Changes for page DS20L -- LoRaWAN Smart Distance Detector User Manual 01
Last modified by Mengting Qiu on 2023/12/14 11:15
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 3 removed)
Details
- Page properties
-
- Title
-
... ... @@ -1,1 +1,1 @@ 1 -DDS 45-LB -- LoRaWAN Distance Detection Sensor User Manual1 +DDS75-LB -- LoRaWAN Distance Detection Sensor User Manual - Content
-
... ... @@ -1,8 +1,9 @@ 1 1 (% style="text-align:center" %) 2 -[[image:image-2023061 3100900-1.png||height="683" width="683"]]2 +[[image:image-20230612170349-1.png||height="656" width="656"]] 3 3 4 4 5 5 6 + 6 6 **Table of Contents:** 7 7 8 8 {{toc/}} ... ... @@ -17,19 +17,19 @@ 17 17 == 1.1 What is LoRaWAN Distance Detection Sensor == 18 18 19 19 20 -The Dragino DDS 45-LB is a (% style="color:blue" %)** LoRaWAN Distance Detection Sensor**(%%) for Internet of Things solution. It is used to measure the distance between the sensor and a flat object. The distance detection sensor is a module that uses (% style="color:blue" %)** ultrasonic sensing technology**(%%) for (% style="color:blue" %)**distance measurement**(%%), and (% style="color:blue" %)** temperature compensation**(%%) is performed internally to improve the reliability of data. The DDS45-LB can be applied to scenarios such as horizontal distance measurement, liquid level measurement, parking management system, object proximity and presence detection, intelligent trash can management system, robot obstacle avoidance, automatic control, sewer, bottom water level monitoring, etc.21 +The Dragino DDS75-LB is a (% style="color:blue" %)** LoRaWAN Distance Detection Sensor**(%%) for Internet of Things solution. It is used to measure the distance between the sensor and a flat object. The distance detection sensor is a module that uses (% style="color:blue" %)** ultrasonic sensing technology**(%%) for (% style="color:blue" %)**distance measurement**(%%), and (% style="color:blue" %)** temperature compensation**(%%) is performed internally to improve the reliability of data. The DDS75-LB can be applied to scenarios such as horizontal distance measurement, liquid level measurement, parking management system, object proximity and presence detection, intelligent trash can management system, robot obstacle avoidance, automatic control, sewer, bottom water level monitoring, etc. 21 21 22 22 It detects the distance(% style="color:blue" %)** between the measured object and the sensor**(%%), and uploads the value via wireless to LoRaWAN IoT Server. 23 23 24 -The LoRa wireless technology used in DDS45-LB allows device to send data and reach extremely long ranges at low data-rates. It provides ultra-long range spread spectrum communication and high interference immunity whilst minimizing current consumption.25 +The LoRa wireless technology used in SW3L-LB allows device to send data and reach extremely long ranges at low data-rates. It provides ultra-long range spread spectrum communication and high interference immunity whilst minimizing current consumption. 25 25 26 - DDS45-LB (% style="color:blue" %)**supports BLE configure**(%%) and (% style="color:blue" %)**wireless OTA update**(%%) which make user easy to use.27 +SW3L-LB (% style="color:blue" %)**supports BLE configure**(%%) and (% style="color:blue" %)**wireless OTA update**(%%) which make user easy to use. 27 27 28 - DDS45-LB is powered by (% style="color:blue" %)**8500mAh Li-SOCI2 battery**(%%), it is designed for long term use up to 5 years.29 +SW3L-LB is powered by (% style="color:blue" %)**8500mAh Li-SOCI2 battery**(%%), it is designed for long term use up to 5 years. 29 29 30 -Each DDS45-LB is pre-load with a set of unique keys for LoRaWAN registrations, register these keys to local LoRaWAN server and it will auto connect after power on.31 +Each SW3L-LB is pre-load with a set of unique keys for LoRaWAN registrations, register these keys to local LoRaWAN server and it will auto connect after power on. 31 31 32 -[[image:image-2023061 3102459-3.png||height="476" width="855"]]33 +[[image:image-20230612170943-2.png||height="525" width="912"]] 33 33 34 34 35 35 == 1.2 Features == ... ... @@ -39,9 +39,8 @@ 39 39 * Bands: CN470/EU433/KR920/US915/EU868/AS923/AU915/IN865 40 40 * Ultra-low power consumption 41 41 * Distance Detection by Ultrasonic technology 42 -* Flat object range 30mm -4500mm43 +* Flat object range 280mm - 7500mm 43 43 * Accuracy: ±(1cm+S*0.3%) (S: Distance) 44 -* Measure Angle: 60° 45 45 * Cable Length : 25cm 46 46 * Support Bluetooth v5.1 and LoRaWAN remote configure 47 47 * Support wireless OTA update firmware ... ... @@ -53,6 +53,33 @@ 53 53 == 1.3 Specification == 54 54 55 55 56 +(% style="color:#037691" %)**Rated environmental conditions:** 57 + 58 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:500px" %) 59 +|(% style="background-color:#d9e2f3; color:#0070c0; width:163px" %)**Item**|(% style="background-color:#d9e2f3; color:#0070c0; width:90px" %)((( 60 +**Minimum value** 61 +)))|(% style="background-color:#d9e2f3; color:#0070c0; width:70px" %)((( 62 +**Typical value** 63 +)))|(% style="background-color:#d9e2f3; color:#0070c0; width:87px" %)((( 64 +**Maximum value** 65 +)))|(% style="background-color:#d9e2f3; color:#0070c0; width:40px" %)**Unit**|(% style="background-color:#d9e2f3; color:#0070c0; width:50px" %)**Remarks** 66 +|(% style="width:174px" %)Storage temperature|(% style="width:86px" %)-25|(% style="width:66px" %)25|(% style="width:90px" %)80|(% style="width:48px" %)℃|(% style="width:203px" %) 67 +|(% style="width:174px" %)Storage humidity|(% style="width:86px" %) |(% style="width:66px" %)65%|(% style="width:90px" %)90%|(% style="width:48px" %)RH|(% style="width:203px" %)(1) 68 +|(% style="width:174px" %)Operating temperature|(% style="width:86px" %)-15|(% style="width:66px" %)25|(% style="width:90px" %)60|(% style="width:48px" %)℃|(% style="width:203px" %) 69 +|(% style="width:174px" %)Working humidity|(% style="width:86px" %)((( 70 + 71 + 72 + 73 +)))|(% style="width:66px" %)65%|(% style="width:90px" %)80%|(% style="width:48px" %)RH|(% style="width:203px" %)(1) 74 + 75 +((( 76 +**Remarks: (1) a. When the ambient temperature is 0-39 ℃, the maximum humidity is 90% (non-condensing); ** 77 + 78 +**~ b. When the ambient temperature is 40-50 ℃, the highest humidity is the highest humidity in the natural world at the current temperature (no condensation)** 79 + 80 + 81 +))) 82 + 56 56 (% style="color:#037691" %)**Common DC Characteristics:** 57 57 58 58 * Supply Voltage: built in 8500mAh Li-SOCI2 battery , 2.5v ~~ 3.6v ... ... @@ -78,48 +78,21 @@ 78 78 * Sleep Mode: 5uA @ 3.3v 79 79 * LoRa Transmit Mode: 125mA @ 20dBm, 82mA @ 14dBm 80 80 81 -== 1.4 Rated environmental conditions == 82 82 109 +== 1.4 Effective measurement range Reference beam pattern == 83 83 84 -(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:500px" %) 85 -|(% style="background-color:#d9e2f3; color:#0070c0; width:163px" %)**Item**|(% style="background-color:#d9e2f3; color:#0070c0; width:90px" %)((( 86 -**Minimum value** 87 -)))|(% style="background-color:#d9e2f3; color:#0070c0; width:70px" %)((( 88 -**Typical value** 89 -)))|(% style="background-color:#d9e2f3; color:#0070c0; width:87px" %)((( 90 -**Maximum value** 91 -)))|(% style="background-color:#d9e2f3; color:#0070c0; width:40px" %)**Unit**|(% style="background-color:#d9e2f3; color:#0070c0; width:50px" %)**Remarks** 92 -|(% style="width:174px" %)Storage temperature|(% style="width:86px" %)-25|(% style="width:66px" %)25|(% style="width:90px" %)80|(% style="width:48px" %)℃|(% style="width:203px" %) 93 -|(% style="width:174px" %)Storage humidity|(% style="width:86px" %) |(% style="width:66px" %)65%|(% style="width:90px" %)90%|(% style="width:48px" %)RH|(% style="width:203px" %)(1) 94 -|(% style="width:174px" %)Operating temperature|(% style="width:86px" %)-15|(% style="width:66px" %)25|(% style="width:90px" %)60|(% style="width:48px" %)℃|(% style="width:203px" %) 95 -|(% style="width:174px" %)Working humidity|(% style="width:86px" %)((( 96 - 97 97 98 - 99 -)))|(% style="width:66px" %)65%|(% style="width:90px" %)80%|(% style="width:48px" %)RH|(% style="width:203px" %)(1) 112 +**~1. The tested object is a white cylindrical tube made of PVC, with a height of 100cm and a diameter of 7.5cm.** 100 100 101 -((( 102 -(% style="color:red" %)**Remarks: (1) a. When the ambient temperature is 0-39 ℃, the maximum humidity is 90% (non-condensing); ** 103 - 104 -(% style="color:red" %)** b. When the ambient temperature is 40-50 ℃, the highest humidity is the highest humidity in the natural world at the current temperature (no condensation)** 105 - 106 - 107 -))) 108 - 109 -== 1.5 Effective measurement range Reference beam pattern == 110 - 111 - 112 -(% style="color:blue" %)**1. The tested object is a white cylindrical tube made of PVC, with a height of 100cm and a diameter of 7.5cm.** 113 - 114 114 [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDDS75%20-%20LoRaWAN%20Distance%20Detection%20Sensor%20User%20Manual/WebHome/1654852253176-749.png?rev=1.1||alt="1654852253176-749.png"]] 115 115 116 116 117 - (% style="color:blue" %)**2. The object to be tested is a "corrugated cardboard box" perpendicular to the central axis of 0 °, and the length * width is 60cm * 50cm.**117 +**2. The object to be tested is a "corrugated cardboard box" perpendicular to the central axis of 0 °, and the length * width is 60cm * 50cm.** 118 118 119 119 [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDDS75%20-%20LoRaWAN%20Distance%20Detection%20Sensor%20User%20Manual/WebHome/1654852175653-550.png?rev=1.1||alt="1654852175653-550.png"]] 120 120 121 121 122 -== 1. 6Applications ==122 +== 1.5 Applications == 123 123 124 124 125 125 * Horizontal distance measurement ... ... @@ -132,7 +132,7 @@ 132 132 * Sewer 133 133 * Bottom water level monitoring 134 134 135 -== 1. 7Sleep mode and working mode ==135 +== 1.6 Sleep mode and working mode == 136 136 137 137 138 138 (% style="color:blue" %)**Deep Sleep Mode: **(%%)Sensor doesn't have any LoRaWAN activate. This mode is used for storage and shipping to save battery life. ... ... @@ -140,7 +140,7 @@ 140 140 (% style="color:blue" %)**Working Mode:** (%%)In this mode, Sensor will work as LoRaWAN Sensor to Join LoRaWAN network and send out sensor data to server. Between each sampling/tx/rx periodically, sensor will be in IDLE mode), in IDLE mode, sensor has the same power consumption as Deep Sleep mode. 141 141 142 142 143 -== 1. 8Button & LEDs ==143 +== 1.7 Button & LEDs == 144 144 145 145 146 146 [[image:Main.User Manual for LoRaWAN End Nodes.D20-LBD22-LBD23-LB_LoRaWAN_Temperature_Sensor_User_Manual.WebHome@1675071855856-879.png]] ... ... @@ -159,10 +159,10 @@ 159 159 ))) 160 160 |(% style="width:167px" %)Fast press ACT 5 times.|(% style="width:117px" %)Deactivate Device|(% style="width:225px" %)(% style="color:red" %)**Red led**(%%) will solid on for 5 seconds. Means device is in Deep Sleep Mode. 161 161 162 -== 1. 9BLE connection ==162 +== 1.8 BLE connection == 163 163 164 164 165 -DDS 45-LB support BLE remote configure.165 +DDS75-LB support BLE remote configure. 166 166 167 167 168 168 BLE can be used to configure the parameter of sensor or see the console output from sensor. BLE will be only activate on below case: ... ... @@ -174,14 +174,16 @@ 174 174 If there is no activity connection on BLE in 60 seconds, sensor will shut down BLE module to enter low power mode. 175 175 176 176 177 -== 1. 10Pin Definitions ==177 +== 1.9 Pin Definitions == 178 178 179 179 [[image:image-20230523174230-1.png]] 180 180 181 181 182 -== 1.11Mechanical==182 +== == 183 183 184 +== 2.10 Mechanical == 184 184 186 + 185 185 [[image:Main.User Manual for LoRaWAN End Nodes.D20-LBD22-LBD23-LB_LoRaWAN_Temperature_Sensor_User_Manual.WebHome@1675143884058-338.png]] 186 186 187 187 ... ... @@ -191,19 +191,12 @@ 191 191 [[image:Main.User Manual for LoRaWAN End Nodes.D20-LBD22-LBD23-LB_LoRaWAN_Temperature_Sensor_User_Manual.WebHome@1675143909447-639.png]] 192 192 193 193 194 - (% style="color:blue"%)**ProbeMechanical:**196 += 2. Configure DDS75-LB to connect to LoRaWAN network = 195 195 196 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDDS45%20-%20LoRaWAN%20Distance%20Detection%20Sensor%20User%20Manual/WebHome/1654915562090-396.png?rev=1.1||alt="1654915562090-396.png"]] 197 - 198 - 199 - 200 - 201 -= 2. Configure DDS45-LB to connect to LoRaWAN network = 202 - 203 203 == 2.1 How it works == 204 204 205 205 206 -The DDS 45-LB is configured as (% style="color:#037691" %)**LoRaWAN OTAA Class A**(%%) mode by default. It has OTAA keys to join LoRaWAN network. To connect a local LoRaWAN network, you need to input the OTAA keys in the LoRaWAN IoT server and press the button to activate the DDS45-LB. It will automatically join the network via OTAA and start to send the sensor value. The default uplink interval is 20 minutes.201 +The DDS75-LB is configured as (% style="color:#037691" %)**LoRaWAN OTAA Class A**(%%) mode by default. It has OTAA keys to join LoRaWAN network. To connect a local LoRaWAN network, you need to input the OTAA keys in the LoRaWAN IoT server and press the button to activate the DDS75-LB. It will automatically join the network via OTAA and start to send the sensor value. The default uplink interval is 20 minutes. 207 207 208 208 (% style="display:none" %) (%%) 209 209 ... ... @@ -214,12 +214,12 @@ 214 214 215 215 The LPS8v2 is already set to connected to [[TTN network >>url:https://console.cloud.thethings.network/]], so what we need to now is configure the TTN server. 216 216 217 -[[image:image-2023061 3102426-2.png||height="476" width="855"]](% style="display:none" %)212 +[[image:image-20230612171032-3.png||height="492" width="855"]](% style="display:none" %) 218 218 219 219 220 -(% style="color:blue" %)**Step 1:**(%%) Create a device in TTN with the OTAA keys from DDS 45-LB.215 +(% style="color:blue" %)**Step 1:**(%%) Create a device in TTN with the OTAA keys from DDS75-LB. 221 221 222 -Each DDS 45-LB is shipped with a sticker with the default device EUI as below:217 +Each DDS75-LB is shipped with a sticker with the default device EUI as below: 223 223 224 224 [[image:image-20230426084152-1.png||alt="图片-20230426084152-1.png" height="233" width="502"]] 225 225 ... ... @@ -248,10 +248,10 @@ 248 248 [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LSN50v2-S31-S31B%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20User%20Manual/WebHome/image-20220611161308-6.png?width=744&height=485&rev=1.1||alt="图片-20220611161308-6.png"]] 249 249 250 250 251 -(% style="color:blue" %)**Step 2:**(%%) Activate on DDS45-LB246 +(% style="color:blue" %)**Step 2:**(%%) Activate on SW3L-LB 252 252 253 253 254 -Press the button for 5 seconds to activate the DDS45-LB.249 +Press the button for 5 seconds to activate the SW3L-LB. 255 255 256 256 (% style="color:green" %)**Green led**(%%) will fast blink 5 times, device will enter (% style="color:blue" %)**OTA mode**(%%) for 3 seconds. And then start to JOIN LoRaWAN network. (% style="color:green" %)**Green led**(%%) will solidly turn on for 5 seconds after joined in network. 257 257 ... ... @@ -258,169 +258,355 @@ 258 258 After join success, it will start to upload messages to TTN and you can see the messages in the panel. 259 259 260 260 261 -== 2.3 256 +== 2.3 Uplink Payload == 262 262 258 +=== 2.3.1 Device Status, FPORT~=5 === 263 263 264 -((( 265 -DDS45-LB will uplink payload via LoRaWAN with below payload format: 266 -))) 267 267 268 -((( 269 -Uplink payload includes in total 8 bytes. 270 -))) 261 +Include device configure status. Once SW3L-LB Joined the network, it will uplink this message to the server. After that, SW3L-LB will uplink Device Status every 12 hours. 271 271 272 -(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:510px" %) 273 -|=(% style="width: 62.5px;background-color:#D9E2F3;color:#0070C0" %)((( 274 -**Size(bytes)** 275 -)))|=(% style="width: 62.5px;background-color:#D9E2F3;color:#0070C0" %)**2**|=(% style="background-color:#D9E2F3;color:#0070C0" %)**2**|=(% style="background-color:#D9E2F3;color:#0070C0" %)1|=(% style="background-color:#D9E2F3;color:#0070C0" %)2|=(% style="background-color:#D9E2F3;color:#0070C0" %)**1** 276 -|(% style="width:62.5px" %)**Value**|(% style="width:62.5px" %)[[BAT>>||anchor="H2.3.1A0BatteryInfo"]]|((( 277 -[[Distance>>||anchor="H2.3.2A0Distance"]] 278 -(unit: mm) 279 -)))|[[Digital Interrupt (Optional)>>||anchor="H2.3.3A0InterruptPin"]]|((( 280 -[[Temperature (Optional )>>||anchor="H2.3.4A0DS18B20Temperaturesensor"]] 281 -)))|[[Sensor Flag>>||anchor="H2.3.5A0SensorFlag"]] 263 +Users can use the downlink command(**0x26 01**) to ask SW3L-LB to send device configure detail, include device configure status. SW3L-LB will uplink a payload via FPort=5 to server. 282 282 283 - [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDDS75%20-%20LoRaWAN%20Distance%20Detection%20Sensor%20User%20Manual/WebHome/1654850511545-399.png?rev=1.1||alt="1654850511545-399.png"]]265 +The Payload format is as below. 284 284 285 285 286 -=== 2.3.1 Battery Info === 268 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %) 269 +|(% colspan="6" style="background-color:#d9e2f3; color:#0070c0" %)**Device Status (FPORT=5)** 270 +|(% style="width:103px" %)**Size (bytes)**|(% style="width:72px" %)**1**|**2**|(% style="width:91px" %)**1**|(% style="width:86px" %)**1**|(% style="width:44px" %)**2** 271 +|(% style="width:103px" %)**Value**|(% style="width:72px" %)Sensor Model|Firmware Version|(% style="width:91px" %)Frequency Band|(% style="width:86px" %)Sub-band|(% style="width:44px" %)BAT 287 287 273 +Example parse in TTNv3 288 288 289 - Check the battery voltageDDS45-LB.275 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/SW3L%20LoRaWAN%20Outdoor%20Flow%20Sensor/WebHome/1652925144491-755.png?width=732&height=139&rev=1.1||alt="1652925144491-755.png"]] 290 290 277 + 278 +(% style="color:#037691" %)**Sensor Model**(%%): For SW3L-LB, this value is 0x11 279 + 280 +(% style="color:#037691" %)**Firmware Version**(%%): 0x0100, Means: v1.0.0 version 281 + 282 +(% style="color:#037691" %)**Frequency Band**: 283 + 284 +*0x01: EU868 285 + 286 +*0x02: US915 287 + 288 +*0x03: IN865 289 + 290 +*0x04: AU915 291 + 292 +*0x05: KZ865 293 + 294 +*0x06: RU864 295 + 296 +*0x07: AS923 297 + 298 +*0x08: AS923-1 299 + 300 +*0x09: AS923-2 301 + 302 +*0x0a: AS923-3 303 + 304 +*0x0b: CN470 305 + 306 +*0x0c: EU433 307 + 308 +*0x0d: KR920 309 + 310 +*0x0e: MA869 311 + 312 + 313 +(% style="color:#037691" %)**Sub-Band**: 314 + 315 +AU915 and US915:value 0x00 ~~ 0x08 316 + 317 +CN470: value 0x0B ~~ 0x0C 318 + 319 +Other Bands: Always 0x00 320 + 321 + 322 +(% style="color:#037691" %)**Battery Info**: 323 + 324 +Check the battery voltage. 325 + 291 291 Ex1: 0x0B45 = 2885mV 292 292 293 293 Ex2: 0x0B49 = 2889mV 294 294 295 295 296 -=== 2.3.2 Distance===331 +=== 2.3.2 Sensor Configuration, FPORT~=4 === 297 297 298 298 334 +SW3L-LB will only send this command after getting the downlink command (0x26 02) from the server. 335 + 336 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:510px" %) 337 +|(% style="background-color:#d9e2f3; color:#0070c0; width:70px" %) **Size(bytes)**|(% style="background-color:#d9e2f3; color:#0070c0; width:105px" %)**3**|(% style="background-color:#d9e2f3; color:#0070c0; width:60px" %)**1**|(% style="background-color:#d9e2f3; color:#0070c0; width:96px" %)**1**|(% style="background-color:#d9e2f3; color:#0070c0; width:105px" %)**2**|(% style="background-color:#d9e2f3; color:#0070c0; width:74px" %)**1** 338 +|**Value**|(% style="width:104px" %)TDC(unit:sec)|(% style="width:43px" %)N/A|(% style="width:91px" %)Stop Timer|(% style="width:100px" %)Alarm Timer|(% style="width:69px" %)Reserve 339 + 340 +* (% style="color:#037691" %)**TDC: (default: 0x0004B0)** 341 + 342 +Uplink interval for the total pulse count, default value is 0x0004B0 which is 1200 seconds = 20 minutes. 343 + 344 + 345 +* (% style="color:#037691" %)**STOP Duration & Alarm Timer** 346 + 347 +Shows the configure value of [[Alarm for continuously water flow>>||anchor="H3.3.4Alarmforcontinuouslywaterflow"]] 348 + 349 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/SW3L%20LoRaWAN%20Outdoor%20Flow%20Sensor/WebHome/image-20220519095747-2.png?width=723&height=113&rev=1.1||alt="image-20220519095747-2.png"]] 350 + 351 + 352 +=== 2.3.3 Water Flow Value, Uplink FPORT~=2 === 353 + 354 + 299 299 ((( 300 - Getthe distance.Flat objectrange30mm-4500mm.356 +SW3L-LB will send this uplink **after** Device Status once join the LoRaWAN network successfully. And SW3L-LB will: 301 301 ))) 302 302 303 303 ((( 304 -For example, if the data you get from the register is **0x0B 0x05**, the distance between the sensor and the measured object is(% style="color:#4472c4" %)** ** 360 +periodically send this uplink every 20 minutes, this interval [[can be changed>>||anchor="H3.3.1SetTransmitIntervalTime"]]. 361 +))) 305 305 306 -(% style="color:blue" %)**0B05(H) = 2821 (D) = 2821 mm.** 363 +((( 364 +Uplink Payload totals 11 bytes. 307 307 ))) 308 308 367 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:510px" %) 368 +|=(% colspan="6" style="width: 510px;background-color:#D9E2F3;color:#0070C0" %)**Water Flow Value, FPORT=2** 369 +|(% style="width:60px" %)**Size(bytes)**|(% style="width:130px" %)**1**|(% style="width:130px" %)**4**|(% style="width:30px" %)**1**|(% style="width:50px" %)**1**|(% style="width:80px" %)**4** 370 +|(% style="width:110px" %)**Value**|(% style="width:81px" %)Calculate Flag & [[Alarm>>||anchor="H3.3.4Alarmforcontinuouslywaterflow"]]|(% style="width:95px" %)((( 371 +Total pulse Or Last Pulse 372 +)))|(% style="width:55px" %)MOD|(% style="width:115px" %)Reserve(0x01)|(% style="width:129px" %)[[Unix TimeStamp>>||anchor="H2.5.2UnixTimeStamp"]] 309 309 310 -* If the sensor value is 0x0000, it means system doesn't detect ultrasonic sensor. 311 -* If the sensor value lower than 0x001E (30mm), the sensor value will be 0x00. 374 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:470px" %) 375 +|=(% colspan="4" style="width: 470px;background-color:#D9E2F3;color:#0070C0" %)**Status & Alarm field** 376 +|(% style="width:60px" %)**Size(bit)**|(% style="width:80px" %)**6**|(% style="width:310px" %)**1**|(% style="width:20px" %)**1** 377 +|(% style="width:88px" %)**Value**|(% style="width:117px" %)Calculate Flag|(% style="width:221px" %)Alarm: 0: No Alarm; 1: Alarm|(% style="width:64px" %)N/A 312 312 379 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/SW3L%20LoRaWAN%20Outdoor%20Flow%20Sensor/WebHome/image-20220519095946-3.png?width=736&height=284&rev=1.1||alt="image-20220519095946-3.png"]] 313 313 314 314 382 +* ((( 383 +(% style="color:#037691" %)**Calculate Flag** 384 +))) 315 315 316 -=== 2.3.3 Interrupt Pin === 386 +((( 387 +The calculate flag is a user defined field, IoT server can use this flag to handle different meters with different pulse factors. For example, if there are 100 Flow Sensors, meters 1 ~~50 are 1 liter/pulse and meters 51 ~~ 100 has 1.5 liter/pulse. 388 +))) 317 317 390 +((( 391 +**Example: in the default payload:** 392 +))) 318 318 319 -This data field shows if this packet is generated by interrupt or not. [[Click here>>||anchor="H3.3.2SetInterruptMode"]] for the hardware and software set up. 394 +* ((( 395 +calculate flag=0: for SW3L-004 Flow Sensor: 450 pulse = 1 L 396 +))) 397 +* ((( 398 +calculate flag=1: for SW3L-006 Flow Sensor: 390 pulse = 1 L 399 +))) 400 +* ((( 401 +calculate flag=2: for SW3L-010 Flow Sensor: 64 pulse = 1 L 402 +))) 320 320 321 -**Example:** 404 +((( 405 +Default value: 0. 406 +))) 322 322 323 -0x00: Normal uplink packet. 408 +((( 409 +Range (6 bits): (b)000000 ~~ (b) 111111 324 324 325 - 0x01:InterruptUplinkPacket.411 +If user use with a meter for example is 0.02L/pulse. To proper decode the correct value in server, 326 326 413 +1) User can set the Calculate Flag of this sensor to 3. 327 327 328 -=== 2.3.4 DS18B20 Temperature sensor === 415 +2) In server side, when a sensor data arrive, the decoder will check the value of Calculate Flag, It the value is 3, the total volume = 0.02 x Pulse Count. 416 +))) 329 329 418 +((( 419 +(% style="color:red" %)**NOTE: User need to set Calculate Flag to proper value before use Flow Sensor. Downlink or AT Command see: **(%%)Refer: [[Set Calculate Flag>>||anchor="H3.3.6Setthecalculateflag"]] 420 +))) 330 330 331 -This is optional, user can connect external DS18B20 sensor to the +3.3v, 1-wire and GND pin . and this field will report temperature. 422 +* ((( 423 +(% style="color:#037691" %)**Alarm** 424 +))) 332 332 333 -**Example**: 426 +((( 427 +See [[Alarm for continuously water flow>>||anchor="H3.3.4Alarmforcontinuouslywaterflow"]] 428 +))) 334 334 335 - Ifpayload:0105H: (0105 & FC00==0),temp =0105H /10= 26.1degree430 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/SW3L%20LoRaWAN%20Outdoor%20Flow%20Sensor/WebHome/image-20220519095946-4.png?width=724&height=65&rev=1.1||alt="image-20220519095946-4.png"]] 336 336 337 -If payload is: FF3FH : (FF3F & FC00 == 1) , temp = (FF3FH - 65536)/10 = -19.3 degrees. 338 338 433 +* ((( 434 +(% style="color:#037691" %)**Total pulse** 435 +))) 339 339 340 -=== 2.3.5 Sensor Flag === 437 +((( 438 +Total pulse/counting since factory 439 +))) 341 341 441 +((( 442 +Range (4 Bytes) : 0x00000000~~ 0xFFFFFFFF . 443 +))) 342 342 445 +* ((( 446 +(% style="color:#037691" %)**Last Pulse** 447 +))) 448 + 343 343 ((( 344 - 0x01:DetectUltrasonicSensor450 +Total pulse since last FPORT=2 uplink. (Default 20 minutes) 345 345 ))) 346 346 347 347 ((( 348 -0x00 :NoUltrasonic Sensor454 +Range (4 Bytes) : 0x00000000~~ 0xFFFFFFFF . 349 349 ))) 350 350 457 +* ((( 458 +(% style="color:#037691" %)**MOD: Default =0** 459 +))) 351 351 352 -=== 2.3.6 Decode payload in The Things Network === 461 +((( 462 +MOD=0 ~-~-> Uplink Total Pulse since factory 463 +))) 353 353 465 +((( 466 +MOD=1 ~-~-> Uplink total pulse since last FPORT=2 uplink. 467 +))) 354 354 355 -While using TTN network, you can add the payload format to decode the payload. 469 +* ((( 470 +(% style="color:#037691" %)**Water Flow Value** 471 +))) 356 356 357 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDDS75%20-%20LoRaWAN%20Distance%20Detection%20Sensor%20User%20Manual/WebHome/1654850829385-439.png?rev=1.1||alt="1654850829385-439.png"]] 473 +((( 474 +**Total Water Flow Volume = (Calculate Flag) x (Total Pulse)=9597/450=21.3L** 475 +))) 358 358 359 - Theyloaddecoder functionforTTN V3ishere:477 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/SW3L%20LoRaWAN%20Outdoor%20Flow%20Sensor/WebHome/image-20220519095946-5.png?width=727&height=50&rev=1.1||alt="image-20220519095946-5.png"]] 360 360 479 + 361 361 ((( 362 - DDS45-LBTTNV3 PayloadDecoder: [[ttps:~~/~~/github.com/dragino/dragino-end-node-decoder>>https://github.com/dragino/dragino-end-node-decoder]]481 +**Total Water Flow for TDC timer = (Calculate Flag) x (Last Pulse)=79/450=0.2L** 363 363 ))) 364 364 484 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/SW3L%20LoRaWAN%20Outdoor%20Flow%20Sensor/WebHome/image-20220519095946-6.png?width=733&height=43&rev=1.1||alt="image-20220519095946-6.png"]] ** ** 365 365 366 -== 2.4 Uplink Interval == 367 367 487 +=== 2.3.4 Historical Water Flow Status, FPORT~=3 === 368 368 369 -The DDS45-LB by default uplink the sensor data every 20 minutes. User can change this interval by AT Command or LoRaWAN Downlink Command. See this link: [[Change Uplink Interval>>||anchor="H3.3.1SetTransmitIntervalTime"]] 370 370 490 +((( 491 +SW3L-LB stores sensor values and users can retrieve these history values via the [[downlink command>>||anchor="H2.5DatalogFeature"]]. 492 +))) 371 371 372 -== 2.5 Show Data in DataCake IoT Server == 494 +((( 495 +The historical payload includes one or multiplies entries and every entry has the same payload as Real-Time water flow status. 496 +))) 373 373 498 +* ((( 499 +Each data entry is 11 bytes and has the same structure as [[real time water flow status>>||anchor="H2.3.3A0WaterFlowValue2CUplinkFPORT3D2"]], to save airtime and battery, SW3L will send max bytes according to the current DR and Frequency bands. 500 +))) 374 374 375 375 ((( 376 - [[DATACAKE>>url:https://datacake.co/]] providesahuman friendlyinterfaceto show thesensordata, once we havedata in TTN,wecanuse [[DATACAKE>>url:https://datacake.co/]] to connect to TTNandseethedatain DATACAKE. Below arehesteps:503 +For example, in the US915 band, the max payload for different DR is: 377 377 ))) 378 378 506 +((( 507 +(% style="color:blue" %)**a) DR0:**(%%) max is 11 bytes so one entry of data 508 +))) 379 379 380 380 ((( 381 -(% style="color:blue" %)** Step1**(%%)**:Besurethatyourdevice isprogrammedandproperly connectedto thenetwork atthistime.**511 +(% style="color:blue" %)**b) DR1:**(%%) max is 53 bytes so devices will upload 4 entries of data (total 44 bytes) 382 382 ))) 383 383 384 384 ((( 385 -(% style="color:blue" %)** Step2**(%%)**:To configurethe Applicationto forwarddata to DATACAKEyou will need todintegration. To add theDATACAKEintegration, performthe followingsteps:**515 +(% style="color:blue" %)**c) DR2:**(%%) total payload includes 11 entries of data 386 386 ))) 387 387 518 +((( 519 +(% style="color:blue" %)**d) DR3:**(%%) total payload includes 22 entries of data. 520 +))) 388 388 389 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDDS75%20-%20LoRaWAN%20Distance%20Detection%20Sensor%20User%20Manual/WebHome/1654592790040-760.png?rev=1.1||alt="1654592790040-760.png"]] 522 +((( 523 +If SW3L-LB doesn't have any data in the polling time. It will uplink 11 bytes of 0 524 +))) 390 390 526 +((( 527 +(% style="color:#037691" %)**Downlink:** 528 +))) 391 391 392 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDDS75%20-%20LoRaWAN%20Distance%20Detection%20Sensor%20User%20Manual/WebHome/1654592800389-571.png?rev=1.1||alt="1654592800389-571.png"]] 530 +((( 531 +0x31 62 46 B1 F0 62 46 B3 94 07 532 +))) 393 393 534 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/SW3L%20LoRaWAN%20Outdoor%20Flow%20Sensor/WebHome/1652926690850-712.png?width=726&height=115&rev=1.1||alt="1652926690850-712.png"]] 394 394 395 -(% style="color:blue" %)**Step 3**(%%)**: Create an account or log in Datacake.** 396 396 397 -(% style="color:blue" %)**Step 4**(%%)**: Search the DDS45-LB and add DevEUI.** 537 +((( 538 +(% style="color:#037691" %)**Uplink:** 539 +))) 398 398 399 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDDS75%20-%20LoRaWAN%20Distance%20Detection%20Sensor%20User%20Manual/WebHome/1654851029373-510.png?rev=1.1||alt="1654851029373-510.png"]] 541 +((( 542 +00 00 01 00 00 00 00 62 46 B2 26 00 00 01 00 00 00 00 62 46 B2 5D 00 00 01 00 00 00 00 62 46 B2 99 00 00 01 00 00 00 00 62 46 B2 D5 00 00 01 00 00 01 15 62 46 B3 11 00 00 01 00 00 01 1F 62 46 B3 7E 543 +))) 400 400 545 +((( 546 +(% style="color:#037691" %)**Parsed Value:** 547 +))) 401 401 402 -After added, the sensor data arrive TTN V3, it will also arrive and show in Datacake. 549 +((( 550 +[Alarm, Calculate Flag, MOD, Total pulse or Last Pulse,** **Water Flow Value, TIME] 551 +))) 403 403 404 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDDS75%20-%20LoRaWAN%20Distance%20Detection%20Sensor%20User%20Manual/WebHome/image-20220610165129-11.png?width=1088&height=595&rev=1.1||alt="image-20220610165129-11.png"]] 405 405 554 +((( 555 +[FALSE,0,0,0,0.0,2022-04-01 08:04:54], 556 +))) 406 406 558 +((( 559 +[FALSE,0,0,0,0.0,2022-04-01 08:05:49], 560 +))) 407 407 408 -== 2.6 Datalog Feature == 562 +((( 563 +[FALSE,0,0,0,0.0,2022-04-01 08:06:49], 564 +))) 409 409 566 +((( 567 +[FALSE,0,0,0,0.0,2022-04-01 08:07:49], 568 +))) 410 410 411 -Datalog Feature is to ensure IoT Server can get all sampling data from Sensor even if the LoRaWAN network is down. For each sampling, DDS45-LB will store the reading for future retrieving purposes. 570 +((( 571 +[FALSE,0,0,277,0.6,2022-04-01 08:08:49], 572 +))) 412 412 574 +((( 575 +[FALSE,0,0,287,0.6,2022-04-01 08:10:38], 576 +))) 413 413 414 - === 2.6.1 Ways togettalog via578 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/SW3L%20LoRaWAN%20Outdoor%20Flow%20Sensor/WebHome/1652926777796-267.png?width=724&height=279&rev=1.1||alt="1652926777796-267.png"]] 415 415 416 416 417 - Set PNACKMD=1,DDS45-LBwill wait for ACK for everyuplink, when there is noLoRaWANnetwork,DDS45-LB will mark these records with non-ack messages and storethe sensor data, andit will sendall messages (10s interval) after the network recovery.581 +== 2.4 Payload Decoder file == 418 418 583 + 584 +In TTN, use can add a custom payload so it shows friendly reading 585 + 586 +In the page (% style="color:#037691" %)**Applications ~-~-> Payload Formats ~-~-> Custom ~-~-> decoder**(%%) to add the decoder from: [[https:~~/~~/github.com/dragino/dragino-end-node-decoder>>https://github.com/dragino/dragino-end-node-decoder]] 587 + 588 + 589 +== 2.5 Datalog Feature == 590 + 591 + 592 +Datalog Feature is to ensure IoT Server can get all sampling data from Sensor even if the LoRaWAN network is down. For each sampling, SW3L-LB will store the reading for future retrieving purposes. 593 + 594 + 595 +=== 2.5.1 Ways to get datalog via LoRaWAN === 596 + 597 + 598 +Set PNACKMD=1, SW3L-LB will wait for ACK for every uplink, when there is no LoRaWAN network,SW3L-LB will mark these records with non-ack messages and store the sensor data, and it will send all messages (10s interval) after the network recovery. 599 + 419 419 * ((( 420 -a) DDS45-LB will do an ACK check for data records sending to make sure every data arrive server.601 +a) SW3L-LB will do an ACK check for data records sending to make sure every data arrive server. 421 421 ))) 422 422 * ((( 423 -b) DDS45-LB will send data in **CONFIRMED Mode** when PNACKMD=1, butDDS45-LB won't re-transmit the packet if it doesn't get ACK, it will just mark it as a NONE-ACK message. In a future uplink ifDDS45-LB gets a ACK,DDS45-LB will consider there is a network connection and resend all NONE-ACK messages.604 +b) SW3L-LB will send data in **CONFIRMED Mode** when PNACKMD=1, but SW3L-LB won't re-transmit the packet if it doesn't get ACK, it will just mark it as a NONE-ACK message. In a future uplink if SW3L-LB gets a ACK, SW3L-LB will consider there is a network connection and resend all NONE-ACK messages. 424 424 ))) 425 425 426 426 Below is the typical case for the auto-update datalog feature (Set PNACKMD=1) ... ... @@ -428,10 +428,10 @@ 428 428 [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/WebHome/image-20220703111700-2.png?width=1119&height=381&rev=1.1||alt="图片-20220703111700-2.png" height="381" width="1119"]] 429 429 430 430 431 -=== 2. 6.2 Unix TimeStamp ===612 +=== 2.5.2 Unix TimeStamp === 432 432 433 433 434 - DDS45-LB uses Unix TimeStamp format based on615 +SW3L-LB uses Unix TimeStamp format based on 435 435 436 436 [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/WebHome/image-20220523001219-11.png?width=627&height=97&rev=1.1||alt="图片-20220523001219-11.png" height="97" width="627"]] 437 437 ... ... @@ -445,17 +445,17 @@ 445 445 So, we can use AT+TIMESTAMP=1611889405 or downlink 3060137afd00 to set the current time 2021 – Jan ~-~- 29 Friday 03:03:25 446 446 447 447 448 -=== 2. 6.3 Set Device Time ===629 +=== 2.5.3 Set Device Time === 449 449 450 450 451 451 User need to set (% style="color:blue" %)**SYNCMOD=1**(%%) to enable sync time via MAC command. 452 452 453 -Once DDS45-LB Joined LoRaWAN network, it will send the MAC command (DeviceTimeReq) and the server will reply with (DeviceTimeAns) to send the current time toDDS45-LB. IfDDS45-LB fails to get the time from the server,DDS45-LB will use the internal time and wait for next time request (AT+SYNCTDC to set the time request period, default is 10 days).634 +Once SW3L-LB Joined LoRaWAN network, it will send the MAC command (DeviceTimeReq) and the server will reply with (DeviceTimeAns) to send the current time to SW3L-LB. If SW3L-LB fails to get the time from the server, SW3L-LB will use the internal time and wait for next time request (AT+SYNCTDC to set the time request period, default is 10 days). 454 454 455 455 (% style="color:red" %)**Note: LoRaWAN Server need to support LoRaWAN v1.0.3(MAC v1.0.3) or higher to support this MAC command feature, Chirpstack,TTN V3 v3 and loriot support but TTN V3 v2 doesn't support. If server doesn't support this command, it will through away uplink packet with this command, so user will lose the packet with time request for TTN V3 v2 if SYNCMOD=1.** 456 456 457 457 458 -=== 2. 6.4 Poll sensor value ===639 +=== 2.5.4 Poll sensor value === 459 459 460 460 461 461 Users can poll sensor values based on timestamps. Below is the downlink command. ... ... @@ -478,24 +478,24 @@ 478 478 ))) 479 479 480 480 ((( 481 -Uplink Internal =5s,means DDS45-LB will send one packet every 5s. range 5~~255s.662 +Uplink Internal =5s,means SW3L-LB will send one packet every 5s. range 5~~255s. 482 482 ))) 483 483 484 484 485 -== 2. 7Frequency Plans ==666 +== 2.6 Frequency Plans == 486 486 487 487 488 -The DDS45-LB uses OTAA mode and below frequency plans by default. If user want to use it with different frequency plan, please refer the AT command sets.669 +The SW3L-LB uses OTAA mode and below frequency plans by default. If user want to use it with different frequency plan, please refer the AT command sets. 489 489 490 490 [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20Frequency%20Band/>>http://wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20Frequency%20Band/]] 491 491 492 492 493 -= 3. Configure DDS45-LB =674 += 3. Configure SW3L-LB = 494 494 495 495 == 3.1 Configure Methods == 496 496 497 497 498 - DDS45-LB supports below configure method:679 +SW3L-LB supports below configure method: 499 499 500 500 * AT Command via Bluetooth Connection (**Recommended**): [[BLE Configure Instruction>>http://wiki.dragino.com/xwiki/bin/view/Main/BLE%20Bluetooth%20Remote%20Configure/]]. 501 501 ... ... @@ -517,10 +517,10 @@ 517 517 [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/>>http://wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/]] 518 518 519 519 520 -== 3.3 Commands special design for DDS45-LB ==701 +== 3.3 Commands special design for SW3L-LB == 521 521 522 522 523 -These commands only valid for DDS45-LB, as below:704 +These commands only valid for SW3L-LB, as below: 524 524 525 525 526 526 === 3.3.1 Set Transmit Interval Time === ... ... @@ -562,147 +562,262 @@ 562 562 Example 1: Downlink Payload: 0100001E ~/~/ Set Transmit Interval (TDC) = 30 seconds 563 563 ))) 564 564 * ((( 565 -Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds 746 +Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds 566 566 ))) 567 567 749 +=== 3.3.2 Quit AT Command === 568 568 569 569 752 +Feature: Quit AT Command mode, so user needs to input the password again before using AT Commands. 570 570 571 - ===3.3.2 SetInterruptMode===754 +(% style="color:blue" %)**AT Command: AT+DISAT** 572 572 756 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:452px" %) 757 +|=(% style="width: 155px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 198px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 99px;background-color:#D9E2F3;color:#0070C0" %)**Response** 758 +|(% style="width:155px" %)AT+DISAT|(% style="width:198px" %)Quit AT Commands mode|(% style="width:96px" %)OK 573 573 574 - Feature,SetInterrupt modeforPA8of pin.760 +(% style="color:blue" %)**Downlink Command:** 575 575 576 - When AT+INTMOD=0isset,PA8isusedas a digital input port.762 +No downlink command for this feature. 577 577 578 -(% style="color:blue" %)**AT Command: AT+INTMOD** 579 579 580 -(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %) 581 -|=(% style="width: 155px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 197px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 158px;background-color:#D9E2F3;color:#0070C0" %)**Response** 582 -|(% style="width:154px" %)AT+INTMOD=?|(% style="width:196px" %)Show current interrupt mode|(% style="width:157px" %)((( 583 -0 584 -OK 585 -the mode is 0 =Disable Interrupt 765 +=== 3.3.3 Get Device Status === 766 + 767 + 768 +Send a LoRaWAN downlink to ask device send Alarm settings. 769 + 770 +(% style="color:blue" %)**Downlink Payload: **(%%)0x26 01 771 + 772 +Sensor will upload Device Status via FPORT=5. See payload section for detail. 773 + 774 + 775 +=== 3.3.4 Alarm for continuously water flow === 776 + 777 + 778 +((( 779 +This feature is to monitor and send Alarm for continuously water flow. 586 586 ))) 587 -|(% style="width:154px" %)AT+INTMOD=2|(% style="width:196px" %)((( 588 -Set Transmit Interval 589 -0. (Disable Interrupt), 590 -~1. (Trigger by rising and falling edge) 591 -2. (Trigger by falling edge) 592 -3. (Trigger by rising edge) 593 -)))|(% style="width:157px" %)OK 594 594 595 -(% style="color:blue" %)**Downlink Command: 0x06** 782 +((( 783 +Example case is for Toilet water monitoring, if some one push toilet button, the toilet will have water flow. If the toilet button has broken and can't returned to original state, the water flow will keep for hours or days which cause huge waste for water. 784 +))) 596 596 597 -Format: Command Code (0x06) followed by 3 bytes. 786 +((( 787 +To monitor this faulty and send alarm, there are two settings: 788 +))) 598 598 599 -This means that the interrupt mode of the end node is set to 0x000003=3 (rising edge trigger), and the type code is 06. 790 +* ((( 791 +(% style="color:#4f81bd" %)**Stop Duration: Unit: Second** 792 +))) 600 600 601 -* Example 1: Downlink Payload: 06000000 ~/~/ Turn off interrupt mode 794 +((( 795 +Default: 15s, If SW3L-LB didn't see any water flow in 15s, SW3L-LB will consider stop of water flow event. 796 +))) 602 602 603 -* Example 2: Downlink Payload: 06000003 ~/~/ Set the interrupt mode to rising edge trigger 798 +* ((( 799 +(% style="color:#4f81bd" %)**Alarm Timer: Units: Minute; Default 0 minutes (means Alarm disable)** 800 +))) 604 604 802 +((( 803 +**Example:** 3 minutes, if SW3L-LB detect a start of water flow event and didn't detect a stop event within Alarm timer, SW3L-LB will send an Alarm to indicate a water flow abnormal alarm. 804 +))) 605 605 806 +((( 807 +So for example, If we set stop duration=15s and Alarm Timer=3minutes. If the toilet water flow continuously for more than 3 minutes, Sensor will send an alarm (in Confirmed MODE) to platform. 808 +))) 606 606 810 +((( 811 +(% style="color:red" %)**Note:** **After this alarm is send, sensor will consider a stop of water flow and count for another new event. So if water flow waste last for 1 hour, Sensor will keep sending alarm every 3 minutes.** 812 +))) 607 607 608 -= 4. Battery & Power Consumption = 814 +((( 815 +(% style="color:#4f81bd" %)**AT Command**(%%) to configure: 816 +))) 609 609 818 +* ((( 819 +AT+PTRIG=15,3 ~-~-> Set Stop duration: 15s, Alarm Timer: 3 minutes. 820 +))) 610 610 611 -DDS45-LB use ER26500 + SPC1520 battery pack. See below link for detail information about the battery info and how to replace. 822 +* ((( 823 +AT+ PTRIG=15,0 ~-~-> Default Value, disable water waste Alarm. 824 +))) 612 612 613 -[[**Battery Info & Power Consumption Analyze**>>http://wiki.dragino.com/xwiki/bin/view/Main/How%20to%20calculate%20the%20battery%20life%20of%20Dragino%20sensors%3F/]] . 826 +((( 827 +(% style="color:#4f81bd" %)**Downlink Command**(%%) to configure: 828 +))) 614 614 830 +((( 831 +Command: **0xAA aa bb cc** 832 +))) 615 615 616 -= 5. OTA Firmware update = 834 +((( 835 +AA: Command Type Code 836 +))) 617 617 838 +((( 839 +aa: Stop duration 840 +))) 618 618 619 -(% class="wikigeneratedid" %) 620 -User can change firmware DDS45-LB to: 842 +((( 843 +bb cc: Alarm Timer 844 +))) 621 621 622 -* Change Frequency band/ region. 846 +((( 847 +If user send 0xAA 0F 00 03: equal to AT+PTRIG=15,3 848 +))) 623 623 624 -* Update with new features. 625 625 626 - *Fixbugs.851 +=== 3.3.5 Clear Flash Record === 627 627 628 -Firmware and changelog can be downloaded from : **[[Firmware download link>>url:https://www.dropbox.com/sh/a5ue0nfrzqy9nz6/AABbvlATosDJKDwBmbirVbMYa?dl=0]]** 629 629 630 - Methods toUpdateFirmware:854 +Feature: Clear flash storage for data log feature. 631 631 632 - *(Recommandedway) OTA firmware update via wireless: [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/Firmware%20OTA%20Update%20for%20Sensors/>>url:http://wiki.dragino.com/xwiki/bin/view/Main/Firmware%20OTA%20Update%20for%20Sensors/]]856 +(% style="color:blue" %)**AT Command: AT+CLRDTA** 633 633 634 -* Update through UART TTL interface: **[[Instruction>>url:http://wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H1.LoRaSTv4baseHardware]]**. 858 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:500px" %) 859 +|=(% style="width: 157px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 169px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 174px;background-color:#D9E2F3;color:#0070C0" %)**Response** 860 +|(% style="width:157px" %)AT+CLRDTA|(% style="width:169px" %)Clear flash storage for data log feature.|Clear all stored sensor data… OK 635 635 862 +((( 863 +(% style="color:blue" %)**Downlink Command:** 864 +))) 636 636 866 +((( 867 +* **Example**: 0xA301 ~/~/ Same as AT+CLRDTA 868 +))) 637 637 638 638 639 639 640 -= 6.FAQ=872 +=== 3.3.6 Set the calculate flag === 641 641 642 -== 6.1 What is the frequency plan for DDS45-LB? == 643 643 875 +Feature: Set the calculate flag 644 644 645 - DDS45-LBusethesame frequency asother Draginoproducts. Usercansee the detail fromthis link: [[Introduction>>doc:Main.EndDeviceFrequency Band.WebHome||anchor="H1.Introduction"]]877 +(% style="color:blue" %)**AT Command: AT+CALCFLAG** 646 646 879 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:461px" %) 880 +|=(% style="width: 158px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 193px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 110px;background-color:#D9E2F3;color:#0070C0" %)**Response** 881 +|(% style="width:158px" %)AT+CALCFLAG =1|(% style="width:192px" %)Set the calculate flag to 1.|(% style="width:109px" %)OK 882 +|(% style="width:158px" %)AT+CALCFLAG =2|(% style="width:192px" %)Set the calculate flag to 2.|(% style="width:109px" %)OK 647 647 648 - ==6.2 Can I use DDS45-LB in condensationenvironment? ==884 +(% style="color:blue" %)**Downlink Command:** 649 649 886 +* **Example**: 0XA501 ~/~/ Same as AT+CALCFLAG =1 650 650 651 - DDS45-LBisnot suitableobe used incondensationenvironment. Condensation on the DDS45-LB probewill affect thereadingand always got 0.888 +=== 3.3.7 Set count number === 652 652 653 653 654 - = 7. TroubleShooting=891 +Feature: Manually set the count number 655 655 656 - ==7.1 WhyIcan't joinTTNV3 in US915 / AU915 bands?==893 +(% style="color:blue" %)**AT Command: AT+SETCNT** 657 657 895 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:479px" %) 896 +|=(% style="width: 160px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 223px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 96px;background-color:#D9E2F3;color:#0070C0" %)**Response** 897 +|(% style="width:160px" %)AT+ SETCNT =0|(% style="width:221px" %)Set the count number to 0.|(% style="width:95px" %)OK 898 +|(% style="width:160px" %)AT+ SETCNT =100|(% style="width:221px" %)Set the count number to 100.|(% style="width:95px" %)OK 658 658 659 - Itisdueto channelmapping. Pleasesee below: [[Frequencyband>>doc:Main.LoRaWANCommunicationDebug.WebHome||anchor="H2.NoticeofUS9152FCN4702FAU915Frequencyband"]]900 +(% style="color:blue" %)**Downlink Command:** 660 660 902 +* **Example**: 0xA6000001 ~/~/ Same as AT+ SETCNT =1 661 661 662 - ==7.2ATCommandinputdoesn'twork==904 +* **Example**: 0xA6000064 ~/~/ Same as AT+ SETCNT =100 663 663 906 +=== 3.3.8 Set Interrupt Mode === 664 664 665 -In the case if user can see the console output but can't type input to the device. Please check if you already include the (% style="color:blue" %)**ENTER**(%%) while sending out the command. Some serial tool doesn't send (% style="color:blue" %)**ENTER**(%%) while press the send key, user need to add ENTER in their string. 666 666 909 +Feature, Set Interrupt mode for PA8 of pin. 667 667 668 - == 7.3Why doesthe sensorreadingshow0or"No sensor" ==911 +When AT+INTMOD=0 is set, PA8 is used as a digital input port. 669 669 913 +(% style="color:blue" %)**AT Command: AT+INTMOD** 670 670 671 -~1. The measurement object is very close to the sensor, but in the blind spot of the sensor. 915 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %) 916 +|=(% style="width: 155px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 197px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 158px;background-color:#D9E2F3;color:#0070C0" %)**Response** 917 +|(% style="width:154px" %)AT+INTMOD=?|(% style="width:196px" %)Show current interrupt mode|(% style="width:157px" %)((( 918 +0 919 +OK 920 +the mode is 0 =Disable Interrupt 921 +))) 922 +|(% style="width:154px" %)AT+INTMOD=2|(% style="width:196px" %)((( 923 +Set Transmit Interval 924 +0. (Disable Interrupt), 925 +~1. (Trigger by rising and falling edge) 926 +2. (Trigger by falling edge) 927 +3. (Trigger by rising edge) 928 +)))|(% style="width:157px" %)OK 672 672 673 - 2.Sensor wiringis disconnected930 +(% style="color:blue" %)**Downlink Command: 0x06** 674 674 675 - 3. Notusingthecorrectdecoder932 +Format: Command Code (0x06) followed by 3 bytes. 676 676 934 +This means that the interrupt mode of the end node is set to 0x000003=3 (rising edge trigger), and the type code is 06. 677 677 678 - ==7.4 AbnormalreadingsThegap betweenmultiplereadingsistoolargeorthegapbetweenthereadings andtheactual value istoolarge==936 +* Example 1: Downlink Payload: 06000000 ~/~/ Turn off interrupt mode 679 679 938 +* Example 2: Downlink Payload: 06000003 ~/~/ Set the interrupt mode to rising edge trigger 680 680 681 - 1)Pleasecheck ifthereis something on the probeaffecting itsmeasurement (condensedwater, volatile oil, etc.)940 +=== 3.3.9 Set work mode === 682 682 683 -2) Does it change with temperature, temperature will affect its measurement 684 684 685 - 3) Ifabnormal data occurs,you canturn on DEBUG mode, PleaseusedownlinkorAT COMMAN to enter DEBUGmode.943 +Feature: Manually set the work mode 686 686 687 -downlink command: (% style="color:blue" %)**F1 01**(%%), AT command: (% style="color:blue" %)**AT+DDEBUG=1** 688 688 689 - 4)Afterentering the debug mode,itwill send 20 piecesof data at a time,andyou can send its uplink to us for analysis946 +(% style="color:blue" %)**AT Command: AT+MOD** 690 690 691 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDDS75%20-%20LoRaWAN%20Distance%20Detection%20Sensor%20User%20Manual/WebHome/image-20230113135125-2.png?width=1057&height=136&rev=1.1||alt="image-20230113135125-2.png"]] 948 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:463px" %) 949 +|=(% style="width: 162px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 193px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 108px;background-color:#D9E2F3;color:#0070C0" %)**Response** 950 +|(% style="width:162px" %)AT+MOD=0|(% style="width:191px" %)Set the work mode to 0.|(% style="width:106px" %)OK 951 +|(% style="width:162px" %)AT+MOD=1|(% style="width:191px" %)Set the work mode to 1|(% style="width:106px" %)OK 692 692 953 +(% style="color:blue" %)**Downlink Command:** 693 693 694 - Itsoriginalpayload will belongerthanotherdata.Eventhoughitis being parsed,it can beseenthat it is abnormal data.955 +* **Example: **0x0A00 ~/~/ Same as AT+MOD=0 695 695 696 - Pleasesendthedatatousforcheck.957 +* **Example:** 0x0A01 ~/~/ Same as AT+MOD=1 697 697 959 += 4. Battery & Power Consumption = 698 698 699 -= 8. Order Info = 700 700 962 +SW3L-LB use ER26500 + SPC1520 battery pack. See below link for detail information about the battery info and how to replace. 701 701 702 - PartNumber: (%style="color:blue"%)**DDS45-LB-XXX**964 +[[**Battery Info & Power Consumption Analyze**>>http://wiki.dragino.com/xwiki/bin/view/Main/How%20to%20calculate%20the%20battery%20life%20of%20Dragino%20sensors%3F/]] . 703 703 704 -(% style="color:red" %)**XXX**(%%): **The default frequency band** 705 705 967 += 5. OTA Firmware update = 968 + 969 + 970 +(% class="wikigeneratedid" %) 971 +User can change firmware SW3L-LB to: 972 + 973 +* Change Frequency band/ region. 974 + 975 +* Update with new features. 976 + 977 +* Fix bugs. 978 + 979 +Firmware and changelog can be downloaded from : **[[Firmware download link>>url:https://www.dropbox.com/sh/kwqv57tp6pejias/AAAopYMATh1GM6fZ-VRCLrpDa?dl=0]]** 980 + 981 +Methods to Update Firmware: 982 + 983 +* (Recommanded way) OTA firmware update via wireless: [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/Firmware%20OTA%20Update%20for%20Sensors/>>url:http://wiki.dragino.com/xwiki/bin/view/Main/Firmware%20OTA%20Update%20for%20Sensors/]] 984 + 985 +* Update through UART TTL interface. **[[Instruction>>url:http://wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H1.LoRaSTv4baseHardware]]**. 986 + 987 += 6. FAQ = 988 + 989 +== 6.1 AT Commands input doesn't work == 990 + 991 + 992 +In the case if user can see the console output but can't type input to the device. Please check if you already include the (% style="color:green" %)**ENTER**(%%) while sending out the command. Some serial tool doesn't send (% style="color:green" %)**ENTER**(%%) while press the send key, user need to add ENTER in their string. 993 + 994 + 995 += 7. Order Info = 996 + 997 + 998 +Part Number: (% style="color:blue" %)**SW3L-LB-XXX-YYY** 999 + 1000 +(% style="color:red" %)**XXX**(%%): The default frequency band 1001 + 706 706 * (% style="color:red" %)**AS923**(%%): LoRaWAN AS923 band 707 707 708 708 * (% style="color:red" %)**AU915**(%%): LoRaWAN AU915 band ... ... @@ -719,12 +719,43 @@ 719 719 720 720 * (% style="color:red" %)**CN470**(%%): LoRaWAN CN470 band 721 721 722 -= 9. Packing Info = 1018 +((( 1019 +(% style="color:blue" %)**YYY**(%%): Flow Sensor Model: 1020 +))) 723 723 1022 +((( 1023 + **004:** DW-004 Flow Sensor: diameter: G1/2” / DN15. 450 pulse = 1 L 1024 +))) 724 724 1026 +((( 1027 + **006:** DW-006 Flow Sensor: diameter: G3/4” / DN20. 390 pulse = 1 L 1028 +))) 1029 + 1030 +((( 1031 + **010:** DW-010 Flow Sensor: diameter: G 1” / DN25. 64 pulse = 1 L 1032 +))) 1033 + 1034 +* ((( 1035 +calculate flag=0: for SW3L-004 Flow Sensor: 450 pulse = 1 L 1036 +))) 1037 + 1038 +* ((( 1039 +calculate flag=1: for SW3L-006 Flow Sensor: 390 pulse = 1 L 1040 +))) 1041 + 1042 +* ((( 1043 +calculate flag=2: for SW3L-010 Flow Sensor: 64 pulse = 1 L 1044 + 1045 + 1046 + 1047 +))) 1048 + 1049 += 8. Packing Info = 1050 + 1051 + 725 725 (% style="color:#037691" %)**Package Includes**: 726 726 727 -* DDS45-LB LoRaWANDistance DetectionSensorx 11054 +* SW3L-LB LoRaWAN Flow Sensor 728 728 729 729 (% style="color:#037691" %)**Dimension and weight**: 730 730 ... ... @@ -736,7 +736,7 @@ 736 736 737 737 * Weight / pcs : g 738 738 739 -= 10. Support =1066 += 9. Support = 740 740 741 741 742 742 * Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule.
- image-20230613100900-1.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -184.0 KB - Content
- image-20230613102426-2.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -89.3 KB - Content
- image-20230613102459-3.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -89.3 KB - Content