Changes for page DS20L -- LoRaWAN Smart Distance Detector User Manual 01
Last modified by Mengting Qiu on 2023/12/14 11:15
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -18,18 +18,20 @@ 18 18 == 1.1 What is LoRaWAN Distance Detection Sensor == 19 19 20 20 21 -The Dragino DDS75-LB is a (% style="color:blue" %)**Distance DetectionSensor**(%%)for Internet of Things solution. Itis usedto measurethedistance betweenthesensorand aflatobject.Thedistancedetectionsensor isamodule thatuses (% style="color:blue"%)** ultrasonic sensingtechnology**(%%)for (%style="color:blue"%)**distancemeasurement**(%%),and (%style="color:blue" %)**temperature compensation**(%%) is performed internally toimprovethereliability of data. TheDDS75-LB can be applied to scenariossuch ashorizontal distance measurement, liquid level measurement, parkingmanagementsystem,object proximityand presence detection, intelligent trash can management system, robot obstacle avoidance, automatic control, sewer, bottom water level monitoring, etc.21 +The Dragino SW3L-LB is a (% style="color:blue" %)**LoRaWAN Flow Sensor**(%%). It detects water flow volume and uplink to IoT server via LoRaWAN network. User can use this to(% style="color:blue" %)** monitor the water usage for buildings.** 22 22 23 - Itdetectsthedistance(% style="color:blue" %)**betweenthemeasuredobjectand the sensor**(%%),and uploadsthevalueviawirelesstoLoRaWANIoT Server.23 +The SW3L-LB will send water flow volume every 20 minutes. It can also (% style="color:blue" %)**detect the water flow status**(%%) and (% style="color:blue" %)**send Alarm**(%%), to avoid the waste for water usage such as broken toilet case. 24 24 25 - TheLoRawirelesstechnology usedinDDS75-LBallowsdeviceto senddata andreachxtremely longrangesat lowdata-rates.It providesultra-longrangespreadspectrumcommunicationandhighinterference immunity whilst minimizing current consumption.25 +SW3L-LB is designed for both indoor and outdoor use. It has a weatherproof enclosure and industrial level battery to work in low to high temperatures. 26 26 27 - DDS75-LB (%style="color:blue"%)**supportsBLEconfigure**(%%)and (%style="color:blue"%)**wirelessOTAupdate**(%%) whichmakeuserasy touse.27 +The LoRa wireless technology used in SW3L-LB allows device to send data and reach extremely long ranges at low data-rates. It provides ultra-long range spread spectrum communication and high interference immunity whilst minimizing current consumption. 28 28 29 - DDS75-LBis poweredby(% style="color:blue" %)**8500mAh Li-SOCI2battery**(%%),itis designed forlong term useupto5 years.29 +SW3L-LB (% style="color:blue" %)**supports BLE configure**(%%) and (% style="color:blue" %)**wireless OTA update**(%%) which make user easy to use. 30 30 31 - Each DDS75-LB is pre-loadwithasetfuniquekeys for LoRaWANregistrations, register thesekeysto localLoRaWANserveranditwill autoconnectafterpower on.31 +SW3L-LB is powered by (% style="color:blue" %)**8500mAh Li-SOCI2 battery**(%%), it is designed for long term use up to 5 years. 32 32 33 +Each SW3L-LB is pre-load with a set of unique keys for LoRaWAN registrations, register these keys to local LoRaWAN server and it will auto connect after power on. 34 + 33 33 [[image:image-20230612170943-2.png||height="525" width="912"]] 34 34 35 35 ... ... @@ -39,19 +39,17 @@ 39 39 * LoRaWAN 1.0.3 Class A 40 40 * Bands: CN470/EU433/KR920/US915/EU868/AS923/AU915/IN865 41 41 * Ultra-low power consumption 42 -* DistanceDetectionby Ultrasonictechnology43 -* Flatobjectnge280mm - 7500mm44 -* A ccuracy:±(1cm+S*0.3%) (S: Distance)45 -* CableLength : 25cm44 +* Upload water flow volume 45 +* Monitor water waste 46 +* AT Commands to change parameters 47 +* supports Datalog feature 46 46 * Support Bluetooth v5.1 and LoRaWAN remote configure 47 47 * Support wireless OTA update firmware 48 -* ATCommandstohangeparameters50 +* Uplink on periodically and open/close event 49 49 * Downlink to change configure 50 -* IP66 Waterproof Enclosure 51 51 * 8500mAh Battery for long term use 52 52 53 53 54 - 55 55 == 1.3 Specification == 56 56 57 57 ... ... @@ -81,69 +81,24 @@ 81 81 * LoRa Transmit Mode: 125mA @ 20dBm, 82mA @ 14dBm 82 82 83 83 84 -== 1.4 Rated environmentalconditions ==84 +== 1.4 Applications == 85 85 86 86 87 -(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:500px" %) 88 -|(% style="background-color:#d9e2f3; color:#0070c0; width:163px" %)**Item**|(% style="background-color:#d9e2f3; color:#0070c0; width:90px" %)((( 89 -**Minimum value** 90 -)))|(% style="background-color:#d9e2f3; color:#0070c0; width:70px" %)((( 91 -**Typical value** 92 -)))|(% style="background-color:#d9e2f3; color:#0070c0; width:87px" %)((( 93 -**Maximum value** 94 -)))|(% style="background-color:#d9e2f3; color:#0070c0; width:40px" %)**Unit**|(% style="background-color:#d9e2f3; color:#0070c0; width:50px" %)**Remarks** 95 -|(% style="width:174px" %)Storage temperature|(% style="width:86px" %)-25|(% style="width:66px" %)25|(% style="width:90px" %)80|(% style="width:48px" %)℃|(% style="width:203px" %) 96 -|(% style="width:174px" %)Storage humidity|(% style="width:86px" %) |(% style="width:66px" %)65%|(% style="width:90px" %)90%|(% style="width:48px" %)RH|(% style="width:203px" %)(1) 97 -|(% style="width:174px" %)Operating temperature|(% style="width:86px" %)-15|(% style="width:66px" %)25|(% style="width:90px" %)60|(% style="width:48px" %)℃|(% style="width:203px" %) 98 -|(% style="width:174px" %)Working humidity|(% style="width:86px" %)((( 99 - 87 +* Flow Sensor application 88 +* Water Control 89 +* Toilet Flow Sensor 90 +* Monitor Waste water 100 100 101 - 102 -)))|(% style="width:66px" %)65%|(% style="width:90px" %)80%|(% style="width:48px" %)RH|(% style="width:203px" %)(1) 103 103 104 -((( 105 -(% style="color:red" %)**Remarks: (1) a. When the ambient temperature is 0-39 ℃, the maximum humidity is 90% (non-condensing); ** 93 +== 1.5 Sleep mode and working mode == 106 106 107 -(% style="color:red" %)** b. When the ambient temperature is 40-50 ℃, the highest humidity is the highest humidity in the natural world at the current temperature (no condensation)** 108 108 109 - 110 -))) 111 - 112 -== 1.5 Effective measurement range Reference beam pattern == 113 - 114 - 115 -(% style="color:blue" %)**1. The tested object is a white cylindrical tube made of PVC, with a height of 100cm and a diameter of 7.5cm.** 116 - 117 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDDS75%20-%20LoRaWAN%20Distance%20Detection%20Sensor%20User%20Manual/WebHome/1654852253176-749.png?rev=1.1||alt="1654852253176-749.png"]] 118 - 119 - 120 -(% style="color:blue" %)**2. The object to be tested is a "corrugated cardboard box" perpendicular to the central axis of 0 °, and the length * width is 60cm * 50cm.** 121 - 122 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDDS75%20-%20LoRaWAN%20Distance%20Detection%20Sensor%20User%20Manual/WebHome/1654852175653-550.png?rev=1.1||alt="1654852175653-550.png"]] 123 - 124 - 125 -== 1.6 Applications == 126 - 127 - 128 -* Horizontal distance measurement 129 -* Liquid level measurement 130 -* Parking management system 131 -* Object proximity and presence detection 132 -* Intelligent trash can management system 133 -* Robot obstacle avoidance 134 -* Automatic control 135 -* Sewer 136 -* Bottom water level monitoring 137 - 138 -== 1.7 Sleep mode and working mode == 139 - 140 - 141 141 (% style="color:blue" %)**Deep Sleep Mode: **(%%)Sensor doesn't have any LoRaWAN activate. This mode is used for storage and shipping to save battery life. 142 142 143 143 (% style="color:blue" %)**Working Mode:** (%%)In this mode, Sensor will work as LoRaWAN Sensor to Join LoRaWAN network and send out sensor data to server. Between each sampling/tx/rx periodically, sensor will be in IDLE mode), in IDLE mode, sensor has the same power consumption as Deep Sleep mode. 144 144 145 145 146 -== 1. 8Button & LEDs ==101 +== 1.6 Button & LEDs == 147 147 148 148 149 149 [[image:Main.User Manual for LoRaWAN End Nodes.D20-LBD22-LBD23-LB_LoRaWAN_Temperature_Sensor_User_Manual.WebHome@1675071855856-879.png]] ... ... @@ -162,12 +162,13 @@ 162 162 ))) 163 163 |(% style="width:167px" %)Fast press ACT 5 times.|(% style="width:117px" %)Deactivate Device|(% style="width:225px" %)(% style="color:red" %)**Red led**(%%) will solid on for 5 seconds. Means device is in Deep Sleep Mode. 164 164 165 -== 1.9 BLE connection == 166 166 121 +== 1.7 BLE connection == 167 167 168 -DDS75-LB support BLE remote configure. 169 169 124 +SW3L-LB support BLE remote configure. 170 170 126 + 171 171 BLE can be used to configure the parameter of sensor or see the console output from sensor. BLE will be only activate on below case: 172 172 173 173 * Press button to send an uplink ... ... @@ -177,16 +177,27 @@ 177 177 If there is no activity connection on BLE in 60 seconds, sensor will shut down BLE module to enter low power mode. 178 178 179 179 180 -== 1. 10Pin Definitions ==136 +== 1.8 Pin Definitions == 181 181 182 182 [[image:image-20230523174230-1.png]] 183 183 184 184 141 +== 1.9 Flow Sensor Spec == 185 185 186 186 187 -== 1.11 Mechanical == 144 +((( 145 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:510px" %) 146 +|=(% style="width: 80px;background-color:#D9E2F3;color:#0070C0" %)**Model**|=(% style="width: 80px;background-color:#D9E2F3;color:#0070C0" %)**Probe**|=(% style="width: 80px;background-color:#D9E2F3;color:#0070C0" %)**Diameter**|=(% style="width: 80px;background-color:#D9E2F3;color:#0070C0" %)**Range**|=(% style="width: 80px;background-color:#D9E2F3;color:#0070C0" %)**Max Pressure**|=(% style="width: 110px;background-color:#D9E2F3;color:#0070C0" %)**Measure** 147 +|(% style="width:88px" %)SW3L-004|(% style="width:75px" %)DW-004|(% style="width:107px" %)G1/2" /DN15|(% style="width:101px" %)1~~30L/min|(% style="width:116px" %)≤ 2.0Mpa|(% style="width:124px" %)450 pulse = 1 L 148 +|(% style="width:88px" %)SW3L-006|(% style="width:75px" %)DW-006|(% style="width:107px" %)G3/4" /DN20|(% style="width:101px" %)1~~60L/min|(% style="width:116px" %)≤ 1.2Mpa|(% style="width:124px" %)390 pulse = 1 L 149 +|(% style="width:88px" %)SW3L-010|(% style="width:75px" %)DW-010|(% style="width:107px" %)G 1" /DN25|(% style="width:101px" %)2~~100L/min|(% style="width:116px" %)≤ 2.0Mpa|(% style="width:124px" %)64 pulse = 1 L 150 +))) 188 188 189 189 153 + 154 +== 2.10 Mechanical == 155 + 156 + 190 190 [[image:Main.User Manual for LoRaWAN End Nodes.D20-LBD22-LBD23-LB_LoRaWAN_Temperature_Sensor_User_Manual.WebHome@1675143884058-338.png]] 191 191 192 192 ... ... @@ -196,24 +196,27 @@ 196 196 [[image:Main.User Manual for LoRaWAN End Nodes.D20-LBD22-LBD23-LB_LoRaWAN_Temperature_Sensor_User_Manual.WebHome@1675143909447-639.png]] 197 197 198 198 199 -(% style="color:blue" %)** ProbeMechanical:**166 +(% style="color:blue" %)**DW-004 Flow Sensor: diameter: G1/2” / DN15. 450 pulse = 1 L** 200 200 168 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/SW3L%20LoRaWAN%20Outdoor%20Flow%20Sensor/WebHome/image-20220519091350-1.png?width=722&height=385&rev=1.1||alt="image-20220519091350-1.png"]] 201 201 202 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDDS75%20-%20LoRaWAN%20Distance%20Detection%20Sensor%20User%20Manual/WebHome/image-20220610172003-1.png?rev=1.1||alt="image-20220610172003-1.png"]] 203 203 171 +(% style="color:blue" %)**006: DW-006 Flow Sensor: diameter: G3/4” / DN20. 390 pulse = 1 L** 204 204 205 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/ LDDS75%20-%20LoRaWAN%20Distance%20Detection%20Sensor%20User%20Manual/WebHome/image-20220610172003-2.png?rev=1.1||alt="image-20220610172003-2.png"]]173 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/SW3L%20LoRaWAN%20Outdoor%20Flow%20Sensor/WebHome/image-20220519091423-2.png?width=723&height=258&rev=1.1||alt="image-20220519091423-2.png"]] 206 206 207 207 208 - [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDDS75%20-%20LoRaWAN%20Distance%20Detection%20Sensor%20User%20Manual/WebHome/image-20220610172003-2.png?rev=1.1||alt="image-20220610172003-2.png"]]176 +(% style="color:blue" %)**010: DW-010 Flow Sensor: diameter: G 1” / DN25. 64 pulse = 1 L** 209 209 178 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/SW3L%20LoRaWAN%20Outdoor%20Flow%20Sensor/WebHome/image-20220519091423-3.png?width=724&height=448&rev=1.1||alt="image-20220519091423-3.png"]] 210 210 211 -= 2. Configure DDS75-LB to connect to LoRaWAN network = 212 212 181 += 2. Configure SW3L-LB to connect to LoRaWAN network = 182 + 213 213 == 2.1 How it works == 214 214 215 215 216 -The DDS75-LB is configured as (% style="color:#037691" %)**LoRaWAN OTAA Class A**(%%) mode by default. It has OTAA keys to join LoRaWAN network. To connect a local LoRaWAN network, you need to input the OTAA keys in the LoRaWAN IoT server and press the button to activate theDDS75-LB. It will automatically join the network via OTAA and start to send the sensor value. The default uplink interval is 20 minutes.186 +The SW3L-LB is configured as (% style="color:#037691" %)**LoRaWAN OTAA Class A**(%%) mode by default. It has OTAA keys to join LoRaWAN network. To connect a local LoRaWAN network, you need to input the OTAA keys in the LoRaWAN IoT server and press the button to activate the SW3L-LB. It will automatically join the network via OTAA and start to send the sensor value. The default uplink interval is 20 minutes. 217 217 218 218 (% style="display:none" %) (%%) 219 219 ... ... @@ -227,9 +227,9 @@ 227 227 [[image:image-20230612171032-3.png||height="492" width="855"]](% style="display:none" %) 228 228 229 229 230 -(% style="color:blue" %)**Step 1:**(%%) Create a device in TTN with the OTAA keys from DDS75-LB.200 +(% style="color:blue" %)**Step 1:**(%%) Create a device in TTN with the OTAA keys from SW3L-LB. 231 231 232 -Each DDS75-LB is shipped with a sticker with the default device EUI as below:202 +Each SW3L-LB is shipped with a sticker with the default device EUI as below: 233 233 234 234 [[image:image-20230426084152-1.png||alt="图片-20230426084152-1.png" height="233" width="502"]] 235 235 ... ... @@ -258,10 +258,10 @@ 258 258 [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LSN50v2-S31-S31B%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20User%20Manual/WebHome/image-20220611161308-6.png?width=744&height=485&rev=1.1||alt="图片-20220611161308-6.png"]] 259 259 260 260 261 -(% style="color:blue" %)**Step 2:**(%%) Activate on DDS75-LB231 +(% style="color:blue" %)**Step 2:**(%%) Activate on SW3L-LB 262 262 263 263 264 -Press the button for 5 seconds to activate the DDS75-LB.234 +Press the button for 5 seconds to activate the SW3L-LB. 265 265 266 266 (% style="color:green" %)**Green led**(%%) will fast blink 5 times, device will enter (% style="color:blue" %)**OTA mode**(%%) for 3 seconds. And then start to JOIN LoRaWAN network. (% style="color:green" %)**Green led**(%%) will solidly turn on for 5 seconds after joined in network. 267 267 ... ... @@ -268,166 +268,355 @@ 268 268 After join success, it will start to upload messages to TTN and you can see the messages in the panel. 269 269 270 270 271 -== 2.3 241 +== 2.3 Uplink Payload == 272 272 243 +=== 2.3.1 Device Status, FPORT~=5 === 273 273 274 -((( 275 -DDS75-LB will uplink payload via LoRaWAN with below payload format: 276 -))) 277 277 278 -((( 279 -Uplink payload includes in total 8 bytes. 280 -))) 246 +Include device configure status. Once SW3L-LB Joined the network, it will uplink this message to the server. After that, SW3L-LB will uplink Device Status every 12 hours. 281 281 282 -(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:510px" %) 283 -|=(% style="width: 62.5px;background-color:#D9E2F3;color:#0070C0" %)((( 284 -**Size(bytes)** 285 -)))|=(% style="width: 62.5px;background-color:#D9E2F3;color:#0070C0" %)**2**|=(% style="background-color:#D9E2F3;color:#0070C0" %)**2**|=(% style="background-color:#D9E2F3;color:#0070C0" %)1|=(% style="background-color:#D9E2F3;color:#0070C0" %)2|=(% style="background-color:#D9E2F3;color:#0070C0" %)**1** 286 -|(% style="width:62.5px" %)**Value**|(% style="width:62.5px" %)[[BAT>>||anchor="H2.3.1A0BatteryInfo"]]|((( 287 -[[Distance>>||anchor="H2.3.2A0Distance"]] 288 -(unit: mm) 289 -)))|[[Digital Interrupt (Optional)>>||anchor="H2.3.3A0InterruptPin"]]|((( 290 -[[Temperature (Optional )>>||anchor="H2.3.4A0DS18B20Temperaturesensor"]] 291 -)))|[[Sensor Flag>>||anchor="H2.3.5A0SensorFlag"]] 248 +Users can use the downlink command(**0x26 01**) to ask SW3L-LB to send device configure detail, include device configure status. SW3L-LB will uplink a payload via FPort=5 to server. 292 292 293 - [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDDS75%20-%20LoRaWAN%20Distance%20Detection%20Sensor%20User%20Manual/WebHome/1654850511545-399.png?rev=1.1||alt="1654850511545-399.png"]]250 +The Payload format is as below. 294 294 295 295 296 -=== 2.3.1 Battery Info === 253 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %) 254 +|(% colspan="6" style="background-color:#d9e2f3; color:#0070c0" %)**Device Status (FPORT=5)** 255 +|(% style="width:103px" %)**Size (bytes)**|(% style="width:72px" %)**1**|**2**|(% style="width:91px" %)**1**|(% style="width:86px" %)**1**|(% style="width:44px" %)**2** 256 +|(% style="width:103px" %)**Value**|(% style="width:72px" %)Sensor Model|Firmware Version|(% style="width:91px" %)Frequency Band|(% style="width:86px" %)Sub-band|(% style="width:44px" %)BAT 297 297 258 +Example parse in TTNv3 298 298 299 - Check the battery voltageDDS75-LB.260 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/SW3L%20LoRaWAN%20Outdoor%20Flow%20Sensor/WebHome/1652925144491-755.png?width=732&height=139&rev=1.1||alt="1652925144491-755.png"]] 300 300 262 + 263 +(% style="color:#037691" %)**Sensor Model**(%%): For SW3L-LB, this value is 0x11 264 + 265 +(% style="color:#037691" %)**Firmware Version**(%%): 0x0100, Means: v1.0.0 version 266 + 267 +(% style="color:#037691" %)**Frequency Band**: 268 + 269 +*0x01: EU868 270 + 271 +*0x02: US915 272 + 273 +*0x03: IN865 274 + 275 +*0x04: AU915 276 + 277 +*0x05: KZ865 278 + 279 +*0x06: RU864 280 + 281 +*0x07: AS923 282 + 283 +*0x08: AS923-1 284 + 285 +*0x09: AS923-2 286 + 287 +*0x0a: AS923-3 288 + 289 +*0x0b: CN470 290 + 291 +*0x0c: EU433 292 + 293 +*0x0d: KR920 294 + 295 +*0x0e: MA869 296 + 297 + 298 +(% style="color:#037691" %)**Sub-Band**: 299 + 300 +AU915 and US915:value 0x00 ~~ 0x08 301 + 302 +CN470: value 0x0B ~~ 0x0C 303 + 304 +Other Bands: Always 0x00 305 + 306 + 307 +(% style="color:#037691" %)**Battery Info**: 308 + 309 +Check the battery voltage. 310 + 301 301 Ex1: 0x0B45 = 2885mV 302 302 303 303 Ex2: 0x0B49 = 2889mV 304 304 305 305 306 -=== 2.3.2 Distance===316 +=== 2.3.2 Sensor Configuration, FPORT~=4 === 307 307 308 308 319 +SW3L-LB will only send this command after getting the downlink command (0x26 02) from the server. 320 + 321 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:510px" %) 322 +|(% style="background-color:#d9e2f3; color:#0070c0; width:70px" %) **Size(bytes)**|(% style="background-color:#d9e2f3; color:#0070c0; width:105px" %)**3**|(% style="background-color:#d9e2f3; color:#0070c0; width:60px" %)**1**|(% style="background-color:#d9e2f3; color:#0070c0; width:96px" %)**1**|(% style="background-color:#d9e2f3; color:#0070c0; width:105px" %)**2**|(% style="background-color:#d9e2f3; color:#0070c0; width:74px" %)**1** 323 +|**Value**|(% style="width:104px" %)TDC(unit:sec)|(% style="width:43px" %)N/A|(% style="width:91px" %)Stop Timer|(% style="width:100px" %)Alarm Timer|(% style="width:69px" %)Reserve 324 + 325 +* (% style="color:#037691" %)**TDC: (default: 0x0004B0)** 326 + 327 +Uplink interval for the total pulse count, default value is 0x0004B0 which is 1200 seconds = 20 minutes. 328 + 329 + 330 +* (% style="color:#037691" %)**STOP Duration & Alarm Timer** 331 + 332 +Shows the configure value of [[Alarm for continuously water flow>>||anchor="H3.3.4Alarmforcontinuouslywaterflow"]] 333 + 334 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/SW3L%20LoRaWAN%20Outdoor%20Flow%20Sensor/WebHome/image-20220519095747-2.png?width=723&height=113&rev=1.1||alt="image-20220519095747-2.png"]] 335 + 336 + 337 +=== 2.3.3 Water Flow Value, Uplink FPORT~=2 === 338 + 339 + 309 309 ((( 310 - Getthe distance.Flat objectrange280mm-7500mm.341 +SW3L-LB will send this uplink **after** Device Status once join the LoRaWAN network successfully. And SW3L-LB will: 311 311 ))) 312 312 313 313 ((( 314 -For example, if the data you get from the register is 0x0B 0x05, the distance between the sensor and the measured object is(% style="color:#4472c4" %)** ** 345 +periodically send this uplink every 20 minutes, this interval [[can be changed>>||anchor="H3.3.1SetTransmitIntervalTime"]]. 346 +))) 315 315 316 -(% style="color:#4472c4" %)**0B05(H) = 2821 (D) = 2821 mm.** 348 +((( 349 +Uplink Payload totals 11 bytes. 317 317 ))) 318 318 352 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:510px" %) 353 +|=(% colspan="6" style="width: 510px;background-color:#D9E2F3;color:#0070C0" %)**Water Flow Value, FPORT=2** 354 +|(% style="width:60px" %)**Size(bytes)**|(% style="width:130px" %)**1**|(% style="width:130px" %)**4**|(% style="width:30px" %)**1**|(% style="width:50px" %)**1**|(% style="width:80px" %)**4** 355 +|(% style="width:110px" %)**Value**|(% style="width:81px" %)Calculate Flag & [[Alarm>>||anchor="H3.3.4Alarmforcontinuouslywaterflow"]]|(% style="width:95px" %)((( 356 +Total pulse Or Last Pulse 357 +)))|(% style="width:55px" %)MOD|(% style="width:115px" %)Reserve(0x01)|(% style="width:129px" %)[[Unix TimeStamp>>||anchor="H2.5.2UnixTimeStamp"]] 319 319 320 -* If the sensor value is 0x0000, it means system doesn't detect ultrasonic sensor. 321 -* If the sensor value lower than 0x0118 (280mm), the sensor value will be invalid. All value lower than 280mm will be set to 0x0014(20mm) which means the value is invalid. 359 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:470px" %) 360 +|=(% colspan="4" style="width: 470px;background-color:#D9E2F3;color:#0070C0" %)**Status & Alarm field** 361 +|(% style="width:60px" %)**Size(bit)**|(% style="width:80px" %)**6**|(% style="width:310px" %)**1**|(% style="width:20px" %)**1** 362 +|(% style="width:88px" %)**Value**|(% style="width:117px" %)Calculate Flag|(% style="width:221px" %)Alarm: 0: No Alarm; 1: Alarm|(% style="width:64px" %)N/A 322 322 323 - === 2.3.3 InterruptPin364 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/SW3L%20LoRaWAN%20Outdoor%20Flow%20Sensor/WebHome/image-20220519095946-3.png?width=736&height=284&rev=1.1||alt="image-20220519095946-3.png"]] 324 324 325 325 326 -This data field shows if this packet is generated by interrupt or not. [[Click here>>||anchor="H3.3.2SetInterruptMode"]] for the hardware and software set up. 367 +* ((( 368 +(% style="color:#037691" %)**Calculate Flag** 369 +))) 327 327 328 -**Example:** 371 +((( 372 +The calculate flag is a user defined field, IoT server can use this flag to handle different meters with different pulse factors. For example, if there are 100 Flow Sensors, meters 1 ~~50 are 1 liter/pulse and meters 51 ~~ 100 has 1.5 liter/pulse. 373 +))) 329 329 330 -0x00: Normal uplink packet. 375 +((( 376 +**Example: in the default payload:** 377 +))) 331 331 332 -0x01: Interrupt Uplink Packet. 379 +* ((( 380 +calculate flag=0: for SW3L-004 Flow Sensor: 450 pulse = 1 L 381 +))) 382 +* ((( 383 +calculate flag=1: for SW3L-006 Flow Sensor: 390 pulse = 1 L 384 +))) 385 +* ((( 386 +calculate flag=2: for SW3L-010 Flow Sensor: 64 pulse = 1 L 387 +))) 333 333 389 +((( 390 +Default value: 0. 391 +))) 334 334 335 -=== 2.3.4 DS18B20 Temperature sensor === 393 +((( 394 +Range (6 bits): (b)000000 ~~ (b) 111111 336 336 396 +If user use with a meter for example is 0.02L/pulse. To proper decode the correct value in server, 337 337 338 - Thisisoptional, user canconnectexternalDS18B20 sensorto the+3.3v, 1-wireandGNDpin . andthisfield will reporttemperature.398 +1) User can set the Calculate Flag of this sensor to 3. 339 339 340 -**Example**: 400 +2) In server side, when a sensor data arrive, the decoder will check the value of Calculate Flag, It the value is 3, the total volume = 0.02 x Pulse Count. 401 +))) 341 341 342 -If payload is: 0105H: (0105 & FC00 == 0), temp = 0105H /10 = 26.1 degree 403 +((( 404 +(% style="color:red" %)**NOTE: User need to set Calculate Flag to proper value before use Flow Sensor. Downlink or AT Command see: **(%%)Refer: [[Set Calculate Flag>>||anchor="H3.3.6Setthecalculateflag"]] 405 +))) 343 343 344 -If payload is: FF3FH : (FF3F & FC00 == 1) , temp = (FF3FH - 65536)/10 = -19.3 degrees. 407 +* ((( 408 +(% style="color:#037691" %)**Alarm** 409 +))) 345 345 411 +((( 412 +See [[Alarm for continuously water flow>>||anchor="H3.3.4Alarmforcontinuouslywaterflow"]] 413 +))) 346 346 347 - === 2.3.5 Sensor415 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/SW3L%20LoRaWAN%20Outdoor%20Flow%20Sensor/WebHome/image-20220519095946-4.png?width=724&height=65&rev=1.1||alt="image-20220519095946-4.png"]] 348 348 349 349 418 +* ((( 419 +(% style="color:#037691" %)**Total pulse** 420 +))) 421 + 350 350 ((( 351 - 0x01: DetectUltrasonic Sensor423 +Total pulse/counting since factory 352 352 ))) 353 353 354 354 ((( 355 -0x00 :NoUltrasonic Sensor427 +Range (4 Bytes) : 0x00000000~~ 0xFFFFFFFF . 356 356 ))) 357 357 430 +* ((( 431 +(% style="color:#037691" %)**Last Pulse** 432 +))) 358 358 359 -=== 2.3.6 Decode payload in The Things Network === 434 +((( 435 +Total pulse since last FPORT=2 uplink. (Default 20 minutes) 436 +))) 360 360 438 +((( 439 +Range (4 Bytes) : 0x00000000~~ 0xFFFFFFFF . 440 +))) 361 361 362 -While using TTN network, you can add the payload format to decode the payload. 442 +* ((( 443 +(% style="color:#037691" %)**MOD: Default =0** 444 +))) 363 363 364 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDDS75%20-%20LoRaWAN%20Distance%20Detection%20Sensor%20User%20Manual/WebHome/1654850829385-439.png?rev=1.1||alt="1654850829385-439.png"]] 446 +((( 447 +MOD=0 ~-~-> Uplink Total Pulse since factory 448 +))) 365 365 366 -The payload decoder function for TTN V3 is here: 450 +((( 451 +MOD=1 ~-~-> Uplink total pulse since last FPORT=2 uplink. 452 +))) 367 367 454 +* ((( 455 +(% style="color:#037691" %)**Water Flow Value** 456 +))) 457 + 368 368 ((( 369 - DDS75-LBTTNV3 PayloadDecoder: [[ttps:~~/~~/github.com/dragino/dragino-end-node-decoder>>https://github.com/dragino/dragino-end-node-decoder]]459 +**Total Water Flow Volume = (Calculate Flag) x (Total Pulse)=9597/450=21.3L** 370 370 ))) 371 371 462 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/SW3L%20LoRaWAN%20Outdoor%20Flow%20Sensor/WebHome/image-20220519095946-5.png?width=727&height=50&rev=1.1||alt="image-20220519095946-5.png"]] 372 372 373 -== 2.4 Uplink Interval == 374 374 465 +((( 466 +**Total Water Flow for TDC timer = (Calculate Flag) x (Last Pulse)=79/450=0.2L** 467 +))) 375 375 376 - The DDS75-LB by defaultuplinkthe sensordata every 20 minutes.Usercanchange this intervalby AT CommandrLoRaWANDownlink Command.Seethis link: [[ChangeUplink Interval>>||anchor="H3.3.1SetTransmitIntervalTime"]]469 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/SW3L%20LoRaWAN%20Outdoor%20Flow%20Sensor/WebHome/image-20220519095946-6.png?width=733&height=43&rev=1.1||alt="image-20220519095946-6.png"]] ** ** 377 377 378 378 379 -== 2. 5Show Datain DataCakeIoTServer==472 +=== 2.3.4 Historical Water Flow Status, FPORT~=3 === 380 380 381 381 382 382 ((( 383 - [[DATACAKE>>url:https://datacake.co/]] provides ahumanfriendly interface to show thensordata, oncewe have datain TTN, we canuse [[DATACAKE>>url:https://datacake.co/]] to connecttoTTNandsee the datain DATACAKE. Belowarethe steps:476 +SW3L-LB stores sensor values and users can retrieve these history values via the [[downlink command>>||anchor="H2.5DatalogFeature"]]. 384 384 ))) 385 385 479 +((( 480 +The historical payload includes one or multiplies entries and every entry has the same payload as Real-Time water flow status. 481 +))) 386 386 483 +* ((( 484 +Each data entry is 11 bytes and has the same structure as [[real time water flow status>>||anchor="H2.3.3A0WaterFlowValue2CUplinkFPORT3D2"]], to save airtime and battery, SW3L will send max bytes according to the current DR and Frequency bands. 485 +))) 486 + 387 387 ((( 388 - (% style="color:blue"%)**Step1**(%%)**: Besurethat your deviceisprogrammed andproperlyconnectedtothenetworkatthistime.**488 +For example, in the US915 band, the max payload for different DR is: 389 389 ))) 390 390 391 391 ((( 392 -(% style="color:blue" %)** Step2**(%%)**:ToconfiguretheApplicationtoforward data to DATACAKE you willneedto add integration.Toadd the DATACAKE integration, perform the following steps:**492 +(% style="color:blue" %)**a) DR0:**(%%) max is 11 bytes so one entry of data 393 393 ))) 394 394 495 +((( 496 +(% style="color:blue" %)**b) DR1:**(%%) max is 53 bytes so devices will upload 4 entries of data (total 44 bytes) 497 +))) 395 395 396 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDDS75%20-%20LoRaWAN%20Distance%20Detection%20Sensor%20User%20Manual/WebHome/1654592790040-760.png?rev=1.1||alt="1654592790040-760.png"]] 499 +((( 500 +(% style="color:blue" %)**c) DR2:**(%%) total payload includes 11 entries of data 501 +))) 397 397 503 +((( 504 +(% style="color:blue" %)**d) DR3:**(%%) total payload includes 22 entries of data. 505 +))) 398 398 399 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDDS75%20-%20LoRaWAN%20Distance%20Detection%20Sensor%20User%20Manual/WebHome/1654592800389-571.png?rev=1.1||alt="1654592800389-571.png"]] 507 +((( 508 +If SW3L-LB doesn't have any data in the polling time. It will uplink 11 bytes of 0 509 +))) 400 400 511 +((( 512 +(% style="color:#037691" %)**Downlink:** 513 +))) 401 401 402 -(% style="color:blue" %)**Step 3**(%%)**: Create an account or log in Datacake.** 515 +((( 516 +0x31 62 46 B1 F0 62 46 B3 94 07 517 +))) 403 403 404 - (% style="color:blue"%)**Step 4**(%%)**:Search theDDS75-LB andadd DevEUI.**519 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/SW3L%20LoRaWAN%20Outdoor%20Flow%20Sensor/WebHome/1652926690850-712.png?width=726&height=115&rev=1.1||alt="1652926690850-712.png"]] 405 405 406 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDDS75%20-%20LoRaWAN%20Distance%20Detection%20Sensor%20User%20Manual/WebHome/1654851029373-510.png?rev=1.1||alt="1654851029373-510.png"]] 407 407 522 +((( 523 +(% style="color:#037691" %)**Uplink:** 524 +))) 408 408 409 -After added, the sensor data arrive TTN V3, it will also arrive and show in Datacake. 526 +((( 527 +00 00 01 00 00 00 00 62 46 B2 26 00 00 01 00 00 00 00 62 46 B2 5D 00 00 01 00 00 00 00 62 46 B2 99 00 00 01 00 00 00 00 62 46 B2 D5 00 00 01 00 00 01 15 62 46 B3 11 00 00 01 00 00 01 1F 62 46 B3 7E 528 +))) 410 410 411 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDDS75%20-%20LoRaWAN%20Distance%20Detection%20Sensor%20User%20Manual/WebHome/image-20220610165129-11.png?width=1088&height=595&rev=1.1||alt="image-20220610165129-11.png"]] 530 +((( 531 +(% style="color:#037691" %)**Parsed Value:** 532 +))) 412 412 534 +((( 535 +[Alarm, Calculate Flag, MOD, Total pulse or Last Pulse,** **Water Flow Value, TIME] 536 +))) 413 413 414 414 415 -== 2.6 Datalog Feature == 539 +((( 540 +[FALSE,0,0,0,0.0,2022-04-01 08:04:54], 541 +))) 416 416 543 +((( 544 +[FALSE,0,0,0,0.0,2022-04-01 08:05:49], 545 +))) 417 417 418 -Datalog Feature is to ensure IoT Server can get all sampling data from Sensor even if the LoRaWAN network is down. For each sampling, DDS75-LB will store the reading for future retrieving purposes. 547 +((( 548 +[FALSE,0,0,0,0.0,2022-04-01 08:06:49], 549 +))) 419 419 551 +((( 552 +[FALSE,0,0,0,0.0,2022-04-01 08:07:49], 553 +))) 420 420 421 -=== 2.6.1 Ways to get datalog via LoRaWAN === 555 +((( 556 +[FALSE,0,0,277,0.6,2022-04-01 08:08:49], 557 +))) 422 422 559 +((( 560 +[FALSE,0,0,287,0.6,2022-04-01 08:10:38], 561 +))) 423 423 424 - SetPNACKMD=1, DDS75-LBwill wait for ACK for every uplink,whenthereisetwork,DDS75-LB will markthese records with non-ack messages andstorethesensor data, and itwill sendall messages (10sinterval) after the network recovery.563 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/SW3L%20LoRaWAN%20Outdoor%20Flow%20Sensor/WebHome/1652926777796-267.png?width=724&height=279&rev=1.1||alt="1652926777796-267.png"]] 425 425 565 + 566 +== 2.4 Payload Decoder file == 567 + 568 + 569 +In TTN, use can add a custom payload so it shows friendly reading 570 + 571 +In the page (% style="color:#037691" %)**Applications ~-~-> Payload Formats ~-~-> Custom ~-~-> decoder**(%%) to add the decoder from: [[https:~~/~~/github.com/dragino/dragino-end-node-decoder>>https://github.com/dragino/dragino-end-node-decoder]] 572 + 573 + 574 +== 2.5 Datalog Feature == 575 + 576 + 577 +Datalog Feature is to ensure IoT Server can get all sampling data from Sensor even if the LoRaWAN network is down. For each sampling, SW3L-LB will store the reading for future retrieving purposes. 578 + 579 + 580 +=== 2.5.1 Ways to get datalog via LoRaWAN === 581 + 582 + 583 +Set PNACKMD=1, SW3L-LB will wait for ACK for every uplink, when there is no LoRaWAN network,SW3L-LB will mark these records with non-ack messages and store the sensor data, and it will send all messages (10s interval) after the network recovery. 584 + 426 426 * ((( 427 -a) DDS75-LB will do an ACK check for data records sending to make sure every data arrive server.586 +a) SW3L-LB will do an ACK check for data records sending to make sure every data arrive server. 428 428 ))) 429 429 * ((( 430 -b) DDS75-LB will send data in **CONFIRMED Mode** when PNACKMD=1, butDDS75-LB won't re-transmit the packet if it doesn't get ACK, it will just mark it as a NONE-ACK message. In a future uplink ifDDS75-LB gets a ACK,DDS75-LB will consider there is a network connection and resend all NONE-ACK messages.589 +b) SW3L-LB will send data in **CONFIRMED Mode** when PNACKMD=1, but SW3L-LB won't re-transmit the packet if it doesn't get ACK, it will just mark it as a NONE-ACK message. In a future uplink if SW3L-LB gets a ACK, SW3L-LB will consider there is a network connection and resend all NONE-ACK messages. 431 431 ))) 432 432 433 433 Below is the typical case for the auto-update datalog feature (Set PNACKMD=1) ... ... @@ -435,10 +435,10 @@ 435 435 [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/WebHome/image-20220703111700-2.png?width=1119&height=381&rev=1.1||alt="图片-20220703111700-2.png" height="381" width="1119"]] 436 436 437 437 438 -=== 2. 6.2 Unix TimeStamp ===597 +=== 2.5.2 Unix TimeStamp === 439 439 440 440 441 - DDS75-LB uses Unix TimeStamp format based on600 +SW3L-LB uses Unix TimeStamp format based on 442 442 443 443 [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/WebHome/image-20220523001219-11.png?width=627&height=97&rev=1.1||alt="图片-20220523001219-11.png" height="97" width="627"]] 444 444 ... ... @@ -452,17 +452,17 @@ 452 452 So, we can use AT+TIMESTAMP=1611889405 or downlink 3060137afd00 to set the current time 2021 – Jan ~-~- 29 Friday 03:03:25 453 453 454 454 455 -=== 2. 6.3 Set Device Time ===614 +=== 2.5.3 Set Device Time === 456 456 457 457 458 458 User need to set (% style="color:blue" %)**SYNCMOD=1**(%%) to enable sync time via MAC command. 459 459 460 -Once DDS75-LB Joined LoRaWAN network, it will send the MAC command (DeviceTimeReq) and the server will reply with (DeviceTimeAns) to send the current time toDDS75-LB. IfDDS75-LB fails to get the time from the server,DDS75-LB will use the internal time and wait for next time request (AT+SYNCTDC to set the time request period, default is 10 days).619 +Once SW3L-LB Joined LoRaWAN network, it will send the MAC command (DeviceTimeReq) and the server will reply with (DeviceTimeAns) to send the current time to SW3L-LB. If SW3L-LB fails to get the time from the server, SW3L-LB will use the internal time and wait for next time request (AT+SYNCTDC to set the time request period, default is 10 days). 461 461 462 462 (% style="color:red" %)**Note: LoRaWAN Server need to support LoRaWAN v1.0.3(MAC v1.0.3) or higher to support this MAC command feature, Chirpstack,TTN V3 v3 and loriot support but TTN V3 v2 doesn't support. If server doesn't support this command, it will through away uplink packet with this command, so user will lose the packet with time request for TTN V3 v2 if SYNCMOD=1.** 463 463 464 464 465 -=== 2. 6.4 Poll sensor value ===624 +=== 2.5.4 Poll sensor value === 466 466 467 467 468 468 Users can poll sensor values based on timestamps. Below is the downlink command. ... ... @@ -485,24 +485,24 @@ 485 485 ))) 486 486 487 487 ((( 488 -Uplink Internal =5s,means DDS75-LB will send one packet every 5s. range 5~~255s.647 +Uplink Internal =5s,means SW3L-LB will send one packet every 5s. range 5~~255s. 489 489 ))) 490 490 491 491 492 -== 2. 7Frequency Plans ==651 +== 2.6 Frequency Plans == 493 493 494 494 495 -The DDS75-LB uses OTAA mode and below frequency plans by default. If user want to use it with different frequency plan, please refer the AT command sets.654 +The SW3L-LB uses OTAA mode and below frequency plans by default. If user want to use it with different frequency plan, please refer the AT command sets. 496 496 497 497 [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20Frequency%20Band/>>http://wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20Frequency%20Band/]] 498 498 499 499 500 -= 3. Configure DDS75-LB =659 += 3. Configure SW3L-LB = 501 501 502 502 == 3.1 Configure Methods == 503 503 504 504 505 - DDS75-LB supports below configure method:664 +SW3L-LB supports below configure method: 506 506 507 507 * AT Command via Bluetooth Connection (**Recommended**): [[BLE Configure Instruction>>http://wiki.dragino.com/xwiki/bin/view/Main/BLE%20Bluetooth%20Remote%20Configure/]]. 508 508 ... ... @@ -510,6 +510,7 @@ 510 510 511 511 * LoRaWAN Downlink. Instruction for different platforms: See [[IoT LoRaWAN Server>>http://wiki.dragino.com/xwiki/bin/view/Main/]] section. 512 512 672 + 513 513 == 3.2 General Commands == 514 514 515 515 ... ... @@ -524,10 +524,10 @@ 524 524 [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/>>http://wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/]] 525 525 526 526 527 -== 3.3 Commands special design for DDS75-LB ==687 +== 3.3 Commands special design for SW3L-LB == 528 528 529 529 530 -These commands only valid for DDS75-LB, as below:690 +These commands only valid for SW3L-LB, as below: 531 531 532 532 533 533 === 3.3.1 Set Transmit Interval Time === ... ... @@ -572,9 +572,169 @@ 572 572 Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds 573 573 ))) 574 574 575 -=== 3.3.2 Set Interrupt Mode === 576 576 736 +=== 3.3.2 Quit AT Command === 577 577 738 + 739 +Feature: Quit AT Command mode, so user needs to input the password again before using AT Commands. 740 + 741 +(% style="color:blue" %)**AT Command: AT+DISAT** 742 + 743 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:452px" %) 744 +|=(% style="width: 155px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 198px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 99px;background-color:#D9E2F3;color:#0070C0" %)**Response** 745 +|(% style="width:155px" %)AT+DISAT|(% style="width:198px" %)Quit AT Commands mode|(% style="width:96px" %)OK 746 + 747 +(% style="color:blue" %)**Downlink Command:** 748 + 749 +No downlink command for this feature. 750 + 751 + 752 +=== 3.3.3 Get Device Status === 753 + 754 + 755 +Send a LoRaWAN downlink to ask device send Alarm settings. 756 + 757 +(% style="color:blue" %)**Downlink Payload: **(%%)0x26 01 758 + 759 +Sensor will upload Device Status via FPORT=5. See payload section for detail. 760 + 761 + 762 +=== 3.3.4 Alarm for continuously water flow === 763 + 764 + 765 +((( 766 +This feature is to monitor and send Alarm for continuously water flow. 767 +))) 768 + 769 +((( 770 +Example case is for Toilet water monitoring, if some one push toilet button, the toilet will have water flow. If the toilet button has broken and can't returned to original state, the water flow will keep for hours or days which cause huge waste for water. 771 +))) 772 + 773 +((( 774 +To monitor this faulty and send alarm, there are two settings: 775 +))) 776 + 777 +* ((( 778 +(% style="color:#4f81bd" %)**Stop Duration: Unit: Second** 779 +))) 780 + 781 +((( 782 +Default: 15s, If SW3L-LB didn't see any water flow in 15s, SW3L-LB will consider stop of water flow event. 783 +))) 784 + 785 +* ((( 786 +(% style="color:#4f81bd" %)**Alarm Timer: Units: Minute; Default 0 minutes (means Alarm disable)** 787 +))) 788 + 789 +((( 790 +**Example:** 3 minutes, if SW3L-LB detect a start of water flow event and didn't detect a stop event within Alarm timer, SW3L-LB will send an Alarm to indicate a water flow abnormal alarm. 791 +))) 792 + 793 +((( 794 +So for example, If we set stop duration=15s and Alarm Timer=3minutes. If the toilet water flow continuously for more than 3 minutes, Sensor will send an alarm (in Confirmed MODE) to platform. 795 +))) 796 + 797 +((( 798 +(% style="color:red" %)**Note:** **After this alarm is send, sensor will consider a stop of water flow and count for another new event. So if water flow waste last for 1 hour, Sensor will keep sending alarm every 3 minutes.** 799 +))) 800 + 801 +((( 802 +(% style="color:#4f81bd" %)**AT Command**(%%) to configure: 803 +))) 804 + 805 +* ((( 806 +AT+PTRIG=15,3 ~-~-> Set Stop duration: 15s, Alarm Timer: 3 minutes. 807 +))) 808 + 809 +* ((( 810 +AT+ PTRIG=15,0 ~-~-> Default Value, disable water waste Alarm. 811 +))) 812 + 813 +((( 814 +(% style="color:#4f81bd" %)**Downlink Command**(%%) to configure: 815 +))) 816 + 817 +((( 818 +Command: **0xAA aa bb cc** 819 +))) 820 + 821 +((( 822 +AA: Command Type Code 823 +))) 824 + 825 +((( 826 +aa: Stop duration 827 +))) 828 + 829 +((( 830 +bb cc: Alarm Timer 831 +))) 832 + 833 +((( 834 +If user send 0xAA 0F 00 03: equal to AT+PTRIG=15,3 835 +))) 836 + 837 + 838 +=== 3.3.5 Clear Flash Record === 839 + 840 + 841 +Feature: Clear flash storage for data log feature. 842 + 843 +(% style="color:blue" %)**AT Command: AT+CLRDTA** 844 + 845 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:500px" %) 846 +|=(% style="width: 157px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 169px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 174px;background-color:#D9E2F3;color:#0070C0" %)**Response** 847 +|(% style="width:157px" %)AT+CLRDTA|(% style="width:169px" %)Clear flash storage for data log feature.|Clear all stored sensor data… OK 848 + 849 +((( 850 +(% style="color:blue" %)**Downlink Command:** 851 +))) 852 + 853 +((( 854 +* **Example**: 0xA301 ~/~/ Same as AT+CLRDTA 855 +))) 856 + 857 + 858 + 859 +=== 3.3.6 Set the calculate flag === 860 + 861 + 862 +Feature: Set the calculate flag 863 + 864 +(% style="color:blue" %)**AT Command: AT+CALCFLAG** 865 + 866 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:461px" %) 867 +|=(% style="width: 158px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 193px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 110px;background-color:#D9E2F3;color:#0070C0" %)**Response** 868 +|(% style="width:158px" %)AT+CALCFLAG =1|(% style="width:192px" %)Set the calculate flag to 1.|(% style="width:109px" %)OK 869 +|(% style="width:158px" %)AT+CALCFLAG =2|(% style="width:192px" %)Set the calculate flag to 2.|(% style="width:109px" %)OK 870 + 871 +(% style="color:blue" %)**Downlink Command:** 872 + 873 +* **Example**: 0XA501 ~/~/ Same as AT+CALCFLAG =1 874 + 875 + 876 +=== 3.3.7 Set count number === 877 + 878 + 879 +Feature: Manually set the count number 880 + 881 +(% style="color:blue" %)**AT Command: AT+SETCNT** 882 + 883 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:479px" %) 884 +|=(% style="width: 160px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 223px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 96px;background-color:#D9E2F3;color:#0070C0" %)**Response** 885 +|(% style="width:160px" %)AT+ SETCNT =0|(% style="width:221px" %)Set the count number to 0.|(% style="width:95px" %)OK 886 +|(% style="width:160px" %)AT+ SETCNT =100|(% style="width:221px" %)Set the count number to 100.|(% style="width:95px" %)OK 887 + 888 +(% style="color:blue" %)**Downlink Command:** 889 + 890 +* **Example**: 0xA6000001 ~/~/ Same as AT+ SETCNT =1 891 + 892 +* **Example**: 0xA6000064 ~/~/ Same as AT+ SETCNT =100 893 + 894 + 895 +=== 3.3.8 Set Interrupt Mode === 896 + 897 + 578 578 Feature, Set Interrupt mode for PA8 of pin. 579 579 580 580 When AT+INTMOD=0 is set, PA8 is used as a digital input port. ... ... @@ -606,122 +606,124 @@ 606 606 607 607 * Example 2: Downlink Payload: 06000003 ~/~/ Set the interrupt mode to rising edge trigger 608 608 609 -= 4. Battery & Power Consumption = 610 610 930 +=== 3.3.9 Set work mode === 611 611 612 -DDS75-LB use ER26500 + SPC1520 battery pack. See below link for detail information about the battery info and how to replace. 613 613 614 - [[**Battery Info & PowerConsumption Analyze**>>http://wiki.dragino.com/xwiki/bin/view/Main/How%20to%20calculate%20the%20battery%20life%20of%20Dragino%20sensors%3F/]] .933 +Feature: Manually set the work mode 615 615 616 616 617 -= 5. OTAFirmware update=936 +(% style="color:blue" %)**AT Command: AT+MOD** 618 618 938 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:463px" %) 939 +|=(% style="width: 162px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 193px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 108px;background-color:#D9E2F3;color:#0070C0" %)**Response** 940 +|(% style="width:162px" %)AT+MOD=0|(% style="width:191px" %)Set the work mode to 0.|(% style="width:106px" %)OK 941 +|(% style="width:162px" %)AT+MOD=1|(% style="width:191px" %)Set the work mode to 1|(% style="width:106px" %)OK 619 619 620 -(% class="wikigeneratedid" %) 621 -User can change firmware DDS75-LB to: 943 +(% style="color:blue" %)**Downlink Command:** 622 622 623 -* ChangeFrequencyband/region.945 +* **Example: **0x0A00 ~/~/ Same as AT+MOD=0 624 624 625 -* Updatewithnewfeatures.947 +* **Example:** 0x0A01 ~/~/ Same as AT+MOD=1 626 626 627 -* Fix bugs. 628 628 629 - Firmwareandchangelogcanbe downloaded from: **[[Firmware download link>>url:https://www.dropbox.com/sh/7la95mae0fn03xe/AACtzs-32m22TLb75B-iIr-Qa?dl=0]]**950 += 4. Battery & Power Consumption = 630 630 631 -Methods to Update Firmware: 632 632 633 - *(Recommandedway)OTAfirmwareupdateviawireless: [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/Firmware%20OTA%20Update%20for%20Sensors/>>url:http://wiki.dragino.com/xwiki/bin/view/Main/Firmware%20OTA%20Update%20for%20Sensors/]]953 +SW3L-LB use ER26500 + SPC1520 battery pack. See below link for detail information about the battery info and how to replace. 634 634 635 -* UpdatethroughUARTTTL interface: **[[Instruction>>url:http://wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H1.LoRaSTv4baseHardware]]**.955 +[[**Battery Info & Power Consumption Analyze**>>http://wiki.dragino.com/xwiki/bin/view/Main/How%20to%20calculate%20the%20battery%20life%20of%20Dragino%20sensors%3F/]] . 636 636 637 -= 6. FAQ = 638 638 639 -= =6.1Whatis the frequencyplanfor DDS75-LB?==958 += 5. OTA Firmware update = 640 640 641 641 642 -DDS75-LB use the same frequency as other Dragino products. User can see the detail from this link: [[Introduction>>doc:Main.End Device Frequency Band.WebHome||anchor="H1.Introduction"]] 961 +(% class="wikigeneratedid" %) 962 +User can change firmware SW3L-LB to: 643 643 964 +* Change Frequency band/ region. 644 644 645 - ==6.2 Can I useDDS75-LBincondensationenvironment? ==966 +* Update with new features. 646 646 968 +* Fix bugs. 647 647 648 - DDS75-LBisnotsuitableto beusedin condensationenvironment.Condensationnthe DDS75-LBprobewillaffect thereading and always got0.970 +Firmware and changelog can be downloaded from : **[[Firmware download link>>url:https://www.dropbox.com/sh/kwqv57tp6pejias/AAAopYMATh1GM6fZ-VRCLrpDa?dl=0]]** 649 649 972 +Methods to Update Firmware: 650 650 651 - =7.TroubleShooting=974 +* (Recommanded way) OTA firmware update via wireless: [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/Firmware%20OTA%20Update%20for%20Sensors/>>url:http://wiki.dragino.com/xwiki/bin/view/Main/Firmware%20OTA%20Update%20for%20Sensors/]] 652 652 653 - ==7.1WhyIcan'tjoinTTN V3in915/AU915bands? ==976 +* Update through UART TTL interface. **[[Instruction>>url:http://wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H1.LoRaSTv4baseHardware]]**. 654 654 655 655 656 - Itis due to channel mapping.Please see below link: [[Frequency band>>doc:Main.LoRaWANCommunication Debug.WebHome||anchor="H2.NoticeofUS9152FCN4702FAU915Frequencyband"]]979 += 6. FAQ = 657 657 981 +== 6.1 AT Commands input doesn't work == 658 658 659 -== 7.2 AT Command input doesn't work == 660 660 984 +In the case if user can see the console output but can't type input to the device. Please check if you already include the (% style="color:green" %)**ENTER**(%%) while sending out the command. Some serial tool doesn't send (% style="color:green" %)**ENTER**(%%) while press the send key, user need to add ENTER in their string. 661 661 662 -In the case if user can see the console output but can't type input to the device. Please check if you already include the (% style="color:blue" %)**ENTER**(%%) while sending out the command. Some serial tool doesn't send (% style="color:blue" %)**ENTER**(%%) while press the send key, user need to add ENTER in their string. 663 663 987 += 7. Order Info = 664 664 665 -== 7.3 Why does the sensor reading show 0 or "No sensor" == 666 666 990 +Part Number: (% style="color:blue" %)**SW3L-LB-XXX-YYY** 667 667 668 - ~1.The measurementobject is very closetothesensor, but in the blind spotofthesensor.992 +(% style="color:red" %)**XXX**(%%): The default frequency band 669 669 670 - 2.Sensorwiringisdisconnected994 +* (% style="color:red" %)**AS923**(%%): LoRaWAN AS923 band 671 671 672 - 3.Notusingthectdecoder996 +* (% style="color:red" %)**AU915**(%%): LoRaWAN AU915 band 673 673 998 +* (% style="color:red" %)**EU433**(%%): LoRaWAN EU433 band 674 674 675 - ==7.4Abnormal readingsThe gap between multiplereadings is toolargeorthe gap between thereadingsandtheactualvalueis too large ==1000 +* (% style="color:red" %)**EU868**(%%): LoRaWAN EU868 band 676 676 1002 +* (% style="color:red" %)**KR920**(%%): LoRaWAN KR920 band 677 677 678 - 1)Pleasecheck ifthere is somethingon the probe affecting its measurement(condensedwater, volatileoil,etc.)1004 +* (% style="color:red" %)**US915**(%%): LoRaWAN US915 band 679 679 680 - 2)Doesitchangewith temperature,temperaturewillaffectitsmeasurement1006 +* (% style="color:red" %)**IN865**(%%): LoRaWAN IN865 band 681 681 682 - 3)Ifabnormal data occurs, you canturn on DEBUG mode, Please use downlinkorATCOMMANtoenterDEBUG mode.1008 +* (% style="color:red" %)**CN470**(%%): LoRaWAN CN470 band 683 683 684 -downlink command: (% style="color:blue" %)**F1 01**(%%), AT command: (% style="color:blue" %)**AT+DDEBUG=1** 1010 +((( 1011 +(% style="color:blue" %)**YYY**(%%): Flow Sensor Model: 1012 +))) 685 685 686 -4) After entering the debug mode, it will send 20 pieces of data at a time, and you can send its uplink to us for analysis 1014 +((( 1015 + **004:** DW-004 Flow Sensor: diameter: G1/2” / DN15. 450 pulse = 1 L 1016 +))) 687 687 688 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDDS75%20-%20LoRaWAN%20Distance%20Detection%20Sensor%20User%20Manual/WebHome/image-20230113135125-2.png?width=1057&height=136&rev=1.1||alt="image-20230113135125-2.png"]] 1018 +((( 1019 + **006:** DW-006 Flow Sensor: diameter: G3/4” / DN20. 390 pulse = 1 L 1020 +))) 689 689 1022 +((( 1023 + **010:** DW-010 Flow Sensor: diameter: G 1” / DN25. 64 pulse = 1 L 1024 +))) 690 690 691 -Its original payload will be longer than other data. Even though it is being parsed, it can be seen that it is abnormal data. 1026 +* ((( 1027 +calculate flag=0: for SW3L-004 Flow Sensor: 450 pulse = 1 L 1028 +))) 692 692 693 -Please send the data to us for check. 1030 +* ((( 1031 +calculate flag=1: for SW3L-006 Flow Sensor: 390 pulse = 1 L 1032 +))) 694 694 1034 +* ((( 1035 +calculate flag=2: for SW3L-010 Flow Sensor: 64 pulse = 1 L 695 695 696 -= 8. Order Info = 697 697 1038 + 1039 +))) 698 698 699 - PartNumber: (%style="color:blue"%)**DDS75-LB-XXX**1041 += 8. Packing Info = 700 700 701 -(% style="color:red" %)**XXX**(%%): **The default frequency band** 702 702 703 -* (% style="color:red" %)**AS923**(%%): LoRaWAN AS923 band 704 - 705 -* (% style="color:red" %)**AU915**(%%): LoRaWAN AU915 band 706 - 707 -* (% style="color:red" %)**EU433**(%%): LoRaWAN EU433 band 708 - 709 -* (% style="color:red" %)**EU868**(%%): LoRaWAN EU868 band 710 - 711 -* (% style="color:red" %)**KR920**(%%): LoRaWAN KR920 band 712 - 713 -* (% style="color:red" %)**US915**(%%): LoRaWAN US915 band 714 - 715 -* (% style="color:red" %)**IN865**(%%): LoRaWAN IN865 band 716 - 717 -* (% style="color:red" %)**CN470**(%%): LoRaWAN CN470 band 718 - 719 -= 9. Packing Info = 720 - 721 - 722 722 (% style="color:#037691" %)**Package Includes**: 723 723 724 -* DDS75-LB LoRaWANDistance DetectionSensorx 11046 +* SW3L-LB LoRaWAN Flow Sensor 725 725 726 726 (% style="color:#037691" %)**Dimension and weight**: 727 727 ... ... @@ -733,9 +733,10 @@ 733 733 734 734 * Weight / pcs : g 735 735 736 -= 10. Support = 737 737 1059 += 9. Support = 738 738 1061 + 739 739 * Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule. 740 740 741 741 * Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[Support@dragino.cc>>mailto:Support@dragino.cc]].