Changes for page DS20L -- LoRaWAN Smart Distance Detector User Manual 01
Last modified by Mengting Qiu on 2023/12/14 11:15
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -22,13 +22,13 @@ 22 22 23 23 It detects the distance(% style="color:blue" %)** between the measured object and the sensor**(%%), and uploads the value via wireless to LoRaWAN IoT Server. 24 24 25 -The LoRa wireless technology used in DDS75-LB allows device to send data and reach extremely long ranges at low data-rates. It provides ultra-long range spread spectrum communication and high interference immunity whilst minimizing current consumption.25 +The LoRa wireless technology used in SW3L-LB allows device to send data and reach extremely long ranges at low data-rates. It provides ultra-long range spread spectrum communication and high interference immunity whilst minimizing current consumption. 26 26 27 - DDS75-LB (% style="color:blue" %)**supports BLE configure**(%%) and (% style="color:blue" %)**wireless OTA update**(%%) which make user easy to use.27 +SW3L-LB (% style="color:blue" %)**supports BLE configure**(%%) and (% style="color:blue" %)**wireless OTA update**(%%) which make user easy to use. 28 28 29 - DDS75-LB is powered by (% style="color:blue" %)**8500mAh Li-SOCI2 battery**(%%), it is designed for long term use up to 5 years.29 +SW3L-LB is powered by (% style="color:blue" %)**8500mAh Li-SOCI2 battery**(%%), it is designed for long term use up to 5 years. 30 30 31 -Each DDS75-LB is pre-load with a set of unique keys for LoRaWAN registrations, register these keys to local LoRaWAN server and it will auto connect after power on.31 +Each SW3L-LB is pre-load with a set of unique keys for LoRaWAN registrations, register these keys to local LoRaWAN server and it will auto connect after power on. 32 32 33 33 [[image:image-20230612170943-2.png||height="525" width="912"]] 34 34 ... ... @@ -50,11 +50,36 @@ 50 50 * IP66 Waterproof Enclosure 51 51 * 8500mAh Battery for long term use 52 52 53 +== 1.3 Specification == 53 53 54 54 55 - ==1.3Specification==56 +(% style="color:#037691" %)**Rated environmental conditions:** 56 56 58 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:500px" %) 59 +|(% style="background-color:#d9e2f3; color:#0070c0; width:163px" %)**Item**|(% style="background-color:#d9e2f3; color:#0070c0; width:90px" %)((( 60 +**Minimum value** 61 +)))|(% style="background-color:#d9e2f3; color:#0070c0; width:70px" %)((( 62 +**Typical value** 63 +)))|(% style="background-color:#d9e2f3; color:#0070c0; width:87px" %)((( 64 +**Maximum value** 65 +)))|(% style="background-color:#d9e2f3; color:#0070c0; width:40px" %)**Unit**|(% style="background-color:#d9e2f3; color:#0070c0; width:50px" %)**Remarks** 66 +|(% style="width:174px" %)Storage temperature|(% style="width:86px" %)-25|(% style="width:66px" %)25|(% style="width:90px" %)80|(% style="width:48px" %)℃|(% style="width:203px" %) 67 +|(% style="width:174px" %)Storage humidity|(% style="width:86px" %) |(% style="width:66px" %)65%|(% style="width:90px" %)90%|(% style="width:48px" %)RH|(% style="width:203px" %)(1) 68 +|(% style="width:174px" %)Operating temperature|(% style="width:86px" %)-15|(% style="width:66px" %)25|(% style="width:90px" %)60|(% style="width:48px" %)℃|(% style="width:203px" %) 69 +|(% style="width:174px" %)Working humidity|(% style="width:86px" %)((( 70 + 57 57 72 + 73 +)))|(% style="width:66px" %)65%|(% style="width:90px" %)80%|(% style="width:48px" %)RH|(% style="width:203px" %)(1) 74 + 75 +((( 76 +**Remarks: (1) a. When the ambient temperature is 0-39 ℃, the maximum humidity is 90% (non-condensing); ** 77 + 78 +**~ b. When the ambient temperature is 40-50 ℃, the highest humidity is the highest humidity in the natural world at the current temperature (no condensation)** 79 + 80 + 81 +))) 82 + 58 58 (% style="color:#037691" %)**Common DC Characteristics:** 59 59 60 60 * Supply Voltage: built in 8500mAh Li-SOCI2 battery , 2.5v ~~ 3.6v ... ... @@ -80,50 +80,20 @@ 80 80 * Sleep Mode: 5uA @ 3.3v 81 81 * LoRa Transmit Mode: 125mA @ 20dBm, 82mA @ 14dBm 82 82 108 +== 1.4 Effective measurement range Reference beam pattern == 83 83 84 84 85 - ==1.4Rated environmentalconditions==111 +**~1. The tested object is a white cylindrical tube made of PVC, with a height of 100cm and a diameter of 7.5cm.** 86 86 87 - 88 -(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:500px" %) 89 -|(% style="background-color:#d9e2f3; color:#0070c0; width:163px" %)**Item**|(% style="background-color:#d9e2f3; color:#0070c0; width:90px" %)((( 90 -**Minimum value** 91 -)))|(% style="background-color:#d9e2f3; color:#0070c0; width:70px" %)((( 92 -**Typical value** 93 -)))|(% style="background-color:#d9e2f3; color:#0070c0; width:87px" %)((( 94 -**Maximum value** 95 -)))|(% style="background-color:#d9e2f3; color:#0070c0; width:40px" %)**Unit**|(% style="background-color:#d9e2f3; color:#0070c0; width:50px" %)**Remarks** 96 -|(% style="width:174px" %)Storage temperature|(% style="width:86px" %)-25|(% style="width:66px" %)25|(% style="width:90px" %)80|(% style="width:48px" %)℃|(% style="width:203px" %) 97 -|(% style="width:174px" %)Storage humidity|(% style="width:86px" %) |(% style="width:66px" %)65%|(% style="width:90px" %)90%|(% style="width:48px" %)RH|(% style="width:203px" %)(1) 98 -|(% style="width:174px" %)Operating temperature|(% style="width:86px" %)-15|(% style="width:66px" %)25|(% style="width:90px" %)60|(% style="width:48px" %)℃|(% style="width:203px" %) 99 -|(% style="width:174px" %)Working humidity|(% style="width:86px" %)((( 100 - 101 - 102 - 103 -)))|(% style="width:66px" %)65%|(% style="width:90px" %)80%|(% style="width:48px" %)RH|(% style="width:203px" %)(1) 104 - 105 -((( 106 -(% style="color:red" %)**Remarks: (1) a. When the ambient temperature is 0-39 ℃, the maximum humidity is 90% (non-condensing); ** 107 - 108 -(% style="color:red" %)** b. When the ambient temperature is 40-50 ℃, the highest humidity is the highest humidity in the natural world at the current temperature (no condensation)** 109 - 110 - 111 -))) 112 - 113 -== 1.5 Effective measurement range Reference beam pattern == 114 - 115 - 116 -(% style="color:blue" %)**1. The tested object is a white cylindrical tube made of PVC, with a height of 100cm and a diameter of 7.5cm.** 117 - 118 118 [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDDS75%20-%20LoRaWAN%20Distance%20Detection%20Sensor%20User%20Manual/WebHome/1654852253176-749.png?rev=1.1||alt="1654852253176-749.png"]] 119 119 120 120 121 - (% style="color:blue" %)**2. The object to be tested is a "corrugated cardboard box" perpendicular to the central axis of 0 °, and the length * width is 60cm * 50cm.**116 +**2. The object to be tested is a "corrugated cardboard box" perpendicular to the central axis of 0 °, and the length * width is 60cm * 50cm.** 122 122 123 123 [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDDS75%20-%20LoRaWAN%20Distance%20Detection%20Sensor%20User%20Manual/WebHome/1654852175653-550.png?rev=1.1||alt="1654852175653-550.png"]] 124 124 125 125 126 -== 1. 6Applications ==121 +== 1.5 Applications == 127 127 128 128 129 129 * Horizontal distance measurement ... ... @@ -136,17 +136,15 @@ 136 136 * Sewer 137 137 * Bottom water level monitoring 138 138 134 +== 1.6 Sleep mode and working mode == 139 139 140 140 141 -== 1.7 Sleep mode and working mode == 142 - 143 - 144 144 (% style="color:blue" %)**Deep Sleep Mode: **(%%)Sensor doesn't have any LoRaWAN activate. This mode is used for storage and shipping to save battery life. 145 145 146 146 (% style="color:blue" %)**Working Mode:** (%%)In this mode, Sensor will work as LoRaWAN Sensor to Join LoRaWAN network and send out sensor data to server. Between each sampling/tx/rx periodically, sensor will be in IDLE mode), in IDLE mode, sensor has the same power consumption as Deep Sleep mode. 147 147 148 148 149 -== 1. 8Button & LEDs ==142 +== 1.7 Button & LEDs == 150 150 151 151 152 152 [[image:Main.User Manual for LoRaWAN End Nodes.D20-LBD22-LBD23-LB_LoRaWAN_Temperature_Sensor_User_Manual.WebHome@1675071855856-879.png]] ... ... @@ -165,11 +165,9 @@ 165 165 ))) 166 166 |(% style="width:167px" %)Fast press ACT 5 times.|(% style="width:117px" %)Deactivate Device|(% style="width:225px" %)(% style="color:red" %)**Red led**(%%) will solid on for 5 seconds. Means device is in Deep Sleep Mode. 167 167 161 +== 1.8 BLE connection == 168 168 169 169 170 -== 1.9 BLE connection == 171 - 172 - 173 173 DDS75-LB support BLE remote configure. 174 174 175 175 ... ... @@ -182,14 +182,16 @@ 182 182 If there is no activity connection on BLE in 60 seconds, sensor will shut down BLE module to enter low power mode. 183 183 184 184 185 -== 1. 10Pin Definitions ==176 +== 1.9 Pin Definitions == 186 186 187 187 [[image:image-20230523174230-1.png]] 188 188 189 189 190 -== 1.11Mechanical==181 +== == 191 191 183 +== 2.10 Mechanical == 192 192 185 + 193 193 [[image:Main.User Manual for LoRaWAN End Nodes.D20-LBD22-LBD23-LB_LoRaWAN_Temperature_Sensor_User_Manual.WebHome@1675143884058-338.png]] 194 194 195 195 ... ... @@ -199,7 +199,7 @@ 199 199 [[image:Main.User Manual for LoRaWAN End Nodes.D20-LBD22-LBD23-LB_LoRaWAN_Temperature_Sensor_User_Manual.WebHome@1675143909447-639.png]] 200 200 201 201 202 - (% style="color:blue" %)**Probe Mechanical:**195 +**Probe Mechanical:** 203 203 204 204 205 205 [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDDS75%20-%20LoRaWAN%20Distance%20Detection%20Sensor%20User%20Manual/WebHome/image-20220610172003-1.png?rev=1.1||alt="image-20220610172003-1.png"]] ... ... @@ -275,13 +275,20 @@ 275 275 276 276 277 277 ((( 271 +((( 278 278 DDS75-LB will uplink payload via LoRaWAN with below payload format: 279 279 ))) 280 280 281 281 ((( 282 -Uplink payload includes in total 8 bytes. 276 +Uplink payload includes in total 4 bytes. 277 +Payload for firmware version v1.1.4. . Before v1.1.3, there is on two fields: BAT and Distance 283 283 ))) 279 +))) 284 284 281 +((( 282 + 283 +))) 284 + 285 285 (% border="1" cellspacing="5" style="background-color:#f2f2f2; width:510px" %) 286 286 |=(% style="width: 62.5px;background-color:#D9E2F3;color:#0070C0" %)((( 287 287 **Size(bytes)** ... ... @@ -321,14 +321,12 @@ 321 321 322 322 323 323 * If the sensor value is 0x0000, it means system doesn't detect ultrasonic sensor. 324 -* If the sensor value lower than 0x0118 (280mm), the sensor value will be invalid. All value lower than 280mm will be set to 0x0014(20mm) which means the value is invalid.324 +* If the sensor value lower than 0x0118 (280mm), the sensor value will be invalid. Since v1.1.4, all value lower than 280mm will be set to 0x0014(20mm) which means the value is invalid. 325 325 326 - 327 - 328 328 === 2.3.3 Interrupt Pin === 329 329 330 330 331 -This data field shows if this packet is generated by interrupt or not. [[Click here>>||anchor="H3.3 .2SetInterruptMode"]] for the hardware and software set up.329 +This data field shows if this packet is generated by interrupt or not. [[Click here>>||anchor="H3.3A0SetInterruptMode"]] for the hardware and software set up. 332 332 333 333 **Example:** 334 334 ... ... @@ -348,7 +348,9 @@ 348 348 349 349 If payload is: FF3FH : (FF3F & FC00 == 1) , temp = (FF3FH - 65536)/10 = -19.3 degrees. 350 350 349 +(% style="color:red" %)**Note: DS18B20 feature is supported in the hardware version > v1.3 which made since early of 2021.** 351 351 351 + 352 352 === 2.3.5 Sensor Flag === 353 353 354 354 ... ... @@ -378,7 +378,7 @@ 378 378 == 2.4 Uplink Interval == 379 379 380 380 381 -The DDS75-LB by default uplink the sensor data every 20 minutes. User can change this interval by AT Command or LoRaWAN Downlink Command. See this link: [[Change Uplink Interval>>||anchor="H 3.3.1SetTransmitIntervalTime"]]381 +The DDS75-LB by default uplink the sensor data every 20 minutes. User can change this interval by AT Command or LoRaWAN Downlink Command. See this link: [[Change Uplink Interval>>doc:Main.End Device AT Commands and Downlink Command.WebHome||anchor="H4.1ChangeUplinkInterval"]] 382 382 383 383 384 384 == 2.5 Show Data in DataCake IoT Server == ... ... @@ -388,6 +388,9 @@ 388 388 [[DATACAKE>>url:https://datacake.co/]] provides a human friendly interface to show the sensor data, once we have data in TTN, we can use [[DATACAKE>>url:https://datacake.co/]] to connect to TTN and see the data in DATACAKE. Below are the steps: 389 389 ))) 390 390 391 +((( 392 + 393 +))) 391 391 392 392 ((( 393 393 (% style="color:blue" %)**Step 1**(%%)**: Be sure that your device is programmed and properly connected to the network at this time.** ... ... @@ -420,19 +420,19 @@ 420 420 == 2.6 Datalog Feature == 421 421 422 422 423 -Datalog Feature is to ensure IoT Server can get all sampling data from Sensor even if the LoRaWAN network is down. For each sampling, DDS75-LB will store the reading for future retrieving purposes.426 +Datalog Feature is to ensure IoT Server can get all sampling data from Sensor even if the LoRaWAN network is down. For each sampling, SW3L-LB will store the reading for future retrieving purposes. 424 424 425 425 426 426 === 2.6.1 Ways to get datalog via LoRaWAN === 427 427 428 428 429 -Set PNACKMD=1, DDS75-LB will wait for ACK for every uplink, when there is no LoRaWAN network,DDS75-LB will mark these records with non-ack messages and store the sensor data, and it will send all messages (10s interval) after the network recovery.432 +Set PNACKMD=1, SW3L-LB will wait for ACK for every uplink, when there is no LoRaWAN network,SW3L-LB will mark these records with non-ack messages and store the sensor data, and it will send all messages (10s interval) after the network recovery. 430 430 431 431 * ((( 432 -a) DDS75-LB will do an ACK check for data records sending to make sure every data arrive server.435 +a) SW3L-LB will do an ACK check for data records sending to make sure every data arrive server. 433 433 ))) 434 434 * ((( 435 -b) DDS75-LB will send data in **CONFIRMED Mode** when PNACKMD=1, butDDS75-LB won't re-transmit the packet if it doesn't get ACK, it will just mark it as a NONE-ACK message. In a future uplink ifDDS75-LB gets a ACK,DDS75-LB will consider there is a network connection and resend all NONE-ACK messages.438 +b) SW3L-LB will send data in **CONFIRMED Mode** when PNACKMD=1, but SW3L-LB won't re-transmit the packet if it doesn't get ACK, it will just mark it as a NONE-ACK message. In a future uplink if SW3L-LB gets a ACK, SW3L-LB will consider there is a network connection and resend all NONE-ACK messages. 436 436 ))) 437 437 438 438 Below is the typical case for the auto-update datalog feature (Set PNACKMD=1) ... ... @@ -443,7 +443,7 @@ 443 443 === 2.6.2 Unix TimeStamp === 444 444 445 445 446 - DDS75-LB uses Unix TimeStamp format based on449 +SW3L-LB uses Unix TimeStamp format based on 447 447 448 448 [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/WebHome/image-20220523001219-11.png?width=627&height=97&rev=1.1||alt="图片-20220523001219-11.png" height="97" width="627"]] 449 449 ... ... @@ -462,7 +462,7 @@ 462 462 463 463 User need to set (% style="color:blue" %)**SYNCMOD=1**(%%) to enable sync time via MAC command. 464 464 465 -Once DDS75-LB Joined LoRaWAN network, it will send the MAC command (DeviceTimeReq) and the server will reply with (DeviceTimeAns) to send the current time toDDS75-LB. IfDDS75-LB fails to get the time from the server,DDS75-LB will use the internal time and wait for next time request (AT+SYNCTDC to set the time request period, default is 10 days).468 +Once SW3L-LB Joined LoRaWAN network, it will send the MAC command (DeviceTimeReq) and the server will reply with (DeviceTimeAns) to send the current time to SW3L-LB. If SW3L-LB fails to get the time from the server, SW3L-LB will use the internal time and wait for next time request (AT+SYNCTDC to set the time request period, default is 10 days). 466 466 467 467 (% style="color:red" %)**Note: LoRaWAN Server need to support LoRaWAN v1.0.3(MAC v1.0.3) or higher to support this MAC command feature, Chirpstack,TTN V3 v3 and loriot support but TTN V3 v2 doesn't support. If server doesn't support this command, it will through away uplink packet with this command, so user will lose the packet with time request for TTN V3 v2 if SYNCMOD=1.** 468 468 ... ... @@ -490,7 +490,7 @@ 490 490 ))) 491 491 492 492 ((( 493 -Uplink Internal =5s,means DDS75-LB will send one packet every 5s. range 5~~255s.496 +Uplink Internal =5s,means SW3L-LB will send one packet every 5s. range 5~~255s. 494 494 ))) 495 495 496 496 ... ... @@ -497,17 +497,17 @@ 497 497 == 2.7 Frequency Plans == 498 498 499 499 500 -The DDS75-LB uses OTAA mode and below frequency plans by default. If user want to use it with different frequency plan, please refer the AT command sets.503 +The SW3L-LB uses OTAA mode and below frequency plans by default. If user want to use it with different frequency plan, please refer the AT command sets. 501 501 502 502 [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20Frequency%20Band/>>http://wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20Frequency%20Band/]] 503 503 504 504 505 -= 3. Configure DDS75-LB =508 += 3. Configure SW3L-LB = 506 506 507 507 == 3.1 Configure Methods == 508 508 509 509 510 - DDS75-LB supports below configure method:513 +SW3L-LB supports below configure method: 511 511 512 512 * AT Command via Bluetooth Connection (**Recommended**): [[BLE Configure Instruction>>http://wiki.dragino.com/xwiki/bin/view/Main/BLE%20Bluetooth%20Remote%20Configure/]]. 513 513 ... ... @@ -515,8 +515,6 @@ 515 515 516 516 * LoRaWAN Downlink. Instruction for different platforms: See [[IoT LoRaWAN Server>>http://wiki.dragino.com/xwiki/bin/view/Main/]] section. 517 517 518 - 519 - 520 520 == 3.2 General Commands == 521 521 522 522 ... ... @@ -531,10 +531,10 @@ 531 531 [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/>>http://wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/]] 532 532 533 533 534 -== 3.3 Commands special design for DDS75-LB ==535 +== 3.3 Commands special design for SW3L-LB == 535 535 536 536 537 -These commands only valid for DDS75-LB, as below:538 +These commands only valid for SW3L-LB, as below: 538 538 539 539 540 540 === 3.3.1 Set Transmit Interval Time === ... ... @@ -577,143 +577,261 @@ 577 577 ))) 578 578 * ((( 579 579 Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds 581 +))) 580 580 583 +=== 3.3.2 Quit AT Command === 581 581 582 - 585 + 586 +Feature: Quit AT Command mode, so user needs to input the password again before using AT Commands. 587 + 588 +(% style="color:blue" %)**AT Command: AT+DISAT** 589 + 590 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:452px" %) 591 +|=(% style="width: 155px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 198px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 99px;background-color:#D9E2F3;color:#0070C0" %)**Response** 592 +|(% style="width:155px" %)AT+DISAT|(% style="width:198px" %)Quit AT Commands mode|(% style="width:96px" %)OK 593 + 594 +(% style="color:blue" %)**Downlink Command:** 595 + 596 +No downlink command for this feature. 597 + 598 + 599 +=== 3.3.3 Get Device Status === 600 + 601 + 602 +Send a LoRaWAN downlink to ask device send Alarm settings. 603 + 604 +(% style="color:blue" %)**Downlink Payload: **(%%)0x26 01 605 + 606 +Sensor will upload Device Status via FPORT=5. See payload section for detail. 607 + 608 + 609 +=== 3.3.4 Alarm for continuously water flow === 610 + 611 + 612 +((( 613 +This feature is to monitor and send Alarm for continuously water flow. 583 583 ))) 584 584 585 -=== 3.3.2 Set Interrupt Mode === 616 +((( 617 +Example case is for Toilet water monitoring, if some one push toilet button, the toilet will have water flow. If the toilet button has broken and can't returned to original state, the water flow will keep for hours or days which cause huge waste for water. 618 +))) 586 586 620 +((( 621 +To monitor this faulty and send alarm, there are two settings: 622 +))) 587 587 588 -Feature, Set Interrupt mode for PA8 of pin. 624 +* ((( 625 +(% style="color:#4f81bd" %)**Stop Duration: Unit: Second** 626 +))) 589 589 590 -When AT+INTMOD=0 is set, PA8 is used as a digital input port. 628 +((( 629 +Default: 15s, If SW3L-LB didn't see any water flow in 15s, SW3L-LB will consider stop of water flow event. 630 +))) 591 591 592 -(% style="color:blue" %)**AT Command: AT+INTMOD** 632 +* ((( 633 +(% style="color:#4f81bd" %)**Alarm Timer: Units: Minute; Default 0 minutes (means Alarm disable)** 634 +))) 593 593 594 -(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %) 595 -|=(% style="width: 155px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 197px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 158px;background-color:#D9E2F3;color:#0070C0" %)**Response** 596 -|(% style="width:154px" %)AT+INTMOD=?|(% style="width:196px" %)Show current interrupt mode|(% style="width:157px" %)((( 597 -0 598 -OK 599 -the mode is 0 =Disable Interrupt 636 +((( 637 +**Example:** 3 minutes, if SW3L-LB detect a start of water flow event and didn't detect a stop event within Alarm timer, SW3L-LB will send an Alarm to indicate a water flow abnormal alarm. 600 600 ))) 601 -|(% style="width:154px" %)AT+INTMOD=2|(% style="width:196px" %)((( 602 -Set Transmit Interval 603 -0. (Disable Interrupt), 604 -~1. (Trigger by rising and falling edge) 605 -2. (Trigger by falling edge) 606 -3. (Trigger by rising edge) 607 -)))|(% style="width:157px" %)OK 608 608 609 -(% style="color:blue" %)**Downlink Command: 0x06** 640 +((( 641 +So for example, If we set stop duration=15s and Alarm Timer=3minutes. If the toilet water flow continuously for more than 3 minutes, Sensor will send an alarm (in Confirmed MODE) to platform. 642 +))) 610 610 611 -Format: Command Code (0x06) followed by 3 bytes. 644 +((( 645 +(% style="color:red" %)**Note:** **After this alarm is send, sensor will consider a stop of water flow and count for another new event. So if water flow waste last for 1 hour, Sensor will keep sending alarm every 3 minutes.** 646 +))) 612 612 613 -This means that the interrupt mode of the end node is set to 0x000003=3 (rising edge trigger), and the type code is 06. 648 +((( 649 +(% style="color:#4f81bd" %)**AT Command**(%%) to configure: 650 +))) 614 614 615 -* Example 1: Downlink Payload: 06000000 ~/~/ Turn off interrupt mode 652 +* ((( 653 +AT+PTRIG=15,3 ~-~-> Set Stop duration: 15s, Alarm Timer: 3 minutes. 654 +))) 616 616 617 -* Example 2: Downlink Payload: 06000003 ~/~/ Set the interrupt mode to rising edge trigger 656 +* ((( 657 +AT+ PTRIG=15,0 ~-~-> Default Value, disable water waste Alarm. 658 +))) 618 618 660 +((( 661 +(% style="color:#4f81bd" %)**Downlink Command**(%%) to configure: 662 +))) 619 619 664 +((( 665 +Command: **0xAA aa bb cc** 666 +))) 620 620 621 -= 4. Battery & Power Consumption = 668 +((( 669 +AA: Command Type Code 670 +))) 622 622 672 +((( 673 +aa: Stop duration 674 +))) 623 623 624 -DDS75-LB use ER26500 + SPC1520 battery pack. See below link for detail information about the battery info and how to replace. 676 +((( 677 +bb cc: Alarm Timer 678 +))) 625 625 626 -[[**Battery Info & Power Consumption Analyze**>>http://wiki.dragino.com/xwiki/bin/view/Main/How%20to%20calculate%20the%20battery%20life%20of%20Dragino%20sensors%3F/]] . 680 +((( 681 +If user send 0xAA 0F 00 03: equal to AT+PTRIG=15,3 682 +))) 627 627 628 628 629 -= 5.OTA Firmwareupdate =685 +=== 3.3.5 Clear Flash Record === 630 630 631 631 632 -(% class="wikigeneratedid" %) 633 -User can change firmware DDS75-LB to: 688 +Feature: Clear flash storage for data log feature. 634 634 635 - *ChangeFrequencyband/region.690 +(% style="color:blue" %)**AT Command: AT+CLRDTA** 636 636 637 -* Update with new features. 692 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:500px" %) 693 +|=(% style="width: 157px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 169px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 174px;background-color:#D9E2F3;color:#0070C0" %)**Response** 694 +|(% style="width:157px" %)AT+CLRDTA|(% style="width:169px" %)Clear flash storage for data log feature.|Clear all stored sensor data… OK 638 638 639 -* Fix bugs. 696 +((( 697 +(% style="color:blue" %)**Downlink Command:** 698 +))) 640 640 641 -Firmware and changelog can be downloaded from : **[[Firmware download link>>url:https://www.dropbox.com/sh/7la95mae0fn03xe/AACtzs-32m22TLb75B-iIr-Qa?dl=0]]** 700 +((( 701 +* **Example**: 0xA301 ~/~/ Same as AT+CLRDTA 702 +))) 642 642 643 -Methods to Update Firmware: 644 644 645 -* (Recommanded way) OTA firmware update via wireless: [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/Firmware%20OTA%20Update%20for%20Sensors/>>url:http://wiki.dragino.com/xwiki/bin/view/Main/Firmware%20OTA%20Update%20for%20Sensors/]] 646 646 647 - *UpdatethroughUART TTL interface: **[[Instruction>>url:http://wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H1.LoRaSTv4baseHardware]]**.706 +=== 3.3.6 Set the calculate flag === 648 648 649 649 709 +Feature: Set the calculate flag 650 650 651 -= 6.FAQ =711 +(% style="color:blue" %)**AT Command: AT+CALCFLAG** 652 652 653 -== 6.1 What is the frequency plan for DDS75-LB? == 713 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:461px" %) 714 +|=(% style="width: 158px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 193px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 110px;background-color:#D9E2F3;color:#0070C0" %)**Response** 715 +|(% style="width:158px" %)AT+CALCFLAG =1|(% style="width:192px" %)Set the calculate flag to 1.|(% style="width:109px" %)OK 716 +|(% style="width:158px" %)AT+CALCFLAG =2|(% style="width:192px" %)Set the calculate flag to 2.|(% style="width:109px" %)OK 654 654 718 +(% style="color:blue" %)**Downlink Command:** 655 655 656 - DDS75-LBuse the samefrequencyasotherDraginoproducts.Usercanseethedetail fromthislink: [[Introduction>>doc:Main.End DeviceFrequencyBand.WebHome||anchor="H1.Introduction"]]720 +* **Example**: 0XA501 ~/~/ Same as AT+CALCFLAG =1 657 657 722 +=== 3.3.7 Set count number === 658 658 659 -== 6.2 Can I use DDS75-LB in condensation environment? == 660 660 725 +Feature: Manually set the count number 661 661 662 - DDS75-LBisnotsuitableto be used incondensation environment. Condensation on the DDS75-LB probe will affectthereading andalways got 0.727 +(% style="color:blue" %)**AT Command: AT+SETCNT** 663 663 729 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:479px" %) 730 +|=(% style="width: 160px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 223px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 96px;background-color:#D9E2F3;color:#0070C0" %)**Response** 731 +|(% style="width:160px" %)AT+ SETCNT =0|(% style="width:221px" %)Set the count number to 0.|(% style="width:95px" %)OK 732 +|(% style="width:160px" %)AT+ SETCNT =100|(% style="width:221px" %)Set the count number to 100.|(% style="width:95px" %)OK 664 664 665 - =7. TroubleShooting=734 +(% style="color:blue" %)**Downlink Command:** 666 666 667 - ==7.1WhyIcan'tjoinTTNV3 in US915/AU915bands?==736 +* **Example**: 0xA6000001 ~/~/ Same as AT+ SETCNT =1 668 668 738 +* **Example**: 0xA6000064 ~/~/ Same as AT+ SETCNT =100 669 669 670 - Itisdueochannel mapping. Please see below link: [[Frequencyband>>doc:Main.LoRaWAN Communication Debug.WebHome||anchor="H2.NoticeofUS9152FCN4702FAU915Frequencyband"]]740 +=== 3.3.8 Set Interrupt Mode === 671 671 672 672 673 - ==7.2AT Command inputdoesn'twork==743 +Feature, Set Interrupt mode for PA8 of pin. 674 674 745 +When AT+INTMOD=0 is set, PA8 is used as a digital input port. 675 675 676 - In the case if user can see the console output but can't type input to the device. Please check if you already include the(% style="color:blue" %)**ENTER**(%%)while sendingout the command. Some serial tool doesn't send (% style="color:blue"%)**ENTER**(%%) while press the send key, user need to add ENTER in their string.747 +(% style="color:blue" %)**AT Command: AT+INTMOD** 677 677 749 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %) 750 +|=(% style="width: 155px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 197px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 158px;background-color:#D9E2F3;color:#0070C0" %)**Response** 751 +|(% style="width:154px" %)AT+INTMOD=?|(% style="width:196px" %)Show current interrupt mode|(% style="width:157px" %)((( 752 +0 753 +OK 754 +the mode is 0 =Disable Interrupt 755 +))) 756 +|(% style="width:154px" %)AT+INTMOD=2|(% style="width:196px" %)((( 757 +Set Transmit Interval 758 +0. (Disable Interrupt), 759 +~1. (Trigger by rising and falling edge) 760 +2. (Trigger by falling edge) 761 +3. (Trigger by rising edge) 762 +)))|(% style="width:157px" %)OK 678 678 679 - ==7.3 Why doeshesensorreadingshow0or "No sensor"==764 +(% style="color:blue" %)**Downlink Command: 0x06** 680 680 766 +Format: Command Code (0x06) followed by 3 bytes. 681 681 682 - ~1.Themeasurementobject is verycloseto thesensor,but intheblindspotofthesensor.768 +This means that the interrupt mode of the end node is set to 0x000003=3 (rising edge trigger), and the type code is 06. 683 683 684 - 2.Sensorwiringisdisconnected770 +* Example 1: Downlink Payload: 06000000 ~/~/ Turn off interrupt mode 685 685 686 - 3.Notusingthecorrect decoder772 +* Example 2: Downlink Payload: 06000003 ~/~/ Set the interrupt mode to rising edge trigger 687 687 774 +=== 3.3.9 Set work mode === 688 688 689 -== 7.4 Abnormal readings The gap between multiple readings is too large or the gap between the readings and the actual value is too large == 690 690 777 +Feature: Manually set the work mode 691 691 692 -1) Please check if there is something on the probe affecting its measurement (condensed water, volatile oil, etc.) 693 693 694 - 2)Doesitchangewith temperature,temperaturewill affect itsmeasurement780 +(% style="color:blue" %)**AT Command: AT+MOD** 695 695 696 -3) If abnormal data occurs, you can turn on DEBUG mode, Please use downlink or AT COMMAN to enter DEBUG mode. 782 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:463px" %) 783 +|=(% style="width: 162px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 193px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 108px;background-color:#D9E2F3;color:#0070C0" %)**Response** 784 +|(% style="width:162px" %)AT+MOD=0|(% style="width:191px" %)Set the work mode to 0.|(% style="width:106px" %)OK 785 +|(% style="width:162px" %)AT+MOD=1|(% style="width:191px" %)Set the work mode to 1|(% style="width:106px" %)OK 697 697 698 - downlink command:(% style="color:blue" %)**F101**(%%), AT command:(% style="color:blue" %)**AT+DDEBUG=1**787 +(% style="color:blue" %)**Downlink Command:** 699 699 700 - 4)After entering the debugmode, it will send20piecesofdataatatime,and you can sendits uplink to us foranalysis789 +* **Example: **0x0A00 ~/~/ Same as AT+MOD=0 701 701 702 - [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDDS75%20-%20LoRaWAN%20Distance%20Detection%20Sensor%20User%20Manual/WebHome/image-20230113135125-2.png?width=1057&height=136&rev=1.1||alt="image-20230113135125-2.png"]]791 +* **Example:** 0x0A01 ~/~/ Same as AT+MOD=1 703 703 793 += 4. Battery & Power Consumption = 704 704 705 -Its original payload will be longer than other data. Even though it is being parsed, it can be seen that it is abnormal data. 706 706 707 -P leasesendthedata to usforcheck.796 +SW3L-LB use ER26500 + SPC1520 battery pack. See below link for detail information about the battery info and how to replace. 708 708 798 +[[**Battery Info & Power Consumption Analyze**>>http://wiki.dragino.com/xwiki/bin/view/Main/How%20to%20calculate%20the%20battery%20life%20of%20Dragino%20sensors%3F/]] . 709 709 710 -= 8. Order Info = 711 711 801 += 5. OTA Firmware update = 712 712 713 -Part Number: (% style="color:blue" %)**DDS75-LB-XXX** 714 714 715 -(% style="color:red" %)**XXX**(%%): **The default frequency band** 804 +(% class="wikigeneratedid" %) 805 +User can change firmware SW3L-LB to: 716 716 807 +* Change Frequency band/ region. 808 + 809 +* Update with new features. 810 + 811 +* Fix bugs. 812 + 813 +Firmware and changelog can be downloaded from : **[[Firmware download link>>url:https://www.dropbox.com/sh/kwqv57tp6pejias/AAAopYMATh1GM6fZ-VRCLrpDa?dl=0]]** 814 + 815 +Methods to Update Firmware: 816 + 817 +* (Recommanded way) OTA firmware update via wireless: [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/Firmware%20OTA%20Update%20for%20Sensors/>>url:http://wiki.dragino.com/xwiki/bin/view/Main/Firmware%20OTA%20Update%20for%20Sensors/]] 818 + 819 +* Update through UART TTL interface. **[[Instruction>>url:http://wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H1.LoRaSTv4baseHardware]]**. 820 + 821 += 6. FAQ = 822 + 823 +== 6.1 AT Commands input doesn't work == 824 + 825 + 826 +In the case if user can see the console output but can't type input to the device. Please check if you already include the (% style="color:green" %)**ENTER**(%%) while sending out the command. Some serial tool doesn't send (% style="color:green" %)**ENTER**(%%) while press the send key, user need to add ENTER in their string. 827 + 828 + 829 += 7. Order Info = 830 + 831 + 832 +Part Number: (% style="color:blue" %)**SW3L-LB-XXX-YYY** 833 + 834 +(% style="color:red" %)**XXX**(%%): The default frequency band 835 + 717 717 * (% style="color:red" %)**AS923**(%%): LoRaWAN AS923 band 718 718 719 719 * (% style="color:red" %)**AU915**(%%): LoRaWAN AU915 band ... ... @@ -730,14 +730,43 @@ 730 730 731 731 * (% style="color:red" %)**CN470**(%%): LoRaWAN CN470 band 732 732 852 +((( 853 +(% style="color:blue" %)**YYY**(%%): Flow Sensor Model: 854 +))) 733 733 856 +((( 857 + **004:** DW-004 Flow Sensor: diameter: G1/2” / DN15. 450 pulse = 1 L 858 +))) 734 734 735 -= 9. Packing Info = 860 +((( 861 + **006:** DW-006 Flow Sensor: diameter: G3/4” / DN20. 390 pulse = 1 L 862 +))) 736 736 864 +((( 865 + **010:** DW-010 Flow Sensor: diameter: G 1” / DN25. 64 pulse = 1 L 866 +))) 737 737 868 +* ((( 869 +calculate flag=0: for SW3L-004 Flow Sensor: 450 pulse = 1 L 870 +))) 871 + 872 +* ((( 873 +calculate flag=1: for SW3L-006 Flow Sensor: 390 pulse = 1 L 874 +))) 875 + 876 +* ((( 877 +calculate flag=2: for SW3L-010 Flow Sensor: 64 pulse = 1 L 878 + 879 + 880 + 881 +))) 882 + 883 += 8. Packing Info = 884 + 885 + 738 738 (% style="color:#037691" %)**Package Includes**: 739 739 740 -* DDS75-LB LoRaWANDistance DetectionSensorx 1888 +* SW3L-LB LoRaWAN Flow Sensor 741 741 742 742 (% style="color:#037691" %)**Dimension and weight**: 743 743 ... ... @@ -749,11 +749,9 @@ 749 749 750 750 * Weight / pcs : g 751 751 900 += 9. Support = 752 752 753 753 754 -= 10. Support = 755 - 756 - 757 757 * Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule. 758 758 759 759 * Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[Support@dragino.cc>>mailto:Support@dragino.cc]].