Changes for page DS20L -- LoRaWAN Smart Distance Detector User Manual 01
Last modified by Mengting Qiu on 2023/12/14 11:15
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -22,13 +22,13 @@ 22 22 23 23 It detects the distance(% style="color:blue" %)** between the measured object and the sensor**(%%), and uploads the value via wireless to LoRaWAN IoT Server. 24 24 25 -The LoRa wireless technology used in DDS75-LB allows device to send data and reach extremely long ranges at low data-rates. It provides ultra-long range spread spectrum communication and high interference immunity whilst minimizing current consumption.25 +The LoRa wireless technology used in SW3L-LB allows device to send data and reach extremely long ranges at low data-rates. It provides ultra-long range spread spectrum communication and high interference immunity whilst minimizing current consumption. 26 26 27 - DDS75-LB (% style="color:blue" %)**supports BLE configure**(%%) and (% style="color:blue" %)**wireless OTA update**(%%) which make user easy to use.27 +SW3L-LB (% style="color:blue" %)**supports BLE configure**(%%) and (% style="color:blue" %)**wireless OTA update**(%%) which make user easy to use. 28 28 29 - DDS75-LB is powered by (% style="color:blue" %)**8500mAh Li-SOCI2 battery**(%%), it is designed for long term use up to 5 years.29 +SW3L-LB is powered by (% style="color:blue" %)**8500mAh Li-SOCI2 battery**(%%), it is designed for long term use up to 5 years. 30 30 31 -Each DDS75-LB is pre-load with a set of unique keys for LoRaWAN registrations, register these keys to local LoRaWAN server and it will auto connect after power on.31 +Each SW3L-LB is pre-load with a set of unique keys for LoRaWAN registrations, register these keys to local LoRaWAN server and it will auto connect after power on. 32 32 33 33 [[image:image-20230612170943-2.png||height="525" width="912"]] 34 34 ... ... @@ -73,9 +73,9 @@ 73 73 )))|(% style="width:66px" %)65%|(% style="width:90px" %)80%|(% style="width:48px" %)RH|(% style="width:203px" %)(1) 74 74 75 75 ((( 76 - (% style="color:red" %)**Remarks: (1) a. When the ambient temperature is 0-39 ℃, the maximum humidity is 90% (non-condensing); **76 +**Remarks: (1) a. When the ambient temperature is 0-39 ℃, the maximum humidity is 90% (non-condensing); ** 77 77 78 - (% style="color:red" %)** b. When the ambient temperature is 40-50 ℃, the highest humidity is the highest humidity in the natural world at the current temperature (no condensation)**78 +**~ b. When the ambient temperature is 40-50 ℃, the highest humidity is the highest humidity in the natural world at the current temperature (no condensation)** 79 79 80 80 81 81 ))) ... ... @@ -108,12 +108,12 @@ 108 108 == 1.4 Effective measurement range Reference beam pattern == 109 109 110 110 111 - (% style="color:blue" %)**1. The tested object is a white cylindrical tube made of PVC, with a height of 100cm and a diameter of 7.5cm.**111 +**~1. The tested object is a white cylindrical tube made of PVC, with a height of 100cm and a diameter of 7.5cm.** 112 112 113 113 [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDDS75%20-%20LoRaWAN%20Distance%20Detection%20Sensor%20User%20Manual/WebHome/1654852253176-749.png?rev=1.1||alt="1654852253176-749.png"]] 114 114 115 115 116 - (% style="color:blue" %)**2. The object to be tested is a "corrugated cardboard box" perpendicular to the central axis of 0 °, and the length * width is 60cm * 50cm.**116 +**2. The object to be tested is a "corrugated cardboard box" perpendicular to the central axis of 0 °, and the length * width is 60cm * 50cm.** 117 117 118 118 [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDDS75%20-%20LoRaWAN%20Distance%20Detection%20Sensor%20User%20Manual/WebHome/1654852175653-550.png?rev=1.1||alt="1654852175653-550.png"]] 119 119 ... ... @@ -178,8 +178,8 @@ 178 178 [[image:image-20230523174230-1.png]] 179 179 180 180 181 +== == 181 181 182 - 183 183 == 2.10 Mechanical == 184 184 185 185 ... ... @@ -192,7 +192,7 @@ 192 192 [[image:Main.User Manual for LoRaWAN End Nodes.D20-LBD22-LBD23-LB_LoRaWAN_Temperature_Sensor_User_Manual.WebHome@1675143909447-639.png]] 193 193 194 194 195 - (% style="color:blue" %)**Probe Mechanical:**195 +**Probe Mechanical:** 196 196 197 197 198 198 [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDDS75%20-%20LoRaWAN%20Distance%20Detection%20Sensor%20User%20Manual/WebHome/image-20220610172003-1.png?rev=1.1||alt="image-20220610172003-1.png"]] ... ... @@ -268,13 +268,20 @@ 268 268 269 269 270 270 ((( 271 +((( 271 271 DDS75-LB will uplink payload via LoRaWAN with below payload format: 272 272 ))) 273 273 274 274 ((( 275 -Uplink payload includes in total 8 bytes. 276 +Uplink payload includes in total 4 bytes. 277 +Payload for firmware version v1.1.4. . Before v1.1.3, there is on two fields: BAT and Distance 276 276 ))) 279 +))) 277 277 281 +((( 282 + 283 +))) 284 + 278 278 (% border="1" cellspacing="5" style="background-color:#f2f2f2; width:510px" %) 279 279 |=(% style="width: 62.5px;background-color:#D9E2F3;color:#0070C0" %)((( 280 280 **Size(bytes)** ... ... @@ -314,13 +314,12 @@ 314 314 315 315 316 316 * If the sensor value is 0x0000, it means system doesn't detect ultrasonic sensor. 317 -* If the sensor value lower than 0x0118 (280mm), the sensor value will be invalid. All value lower than 280mm will be set to 0x0014(20mm) which means the value is invalid.324 +* If the sensor value lower than 0x0118 (280mm), the sensor value will be invalid. Since v1.1.4, all value lower than 280mm will be set to 0x0014(20mm) which means the value is invalid. 318 318 319 - 320 320 === 2.3.3 Interrupt Pin === 321 321 322 322 323 -This data field shows if this packet is generated by interrupt or not. [[Click here>>||anchor="H3.3 .2SetInterruptMode"]] for the hardware and software set up.329 +This data field shows if this packet is generated by interrupt or not. [[Click here>>||anchor="H3.3A0SetInterruptMode"]] for the hardware and software set up. 324 324 325 325 **Example:** 326 326 ... ... @@ -340,7 +340,9 @@ 340 340 341 341 If payload is: FF3FH : (FF3F & FC00 == 1) , temp = (FF3FH - 65536)/10 = -19.3 degrees. 342 342 349 +(% style="color:red" %)**Note: DS18B20 feature is supported in the hardware version > v1.3 which made since early of 2021.** 343 343 351 + 344 344 === 2.3.5 Sensor Flag === 345 345 346 346 ... ... @@ -370,7 +370,7 @@ 370 370 == 2.4 Uplink Interval == 371 371 372 372 373 -The DDS75-LB by default uplink the sensor data every 20 minutes. User can change this interval by AT Command or LoRaWAN Downlink Command. See this link: [[Change Uplink Interval>>||anchor="H 3.3.1SetTransmitIntervalTime"]]381 +The DDS75-LB by default uplink the sensor data every 20 minutes. User can change this interval by AT Command or LoRaWAN Downlink Command. See this link: [[Change Uplink Interval>>doc:Main.End Device AT Commands and Downlink Command.WebHome||anchor="H4.1ChangeUplinkInterval"]] 374 374 375 375 376 376 == 2.5 Show Data in DataCake IoT Server == ... ... @@ -415,19 +415,19 @@ 415 415 == 2.6 Datalog Feature == 416 416 417 417 418 -Datalog Feature is to ensure IoT Server can get all sampling data from Sensor even if the LoRaWAN network is down. For each sampling, DDS75-LB will store the reading for future retrieving purposes.426 +Datalog Feature is to ensure IoT Server can get all sampling data from Sensor even if the LoRaWAN network is down. For each sampling, SW3L-LB will store the reading for future retrieving purposes. 419 419 420 420 421 421 === 2.6.1 Ways to get datalog via LoRaWAN === 422 422 423 423 424 -Set PNACKMD=1, DDS75-LB will wait for ACK for every uplink, when there is no LoRaWAN network,DDS75-LB will mark these records with non-ack messages and store the sensor data, and it will send all messages (10s interval) after the network recovery.432 +Set PNACKMD=1, SW3L-LB will wait for ACK for every uplink, when there is no LoRaWAN network,SW3L-LB will mark these records with non-ack messages and store the sensor data, and it will send all messages (10s interval) after the network recovery. 425 425 426 426 * ((( 427 -a) DDS75-LB will do an ACK check for data records sending to make sure every data arrive server.435 +a) SW3L-LB will do an ACK check for data records sending to make sure every data arrive server. 428 428 ))) 429 429 * ((( 430 -b) DDS75-LB will send data in **CONFIRMED Mode** when PNACKMD=1, butDDS75-LB won't re-transmit the packet if it doesn't get ACK, it will just mark it as a NONE-ACK message. In a future uplink ifDDS75-LB gets a ACK,DDS75-LB will consider there is a network connection and resend all NONE-ACK messages.438 +b) SW3L-LB will send data in **CONFIRMED Mode** when PNACKMD=1, but SW3L-LB won't re-transmit the packet if it doesn't get ACK, it will just mark it as a NONE-ACK message. In a future uplink if SW3L-LB gets a ACK, SW3L-LB will consider there is a network connection and resend all NONE-ACK messages. 431 431 ))) 432 432 433 433 Below is the typical case for the auto-update datalog feature (Set PNACKMD=1) ... ... @@ -438,7 +438,7 @@ 438 438 === 2.6.2 Unix TimeStamp === 439 439 440 440 441 - DDS75-LB uses Unix TimeStamp format based on449 +SW3L-LB uses Unix TimeStamp format based on 442 442 443 443 [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/WebHome/image-20220523001219-11.png?width=627&height=97&rev=1.1||alt="图片-20220523001219-11.png" height="97" width="627"]] 444 444 ... ... @@ -457,7 +457,7 @@ 457 457 458 458 User need to set (% style="color:blue" %)**SYNCMOD=1**(%%) to enable sync time via MAC command. 459 459 460 -Once DDS75-LB Joined LoRaWAN network, it will send the MAC command (DeviceTimeReq) and the server will reply with (DeviceTimeAns) to send the current time toDDS75-LB. IfDDS75-LB fails to get the time from the server,DDS75-LB will use the internal time and wait for next time request (AT+SYNCTDC to set the time request period, default is 10 days).468 +Once SW3L-LB Joined LoRaWAN network, it will send the MAC command (DeviceTimeReq) and the server will reply with (DeviceTimeAns) to send the current time to SW3L-LB. If SW3L-LB fails to get the time from the server, SW3L-LB will use the internal time and wait for next time request (AT+SYNCTDC to set the time request period, default is 10 days). 461 461 462 462 (% style="color:red" %)**Note: LoRaWAN Server need to support LoRaWAN v1.0.3(MAC v1.0.3) or higher to support this MAC command feature, Chirpstack,TTN V3 v3 and loriot support but TTN V3 v2 doesn't support. If server doesn't support this command, it will through away uplink packet with this command, so user will lose the packet with time request for TTN V3 v2 if SYNCMOD=1.** 463 463 ... ... @@ -485,7 +485,7 @@ 485 485 ))) 486 486 487 487 ((( 488 -Uplink Internal =5s,means DDS75-LB will send one packet every 5s. range 5~~255s.496 +Uplink Internal =5s,means SW3L-LB will send one packet every 5s. range 5~~255s. 489 489 ))) 490 490 491 491 ... ... @@ -492,17 +492,17 @@ 492 492 == 2.7 Frequency Plans == 493 493 494 494 495 -The DDS75-LB uses OTAA mode and below frequency plans by default. If user want to use it with different frequency plan, please refer the AT command sets.503 +The SW3L-LB uses OTAA mode and below frequency plans by default. If user want to use it with different frequency plan, please refer the AT command sets. 496 496 497 497 [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20Frequency%20Band/>>http://wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20Frequency%20Band/]] 498 498 499 499 500 -= 3. Configure DDS75-LB =508 += 3. Configure SW3L-LB = 501 501 502 502 == 3.1 Configure Methods == 503 503 504 504 505 - DDS75-LB supports below configure method:513 +SW3L-LB supports below configure method: 506 506 507 507 * AT Command via Bluetooth Connection (**Recommended**): [[BLE Configure Instruction>>http://wiki.dragino.com/xwiki/bin/view/Main/BLE%20Bluetooth%20Remote%20Configure/]]. 508 508 ... ... @@ -524,10 +524,10 @@ 524 524 [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/>>http://wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/]] 525 525 526 526 527 -== 3.3 Commands special design for DDS75-LB ==535 +== 3.3 Commands special design for SW3L-LB == 528 528 529 529 530 -These commands only valid for DDS75-LB, as below:538 +These commands only valid for SW3L-LB, as below: 531 531 532 532 533 533 === 3.3.1 Set Transmit Interval Time === ... ... @@ -572,135 +572,259 @@ 572 572 Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds 573 573 ))) 574 574 575 -=== 3.3.2 Set InterruptMode===583 +=== 3.3.2 Quit AT Command === 576 576 577 577 578 -Feature ,SetInterruptmodeforPA8of pin.586 +Feature: Quit AT Command mode, so user needs to input the password again before using AT Commands. 579 579 580 - WhenAT+INTMOD=0 isset, PA8 isusedasaigitalinput port.588 +(% style="color:blue" %)**AT Command: AT+DISAT** 581 581 582 -(% style="color:blue" %)**AT Command: AT+INTMOD** 590 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:452px" %) 591 +|=(% style="width: 155px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 198px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 99px;background-color:#D9E2F3;color:#0070C0" %)**Response** 592 +|(% style="width:155px" %)AT+DISAT|(% style="width:198px" %)Quit AT Commands mode|(% style="width:96px" %)OK 583 583 584 -(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %) 585 -|=(% style="width: 155px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 197px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 158px;background-color:#D9E2F3;color:#0070C0" %)**Response** 586 -|(% style="width:154px" %)AT+INTMOD=?|(% style="width:196px" %)Show current interrupt mode|(% style="width:157px" %)((( 587 -0 588 -OK 589 -the mode is 0 =Disable Interrupt 594 +(% style="color:blue" %)**Downlink Command:** 595 + 596 +No downlink command for this feature. 597 + 598 + 599 +=== 3.3.3 Get Device Status === 600 + 601 + 602 +Send a LoRaWAN downlink to ask device send Alarm settings. 603 + 604 +(% style="color:blue" %)**Downlink Payload: **(%%)0x26 01 605 + 606 +Sensor will upload Device Status via FPORT=5. See payload section for detail. 607 + 608 + 609 +=== 3.3.4 Alarm for continuously water flow === 610 + 611 + 612 +((( 613 +This feature is to monitor and send Alarm for continuously water flow. 590 590 ))) 591 -|(% style="width:154px" %)AT+INTMOD=2|(% style="width:196px" %)((( 592 -Set Transmit Interval 593 -0. (Disable Interrupt), 594 -~1. (Trigger by rising and falling edge) 595 -2. (Trigger by falling edge) 596 -3. (Trigger by rising edge) 597 -)))|(% style="width:157px" %)OK 598 598 599 -(% style="color:blue" %)**Downlink Command: 0x06** 616 +((( 617 +Example case is for Toilet water monitoring, if some one push toilet button, the toilet will have water flow. If the toilet button has broken and can't returned to original state, the water flow will keep for hours or days which cause huge waste for water. 618 +))) 600 600 601 -Format: Command Code (0x06) followed by 3 bytes. 620 +((( 621 +To monitor this faulty and send alarm, there are two settings: 622 +))) 602 602 603 -This means that the interrupt mode of the end node is set to 0x000003=3 (rising edge trigger), and the type code is 06. 624 +* ((( 625 +(% style="color:#4f81bd" %)**Stop Duration: Unit: Second** 626 +))) 604 604 605 -* Example 1: Downlink Payload: 06000000 ~/~/ Turn off interrupt mode 628 +((( 629 +Default: 15s, If SW3L-LB didn't see any water flow in 15s, SW3L-LB will consider stop of water flow event. 630 +))) 606 606 607 -* Example 2: Downlink Payload: 06000003 ~/~/ Set the interrupt mode to rising edge trigger 632 +* ((( 633 +(% style="color:#4f81bd" %)**Alarm Timer: Units: Minute; Default 0 minutes (means Alarm disable)** 634 +))) 608 608 609 -= 4. Battery & Power Consumption = 636 +((( 637 +**Example:** 3 minutes, if SW3L-LB detect a start of water flow event and didn't detect a stop event within Alarm timer, SW3L-LB will send an Alarm to indicate a water flow abnormal alarm. 638 +))) 610 610 640 +((( 641 +So for example, If we set stop duration=15s and Alarm Timer=3minutes. If the toilet water flow continuously for more than 3 minutes, Sensor will send an alarm (in Confirmed MODE) to platform. 642 +))) 611 611 612 -DDS75-LB use ER26500 + SPC1520 battery pack. See below link for detail information about the battery info and how to replace. 644 +((( 645 +(% style="color:red" %)**Note:** **After this alarm is send, sensor will consider a stop of water flow and count for another new event. So if water flow waste last for 1 hour, Sensor will keep sending alarm every 3 minutes.** 646 +))) 613 613 614 -[[**Battery Info & Power Consumption Analyze**>>http://wiki.dragino.com/xwiki/bin/view/Main/How%20to%20calculate%20the%20battery%20life%20of%20Dragino%20sensors%3F/]] . 648 +((( 649 +(% style="color:#4f81bd" %)**AT Command**(%%) to configure: 650 +))) 615 615 652 +* ((( 653 +AT+PTRIG=15,3 ~-~-> Set Stop duration: 15s, Alarm Timer: 3 minutes. 654 +))) 616 616 617 -= 5. OTA Firmware update = 656 +* ((( 657 +AT+ PTRIG=15,0 ~-~-> Default Value, disable water waste Alarm. 658 +))) 618 618 660 +((( 661 +(% style="color:#4f81bd" %)**Downlink Command**(%%) to configure: 662 +))) 619 619 620 -(% class="wikigeneratedid" %) 621 -User can change firmware DDS75-LB to: 664 +((( 665 +Command: **0xAA aa bb cc** 666 +))) 622 622 623 -* Change Frequency band/ region. 668 +((( 669 +AA: Command Type Code 670 +))) 624 624 625 -* Update with new features. 672 +((( 673 +aa: Stop duration 674 +))) 626 626 627 -* Fix bugs. 676 +((( 677 +bb cc: Alarm Timer 678 +))) 628 628 629 -Firmware and changelog can be downloaded from : **[[Firmware download link>>url:https://www.dropbox.com/sh/7la95mae0fn03xe/AACtzs-32m22TLb75B-iIr-Qa?dl=0]]** 680 +((( 681 +If user send 0xAA 0F 00 03: equal to AT+PTRIG=15,3 682 +))) 630 630 631 -Methods to Update Firmware: 632 632 633 - *(Recommandedway) OTA firmwareupdate via wireless: [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/Firmware%20OTA%20Update%20for%20Sensors/>>url:http://wiki.dragino.com/xwiki/bin/view/Main/Firmware%20OTA%20Update%20for%20Sensors/]]685 +=== 3.3.5 Clear Flash Record === 634 634 635 -* Update through UART TTL interface: **[[Instruction>>url:http://wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H1.LoRaSTv4baseHardware]]**. 636 636 637 - =6.FAQ=688 +Feature: Clear flash storage for data log feature. 638 638 690 +(% style="color:blue" %)**AT Command: AT+CLRDTA** 639 639 640 -== 6.1 What is the frequency plan for DDS75-LB? == 692 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:500px" %) 693 +|=(% style="width: 157px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 169px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 174px;background-color:#D9E2F3;color:#0070C0" %)**Response** 694 +|(% style="width:157px" %)AT+CLRDTA|(% style="width:169px" %)Clear flash storage for data log feature.|Clear all stored sensor data… OK 641 641 696 +((( 697 +(% style="color:blue" %)**Downlink Command:** 698 +))) 642 642 643 -DDS75-LB use the same frequency as other Dragino products. User can see the detail from this link: [[Introduction>>doc:Main.End Device Frequency Band.WebHome||anchor="H1.Introduction"]] 700 +((( 701 +* **Example**: 0xA301 ~/~/ Same as AT+CLRDTA 702 +))) 644 644 645 645 646 -== 6.2 Can I use DDS75-LB in condensation environment? == 647 647 706 +=== 3.3.6 Set the calculate flag === 648 648 649 -DDS75-LB is not suitable to be used in condensation environment. Condensation on the DDS75-LB probe will affect the reading and always got 0. 650 650 709 +Feature: Set the calculate flag 651 651 652 - =7. TroubleShooting=711 +(% style="color:blue" %)**AT Command: AT+CALCFLAG** 653 653 654 -== 7.1 Why I can't join TTN V3 in US915 / AU915 bands? == 713 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:461px" %) 714 +|=(% style="width: 158px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 193px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 110px;background-color:#D9E2F3;color:#0070C0" %)**Response** 715 +|(% style="width:158px" %)AT+CALCFLAG =1|(% style="width:192px" %)Set the calculate flag to 1.|(% style="width:109px" %)OK 716 +|(% style="width:158px" %)AT+CALCFLAG =2|(% style="width:192px" %)Set the calculate flag to 2.|(% style="width:109px" %)OK 655 655 718 +(% style="color:blue" %)**Downlink Command:** 656 656 657 - Itis due to channelmapping. Pleaseseebelowlink:[[Frequencyband>>doc:Main.LoRaWAN Communication Debug.WebHome||anchor="H2.NoticeofUS9152FCN4702FAU915Frequencyband"]]720 +* **Example**: 0XA501 ~/~/ Same as AT+CALCFLAG =1 658 658 722 +=== 3.3.7 Set count number === 659 659 660 -== 7.2 AT Command input doesn't work == 661 661 725 +Feature: Manually set the count number 662 662 663 - In the case if user can see the console output but can't type input to the device. Please check if you already include the(% style="color:blue" %)**ENTER**(%%)while sendingout the command. Some serial tool doesn't send (% style="color:blue"%)**ENTER**(%%) while press the send key, user need to add ENTER in their string.727 +(% style="color:blue" %)**AT Command: AT+SETCNT** 664 664 729 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:479px" %) 730 +|=(% style="width: 160px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 223px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 96px;background-color:#D9E2F3;color:#0070C0" %)**Response** 731 +|(% style="width:160px" %)AT+ SETCNT =0|(% style="width:221px" %)Set the count number to 0.|(% style="width:95px" %)OK 732 +|(% style="width:160px" %)AT+ SETCNT =100|(% style="width:221px" %)Set the count number to 100.|(% style="width:95px" %)OK 665 665 666 - ==7.3 Why doeshesensorreadingshow0or "No sensor" ==734 +(% style="color:blue" %)**Downlink Command:** 667 667 736 +* **Example**: 0xA6000001 ~/~/ Same as AT+ SETCNT =1 668 668 669 - ~1.The measurementobjectisveryclosetothesensor,but in the blindspotofthesensor.738 +* **Example**: 0xA6000064 ~/~/ Same as AT+ SETCNT =100 670 670 671 - 2. Sensorwiringis disconnected740 +=== 3.3.8 Set Interrupt Mode === 672 672 673 -3. Not using the correct decoder 674 674 743 +Feature, Set Interrupt mode for PA8 of pin. 675 675 676 - ==7.4AbnormalreadingsThegap betweenmultiplereadingsistoo largeor the gapbetween the readings andtheactualvalueistoolarge ==745 +When AT+INTMOD=0 is set, PA8 is used as a digital input port. 677 677 747 +(% style="color:blue" %)**AT Command: AT+INTMOD** 678 678 679 -1) Please check if there is something on the probe affecting its measurement (condensed water, volatile oil, etc.) 749 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %) 750 +|=(% style="width: 155px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 197px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 158px;background-color:#D9E2F3;color:#0070C0" %)**Response** 751 +|(% style="width:154px" %)AT+INTMOD=?|(% style="width:196px" %)Show current interrupt mode|(% style="width:157px" %)((( 752 +0 753 +OK 754 +the mode is 0 =Disable Interrupt 755 +))) 756 +|(% style="width:154px" %)AT+INTMOD=2|(% style="width:196px" %)((( 757 +Set Transmit Interval 758 +0. (Disable Interrupt), 759 +~1. (Trigger by rising and falling edge) 760 +2. (Trigger by falling edge) 761 +3. (Trigger by rising edge) 762 +)))|(% style="width:157px" %)OK 680 680 681 - 2)Doesitchangewith temperature,temperaturewill affectitsmeasurement764 +(% style="color:blue" %)**Downlink Command: 0x06** 682 682 683 - 3) If abnormal dataoccurs, you canturnon DEBUG mode,Pleaseuse downlinkorATCOMMANtoenter DEBUG mode.766 +Format: Command Code (0x06) followed by 3 bytes. 684 684 685 - downlinkcommand:(%style="color:blue"%)**F101**(%%),AT command:(%style="color:blue"%)**AT+DDEBUG=1**768 +This means that the interrupt mode of the end node is set to 0x000003=3 (rising edge trigger), and the type code is 06. 686 686 687 - 4)After entering the debugmode,itwill send20piecesofdataatatime,andyoucan senditsuplinktous for analysis770 +* Example 1: Downlink Payload: 06000000 ~/~/ Turn off interrupt mode 688 688 689 - [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDDS75%20-%20LoRaWAN%20Distance%20Detection%20Sensor%20User%20Manual/WebHome/image-20230113135125-2.png?width=1057&height=136&rev=1.1||alt="image-20230113135125-2.png"]]772 +* Example 2: Downlink Payload: 06000003 ~/~/ Set the interrupt mode to rising edge trigger 690 690 774 +=== 3.3.9 Set work mode === 691 691 692 -Its original payload will be longer than other data. Even though it is being parsed, it can be seen that it is abnormal data. 693 693 694 - Please sendthedata tous forcheck.777 +Feature: Manually set the work mode 695 695 696 696 697 - =8. OrderInfo=780 +(% style="color:blue" %)**AT Command: AT+MOD** 698 698 782 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:463px" %) 783 +|=(% style="width: 162px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 193px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 108px;background-color:#D9E2F3;color:#0070C0" %)**Response** 784 +|(% style="width:162px" %)AT+MOD=0|(% style="width:191px" %)Set the work mode to 0.|(% style="width:106px" %)OK 785 +|(% style="width:162px" %)AT+MOD=1|(% style="width:191px" %)Set the work mode to 1|(% style="width:106px" %)OK 699 699 700 - Part Number:(% style="color:blue" %)**DDS75-LB-XXX**787 +(% style="color:blue" %)**Downlink Command:** 701 701 702 - (%style="color:red"%)**XXX**(%%):**Thedefaultfrequencyband**789 +* **Example: **0x0A00 ~/~/ Same as AT+MOD=0 703 703 791 +* **Example:** 0x0A01 ~/~/ Same as AT+MOD=1 792 + 793 += 4. Battery & Power Consumption = 794 + 795 + 796 +SW3L-LB use ER26500 + SPC1520 battery pack. See below link for detail information about the battery info and how to replace. 797 + 798 +[[**Battery Info & Power Consumption Analyze**>>http://wiki.dragino.com/xwiki/bin/view/Main/How%20to%20calculate%20the%20battery%20life%20of%20Dragino%20sensors%3F/]] . 799 + 800 + 801 += 5. OTA Firmware update = 802 + 803 + 804 +(% class="wikigeneratedid" %) 805 +User can change firmware SW3L-LB to: 806 + 807 +* Change Frequency band/ region. 808 + 809 +* Update with new features. 810 + 811 +* Fix bugs. 812 + 813 +Firmware and changelog can be downloaded from : **[[Firmware download link>>url:https://www.dropbox.com/sh/kwqv57tp6pejias/AAAopYMATh1GM6fZ-VRCLrpDa?dl=0]]** 814 + 815 +Methods to Update Firmware: 816 + 817 +* (Recommanded way) OTA firmware update via wireless: [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/Firmware%20OTA%20Update%20for%20Sensors/>>url:http://wiki.dragino.com/xwiki/bin/view/Main/Firmware%20OTA%20Update%20for%20Sensors/]] 818 + 819 +* Update through UART TTL interface. **[[Instruction>>url:http://wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H1.LoRaSTv4baseHardware]]**. 820 + 821 += 6. FAQ = 822 + 823 +== 6.1 AT Commands input doesn't work == 824 + 825 + 826 +In the case if user can see the console output but can't type input to the device. Please check if you already include the (% style="color:green" %)**ENTER**(%%) while sending out the command. Some serial tool doesn't send (% style="color:green" %)**ENTER**(%%) while press the send key, user need to add ENTER in their string. 827 + 828 + 829 += 7. Order Info = 830 + 831 + 832 +Part Number: (% style="color:blue" %)**SW3L-LB-XXX-YYY** 833 + 834 +(% style="color:red" %)**XXX**(%%): The default frequency band 835 + 704 704 * (% style="color:red" %)**AS923**(%%): LoRaWAN AS923 band 705 705 706 706 * (% style="color:red" %)**AU915**(%%): LoRaWAN AU915 band ... ... @@ -717,13 +717,43 @@ 717 717 718 718 * (% style="color:red" %)**CN470**(%%): LoRaWAN CN470 band 719 719 852 +((( 853 +(% style="color:blue" %)**YYY**(%%): Flow Sensor Model: 854 +))) 720 720 721 -= 9. Packing Info = 856 +((( 857 + **004:** DW-004 Flow Sensor: diameter: G1/2” / DN15. 450 pulse = 1 L 858 +))) 722 722 860 +((( 861 + **006:** DW-006 Flow Sensor: diameter: G3/4” / DN20. 390 pulse = 1 L 862 +))) 723 723 864 +((( 865 + **010:** DW-010 Flow Sensor: diameter: G 1” / DN25. 64 pulse = 1 L 866 +))) 867 + 868 +* ((( 869 +calculate flag=0: for SW3L-004 Flow Sensor: 450 pulse = 1 L 870 +))) 871 + 872 +* ((( 873 +calculate flag=1: for SW3L-006 Flow Sensor: 390 pulse = 1 L 874 +))) 875 + 876 +* ((( 877 +calculate flag=2: for SW3L-010 Flow Sensor: 64 pulse = 1 L 878 + 879 + 880 + 881 +))) 882 + 883 += 8. Packing Info = 884 + 885 + 724 724 (% style="color:#037691" %)**Package Includes**: 725 725 726 -* DDS75-LB LoRaWANDistance DetectionSensorx 1888 +* SW3L-LB LoRaWAN Flow Sensor 727 727 728 728 (% style="color:#037691" %)**Dimension and weight**: 729 729 ... ... @@ -735,10 +735,9 @@ 735 735 736 736 * Weight / pcs : g 737 737 900 += 9. Support = 738 738 739 -= 10. Support = 740 740 741 - 742 742 * Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule. 743 743 744 744 * Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[Support@dragino.cc>>mailto:Support@dragino.cc]].