847 +((( 848 +(% style="color:blue" %)**Downlink Command:** 849 +))) 642 642 643 -= 6. FAQ = 851 +((( 852 +* **Example**: 0xA301 ~/~/ Same as AT+CLRDTA 853 +))) 644 644 645 -== 6.1 What is the frequency plan for DDS45-LB? == 646 646 647 647 648 - DDS45-LBuse thesame frequencyas other Dragino products. User can seethedetailfrom thislink: [[Introduction>>doc:Main.EndDevice Frequency Band.WebHome||anchor="H1.Introduction"]]857 +=== 3.3.6 Set the calculate flag === 649 649 650 650 651 - == 6.2 Can IuseDDS45-LBincondensationenvironment?==860 +Feature: Set the calculate flag 652 652 862 +(% style="color:blue" %)**AT Command: AT+CALCFLAG** 653 653 654 -DDS45-LB is not suitable to be used in condensation environment. Condensation on the DDS45-LB probe will affect the reading and always got 0. 864 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:461px" %) 865 +|=(% style="width: 158px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 193px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 110px;background-color:#D9E2F3;color:#0070C0" %)**Response** 866 +|(% style="width:158px" %)AT+CALCFLAG =1|(% style="width:192px" %)Set the calculate flag to 1.|(% style="width:109px" %)OK 867 +|(% style="width:158px" %)AT+CALCFLAG =2|(% style="width:192px" %)Set the calculate flag to 2.|(% style="width:109px" %)OK 655 655 869 +(% style="color:blue" %)**Downlink Command:** 656 656 657 - =7. Trouble Shooting=871 +* **Example**: 0XA501 ~/~/ Same as AT+CALCFLAG =1 658 658 659 -== 7.1 Why I can't join TTN V3 in US915 / AU915 bands? == 660 660 874 +=== 3.3.7 Set count number === 661 661 662 -It is due to channel mapping. Please see below link: [[Frequency band>>doc:Main.LoRaWAN Communication Debug.WebHome||anchor="H2.NoticeofUS9152FCN4702FAU915Frequencyband"]] 663 663 877 +Feature: Manually set the count number 664 664 665 -= =7.2AT Commandinput doesn't work ==879 +(% style="color:blue" %)**AT Command: AT+SETCNT** 666 666 881 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:479px" %) 882 +|=(% style="width: 160px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 223px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 96px;background-color:#D9E2F3;color:#0070C0" %)**Response** 883 +|(% style="width:160px" %)AT+ SETCNT =0|(% style="width:221px" %)Set the count number to 0.|(% style="width:95px" %)OK 884 +|(% style="width:160px" %)AT+ SETCNT =100|(% style="width:221px" %)Set the count number to 100.|(% style="width:95px" %)OK 667 667 668 - In the case if user can see the console output but can't type input to the device. Please check if you already include the(% style="color:blue" %)**ENTER**(%%)while sendingout the command. Some serial tool doesn't send (% style="color:blue" %)**ENTER**(%%) while press the send key, user need to add ENTER in their string.886 +(% style="color:blue" %)**Downlink Command:** 669 669 888 +* **Example**: 0xA6000001 ~/~/ Same as AT+ SETCNT =1 670 670 671 - ==7.3Whydoesthesensorreadingshow0or "Nosensor"==890 +* **Example**: 0xA6000064 ~/~/ Same as AT+ SETCNT =100 672 672 673 673 674 - ~1.Themeasurementobject is very close to the sensor, but in the blind spot of thesensor.893 +=== 3.3.8 Set Interrupt Mode === 675 675 676 -2. Sensor wiring is disconnected 677 677 678 - 3.Notusingthecorrectdecoder896 +Feature, Set Interrupt mode for PA8 of pin. 679 679 898 +When AT+INTMOD=0 is set, PA8 is used as a digital input port. 680 680 681 - ==7.4 Abnormal readingsThe gap between multiplereadings is toolargeorthe gapbetween the readings and the actualvalueistoo large==900 +(% style="color:blue" %)**AT Command: AT+INTMOD** 682 682 902 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %) 903 +|=(% style="width: 155px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 197px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 158px;background-color:#D9E2F3;color:#0070C0" %)**Response** 904 +|(% style="width:154px" %)AT+INTMOD=?|(% style="width:196px" %)Show current interrupt mode|(% style="width:157px" %)((( 905 +0 906 +OK 907 +the mode is 0 =Disable Interrupt 908 +))) 909 +|(% style="width:154px" %)AT+INTMOD=2|(% style="width:196px" %)((( 910 +Set Transmit Interval 911 +0. (Disable Interrupt), 912 +~1. (Trigger by rising and falling edge) 913 +2. (Trigger by falling edge) 914 +3. (Trigger by rising edge) 915 +)))|(% style="width:157px" %)OK 683 683 684 - 1)Please check ifthere is somethingon the probeaffectingitsmeasurement (condensedwater, volatile oil, etc.)917 +(% style="color:blue" %)**Downlink Command: 0x06** 685 685 686 - 2) Does it change withtemperature,temperaturewillaffectitsmeasurement919 +Format: Command Code (0x06) followed by 3 bytes. 687 687 688 - 3)If abnormaldataoccurs,youcanturnonDEBUG mode,PleaseusedownlinkorATCOMMANtoenterDEBUG mode.921 +This means that the interrupt mode of the end node is set to 0x000003=3 (rising edge trigger), and the type code is 06. 689 689 690 - downlinkcommand:(%style="color:blue"%)**F101**(%%),ATcommand:(% style="color:blue"%)**AT+DDEBUG=1**923 +* Example 1: Downlink Payload: 06000000 ~/~/ Turn off interrupt mode 691 691 692 - 4)Afterenteringthe debug mode,itwillsend20piecesofdataata time,andyoucan senditsuplinktous foranalysis925 +* Example 2: Downlink Payload: 06000003 ~/~/ Set the interrupt mode to rising edge trigger 693 693 694 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDDS75%20-%20LoRaWAN%20Distance%20Detection%20Sensor%20User%20Manual/WebHome/image-20230113135125-2.png?width=1057&height=136&rev=1.1||alt="image-20230113135125-2.png"]] 695 695 928 +=== 3.3.9 Set work mode === 696 696 697 -Its original payload will be longer than other data. Even though it is being parsed, it can be seen that it is abnormal data. 698 698 699 - Please sendthedata tous forcheck.931 +Feature: Manually set the work mode 700 700 701 701 702 - =8. OrderInfo=934 +(% style="color:blue" %)**AT Command: AT+MOD** 703 703 936 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:463px" %) 937 +|=(% style="width: 162px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 193px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 108px;background-color:#D9E2F3;color:#0070C0" %)**Response** 938 +|(% style="width:162px" %)AT+MOD=0|(% style="width:191px" %)Set the work mode to 0.|(% style="width:106px" %)OK 939 +|(% style="width:162px" %)AT+MOD=1|(% style="width:191px" %)Set the work mode to 1|(% style="width:106px" %)OK 704 704 705 - Part Number:(% style="color:blue" %)**DDS45-LB-XXX**941 +(% style="color:blue" %)**Downlink Command:** 706 706 707 - (%style="color:red"%)**XXX**(%%):**Thedefaultfrequencyband**943 +* **Example: **0x0A00 ~/~/ Same as AT+MOD=0 708 708 945 +* **Example:** 0x0A01 ~/~/ Same as AT+MOD=1 946 + 947 + 948 += 4. Battery & Power Consumption = 949 + 950 + 951 +SW3L-LB use ER26500 + SPC1520 battery pack. See below link for detail information about the battery info and how to replace. 952 + 953 +[[**Battery Info & Power Consumption Analyze**>>http://wiki.dragino.com/xwiki/bin/view/Main/How%20to%20calculate%20the%20battery%20life%20of%20Dragino%20sensors%3F/]] . 954 + 955 + 956 += 5. OTA Firmware update = 957 + 958 + 959 +(% class="wikigeneratedid" %) 960 +User can change firmware SW3L-LB to: 961 + 962 +* Change Frequency band/ region. 963 + 964 +* Update with new features. 965 + 966 +* Fix bugs. 967 + 968 +Firmware and changelog can be downloaded from : **[[Firmware download link>>url:https://www.dropbox.com/sh/kwqv57tp6pejias/AAAopYMATh1GM6fZ-VRCLrpDa?dl=0]]** 969 + 970 +Methods to Update Firmware: 971 + 972 +* (Recommanded way) OTA firmware update via wireless: [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/Firmware%20OTA%20Update%20for%20Sensors/>>url:http://wiki.dragino.com/xwiki/bin/view/Main/Firmware%20OTA%20Update%20for%20Sensors/]] 973 + 974 +* Update through UART TTL interface. **[[Instruction>>url:http://wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H1.LoRaSTv4baseHardware]]**. 975 + 976 + 977 += 6. FAQ = 978 + 979 +== 6.1 AT Commands input doesn't work == 980 + 981 + 982 +In the case if user can see the console output but can't type input to the device. Please check if you already include the (% style="color:green" %)**ENTER**(%%) while sending out the command. Some serial tool doesn't send (% style="color:green" %)**ENTER**(%%) while press the send key, user need to add ENTER in their string. 983 + 984 + 985 += 7. Order Info = 986 + 987 + 988 +Part Number: (% style="color:blue" %)**SW3L-LB-XXX-YYY** 989 + 990 +(% style="color:red" %)**XXX**(%%): The default frequency band 991 + 709 709 * (% style="color:red" %)**AS923**(%%): LoRaWAN AS923 band 710 710 711 711 * (% style="color:red" %)**AU915**(%%): LoRaWAN AU915 band ... ... @@ -722,14 +722,43 @@ 722 722 723 723 * (% style="color:red" %)**CN470**(%%): LoRaWAN CN470 band 724 724 1008 +((( 1009 +(% style="color:blue" %)**YYY**(%%): Flow Sensor Model: 1010 +))) 725 725 1012 +((( 1013 + **004:** DW-004 Flow Sensor: diameter: G1/2” / DN15. 450 pulse = 1 L 1014 +))) 726 726 727 -= 9. Packing Info = 1016 +((( 1017 + **006:** DW-006 Flow Sensor: diameter: G3/4” / DN20. 390 pulse = 1 L 1018 +))) 728 728 1020 +((( 1021 + **010:** DW-010 Flow Sensor: diameter: G 1” / DN25. 64 pulse = 1 L 1022 +))) 729 729 1024 +* ((( 1025 +calculate flag=0: for SW3L-004 Flow Sensor: 450 pulse = 1 L 1026 +))) 1027 + 1028 +* ((( 1029 +calculate flag=1: for SW3L-006 Flow Sensor: 390 pulse = 1 L 1030 +))) 1031 + 1032 +* ((( 1033 +calculate flag=2: for SW3L-010 Flow Sensor: 64 pulse = 1 L 1034 + 1035 + 1036 + 1037 +))) 1038 + 1039 += 8. Packing Info = 1040 + 1041 + 730 730 (% style="color:#037691" %)**Package Includes**: 731 731 732 -* DDS45-LB LoRaWANDistance DetectionSensorx 11044 +* SW3L-LB LoRaWAN Flow Sensor 733 733 734 734 (% style="color:#037691" %)**Dimension and weight**: 735 735 ... ... @@ -742,10 +742,9 @@ 742 742 * Weight / pcs : g 743 743 744 744 1057 += 9. Support = 745 745 746 -= 10. Support = 747 747 748 - 749 749 * Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule. 750 750 751 751 * Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[Support@dragino.cc>>mailto:Support@dragino.cc]].
- image-20230613100900-1.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -184.0 KB - Content
- image-20230613102426-2.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -89.3 KB - Content
- image-20230613102459-3.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -89.3 KB - Content