... ... @@ -22,13 +22,13 @@
22 22  
23 23  It detects the distance(% style="color:blue" %)**  between the measured object and the sensor**(%%), and uploads the value via wireless to LoRaWAN IoT Server.
24 24  
25 -The LoRa wireless technology used in DDS75-LB allows device to send data and reach extremely long ranges at low data-rates. It provides ultra-long range spread spectrum communication and high interference immunity whilst minimizing current consumption.
25 +The LoRa wireless technology used in SW3L-LB allows device to send data and reach extremely long ranges at low data-rates. It provides ultra-long range spread spectrum communication and high interference immunity whilst minimizing current consumption.
26 26  
27 -DDS75-LB (% style="color:blue" %)**supports BLE configure**(%%) and (% style="color:blue" %)**wireless OTA update**(%%) which make user easy to use.
27 +SW3L-LB (% style="color:blue" %)**supports BLE configure**(%%) and (% style="color:blue" %)**wireless OTA update**(%%) which make user easy to use.
28 28  
29 -DDS75-LB is powered by (% style="color:blue" %)**8500mAh Li-SOCI2 battery**(%%), it is designed for long term use up to 5 years.
29 +SW3L-LB is powered by (% style="color:blue" %)**8500mAh Li-SOCI2 battery**(%%), it is designed for long term use up to 5 years.
30 30  
31 -Each DDS75-LB is pre-load with a set of unique keys for LoRaWAN registrations, register these keys to local LoRaWAN server and it will auto connect after power on.
31 +Each SW3L-LB is pre-load with a set of unique keys for LoRaWAN registrations, register these keys to local LoRaWAN server and it will auto connect after power on.
32 32  
33 33  [[image:image-20230612170943-2.png||height="525" width="912"]]
34 34  
... ... @@ -73,9 +73,9 @@
73 73  )))|(% style="width:66px" %)65%|(% style="width:90px" %)80%|(% style="width:48px" %)RH|(% style="width:203px" %)(1)
74 74  
75 75  (((
76 -(% style="color:red" %)**Remarks: (1) a. When the ambient temperature is 0-39 ℃, the maximum humidity is 90% (non-condensing);       **
76 +**Remarks: (1) a. When the ambient temperature is 0-39 ℃, the maximum humidity is 90% (non-condensing);       **
77 77  
78 -(% style="color:red" %)** b. When the ambient temperature is 40-50 ℃, the highest humidity is the highest humidity in the natural world at the current temperature (no condensation)**
78 +**~ b. When the ambient temperature is 40-50 ℃, the highest humidity is the highest humidity in the natural world at the current temperature (no condensation)**
79 79  
80 80  
81 81  )))
... ... @@ -108,12 +108,12 @@
108 108  == 1.4 Effective measurement range Reference beam pattern ==
109 109  
110 110  
111 -(% style="color:blue" %)**1. The tested object is a white cylindrical tube made of PVC, with a height of 100cm and a diameter of 7.5cm.**
111 +**~1. The tested object is a white cylindrical tube made of PVC, with a height of 100cm and a diameter of 7.5cm.**
112 112  
113 113  [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDDS75%20-%20LoRaWAN%20Distance%20Detection%20Sensor%20User%20Manual/WebHome/1654852253176-749.png?rev=1.1||alt="1654852253176-749.png"]]
114 114  
115 115  
116 -(% style="color:blue" %)**2. The object to be tested is a "corrugated cardboard box" perpendicular to the central axis of 0 °, and the length * width is 60cm * 50cm.**
116 +**2. The object to be tested is a "corrugated cardboard box" perpendicular to the central axis of 0 °, and the length * width is 60cm * 50cm.**
117 117  
118 118  [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDDS75%20-%20LoRaWAN%20Distance%20Detection%20Sensor%20User%20Manual/WebHome/1654852175653-550.png?rev=1.1||alt="1654852175653-550.png"]]
119 119  
... ... @@ -178,8 +178,8 @@
178 178  [[image:image-20230523174230-1.png]]
179 179  
180 180  
181 +== ==
181 181  
182 -
183 183  == 2.10 Mechanical ==
184 184  
185 185  
... ... @@ -192,7 +192,7 @@
192 192  [[image:Main.User Manual for LoRaWAN End Nodes.D20-LBD22-LBD23-LB_LoRaWAN_Temperature_Sensor_User_Manual.WebHome@1675143909447-639.png]]
193 193  
194 194  
195 -(% style="color:blue" %)**Probe Mechanical:**
195 +**Probe Mechanical:**
196 196  
197 197  
198 198  [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDDS75%20-%20LoRaWAN%20Distance%20Detection%20Sensor%20User%20Manual/WebHome/image-20220610172003-1.png?rev=1.1||alt="image-20220610172003-1.png"]]
... ... @@ -268,13 +268,20 @@
268 268  
269 269  
270 270  (((
271 +(((
271 271  DDS75-LB will uplink payload via LoRaWAN with below payload format: 
272 272  )))
273 273  
274 274  (((
275 -Uplink payload includes in total 8 bytes.
276 +Uplink payload includes in total 4 bytes.
277 +Payload for firmware version v1.1.4. . Before v1.1.3, there is on two fields: BAT and Distance
276 276  )))
279 +)))
277 277  
281 +(((
282 +
283 +)))
284 +
278 278  (% border="1" cellspacing="5" style="background-color:#f2f2f2; width:510px" %)
279 279  |=(% style="width: 62.5px;background-color:#D9E2F3;color:#0070C0" %)(((
280 280  **Size(bytes)**
... ... @@ -314,13 +314,12 @@
314 314  
315 315  
316 316  * If the sensor value is 0x0000, it means system doesn't detect ultrasonic sensor.
317 -* If the sensor value lower than 0x0118 (280mm), the sensor value will be invalid. All value lower than 280mm will be set to 0x0014(20mm) which means the value is invalid.
324 +* If the sensor value lower than 0x0118 (280mm), the sensor value will be invalid. Since v1.1.4, all value lower than 280mm will be set to 0x0014(20mm) which means the value is invalid.
318 318  
319 -
320 320  === 2.3.3  Interrupt Pin ===
321 321  
322 322  
323 -This data field shows if this packet is generated by interrupt or not. [[Click here>>||anchor="H3.3.2SetInterruptMode"]] for the hardware and software set up.
329 +This data field shows if this packet is generated by interrupt or not. [[Click here>>||anchor="H3.3A0SetInterruptMode"]] for the hardware and software set up.
324 324  
325 325  **Example:**
326 326  
... ... @@ -340,7 +340,9 @@
340 340  
341 341  If payload is: FF3FH :  (FF3F & FC00 == 1) , temp = (FF3FH - 65536)/10 = -19.3 degrees.
342 342  
349 +(% style="color:red" %)**Note: DS18B20 feature is supported in the hardware version > v1.3 which made since early of 2021.**
343 343  
351 +
344 344  === 2.3.5  Sensor Flag ===
345 345  
346 346  
... ... @@ -370,7 +370,7 @@
370 370  == 2.4  Uplink Interval ==
371 371  
372 372  
373 -The DDS75-LB by default uplink the sensor data every 20 minutes. User can change this interval by AT Command or LoRaWAN Downlink Command. See this link: [[Change Uplink Interval>>||anchor="H3.3.1SetTransmitIntervalTime"]]
381 +The DDS75-LB by default uplink the sensor data every 20 minutes. User can change this interval by AT Command or LoRaWAN Downlink Command. See this link: [[Change Uplink Interval>>doc:Main.End Device AT Commands and Downlink Command.WebHome||anchor="H4.1ChangeUplinkInterval"]]
374 374  
375 375  
376 376  == 2.5  ​Show Data in DataCake IoT Server ==
... ... @@ -415,19 +415,19 @@
415 415  == 2.6 Datalog Feature ==
416 416  
417 417  
418 -Datalog Feature is to ensure IoT Server can get all sampling data from Sensor even if the LoRaWAN network is down. For each sampling, DDS75-LB will store the reading for future retrieving purposes.
426 +Datalog Feature is to ensure IoT Server can get all sampling data from Sensor even if the LoRaWAN network is down. For each sampling, SW3L-LB will store the reading for future retrieving purposes.
419 419  
420 420  
421 421  === 2.6.1 Ways to get datalog via LoRaWAN ===
422 422  
423 423  
424 -Set PNACKMD=1, DDS75-LB will wait for ACK for every uplink, when there is no LoRaWAN network,DDS75-LB will mark these records with non-ack messages and store the sensor data, and it will send all messages (10s interval) after the network recovery.
432 +Set PNACKMD=1, SW3L-LB will wait for ACK for every uplink, when there is no LoRaWAN network,SW3L-LB will mark these records with non-ack messages and store the sensor data, and it will send all messages (10s interval) after the network recovery.
425 425  
426 426  * (((
427 -a) DDS75-LB will do an ACK check for data records sending to make sure every data arrive server.
435 +a) SW3L-LB will do an ACK check for data records sending to make sure every data arrive server.
428 428  )))
429 429  * (((
430 -b) DDS75-LB will send data in **CONFIRMED Mode** when PNACKMD=1, but DDS75-LB won't re-transmit the packet if it doesn't get ACK, it will just mark it as a NONE-ACK message. In a future uplink if DDS75-LB gets a ACK, DDS75-LB will consider there is a network connection and resend all NONE-ACK messages.
438 +b) SW3L-LB will send data in **CONFIRMED Mode** when PNACKMD=1, but SW3L-LB won't re-transmit the packet if it doesn't get ACK, it will just mark it as a NONE-ACK message. In a future uplink if SW3L-LB gets a ACK, SW3L-LB will consider there is a network connection and resend all NONE-ACK messages.
431 431  )))
432 432  
433 433  Below is the typical case for the auto-update datalog feature (Set PNACKMD=1)
... ... @@ -438,7 +438,7 @@
438 438  === 2.6.2 Unix TimeStamp ===
439 439  
440 440  
441 -DDS75-LB uses Unix TimeStamp format based on
449 +SW3L-LB uses Unix TimeStamp format based on
442 442  
443 443  [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/WebHome/image-20220523001219-11.png?width=627&height=97&rev=1.1||alt="图片-20220523001219-11.png" height="97" width="627"]]
444 444  
... ... @@ -457,7 +457,7 @@
457 457  
458 458  User need to set (% style="color:blue" %)**SYNCMOD=1**(%%) to enable sync time via MAC command.
459 459  
460 -Once DDS75-LB Joined LoRaWAN network, it will send the MAC command (DeviceTimeReq) and the server will reply with (DeviceTimeAns) to send the current time to DDS75-LB. If DDS75-LB fails to get the time from the server, DDS75-LB will use the internal time and wait for next time request (AT+SYNCTDC to set the time request period, default is 10 days).
468 +Once SW3L-LB Joined LoRaWAN network, it will send the MAC command (DeviceTimeReq) and the server will reply with (DeviceTimeAns) to send the current time to SW3L-LB. If SW3L-LB fails to get the time from the server, SW3L-LB will use the internal time and wait for next time request (AT+SYNCTDC to set the time request period, default is 10 days).
461 461  
462 462  (% style="color:red" %)**Note: LoRaWAN Server need to support LoRaWAN v1.0.3(MAC v1.0.3) or higher to support this MAC command feature, Chirpstack,TTN V3 v3 and loriot support but TTN V3 v2 doesn't support. If server doesn't support this command, it will through away uplink packet with this command, so user will lose the packet with time request for TTN V3 v2 if SYNCMOD=1.**
463 463  
... ... @@ -485,7 +485,7 @@
485 485  )))
486 486  
487 487  (((
488 -Uplink Internal =5s,means DDS75-LB will send one packet every 5s. range 5~~255s.
496 +Uplink Internal =5s,means SW3L-LB will send one packet every 5s. range 5~~255s.
489 489  )))
490 490  
491 491  
... ... @@ -492,17 +492,17 @@
492 492  == 2.7 Frequency Plans ==
493 493  
494 494  
495 -The DDS75-LB uses OTAA mode and below frequency plans by default. If user want to use it with different frequency plan, please refer the AT command sets.
503 +The SW3L-LB uses OTAA mode and below frequency plans by default. If user want to use it with different frequency plan, please refer the AT command sets.
496 496  
497 497  [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20Frequency%20Band/>>http://wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20Frequency%20Band/]]
498 498  
499 499  
500 -= 3. Configure DDS75-LB =
508 += 3. Configure SW3L-LB =
501 501  
502 502  == 3.1 Configure Methods ==
503 503  
504 504  
505 -DDS75-LB supports below configure method:
513 +SW3L-LB supports below configure method:
506 506  
507 507  * AT Command via Bluetooth Connection (**Recommended**): [[BLE Configure Instruction>>http://wiki.dragino.com/xwiki/bin/view/Main/BLE%20Bluetooth%20Remote%20Configure/]].
508 508  
... ... @@ -524,10 +524,10 @@
524 524  [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/>>http://wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/]]
525 525  
526 526  
527 -== 3.3 Commands special design for DDS75-LB ==
535 +== 3.3 Commands special design for SW3L-LB ==
528 528  
529 529  
530 -These commands only valid for DDS75-LB, as below:
538 +These commands only valid for SW3L-LB, as below:
531 531  
532 532  
533 533  === 3.3.1 Set Transmit Interval Time ===
... ... @@ -572,135 +572,259 @@
572 572  Example 2: Downlink Payload: 0100003C  ~/~/ Set Transmit Interval (TDC) = 60 seconds
573 573  )))
574 574  
575 -=== 3.3.2 Set Interrupt Mode ===
583 +=== 3.3.2 Quit AT Command ===
576 576  
577 577  
578 -Feature, Set Interrupt mode for PA8 of pin.
586 +Feature: Quit AT Command mode, so user needs to input the password again before using AT Commands.
579 579  
580 -When AT+INTMOD=0 is set, PA8 is used as a digital input port.
588 +(% style="color:blue" %)**AT Command: AT+DISAT**
581 581  
582 -(% style="color:blue" %)**AT Command: AT+INTMOD**
590 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:452px" %)
591 +|=(% style="width: 155px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 198px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 99px;background-color:#D9E2F3;color:#0070C0" %)**Response**
592 +|(% style="width:155px" %)AT+DISAT|(% style="width:198px" %)Quit AT Commands mode|(% style="width:96px" %)OK
583 583  
584 -(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %)
585 -|=(% style="width: 155px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 197px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 158px;background-color:#D9E2F3;color:#0070C0" %)**Response**
586 -|(% style="width:154px" %)AT+INTMOD=?|(% style="width:196px" %)Show current interrupt mode|(% style="width:157px" %)(((
587 -0
588 -OK
589 -the mode is 0 =Disable Interrupt
594 +(% style="color:blue" %)**Downlink Command:**
595 +
596 +No downlink command for this feature.
597 +
598 +
599 +=== 3.3.3 Get Device Status ===
600 +
601 +
602 +Send a LoRaWAN downlink to ask device send Alarm settings.
603 +
604 +(% style="color:blue" %)**Downlink Payload:  **(%%)0x26 01
605 +
606 +Sensor will upload Device Status via FPORT=5. See payload section for detail.
607 +
608 +
609 +=== 3.3.4 Alarm for continuously water flow ===
610 +
611 +
612 +(((
613 +This feature is to monitor and send Alarm for continuously water flow.
590 590  )))
591 -|(% style="width:154px" %)AT+INTMOD=2|(% style="width:196px" %)(((
592 -Set Transmit Interval
593 -0. (Disable Interrupt),
594 -~1. (Trigger by rising and falling edge)
595 -2. (Trigger by falling edge)
596 -3. (Trigger by rising edge)
597 -)))|(% style="width:157px" %)OK
598 598  
599 -(% style="color:blue" %)**Downlink Command: 0x06**
616 +(((
617 +Example case is for Toilet water monitoring, if some one push toilet button, the toilet will have water flow. If the toilet button has broken and can't returned to original state, the water flow will keep for hours or days which cause huge waste for water.
618 +)))
600 600  
601 -Format: Command Code (0x06) followed by 3 bytes.
620 +(((
621 +To monitor this faulty and send alarm, there are two settings:
622 +)))
602 602  
603 -This means that the interrupt mode of the end node is set to 0x000003=3 (rising edge trigger), and the type code is 06.
624 +* (((
625 +(% style="color:#4f81bd" %)**Stop Duration: Unit: Second**
626 +)))
604 604  
605 -* Example 1: Downlink Payload: 06000000  ~/~/  Turn off interrupt mode
628 +(((
629 +Default: 15s, If SW3L-LB didn't see any water flow in 15s, SW3L-LB will consider stop of water flow event.
630 +)))
606 606  
607 -* Example 2: Downlink Payload: 06000003  ~/~/  Set the interrupt mode to rising edge trigger
632 +* (((
633 +(% style="color:#4f81bd" %)**Alarm Timer: Units: Minute; Default 0 minutes (means Alarm disable)**
634 +)))
608 608  
609 -= 4. Battery & Power Consumption =
636 +(((
637 +**Example:** 3 minutes, if SW3L-LB detect a start of water flow event and didn't detect a stop event within Alarm timer, SW3L-LB will send an Alarm to indicate a water flow abnormal alarm.
638 +)))
610 610  
640 +(((
641 +So for example, If we set stop duration=15s and Alarm Timer=3minutes. If the toilet water flow continuously for more than 3 minutes, Sensor will send an alarm (in Confirmed MODE) to platform.
642 +)))
611 611  
612 -DDS75-LB use ER26500 + SPC1520 battery pack. See below link for detail information about the battery info and how to replace.
644 +(((
645 +(% style="color:red" %)**Note:** **After this alarm is send, sensor will consider a stop of water flow and count for another new event. So if water flow waste last for 1 hour, Sensor will keep sending alarm every 3 minutes.**
646 +)))
613 613  
614 -[[**Battery Info & Power Consumption Analyze**>>http://wiki.dragino.com/xwiki/bin/view/Main/How%20to%20calculate%20the%20battery%20life%20of%20Dragino%20sensors%3F/]] .
648 +(((
649 +(% style="color:#4f81bd" %)**AT Command**(%%) to configure:
650 +)))
615 615  
652 +* (((
653 +AT+PTRIG=15,3  ~-~-> Set Stop duration: 15s, Alarm Timer: 3 minutes.
654 +)))
616 616  
617 -= 5. OTA Firmware update =
656 +* (((
657 +AT+ PTRIG=15,0  ~-~-> Default Value, disable water waste Alarm.
658 +)))
618 618  
660 +(((
661 +(% style="color:#4f81bd" %)**Downlink Command**(%%) to configure: 
662 +)))
619 619  
620 -(% class="wikigeneratedid" %)
621 -User can change firmware DDS75-LB to:
664 +(((
665 +Command: **0xAA aa bb cc**
666 +)))
622 622  
623 -* Change Frequency band/ region.
668 +(((
669 +AA: Command Type Code
670 +)))
624 624  
625 -* Update with new features.
672 +(((
673 +aa: Stop duration
674 +)))
626 626  
627 -* Fix bugs.
676 +(((
677 +bb cc: Alarm Timer
678 +)))
628 628  
629 -Firmware and changelog can be downloaded from : **[[Firmware download link>>url:https://www.dropbox.com/sh/7la95mae0fn03xe/AACtzs-32m22TLb75B-iIr-Qa?dl=0]]**
680 +(((
681 +If user send 0xAA 0F 00 03: equal to AT+PTRIG=15,3
682 +)))
630 630  
631 -Methods to Update Firmware:
632 632  
633 -* (Recommanded way) OTA firmware update via wireless:  [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/Firmware%20OTA%20Update%20for%20Sensors/>>url:http://wiki.dragino.com/xwiki/bin/view/Main/Firmware%20OTA%20Update%20for%20Sensors/]]
685 +=== 3.3.5 Clear Flash Record ===
634 634  
635 -* Update through UART TTL interface: **[[Instruction>>url:http://wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H1.LoRaSTv4baseHardware]]**.
636 636  
637 -= 6. FAQ =
688 +Feature: Clear flash storage for data log feature.
638 638  
690 +(% style="color:blue" %)**AT Command: AT+CLRDTA**
639 639  
640 -== 6.1  What is the frequency plan for DDS75-LB? ==
692 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:500px" %)
693 +|=(% style="width: 157px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 169px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 174px;background-color:#D9E2F3;color:#0070C0" %)**Response**
694 +|(% style="width:157px" %)AT+CLRDTA|(% style="width:169px" %)Clear flash storage for data log feature.|Clear all stored sensor data… OK
641 641  
696 +(((
697 +(% style="color:blue" %)**Downlink Command:**
698 +)))
642 642  
643 -DDS75-LB use the same frequency as other Dragino products. User can see the detail from this link:  [[Introduction>>doc:Main.End Device Frequency Band.WebHome||anchor="H1.Introduction"]]
700 +(((
701 +* **Example**: 0xA301  ~/~/  Same as AT+CLRDTA
702 +)))
644 644  
645 645  
646 -== 6.2  Can I use DDS75-LB in condensation environment? ==
647 647  
706 +=== 3.3.6 Set the calculate flag ===
648 648  
649 -DDS75-LB is not suitable to be used in condensation environment. Condensation on the DDS75-LB probe will affect the reading and always got 0.
650 650  
709 +Feature: Set the calculate flag
651 651  
652 -= 7.  Trouble Shooting =
711 +(% style="color:blue" %)**AT Command: AT+CALCFLAG**
653 653  
654 -== 7.1  Why I can't join TTN V3 in US915 / AU915 bands? ==
713 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:461px" %)
714 +|=(% style="width: 158px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 193px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 110px;background-color:#D9E2F3;color:#0070C0" %)**Response**
715 +|(% style="width:158px" %)AT+CALCFLAG =1|(% style="width:192px" %)Set the calculate flag to 1.|(% style="width:109px" %)OK
716 +|(% style="width:158px" %)AT+CALCFLAG =2|(% style="width:192px" %)Set the calculate flag to 2.|(% style="width:109px" %)OK
655 655  
718 +(% style="color:blue" %)**Downlink Command:**
656 656  
657 -It is due to channel mapping. Please see below link:  [[Frequency band>>doc:Main.LoRaWAN Communication Debug.WebHome||anchor="H2.NoticeofUS9152FCN4702FAU915Frequencyband"]]
720 +* **Example**: 0XA501  ~/~/  Same as AT+CALCFLAG =1
658 658  
722 +=== 3.3.7 Set count number ===
659 659  
660 -== 7.2  AT Command input doesn't work ==
661 661  
725 +Feature: Manually set the count number
662 662  
663 -In the case if user can see the console output but can't type input to the device. Please check if you already include the (% style="color:blue" %)**ENTER**(%%) while sending out the command. Some serial tool doesn't send (% style="color:blue" %)**ENTER**(%%) while press the send key, user need to add ENTER in their string.
727 +(% style="color:blue" %)**AT Command: AT+SETCNT**
664 664  
729 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:479px" %)
730 +|=(% style="width: 160px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 223px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 96px;background-color:#D9E2F3;color:#0070C0" %)**Response**
731 +|(% style="width:160px" %)AT+ SETCNT =0|(% style="width:221px" %)Set the count number to 0.|(% style="width:95px" %)OK
732 +|(% style="width:160px" %)AT+ SETCNT =100|(% style="width:221px" %)Set the count number to 100.|(% style="width:95px" %)OK
665 665  
666 -== 7.3  Why does the sensor reading show 0 or "No sensor" ==
734 +(% style="color:blue" %)**Downlink Command:**
667 667  
736 +* **Example**: 0xA6000001  ~/~/  Same as AT+ SETCNT =1
668 668  
669 -~1. The measurement object is very close to the sensor, but in the blind spot of the sensor.
738 +* **Example**: 0xA6000064  ~/~/  Same as AT+ SETCNT =100
670 670  
671 -2. Sensor wiring is disconnected
740 +=== 3.3.8 Set Interrupt Mode ===
672 672  
673 -3. Not using the correct decoder
674 674  
743 +Feature, Set Interrupt mode for PA8 of pin.
675 675  
676 -== 7.4  Abnormal readings The gap between multiple readings is too large or the gap between the readings and the actual value is too large ==
745 +When AT+INTMOD=0 is set, PA8 is used as a digital input port.
677 677  
747 +(% style="color:blue" %)**AT Command: AT+INTMOD**
678 678  
679 -1) Please check if there is something on the probe affecting its measurement (condensed water, volatile oil, etc.)
749 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %)
750 +|=(% style="width: 155px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 197px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 158px;background-color:#D9E2F3;color:#0070C0" %)**Response**
751 +|(% style="width:154px" %)AT+INTMOD=?|(% style="width:196px" %)Show current interrupt mode|(% style="width:157px" %)(((
752 +0
753 +OK
754 +the mode is 0 =Disable Interrupt
755 +)))
756 +|(% style="width:154px" %)AT+INTMOD=2|(% style="width:196px" %)(((
757 +Set Transmit Interval
758 +0. (Disable Interrupt),
759 +~1. (Trigger by rising and falling edge)
760 +2. (Trigger by falling edge)
761 +3. (Trigger by rising edge)
762 +)))|(% style="width:157px" %)OK
680 680  
681 -2) Does it change with temperature, temperature will affect its measurement
764 +(% style="color:blue" %)**Downlink Command: 0x06**
682 682  
683 -3) If abnormal data occurs, you can turn on DEBUG mode, Please use downlink or AT COMMAN to enter DEBUG mode.
766 +Format: Command Code (0x06) followed by 3 bytes.
684 684  
685 -downlink command: (% style="color:blue" %)**F1 01**(%%), AT command: (% style="color:blue" %)**AT+DDEBUG=1**
768 +This means that the interrupt mode of the end node is set to 0x000003=3 (rising edge trigger), and the type code is 06.
686 686  
687 -4) After entering the debug mode, it will send 20 pieces of data at a time, and you can send its uplink to us for analysis
770 +* Example 1: Downlink Payload: 06000000  ~/~/  Turn off interrupt mode
688 688  
689 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDDS75%20-%20LoRaWAN%20Distance%20Detection%20Sensor%20User%20Manual/WebHome/image-20230113135125-2.png?width=1057&height=136&rev=1.1||alt="image-20230113135125-2.png"]]
772 +* Example 2: Downlink Payload06000003  ~/~/  Set the interrupt mode to rising edge trigger
690 690  
774 +=== 3.3.9 Set work mode ===
691 691  
692 -Its original payload will be longer than other data. Even though it is being parsed, it can be seen that it is abnormal data.
693 693  
694 -Please send the data to us for check.
777 +Feature: Manually set the work mode
695 695  
696 696  
697 -= 8. Order Info =
780 +(% style="color:blue" %)**AT Command: AT+MOD**
698 698  
782 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:463px" %)
783 +|=(% style="width: 162px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 193px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 108px;background-color:#D9E2F3;color:#0070C0" %)**Response**
784 +|(% style="width:162px" %)AT+MOD=0|(% style="width:191px" %)Set the work mode to 0.|(% style="width:106px" %)OK
785 +|(% style="width:162px" %)AT+MOD=1|(% style="width:191px" %)Set the work mode to 1|(% style="width:106px" %)OK
699 699  
700 -Part Number: (% style="color:blue" %)**DDS75-LB-XXX**
787 +(% style="color:blue" %)**Downlink Command:**
701 701  
702 -(% style="color:red" %)**XXX**(%%): **The default frequency band**
789 +* **Example: **0x0A00  ~/~/  Same as AT+MOD=0
703 703  
791 +* **Example:** 0x0A01  ~/~/  Same as AT+MOD=1
792 +
793 += 4. Battery & Power Consumption =
794 +
795 +
796 +SW3L-LB use ER26500 + SPC1520 battery pack. See below link for detail information about the battery info and how to replace.
797 +
798 +[[**Battery Info & Power Consumption Analyze**>>http://wiki.dragino.com/xwiki/bin/view/Main/How%20to%20calculate%20the%20battery%20life%20of%20Dragino%20sensors%3F/]] .
799 +
800 +
801 += 5. OTA Firmware update =
802 +
803 +
804 +(% class="wikigeneratedid" %)
805 +User can change firmware SW3L-LB to:
806 +
807 +* Change Frequency band/ region.
808 +
809 +* Update with new features.
810 +
811 +* Fix bugs.
812 +
813 +Firmware and changelog can be downloaded from : **[[Firmware download link>>url:https://www.dropbox.com/sh/kwqv57tp6pejias/AAAopYMATh1GM6fZ-VRCLrpDa?dl=0]]**
814 +
815 +Methods to Update Firmware:
816 +
817 +* (Recommanded way) OTA firmware update via wireless:   [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/Firmware%20OTA%20Update%20for%20Sensors/>>url:http://wiki.dragino.com/xwiki/bin/view/Main/Firmware%20OTA%20Update%20for%20Sensors/]]
818 +
819 +* Update through UART TTL interface. **[[Instruction>>url:http://wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H1.LoRaSTv4baseHardware]]**.
820 +
821 += 6. FAQ =
822 +
823 +== 6.1  AT Commands input doesn't work ==
824 +
825 +
826 +In the case if user can see the console output but can't type input to the device. Please check if you already include the (% style="color:green" %)**ENTER**(%%) while sending out the command. Some serial tool doesn't send (% style="color:green" %)**ENTER**(%%) while press the send key, user need to add ENTER in their string.
827 +
828 +
829 += 7. Order Info =
830 +
831 +
832 +Part Number: (% style="color:blue" %)**SW3L-LB-XXX-YYY**
833 +
834 +(% style="color:red" %)**XXX**(%%): The default frequency band
835 +
704 704  * (% style="color:red" %)**AS923**(%%): LoRaWAN AS923 band
705 705  
706 706  * (% style="color:red" %)**AU915**(%%): LoRaWAN AU915 band
... ... @@ -717,13 +717,43 @@
717 717  
718 718  * (% style="color:red" %)**CN470**(%%): LoRaWAN CN470 band
719 719  
852 +(((
853 +(% style="color:blue" %)**YYY**(%%): Flow Sensor Model:
854 +)))
720 720  
721 -= 9. ​Packing Info =
856 +(((
857 + **004:** DW-004 Flow Sensor: diameter: G1/2” / DN15.  450 pulse = 1 L
858 +)))
722 722  
860 +(((
861 + **006:** DW-006 Flow Sensor: diameter: G3/4” / DN20. 390 pulse = 1 L
862 +)))
723 723  
864 +(((
865 + **010:** DW-010 Flow Sensor: diameter: G 1” / DN25. 64 pulse = 1 L
866 +)))
867 +
868 +* (((
869 +calculate flag=0: for SW3L-004 Flow Sensor: 450 pulse = 1 L
870 +)))
871 +
872 +* (((
873 +calculate flag=1: for SW3L-006 Flow Sensor: 390 pulse = 1 L
874 +)))
875 +
876 +* (((
877 +calculate flag=2: for SW3L-010 Flow Sensor: 64  pulse = 1 L
878 +
879 +
880 +
881 +)))
882 +
883 += 8. ​Packing Info =
884 +
885 +
724 724  (% style="color:#037691" %)**Package Includes**:
725 725  
726 -* DDS75-LB LoRaWAN Distance Detection Sensor x 1
888 +* SW3L-LB LoRaWAN Flow Sensor
727 727  
728 728  (% style="color:#037691" %)**Dimension and weight**:
729 729  
... ... @@ -735,10 +735,9 @@
735 735  
736 736  * Weight / pcs : g
737 737  
900 += 9. Support =
738 738  
739 -= 10. Support =
740 740  
741 -
742 742  * Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule.
743 743  
744 744  * Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[Support@dragino.cc>>mailto:Support@dragino.cc]].