Summary

Details

Page properties
Title
... ... @@ -1,1 +1,1 @@
1 -DDS45-LB -- LoRaWAN Distance Detection Sensor User Manual
1 +DDS75-LB -- LoRaWAN Distance Detection Sensor User Manual
Content
... ... @@ -22,13 +22,13 @@
22 22  
23 23  It detects the distance(% style="color:blue" %)**  between the measured object and the sensor**(%%), and uploads the value via wireless to LoRaWAN IoT Server.
24 24  
25 -The LoRa wireless technology used in DDS75-LB allows device to send data and reach extremely long ranges at low data-rates. It provides ultra-long range spread spectrum communication and high interference immunity whilst minimizing current consumption.
25 +The LoRa wireless technology used in SW3L-LB allows device to send data and reach extremely long ranges at low data-rates. It provides ultra-long range spread spectrum communication and high interference immunity whilst minimizing current consumption.
26 26  
27 -DDS75-LB (% style="color:blue" %)**supports BLE configure**(%%) and (% style="color:blue" %)**wireless OTA update**(%%) which make user easy to use.
27 +SW3L-LB (% style="color:blue" %)**supports BLE configure**(%%) and (% style="color:blue" %)**wireless OTA update**(%%) which make user easy to use.
28 28  
29 -DDS75-LB is powered by (% style="color:blue" %)**8500mAh Li-SOCI2 battery**(%%), it is designed for long term use up to 5 years.
29 +SW3L-LB is powered by (% style="color:blue" %)**8500mAh Li-SOCI2 battery**(%%), it is designed for long term use up to 5 years.
30 30  
31 -Each DDS75-LB is pre-load with a set of unique keys for LoRaWAN registrations, register these keys to local LoRaWAN server and it will auto connect after power on.
31 +Each SW3L-LB is pre-load with a set of unique keys for LoRaWAN registrations, register these keys to local LoRaWAN server and it will auto connect after power on.
32 32  
33 33  [[image:image-20230612170943-2.png||height="525" width="912"]]
34 34  
... ... @@ -50,10 +50,36 @@
50 50  * IP66 Waterproof Enclosure
51 51  * 8500mAh Battery for long term use
52 52  
53 -
54 54  == 1.3 Specification ==
55 55  
56 56  
56 +(% style="color:#037691" %)**Rated environmental conditions:**
57 +
58 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:500px" %)
59 +|(% style="background-color:#d9e2f3; color:#0070c0; width:163px" %)**Item**|(% style="background-color:#d9e2f3; color:#0070c0; width:90px" %)(((
60 +**Minimum value**
61 +)))|(% style="background-color:#d9e2f3; color:#0070c0; width:70px" %)(((
62 +**Typical value**
63 +)))|(% style="background-color:#d9e2f3; color:#0070c0; width:87px" %)(((
64 +**Maximum value**
65 +)))|(% style="background-color:#d9e2f3; color:#0070c0; width:40px" %)**Unit**|(% style="background-color:#d9e2f3; color:#0070c0; width:50px" %)**Remarks**
66 +|(% style="width:174px" %)Storage temperature|(% style="width:86px" %)-25|(% style="width:66px" %)25|(% style="width:90px" %)80|(% style="width:48px" %)℃|(% style="width:203px" %)
67 +|(% style="width:174px" %)Storage humidity|(% style="width:86px" %) |(% style="width:66px" %)65%|(% style="width:90px" %)90%|(% style="width:48px" %)RH|(% style="width:203px" %)(1)
68 +|(% style="width:174px" %)Operating temperature|(% style="width:86px" %)-15|(% style="width:66px" %)25|(% style="width:90px" %)60|(% style="width:48px" %)℃|(% style="width:203px" %)
69 +|(% style="width:174px" %)Working humidity|(% style="width:86px" %)(((
70 +
71 +
72 +
73 +)))|(% style="width:66px" %)65%|(% style="width:90px" %)80%|(% style="width:48px" %)RH|(% style="width:203px" %)(1)
74 +
75 +(((
76 +**Remarks: (1) a. When the ambient temperature is 0-39 ℃, the maximum humidity is 90% (non-condensing);       **
77 +
78 +**~ b. When the ambient temperature is 40-50 ℃, the highest humidity is the highest humidity in the natural world at the current temperature (no condensation)**
79 +
80 +
81 +)))
82 +
57 57  (% style="color:#037691" %)**Common DC Characteristics:**
58 58  
59 59  * Supply Voltage: built in 8500mAh Li-SOCI2 battery , 2.5v ~~ 3.6v
... ... @@ -80,48 +80,20 @@
80 80  * LoRa Transmit Mode: 125mA @ 20dBm, 82mA @ 14dBm
81 81  
82 82  
83 -== 1.4 Rated environmental conditions ==
109 +== 1.4 Effective measurement range Reference beam pattern ==
84 84  
85 85  
86 -(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:500px" %)
87 -|(% style="background-color:#d9e2f3; color:#0070c0; width:163px" %)**Item**|(% style="background-color:#d9e2f3; color:#0070c0; width:90px" %)(((
88 -**Minimum value**
89 -)))|(% style="background-color:#d9e2f3; color:#0070c0; width:70px" %)(((
90 -**Typical value**
91 -)))|(% style="background-color:#d9e2f3; color:#0070c0; width:87px" %)(((
92 -**Maximum value**
93 -)))|(% style="background-color:#d9e2f3; color:#0070c0; width:40px" %)**Unit**|(% style="background-color:#d9e2f3; color:#0070c0; width:50px" %)**Remarks**
94 -|(% style="width:174px" %)Storage temperature|(% style="width:86px" %)-25|(% style="width:66px" %)25|(% style="width:90px" %)80|(% style="width:48px" %)℃|(% style="width:203px" %)
95 -|(% style="width:174px" %)Storage humidity|(% style="width:86px" %) |(% style="width:66px" %)65%|(% style="width:90px" %)90%|(% style="width:48px" %)RH|(% style="width:203px" %)(1)
96 -|(% style="width:174px" %)Operating temperature|(% style="width:86px" %)-15|(% style="width:66px" %)25|(% style="width:90px" %)60|(% style="width:48px" %)℃|(% style="width:203px" %)
97 -|(% style="width:174px" %)Working humidity|(% style="width:86px" %)(((
98 -
112 +**~1. The tested object is a white cylindrical tube made of PVC, with a height of 100cm and a diameter of 7.5cm.**
99 99  
100 -
101 -)))|(% style="width:66px" %)65%|(% style="width:90px" %)80%|(% style="width:48px" %)RH|(% style="width:203px" %)(1)
102 -
103 -(((
104 -(% style="color:red" %)**Remarks: (1) a. When the ambient temperature is 0-39 ℃, the maximum humidity is 90% (non-condensing);       **
105 -
106 -(% style="color:red" %)** b. When the ambient temperature is 40-50 ℃, the highest humidity is the highest humidity in the natural world at the current temperature (no condensation)**
107 -
108 -
109 -)))
110 -
111 -== 1.5 Effective measurement range Reference beam pattern ==
112 -
113 -
114 -(% style="color:blue" %)**1. The tested object is a white cylindrical tube made of PVC, with a height of 100cm and a diameter of 7.5cm.**
115 -
116 116  [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDDS75%20-%20LoRaWAN%20Distance%20Detection%20Sensor%20User%20Manual/WebHome/1654852253176-749.png?rev=1.1||alt="1654852253176-749.png"]]
117 117  
118 118  
119 -(% style="color:blue" %)**2. The object to be tested is a "corrugated cardboard box" perpendicular to the central axis of 0 °, and the length * width is 60cm * 50cm.**
117 +**2. The object to be tested is a "corrugated cardboard box" perpendicular to the central axis of 0 °, and the length * width is 60cm * 50cm.**
120 120  
121 121  [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDDS75%20-%20LoRaWAN%20Distance%20Detection%20Sensor%20User%20Manual/WebHome/1654852175653-550.png?rev=1.1||alt="1654852175653-550.png"]]
122 122  
123 123  
124 -== 1.6 Applications ==
122 +== 1.5 Applications ==
125 125  
126 126  
127 127  * Horizontal distance measurement
... ... @@ -134,16 +134,15 @@
134 134  * Sewer
135 135  * Bottom water level monitoring
136 136  
135 +== 1.6 Sleep mode and working mode ==
137 137  
138 -== 1.7 Sleep mode and working mode ==
139 139  
140 -
141 141  (% style="color:blue" %)**Deep Sleep Mode: **(%%)Sensor doesn't have any LoRaWAN activate. This mode is used for storage and shipping to save battery life.
142 142  
143 143  (% style="color:blue" %)**Working Mode:** (%%)In this mode, Sensor will work as LoRaWAN Sensor to Join LoRaWAN network and send out sensor data to server. Between each sampling/tx/rx periodically, sensor will be in IDLE mode), in IDLE mode, sensor has the same power consumption as Deep Sleep mode.
144 144  
145 145  
146 -== 1.8 Button & LEDs ==
143 +== 1.7 Button & LEDs ==
147 147  
148 148  
149 149  [[image:Main.User Manual for LoRaWAN End Nodes.D20-LBD22-LBD23-LB_LoRaWAN_Temperature_Sensor_User_Manual.WebHome@1675071855856-879.png]]
... ... @@ -162,10 +162,9 @@
162 162  )))
163 163  |(% style="width:167px" %)Fast press ACT 5 times.|(% style="width:117px" %)Deactivate Device|(% style="width:225px" %)(% style="color:red" %)**Red led**(%%) will solid on for 5 seconds. Means device is in Deep Sleep Mode.
164 164  
162 +== 1.8 BLE connection ==
165 165  
166 -== 1.9 BLE connection ==
167 167  
168 -
169 169  DDS75-LB support BLE remote configure.
170 170  
171 171  
... ... @@ -178,14 +178,16 @@
178 178  If there is no activity connection on BLE in 60 seconds, sensor will shut down BLE module to enter low power mode.
179 179  
180 180  
181 -== 1.10 Pin Definitions ==
177 +== 1.9 Pin Definitions ==
182 182  
183 183  [[image:image-20230523174230-1.png]]
184 184  
185 185  
186 -== 1.11 Mechanical ==
182 +== ==
187 187  
184 +== 2.10 Mechanical ==
188 188  
186 +
189 189  [[image:Main.User Manual for LoRaWAN End Nodes.D20-LBD22-LBD23-LB_LoRaWAN_Temperature_Sensor_User_Manual.WebHome@1675143884058-338.png]]
190 190  
191 191  
... ... @@ -195,24 +195,12 @@
195 195  [[image:Main.User Manual for LoRaWAN End Nodes.D20-LBD22-LBD23-LB_LoRaWAN_Temperature_Sensor_User_Manual.WebHome@1675143909447-639.png]]
196 196  
197 197  
198 -(% style="color:blue" %)**Probe Mechanical:**
199 -
200 -
201 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDDS75%20-%20LoRaWAN%20Distance%20Detection%20Sensor%20User%20Manual/WebHome/image-20220610172003-1.png?rev=1.1||alt="image-20220610172003-1.png"]]
202 -
203 -
204 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDDS75%20-%20LoRaWAN%20Distance%20Detection%20Sensor%20User%20Manual/WebHome/image-20220610172003-2.png?rev=1.1||alt="image-20220610172003-2.png"]]
205 -
206 -
207 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDDS75%20-%20LoRaWAN%20Distance%20Detection%20Sensor%20User%20Manual/WebHome/image-20220610172003-2.png?rev=1.1||alt="image-20220610172003-2.png"]]
208 -
209 -
210 210  = 2. Configure DDS75-LB to connect to LoRaWAN network =
211 211  
212 212  == 2.1 How it works ==
213 213  
214 214  
215 -The DDS75-LB is configured as (% style="color:#037691" %)**LoRaWAN OTAA Class A**(%%) mode by default. It has OTAA keys to join LoRaWAN network. To connect a local LoRaWAN network, you need to input the OTAA keys in the LoRaWAN IoT server and press the button to activate the DDS75-LB. It will automatically join the network via OTAA and start to send the sensor value. The default uplink interval is 20 minutes.
201 +The SW3L-LB is configured as (% style="color:#037691" %)**LoRaWAN OTAA Class A**(%%) mode by default. It has OTAA keys to join LoRaWAN network. To connect a local LoRaWAN network, you need to input the OTAA keys in the LoRaWAN IoT server and press the button to activate the SW3L-LB. It will automatically join the network via OTAA and start to send the sensor value. The default uplink interval is 20 minutes.
216 216  
217 217  (% style="display:none" %) (%%)
218 218  
... ... @@ -226,9 +226,9 @@
226 226  [[image:image-20230612171032-3.png||height="492" width="855"]](% style="display:none" %)
227 227  
228 228  
229 -(% style="color:blue" %)**Step 1:**(%%) Create a device in TTN with the OTAA keys from DDS75-LB.
215 +(% style="color:blue" %)**Step 1:**(%%) Create a device in TTN with the OTAA keys from SW3L-LB.
230 230  
231 -Each DDS75-LB is shipped with a sticker with the default device EUI as below:
217 +Each SW3L-LB is shipped with a sticker with the default device EUI as below:
232 232  
233 233  [[image:image-20230426084152-1.png||alt="图片-20230426084152-1.png" height="233" width="502"]]
234 234  
... ... @@ -257,10 +257,10 @@
257 257  [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LSN50v2-S31-S31B%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20User%20Manual/WebHome/image-20220611161308-6.png?width=744&height=485&rev=1.1||alt="图片-20220611161308-6.png"]]
258 258  
259 259  
260 -(% style="color:blue" %)**Step 2:**(%%) Activate on DDS75-LB
246 +(% style="color:blue" %)**Step 2:**(%%) Activate on SW3L-LB
261 261  
262 262  
263 -Press the button for 5 seconds to activate the DDS75-LB.
249 +Press the button for 5 seconds to activate the SW3L-LB.
264 264  
265 265  (% style="color:green" %)**Green led**(%%) will fast blink 5 times, device will enter (% style="color:blue" %)**OTA mode**(%%) for 3 seconds. And then start to JOIN LoRaWAN network. (% style="color:green" %)**Green led**(%%) will solidly turn on for 5 seconds after joined in network.
266 266  
... ... @@ -267,167 +267,355 @@
267 267  After join success, it will start to upload messages to TTN and you can see the messages in the panel.
268 268  
269 269  
270 -== 2.3  ​Uplink Payload ==
256 +== 2.3 ​Uplink Payload ==
271 271  
258 +=== 2.3.1 Device Status, FPORT~=5 ===
272 272  
273 -(((
274 -DDS75-LB will uplink payload via LoRaWAN with below payload format: 
275 -)))
276 276  
277 -(((
278 -Uplink payload includes in total 8 bytes.
279 -)))
261 +Include device configure status. Once SW3L-LB Joined the network, it will uplink this message to the server. After that, SW3L-LB will uplink Device Status every 12 hours.
280 280  
281 -(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:510px" %)
282 -|=(% style="width: 62.5px;background-color:#D9E2F3;color:#0070C0" %)(((
283 -**Size(bytes)**
284 -)))|=(% style="width: 62.5px;background-color:#D9E2F3;color:#0070C0" %)**2**|=(% style="background-color:#D9E2F3;color:#0070C0" %)**2**|=(% style="background-color:#D9E2F3;color:#0070C0" %)1|=(% style="background-color:#D9E2F3;color:#0070C0" %)2|=(% style="background-color:#D9E2F3;color:#0070C0" %)**1**
285 -|(% style="width:62.5px" %)**Value**|(% style="width:62.5px" %)[[BAT>>||anchor="H2.3.1A0BatteryInfo"]]|(((
286 -[[Distance>>||anchor="H2.3.2A0Distance"]]
287 -(unit: mm)
288 -)))|[[Digital Interrupt (Optional)>>||anchor="H2.3.3A0InterruptPin"]]|(((
289 -[[Temperature (Optional )>>||anchor="H2.3.4A0DS18B20Temperaturesensor"]]
290 -)))|[[Sensor Flag>>||anchor="H2.3.5A0SensorFlag"]]
263 +Users can use the downlink command(**0x26 01**) to ask SW3L-LB to send device configure detail, include device configure status. SW3L-LB will uplink a payload via FPort=5 to server.
291 291  
292 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDDS75%20-%20LoRaWAN%20Distance%20Detection%20Sensor%20User%20Manual/WebHome/1654850511545-399.png?rev=1.1||alt="1654850511545-399.png"]]
265 +The Payload format is as below.
293 293  
294 294  
295 -=== 2.3.1  Battery Info ===
268 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %)
269 +|(% colspan="6" style="background-color:#d9e2f3; color:#0070c0" %)**Device Status (FPORT=5)**
270 +|(% style="width:103px" %)**Size (bytes)**|(% style="width:72px" %)**1**|**2**|(% style="width:91px" %)**1**|(% style="width:86px" %)**1**|(% style="width:44px" %)**2**
271 +|(% style="width:103px" %)**Value**|(% style="width:72px" %)Sensor Model|Firmware Version|(% style="width:91px" %)Frequency Band|(% style="width:86px" %)Sub-band|(% style="width:44px" %)BAT
296 296  
273 +Example parse in TTNv3
297 297  
298 -Check the battery voltage for DDS75-LB.
275 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/SW3L%20LoRaWAN%20Outdoor%20Flow%20Sensor/WebHome/1652925144491-755.png?width=732&height=139&rev=1.1||alt="1652925144491-755.png"]]
299 299  
277 +
278 +(% style="color:#037691" %)**Sensor Model**(%%): For SW3L-LB, this value is 0x11
279 +
280 +(% style="color:#037691" %)**Firmware Version**(%%): 0x0100, Means: v1.0.0 version
281 +
282 +(% style="color:#037691" %)**Frequency Band**:
283 +
284 +*0x01: EU868
285 +
286 +*0x02: US915
287 +
288 +*0x03: IN865
289 +
290 +*0x04: AU915
291 +
292 +*0x05: KZ865
293 +
294 +*0x06: RU864
295 +
296 +*0x07: AS923
297 +
298 +*0x08: AS923-1
299 +
300 +*0x09: AS923-2
301 +
302 +*0x0a: AS923-3
303 +
304 +*0x0b: CN470
305 +
306 +*0x0c: EU433
307 +
308 +*0x0d: KR920
309 +
310 +*0x0e: MA869
311 +
312 +
313 +(% style="color:#037691" %)**Sub-Band**:
314 +
315 +AU915 and US915:value 0x00 ~~ 0x08
316 +
317 +CN470: value 0x0B ~~ 0x0C
318 +
319 +Other Bands: Always 0x00
320 +
321 +
322 +(% style="color:#037691" %)**Battery Info**:
323 +
324 +Check the battery voltage.
325 +
300 300  Ex1: 0x0B45 = 2885mV
301 301  
302 302  Ex2: 0x0B49 = 2889mV
303 303  
304 304  
305 -=== 2.3.2  Distance ===
331 +=== 2.3.2 Sensor Configuration, FPORT~=4 ===
306 306  
307 307  
334 +SW3L-LB will only send this command after getting the downlink command (0x26 02) from the server.
335 +
336 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:510px" %)
337 +|(% style="background-color:#d9e2f3; color:#0070c0; width:70px" %) **Size(bytes)**|(% style="background-color:#d9e2f3; color:#0070c0; width:105px" %)**3**|(% style="background-color:#d9e2f3; color:#0070c0; width:60px" %)**1**|(% style="background-color:#d9e2f3; color:#0070c0; width:96px" %)**1**|(% style="background-color:#d9e2f3; color:#0070c0; width:105px" %)**2**|(% style="background-color:#d9e2f3; color:#0070c0; width:74px" %)**1**
338 +|**Value**|(% style="width:104px" %)TDC(unit:sec)|(% style="width:43px" %)N/A|(% style="width:91px" %)Stop Timer|(% style="width:100px" %)Alarm Timer|(% style="width:69px" %)Reserve
339 +
340 +* (% style="color:#037691" %)**TDC: (default: 0x0004B0)**
341 +
342 +Uplink interval for the total pulse count, default value is 0x0004B0 which is 1200 seconds = 20 minutes.
343 +
344 +
345 +* (% style="color:#037691" %)**STOP Duration & Alarm Timer**
346 +
347 +Shows the configure value of [[Alarm for continuously water flow>>||anchor="H3.3.4Alarmforcontinuouslywaterflow"]]
348 +
349 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/SW3L%20LoRaWAN%20Outdoor%20Flow%20Sensor/WebHome/image-20220519095747-2.png?width=723&height=113&rev=1.1||alt="image-20220519095747-2.png"]]
350 +
351 +
352 +=== 2.3.3 Water Flow Value, Uplink FPORT~=2 ===
353 +
354 +
308 308  (((
309 -Get the distance. Flat object range 280mm - 7500mm.
356 +SW3L-LB will send this uplink **after** Device Status once join the LoRaWAN network successfully. And SW3L-LB will:
310 310  )))
311 311  
312 312  (((
313 -For example, if the data you get from the register is 0x0B 0x05, the distance between the sensor and the measured object is(% style="color:#4472c4" %)** **
360 +periodically send this uplink every 20 minutes, this interval [[can be changed>>||anchor="H3.3.1SetTransmitIntervalTime"]].
361 +)))
314 314  
315 -(% style="color:#4472c4" %)**0B05(H) = 2821 (D) = 2821 mm.**
363 +(((
364 +Uplink Payload totals 11 bytes.
316 316  )))
317 317  
367 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:510px" %)
368 +|=(% colspan="6" style="width: 510px;background-color:#D9E2F3;color:#0070C0" %)**Water Flow Value,  FPORT=2**
369 +|(% style="width:60px" %)**Size(bytes)**|(% style="width:130px" %)**1**|(% style="width:130px" %)**4**|(% style="width:30px" %)**1**|(% style="width:50px" %)**1**|(% style="width:80px" %)**4**
370 +|(% style="width:110px" %)**Value**|(% style="width:81px" %)Calculate Flag & [[Alarm>>||anchor="H3.3.4Alarmforcontinuouslywaterflow"]]|(% style="width:95px" %)(((
371 +Total pulse Or Last Pulse
372 +)))|(% style="width:55px" %)MOD|(% style="width:115px" %)Reserve(0x01)|(% style="width:129px" %)[[Unix TimeStamp>>||anchor="H2.5.2UnixTimeStamp"]]
318 318  
319 -* If the sensor value is 0x0000, it means system doesn't detect ultrasonic sensor.
320 -* If the sensor value lower than 0x0118 (280mm), the sensor value will be invalid. All value lower than 280mm will be set to 0x0014(20mm) which means the value is invalid.
374 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:470px" %)
375 +|=(% colspan="4" style="width: 470px;background-color:#D9E2F3;color:#0070C0" %)**Status & Alarm field**
376 +|(% style="width:60px" %)**Size(bit)**|(% style="width:80px" %)**6**|(% style="width:310px" %)**1**|(% style="width:20px" %)**1**
377 +|(% style="width:88px" %)**Value**|(% style="width:117px" %)Calculate Flag|(% style="width:221px" %)Alarm: 0: No Alarm; 1: Alarm|(% style="width:64px" %)N/A
321 321  
379 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/SW3L%20LoRaWAN%20Outdoor%20Flow%20Sensor/WebHome/image-20220519095946-3.png?width=736&height=284&rev=1.1||alt="image-20220519095946-3.png"]]
322 322  
323 -=== 2.3.3  Interrupt Pin ===
324 324  
382 +* (((
383 +(% style="color:#037691" %)**Calculate Flag**
384 +)))
325 325  
326 -This data field shows if this packet is generated by interrupt or not. [[Click here>>||anchor="H3.3.2SetInterruptMode"]] for the hardware and software set up.
386 +(((
387 +The calculate flag is a user defined field, IoT server can use this flag to handle different meters with different pulse factors. For example, if there are 100 Flow Sensors, meters 1 ~~50 are 1 liter/pulse and meters 51 ~~ 100 has 1.5 liter/pulse.
388 +)))
327 327  
328 -**Example:**
390 +(((
391 +**Example: in the default payload:**
392 +)))
329 329  
330 -0x00: Normal uplink packet.
394 +* (((
395 +calculate flag=0: for SW3L-004 Flow Sensor: 450 pulse = 1 L
396 +)))
397 +* (((
398 +calculate flag=1: for SW3L-006 Flow Sensor: 390 pulse = 1 L
399 +)))
400 +* (((
401 +calculate flag=2: for SW3L-010 Flow Sensor: 64 pulse = 1 L
402 +)))
331 331  
332 -0x01: Interrupt Uplink Packet.
404 +(((
405 +Default value: 0. 
406 +)))
333 333  
408 +(((
409 +Range (6 bits): (b)000000 ~~ (b) 111111
334 334  
335 -=== 2.3.4  DS18B20 Temperature sensor ===
411 +If user use with a meter for example is 0.02L/pulse. To proper decode the correct value in server,
336 336  
413 +1) User can set the Calculate Flag of this sensor to 3.
337 337  
338 -This is optional, user can connect external DS18B20 sensor to the +3.3v, 1-wire and GND pin . and this field will report temperature.
415 +2) In server side, when a sensor data arrive, the decoder will check the value of Calculate Flag, It the value is 3, the total volume = 0.02 x Pulse Count.
416 +)))
339 339  
340 -**Example**:
418 +(((
419 +(% style="color:red" %)**NOTE: User need to set Calculate Flag to proper value before use Flow Sensor. Downlink or AT Command see: **(%%)Refer: [[Set Calculate Flag>>||anchor="H3.3.6Setthecalculateflag"]]
420 +)))
341 341  
342 -If payload is: 0105H:  (0105 & FC00 == 0), temp = 0105H /10 = 26.1 degree
422 +* (((
423 +(% style="color:#037691" %)**Alarm**
424 +)))
343 343  
344 -If payload is: FF3FH :  (FF3F & FC00 == 1) , temp = (FF3FH - 65536)/10 = -19.3 degrees.
426 +(((
427 +See [[Alarm for continuously water flow>>||anchor="H3.3.4Alarmforcontinuouslywaterflow"]]
428 +)))
345 345  
430 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/SW3L%20LoRaWAN%20Outdoor%20Flow%20Sensor/WebHome/image-20220519095946-4.png?width=724&height=65&rev=1.1||alt="image-20220519095946-4.png"]]
346 346  
347 -=== 2.3.5  Sensor Flag ===
348 348  
433 +* (((
434 +(% style="color:#037691" %)**Total pulse**
435 +)))
349 349  
350 350  (((
351 -0x01: Detect Ultrasonic Sensor
438 +Total pulse/counting since factory
352 352  )))
353 353  
354 354  (((
355 -0x00: No Ultrasonic Sensor
442 +Range (4 Bytes) : 0x00000000~~ 0xFFFFFFFF .
356 356  )))
357 357  
445 +* (((
446 +(% style="color:#037691" %)**Last Pulse**
447 +)))
358 358  
359 -=== 2.3.6  Decode payload in The Things Network ===
449 +(((
450 +Total pulse since last FPORT=2 uplink. (Default 20 minutes)
451 +)))
360 360  
453 +(((
454 +Range (4 Bytes) : 0x00000000~~ 0xFFFFFFFF .
455 +)))
361 361  
362 -While using TTN network, you can add the payload format to decode the payload.
457 +* (((
458 +(% style="color:#037691" %)**MOD: Default =0**
459 +)))
363 363  
364 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDDS75%20-%20LoRaWAN%20Distance%20Detection%20Sensor%20User%20Manual/WebHome/1654850829385-439.png?rev=1.1||alt="1654850829385-439.png"]]
461 +(((
462 +MOD=0 ~-~-> Uplink Total Pulse since factory
463 +)))
365 365  
366 -The payload decoder function for TTN V3 is here:
465 +(((
466 +MOD=1 ~-~-> Uplink total pulse since last FPORT=2 uplink.
467 +)))
367 367  
469 +* (((
470 +(% style="color:#037691" %)**Water Flow Value**
471 +)))
472 +
368 368  (((
369 -DDS75-LB TTN V3 Payload Decoder:  [[ttps:~~/~~/github.com/dragino/dragino-end-node-decoder>>https://github.com/dragino/dragino-end-node-decoder]]
474 +**Total Water Flow Volume = (Calculate Flag) x (Total Pulse)=9597/450=21.3L**
370 370  )))
371 371  
477 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/SW3L%20LoRaWAN%20Outdoor%20Flow%20Sensor/WebHome/image-20220519095946-5.png?width=727&height=50&rev=1.1||alt="image-20220519095946-5.png"]]
372 372  
373 -== 2.4  Uplink Interval ==
374 374  
480 +(((
481 +**Total Water Flow for TDC timer = (Calculate Flag) x (Last Pulse)=79/450=0.2L**
482 +)))
375 375  
376 -The DDS75-LB by default uplink the sensor data every 20 minutes. User can change this interval by AT Command or LoRaWAN Downlink Command. See this link: [[Change Uplink Interval>>||anchor="H3.3.1SetTransmitIntervalTime"]]
484 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/SW3L%20LoRaWAN%20Outdoor%20Flow%20Sensor/WebHome/image-20220519095946-6.png?width=733&height=43&rev=1.1||alt="image-20220519095946-6.png"]] ** **
377 377  
378 378  
379 -== 2. ​Show Data in DataCake IoT Server ==
487 +=== 2.3.4 Historical Water Flow Status, FPORT~=3 ===
380 380  
381 381  
382 382  (((
383 -[[DATACAKE>>url:https://datacake.co/]] provides a human friendly interface to show the sensor data, once we have data in TTN, we can use [[DATACAKE>>url:https://datacake.co/]] to connect to TTN and see the data in DATACAKE. Below are the steps:
491 +SW3L-LB stores sensor values and users can retrieve these history values via the [[downlink command>>||anchor="H2.5DatalogFeature"]].
384 384  )))
385 385  
494 +(((
495 +The historical payload includes one or multiplies entries and every entry has the same payload as Real-Time water flow status.
496 +)))
386 386  
498 +* (((
499 +Each data entry is 11 bytes and has the same structure as [[real time water flow status>>||anchor="H2.3.3A0WaterFlowValue2CUplinkFPORT3D2"]], to save airtime and battery, SW3L will send max bytes according to the current DR and Frequency bands.
500 +)))
501 +
387 387  (((
388 -(% style="color:blue" %)**Step 1**(%%)**: Be sure that your device is programmed and properly connected to the network at this time.**
503 +For example, in the US915 band, the max payload for different DR is:
389 389  )))
390 390  
391 391  (((
392 -(% style="color:blue" %)**Step 2**(%%)**: To configure the Application to forward data to DATACAKE you will need to add integration. To add the DATACAKE integration, perform the following steps:**
507 +(% style="color:blue" %)**a) DR0:**(%%) max is 11 bytes so one entry of data
393 393  )))
394 394  
510 +(((
511 +(% style="color:blue" %)**b) DR1:**(%%) max is 53 bytes so devices will upload 4 entries of data (total 44 bytes)
512 +)))
395 395  
396 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDDS75%20-%20LoRaWAN%20Distance%20Detection%20Sensor%20User%20Manual/WebHome/1654592790040-760.png?rev=1.1||alt="1654592790040-760.png"]]
514 +(((
515 +(% style="color:blue" %)**c) DR2:**(%%) total payload includes 11 entries of data
516 +)))
397 397  
518 +(((
519 +(% style="color:blue" %)**d) DR3:**(%%) total payload includes 22 entries of data.
520 +)))
398 398  
399 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDDS75%20-%20LoRaWAN%20Distance%20Detection%20Sensor%20User%20Manual/WebHome/1654592800389-571.png?rev=1.1||alt="1654592800389-571.png"]]
522 +(((
523 +If SW3L-LB doesn't have any data in the polling time. It will uplink 11 bytes of 0
524 +)))
400 400  
526 +(((
527 +(% style="color:#037691" %)**Downlink:**
528 +)))
401 401  
402 -(% style="color:blue" %)**Step 3**(%%)**: Create an account or log in Datacake.**
530 +(((
531 +0x31 62 46 B1 F0 62 46 B3 94 07
532 +)))
403 403  
404 -(% style="color:blue" %)**Step 4**(%%)**: Search the DDS75-LB and add DevEUI.**
534 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/SW3L%20LoRaWAN%20Outdoor%20Flow%20Sensor/WebHome/1652926690850-712.png?width=726&height=115&rev=1.1||alt="1652926690850-712.png"]]
405 405  
406 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDDS75%20-%20LoRaWAN%20Distance%20Detection%20Sensor%20User%20Manual/WebHome/1654851029373-510.png?rev=1.1||alt="1654851029373-510.png"]]
407 407  
537 +(((
538 +(% style="color:#037691" %)**Uplink:**
539 +)))
408 408  
409 -After added, the sensor data arrive TTN V3, it will also arrive and show in Datacake.
541 +(((
542 +00 00 01 00 00 00 00 62 46 B2 26 00 00 01 00 00 00 00 62 46 B2 5D 00 00 01 00 00 00 00 62 46 B2 99 00 00 01 00 00 00 00 62 46 B2 D5 00 00 01 00 00 01 15 62 46 B3 11 00 00 01 00 00 01 1F 62 46 B3 7E
543 +)))
410 410  
411 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDDS75%20-%20LoRaWAN%20Distance%20Detection%20Sensor%20User%20Manual/WebHome/image-20220610165129-11.png?width=1088&height=595&rev=1.1||alt="image-20220610165129-11.png"]]
545 +(((
546 +(% style="color:#037691" %)**Parsed Value:**
547 +)))
412 412  
549 +(((
550 +[Alarm, Calculate Flag, MOD, Total pulse or Last Pulse,** **Water Flow Value, TIME]
551 +)))
413 413  
414 414  
415 -== 2.6 Datalog Feature ==
554 +(((
555 +[FALSE,0,0,0,0.0,2022-04-01 08:04:54],
556 +)))
416 416  
558 +(((
559 +[FALSE,0,0,0,0.0,2022-04-01 08:05:49],
560 +)))
417 417  
418 -Datalog Feature is to ensure IoT Server can get all sampling data from Sensor even if the LoRaWAN network is down. For each sampling, DDS75-LB will store the reading for future retrieving purposes.
562 +(((
563 +[FALSE,0,0,0,0.0,2022-04-01 08:06:49],
564 +)))
419 419  
566 +(((
567 +[FALSE,0,0,0,0.0,2022-04-01 08:07:49],
568 +)))
420 420  
421 -=== 2.6.1 Ways to get datalog via LoRaWAN ===
570 +(((
571 +[FALSE,0,0,277,0.6,2022-04-01 08:08:49],
572 +)))
422 422  
574 +(((
575 +[FALSE,0,0,287,0.6,2022-04-01 08:10:38],
576 +)))
423 423  
424 -Set PNACKMD=1, DDS75-LB will wait for ACK for every uplink, when there is no LoRaWAN network,DDS75-LB will mark these records with non-ack messages and store the sensor data, and it will send all messages (10s interval) after the network recovery.
578 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/SW3L%20LoRaWAN%20Outdoor%20Flow%20Sensor/WebHome/1652926777796-267.png?width=724&height=279&rev=1.1||alt="1652926777796-267.png"]]
425 425  
580 +
581 +== 2.4 Payload Decoder file ==
582 +
583 +
584 +In TTN, use can add a custom payload so it shows friendly reading
585 +
586 +In the page (% style="color:#037691" %)**Applications ~-~-> Payload Formats ~-~-> Custom ~-~-> decoder**(%%) to add the decoder from: [[https:~~/~~/github.com/dragino/dragino-end-node-decoder>>https://github.com/dragino/dragino-end-node-decoder]]
587 +
588 +
589 +== 2.5 Datalog Feature ==
590 +
591 +
592 +Datalog Feature is to ensure IoT Server can get all sampling data from Sensor even if the LoRaWAN network is down. For each sampling, SW3L-LB will store the reading for future retrieving purposes.
593 +
594 +
595 +=== 2.5.1 Ways to get datalog via LoRaWAN ===
596 +
597 +
598 +Set PNACKMD=1, SW3L-LB will wait for ACK for every uplink, when there is no LoRaWAN network,SW3L-LB will mark these records with non-ack messages and store the sensor data, and it will send all messages (10s interval) after the network recovery.
599 +
426 426  * (((
427 -a) DDS75-LB will do an ACK check for data records sending to make sure every data arrive server.
601 +a) SW3L-LB will do an ACK check for data records sending to make sure every data arrive server.
428 428  )))
429 429  * (((
430 -b) DDS75-LB will send data in **CONFIRMED Mode** when PNACKMD=1, but DDS75-LB won't re-transmit the packet if it doesn't get ACK, it will just mark it as a NONE-ACK message. In a future uplink if DDS75-LB gets a ACK, DDS75-LB will consider there is a network connection and resend all NONE-ACK messages.
604 +b) SW3L-LB will send data in **CONFIRMED Mode** when PNACKMD=1, but SW3L-LB won't re-transmit the packet if it doesn't get ACK, it will just mark it as a NONE-ACK message. In a future uplink if SW3L-LB gets a ACK, SW3L-LB will consider there is a network connection and resend all NONE-ACK messages.
431 431  )))
432 432  
433 433  Below is the typical case for the auto-update datalog feature (Set PNACKMD=1)
... ... @@ -435,10 +435,10 @@
435 435  [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/WebHome/image-20220703111700-2.png?width=1119&height=381&rev=1.1||alt="图片-20220703111700-2.png" height="381" width="1119"]]
436 436  
437 437  
438 -=== 2.6.2 Unix TimeStamp ===
612 +=== 2.5.2 Unix TimeStamp ===
439 439  
440 440  
441 -DDS75-LB uses Unix TimeStamp format based on
615 +SW3L-LB uses Unix TimeStamp format based on
442 442  
443 443  [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/WebHome/image-20220523001219-11.png?width=627&height=97&rev=1.1||alt="图片-20220523001219-11.png" height="97" width="627"]]
444 444  
... ... @@ -452,17 +452,17 @@
452 452  So, we can use AT+TIMESTAMP=1611889405 or downlink 3060137afd00 to set the current time 2021 – Jan ~-~- 29 Friday 03:03:25
453 453  
454 454  
455 -=== 2.6.3 Set Device Time ===
629 +=== 2.5.3 Set Device Time ===
456 456  
457 457  
458 458  User need to set (% style="color:blue" %)**SYNCMOD=1**(%%) to enable sync time via MAC command.
459 459  
460 -Once DDS75-LB Joined LoRaWAN network, it will send the MAC command (DeviceTimeReq) and the server will reply with (DeviceTimeAns) to send the current time to DDS75-LB. If DDS75-LB fails to get the time from the server, DDS75-LB will use the internal time and wait for next time request (AT+SYNCTDC to set the time request period, default is 10 days).
634 +Once SW3L-LB Joined LoRaWAN network, it will send the MAC command (DeviceTimeReq) and the server will reply with (DeviceTimeAns) to send the current time to SW3L-LB. If SW3L-LB fails to get the time from the server, SW3L-LB will use the internal time and wait for next time request (AT+SYNCTDC to set the time request period, default is 10 days).
461 461  
462 462  (% style="color:red" %)**Note: LoRaWAN Server need to support LoRaWAN v1.0.3(MAC v1.0.3) or higher to support this MAC command feature, Chirpstack,TTN V3 v3 and loriot support but TTN V3 v2 doesn't support. If server doesn't support this command, it will through away uplink packet with this command, so user will lose the packet with time request for TTN V3 v2 if SYNCMOD=1.**
463 463  
464 464  
465 -=== 2.6.4 Poll sensor value ===
639 +=== 2.5.4 Poll sensor value ===
466 466  
467 467  
468 468  Users can poll sensor values based on timestamps. Below is the downlink command.
... ... @@ -485,24 +485,24 @@
485 485  )))
486 486  
487 487  (((
488 -Uplink Internal =5s,means DDS75-LB will send one packet every 5s. range 5~~255s.
662 +Uplink Internal =5s,means SW3L-LB will send one packet every 5s. range 5~~255s.
489 489  )))
490 490  
491 491  
492 -== 2.7 Frequency Plans ==
666 +== 2.6 Frequency Plans ==
493 493  
494 494  
495 -The DDS75-LB uses OTAA mode and below frequency plans by default. If user want to use it with different frequency plan, please refer the AT command sets.
669 +The SW3L-LB uses OTAA mode and below frequency plans by default. If user want to use it with different frequency plan, please refer the AT command sets.
496 496  
497 497  [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20Frequency%20Band/>>http://wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20Frequency%20Band/]]
498 498  
499 499  
500 -= 3. Configure DDS75-LB =
674 += 3. Configure SW3L-LB =
501 501  
502 502  == 3.1 Configure Methods ==
503 503  
504 504  
505 -DDS75-LB supports below configure method:
679 +SW3L-LB supports below configure method:
506 506  
507 507  * AT Command via Bluetooth Connection (**Recommended**): [[BLE Configure Instruction>>http://wiki.dragino.com/xwiki/bin/view/Main/BLE%20Bluetooth%20Remote%20Configure/]].
508 508  
... ... @@ -510,7 +510,6 @@
510 510  
511 511  * LoRaWAN Downlink.  Instruction for different platforms: See [[IoT LoRaWAN Server>>http://wiki.dragino.com/xwiki/bin/view/Main/]] section.
512 512  
513 -
514 514  == 3.2 General Commands ==
515 515  
516 516  
... ... @@ -525,10 +525,10 @@
525 525  [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/>>http://wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/]]
526 526  
527 527  
528 -== 3.3 Commands special design for DDS75-LB ==
701 +== 3.3 Commands special design for SW3L-LB ==
529 529  
530 530  
531 -These commands only valid for DDS75-LB, as below:
704 +These commands only valid for SW3L-LB, as below:
532 532  
533 533  
534 534  === 3.3.1 Set Transmit Interval Time ===
... ... @@ -571,141 +571,261 @@
571 571  )))
572 572  * (((
573 573  Example 2: Downlink Payload: 0100003C  ~/~/ Set Transmit Interval (TDC) = 60 seconds
747 +)))
574 574  
749 +=== 3.3.2 Quit AT Command ===
575 575  
576 -
751 +
752 +Feature: Quit AT Command mode, so user needs to input the password again before using AT Commands.
753 +
754 +(% style="color:blue" %)**AT Command: AT+DISAT**
755 +
756 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:452px" %)
757 +|=(% style="width: 155px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 198px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 99px;background-color:#D9E2F3;color:#0070C0" %)**Response**
758 +|(% style="width:155px" %)AT+DISAT|(% style="width:198px" %)Quit AT Commands mode|(% style="width:96px" %)OK
759 +
760 +(% style="color:blue" %)**Downlink Command:**
761 +
762 +No downlink command for this feature.
763 +
764 +
765 +=== 3.3.3 Get Device Status ===
766 +
767 +
768 +Send a LoRaWAN downlink to ask device send Alarm settings.
769 +
770 +(% style="color:blue" %)**Downlink Payload:  **(%%)0x26 01
771 +
772 +Sensor will upload Device Status via FPORT=5. See payload section for detail.
773 +
774 +
775 +=== 3.3.4 Alarm for continuously water flow ===
776 +
777 +
778 +(((
779 +This feature is to monitor and send Alarm for continuously water flow.
577 577  )))
578 578  
579 -=== 3.3.2 Set Interrupt Mode ===
782 +(((
783 +Example case is for Toilet water monitoring, if some one push toilet button, the toilet will have water flow. If the toilet button has broken and can't returned to original state, the water flow will keep for hours or days which cause huge waste for water.
784 +)))
580 580  
786 +(((
787 +To monitor this faulty and send alarm, there are two settings:
788 +)))
581 581  
582 -Feature, Set Interrupt mode for PA8 of pin.
790 +* (((
791 +(% style="color:#4f81bd" %)**Stop Duration: Unit: Second**
792 +)))
583 583  
584 -When AT+INTMOD=0 is set, PA8 is used as a digital input port.
794 +(((
795 +Default: 15s, If SW3L-LB didn't see any water flow in 15s, SW3L-LB will consider stop of water flow event.
796 +)))
585 585  
586 -(% style="color:blue" %)**AT Command: AT+INTMOD**
798 +* (((
799 +(% style="color:#4f81bd" %)**Alarm Timer: Units: Minute; Default 0 minutes (means Alarm disable)**
800 +)))
587 587  
588 -(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %)
589 -|=(% style="width: 155px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 197px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 158px;background-color:#D9E2F3;color:#0070C0" %)**Response**
590 -|(% style="width:154px" %)AT+INTMOD=?|(% style="width:196px" %)Show current interrupt mode|(% style="width:157px" %)(((
591 -0
592 -OK
593 -the mode is 0 =Disable Interrupt
802 +(((
803 +**Example:** 3 minutes, if SW3L-LB detect a start of water flow event and didn't detect a stop event within Alarm timer, SW3L-LB will send an Alarm to indicate a water flow abnormal alarm.
594 594  )))
595 -|(% style="width:154px" %)AT+INTMOD=2|(% style="width:196px" %)(((
596 -Set Transmit Interval
597 -0. (Disable Interrupt),
598 -~1. (Trigger by rising and falling edge)
599 -2. (Trigger by falling edge)
600 -3. (Trigger by rising edge)
601 -)))|(% style="width:157px" %)OK
602 602  
603 -(% style="color:blue" %)**Downlink Command: 0x06**
806 +(((
807 +So for example, If we set stop duration=15s and Alarm Timer=3minutes. If the toilet water flow continuously for more than 3 minutes, Sensor will send an alarm (in Confirmed MODE) to platform.
808 +)))
604 604  
605 -Format: Command Code (0x06) followed by 3 bytes.
810 +(((
811 +(% style="color:red" %)**Note:** **After this alarm is send, sensor will consider a stop of water flow and count for another new event. So if water flow waste last for 1 hour, Sensor will keep sending alarm every 3 minutes.**
812 +)))
606 606  
607 -This means that the interrupt mode of the end node is set to 0x000003=3 (rising edge trigger), and the type code is 06.
814 +(((
815 +(% style="color:#4f81bd" %)**AT Command**(%%) to configure:
816 +)))
608 608  
609 -* Example 1: Downlink Payload: 06000000  ~/~/  Turn off interrupt mode
818 +* (((
819 +AT+PTRIG=15,3  ~-~-> Set Stop duration: 15s, Alarm Timer: 3 minutes.
820 +)))
610 610  
611 -* Example 2: Downlink Payload: 06000003  ~/~/  Set the interrupt mode to rising edge trigger
822 +* (((
823 +AT+ PTRIG=15,0  ~-~-> Default Value, disable water waste Alarm.
824 +)))
612 612  
826 +(((
827 +(% style="color:#4f81bd" %)**Downlink Command**(%%) to configure: 
828 +)))
613 613  
614 -= 4. Battery & Power Consumption =
830 +(((
831 +Command: **0xAA aa bb cc**
832 +)))
615 615  
834 +(((
835 +AA: Command Type Code
836 +)))
616 616  
617 -DDS75-LB use ER26500 + SPC1520 battery pack. See below link for detail information about the battery info and how to replace.
838 +(((
839 +aa: Stop duration
840 +)))
618 618  
619 -[[**Battery Info & Power Consumption Analyze**>>http://wiki.dragino.com/xwiki/bin/view/Main/How%20to%20calculate%20the%20battery%20life%20of%20Dragino%20sensors%3F/]] .
842 +(((
843 +bb cc: Alarm Timer
844 +)))
620 620  
846 +(((
847 +If user send 0xAA 0F 00 03: equal to AT+PTRIG=15,3
848 +)))
621 621  
622 -= 5. OTA Firmware update =
623 623  
851 +=== 3.3.5 Clear Flash Record ===
624 624  
625 -(% class="wikigeneratedid" %)
626 -User can change firmware DDS75-LB to:
627 627  
628 -* Change Frequency band/ region.
854 +Feature: Clear flash storage for data log feature.
629 629  
630 -* Update with new features.
856 +(% style="color:blue" %)**AT Command: AT+CLRDTA**
631 631  
632 -* Fix bugs.
858 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:500px" %)
859 +|=(% style="width: 157px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 169px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 174px;background-color:#D9E2F3;color:#0070C0" %)**Response**
860 +|(% style="width:157px" %)AT+CLRDTA|(% style="width:169px" %)Clear flash storage for data log feature.|Clear all stored sensor data… OK
633 633  
634 -Firmware and changelog can be downloaded from : **[[Firmware download link>>url:https://www.dropbox.com/sh/7la95mae0fn03xe/AACtzs-32m22TLb75B-iIr-Qa?dl=0]]**
862 +(((
863 +(% style="color:blue" %)**Downlink Command:**
864 +)))
635 635  
636 -Methods to Update Firmware:
866 +(((
867 +* **Example**: 0xA301  ~/~/  Same as AT+CLRDTA
868 +)))
637 637  
638 -* (Recommanded way) OTA firmware update via wireless:  [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/Firmware%20OTA%20Update%20for%20Sensors/>>url:http://wiki.dragino.com/xwiki/bin/view/Main/Firmware%20OTA%20Update%20for%20Sensors/]]
639 639  
640 -* Update through UART TTL interface: **[[Instruction>>url:http://wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H1.LoRaSTv4baseHardware]]**.
641 641  
872 +=== 3.3.6 Set the calculate flag ===
642 642  
643 -= 6. FAQ =
644 644  
645 -== 6.1  What is the frequency plan for DDS75-LB? ==
875 +Feature: Set the calculate flag
646 646  
877 +(% style="color:blue" %)**AT Command: AT+CALCFLAG**
647 647  
648 -DDS75-LB use the same frequency as other Dragino products. User can see the detail from this link:  [[Introduction>>doc:Main.End Device Frequency Band.WebHome||anchor="H1.Introduction"]]
879 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:461px" %)
880 +|=(% style="width: 158px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 193px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 110px;background-color:#D9E2F3;color:#0070C0" %)**Response**
881 +|(% style="width:158px" %)AT+CALCFLAG =1|(% style="width:192px" %)Set the calculate flag to 1.|(% style="width:109px" %)OK
882 +|(% style="width:158px" %)AT+CALCFLAG =2|(% style="width:192px" %)Set the calculate flag to 2.|(% style="width:109px" %)OK
649 649  
884 +(% style="color:blue" %)**Downlink Command:**
650 650  
651 -== 6.2  Can I use DDS75-LB in condensation environment? ==
886 +* **Example**: 0XA501  ~/~/  Same as AT+CALCFLAG =1
652 652  
888 +=== 3.3.7 Set count number ===
653 653  
654 -DDS75-LB is not suitable to be used in condensation environment. Condensation on the DDS75-LB probe will affect the reading and always got 0.
655 655  
891 +Feature: Manually set the count number
656 656  
657 -= 7.  Trouble Shooting =
893 +(% style="color:blue" %)**AT Command: AT+SETCNT**
658 658  
659 -== 7.1  Why I can't join TTN V3 in US915 / AU915 bands? ==
895 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:479px" %)
896 +|=(% style="width: 160px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 223px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 96px;background-color:#D9E2F3;color:#0070C0" %)**Response**
897 +|(% style="width:160px" %)AT+ SETCNT =0|(% style="width:221px" %)Set the count number to 0.|(% style="width:95px" %)OK
898 +|(% style="width:160px" %)AT+ SETCNT =100|(% style="width:221px" %)Set the count number to 100.|(% style="width:95px" %)OK
660 660  
900 +(% style="color:blue" %)**Downlink Command:**
661 661  
662 -It is due to channel mapping. Please see below link:  [[Frequency band>>doc:Main.LoRaWAN Communication Debug.WebHome||anchor="H2.NoticeofUS9152FCN4702FAU915Frequencyband"]]
902 +* **Example**: 0xA6000001  ~/~/  Same as AT+ SETCNT =1
663 663  
904 +* **Example**: 0xA6000064  ~/~/  Same as AT+ SETCNT =100
664 664  
665 -== 7. AT Command input doesn't work ==
906 +=== 3.3.8 Set Interrupt Mode ===
666 666  
667 667  
668 -In the case if user can see the console output but can't type input to the device. Please check if you already include the (% style="color:blue" %)**ENTER**(%%) while sending out the command. Some serial tool doesn't send (% style="color:blue" %)**ENTER**(%%) while press the send key, user need to add ENTER in their string.
909 +Feature, Set Interrupt mode for PA8 of pin.
669 669  
911 +When AT+INTMOD=0 is set, PA8 is used as a digital input port.
670 670  
671 -== 7.3  Why does the sensor reading show 0 or "No sensor" ==
913 +(% style="color:blue" %)**AT Command: AT+INTMOD**
672 672  
915 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %)
916 +|=(% style="width: 155px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 197px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 158px;background-color:#D9E2F3;color:#0070C0" %)**Response**
917 +|(% style="width:154px" %)AT+INTMOD=?|(% style="width:196px" %)Show current interrupt mode|(% style="width:157px" %)(((
918 +0
919 +OK
920 +the mode is 0 =Disable Interrupt
921 +)))
922 +|(% style="width:154px" %)AT+INTMOD=2|(% style="width:196px" %)(((
923 +Set Transmit Interval
924 +0. (Disable Interrupt),
925 +~1. (Trigger by rising and falling edge)
926 +2. (Trigger by falling edge)
927 +3. (Trigger by rising edge)
928 +)))|(% style="width:157px" %)OK
673 673  
674 -~1. The measurement object is very close to the sensor, but in the blind spot of the sensor.
930 +(% style="color:blue" %)**Downlink Command: 0x06**
675 675  
676 -2. Sensor wiring is disconnected
932 +Format: Command Code (0x06) followed by 3 bytes.
677 677  
678 -3. Not using the correct decoder
934 +This means that the interrupt mode of the end node is set to 0x000003=3 (rising edge trigger), and the type code is 06.
679 679  
936 +* Example 1: Downlink Payload: 06000000  ~/~/  Turn off interrupt mode
680 680  
681 -== 7.4  Abnormal readings The gap between multiple readings is too large or the gap between the readings and the actual value is too large ==
938 +* Example 2: Downlink Payload: 06000003  ~/~/  Set the interrupt mode to rising edge trigger
682 682  
940 +=== 3.3.9 Set work mode ===
683 683  
684 -1) Please check if there is something on the probe affecting its measurement (condensed water, volatile oil, etc.)
685 685  
686 -2) Does it change with temperature, temperature will affect its measurement
943 +Feature: Manually set the work mode
687 687  
688 -3) If abnormal data occurs, you can turn on DEBUG mode, Please use downlink or AT COMMAN to enter DEBUG mode.
689 689  
690 -downlink command: (% style="color:blue" %)**F1 01**(%%), AT command: (% style="color:blue" %)**AT+DDEBUG=1**
946 +(% style="color:blue" %)**AT Command: AT+MOD**
691 691  
692 -4) After entering the debug mode, it will send 20 pieces of data at a time, and you can send its uplink to us for analysis
948 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:463px" %)
949 +|=(% style="width: 162px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 193px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 108px;background-color:#D9E2F3;color:#0070C0" %)**Response**
950 +|(% style="width:162px" %)AT+MOD=0|(% style="width:191px" %)Set the work mode to 0.|(% style="width:106px" %)OK
951 +|(% style="width:162px" %)AT+MOD=1|(% style="width:191px" %)Set the work mode to 1|(% style="width:106px" %)OK
693 693  
694 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDDS75%20-%20LoRaWAN%20Distance%20Detection%20Sensor%20User%20Manual/WebHome/image-20230113135125-2.png?width=1057&height=136&rev=1.1||alt="image-20230113135125-2.png"]]
953 +(% style="color:blue" %)**Downlink Command:**
695 695  
955 +* **Example: **0x0A00  ~/~/  Same as AT+MOD=0
696 696  
697 -Its original payload will be longer than other data. Even though it is being parsed, it can be seen that it is abnormal data.
957 +* **Example:** 0x0A01  ~/~/  Same as AT+MOD=1
698 698  
699 -Please send the data to us for check.
959 += 4. Battery & Power Consumption =
700 700  
701 701  
702 -= 8. Order Info =
962 +SW3L-LB use ER26500 + SPC1520 battery pack. See below link for detail information about the battery info and how to replace.
703 703  
964 +[[**Battery Info & Power Consumption Analyze**>>http://wiki.dragino.com/xwiki/bin/view/Main/How%20to%20calculate%20the%20battery%20life%20of%20Dragino%20sensors%3F/]] .
704 704  
705 -Part Number: (% style="color:blue" %)**DDS75-LB-XXX**
706 706  
707 -(% style="color:red" %)**XXX**(%%): **The default frequency band**
967 += 5. OTA Firmware update =
708 708  
969 +
970 +(% class="wikigeneratedid" %)
971 +User can change firmware SW3L-LB to:
972 +
973 +* Change Frequency band/ region.
974 +
975 +* Update with new features.
976 +
977 +* Fix bugs.
978 +
979 +Firmware and changelog can be downloaded from : **[[Firmware download link>>url:https://www.dropbox.com/sh/kwqv57tp6pejias/AAAopYMATh1GM6fZ-VRCLrpDa?dl=0]]**
980 +
981 +Methods to Update Firmware:
982 +
983 +* (Recommanded way) OTA firmware update via wireless:   [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/Firmware%20OTA%20Update%20for%20Sensors/>>url:http://wiki.dragino.com/xwiki/bin/view/Main/Firmware%20OTA%20Update%20for%20Sensors/]]
984 +
985 +* Update through UART TTL interface. **[[Instruction>>url:http://wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H1.LoRaSTv4baseHardware]]**.
986 +
987 += 6. FAQ =
988 +
989 +== 6.1  AT Commands input doesn't work ==
990 +
991 +
992 +In the case if user can see the console output but can't type input to the device. Please check if you already include the (% style="color:green" %)**ENTER**(%%) while sending out the command. Some serial tool doesn't send (% style="color:green" %)**ENTER**(%%) while press the send key, user need to add ENTER in their string.
993 +
994 +
995 += 7. Order Info =
996 +
997 +
998 +Part Number: (% style="color:blue" %)**SW3L-LB-XXX-YYY**
999 +
1000 +(% style="color:red" %)**XXX**(%%): The default frequency band
1001 +
709 709  * (% style="color:red" %)**AS923**(%%): LoRaWAN AS923 band
710 710  
711 711  * (% style="color:red" %)**AU915**(%%): LoRaWAN AU915 band
... ... @@ -722,13 +722,43 @@
722 722  
723 723  * (% style="color:red" %)**CN470**(%%): LoRaWAN CN470 band
724 724  
1018 +(((
1019 +(% style="color:blue" %)**YYY**(%%): Flow Sensor Model:
1020 +)))
725 725  
726 -= 9. ​Packing Info =
1022 +(((
1023 + **004:** DW-004 Flow Sensor: diameter: G1/2” / DN15.  450 pulse = 1 L
1024 +)))
727 727  
1026 +(((
1027 + **006:** DW-006 Flow Sensor: diameter: G3/4” / DN20. 390 pulse = 1 L
1028 +)))
728 728  
1030 +(((
1031 + **010:** DW-010 Flow Sensor: diameter: G 1” / DN25. 64 pulse = 1 L
1032 +)))
1033 +
1034 +* (((
1035 +calculate flag=0: for SW3L-004 Flow Sensor: 450 pulse = 1 L
1036 +)))
1037 +
1038 +* (((
1039 +calculate flag=1: for SW3L-006 Flow Sensor: 390 pulse = 1 L
1040 +)))
1041 +
1042 +* (((
1043 +calculate flag=2: for SW3L-010 Flow Sensor: 64  pulse = 1 L
1044 +
1045 +
1046 +
1047 +)))
1048 +
1049 += 8. ​Packing Info =
1050 +
1051 +
729 729  (% style="color:#037691" %)**Package Includes**:
730 730  
731 -* DDS75-LB LoRaWAN Distance Detection Sensor x 1
1054 +* SW3L-LB LoRaWAN Flow Sensor
732 732  
733 733  (% style="color:#037691" %)**Dimension and weight**:
734 734  
... ... @@ -740,10 +740,9 @@
740 740  
741 741  * Weight / pcs : g
742 742  
1066 += 9. Support =
743 743  
744 -= 10. Support =
745 745  
746 -
747 747  * Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule.
748 748  
749 749  * Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[Support@dragino.cc>>mailto:Support@dragino.cc]].
image-20230613100900-1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -184.0 KB
Content