Last modified by Mengting Qiu on 2023/12/14 11:15

From version 70.27
edited by Xiaoling
on 2023/06/13 09:16
Change comment: There is no comment for this version
To version 70.4
edited by Xiaoling
on 2023/06/12 17:15
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -22,13 +22,13 @@
22 22  
23 23  It detects the distance(% style="color:blue" %)**  between the measured object and the sensor**(%%), and uploads the value via wireless to LoRaWAN IoT Server.
24 24  
25 -The LoRa wireless technology used in DDS75-LB allows device to send data and reach extremely long ranges at low data-rates. It provides ultra-long range spread spectrum communication and high interference immunity whilst minimizing current consumption.
25 +The LoRa wireless technology used in SW3L-LB allows device to send data and reach extremely long ranges at low data-rates. It provides ultra-long range spread spectrum communication and high interference immunity whilst minimizing current consumption.
26 26  
27 -DDS75-LB (% style="color:blue" %)**supports BLE configure**(%%) and (% style="color:blue" %)**wireless OTA update**(%%) which make user easy to use.
27 +SW3L-LB (% style="color:blue" %)**supports BLE configure**(%%) and (% style="color:blue" %)**wireless OTA update**(%%) which make user easy to use.
28 28  
29 -DDS75-LB is powered by (% style="color:blue" %)**8500mAh Li-SOCI2 battery**(%%), it is designed for long term use up to 5 years.
29 +SW3L-LB is powered by (% style="color:blue" %)**8500mAh Li-SOCI2 battery**(%%), it is designed for long term use up to 5 years.
30 30  
31 -Each DDS75-LB is pre-load with a set of unique keys for LoRaWAN registrations, register these keys to local LoRaWAN server and it will auto connect after power on.
31 +Each SW3L-LB is pre-load with a set of unique keys for LoRaWAN registrations, register these keys to local LoRaWAN server and it will auto connect after power on.
32 32  
33 33  [[image:image-20230612170943-2.png||height="525" width="912"]]
34 34  
... ... @@ -39,47 +39,20 @@
39 39  * LoRaWAN 1.0.3 Class A
40 40  * Bands: CN470/EU433/KR920/US915/EU868/AS923/AU915/IN865
41 41  * Ultra-low power consumption
42 -* Distance Detection by Ultrasonic technology
43 -* Flat object range 280mm - 7500mm
44 -* Accuracy: ±(1cm+S*0.3%) (S: Distance)
45 -* Cable Length : 25cm
42 +* Upload water flow volume
43 +* Monitor water waste
44 +* AT Commands to change parameters
45 +* supports Datalog feature
46 46  * Support Bluetooth v5.1 and LoRaWAN remote configure
47 47  * Support wireless OTA update firmware
48 -* AT Commands to change parameters
48 +* Uplink on periodically and open/close event
49 49  * Downlink to change configure
50 -* IP66 Waterproof Enclosure
51 51  * 8500mAh Battery for long term use
52 52  
52 +
53 53  == 1.3 Specification ==
54 54  
55 55  
56 -(% style="color:#037691" %)**Rated environmental conditions:**
57 -
58 -(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:500px" %)
59 -|(% style="background-color:#d9e2f3; color:#0070c0; width:163px" %)**Item**|(% style="background-color:#d9e2f3; color:#0070c0; width:90px" %)(((
60 -**Minimum value**
61 -)))|(% style="background-color:#d9e2f3; color:#0070c0; width:70px" %)(((
62 -**Typical value**
63 -)))|(% style="background-color:#d9e2f3; color:#0070c0; width:87px" %)(((
64 -**Maximum value**
65 -)))|(% style="background-color:#d9e2f3; color:#0070c0; width:40px" %)**Unit**|(% style="background-color:#d9e2f3; color:#0070c0; width:50px" %)**Remarks**
66 -|(% style="width:174px" %)Storage temperature|(% style="width:86px" %)-25|(% style="width:66px" %)25|(% style="width:90px" %)80|(% style="width:48px" %)℃|(% style="width:203px" %)
67 -|(% style="width:174px" %)Storage humidity|(% style="width:86px" %) |(% style="width:66px" %)65%|(% style="width:90px" %)90%|(% style="width:48px" %)RH|(% style="width:203px" %)(1)
68 -|(% style="width:174px" %)Operating temperature|(% style="width:86px" %)-15|(% style="width:66px" %)25|(% style="width:90px" %)60|(% style="width:48px" %)℃|(% style="width:203px" %)
69 -|(% style="width:174px" %)Working humidity|(% style="width:86px" %)(((
70 -
71 -
72 -
73 -)))|(% style="width:66px" %)65%|(% style="width:90px" %)80%|(% style="width:48px" %)RH|(% style="width:203px" %)(1)
74 -
75 -(((
76 -(% style="color:red" %)**Remarks: (1) a. When the ambient temperature is 0-39 ℃, the maximum humidity is 90% (non-condensing);       **
77 -
78 -(% style="color:red" %)** b. When the ambient temperature is 40-50 ℃, the highest humidity is the highest humidity in the natural world at the current temperature (no condensation)**
79 -
80 -
81 -)))
82 -
83 83  (% style="color:#037691" %)**Common DC Characteristics:**
84 84  
85 85  * Supply Voltage: built in 8500mAh Li-SOCI2 battery , 2.5v ~~ 3.6v
... ... @@ -105,41 +105,25 @@
105 105  * Sleep Mode: 5uA @ 3.3v
106 106  * LoRa Transmit Mode: 125mA @ 20dBm, 82mA @ 14dBm
107 107  
108 -== 1.4 Effective measurement range Reference beam pattern ==
109 109  
82 +== 1.4 Applications ==
110 110  
111 -(% style="color:blue" %)**1. The tested object is a white cylindrical tube made of PVC, with a height of 100cm and a diameter of 7.5cm.**
112 112  
113 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDDS75%20-%20LoRaWAN%20Distance%20Detection%20Sensor%20User%20Manual/WebHome/1654852253176-749.png?rev=1.1||alt="1654852253176-749.png"]]
85 +* Flow Sensor application
86 +* Water Control
87 +* Toilet Flow Sensor
88 +* Monitor Waste water
114 114  
115 115  
116 -(% style="color:blue" %)**2. The object to be tested is a "corrugated cardboard box" perpendicular to the central axis of 0 °, and the length * width is 60cm * 50cm.**
91 +== 1.5 Sleep mode and working mode ==
117 117  
118 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDDS75%20-%20LoRaWAN%20Distance%20Detection%20Sensor%20User%20Manual/WebHome/1654852175653-550.png?rev=1.1||alt="1654852175653-550.png"]]
119 119  
120 -
121 -== 1.5 Applications ==
122 -
123 -
124 -* Horizontal distance measurement
125 -* Liquid level measurement
126 -* Parking management system
127 -* Object proximity and presence detection
128 -* Intelligent trash can management system
129 -* Robot obstacle avoidance
130 -* Automatic control
131 -* Sewer
132 -* Bottom water level monitoring
133 -
134 -== 1.6 Sleep mode and working mode ==
135 -
136 -
137 137  (% style="color:blue" %)**Deep Sleep Mode: **(%%)Sensor doesn't have any LoRaWAN activate. This mode is used for storage and shipping to save battery life.
138 138  
139 139  (% style="color:blue" %)**Working Mode:** (%%)In this mode, Sensor will work as LoRaWAN Sensor to Join LoRaWAN network and send out sensor data to server. Between each sampling/tx/rx periodically, sensor will be in IDLE mode), in IDLE mode, sensor has the same power consumption as Deep Sleep mode.
140 140  
141 141  
142 -== 1.7 Button & LEDs ==
99 +== 1.6 Button & LEDs ==
143 143  
144 144  
145 145  [[image:Main.User Manual for LoRaWAN End Nodes.D20-LBD22-LBD23-LB_LoRaWAN_Temperature_Sensor_User_Manual.WebHome@1675071855856-879.png]]
... ... @@ -158,12 +158,13 @@
158 158  )))
159 159  |(% style="width:167px" %)Fast press ACT 5 times.|(% style="width:117px" %)Deactivate Device|(% style="width:225px" %)(% style="color:red" %)**Red led**(%%) will solid on for 5 seconds. Means device is in Deep Sleep Mode.
160 160  
161 -== 1.8 BLE connection ==
162 162  
119 +== 1.7 BLE connection ==
163 163  
164 -DDS75-LB support BLE remote configure.
165 165  
122 +SW3L-LB support BLE remote configure.
166 166  
124 +
167 167  BLE can be used to configure the parameter of sensor or see the console output from sensor. BLE will be only activate on below case:
168 168  
169 169  * Press button to send an uplink
... ... @@ -173,13 +173,24 @@
173 173  If there is no activity connection on BLE in 60 seconds, sensor will shut down BLE module to enter low power mode.
174 174  
175 175  
176 -== 1.9 Pin Definitions ==
134 +== 1.8 Pin Definitions ==
177 177  
178 178  [[image:image-20230523174230-1.png]]
179 179  
180 180  
139 +== 1.9 Flow Sensor Spec ==
181 181  
182 182  
142 +(((
143 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:510px" %)
144 +|=(% style="width: 80px;background-color:#D9E2F3;color:#0070C0" %)**Model**|=(% style="width: 80px;background-color:#D9E2F3;color:#0070C0" %)**Probe**|=(% style="width: 80px;background-color:#D9E2F3;color:#0070C0" %)**Diameter**|=(% style="width: 80px;background-color:#D9E2F3;color:#0070C0" %)**Range**|=(% style="width: 80px;background-color:#D9E2F3;color:#0070C0" %)**Max Pressure**|=(% style="width: 110px;background-color:#D9E2F3;color:#0070C0" %)**Measure**
145 +|(% style="width:88px" %)SW3L-004|(% style="width:75px" %)DW-004|(% style="width:107px" %)G1/2" /DN15|(% style="width:101px" %)1~~30L/min|(% style="width:116px" %)≤ 2.0Mpa|(% style="width:124px" %)450 pulse = 1 L
146 +|(% style="width:88px" %)SW3L-006|(% style="width:75px" %)DW-006|(% style="width:107px" %)G3/4" /DN20|(% style="width:101px" %)1~~60L/min|(% style="width:116px" %)≤ 1.2Mpa|(% style="width:124px" %)390 pulse = 1 L
147 +|(% style="width:88px" %)SW3L-010|(% style="width:75px" %)DW-010|(% style="width:107px" %)G 1" /DN25|(% style="width:101px" %)2~~100L/min|(% style="width:116px" %)≤ 2.0Mpa|(% style="width:124px" %)64 pulse = 1 L
148 +)))
149 +
150 +
151 +
183 183  == 2.10 Mechanical ==
184 184  
185 185  
... ... @@ -192,24 +192,27 @@
192 192  [[image:Main.User Manual for LoRaWAN End Nodes.D20-LBD22-LBD23-LB_LoRaWAN_Temperature_Sensor_User_Manual.WebHome@1675143909447-639.png]]
193 193  
194 194  
195 -(% style="color:blue" %)**Probe Mechanical:**
164 +(% style="color:blue" %)**DW-004 Flow Sensor: diameter: G1/2” / DN15.  450 pulse = 1 L**
196 196  
166 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/SW3L%20LoRaWAN%20Outdoor%20Flow%20Sensor/WebHome/image-20220519091350-1.png?width=722&height=385&rev=1.1||alt="image-20220519091350-1.png"]]
197 197  
198 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDDS75%20-%20LoRaWAN%20Distance%20Detection%20Sensor%20User%20Manual/WebHome/image-20220610172003-1.png?rev=1.1||alt="image-20220610172003-1.png"]]
199 199  
169 +(% style="color:blue" %)**006: DW-006 Flow Sensor: diameter: G3/4” / DN20.  390 pulse = 1 L**
200 200  
201 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDDS75%20-%20LoRaWAN%20Distance%20Detection%20Sensor%20User%20Manual/WebHome/image-20220610172003-2.png?rev=1.1||alt="image-20220610172003-2.png"]]
171 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/SW3L%20LoRaWAN%20Outdoor%20Flow%20Sensor/WebHome/image-20220519091423-2.png?width=723&height=258&rev=1.1||alt="image-20220519091423-2.png"]]
202 202  
203 203  
204 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDDS75%20-%20LoRaWAN%20Distance%20Detection%20Sensor%20User%20Manual/WebHome/image-20220610172003-2.png?rev=1.1||alt="image-20220610172003-2.png"]]
174 +(% style="color:blue" %)**010: DW-010 Flow Sensor: diameter: G 1” / DN25. 64 pulse = 1 L**
205 205  
176 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/SW3L%20LoRaWAN%20Outdoor%20Flow%20Sensor/WebHome/image-20220519091423-3.png?width=724&height=448&rev=1.1||alt="image-20220519091423-3.png"]]
206 206  
207 -= 2. Configure DDS75-LB to connect to LoRaWAN network =
208 208  
179 += 2. Configure SW3L-LB to connect to LoRaWAN network =
180 +
209 209  == 2.1 How it works ==
210 210  
211 211  
212 -The DDS75-LB is configured as (% style="color:#037691" %)**LoRaWAN OTAA Class A**(%%) mode by default. It has OTAA keys to join LoRaWAN network. To connect a local LoRaWAN network, you need to input the OTAA keys in the LoRaWAN IoT server and press the button to activate the DDS75-LB. It will automatically join the network via OTAA and start to send the sensor value. The default uplink interval is 20 minutes.
184 +The SW3L-LB is configured as (% style="color:#037691" %)**LoRaWAN OTAA Class A**(%%) mode by default. It has OTAA keys to join LoRaWAN network. To connect a local LoRaWAN network, you need to input the OTAA keys in the LoRaWAN IoT server and press the button to activate the SW3L-LB. It will automatically join the network via OTAA and start to send the sensor value. The default uplink interval is 20 minutes.
213 213  
214 214  (% style="display:none" %) (%%)
215 215  
... ... @@ -223,9 +223,9 @@
223 223  [[image:image-20230612171032-3.png||height="492" width="855"]](% style="display:none" %)
224 224  
225 225  
226 -(% style="color:blue" %)**Step 1:**(%%) Create a device in TTN with the OTAA keys from DDS75-LB.
198 +(% style="color:blue" %)**Step 1:**(%%) Create a device in TTN with the OTAA keys from SW3L-LB.
227 227  
228 -Each DDS75-LB is shipped with a sticker with the default device EUI as below:
200 +Each SW3L-LB is shipped with a sticker with the default device EUI as below:
229 229  
230 230  [[image:image-20230426084152-1.png||alt="图片-20230426084152-1.png" height="233" width="502"]]
231 231  
... ... @@ -254,10 +254,10 @@
254 254  [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LSN50v2-S31-S31B%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20User%20Manual/WebHome/image-20220611161308-6.png?width=744&height=485&rev=1.1||alt="图片-20220611161308-6.png"]]
255 255  
256 256  
257 -(% style="color:blue" %)**Step 2:**(%%) Activate on DDS75-LB
229 +(% style="color:blue" %)**Step 2:**(%%) Activate on SW3L-LB
258 258  
259 259  
260 -Press the button for 5 seconds to activate the DDS75-LB.
232 +Press the button for 5 seconds to activate the SW3L-LB.
261 261  
262 262  (% style="color:green" %)**Green led**(%%) will fast blink 5 times, device will enter (% style="color:blue" %)**OTA mode**(%%) for 3 seconds. And then start to JOIN LoRaWAN network. (% style="color:green" %)**Green led**(%%) will solidly turn on for 5 seconds after joined in network.
263 263  
... ... @@ -264,167 +264,355 @@
264 264  After join success, it will start to upload messages to TTN and you can see the messages in the panel.
265 265  
266 266  
267 -== 2.3  ​Uplink Payload ==
239 +== 2.3 ​Uplink Payload ==
268 268  
241 +=== 2.3.1 Device Status, FPORT~=5 ===
269 269  
270 -(((
271 -DDS75-LB will uplink payload via LoRaWAN with below payload format: 
272 -)))
273 273  
274 -(((
275 -Uplink payload includes in total 8 bytes.
276 -)))
244 +Include device configure status. Once SW3L-LB Joined the network, it will uplink this message to the server. After that, SW3L-LB will uplink Device Status every 12 hours.
277 277  
278 -(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:510px" %)
279 -|=(% style="width: 62.5px;background-color:#D9E2F3;color:#0070C0" %)(((
280 -**Size(bytes)**
281 -)))|=(% style="width: 62.5px;background-color:#D9E2F3;color:#0070C0" %)**2**|=(% style="background-color:#D9E2F3;color:#0070C0" %)**2**|=(% style="background-color:#D9E2F3;color:#0070C0" %)1|=(% style="background-color:#D9E2F3;color:#0070C0" %)2|=(% style="background-color:#D9E2F3;color:#0070C0" %)**1**
282 -|(% style="width:62.5px" %)**Value**|(% style="width:62.5px" %)[[BAT>>||anchor="H2.3.1A0BatteryInfo"]]|(((
283 -[[Distance>>||anchor="H2.3.2A0Distance"]]
284 -(unit: mm)
285 -)))|[[Digital Interrupt (Optional)>>||anchor="H2.3.3A0InterruptPin"]]|(((
286 -[[Temperature (Optional )>>||anchor="H2.3.4A0DS18B20Temperaturesensor"]]
287 -)))|[[Sensor Flag>>||anchor="H2.3.5A0SensorFlag"]]
246 +Users can use the downlink command(**0x26 01**) to ask SW3L-LB to send device configure detail, include device configure status. SW3L-LB will uplink a payload via FPort=5 to server.
288 288  
289 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDDS75%20-%20LoRaWAN%20Distance%20Detection%20Sensor%20User%20Manual/WebHome/1654850511545-399.png?rev=1.1||alt="1654850511545-399.png"]]
248 +The Payload format is as below.
290 290  
291 291  
292 -=== 2.3.1  Battery Info ===
251 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %)
252 +|(% colspan="6" style="background-color:#d9e2f3; color:#0070c0" %)**Device Status (FPORT=5)**
253 +|(% style="width:103px" %)**Size (bytes)**|(% style="width:72px" %)**1**|**2**|(% style="width:91px" %)**1**|(% style="width:86px" %)**1**|(% style="width:44px" %)**2**
254 +|(% style="width:103px" %)**Value**|(% style="width:72px" %)Sensor Model|Firmware Version|(% style="width:91px" %)Frequency Band|(% style="width:86px" %)Sub-band|(% style="width:44px" %)BAT
293 293  
256 +Example parse in TTNv3
294 294  
295 -Check the battery voltage for DDS75-LB.
258 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/SW3L%20LoRaWAN%20Outdoor%20Flow%20Sensor/WebHome/1652925144491-755.png?width=732&height=139&rev=1.1||alt="1652925144491-755.png"]]
296 296  
260 +
261 +(% style="color:#037691" %)**Sensor Model**(%%): For SW3L-LB, this value is 0x11
262 +
263 +(% style="color:#037691" %)**Firmware Version**(%%): 0x0100, Means: v1.0.0 version
264 +
265 +(% style="color:#037691" %)**Frequency Band**:
266 +
267 +*0x01: EU868
268 +
269 +*0x02: US915
270 +
271 +*0x03: IN865
272 +
273 +*0x04: AU915
274 +
275 +*0x05: KZ865
276 +
277 +*0x06: RU864
278 +
279 +*0x07: AS923
280 +
281 +*0x08: AS923-1
282 +
283 +*0x09: AS923-2
284 +
285 +*0x0a: AS923-3
286 +
287 +*0x0b: CN470
288 +
289 +*0x0c: EU433
290 +
291 +*0x0d: KR920
292 +
293 +*0x0e: MA869
294 +
295 +
296 +(% style="color:#037691" %)**Sub-Band**:
297 +
298 +AU915 and US915:value 0x00 ~~ 0x08
299 +
300 +CN470: value 0x0B ~~ 0x0C
301 +
302 +Other Bands: Always 0x00
303 +
304 +
305 +(% style="color:#037691" %)**Battery Info**:
306 +
307 +Check the battery voltage.
308 +
297 297  Ex1: 0x0B45 = 2885mV
298 298  
299 299  Ex2: 0x0B49 = 2889mV
300 300  
301 301  
302 -=== 2.3.2  Distance ===
314 +=== 2.3.2 Sensor Configuration, FPORT~=4 ===
303 303  
304 304  
317 +SW3L-LB will only send this command after getting the downlink command (0x26 02) from the server.
318 +
319 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:510px" %)
320 +|(% style="background-color:#d9e2f3; color:#0070c0; width:70px" %) **Size(bytes)**|(% style="background-color:#d9e2f3; color:#0070c0; width:105px" %)**3**|(% style="background-color:#d9e2f3; color:#0070c0; width:60px" %)**1**|(% style="background-color:#d9e2f3; color:#0070c0; width:96px" %)**1**|(% style="background-color:#d9e2f3; color:#0070c0; width:105px" %)**2**|(% style="background-color:#d9e2f3; color:#0070c0; width:74px" %)**1**
321 +|**Value**|(% style="width:104px" %)TDC(unit:sec)|(% style="width:43px" %)N/A|(% style="width:91px" %)Stop Timer|(% style="width:100px" %)Alarm Timer|(% style="width:69px" %)Reserve
322 +
323 +* (% style="color:#037691" %)**TDC: (default: 0x0004B0)**
324 +
325 +Uplink interval for the total pulse count, default value is 0x0004B0 which is 1200 seconds = 20 minutes.
326 +
327 +
328 +* (% style="color:#037691" %)**STOP Duration & Alarm Timer**
329 +
330 +Shows the configure value of [[Alarm for continuously water flow>>||anchor="H3.3.4Alarmforcontinuouslywaterflow"]]
331 +
332 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/SW3L%20LoRaWAN%20Outdoor%20Flow%20Sensor/WebHome/image-20220519095747-2.png?width=723&height=113&rev=1.1||alt="image-20220519095747-2.png"]]
333 +
334 +
335 +=== 2.3.3 Water Flow Value, Uplink FPORT~=2 ===
336 +
337 +
305 305  (((
306 -Get the distance. Flat object range 280mm - 7500mm.
339 +SW3L-LB will send this uplink **after** Device Status once join the LoRaWAN network successfully. And SW3L-LB will:
307 307  )))
308 308  
309 309  (((
310 -For example, if the data you get from the register is 0x0B 0x05, the distance between the sensor and the measured object is(% style="color:#4472c4" %)** **
343 +periodically send this uplink every 20 minutes, this interval [[can be changed>>||anchor="H3.3.1SetTransmitIntervalTime"]].
344 +)))
311 311  
312 -(% style="color:#4472c4" %)**0B05(H) = 2821 (D) = 2821 mm.**
346 +(((
347 +Uplink Payload totals 11 bytes.
313 313  )))
314 314  
350 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:510px" %)
351 +|=(% colspan="6" style="width: 510px;background-color:#D9E2F3;color:#0070C0" %)**Water Flow Value,  FPORT=2**
352 +|(% style="width:60px" %)**Size(bytes)**|(% style="width:130px" %)**1**|(% style="width:130px" %)**4**|(% style="width:30px" %)**1**|(% style="width:50px" %)**1**|(% style="width:80px" %)**4**
353 +|(% style="width:110px" %)**Value**|(% style="width:81px" %)Calculate Flag & [[Alarm>>||anchor="H3.3.4Alarmforcontinuouslywaterflow"]]|(% style="width:95px" %)(((
354 +Total pulse Or Last Pulse
355 +)))|(% style="width:55px" %)MOD|(% style="width:115px" %)Reserve(0x01)|(% style="width:129px" %)[[Unix TimeStamp>>||anchor="H2.5.2UnixTimeStamp"]]
315 315  
316 -* If the sensor value is 0x0000, it means system doesn't detect ultrasonic sensor.
317 -* If the sensor value lower than 0x0118 (280mm), the sensor value will be invalid. All value lower than 280mm will be set to 0x0014(20mm) which means the value is invalid.
357 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:470px" %)
358 +|=(% colspan="4" style="width: 470px;background-color:#D9E2F3;color:#0070C0" %)**Status & Alarm field**
359 +|(% style="width:60px" %)**Size(bit)**|(% style="width:80px" %)**6**|(% style="width:310px" %)**1**|(% style="width:20px" %)**1**
360 +|(% style="width:88px" %)**Value**|(% style="width:117px" %)Calculate Flag|(% style="width:221px" %)Alarm: 0: No Alarm; 1: Alarm|(% style="width:64px" %)N/A
318 318  
362 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/SW3L%20LoRaWAN%20Outdoor%20Flow%20Sensor/WebHome/image-20220519095946-3.png?width=736&height=284&rev=1.1||alt="image-20220519095946-3.png"]]
319 319  
320 -=== 2.3.3  Interrupt Pin ===
321 321  
365 +* (((
366 +(% style="color:#037691" %)**Calculate Flag**
367 +)))
322 322  
323 -This data field shows if this packet is generated by interrupt or not. [[Click here>>||anchor="H3.3.2SetInterruptMode"]] for the hardware and software set up.
369 +(((
370 +The calculate flag is a user defined field, IoT server can use this flag to handle different meters with different pulse factors. For example, if there are 100 Flow Sensors, meters 1 ~~50 are 1 liter/pulse and meters 51 ~~ 100 has 1.5 liter/pulse.
371 +)))
324 324  
325 -**Example:**
373 +(((
374 +**Example: in the default payload:**
375 +)))
326 326  
327 -0x00: Normal uplink packet.
377 +* (((
378 +calculate flag=0: for SW3L-004 Flow Sensor: 450 pulse = 1 L
379 +)))
380 +* (((
381 +calculate flag=1: for SW3L-006 Flow Sensor: 390 pulse = 1 L
382 +)))
383 +* (((
384 +calculate flag=2: for SW3L-010 Flow Sensor: 64 pulse = 1 L
385 +)))
328 328  
329 -0x01: Interrupt Uplink Packet.
387 +(((
388 +Default value: 0. 
389 +)))
330 330  
391 +(((
392 +Range (6 bits): (b)000000 ~~ (b) 111111
331 331  
332 -=== 2.3.4  DS18B20 Temperature sensor ===
394 +If user use with a meter for example is 0.02L/pulse. To proper decode the correct value in server,
333 333  
396 +1) User can set the Calculate Flag of this sensor to 3.
334 334  
335 -This is optional, user can connect external DS18B20 sensor to the +3.3v, 1-wire and GND pin . and this field will report temperature.
398 +2) In server side, when a sensor data arrive, the decoder will check the value of Calculate Flag, It the value is 3, the total volume = 0.02 x Pulse Count.
399 +)))
336 336  
337 -**Example**:
401 +(((
402 +(% style="color:red" %)**NOTE: User need to set Calculate Flag to proper value before use Flow Sensor. Downlink or AT Command see: **(%%)Refer: [[Set Calculate Flag>>||anchor="H3.3.6Setthecalculateflag"]]
403 +)))
338 338  
339 -If payload is: 0105H:  (0105 & FC00 == 0), temp = 0105H /10 = 26.1 degree
405 +* (((
406 +(% style="color:#037691" %)**Alarm**
407 +)))
340 340  
341 -If payload is: FF3FH :  (FF3F & FC00 == 1) , temp = (FF3FH - 65536)/10 = -19.3 degrees.
409 +(((
410 +See [[Alarm for continuously water flow>>||anchor="H3.3.4Alarmforcontinuouslywaterflow"]]
411 +)))
342 342  
413 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/SW3L%20LoRaWAN%20Outdoor%20Flow%20Sensor/WebHome/image-20220519095946-4.png?width=724&height=65&rev=1.1||alt="image-20220519095946-4.png"]]
343 343  
344 -=== 2.3.5  Sensor Flag ===
345 345  
416 +* (((
417 +(% style="color:#037691" %)**Total pulse**
418 +)))
346 346  
347 347  (((
348 -0x01: Detect Ultrasonic Sensor
421 +Total pulse/counting since factory
349 349  )))
350 350  
351 351  (((
352 -0x00: No Ultrasonic Sensor
425 +Range (4 Bytes) : 0x00000000~~ 0xFFFFFFFF .
353 353  )))
354 354  
428 +* (((
429 +(% style="color:#037691" %)**Last Pulse**
430 +)))
355 355  
356 -=== 2.3.6  Decode payload in The Things Network ===
432 +(((
433 +Total pulse since last FPORT=2 uplink. (Default 20 minutes)
434 +)))
357 357  
436 +(((
437 +Range (4 Bytes) : 0x00000000~~ 0xFFFFFFFF .
438 +)))
358 358  
359 -While using TTN network, you can add the payload format to decode the payload.
440 +* (((
441 +(% style="color:#037691" %)**MOD: Default =0**
442 +)))
360 360  
361 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDDS75%20-%20LoRaWAN%20Distance%20Detection%20Sensor%20User%20Manual/WebHome/1654850829385-439.png?rev=1.1||alt="1654850829385-439.png"]]
444 +(((
445 +MOD=0 ~-~-> Uplink Total Pulse since factory
446 +)))
362 362  
363 -The payload decoder function for TTN V3 is here:
448 +(((
449 +MOD=1 ~-~-> Uplink total pulse since last FPORT=2 uplink.
450 +)))
364 364  
452 +* (((
453 +(% style="color:#037691" %)**Water Flow Value**
454 +)))
455 +
365 365  (((
366 -DDS75-LB TTN V3 Payload Decoder:  [[ttps:~~/~~/github.com/dragino/dragino-end-node-decoder>>https://github.com/dragino/dragino-end-node-decoder]]
457 +**Total Water Flow Volume = (Calculate Flag) x (Total Pulse)=9597/450=21.3L**
367 367  )))
368 368  
460 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/SW3L%20LoRaWAN%20Outdoor%20Flow%20Sensor/WebHome/image-20220519095946-5.png?width=727&height=50&rev=1.1||alt="image-20220519095946-5.png"]]
369 369  
370 -== 2.4  Uplink Interval ==
371 371  
463 +(((
464 +**Total Water Flow for TDC timer = (Calculate Flag) x (Last Pulse)=79/450=0.2L**
465 +)))
372 372  
373 -The DDS75-LB by default uplink the sensor data every 20 minutes. User can change this interval by AT Command or LoRaWAN Downlink Command. See this link: [[Change Uplink Interval>>||anchor="H3.3.1SetTransmitIntervalTime"]]
467 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/SW3L%20LoRaWAN%20Outdoor%20Flow%20Sensor/WebHome/image-20220519095946-6.png?width=733&height=43&rev=1.1||alt="image-20220519095946-6.png"]] ** **
374 374  
375 375  
376 -== 2. ​Show Data in DataCake IoT Server ==
470 +=== 2.3.4 Historical Water Flow Status, FPORT~=3 ===
377 377  
378 378  
379 379  (((
380 -[[DATACAKE>>url:https://datacake.co/]] provides a human friendly interface to show the sensor data, once we have data in TTN, we can use [[DATACAKE>>url:https://datacake.co/]] to connect to TTN and see the data in DATACAKE. Below are the steps:
474 +SW3L-LB stores sensor values and users can retrieve these history values via the [[downlink command>>||anchor="H2.5DatalogFeature"]].
381 381  )))
382 382  
477 +(((
478 +The historical payload includes one or multiplies entries and every entry has the same payload as Real-Time water flow status.
479 +)))
383 383  
481 +* (((
482 +Each data entry is 11 bytes and has the same structure as [[real time water flow status>>||anchor="H2.3.3A0WaterFlowValue2CUplinkFPORT3D2"]], to save airtime and battery, SW3L will send max bytes according to the current DR and Frequency bands.
483 +)))
484 +
384 384  (((
385 -(% style="color:blue" %)**Step 1**(%%)**: Be sure that your device is programmed and properly connected to the network at this time.**
486 +For example, in the US915 band, the max payload for different DR is:
386 386  )))
387 387  
388 388  (((
389 -(% style="color:blue" %)**Step 2**(%%)**: To configure the Application to forward data to DATACAKE you will need to add integration. To add the DATACAKE integration, perform the following steps:**
490 +(% style="color:blue" %)**a) DR0:**(%%) max is 11 bytes so one entry of data
390 390  )))
391 391  
493 +(((
494 +(% style="color:blue" %)**b) DR1:**(%%) max is 53 bytes so devices will upload 4 entries of data (total 44 bytes)
495 +)))
392 392  
393 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDDS75%20-%20LoRaWAN%20Distance%20Detection%20Sensor%20User%20Manual/WebHome/1654592790040-760.png?rev=1.1||alt="1654592790040-760.png"]]
497 +(((
498 +(% style="color:blue" %)**c) DR2:**(%%) total payload includes 11 entries of data
499 +)))
394 394  
501 +(((
502 +(% style="color:blue" %)**d) DR3:**(%%) total payload includes 22 entries of data.
503 +)))
395 395  
396 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDDS75%20-%20LoRaWAN%20Distance%20Detection%20Sensor%20User%20Manual/WebHome/1654592800389-571.png?rev=1.1||alt="1654592800389-571.png"]]
505 +(((
506 +If SW3L-LB doesn't have any data in the polling time. It will uplink 11 bytes of 0
507 +)))
397 397  
509 +(((
510 +(% style="color:#037691" %)**Downlink:**
511 +)))
398 398  
399 -(% style="color:blue" %)**Step 3**(%%)**: Create an account or log in Datacake.**
513 +(((
514 +0x31 62 46 B1 F0 62 46 B3 94 07
515 +)))
400 400  
401 -(% style="color:blue" %)**Step 4**(%%)**: Search the DDS75-LB and add DevEUI.**
517 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/SW3L%20LoRaWAN%20Outdoor%20Flow%20Sensor/WebHome/1652926690850-712.png?width=726&height=115&rev=1.1||alt="1652926690850-712.png"]]
402 402  
403 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDDS75%20-%20LoRaWAN%20Distance%20Detection%20Sensor%20User%20Manual/WebHome/1654851029373-510.png?rev=1.1||alt="1654851029373-510.png"]]
404 404  
520 +(((
521 +(% style="color:#037691" %)**Uplink:**
522 +)))
405 405  
406 -After added, the sensor data arrive TTN V3, it will also arrive and show in Datacake.
524 +(((
525 +00 00 01 00 00 00 00 62 46 B2 26 00 00 01 00 00 00 00 62 46 B2 5D 00 00 01 00 00 00 00 62 46 B2 99 00 00 01 00 00 00 00 62 46 B2 D5 00 00 01 00 00 01 15 62 46 B3 11 00 00 01 00 00 01 1F 62 46 B3 7E
526 +)))
407 407  
408 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDDS75%20-%20LoRaWAN%20Distance%20Detection%20Sensor%20User%20Manual/WebHome/image-20220610165129-11.png?width=1088&height=595&rev=1.1||alt="image-20220610165129-11.png"]]
528 +(((
529 +(% style="color:#037691" %)**Parsed Value:**
530 +)))
409 409  
532 +(((
533 +[Alarm, Calculate Flag, MOD, Total pulse or Last Pulse,** **Water Flow Value, TIME]
534 +)))
410 410  
411 411  
412 -== 2.6 Datalog Feature ==
537 +(((
538 +[FALSE,0,0,0,0.0,2022-04-01 08:04:54],
539 +)))
413 413  
541 +(((
542 +[FALSE,0,0,0,0.0,2022-04-01 08:05:49],
543 +)))
414 414  
415 -Datalog Feature is to ensure IoT Server can get all sampling data from Sensor even if the LoRaWAN network is down. For each sampling, DDS75-LB will store the reading for future retrieving purposes.
545 +(((
546 +[FALSE,0,0,0,0.0,2022-04-01 08:06:49],
547 +)))
416 416  
549 +(((
550 +[FALSE,0,0,0,0.0,2022-04-01 08:07:49],
551 +)))
417 417  
418 -=== 2.6.1 Ways to get datalog via LoRaWAN ===
553 +(((
554 +[FALSE,0,0,277,0.6,2022-04-01 08:08:49],
555 +)))
419 419  
557 +(((
558 +[FALSE,0,0,287,0.6,2022-04-01 08:10:38],
559 +)))
420 420  
421 -Set PNACKMD=1, DDS75-LB will wait for ACK for every uplink, when there is no LoRaWAN network,DDS75-LB will mark these records with non-ack messages and store the sensor data, and it will send all messages (10s interval) after the network recovery.
561 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/SW3L%20LoRaWAN%20Outdoor%20Flow%20Sensor/WebHome/1652926777796-267.png?width=724&height=279&rev=1.1||alt="1652926777796-267.png"]]
422 422  
563 +
564 +== 2.4 Payload Decoder file ==
565 +
566 +
567 +In TTN, use can add a custom payload so it shows friendly reading
568 +
569 +In the page (% style="color:#037691" %)**Applications ~-~-> Payload Formats ~-~-> Custom ~-~-> decoder**(%%) to add the decoder from: [[https:~~/~~/github.com/dragino/dragino-end-node-decoder>>https://github.com/dragino/dragino-end-node-decoder]]
570 +
571 +
572 +== 2.5 Datalog Feature ==
573 +
574 +
575 +Datalog Feature is to ensure IoT Server can get all sampling data from Sensor even if the LoRaWAN network is down. For each sampling, SW3L-LB will store the reading for future retrieving purposes.
576 +
577 +
578 +=== 2.5.1 Ways to get datalog via LoRaWAN ===
579 +
580 +
581 +Set PNACKMD=1, SW3L-LB will wait for ACK for every uplink, when there is no LoRaWAN network,SW3L-LB will mark these records with non-ack messages and store the sensor data, and it will send all messages (10s interval) after the network recovery.
582 +
423 423  * (((
424 -a) DDS75-LB will do an ACK check for data records sending to make sure every data arrive server.
584 +a) SW3L-LB will do an ACK check for data records sending to make sure every data arrive server.
425 425  )))
426 426  * (((
427 -b) DDS75-LB will send data in **CONFIRMED Mode** when PNACKMD=1, but DDS75-LB won't re-transmit the packet if it doesn't get ACK, it will just mark it as a NONE-ACK message. In a future uplink if DDS75-LB gets a ACK, DDS75-LB will consider there is a network connection and resend all NONE-ACK messages.
587 +b) SW3L-LB will send data in **CONFIRMED Mode** when PNACKMD=1, but SW3L-LB won't re-transmit the packet if it doesn't get ACK, it will just mark it as a NONE-ACK message. In a future uplink if SW3L-LB gets a ACK, SW3L-LB will consider there is a network connection and resend all NONE-ACK messages.
428 428  )))
429 429  
430 430  Below is the typical case for the auto-update datalog feature (Set PNACKMD=1)
... ... @@ -432,10 +432,10 @@
432 432  [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/WebHome/image-20220703111700-2.png?width=1119&height=381&rev=1.1||alt="图片-20220703111700-2.png" height="381" width="1119"]]
433 433  
434 434  
435 -=== 2.6.2 Unix TimeStamp ===
595 +=== 2.5.2 Unix TimeStamp ===
436 436  
437 437  
438 -DDS75-LB uses Unix TimeStamp format based on
598 +SW3L-LB uses Unix TimeStamp format based on
439 439  
440 440  [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/WebHome/image-20220523001219-11.png?width=627&height=97&rev=1.1||alt="图片-20220523001219-11.png" height="97" width="627"]]
441 441  
... ... @@ -449,17 +449,17 @@
449 449  So, we can use AT+TIMESTAMP=1611889405 or downlink 3060137afd00 to set the current time 2021 – Jan ~-~- 29 Friday 03:03:25
450 450  
451 451  
452 -=== 2.6.3 Set Device Time ===
612 +=== 2.5.3 Set Device Time ===
453 453  
454 454  
455 455  User need to set (% style="color:blue" %)**SYNCMOD=1**(%%) to enable sync time via MAC command.
456 456  
457 -Once DDS75-LB Joined LoRaWAN network, it will send the MAC command (DeviceTimeReq) and the server will reply with (DeviceTimeAns) to send the current time to DDS75-LB. If DDS75-LB fails to get the time from the server, DDS75-LB will use the internal time and wait for next time request (AT+SYNCTDC to set the time request period, default is 10 days).
617 +Once SW3L-LB Joined LoRaWAN network, it will send the MAC command (DeviceTimeReq) and the server will reply with (DeviceTimeAns) to send the current time to SW3L-LB. If SW3L-LB fails to get the time from the server, SW3L-LB will use the internal time and wait for next time request (AT+SYNCTDC to set the time request period, default is 10 days).
458 458  
459 459  (% style="color:red" %)**Note: LoRaWAN Server need to support LoRaWAN v1.0.3(MAC v1.0.3) or higher to support this MAC command feature, Chirpstack,TTN V3 v3 and loriot support but TTN V3 v2 doesn't support. If server doesn't support this command, it will through away uplink packet with this command, so user will lose the packet with time request for TTN V3 v2 if SYNCMOD=1.**
460 460  
461 461  
462 -=== 2.6.4 Poll sensor value ===
622 +=== 2.5.4 Poll sensor value ===
463 463  
464 464  
465 465  Users can poll sensor values based on timestamps. Below is the downlink command.
... ... @@ -482,24 +482,24 @@
482 482  )))
483 483  
484 484  (((
485 -Uplink Internal =5s,means DDS75-LB will send one packet every 5s. range 5~~255s.
645 +Uplink Internal =5s,means SW3L-LB will send one packet every 5s. range 5~~255s.
486 486  )))
487 487  
488 488  
489 -== 2.7 Frequency Plans ==
649 +== 2.6 Frequency Plans ==
490 490  
491 491  
492 -The DDS75-LB uses OTAA mode and below frequency plans by default. If user want to use it with different frequency plan, please refer the AT command sets.
652 +The SW3L-LB uses OTAA mode and below frequency plans by default. If user want to use it with different frequency plan, please refer the AT command sets.
493 493  
494 494  [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20Frequency%20Band/>>http://wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20Frequency%20Band/]]
495 495  
496 496  
497 -= 3. Configure DDS75-LB =
657 += 3. Configure SW3L-LB =
498 498  
499 499  == 3.1 Configure Methods ==
500 500  
501 501  
502 -DDS75-LB supports below configure method:
662 +SW3L-LB supports below configure method:
503 503  
504 504  * AT Command via Bluetooth Connection (**Recommended**): [[BLE Configure Instruction>>http://wiki.dragino.com/xwiki/bin/view/Main/BLE%20Bluetooth%20Remote%20Configure/]].
505 505  
... ... @@ -507,6 +507,7 @@
507 507  
508 508  * LoRaWAN Downlink.  Instruction for different platforms: See [[IoT LoRaWAN Server>>http://wiki.dragino.com/xwiki/bin/view/Main/]] section.
509 509  
670 +
510 510  == 3.2 General Commands ==
511 511  
512 512  
... ... @@ -521,10 +521,10 @@
521 521  [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/>>http://wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/]]
522 522  
523 523  
524 -== 3.3 Commands special design for DDS75-LB ==
685 +== 3.3 Commands special design for SW3L-LB ==
525 525  
526 526  
527 -These commands only valid for DDS75-LB, as below:
688 +These commands only valid for SW3L-LB, as below:
528 528  
529 529  
530 530  === 3.3.1 Set Transmit Interval Time ===
... ... @@ -569,9 +569,169 @@
569 569  Example 2: Downlink Payload: 0100003C  ~/~/ Set Transmit Interval (TDC) = 60 seconds
570 570  )))
571 571  
572 -=== 3.3.2 Set Interrupt Mode ===
573 573  
734 +=== 3.3.2 Quit AT Command ===
574 574  
736 +
737 +Feature: Quit AT Command mode, so user needs to input the password again before using AT Commands.
738 +
739 +(% style="color:blue" %)**AT Command: AT+DISAT**
740 +
741 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:452px" %)
742 +|=(% style="width: 155px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 198px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 99px;background-color:#D9E2F3;color:#0070C0" %)**Response**
743 +|(% style="width:155px" %)AT+DISAT|(% style="width:198px" %)Quit AT Commands mode|(% style="width:96px" %)OK
744 +
745 +(% style="color:blue" %)**Downlink Command:**
746 +
747 +No downlink command for this feature.
748 +
749 +
750 +=== 3.3.3 Get Device Status ===
751 +
752 +
753 +Send a LoRaWAN downlink to ask device send Alarm settings.
754 +
755 +(% style="color:blue" %)**Downlink Payload:  **(%%)0x26 01
756 +
757 +Sensor will upload Device Status via FPORT=5. See payload section for detail.
758 +
759 +
760 +=== 3.3.4 Alarm for continuously water flow ===
761 +
762 +
763 +(((
764 +This feature is to monitor and send Alarm for continuously water flow.
765 +)))
766 +
767 +(((
768 +Example case is for Toilet water monitoring, if some one push toilet button, the toilet will have water flow. If the toilet button has broken and can't returned to original state, the water flow will keep for hours or days which cause huge waste for water.
769 +)))
770 +
771 +(((
772 +To monitor this faulty and send alarm, there are two settings:
773 +)))
774 +
775 +* (((
776 +(% style="color:#4f81bd" %)**Stop Duration: Unit: Second**
777 +)))
778 +
779 +(((
780 +Default: 15s, If SW3L-LB didn't see any water flow in 15s, SW3L-LB will consider stop of water flow event.
781 +)))
782 +
783 +* (((
784 +(% style="color:#4f81bd" %)**Alarm Timer: Units: Minute; Default 0 minutes (means Alarm disable)**
785 +)))
786 +
787 +(((
788 +**Example:** 3 minutes, if SW3L-LB detect a start of water flow event and didn't detect a stop event within Alarm timer, SW3L-LB will send an Alarm to indicate a water flow abnormal alarm.
789 +)))
790 +
791 +(((
792 +So for example, If we set stop duration=15s and Alarm Timer=3minutes. If the toilet water flow continuously for more than 3 minutes, Sensor will send an alarm (in Confirmed MODE) to platform.
793 +)))
794 +
795 +(((
796 +(% style="color:red" %)**Note:** **After this alarm is send, sensor will consider a stop of water flow and count for another new event. So if water flow waste last for 1 hour, Sensor will keep sending alarm every 3 minutes.**
797 +)))
798 +
799 +(((
800 +(% style="color:#4f81bd" %)**AT Command**(%%) to configure:
801 +)))
802 +
803 +* (((
804 +AT+PTRIG=15,3  ~-~-> Set Stop duration: 15s, Alarm Timer: 3 minutes.
805 +)))
806 +
807 +* (((
808 +AT+ PTRIG=15,0  ~-~-> Default Value, disable water waste Alarm.
809 +)))
810 +
811 +(((
812 +(% style="color:#4f81bd" %)**Downlink Command**(%%) to configure: 
813 +)))
814 +
815 +(((
816 +Command: **0xAA aa bb cc**
817 +)))
818 +
819 +(((
820 +AA: Command Type Code
821 +)))
822 +
823 +(((
824 +aa: Stop duration
825 +)))
826 +
827 +(((
828 +bb cc: Alarm Timer
829 +)))
830 +
831 +(((
832 +If user send 0xAA 0F 00 03: equal to AT+PTRIG=15,3
833 +)))
834 +
835 +
836 +=== 3.3.5 Clear Flash Record ===
837 +
838 +
839 +Feature: Clear flash storage for data log feature.
840 +
841 +(% style="color:blue" %)**AT Command: AT+CLRDTA**
842 +
843 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:500px" %)
844 +|=(% style="width: 157px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 169px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 174px;background-color:#D9E2F3;color:#0070C0" %)**Response**
845 +|(% style="width:157px" %)AT+CLRDTA|(% style="width:169px" %)Clear flash storage for data log feature.|Clear all stored sensor data… OK
846 +
847 +(((
848 +(% style="color:blue" %)**Downlink Command:**
849 +)))
850 +
851 +(((
852 +* **Example**: 0xA301  ~/~/  Same as AT+CLRDTA
853 +)))
854 +
855 +
856 +
857 +=== 3.3.6 Set the calculate flag ===
858 +
859 +
860 +Feature: Set the calculate flag
861 +
862 +(% style="color:blue" %)**AT Command: AT+CALCFLAG**
863 +
864 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:461px" %)
865 +|=(% style="width: 158px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 193px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 110px;background-color:#D9E2F3;color:#0070C0" %)**Response**
866 +|(% style="width:158px" %)AT+CALCFLAG =1|(% style="width:192px" %)Set the calculate flag to 1.|(% style="width:109px" %)OK
867 +|(% style="width:158px" %)AT+CALCFLAG =2|(% style="width:192px" %)Set the calculate flag to 2.|(% style="width:109px" %)OK
868 +
869 +(% style="color:blue" %)**Downlink Command:**
870 +
871 +* **Example**: 0XA501  ~/~/  Same as AT+CALCFLAG =1
872 +
873 +
874 +=== 3.3.7 Set count number ===
875 +
876 +
877 +Feature: Manually set the count number
878 +
879 +(% style="color:blue" %)**AT Command: AT+SETCNT**
880 +
881 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:479px" %)
882 +|=(% style="width: 160px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 223px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 96px;background-color:#D9E2F3;color:#0070C0" %)**Response**
883 +|(% style="width:160px" %)AT+ SETCNT =0|(% style="width:221px" %)Set the count number to 0.|(% style="width:95px" %)OK
884 +|(% style="width:160px" %)AT+ SETCNT =100|(% style="width:221px" %)Set the count number to 100.|(% style="width:95px" %)OK
885 +
886 +(% style="color:blue" %)**Downlink Command:**
887 +
888 +* **Example**: 0xA6000001  ~/~/  Same as AT+ SETCNT =1
889 +
890 +* **Example**: 0xA6000064  ~/~/  Same as AT+ SETCNT =100
891 +
892 +
893 +=== 3.3.8 Set Interrupt Mode ===
894 +
895 +
575 575  Feature, Set Interrupt mode for PA8 of pin.
576 576  
577 577  When AT+INTMOD=0 is set, PA8 is used as a digital input port.
... ... @@ -603,100 +603,71 @@
603 603  
604 604  * Example 2: Downlink Payload: 06000003  ~/~/  Set the interrupt mode to rising edge trigger
605 605  
606 -= 4. Battery & Power Consumption =
607 607  
928 +=== 3.3.9 Set work mode ===
608 608  
609 -DDS75-LB use ER26500 + SPC1520 battery pack. See below link for detail information about the battery info and how to replace.
610 610  
611 -[[**Battery Info & Power Consumption Analyze**>>http://wiki.dragino.com/xwiki/bin/view/Main/How%20to%20calculate%20the%20battery%20life%20of%20Dragino%20sensors%3F/]] .
931 +Feature: Manually set the work mode
612 612  
613 613  
614 -= 5. OTA Firmware update =
934 +(% style="color:blue" %)**AT Command: AT+MOD**
615 615  
936 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:463px" %)
937 +|=(% style="width: 162px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 193px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 108px;background-color:#D9E2F3;color:#0070C0" %)**Response**
938 +|(% style="width:162px" %)AT+MOD=0|(% style="width:191px" %)Set the work mode to 0.|(% style="width:106px" %)OK
939 +|(% style="width:162px" %)AT+MOD=1|(% style="width:191px" %)Set the work mode to 1|(% style="width:106px" %)OK
616 616  
617 -(% class="wikigeneratedid" %)
618 -User can change firmware DDS75-LB to:
941 +(% style="color:blue" %)**Downlink Command:**
619 619  
620 -* Change Frequency band/ region.
943 +* **Example: **0x0A00  ~/~/  Same as AT+MOD=0
621 621  
622 -* Update with new features.
945 +* **Example:** 0x0A01  ~/~/  Same as AT+MOD=1
623 623  
624 -* Fix bugs.
625 625  
626 -Firmware and changelog can be downloaded from : **[[Firmware download link>>url:https://www.dropbox.com/sh/7la95mae0fn03xe/AACtzs-32m22TLb75B-iIr-Qa?dl=0]]**
948 += 4. Battery & Power Consumption =
627 627  
628 -Methods to Update Firmware:
629 629  
630 -* (Recommanded way) OTA firmware update via wireless:  [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/Firmware%20OTA%20Update%20for%20Sensors/>>url:http://wiki.dragino.com/xwiki/bin/view/Main/Firmware%20OTA%20Update%20for%20Sensors/]]
951 +SW3L-LB use ER26500 + SPC1520 battery pack. See below link for detail information about the battery info and how to replace.
631 631  
632 -* Update through UART TTL interface: **[[Instruction>>url:http://wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H1.LoRaSTv4baseHardware]]**.
953 +[[**Battery Info & Power Consumption Analyze**>>http://wiki.dragino.com/xwiki/bin/view/Main/How%20to%20calculate%20the%20battery%20life%20of%20Dragino%20sensors%3F/]] .
633 633  
634 -= 6. FAQ =
635 635  
636 -== 6. What is the frequency plan for DDS75-LB? ==
956 += 5. OTA Firmware update =
637 637  
638 638  
639 -DDS75-LB use the same frequency as other Dragino products. User can see the detail from this link:  [[Introduction>>doc:Main.End Device Frequency Band.WebHome||anchor="H1.Introduction"]]
959 +(% class="wikigeneratedid" %)
960 +User can change firmware SW3L-LB to:
640 640  
962 +* Change Frequency band/ region.
641 641  
642 -== 6.2  Can I use DDS75-LB in condensation environment? ==
964 +* Update with new features.
643 643  
966 +* Fix bugs.
644 644  
645 -DDS75-LB is not suitable to be used in condensation environment. Condensation on the DDS75-LB probe will affect the reading and always got 0.
968 +Firmware and changelog can be downloaded from : **[[Firmware download link>>url:https://www.dropbox.com/sh/kwqv57tp6pejias/AAAopYMATh1GM6fZ-VRCLrpDa?dl=0]]**
646 646  
970 +Methods to Update Firmware:
647 647  
648 -= 7.  Trouble Shooting =
972 +* (Recommanded way) OTA firmware update via wireless:   [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/Firmware%20OTA%20Update%20for%20Sensors/>>url:http://wiki.dragino.com/xwiki/bin/view/Main/Firmware%20OTA%20Update%20for%20Sensors/]]
649 649  
650 -== 7.1  Why I can't join TTN V3 in US915 / AU915 bands? ==
974 +* Update through UART TTL interface. **[[Instruction>>url:http://wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H1.LoRaSTv4baseHardware]]**.
651 651  
652 652  
653 -It is due to channel mapping. Please see below link:  [[Frequency band>>doc:Main.LoRaWAN Communication Debug.WebHome||anchor="H2.NoticeofUS9152FCN4702FAU915Frequencyband"]]
977 += 6. FAQ =
654 654  
979 +== 6.1  AT Commands input doesn't work ==
655 655  
656 -== 7.2  AT Command input doesn't work ==
657 657  
982 +In the case if user can see the console output but can't type input to the device. Please check if you already include the (% style="color:green" %)**ENTER**(%%) while sending out the command. Some serial tool doesn't send (% style="color:green" %)**ENTER**(%%) while press the send key, user need to add ENTER in their string.
658 658  
659 -In the case if user can see the console output but can't type input to the device. Please check if you already include the (% style="color:blue" %)**ENTER**(%%) while sending out the command. Some serial tool doesn't send (% style="color:blue" %)**ENTER**(%%) while press the send key, user need to add ENTER in their string.
660 660  
985 += 7. Order Info =
661 661  
662 -== 7.3  Why does the sensor reading show 0 or "No sensor" ==
663 663  
988 +Part Number: (% style="color:blue" %)**SW3L-LB-XXX-YYY**
664 664  
665 -~1. The measurement object is very close to the sensor, but in the blind spot of the sensor.
990 +(% style="color:red" %)**XXX**(%%): The default frequency band
666 666  
667 -2. Sensor wiring is disconnected
668 -
669 -3. Not using the correct decoder
670 -
671 -
672 -== 7.4  Abnormal readings The gap between multiple readings is too large or the gap between the readings and the actual value is too large ==
673 -
674 -
675 -1) Please check if there is something on the probe affecting its measurement (condensed water, volatile oil, etc.)
676 -
677 -2) Does it change with temperature, temperature will affect its measurement
678 -
679 -3) If abnormal data occurs, you can turn on DEBUG mode, Please use downlink or AT COMMAN to enter DEBUG mode.
680 -
681 -downlink command: (% style="color:blue" %)**F1 01**(%%), AT command: (% style="color:blue" %)**AT+DDEBUG=1**
682 -
683 -4) After entering the debug mode, it will send 20 pieces of data at a time, and you can send its uplink to us for analysis
684 -
685 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDDS75%20-%20LoRaWAN%20Distance%20Detection%20Sensor%20User%20Manual/WebHome/image-20230113135125-2.png?width=1057&height=136&rev=1.1||alt="image-20230113135125-2.png"]]
686 -
687 -
688 -Its original payload will be longer than other data. Even though it is being parsed, it can be seen that it is abnormal data.
689 -
690 -Please send the data to us for check.
691 -
692 -
693 -= 8. Order Info =
694 -
695 -
696 -Part Number: (% style="color:blue" %)**DDS75-LB-XXX**
697 -
698 -(% style="color:red" %)**XXX**(%%): **The default frequency band**
699 -
700 700  * (% style="color:red" %)**AS923**(%%): LoRaWAN AS923 band
701 701  
702 702  * (% style="color:red" %)**AU915**(%%): LoRaWAN AU915 band
... ... @@ -713,13 +713,43 @@
713 713  
714 714  * (% style="color:red" %)**CN470**(%%): LoRaWAN CN470 band
715 715  
1008 +(((
1009 +(% style="color:blue" %)**YYY**(%%): Flow Sensor Model:
1010 +)))
716 716  
717 -= 9. ​Packing Info =
1012 +(((
1013 + **004:** DW-004 Flow Sensor: diameter: G1/2” / DN15.  450 pulse = 1 L
1014 +)))
718 718  
1016 +(((
1017 + **006:** DW-006 Flow Sensor: diameter: G3/4” / DN20. 390 pulse = 1 L
1018 +)))
719 719  
1020 +(((
1021 + **010:** DW-010 Flow Sensor: diameter: G 1” / DN25. 64 pulse = 1 L
1022 +)))
1023 +
1024 +* (((
1025 +calculate flag=0: for SW3L-004 Flow Sensor: 450 pulse = 1 L
1026 +)))
1027 +
1028 +* (((
1029 +calculate flag=1: for SW3L-006 Flow Sensor: 390 pulse = 1 L
1030 +)))
1031 +
1032 +* (((
1033 +calculate flag=2: for SW3L-010 Flow Sensor: 64  pulse = 1 L
1034 +
1035 +
1036 +
1037 +)))
1038 +
1039 += 8. ​Packing Info =
1040 +
1041 +
720 720  (% style="color:#037691" %)**Package Includes**:
721 721  
722 -* DDS75-LB LoRaWAN Distance Detection Sensor x 1
1044 +* SW3L-LB LoRaWAN Flow Sensor
723 723  
724 724  (% style="color:#037691" %)**Dimension and weight**:
725 725  
... ... @@ -732,7 +732,7 @@
732 732  * Weight / pcs : g
733 733  
734 734  
735 -= 10. Support =
1057 += 9. Support =
736 736  
737 737  
738 738  * Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule.