Changes for page DS20L -- LoRaWAN Smart Distance Detector User Manual 01
Last modified by Mengting Qiu on 2023/12/14 11:15
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 3 removed)
Details
- Page properties
-
- Title
-
... ... @@ -1,1 +1,1 @@ 1 -DDS 20-LB -- LoRaWANUltrasonicLiquid LevelSensor User Manual1 +DDS75-LB -- LoRaWAN Distance Detection Sensor User Manual - Content
-
... ... @@ -1,8 +1,9 @@ 1 1 (% style="text-align:center" %) 2 -[[image:image-2023061 3100900-1.png||height="650" width="650"]]2 +[[image:image-20230612170349-1.png||height="656" width="656"]] 3 3 4 4 5 5 6 + 6 6 **Table of Contents:** 7 7 8 8 {{toc/}} ... ... @@ -17,19 +17,19 @@ 17 17 == 1.1 What is LoRaWAN Distance Detection Sensor == 18 18 19 19 20 -The Dragino DDS 45-LB is a (% style="color:blue" %)** LoRaWAN Distance Detection Sensor**(%%) for Internet of Things solution. It is used to measure the distance between the sensor and a flat object. The distance detection sensor is a module that uses (% style="color:blue" %)** ultrasonic sensing technology**(%%) for (% style="color:blue" %)**distance measurement**(%%), and (% style="color:blue" %)** temperature compensation**(%%) is performed internally to improve the reliability of data. The DDS45-LB can be applied to scenarios such as horizontal distance measurement, liquid level measurement, parking management system, object proximity and presence detection, intelligent trash can management system, robot obstacle avoidance, automatic control, sewer, bottom water level monitoring, etc.21 +The Dragino DDS75-LB is a (% style="color:blue" %)** LoRaWAN Distance Detection Sensor**(%%) for Internet of Things solution. It is used to measure the distance between the sensor and a flat object. The distance detection sensor is a module that uses (% style="color:blue" %)** ultrasonic sensing technology**(%%) for (% style="color:blue" %)**distance measurement**(%%), and (% style="color:blue" %)** temperature compensation**(%%) is performed internally to improve the reliability of data. The DDS75-LB can be applied to scenarios such as horizontal distance measurement, liquid level measurement, parking management system, object proximity and presence detection, intelligent trash can management system, robot obstacle avoidance, automatic control, sewer, bottom water level monitoring, etc. 21 21 22 22 It detects the distance(% style="color:blue" %)** between the measured object and the sensor**(%%), and uploads the value via wireless to LoRaWAN IoT Server. 23 23 24 -The LoRa wireless technology used in DDS45-LB allows device to send data and reach extremely long ranges at low data-rates. It provides ultra-long range spread spectrum communication and high interference immunity whilst minimizing current consumption.25 +The LoRa wireless technology used in SW3L-LB allows device to send data and reach extremely long ranges at low data-rates. It provides ultra-long range spread spectrum communication and high interference immunity whilst minimizing current consumption. 25 25 26 - DDS45-LB (% style="color:blue" %)**supports BLE configure**(%%) and (% style="color:blue" %)**wireless OTA update**(%%) which make user easy to use.27 +SW3L-LB (% style="color:blue" %)**supports BLE configure**(%%) and (% style="color:blue" %)**wireless OTA update**(%%) which make user easy to use. 27 27 28 - DDS45-LB is powered by (% style="color:blue" %)**8500mAh Li-SOCI2 battery**(%%), it is designed for long term use up to 5 years.29 +SW3L-LB is powered by (% style="color:blue" %)**8500mAh Li-SOCI2 battery**(%%), it is designed for long term use up to 5 years. 29 29 30 -Each DDS45-LB is pre-load with a set of unique keys for LoRaWAN registrations, register these keys to local LoRaWAN server and it will auto connect after power on.31 +Each SW3L-LB is pre-load with a set of unique keys for LoRaWAN registrations, register these keys to local LoRaWAN server and it will auto connect after power on. 31 31 32 -[[image:image-2023061 3102459-3.png||height="476" width="855"]]33 +[[image:image-20230612170943-2.png||height="525" width="912"]] 33 33 34 34 35 35 == 1.2 Features == ... ... @@ -39,9 +39,8 @@ 39 39 * Bands: CN470/EU433/KR920/US915/EU868/AS923/AU915/IN865 40 40 * Ultra-low power consumption 41 41 * Distance Detection by Ultrasonic technology 42 -* Flat object range 30mm -4500mm43 +* Flat object range 280mm - 7500mm 43 43 * Accuracy: ±(1cm+S*0.3%) (S: Distance) 44 -* Measure Angle: 60° 45 45 * Cable Length : 25cm 46 46 * Support Bluetooth v5.1 and LoRaWAN remote configure 47 47 * Support wireless OTA update firmware ... ... @@ -50,10 +50,36 @@ 50 50 * IP66 Waterproof Enclosure 51 51 * 8500mAh Battery for long term use 52 52 53 - 54 54 == 1.3 Specification == 55 55 56 56 56 +(% style="color:#037691" %)**Rated environmental conditions:** 57 + 58 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:500px" %) 59 +|(% style="background-color:#d9e2f3; color:#0070c0; width:163px" %)**Item**|(% style="background-color:#d9e2f3; color:#0070c0; width:90px" %)((( 60 +**Minimum value** 61 +)))|(% style="background-color:#d9e2f3; color:#0070c0; width:70px" %)((( 62 +**Typical value** 63 +)))|(% style="background-color:#d9e2f3; color:#0070c0; width:87px" %)((( 64 +**Maximum value** 65 +)))|(% style="background-color:#d9e2f3; color:#0070c0; width:40px" %)**Unit**|(% style="background-color:#d9e2f3; color:#0070c0; width:50px" %)**Remarks** 66 +|(% style="width:174px" %)Storage temperature|(% style="width:86px" %)-25|(% style="width:66px" %)25|(% style="width:90px" %)80|(% style="width:48px" %)℃|(% style="width:203px" %) 67 +|(% style="width:174px" %)Storage humidity|(% style="width:86px" %) |(% style="width:66px" %)65%|(% style="width:90px" %)90%|(% style="width:48px" %)RH|(% style="width:203px" %)(1) 68 +|(% style="width:174px" %)Operating temperature|(% style="width:86px" %)-15|(% style="width:66px" %)25|(% style="width:90px" %)60|(% style="width:48px" %)℃|(% style="width:203px" %) 69 +|(% style="width:174px" %)Working humidity|(% style="width:86px" %)((( 70 + 71 + 72 + 73 +)))|(% style="width:66px" %)65%|(% style="width:90px" %)80%|(% style="width:48px" %)RH|(% style="width:203px" %)(1) 74 + 75 +((( 76 +**Remarks: (1) a. When the ambient temperature is 0-39 ℃, the maximum humidity is 90% (non-condensing); ** 77 + 78 +**~ b. When the ambient temperature is 40-50 ℃, the highest humidity is the highest humidity in the natural world at the current temperature (no condensation)** 79 + 80 + 81 +))) 82 + 57 57 (% style="color:#037691" %)**Common DC Characteristics:** 58 58 59 59 * Supply Voltage: built in 8500mAh Li-SOCI2 battery , 2.5v ~~ 3.6v ... ... @@ -79,49 +79,20 @@ 79 79 * Sleep Mode: 5uA @ 3.3v 80 80 * LoRa Transmit Mode: 125mA @ 20dBm, 82mA @ 14dBm 81 81 108 +== 1.4 Effective measurement range Reference beam pattern == 82 82 83 -== 1.4 Rated environmental conditions == 84 84 111 +**~1. The tested object is a white cylindrical tube made of PVC, with a height of 100cm and a diameter of 7.5cm.** 85 85 86 -(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:500px" %) 87 -|(% style="background-color:#d9e2f3; color:#0070c0; width:163px" %)**Item**|(% style="background-color:#d9e2f3; color:#0070c0; width:90px" %)((( 88 -**Minimum value** 89 -)))|(% style="background-color:#d9e2f3; color:#0070c0; width:70px" %)((( 90 -**Typical value** 91 -)))|(% style="background-color:#d9e2f3; color:#0070c0; width:87px" %)((( 92 -**Maximum value** 93 -)))|(% style="background-color:#d9e2f3; color:#0070c0; width:40px" %)**Unit**|(% style="background-color:#d9e2f3; color:#0070c0; width:50px" %)**Remarks** 94 -|(% style="width:174px" %)Storage temperature|(% style="width:86px" %)-25|(% style="width:66px" %)25|(% style="width:90px" %)80|(% style="width:48px" %)℃|(% style="width:203px" %) 95 -|(% style="width:174px" %)Storage humidity|(% style="width:86px" %) |(% style="width:66px" %)65%|(% style="width:90px" %)90%|(% style="width:48px" %)RH|(% style="width:203px" %)(1) 96 -|(% style="width:174px" %)Operating temperature|(% style="width:86px" %)-15|(% style="width:66px" %)25|(% style="width:90px" %)60|(% style="width:48px" %)℃|(% style="width:203px" %) 97 -|(% style="width:174px" %)Working humidity|(% style="width:86px" %)((( 98 - 99 - 100 - 101 -)))|(% style="width:66px" %)65%|(% style="width:90px" %)80%|(% style="width:48px" %)RH|(% style="width:203px" %)(1) 102 - 103 -((( 104 -(% style="color:red" %)**Remarks: (1) a. When the ambient temperature is 0-39 ℃, the maximum humidity is 90% (non-condensing); ** 105 - 106 -(% style="color:red" %)** b. When the ambient temperature is 40-50 ℃, the highest humidity is the highest humidity in the natural world at the current temperature (no condensation)** 107 - 108 - 109 -))) 110 - 111 -== 1.5 Effective measurement range Reference beam pattern == 112 - 113 - 114 -(% style="color:blue" %)**1. The tested object is a white cylindrical tube made of PVC, with a height of 100cm and a diameter of 7.5cm.** 115 - 116 116 [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDDS75%20-%20LoRaWAN%20Distance%20Detection%20Sensor%20User%20Manual/WebHome/1654852253176-749.png?rev=1.1||alt="1654852253176-749.png"]] 117 117 118 118 119 - (% style="color:blue" %)**2. The object to be tested is a "corrugated cardboard box" perpendicular to the central axis of 0 °, and the length * width is 60cm * 50cm.**116 +**2. The object to be tested is a "corrugated cardboard box" perpendicular to the central axis of 0 °, and the length * width is 60cm * 50cm.** 120 120 121 121 [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDDS75%20-%20LoRaWAN%20Distance%20Detection%20Sensor%20User%20Manual/WebHome/1654852175653-550.png?rev=1.1||alt="1654852175653-550.png"]] 122 122 123 123 124 -== 1. 6Applications ==121 +== 1.5 Applications == 125 125 126 126 127 127 * Horizontal distance measurement ... ... @@ -134,16 +134,15 @@ 134 134 * Sewer 135 135 * Bottom water level monitoring 136 136 134 +== 1.6 Sleep mode and working mode == 137 137 138 -== 1.7 Sleep mode and working mode == 139 139 140 - 141 141 (% style="color:blue" %)**Deep Sleep Mode: **(%%)Sensor doesn't have any LoRaWAN activate. This mode is used for storage and shipping to save battery life. 142 142 143 143 (% style="color:blue" %)**Working Mode:** (%%)In this mode, Sensor will work as LoRaWAN Sensor to Join LoRaWAN network and send out sensor data to server. Between each sampling/tx/rx periodically, sensor will be in IDLE mode), in IDLE mode, sensor has the same power consumption as Deep Sleep mode. 144 144 145 145 146 -== 1. 8Button & LEDs ==142 +== 1.7 Button & LEDs == 147 147 148 148 149 149 [[image:Main.User Manual for LoRaWAN End Nodes.D20-LBD22-LBD23-LB_LoRaWAN_Temperature_Sensor_User_Manual.WebHome@1675071855856-879.png]] ... ... @@ -162,13 +162,12 @@ 162 162 ))) 163 163 |(% style="width:167px" %)Fast press ACT 5 times.|(% style="width:117px" %)Deactivate Device|(% style="width:225px" %)(% style="color:red" %)**Red led**(%%) will solid on for 5 seconds. Means device is in Deep Sleep Mode. 164 164 161 +== 1.8 BLE connection == 165 165 166 -== 1.9 BLE connection == 167 167 164 +DDS75-LB support BLE remote configure. 168 168 169 -DDS45-LB support BLE remote configure. 170 170 171 - 172 172 BLE can be used to configure the parameter of sensor or see the console output from sensor. BLE will be only activate on below case: 173 173 174 174 * Press button to send an uplink ... ... @@ -178,14 +178,16 @@ 178 178 If there is no activity connection on BLE in 60 seconds, sensor will shut down BLE module to enter low power mode. 179 179 180 180 181 -== 1. 10Pin Definitions ==176 +== 1.9 Pin Definitions == 182 182 183 183 [[image:image-20230523174230-1.png]] 184 184 185 185 186 -== 1.11Mechanical==181 +== == 187 187 183 +== 2.10 Mechanical == 188 188 185 + 189 189 [[image:Main.User Manual for LoRaWAN End Nodes.D20-LBD22-LBD23-LB_LoRaWAN_Temperature_Sensor_User_Manual.WebHome@1675143884058-338.png]] 190 190 191 191 ... ... @@ -195,17 +195,24 @@ 195 195 [[image:Main.User Manual for LoRaWAN End Nodes.D20-LBD22-LBD23-LB_LoRaWAN_Temperature_Sensor_User_Manual.WebHome@1675143909447-639.png]] 196 196 197 197 198 - (% style="color:blue" %)**Probe Mechanical:**195 +**Probe Mechanical:** 199 199 200 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDDS45%20-%20LoRaWAN%20Distance%20Detection%20Sensor%20User%20Manual/WebHome/1654915562090-396.png?rev=1.1||alt="1654915562090-396.png"]] 201 201 198 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDDS75%20-%20LoRaWAN%20Distance%20Detection%20Sensor%20User%20Manual/WebHome/image-20220610172003-1.png?rev=1.1||alt="image-20220610172003-1.png"]] 202 202 203 -= 2. Configure DDS45-LB to connect to LoRaWAN network = 204 204 201 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDDS75%20-%20LoRaWAN%20Distance%20Detection%20Sensor%20User%20Manual/WebHome/image-20220610172003-2.png?rev=1.1||alt="image-20220610172003-2.png"]] 202 + 203 + 204 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDDS75%20-%20LoRaWAN%20Distance%20Detection%20Sensor%20User%20Manual/WebHome/image-20220610172003-2.png?rev=1.1||alt="image-20220610172003-2.png"]] 205 + 206 + 207 += 2. Configure DDS75-LB to connect to LoRaWAN network = 208 + 205 205 == 2.1 How it works == 206 206 207 207 208 -The DDS 45-LB is configured as (% style="color:#037691" %)**LoRaWAN OTAA Class A**(%%) mode by default. It has OTAA keys to join LoRaWAN network. To connect a local LoRaWAN network, you need to input the OTAA keys in the LoRaWAN IoT server and press the button to activate the DDS45-LB. It will automatically join the network via OTAA and start to send the sensor value. The default uplink interval is 20 minutes.212 +The DDS75-LB is configured as (% style="color:#037691" %)**LoRaWAN OTAA Class A**(%%) mode by default. It has OTAA keys to join LoRaWAN network. To connect a local LoRaWAN network, you need to input the OTAA keys in the LoRaWAN IoT server and press the button to activate the DDS75-LB. It will automatically join the network via OTAA and start to send the sensor value. The default uplink interval is 20 minutes. 209 209 210 210 (% style="display:none" %) (%%) 211 211 ... ... @@ -216,12 +216,12 @@ 216 216 217 217 The LPS8v2 is already set to connected to [[TTN network >>url:https://console.cloud.thethings.network/]], so what we need to now is configure the TTN server. 218 218 219 -[[image:image-2023061 3102426-2.png||height="476" width="855"]](% style="display:none" %)223 +[[image:image-20230612171032-3.png||height="492" width="855"]](% style="display:none" %) 220 220 221 221 222 -(% style="color:blue" %)**Step 1:**(%%) Create a device in TTN with the OTAA keys from DDS 45-LB.226 +(% style="color:blue" %)**Step 1:**(%%) Create a device in TTN with the OTAA keys from DDS75-LB. 223 223 224 -Each DDS 45-LB is shipped with a sticker with the default device EUI as below:228 +Each DDS75-LB is shipped with a sticker with the default device EUI as below: 225 225 226 226 [[image:image-20230426084152-1.png||alt="图片-20230426084152-1.png" height="233" width="502"]] 227 227 ... ... @@ -250,10 +250,10 @@ 250 250 [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LSN50v2-S31-S31B%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20User%20Manual/WebHome/image-20220611161308-6.png?width=744&height=485&rev=1.1||alt="图片-20220611161308-6.png"]] 251 251 252 252 253 -(% style="color:blue" %)**Step 2:**(%%) Activate on DDS 45-LB257 +(% style="color:blue" %)**Step 2:**(%%) Activate on DDS75-LB 254 254 255 255 256 -Press the button for 5 seconds to activate the DDS 45-LB.260 +Press the button for 5 seconds to activate the DDS75-LB. 257 257 258 258 (% style="color:green" %)**Green led**(%%) will fast blink 5 times, device will enter (% style="color:blue" %)**OTA mode**(%%) for 3 seconds. And then start to JOIN LoRaWAN network. (% style="color:green" %)**Green led**(%%) will solidly turn on for 5 seconds after joined in network. 259 259 ... ... @@ -264,13 +264,20 @@ 264 264 265 265 266 266 ((( 267 -DDS45-LB will uplink payload via LoRaWAN with below payload format: 271 +((( 272 +DDS75-LB will uplink payload via LoRaWAN with below payload format: 268 268 ))) 269 269 270 270 ((( 271 -Uplink payload includes in total 8 bytes. 276 +Uplink payload includes in total 4 bytes. 277 +Payload for firmware version v1.1.4. . Before v1.1.3, there is on two fields: BAT and Distance 272 272 ))) 279 +))) 273 273 281 +((( 282 + 283 +))) 284 + 274 274 (% border="1" cellspacing="5" style="background-color:#f2f2f2; width:510px" %) 275 275 |=(% style="width: 62.5px;background-color:#D9E2F3;color:#0070C0" %)((( 276 276 **Size(bytes)** ... ... @@ -288,7 +288,7 @@ 288 288 === 2.3.1 Battery Info === 289 289 290 290 291 -Check the battery voltage for DDS 45-LB.302 +Check the battery voltage for DDS75-LB. 292 292 293 293 Ex1: 0x0B45 = 2885mV 294 294 ... ... @@ -299,23 +299,23 @@ 299 299 300 300 301 301 ((( 302 -Get the distance. Flat object range 30mm -4500mm.313 +Get the distance. Flat object range 280mm - 7500mm. 303 303 ))) 304 304 305 305 ((( 306 -For example, if the data you get from the register is **0x0B 0x05**, the distance between the sensor and the measured object is(% style="color:#4472c4" %)** **317 +For example, if the data you get from the register is 0x0B 0x05, the distance between the sensor and the measured object is(% style="color:#4472c4" %)** ** 307 307 308 -(% style="color: blue" %)**0B05(H) = 2821 (D) = 2821 mm.**319 +(% style="color:#4472c4" %)**0B05(H) = 2821 (D) = 2821 mm.** 309 309 ))) 310 310 322 + 311 311 * If the sensor value is 0x0000, it means system doesn't detect ultrasonic sensor. 312 -* If the sensor value lower than 0x0 01E(30mm), the sensor value will be 0x00.324 +* If the sensor value lower than 0x0118 (280mm), the sensor value will be invalid. Since v1.1.4, all value lower than 280mm will be set to 0x0014(20mm) which means the value is invalid. 313 313 314 - 315 315 === 2.3.3 Interrupt Pin === 316 316 317 317 318 -This data field shows if this packet is generated by interrupt or not. [[Click here>>||anchor="H3.3 .2SetInterruptMode"]] for the hardware and software set up.329 +This data field shows if this packet is generated by interrupt or not. [[Click here>>||anchor="H3.3A0SetInterruptMode"]] for the hardware and software set up. 319 319 320 320 **Example:** 321 321 ... ... @@ -335,7 +335,9 @@ 335 335 336 336 If payload is: FF3FH : (FF3F & FC00 == 1) , temp = (FF3FH - 65536)/10 = -19.3 degrees. 337 337 349 +(% style="color:red" %)**Note: DS18B20 feature is supported in the hardware version > v1.3 which made since early of 2021.** 338 338 351 + 339 339 === 2.3.5 Sensor Flag === 340 340 341 341 ... ... @@ -358,7 +358,7 @@ 358 358 The payload decoder function for TTN V3 is here: 359 359 360 360 ((( 361 -DDS 45-LB TTN V3 Payload Decoder: [[ttps:~~/~~/github.com/dragino/dragino-end-node-decoder>>https://github.com/dragino/dragino-end-node-decoder]]374 +DDS75-LB TTN V3 Payload Decoder: [[ttps:~~/~~/github.com/dragino/dragino-end-node-decoder>>https://github.com/dragino/dragino-end-node-decoder]] 362 362 ))) 363 363 364 364 ... ... @@ -365,7 +365,7 @@ 365 365 == 2.4 Uplink Interval == 366 366 367 367 368 -The DDS 45-LB by default uplink the sensor data every 20 minutes. User can change this interval by AT Command or LoRaWAN Downlink Command. See this link: [[Change Uplink Interval>>||anchor="H3.3.1SetTransmitIntervalTime"]]381 +The DDS75-LB by default uplink the sensor data every 20 minutes. User can change this interval by AT Command or LoRaWAN Downlink Command. See this link: [[Change Uplink Interval>>doc:Main.End Device AT Commands and Downlink Command.WebHome||anchor="H4.1ChangeUplinkInterval"]] 369 369 370 370 371 371 == 2.5 Show Data in DataCake IoT Server == ... ... @@ -375,6 +375,9 @@ 375 375 [[DATACAKE>>url:https://datacake.co/]] provides a human friendly interface to show the sensor data, once we have data in TTN, we can use [[DATACAKE>>url:https://datacake.co/]] to connect to TTN and see the data in DATACAKE. Below are the steps: 376 376 ))) 377 377 391 +((( 392 + 393 +))) 378 378 379 379 ((( 380 380 (% style="color:blue" %)**Step 1**(%%)**: Be sure that your device is programmed and properly connected to the network at this time.** ... ... @@ -393,7 +393,7 @@ 393 393 394 394 (% style="color:blue" %)**Step 3**(%%)**: Create an account or log in Datacake.** 395 395 396 -(% style="color:blue" %)**Step 4**(%%)**: Search the DDS 45-LB and add DevEUI.**412 +(% style="color:blue" %)**Step 4**(%%)**: Search the DDS75-LB and add DevEUI.** 397 397 398 398 [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDDS75%20-%20LoRaWAN%20Distance%20Detection%20Sensor%20User%20Manual/WebHome/1654851029373-510.png?rev=1.1||alt="1654851029373-510.png"]] 399 399 ... ... @@ -407,19 +407,19 @@ 407 407 == 2.6 Datalog Feature == 408 408 409 409 410 -Datalog Feature is to ensure IoT Server can get all sampling data from Sensor even if the LoRaWAN network is down. For each sampling, DDS45-LB will store the reading for future retrieving purposes.426 +Datalog Feature is to ensure IoT Server can get all sampling data from Sensor even if the LoRaWAN network is down. For each sampling, SW3L-LB will store the reading for future retrieving purposes. 411 411 412 412 413 413 === 2.6.1 Ways to get datalog via LoRaWAN === 414 414 415 415 416 -Set PNACKMD=1, DDS45-LB will wait for ACK for every uplink, when there is no LoRaWAN network,DDS45-LB will mark these records with non-ack messages and store the sensor data, and it will send all messages (10s interval) after the network recovery.432 +Set PNACKMD=1, SW3L-LB will wait for ACK for every uplink, when there is no LoRaWAN network,SW3L-LB will mark these records with non-ack messages and store the sensor data, and it will send all messages (10s interval) after the network recovery. 417 417 418 418 * ((( 419 -a) DDS45-LB will do an ACK check for data records sending to make sure every data arrive server.435 +a) SW3L-LB will do an ACK check for data records sending to make sure every data arrive server. 420 420 ))) 421 421 * ((( 422 -b) DDS45-LB will send data in **CONFIRMED Mode** when PNACKMD=1, butDDS45-LB won't re-transmit the packet if it doesn't get ACK, it will just mark it as a NONE-ACK message. In a future uplink ifDDS45-LB gets a ACK,DDS45-LB will consider there is a network connection and resend all NONE-ACK messages.438 +b) SW3L-LB will send data in **CONFIRMED Mode** when PNACKMD=1, but SW3L-LB won't re-transmit the packet if it doesn't get ACK, it will just mark it as a NONE-ACK message. In a future uplink if SW3L-LB gets a ACK, SW3L-LB will consider there is a network connection and resend all NONE-ACK messages. 423 423 ))) 424 424 425 425 Below is the typical case for the auto-update datalog feature (Set PNACKMD=1) ... ... @@ -430,7 +430,7 @@ 430 430 === 2.6.2 Unix TimeStamp === 431 431 432 432 433 - DDS45-LB uses Unix TimeStamp format based on449 +SW3L-LB uses Unix TimeStamp format based on 434 434 435 435 [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/WebHome/image-20220523001219-11.png?width=627&height=97&rev=1.1||alt="图片-20220523001219-11.png" height="97" width="627"]] 436 436 ... ... @@ -449,7 +449,7 @@ 449 449 450 450 User need to set (% style="color:blue" %)**SYNCMOD=1**(%%) to enable sync time via MAC command. 451 451 452 -Once DDS45-LB Joined LoRaWAN network, it will send the MAC command (DeviceTimeReq) and the server will reply with (DeviceTimeAns) to send the current time toDDS45-LB. IfDDS45-LB fails to get the time from the server,DDS45-LB will use the internal time and wait for next time request (AT+SYNCTDC to set the time request period, default is 10 days).468 +Once SW3L-LB Joined LoRaWAN network, it will send the MAC command (DeviceTimeReq) and the server will reply with (DeviceTimeAns) to send the current time to SW3L-LB. If SW3L-LB fails to get the time from the server, SW3L-LB will use the internal time and wait for next time request (AT+SYNCTDC to set the time request period, default is 10 days). 453 453 454 454 (% style="color:red" %)**Note: LoRaWAN Server need to support LoRaWAN v1.0.3(MAC v1.0.3) or higher to support this MAC command feature, Chirpstack,TTN V3 v3 and loriot support but TTN V3 v2 doesn't support. If server doesn't support this command, it will through away uplink packet with this command, so user will lose the packet with time request for TTN V3 v2 if SYNCMOD=1.** 455 455 ... ... @@ -477,7 +477,7 @@ 477 477 ))) 478 478 479 479 ((( 480 -Uplink Internal =5s,means DDS45-LB will send one packet every 5s. range 5~~255s.496 +Uplink Internal =5s,means SW3L-LB will send one packet every 5s. range 5~~255s. 481 481 ))) 482 482 483 483 ... ... @@ -484,17 +484,17 @@ 484 484 == 2.7 Frequency Plans == 485 485 486 486 487 -The DDS45-LB uses OTAA mode and below frequency plans by default. If user want to use it with different frequency plan, please refer the AT command sets.503 +The SW3L-LB uses OTAA mode and below frequency plans by default. If user want to use it with different frequency plan, please refer the AT command sets. 488 488 489 489 [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20Frequency%20Band/>>http://wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20Frequency%20Band/]] 490 490 491 491 492 -= 3. Configure DDS45-LB =508 += 3. Configure SW3L-LB = 493 493 494 494 == 3.1 Configure Methods == 495 495 496 496 497 - DDS45-LB supports below configure method:513 +SW3L-LB supports below configure method: 498 498 499 499 * AT Command via Bluetooth Connection (**Recommended**): [[BLE Configure Instruction>>http://wiki.dragino.com/xwiki/bin/view/Main/BLE%20Bluetooth%20Remote%20Configure/]]. 500 500 ... ... @@ -502,7 +502,6 @@ 502 502 503 503 * LoRaWAN Downlink. Instruction for different platforms: See [[IoT LoRaWAN Server>>http://wiki.dragino.com/xwiki/bin/view/Main/]] section. 504 504 505 - 506 506 == 3.2 General Commands == 507 507 508 508 ... ... @@ -517,10 +517,10 @@ 517 517 [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/>>http://wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/]] 518 518 519 519 520 -== 3.3 Commands special design for DDS45-LB ==535 +== 3.3 Commands special design for SW3L-LB == 521 521 522 522 523 -These commands only valid for DDS45-LB, as below:538 +These commands only valid for SW3L-LB, as below: 524 524 525 525 526 526 === 3.3.1 Set Transmit Interval Time === ... ... @@ -562,140 +562,262 @@ 562 562 Example 1: Downlink Payload: 0100001E ~/~/ Set Transmit Interval (TDC) = 30 seconds 563 563 ))) 564 564 * ((( 565 -Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds 580 +Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds 566 566 ))) 567 567 583 +=== 3.3.2 Quit AT Command === 568 568 569 -=== 3.3.2 Set Interrupt Mode === 570 570 586 +Feature: Quit AT Command mode, so user needs to input the password again before using AT Commands. 571 571 572 - Feature,SetInterrupt modefor PA8of pin.588 +(% style="color:blue" %)**AT Command: AT+DISAT** 573 573 574 -When AT+INTMOD=0 is set, PA8 is used as a digital input port. 590 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:452px" %) 591 +|=(% style="width: 155px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 198px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 99px;background-color:#D9E2F3;color:#0070C0" %)**Response** 592 +|(% style="width:155px" %)AT+DISAT|(% style="width:198px" %)Quit AT Commands mode|(% style="width:96px" %)OK 575 575 576 -(% style="color:blue" %)** ATCommand:AT+INTMOD**594 +(% style="color:blue" %)**Downlink Command:** 577 577 578 -(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %) 579 -|=(% style="width: 155px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 197px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 158px;background-color:#D9E2F3;color:#0070C0" %)**Response** 580 -|(% style="width:154px" %)AT+INTMOD=?|(% style="width:196px" %)Show current interrupt mode|(% style="width:157px" %)((( 581 -0 582 -OK 583 -the mode is 0 =Disable Interrupt 596 +No downlink command for this feature. 597 + 598 + 599 +=== 3.3.3 Get Device Status === 600 + 601 + 602 +Send a LoRaWAN downlink to ask device send Alarm settings. 603 + 604 +(% style="color:blue" %)**Downlink Payload: **(%%)0x26 01 605 + 606 +Sensor will upload Device Status via FPORT=5. See payload section for detail. 607 + 608 + 609 +=== 3.3.4 Alarm for continuously water flow === 610 + 611 + 612 +((( 613 +This feature is to monitor and send Alarm for continuously water flow. 584 584 ))) 585 -|(% style="width:154px" %)AT+INTMOD=2|(% style="width:196px" %)((( 586 -Set Transmit Interval 587 -0. (Disable Interrupt), 588 -~1. (Trigger by rising and falling edge) 589 -2. (Trigger by falling edge) 590 -3. (Trigger by rising edge) 591 -)))|(% style="width:157px" %)OK 592 592 593 -(% style="color:blue" %)**Downlink Command: 0x06** 616 +((( 617 +Example case is for Toilet water monitoring, if some one push toilet button, the toilet will have water flow. If the toilet button has broken and can't returned to original state, the water flow will keep for hours or days which cause huge waste for water. 618 +))) 594 594 595 -Format: Command Code (0x06) followed by 3 bytes. 620 +((( 621 +To monitor this faulty and send alarm, there are two settings: 622 +))) 596 596 597 -This means that the interrupt mode of the end node is set to 0x000003=3 (rising edge trigger), and the type code is 06. 624 +* ((( 625 +(% style="color:#4f81bd" %)**Stop Duration: Unit: Second** 626 +))) 598 598 599 -* Example 1: Downlink Payload: 06000000 ~/~/ Turn off interrupt mode 628 +((( 629 +Default: 15s, If SW3L-LB didn't see any water flow in 15s, SW3L-LB will consider stop of water flow event. 630 +))) 600 600 601 -* Example 2: Downlink Payload: 06000003 ~/~/ Set the interrupt mode to rising edge trigger 632 +* ((( 633 +(% style="color:#4f81bd" %)**Alarm Timer: Units: Minute; Default 0 minutes (means Alarm disable)** 634 +))) 602 602 636 +((( 637 +**Example:** 3 minutes, if SW3L-LB detect a start of water flow event and didn't detect a stop event within Alarm timer, SW3L-LB will send an Alarm to indicate a water flow abnormal alarm. 638 +))) 603 603 604 -= 4. Battery & Power Consumption = 640 +((( 641 +So for example, If we set stop duration=15s and Alarm Timer=3minutes. If the toilet water flow continuously for more than 3 minutes, Sensor will send an alarm (in Confirmed MODE) to platform. 642 +))) 605 605 644 +((( 645 +(% style="color:red" %)**Note:** **After this alarm is send, sensor will consider a stop of water flow and count for another new event. So if water flow waste last for 1 hour, Sensor will keep sending alarm every 3 minutes.** 646 +))) 606 606 607 -DDS45-LB use ER26500 + SPC1520 battery pack. See below link for detail information about the battery info and how to replace. 648 +((( 649 +(% style="color:#4f81bd" %)**AT Command**(%%) to configure: 650 +))) 608 608 609 -[[**Battery Info & Power Consumption Analyze**>>http://wiki.dragino.com/xwiki/bin/view/Main/How%20to%20calculate%20the%20battery%20life%20of%20Dragino%20sensors%3F/]] . 652 +* ((( 653 +AT+PTRIG=15,3 ~-~-> Set Stop duration: 15s, Alarm Timer: 3 minutes. 654 +))) 610 610 656 +* ((( 657 +AT+ PTRIG=15,0 ~-~-> Default Value, disable water waste Alarm. 658 +))) 611 611 612 -= 5. OTA Firmware update = 660 +((( 661 +(% style="color:#4f81bd" %)**Downlink Command**(%%) to configure: 662 +))) 613 613 664 +((( 665 +Command: **0xAA aa bb cc** 666 +))) 614 614 615 -(% class="wikigeneratedid" %) 616 -User can change firmware DDS45-LB to: 668 +((( 669 +AA: Command Type Code 670 +))) 617 617 618 -* Change Frequency band/ region. 672 +((( 673 +aa: Stop duration 674 +))) 619 619 620 -* Update with new features. 676 +((( 677 +bb cc: Alarm Timer 678 +))) 621 621 622 -* Fix bugs. 680 +((( 681 +If user send 0xAA 0F 00 03: equal to AT+PTRIG=15,3 682 +))) 623 623 624 -Firmware and changelog can be downloaded from : **[[Firmware download link>>url:https://www.dropbox.com/sh/a5ue0nfrzqy9nz6/AABbvlATosDJKDwBmbirVbMYa?dl=0]]** 625 625 626 - MethodstoUpdate Firmware:685 +=== 3.3.5 Clear Flash Record === 627 627 628 -* (Recommanded way) OTA firmware update via wireless: [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/Firmware%20OTA%20Update%20for%20Sensors/>>url:http://wiki.dragino.com/xwiki/bin/view/Main/Firmware%20OTA%20Update%20for%20Sensors/]] 629 629 630 - * Updatethrough UART TTL interface: **[[Instruction>>url:http://wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H1.LoRaSTv4baseHardware]]**.688 +Feature: Clear flash storage for data log feature. 631 631 690 +(% style="color:blue" %)**AT Command: AT+CLRDTA** 632 632 633 -= 6. FAQ = 692 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:500px" %) 693 +|=(% style="width: 157px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 169px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 174px;background-color:#D9E2F3;color:#0070C0" %)**Response** 694 +|(% style="width:157px" %)AT+CLRDTA|(% style="width:169px" %)Clear flash storage for data log feature.|Clear all stored sensor data… OK 634 634 635 -== 6.1 What is the frequency plan for DDS45-LB? == 696 +((( 697 +(% style="color:blue" %)**Downlink Command:** 698 +))) 636 636 700 +((( 701 +* **Example**: 0xA301 ~/~/ Same as AT+CLRDTA 702 +))) 637 637 638 -DDS45-LB use the same frequency as other Dragino products. User can see the detail from this link: [[Introduction>>doc:Main.End Device Frequency Band.WebHome||anchor="H1.Introduction"]] 639 639 640 640 641 -== 6.2CanI useDDS45-LB incondensationenvironment?==706 +=== 3.3.6 Set the calculate flag === 642 642 643 643 644 - DDS45-LB is not suitableto be used in condensation environment.CondensationontheDDS45-LB probe willffectthereading and alwaysgot 0.709 +Feature: Set the calculate flag 645 645 711 +(% style="color:blue" %)**AT Command: AT+CALCFLAG** 646 646 647 -= 7. Trouble Shooting = 713 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:461px" %) 714 +|=(% style="width: 158px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 193px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 110px;background-color:#D9E2F3;color:#0070C0" %)**Response** 715 +|(% style="width:158px" %)AT+CALCFLAG =1|(% style="width:192px" %)Set the calculate flag to 1.|(% style="width:109px" %)OK 716 +|(% style="width:158px" %)AT+CALCFLAG =2|(% style="width:192px" %)Set the calculate flag to 2.|(% style="width:109px" %)OK 648 648 649 - ==7.1 WhyIcan'tjoinTTN V3inUS915 / AU915 bands? ==718 +(% style="color:blue" %)**Downlink Command:** 650 650 720 +* **Example**: 0XA501 ~/~/ Same as AT+CALCFLAG =1 651 651 652 - Itisdueochannel mapping. Please see below link: [[Frequencyband>>doc:Main.LoRaWAN Communication Debug.WebHome||anchor="H2.NoticeofUS9152FCN4702FAU915Frequencyband"]]722 +=== 3.3.7 Set count number === 653 653 654 654 655 - ==7.2 AT Command inputdoesn'twork ==725 +Feature: Manually set the count number 656 656 727 +(% style="color:blue" %)**AT Command: AT+SETCNT** 657 657 658 -In the case if user can see the console output but can't type input to the device. Please check if you already include the (% style="color:blue" %)**ENTER**(%%) while sending out the command. Some serial tool doesn't send (% style="color:blue" %)**ENTER**(%%) while press the send key, user need to add ENTER in their string. 729 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:479px" %) 730 +|=(% style="width: 160px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 223px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 96px;background-color:#D9E2F3;color:#0070C0" %)**Response** 731 +|(% style="width:160px" %)AT+ SETCNT =0|(% style="width:221px" %)Set the count number to 0.|(% style="width:95px" %)OK 732 +|(% style="width:160px" %)AT+ SETCNT =100|(% style="width:221px" %)Set the count number to 100.|(% style="width:95px" %)OK 659 659 734 +(% style="color:blue" %)**Downlink Command:** 660 660 661 - ==7.3Whydoesthesensorreadingshow0or "Nosensor"==736 +* **Example**: 0xA6000001 ~/~/ Same as AT+ SETCNT =1 662 662 738 +* **Example**: 0xA6000064 ~/~/ Same as AT+ SETCNT =100 663 663 664 - ~1.Themeasurementobject is very close to the sensor, but in the blind spot of thesensor.740 +=== 3.3.8 Set Interrupt Mode === 665 665 666 -2. Sensor wiring is disconnected 667 667 668 - 3.Notusingthecorrectdecoder743 +Feature, Set Interrupt mode for PA8 of pin. 669 669 745 +When AT+INTMOD=0 is set, PA8 is used as a digital input port. 670 670 671 - ==7.4 Abnormal readingsThe gap between multiplereadings is toolargeorthe gapbetween the readings and the actualvalueistoo large==747 +(% style="color:blue" %)**AT Command: AT+INTMOD** 672 672 749 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %) 750 +|=(% style="width: 155px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 197px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 158px;background-color:#D9E2F3;color:#0070C0" %)**Response** 751 +|(% style="width:154px" %)AT+INTMOD=?|(% style="width:196px" %)Show current interrupt mode|(% style="width:157px" %)((( 752 +0 753 +OK 754 +the mode is 0 =Disable Interrupt 755 +))) 756 +|(% style="width:154px" %)AT+INTMOD=2|(% style="width:196px" %)((( 757 +Set Transmit Interval 758 +0. (Disable Interrupt), 759 +~1. (Trigger by rising and falling edge) 760 +2. (Trigger by falling edge) 761 +3. (Trigger by rising edge) 762 +)))|(% style="width:157px" %)OK 673 673 674 - 1)Please check ifthere is somethingon the probeaffectingitsmeasurement (condensedwater, volatile oil, etc.)764 +(% style="color:blue" %)**Downlink Command: 0x06** 675 675 676 - 2) Does it change withtemperature,temperaturewillaffectitsmeasurement766 +Format: Command Code (0x06) followed by 3 bytes. 677 677 678 - 3)If abnormaldataoccurs,youcanturnonDEBUG mode,PleaseusedownlinkorATCOMMANtoenterDEBUG mode.768 +This means that the interrupt mode of the end node is set to 0x000003=3 (rising edge trigger), and the type code is 06. 679 679 680 - downlinkcommand:(%style="color:blue"%)**F101**(%%),ATcommand:(% style="color:blue"%)**AT+DDEBUG=1**770 +* Example 1: Downlink Payload: 06000000 ~/~/ Turn off interrupt mode 681 681 682 - 4)Afterenteringthe debug mode,itwillsend20piecesofdataata time,andyoucan senditsuplinktous foranalysis772 +* Example 2: Downlink Payload: 06000003 ~/~/ Set the interrupt mode to rising edge trigger 683 683 684 - [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDDS75%20-%20LoRaWAN%20Distance%20Detection%20Sensor%20User%20Manual/WebHome/image-20230113135125-2.png?width=1057&height=136&rev=1.1||alt="image-20230113135125-2.png"]]774 +=== 3.3.9 Set work mode === 685 685 686 686 687 - Its original payload will belonger than otherdata. Eventhoughit isbeing parsed, itcan be seenthatit is abnormaldata.777 +Feature: Manually set the work mode 688 688 689 -Please send the data to us for check. 690 690 780 +(% style="color:blue" %)**AT Command: AT+MOD** 691 691 692 -= 8. Order Info = 782 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:463px" %) 783 +|=(% style="width: 162px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 193px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 108px;background-color:#D9E2F3;color:#0070C0" %)**Response** 784 +|(% style="width:162px" %)AT+MOD=0|(% style="width:191px" %)Set the work mode to 0.|(% style="width:106px" %)OK 785 +|(% style="width:162px" %)AT+MOD=1|(% style="width:191px" %)Set the work mode to 1|(% style="width:106px" %)OK 693 693 787 +(% style="color:blue" %)**Downlink Command:** 694 694 695 - PartNumber: (% style="color:blue"%)**DDS45-LB-XXX**789 +* **Example: **0x0A00 ~/~/ Same as AT+MOD=0 696 696 697 - (%style="color:red" %)**XXX**(%%):**Thedefaultfrequencyband**791 +* **Example:** 0x0A01 ~/~/ Same as AT+MOD=1 698 698 793 += 4. Battery & Power Consumption = 794 + 795 + 796 +SW3L-LB use ER26500 + SPC1520 battery pack. See below link for detail information about the battery info and how to replace. 797 + 798 +[[**Battery Info & Power Consumption Analyze**>>http://wiki.dragino.com/xwiki/bin/view/Main/How%20to%20calculate%20the%20battery%20life%20of%20Dragino%20sensors%3F/]] . 799 + 800 + 801 += 5. OTA Firmware update = 802 + 803 + 804 +(% class="wikigeneratedid" %) 805 +User can change firmware SW3L-LB to: 806 + 807 +* Change Frequency band/ region. 808 + 809 +* Update with new features. 810 + 811 +* Fix bugs. 812 + 813 +Firmware and changelog can be downloaded from : **[[Firmware download link>>url:https://www.dropbox.com/sh/kwqv57tp6pejias/AAAopYMATh1GM6fZ-VRCLrpDa?dl=0]]** 814 + 815 +Methods to Update Firmware: 816 + 817 +* (Recommanded way) OTA firmware update via wireless: [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/Firmware%20OTA%20Update%20for%20Sensors/>>url:http://wiki.dragino.com/xwiki/bin/view/Main/Firmware%20OTA%20Update%20for%20Sensors/]] 818 + 819 +* Update through UART TTL interface. **[[Instruction>>url:http://wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H1.LoRaSTv4baseHardware]]**. 820 + 821 += 6. FAQ = 822 + 823 +== 6.1 AT Commands input doesn't work == 824 + 825 + 826 +In the case if user can see the console output but can't type input to the device. Please check if you already include the (% style="color:green" %)**ENTER**(%%) while sending out the command. Some serial tool doesn't send (% style="color:green" %)**ENTER**(%%) while press the send key, user need to add ENTER in their string. 827 + 828 + 829 += 7. Order Info = 830 + 831 + 832 +Part Number: (% style="color:blue" %)**SW3L-LB-XXX-YYY** 833 + 834 +(% style="color:red" %)**XXX**(%%): The default frequency band 835 + 699 699 * (% style="color:red" %)**AS923**(%%): LoRaWAN AS923 band 700 700 701 701 * (% style="color:red" %)**AU915**(%%): LoRaWAN AU915 band ... ... @@ -712,13 +712,43 @@ 712 712 713 713 * (% style="color:red" %)**CN470**(%%): LoRaWAN CN470 band 714 714 852 +((( 853 +(% style="color:blue" %)**YYY**(%%): Flow Sensor Model: 854 +))) 715 715 716 -= 9. Packing Info = 856 +((( 857 + **004:** DW-004 Flow Sensor: diameter: G1/2” / DN15. 450 pulse = 1 L 858 +))) 717 717 860 +((( 861 + **006:** DW-006 Flow Sensor: diameter: G3/4” / DN20. 390 pulse = 1 L 862 +))) 718 718 864 +((( 865 + **010:** DW-010 Flow Sensor: diameter: G 1” / DN25. 64 pulse = 1 L 866 +))) 867 + 868 +* ((( 869 +calculate flag=0: for SW3L-004 Flow Sensor: 450 pulse = 1 L 870 +))) 871 + 872 +* ((( 873 +calculate flag=1: for SW3L-006 Flow Sensor: 390 pulse = 1 L 874 +))) 875 + 876 +* ((( 877 +calculate flag=2: for SW3L-010 Flow Sensor: 64 pulse = 1 L 878 + 879 + 880 + 881 +))) 882 + 883 += 8. Packing Info = 884 + 885 + 719 719 (% style="color:#037691" %)**Package Includes**: 720 720 721 -* DDS45-LB LoRaWANDistance DetectionSensorx 1888 +* SW3L-LB LoRaWAN Flow Sensor 722 722 723 723 (% style="color:#037691" %)**Dimension and weight**: 724 724 ... ... @@ -730,10 +730,9 @@ 730 730 731 731 * Weight / pcs : g 732 732 900 += 9. Support = 733 733 734 -= 10. Support = 735 735 736 - 737 737 * Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule. 738 738 739 739 * Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[Support@dragino.cc>>mailto:Support@dragino.cc]].
- image-20230613100900-1.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -184.0 KB - Content
- image-20230613102426-2.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -89.3 KB - Content
- image-20230613102459-3.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -89.3 KB - Content