Changes for page DS20L -- LoRaWAN Smart Distance Detector User Manual 01
Last modified by Mengting Qiu on 2023/12/14 11:15
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -22,13 +22,13 @@ 22 22 23 23 It detects the distance(% style="color:blue" %)** between the measured object and the sensor**(%%), and uploads the value via wireless to LoRaWAN IoT Server. 24 24 25 -The LoRa wireless technology used in DDS75-LB allows device to send data and reach extremely long ranges at low data-rates. It provides ultra-long range spread spectrum communication and high interference immunity whilst minimizing current consumption.25 +The LoRa wireless technology used in SW3L-LB allows device to send data and reach extremely long ranges at low data-rates. It provides ultra-long range spread spectrum communication and high interference immunity whilst minimizing current consumption. 26 26 27 - DDS75-LB (% style="color:blue" %)**supports BLE configure**(%%) and (% style="color:blue" %)**wireless OTA update**(%%) which make user easy to use.27 +SW3L-LB (% style="color:blue" %)**supports BLE configure**(%%) and (% style="color:blue" %)**wireless OTA update**(%%) which make user easy to use. 28 28 29 - DDS75-LB is powered by (% style="color:blue" %)**8500mAh Li-SOCI2 battery**(%%), it is designed for long term use up to 5 years.29 +SW3L-LB is powered by (% style="color:blue" %)**8500mAh Li-SOCI2 battery**(%%), it is designed for long term use up to 5 years. 30 30 31 -Each DDS75-LB is pre-load with a set of unique keys for LoRaWAN registrations, register these keys to local LoRaWAN server and it will auto connect after power on.31 +Each SW3L-LB is pre-load with a set of unique keys for LoRaWAN registrations, register these keys to local LoRaWAN server and it will auto connect after power on. 32 32 33 33 [[image:image-20230612170943-2.png||height="525" width="912"]] 34 34 ... ... @@ -73,9 +73,9 @@ 73 73 )))|(% style="width:66px" %)65%|(% style="width:90px" %)80%|(% style="width:48px" %)RH|(% style="width:203px" %)(1) 74 74 75 75 ((( 76 - (% style="color:red" %)**Remarks: (1) a. When the ambient temperature is 0-39 ℃, the maximum humidity is 90% (non-condensing); **76 +**Remarks: (1) a. When the ambient temperature is 0-39 ℃, the maximum humidity is 90% (non-condensing); ** 77 77 78 - (% style="color:red" %)** b. When the ambient temperature is 40-50 ℃, the highest humidity is the highest humidity in the natural world at the current temperature (no condensation)**78 +**~ b. When the ambient temperature is 40-50 ℃, the highest humidity is the highest humidity in the natural world at the current temperature (no condensation)** 79 79 80 80 81 81 ))) ... ... @@ -105,15 +105,16 @@ 105 105 * Sleep Mode: 5uA @ 3.3v 106 106 * LoRa Transmit Mode: 125mA @ 20dBm, 82mA @ 14dBm 107 107 108 + 108 108 == 1.4 Effective measurement range Reference beam pattern == 109 109 110 110 111 - (% style="color:blue" %)**1. The tested object is a white cylindrical tube made of PVC, with a height of 100cm and a diameter of 7.5cm.**112 +**~1. The tested object is a white cylindrical tube made of PVC, with a height of 100cm and a diameter of 7.5cm.** 112 112 113 113 [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDDS75%20-%20LoRaWAN%20Distance%20Detection%20Sensor%20User%20Manual/WebHome/1654852253176-749.png?rev=1.1||alt="1654852253176-749.png"]] 114 114 115 115 116 - (% style="color:blue" %)**2. The object to be tested is a "corrugated cardboard box" perpendicular to the central axis of 0 °, and the length * width is 60cm * 50cm.**117 +**2. The object to be tested is a "corrugated cardboard box" perpendicular to the central axis of 0 °, and the length * width is 60cm * 50cm.** 117 117 118 118 [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDDS75%20-%20LoRaWAN%20Distance%20Detection%20Sensor%20User%20Manual/WebHome/1654852175653-550.png?rev=1.1||alt="1654852175653-550.png"]] 119 119 ... ... @@ -178,8 +178,8 @@ 178 178 [[image:image-20230523174230-1.png]] 179 179 180 180 182 +== == 181 181 182 - 183 183 == 2.10 Mechanical == 184 184 185 185 ... ... @@ -192,18 +192,6 @@ 192 192 [[image:Main.User Manual for LoRaWAN End Nodes.D20-LBD22-LBD23-LB_LoRaWAN_Temperature_Sensor_User_Manual.WebHome@1675143909447-639.png]] 193 193 194 194 195 -(% style="color:blue" %)**Probe Mechanical:** 196 - 197 - 198 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDDS75%20-%20LoRaWAN%20Distance%20Detection%20Sensor%20User%20Manual/WebHome/image-20220610172003-1.png?rev=1.1||alt="image-20220610172003-1.png"]] 199 - 200 - 201 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDDS75%20-%20LoRaWAN%20Distance%20Detection%20Sensor%20User%20Manual/WebHome/image-20220610172003-2.png?rev=1.1||alt="image-20220610172003-2.png"]] 202 - 203 - 204 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDDS75%20-%20LoRaWAN%20Distance%20Detection%20Sensor%20User%20Manual/WebHome/image-20220610172003-2.png?rev=1.1||alt="image-20220610172003-2.png"]] 205 - 206 - 207 207 = 2. Configure DDS75-LB to connect to LoRaWAN network = 208 208 209 209 == 2.1 How it works == ... ... @@ -254,10 +254,10 @@ 254 254 [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LSN50v2-S31-S31B%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20User%20Manual/WebHome/image-20220611161308-6.png?width=744&height=485&rev=1.1||alt="图片-20220611161308-6.png"]] 255 255 256 256 257 -(% style="color:blue" %)**Step 2:**(%%) Activate on DDS75-LB246 +(% style="color:blue" %)**Step 2:**(%%) Activate on SW3L-LB 258 258 259 259 260 -Press the button for 5 seconds to activate the DDS75-LB.249 +Press the button for 5 seconds to activate the SW3L-LB. 261 261 262 262 (% style="color:green" %)**Green led**(%%) will fast blink 5 times, device will enter (% style="color:blue" %)**OTA mode**(%%) for 3 seconds. And then start to JOIN LoRaWAN network. (% style="color:green" %)**Green led**(%%) will solidly turn on for 5 seconds after joined in network. 263 263 ... ... @@ -264,167 +264,355 @@ 264 264 After join success, it will start to upload messages to TTN and you can see the messages in the panel. 265 265 266 266 267 -== 2.3 256 +== 2.3 Uplink Payload == 268 268 258 +=== 2.3.1 Device Status, FPORT~=5 === 269 269 270 -((( 271 -DDS75-LB will uplink payload via LoRaWAN with below payload format: 272 -))) 273 273 274 -((( 275 -Uplink payload includes in total 8 bytes. 276 -))) 261 +Include device configure status. Once SW3L-LB Joined the network, it will uplink this message to the server. After that, SW3L-LB will uplink Device Status every 12 hours. 277 277 278 -(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:510px" %) 279 -|=(% style="width: 62.5px;background-color:#D9E2F3;color:#0070C0" %)((( 280 -**Size(bytes)** 281 -)))|=(% style="width: 62.5px;background-color:#D9E2F3;color:#0070C0" %)**2**|=(% style="background-color:#D9E2F3;color:#0070C0" %)**2**|=(% style="background-color:#D9E2F3;color:#0070C0" %)1|=(% style="background-color:#D9E2F3;color:#0070C0" %)2|=(% style="background-color:#D9E2F3;color:#0070C0" %)**1** 282 -|(% style="width:62.5px" %)**Value**|(% style="width:62.5px" %)[[BAT>>||anchor="H2.3.1A0BatteryInfo"]]|((( 283 -[[Distance>>||anchor="H2.3.2A0Distance"]] 284 -(unit: mm) 285 -)))|[[Digital Interrupt (Optional)>>||anchor="H2.3.3A0InterruptPin"]]|((( 286 -[[Temperature (Optional )>>||anchor="H2.3.4A0DS18B20Temperaturesensor"]] 287 -)))|[[Sensor Flag>>||anchor="H2.3.5A0SensorFlag"]] 263 +Users can use the downlink command(**0x26 01**) to ask SW3L-LB to send device configure detail, include device configure status. SW3L-LB will uplink a payload via FPort=5 to server. 288 288 289 - [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDDS75%20-%20LoRaWAN%20Distance%20Detection%20Sensor%20User%20Manual/WebHome/1654850511545-399.png?rev=1.1||alt="1654850511545-399.png"]]265 +The Payload format is as below. 290 290 291 291 292 -=== 2.3.1 Battery Info === 268 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %) 269 +|(% colspan="6" style="background-color:#d9e2f3; color:#0070c0" %)**Device Status (FPORT=5)** 270 +|(% style="width:103px" %)**Size (bytes)**|(% style="width:72px" %)**1**|**2**|(% style="width:91px" %)**1**|(% style="width:86px" %)**1**|(% style="width:44px" %)**2** 271 +|(% style="width:103px" %)**Value**|(% style="width:72px" %)Sensor Model|Firmware Version|(% style="width:91px" %)Frequency Band|(% style="width:86px" %)Sub-band|(% style="width:44px" %)BAT 293 293 273 +Example parse in TTNv3 294 294 295 - Check the battery voltageDDS75-LB.275 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/SW3L%20LoRaWAN%20Outdoor%20Flow%20Sensor/WebHome/1652925144491-755.png?width=732&height=139&rev=1.1||alt="1652925144491-755.png"]] 296 296 277 + 278 +(% style="color:#037691" %)**Sensor Model**(%%): For SW3L-LB, this value is 0x11 279 + 280 +(% style="color:#037691" %)**Firmware Version**(%%): 0x0100, Means: v1.0.0 version 281 + 282 +(% style="color:#037691" %)**Frequency Band**: 283 + 284 +*0x01: EU868 285 + 286 +*0x02: US915 287 + 288 +*0x03: IN865 289 + 290 +*0x04: AU915 291 + 292 +*0x05: KZ865 293 + 294 +*0x06: RU864 295 + 296 +*0x07: AS923 297 + 298 +*0x08: AS923-1 299 + 300 +*0x09: AS923-2 301 + 302 +*0x0a: AS923-3 303 + 304 +*0x0b: CN470 305 + 306 +*0x0c: EU433 307 + 308 +*0x0d: KR920 309 + 310 +*0x0e: MA869 311 + 312 + 313 +(% style="color:#037691" %)**Sub-Band**: 314 + 315 +AU915 and US915:value 0x00 ~~ 0x08 316 + 317 +CN470: value 0x0B ~~ 0x0C 318 + 319 +Other Bands: Always 0x00 320 + 321 + 322 +(% style="color:#037691" %)**Battery Info**: 323 + 324 +Check the battery voltage. 325 + 297 297 Ex1: 0x0B45 = 2885mV 298 298 299 299 Ex2: 0x0B49 = 2889mV 300 300 301 301 302 -=== 2.3.2 Distance===331 +=== 2.3.2 Sensor Configuration, FPORT~=4 === 303 303 304 304 334 +SW3L-LB will only send this command after getting the downlink command (0x26 02) from the server. 335 + 336 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:510px" %) 337 +|(% style="background-color:#d9e2f3; color:#0070c0; width:70px" %) **Size(bytes)**|(% style="background-color:#d9e2f3; color:#0070c0; width:105px" %)**3**|(% style="background-color:#d9e2f3; color:#0070c0; width:60px" %)**1**|(% style="background-color:#d9e2f3; color:#0070c0; width:96px" %)**1**|(% style="background-color:#d9e2f3; color:#0070c0; width:105px" %)**2**|(% style="background-color:#d9e2f3; color:#0070c0; width:74px" %)**1** 338 +|**Value**|(% style="width:104px" %)TDC(unit:sec)|(% style="width:43px" %)N/A|(% style="width:91px" %)Stop Timer|(% style="width:100px" %)Alarm Timer|(% style="width:69px" %)Reserve 339 + 340 +* (% style="color:#037691" %)**TDC: (default: 0x0004B0)** 341 + 342 +Uplink interval for the total pulse count, default value is 0x0004B0 which is 1200 seconds = 20 minutes. 343 + 344 + 345 +* (% style="color:#037691" %)**STOP Duration & Alarm Timer** 346 + 347 +Shows the configure value of [[Alarm for continuously water flow>>||anchor="H3.3.4Alarmforcontinuouslywaterflow"]] 348 + 349 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/SW3L%20LoRaWAN%20Outdoor%20Flow%20Sensor/WebHome/image-20220519095747-2.png?width=723&height=113&rev=1.1||alt="image-20220519095747-2.png"]] 350 + 351 + 352 +=== 2.3.3 Water Flow Value, Uplink FPORT~=2 === 353 + 354 + 305 305 ((( 306 - Getthe distance.Flat objectrange280mm-7500mm.356 +SW3L-LB will send this uplink **after** Device Status once join the LoRaWAN network successfully. And SW3L-LB will: 307 307 ))) 308 308 309 309 ((( 310 -For example, if the data you get from the register is 0x0B 0x05, the distance between the sensor and the measured object is(% style="color:#4472c4" %)** ** 360 +periodically send this uplink every 20 minutes, this interval [[can be changed>>||anchor="H3.3.1SetTransmitIntervalTime"]]. 361 +))) 311 311 312 -(% style="color:#4472c4" %)**0B05(H) = 2821 (D) = 2821 mm.** 363 +((( 364 +Uplink Payload totals 11 bytes. 313 313 ))) 314 314 367 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:510px" %) 368 +|=(% colspan="6" style="width: 510px;background-color:#D9E2F3;color:#0070C0" %)**Water Flow Value, FPORT=2** 369 +|(% style="width:60px" %)**Size(bytes)**|(% style="width:130px" %)**1**|(% style="width:130px" %)**4**|(% style="width:30px" %)**1**|(% style="width:50px" %)**1**|(% style="width:80px" %)**4** 370 +|(% style="width:110px" %)**Value**|(% style="width:81px" %)Calculate Flag & [[Alarm>>||anchor="H3.3.4Alarmforcontinuouslywaterflow"]]|(% style="width:95px" %)((( 371 +Total pulse Or Last Pulse 372 +)))|(% style="width:55px" %)MOD|(% style="width:115px" %)Reserve(0x01)|(% style="width:129px" %)[[Unix TimeStamp>>||anchor="H2.5.2UnixTimeStamp"]] 315 315 316 -* If the sensor value is 0x0000, it means system doesn't detect ultrasonic sensor. 317 -* If the sensor value lower than 0x0118 (280mm), the sensor value will be invalid. All value lower than 280mm will be set to 0x0014(20mm) which means the value is invalid. 374 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:470px" %) 375 +|=(% colspan="4" style="width: 470px;background-color:#D9E2F3;color:#0070C0" %)**Status & Alarm field** 376 +|(% style="width:60px" %)**Size(bit)**|(% style="width:80px" %)**6**|(% style="width:310px" %)**1**|(% style="width:20px" %)**1** 377 +|(% style="width:88px" %)**Value**|(% style="width:117px" %)Calculate Flag|(% style="width:221px" %)Alarm: 0: No Alarm; 1: Alarm|(% style="width:64px" %)N/A 318 318 379 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/SW3L%20LoRaWAN%20Outdoor%20Flow%20Sensor/WebHome/image-20220519095946-3.png?width=736&height=284&rev=1.1||alt="image-20220519095946-3.png"]] 319 319 320 -=== 2.3.3 Interrupt Pin === 321 321 382 +* ((( 383 +(% style="color:#037691" %)**Calculate Flag** 384 +))) 322 322 323 -This data field shows if this packet is generated by interrupt or not. [[Click here>>||anchor="H3.3.2SetInterruptMode"]] for the hardware and software set up. 386 +((( 387 +The calculate flag is a user defined field, IoT server can use this flag to handle different meters with different pulse factors. For example, if there are 100 Flow Sensors, meters 1 ~~50 are 1 liter/pulse and meters 51 ~~ 100 has 1.5 liter/pulse. 388 +))) 324 324 325 -**Example:** 390 +((( 391 +**Example: in the default payload:** 392 +))) 326 326 327 -0x00: Normal uplink packet. 394 +* ((( 395 +calculate flag=0: for SW3L-004 Flow Sensor: 450 pulse = 1 L 396 +))) 397 +* ((( 398 +calculate flag=1: for SW3L-006 Flow Sensor: 390 pulse = 1 L 399 +))) 400 +* ((( 401 +calculate flag=2: for SW3L-010 Flow Sensor: 64 pulse = 1 L 402 +))) 328 328 329 -0x01: Interrupt Uplink Packet. 404 +((( 405 +Default value: 0. 406 +))) 330 330 408 +((( 409 +Range (6 bits): (b)000000 ~~ (b) 111111 331 331 332 - ===2.3.4DS18B20Temperaturesensor===411 +If user use with a meter for example is 0.02L/pulse. To proper decode the correct value in server, 333 333 413 +1) User can set the Calculate Flag of this sensor to 3. 334 334 335 -This is optional, user can connect external DS18B20 sensor to the +3.3v, 1-wire and GND pin . and this field will report temperature. 415 +2) In server side, when a sensor data arrive, the decoder will check the value of Calculate Flag, It the value is 3, the total volume = 0.02 x Pulse Count. 416 +))) 336 336 337 -**Example**: 418 +((( 419 +(% style="color:red" %)**NOTE: User need to set Calculate Flag to proper value before use Flow Sensor. Downlink or AT Command see: **(%%)Refer: [[Set Calculate Flag>>||anchor="H3.3.6Setthecalculateflag"]] 420 +))) 338 338 339 -If payload is: 0105H: (0105 & FC00 == 0), temp = 0105H /10 = 26.1 degree 422 +* ((( 423 +(% style="color:#037691" %)**Alarm** 424 +))) 340 340 341 -If payload is: FF3FH : (FF3F & FC00 == 1) , temp = (FF3FH - 65536)/10 = -19.3 degrees. 426 +((( 427 +See [[Alarm for continuously water flow>>||anchor="H3.3.4Alarmforcontinuouslywaterflow"]] 428 +))) 342 342 430 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/SW3L%20LoRaWAN%20Outdoor%20Flow%20Sensor/WebHome/image-20220519095946-4.png?width=724&height=65&rev=1.1||alt="image-20220519095946-4.png"]] 343 343 344 -=== 2.3.5 Sensor Flag === 345 345 433 +* ((( 434 +(% style="color:#037691" %)**Total pulse** 435 +))) 346 346 347 347 ((( 348 - 0x01: DetectUltrasonic Sensor438 +Total pulse/counting since factory 349 349 ))) 350 350 351 351 ((( 352 -0x00 :NoUltrasonic Sensor442 +Range (4 Bytes) : 0x00000000~~ 0xFFFFFFFF . 353 353 ))) 354 354 445 +* ((( 446 +(% style="color:#037691" %)**Last Pulse** 447 +))) 355 355 356 -=== 2.3.6 Decode payload in The Things Network === 449 +((( 450 +Total pulse since last FPORT=2 uplink. (Default 20 minutes) 451 +))) 357 357 453 +((( 454 +Range (4 Bytes) : 0x00000000~~ 0xFFFFFFFF . 455 +))) 358 358 359 -While using TTN network, you can add the payload format to decode the payload. 457 +* ((( 458 +(% style="color:#037691" %)**MOD: Default =0** 459 +))) 360 360 361 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDDS75%20-%20LoRaWAN%20Distance%20Detection%20Sensor%20User%20Manual/WebHome/1654850829385-439.png?rev=1.1||alt="1654850829385-439.png"]] 461 +((( 462 +MOD=0 ~-~-> Uplink Total Pulse since factory 463 +))) 362 362 363 -The payload decoder function for TTN V3 is here: 465 +((( 466 +MOD=1 ~-~-> Uplink total pulse since last FPORT=2 uplink. 467 +))) 364 364 469 +* ((( 470 +(% style="color:#037691" %)**Water Flow Value** 471 +))) 472 + 365 365 ((( 366 - DDS75-LBTTNV3 PayloadDecoder: [[ttps:~~/~~/github.com/dragino/dragino-end-node-decoder>>https://github.com/dragino/dragino-end-node-decoder]]474 +**Total Water Flow Volume = (Calculate Flag) x (Total Pulse)=9597/450=21.3L** 367 367 ))) 368 368 477 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/SW3L%20LoRaWAN%20Outdoor%20Flow%20Sensor/WebHome/image-20220519095946-5.png?width=727&height=50&rev=1.1||alt="image-20220519095946-5.png"]] 369 369 370 -== 2.4 Uplink Interval == 371 371 480 +((( 481 +**Total Water Flow for TDC timer = (Calculate Flag) x (Last Pulse)=79/450=0.2L** 482 +))) 372 372 373 - The DDS75-LB by defaultuplinkthe sensordata every 20 minutes.Usercanchange this intervalby AT CommandrLoRaWANDownlink Command.Seethis link: [[ChangeUplink Interval>>||anchor="H3.3.1SetTransmitIntervalTime"]]484 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/SW3L%20LoRaWAN%20Outdoor%20Flow%20Sensor/WebHome/image-20220519095946-6.png?width=733&height=43&rev=1.1||alt="image-20220519095946-6.png"]] ** ** 374 374 375 375 376 -== 2. 5Show Datain DataCakeIoTServer==487 +=== 2.3.4 Historical Water Flow Status, FPORT~=3 === 377 377 378 378 379 379 ((( 380 - [[DATACAKE>>url:https://datacake.co/]] provides ahumanfriendly interface to show thensordata, oncewe have datain TTN, we canuse [[DATACAKE>>url:https://datacake.co/]] to connecttoTTNandsee the datain DATACAKE. Belowarethe steps:491 +SW3L-LB stores sensor values and users can retrieve these history values via the [[downlink command>>||anchor="H2.5DatalogFeature"]]. 381 381 ))) 382 382 494 +((( 495 +The historical payload includes one or multiplies entries and every entry has the same payload as Real-Time water flow status. 496 +))) 383 383 498 +* ((( 499 +Each data entry is 11 bytes and has the same structure as [[real time water flow status>>||anchor="H2.3.3A0WaterFlowValue2CUplinkFPORT3D2"]], to save airtime and battery, SW3L will send max bytes according to the current DR and Frequency bands. 500 +))) 501 + 384 384 ((( 385 - (% style="color:blue"%)**Step1**(%%)**: Besurethat your deviceisprogrammed andproperlyconnectedtothenetworkatthistime.**503 +For example, in the US915 band, the max payload for different DR is: 386 386 ))) 387 387 388 388 ((( 389 -(% style="color:blue" %)** Step2**(%%)**:ToconfiguretheApplicationtoforward data to DATACAKE you willneedto add integration.Toadd the DATACAKE integration, perform the following steps:**507 +(% style="color:blue" %)**a) DR0:**(%%) max is 11 bytes so one entry of data 390 390 ))) 391 391 510 +((( 511 +(% style="color:blue" %)**b) DR1:**(%%) max is 53 bytes so devices will upload 4 entries of data (total 44 bytes) 512 +))) 392 392 393 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDDS75%20-%20LoRaWAN%20Distance%20Detection%20Sensor%20User%20Manual/WebHome/1654592790040-760.png?rev=1.1||alt="1654592790040-760.png"]] 514 +((( 515 +(% style="color:blue" %)**c) DR2:**(%%) total payload includes 11 entries of data 516 +))) 394 394 518 +((( 519 +(% style="color:blue" %)**d) DR3:**(%%) total payload includes 22 entries of data. 520 +))) 395 395 396 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDDS75%20-%20LoRaWAN%20Distance%20Detection%20Sensor%20User%20Manual/WebHome/1654592800389-571.png?rev=1.1||alt="1654592800389-571.png"]] 522 +((( 523 +If SW3L-LB doesn't have any data in the polling time. It will uplink 11 bytes of 0 524 +))) 397 397 526 +((( 527 +(% style="color:#037691" %)**Downlink:** 528 +))) 398 398 399 -(% style="color:blue" %)**Step 3**(%%)**: Create an account or log in Datacake.** 530 +((( 531 +0x31 62 46 B1 F0 62 46 B3 94 07 532 +))) 400 400 401 - (% style="color:blue"%)**Step 4**(%%)**:Search theDDS75-LB andadd DevEUI.**534 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/SW3L%20LoRaWAN%20Outdoor%20Flow%20Sensor/WebHome/1652926690850-712.png?width=726&height=115&rev=1.1||alt="1652926690850-712.png"]] 402 402 403 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDDS75%20-%20LoRaWAN%20Distance%20Detection%20Sensor%20User%20Manual/WebHome/1654851029373-510.png?rev=1.1||alt="1654851029373-510.png"]] 404 404 537 +((( 538 +(% style="color:#037691" %)**Uplink:** 539 +))) 405 405 406 -After added, the sensor data arrive TTN V3, it will also arrive and show in Datacake. 541 +((( 542 +00 00 01 00 00 00 00 62 46 B2 26 00 00 01 00 00 00 00 62 46 B2 5D 00 00 01 00 00 00 00 62 46 B2 99 00 00 01 00 00 00 00 62 46 B2 D5 00 00 01 00 00 01 15 62 46 B3 11 00 00 01 00 00 01 1F 62 46 B3 7E 543 +))) 407 407 408 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDDS75%20-%20LoRaWAN%20Distance%20Detection%20Sensor%20User%20Manual/WebHome/image-20220610165129-11.png?width=1088&height=595&rev=1.1||alt="image-20220610165129-11.png"]] 545 +((( 546 +(% style="color:#037691" %)**Parsed Value:** 547 +))) 409 409 549 +((( 550 +[Alarm, Calculate Flag, MOD, Total pulse or Last Pulse,** **Water Flow Value, TIME] 551 +))) 410 410 411 411 412 -== 2.6 Datalog Feature == 554 +((( 555 +[FALSE,0,0,0,0.0,2022-04-01 08:04:54], 556 +))) 413 413 558 +((( 559 +[FALSE,0,0,0,0.0,2022-04-01 08:05:49], 560 +))) 414 414 415 -Datalog Feature is to ensure IoT Server can get all sampling data from Sensor even if the LoRaWAN network is down. For each sampling, DDS75-LB will store the reading for future retrieving purposes. 562 +((( 563 +[FALSE,0,0,0,0.0,2022-04-01 08:06:49], 564 +))) 416 416 566 +((( 567 +[FALSE,0,0,0,0.0,2022-04-01 08:07:49], 568 +))) 417 417 418 -=== 2.6.1 Ways to get datalog via LoRaWAN === 570 +((( 571 +[FALSE,0,0,277,0.6,2022-04-01 08:08:49], 572 +))) 419 419 574 +((( 575 +[FALSE,0,0,287,0.6,2022-04-01 08:10:38], 576 +))) 420 420 421 - SetPNACKMD=1, DDS75-LBwill wait for ACK for every uplink,whenthereisetwork,DDS75-LB will markthese records with non-ack messages andstorethesensor data, and itwill sendall messages (10sinterval) after the network recovery.578 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/SW3L%20LoRaWAN%20Outdoor%20Flow%20Sensor/WebHome/1652926777796-267.png?width=724&height=279&rev=1.1||alt="1652926777796-267.png"]] 422 422 580 + 581 +== 2.4 Payload Decoder file == 582 + 583 + 584 +In TTN, use can add a custom payload so it shows friendly reading 585 + 586 +In the page (% style="color:#037691" %)**Applications ~-~-> Payload Formats ~-~-> Custom ~-~-> decoder**(%%) to add the decoder from: [[https:~~/~~/github.com/dragino/dragino-end-node-decoder>>https://github.com/dragino/dragino-end-node-decoder]] 587 + 588 + 589 +== 2.5 Datalog Feature == 590 + 591 + 592 +Datalog Feature is to ensure IoT Server can get all sampling data from Sensor even if the LoRaWAN network is down. For each sampling, SW3L-LB will store the reading for future retrieving purposes. 593 + 594 + 595 +=== 2.5.1 Ways to get datalog via LoRaWAN === 596 + 597 + 598 +Set PNACKMD=1, SW3L-LB will wait for ACK for every uplink, when there is no LoRaWAN network,SW3L-LB will mark these records with non-ack messages and store the sensor data, and it will send all messages (10s interval) after the network recovery. 599 + 423 423 * ((( 424 -a) DDS75-LB will do an ACK check for data records sending to make sure every data arrive server.601 +a) SW3L-LB will do an ACK check for data records sending to make sure every data arrive server. 425 425 ))) 426 426 * ((( 427 -b) DDS75-LB will send data in **CONFIRMED Mode** when PNACKMD=1, butDDS75-LB won't re-transmit the packet if it doesn't get ACK, it will just mark it as a NONE-ACK message. In a future uplink ifDDS75-LB gets a ACK,DDS75-LB will consider there is a network connection and resend all NONE-ACK messages.604 +b) SW3L-LB will send data in **CONFIRMED Mode** when PNACKMD=1, but SW3L-LB won't re-transmit the packet if it doesn't get ACK, it will just mark it as a NONE-ACK message. In a future uplink if SW3L-LB gets a ACK, SW3L-LB will consider there is a network connection and resend all NONE-ACK messages. 428 428 ))) 429 429 430 430 Below is the typical case for the auto-update datalog feature (Set PNACKMD=1) ... ... @@ -432,10 +432,10 @@ 432 432 [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/WebHome/image-20220703111700-2.png?width=1119&height=381&rev=1.1||alt="图片-20220703111700-2.png" height="381" width="1119"]] 433 433 434 434 435 -=== 2. 6.2 Unix TimeStamp ===612 +=== 2.5.2 Unix TimeStamp === 436 436 437 437 438 - DDS75-LB uses Unix TimeStamp format based on615 +SW3L-LB uses Unix TimeStamp format based on 439 439 440 440 [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/WebHome/image-20220523001219-11.png?width=627&height=97&rev=1.1||alt="图片-20220523001219-11.png" height="97" width="627"]] 441 441 ... ... @@ -449,17 +449,17 @@ 449 449 So, we can use AT+TIMESTAMP=1611889405 or downlink 3060137afd00 to set the current time 2021 – Jan ~-~- 29 Friday 03:03:25 450 450 451 451 452 -=== 2. 6.3 Set Device Time ===629 +=== 2.5.3 Set Device Time === 453 453 454 454 455 455 User need to set (% style="color:blue" %)**SYNCMOD=1**(%%) to enable sync time via MAC command. 456 456 457 -Once DDS75-LB Joined LoRaWAN network, it will send the MAC command (DeviceTimeReq) and the server will reply with (DeviceTimeAns) to send the current time toDDS75-LB. IfDDS75-LB fails to get the time from the server,DDS75-LB will use the internal time and wait for next time request (AT+SYNCTDC to set the time request period, default is 10 days).634 +Once SW3L-LB Joined LoRaWAN network, it will send the MAC command (DeviceTimeReq) and the server will reply with (DeviceTimeAns) to send the current time to SW3L-LB. If SW3L-LB fails to get the time from the server, SW3L-LB will use the internal time and wait for next time request (AT+SYNCTDC to set the time request period, default is 10 days). 458 458 459 459 (% style="color:red" %)**Note: LoRaWAN Server need to support LoRaWAN v1.0.3(MAC v1.0.3) or higher to support this MAC command feature, Chirpstack,TTN V3 v3 and loriot support but TTN V3 v2 doesn't support. If server doesn't support this command, it will through away uplink packet with this command, so user will lose the packet with time request for TTN V3 v2 if SYNCMOD=1.** 460 460 461 461 462 -=== 2. 6.4 Poll sensor value ===639 +=== 2.5.4 Poll sensor value === 463 463 464 464 465 465 Users can poll sensor values based on timestamps. Below is the downlink command. ... ... @@ -482,24 +482,24 @@ 482 482 ))) 483 483 484 484 ((( 485 -Uplink Internal =5s,means DDS75-LB will send one packet every 5s. range 5~~255s.662 +Uplink Internal =5s,means SW3L-LB will send one packet every 5s. range 5~~255s. 486 486 ))) 487 487 488 488 489 -== 2. 7Frequency Plans ==666 +== 2.6 Frequency Plans == 490 490 491 491 492 -The DDS75-LB uses OTAA mode and below frequency plans by default. If user want to use it with different frequency plan, please refer the AT command sets.669 +The SW3L-LB uses OTAA mode and below frequency plans by default. If user want to use it with different frequency plan, please refer the AT command sets. 493 493 494 494 [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20Frequency%20Band/>>http://wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20Frequency%20Band/]] 495 495 496 496 497 -= 3. Configure DDS75-LB =674 += 3. Configure SW3L-LB = 498 498 499 499 == 3.1 Configure Methods == 500 500 501 501 502 - DDS75-LB supports below configure method:679 +SW3L-LB supports below configure method: 503 503 504 504 * AT Command via Bluetooth Connection (**Recommended**): [[BLE Configure Instruction>>http://wiki.dragino.com/xwiki/bin/view/Main/BLE%20Bluetooth%20Remote%20Configure/]]. 505 505 ... ... @@ -521,10 +521,10 @@ 521 521 [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/>>http://wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/]] 522 522 523 523 524 -== 3.3 Commands special design for DDS75-LB ==701 +== 3.3 Commands special design for SW3L-LB == 525 525 526 526 527 -These commands only valid for DDS75-LB, as below:704 +These commands only valid for SW3L-LB, as below: 528 528 529 529 530 530 === 3.3.1 Set Transmit Interval Time === ... ... @@ -569,134 +569,259 @@ 569 569 Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds 570 570 ))) 571 571 572 -=== 3.3.2 Set InterruptMode===749 +=== 3.3.2 Quit AT Command === 573 573 574 574 575 -Feature ,SetInterruptmodeforPA8of pin.752 +Feature: Quit AT Command mode, so user needs to input the password again before using AT Commands. 576 576 577 - WhenAT+INTMOD=0 isset, PA8 isusedasaigitalinput port.754 +(% style="color:blue" %)**AT Command: AT+DISAT** 578 578 579 -(% style="color:blue" %)**AT Command: AT+INTMOD** 756 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:452px" %) 757 +|=(% style="width: 155px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 198px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 99px;background-color:#D9E2F3;color:#0070C0" %)**Response** 758 +|(% style="width:155px" %)AT+DISAT|(% style="width:198px" %)Quit AT Commands mode|(% style="width:96px" %)OK 580 580 581 -(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %) 582 -|=(% style="width: 155px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 197px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 158px;background-color:#D9E2F3;color:#0070C0" %)**Response** 583 -|(% style="width:154px" %)AT+INTMOD=?|(% style="width:196px" %)Show current interrupt mode|(% style="width:157px" %)((( 584 -0 585 -OK 586 -the mode is 0 =Disable Interrupt 760 +(% style="color:blue" %)**Downlink Command:** 761 + 762 +No downlink command for this feature. 763 + 764 + 765 +=== 3.3.3 Get Device Status === 766 + 767 + 768 +Send a LoRaWAN downlink to ask device send Alarm settings. 769 + 770 +(% style="color:blue" %)**Downlink Payload: **(%%)0x26 01 771 + 772 +Sensor will upload Device Status via FPORT=5. See payload section for detail. 773 + 774 + 775 +=== 3.3.4 Alarm for continuously water flow === 776 + 777 + 778 +((( 779 +This feature is to monitor and send Alarm for continuously water flow. 587 587 ))) 588 -|(% style="width:154px" %)AT+INTMOD=2|(% style="width:196px" %)((( 589 -Set Transmit Interval 590 -0. (Disable Interrupt), 591 -~1. (Trigger by rising and falling edge) 592 -2. (Trigger by falling edge) 593 -3. (Trigger by rising edge) 594 -)))|(% style="width:157px" %)OK 595 595 596 -(% style="color:blue" %)**Downlink Command: 0x06** 782 +((( 783 +Example case is for Toilet water monitoring, if some one push toilet button, the toilet will have water flow. If the toilet button has broken and can't returned to original state, the water flow will keep for hours or days which cause huge waste for water. 784 +))) 597 597 598 -Format: Command Code (0x06) followed by 3 bytes. 786 +((( 787 +To monitor this faulty and send alarm, there are two settings: 788 +))) 599 599 600 -This means that the interrupt mode of the end node is set to 0x000003=3 (rising edge trigger), and the type code is 06. 790 +* ((( 791 +(% style="color:#4f81bd" %)**Stop Duration: Unit: Second** 792 +))) 601 601 602 -* Example 1: Downlink Payload: 06000000 ~/~/ Turn off interrupt mode 794 +((( 795 +Default: 15s, If SW3L-LB didn't see any water flow in 15s, SW3L-LB will consider stop of water flow event. 796 +))) 603 603 604 -* Example 2: Downlink Payload: 06000003 ~/~/ Set the interrupt mode to rising edge trigger 798 +* ((( 799 +(% style="color:#4f81bd" %)**Alarm Timer: Units: Minute; Default 0 minutes (means Alarm disable)** 800 +))) 605 605 606 -= 4. Battery & Power Consumption = 802 +((( 803 +**Example:** 3 minutes, if SW3L-LB detect a start of water flow event and didn't detect a stop event within Alarm timer, SW3L-LB will send an Alarm to indicate a water flow abnormal alarm. 804 +))) 607 607 806 +((( 807 +So for example, If we set stop duration=15s and Alarm Timer=3minutes. If the toilet water flow continuously for more than 3 minutes, Sensor will send an alarm (in Confirmed MODE) to platform. 808 +))) 608 608 609 -DDS75-LB use ER26500 + SPC1520 battery pack. See below link for detail information about the battery info and how to replace. 810 +((( 811 +(% style="color:red" %)**Note:** **After this alarm is send, sensor will consider a stop of water flow and count for another new event. So if water flow waste last for 1 hour, Sensor will keep sending alarm every 3 minutes.** 812 +))) 610 610 611 -[[**Battery Info & Power Consumption Analyze**>>http://wiki.dragino.com/xwiki/bin/view/Main/How%20to%20calculate%20the%20battery%20life%20of%20Dragino%20sensors%3F/]] . 814 +((( 815 +(% style="color:#4f81bd" %)**AT Command**(%%) to configure: 816 +))) 612 612 818 +* ((( 819 +AT+PTRIG=15,3 ~-~-> Set Stop duration: 15s, Alarm Timer: 3 minutes. 820 +))) 613 613 614 -= 5. OTA Firmware update = 822 +* ((( 823 +AT+ PTRIG=15,0 ~-~-> Default Value, disable water waste Alarm. 824 +))) 615 615 826 +((( 827 +(% style="color:#4f81bd" %)**Downlink Command**(%%) to configure: 828 +))) 616 616 617 -(% class="wikigeneratedid" %) 618 -User can change firmware DDS75-LB to: 830 +((( 831 +Command: **0xAA aa bb cc** 832 +))) 619 619 620 -* Change Frequency band/ region. 834 +((( 835 +AA: Command Type Code 836 +))) 621 621 622 -* Update with new features. 838 +((( 839 +aa: Stop duration 840 +))) 623 623 624 -* Fix bugs. 842 +((( 843 +bb cc: Alarm Timer 844 +))) 625 625 626 -Firmware and changelog can be downloaded from : **[[Firmware download link>>url:https://www.dropbox.com/sh/7la95mae0fn03xe/AACtzs-32m22TLb75B-iIr-Qa?dl=0]]** 846 +((( 847 +If user send 0xAA 0F 00 03: equal to AT+PTRIG=15,3 848 +))) 627 627 628 -Methods to Update Firmware: 629 629 630 - *(Recommandedway) OTA firmwareupdate via wireless: [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/Firmware%20OTA%20Update%20for%20Sensors/>>url:http://wiki.dragino.com/xwiki/bin/view/Main/Firmware%20OTA%20Update%20for%20Sensors/]]851 +=== 3.3.5 Clear Flash Record === 631 631 632 -* Update through UART TTL interface: **[[Instruction>>url:http://wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H1.LoRaSTv4baseHardware]]**. 633 633 634 - =6.FAQ=854 +Feature: Clear flash storage for data log feature. 635 635 636 - ==6.1 What ishefrequencyplanfor DDS75-LB? ==856 +(% style="color:blue" %)**AT Command: AT+CLRDTA** 637 637 858 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:500px" %) 859 +|=(% style="width: 157px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 169px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 174px;background-color:#D9E2F3;color:#0070C0" %)**Response** 860 +|(% style="width:157px" %)AT+CLRDTA|(% style="width:169px" %)Clear flash storage for data log feature.|Clear all stored sensor data… OK 638 638 639 -DDS75-LB use the same frequency as other Dragino products. User can see the detail from this link: [[Introduction>>doc:Main.End Device Frequency Band.WebHome||anchor="H1.Introduction"]] 862 +((( 863 +(% style="color:blue" %)**Downlink Command:** 864 +))) 640 640 866 +((( 867 +* **Example**: 0xA301 ~/~/ Same as AT+CLRDTA 868 +))) 641 641 642 -== 6.2 Can I use DDS75-LB in condensation environment? == 643 643 644 644 645 - DDS75-LBis not suitable to be used in condensation environment.CondensationontheDDS75-LB probe willffectthereading and alwaysgot0.872 +=== 3.3.6 Set the calculate flag === 646 646 647 647 648 - = 7. Trouble Shooting=875 +Feature: Set the calculate flag 649 649 650 - ==7.1 WhyIcan't joinTTNV3 in US915 / AU915 bands?==877 +(% style="color:blue" %)**AT Command: AT+CALCFLAG** 651 651 879 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:461px" %) 880 +|=(% style="width: 158px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 193px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 110px;background-color:#D9E2F3;color:#0070C0" %)**Response** 881 +|(% style="width:158px" %)AT+CALCFLAG =1|(% style="width:192px" %)Set the calculate flag to 1.|(% style="width:109px" %)OK 882 +|(% style="width:158px" %)AT+CALCFLAG =2|(% style="width:192px" %)Set the calculate flag to 2.|(% style="width:109px" %)OK 652 652 653 - Itisdueto channelmapping. Pleasesee below: [[Frequencyband>>doc:Main.LoRaWANCommunicationDebug.WebHome||anchor="H2.NoticeofUS9152FCN4702FAU915Frequencyband"]]884 +(% style="color:blue" %)**Downlink Command:** 654 654 886 +* **Example**: 0XA501 ~/~/ Same as AT+CALCFLAG =1 655 655 656 -== 7.2ATCommandinput doesn't work==888 +=== 3.3.7 Set count number === 657 657 658 658 659 - In thecase ifusercan seethe console output but can't type input to the device. Please check if you already include the (% style="color:blue"%)**ENTER**(%%) whilesending out the command. Some serialtooldoesn't send (% style="color:blue" %)**ENTER**(%%) while press the send key, user need to add ENTER in their string.891 +Feature: Manually set the count number 660 660 893 +(% style="color:blue" %)**AT Command: AT+SETCNT** 661 661 662 -== 7.3 Why does the sensor reading show 0 or "No sensor" == 895 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:479px" %) 896 +|=(% style="width: 160px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 223px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 96px;background-color:#D9E2F3;color:#0070C0" %)**Response** 897 +|(% style="width:160px" %)AT+ SETCNT =0|(% style="width:221px" %)Set the count number to 0.|(% style="width:95px" %)OK 898 +|(% style="width:160px" %)AT+ SETCNT =100|(% style="width:221px" %)Set the count number to 100.|(% style="width:95px" %)OK 663 663 900 +(% style="color:blue" %)**Downlink Command:** 664 664 665 - ~1.The measurementobjectisveryclosetothesensor,but in the blindspotofthesensor.902 +* **Example**: 0xA6000001 ~/~/ Same as AT+ SETCNT =1 666 666 667 - 2.Sensorwiringisdisconnected904 +* **Example**: 0xA6000064 ~/~/ Same as AT+ SETCNT =100 668 668 669 -3. Notusingthecorrectdecoder906 +=== 3.3.8 Set Interrupt Mode === 670 670 671 671 672 - == 7.4 Abnormal readings The gap between multiplereadingsis too largeorthegap betweenheeadingsandtheactualvalueis toolarge ==909 +Feature, Set Interrupt mode for PA8 of pin. 673 673 911 +When AT+INTMOD=0 is set, PA8 is used as a digital input port. 674 674 675 - 1)Please check ifthere is somethingon the probeaffectingitsmeasurement (condensedwater, volatile oil, etc.)913 +(% style="color:blue" %)**AT Command: AT+INTMOD** 676 676 677 -2) Does it change with temperature, temperature will affect its measurement 915 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %) 916 +|=(% style="width: 155px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 197px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 158px;background-color:#D9E2F3;color:#0070C0" %)**Response** 917 +|(% style="width:154px" %)AT+INTMOD=?|(% style="width:196px" %)Show current interrupt mode|(% style="width:157px" %)((( 918 +0 919 +OK 920 +the mode is 0 =Disable Interrupt 921 +))) 922 +|(% style="width:154px" %)AT+INTMOD=2|(% style="width:196px" %)((( 923 +Set Transmit Interval 924 +0. (Disable Interrupt), 925 +~1. (Trigger by rising and falling edge) 926 +2. (Trigger by falling edge) 927 +3. (Trigger by rising edge) 928 +)))|(% style="width:157px" %)OK 678 678 679 - 3)If abnormal data occurs,youcan turnon DEBUG mode, Pleaseusedownlinkor ATCOMMAN toenter DEBUGmode.930 +(% style="color:blue" %)**Downlink Command: 0x06** 680 680 681 - downlinkcommand:(% style="color:blue"%)**F1 01**(%%),AT command: (% style="color:blue"%)**AT+DDEBUG=1**932 +Format: Command Code (0x06) followed by 3 bytes. 682 682 683 - 4)After enteringthedebugmode,itwill send20piecesof dataatatime, andyou can sendits uplinktous for analysis934 +This means that the interrupt mode of the end node is set to 0x000003=3 (rising edge trigger), and the type code is 06. 684 684 685 - [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDDS75%20-%20LoRaWAN%20Distance%20Detection%20Sensor%20User%20Manual/WebHome/image-20230113135125-2.png?width=1057&height=136&rev=1.1||alt="image-20230113135125-2.png"]]936 +* Example 1: Downlink Payload: 06000000 ~/~/ Turn off interrupt mode 686 686 938 +* Example 2: Downlink Payload: 06000003 ~/~/ Set the interrupt mode to rising edge trigger 687 687 688 - Itsoriginalpayload will belongerthanotherdata. Even though it is being parsed, it can beseen that it is abnormal data.940 +=== 3.3.9 Set work mode === 689 689 690 -Please send the data to us for check. 691 691 943 +Feature: Manually set the work mode 692 692 693 -= 8. Order Info = 694 694 946 +(% style="color:blue" %)**AT Command: AT+MOD** 695 695 696 -Part Number: (% style="color:blue" %)**DDS75-LB-XXX** 948 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:463px" %) 949 +|=(% style="width: 162px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 193px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 108px;background-color:#D9E2F3;color:#0070C0" %)**Response** 950 +|(% style="width:162px" %)AT+MOD=0|(% style="width:191px" %)Set the work mode to 0.|(% style="width:106px" %)OK 951 +|(% style="width:162px" %)AT+MOD=1|(% style="width:191px" %)Set the work mode to 1|(% style="width:106px" %)OK 697 697 698 -(% style="color: red" %)**XXX**(%%): **The default frequencyband**953 +(% style="color:blue" %)**Downlink Command:** 699 699 955 +* **Example: **0x0A00 ~/~/ Same as AT+MOD=0 956 + 957 +* **Example:** 0x0A01 ~/~/ Same as AT+MOD=1 958 + 959 += 4. Battery & Power Consumption = 960 + 961 + 962 +SW3L-LB use ER26500 + SPC1520 battery pack. See below link for detail information about the battery info and how to replace. 963 + 964 +[[**Battery Info & Power Consumption Analyze**>>http://wiki.dragino.com/xwiki/bin/view/Main/How%20to%20calculate%20the%20battery%20life%20of%20Dragino%20sensors%3F/]] . 965 + 966 + 967 += 5. OTA Firmware update = 968 + 969 + 970 +(% class="wikigeneratedid" %) 971 +User can change firmware SW3L-LB to: 972 + 973 +* Change Frequency band/ region. 974 + 975 +* Update with new features. 976 + 977 +* Fix bugs. 978 + 979 +Firmware and changelog can be downloaded from : **[[Firmware download link>>url:https://www.dropbox.com/sh/kwqv57tp6pejias/AAAopYMATh1GM6fZ-VRCLrpDa?dl=0]]** 980 + 981 +Methods to Update Firmware: 982 + 983 +* (Recommanded way) OTA firmware update via wireless: [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/Firmware%20OTA%20Update%20for%20Sensors/>>url:http://wiki.dragino.com/xwiki/bin/view/Main/Firmware%20OTA%20Update%20for%20Sensors/]] 984 + 985 +* Update through UART TTL interface. **[[Instruction>>url:http://wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H1.LoRaSTv4baseHardware]]**. 986 + 987 += 6. FAQ = 988 + 989 +== 6.1 AT Commands input doesn't work == 990 + 991 + 992 +In the case if user can see the console output but can't type input to the device. Please check if you already include the (% style="color:green" %)**ENTER**(%%) while sending out the command. Some serial tool doesn't send (% style="color:green" %)**ENTER**(%%) while press the send key, user need to add ENTER in their string. 993 + 994 + 995 += 7. Order Info = 996 + 997 + 998 +Part Number: (% style="color:blue" %)**SW3L-LB-XXX-YYY** 999 + 1000 +(% style="color:red" %)**XXX**(%%): The default frequency band 1001 + 700 700 * (% style="color:red" %)**AS923**(%%): LoRaWAN AS923 band 701 701 702 702 * (% style="color:red" %)**AU915**(%%): LoRaWAN AU915 band ... ... @@ -713,13 +713,43 @@ 713 713 714 714 * (% style="color:red" %)**CN470**(%%): LoRaWAN CN470 band 715 715 1018 +((( 1019 +(% style="color:blue" %)**YYY**(%%): Flow Sensor Model: 1020 +))) 716 716 717 -= 9. Packing Info = 1022 +((( 1023 + **004:** DW-004 Flow Sensor: diameter: G1/2” / DN15. 450 pulse = 1 L 1024 +))) 718 718 1026 +((( 1027 + **006:** DW-006 Flow Sensor: diameter: G3/4” / DN20. 390 pulse = 1 L 1028 +))) 719 719 1030 +((( 1031 + **010:** DW-010 Flow Sensor: diameter: G 1” / DN25. 64 pulse = 1 L 1032 +))) 1033 + 1034 +* ((( 1035 +calculate flag=0: for SW3L-004 Flow Sensor: 450 pulse = 1 L 1036 +))) 1037 + 1038 +* ((( 1039 +calculate flag=1: for SW3L-006 Flow Sensor: 390 pulse = 1 L 1040 +))) 1041 + 1042 +* ((( 1043 +calculate flag=2: for SW3L-010 Flow Sensor: 64 pulse = 1 L 1044 + 1045 + 1046 + 1047 +))) 1048 + 1049 += 8. Packing Info = 1050 + 1051 + 720 720 (% style="color:#037691" %)**Package Includes**: 721 721 722 -* DDS75-LB LoRaWANDistance DetectionSensorx 11054 +* SW3L-LB LoRaWAN Flow Sensor 723 723 724 724 (% style="color:#037691" %)**Dimension and weight**: 725 725 ... ... @@ -731,10 +731,9 @@ 731 731 732 732 * Weight / pcs : g 733 733 1066 += 9. Support = 734 734 735 -= 10. Support = 736 736 737 - 738 738 * Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule. 739 739 740 740 * Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[Support@dragino.cc>>mailto:Support@dragino.cc]].