Changes for page DS20L -- LoRaWAN Smart Distance Detector User Manual 01
Last modified by Mengting Qiu on 2023/12/14 11:15
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -22,13 +22,13 @@ 22 22 23 23 It detects the distance(% style="color:blue" %)** between the measured object and the sensor**(%%), and uploads the value via wireless to LoRaWAN IoT Server. 24 24 25 -The LoRa wireless technology used in DDS75-LB allows device to send data and reach extremely long ranges at low data-rates. It provides ultra-long range spread spectrum communication and high interference immunity whilst minimizing current consumption.25 +The LoRa wireless technology used in SW3L-LB allows device to send data and reach extremely long ranges at low data-rates. It provides ultra-long range spread spectrum communication and high interference immunity whilst minimizing current consumption. 26 26 27 - DDS75-LB (% style="color:blue" %)**supports BLE configure**(%%) and (% style="color:blue" %)**wireless OTA update**(%%) which make user easy to use.27 +SW3L-LB (% style="color:blue" %)**supports BLE configure**(%%) and (% style="color:blue" %)**wireless OTA update**(%%) which make user easy to use. 28 28 29 - DDS75-LB is powered by (% style="color:blue" %)**8500mAh Li-SOCI2 battery**(%%), it is designed for long term use up to 5 years.29 +SW3L-LB is powered by (% style="color:blue" %)**8500mAh Li-SOCI2 battery**(%%), it is designed for long term use up to 5 years. 30 30 31 -Each DDS75-LB is pre-load with a set of unique keys for LoRaWAN registrations, register these keys to local LoRaWAN server and it will auto connect after power on.31 +Each SW3L-LB is pre-load with a set of unique keys for LoRaWAN registrations, register these keys to local LoRaWAN server and it will auto connect after power on. 32 32 33 33 [[image:image-20230612170943-2.png||height="525" width="912"]] 34 34 ... ... @@ -39,47 +39,20 @@ 39 39 * LoRaWAN 1.0.3 Class A 40 40 * Bands: CN470/EU433/KR920/US915/EU868/AS923/AU915/IN865 41 41 * Ultra-low power consumption 42 -* DistanceDetectionby Ultrasonictechnology43 -* Flatobjectnge280mm - 7500mm44 -* A ccuracy:±(1cm+S*0.3%) (S: Distance)45 -* CableLength : 25cm42 +* Upload water flow volume 43 +* Monitor water waste 44 +* AT Commands to change parameters 45 +* supports Datalog feature 46 46 * Support Bluetooth v5.1 and LoRaWAN remote configure 47 47 * Support wireless OTA update firmware 48 -* ATCommandstohangeparameters48 +* Uplink on periodically and open/close event 49 49 * Downlink to change configure 50 -* IP66 Waterproof Enclosure 51 51 * 8500mAh Battery for long term use 52 52 52 + 53 53 == 1.3 Specification == 54 54 55 55 56 -(% style="color:#037691" %)**Rated environmental conditions:** 57 - 58 -(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:500px" %) 59 -|(% style="background-color:#d9e2f3; color:#0070c0; width:163px" %)**Item**|(% style="background-color:#d9e2f3; color:#0070c0; width:90px" %)((( 60 -**Minimum value** 61 -)))|(% style="background-color:#d9e2f3; color:#0070c0; width:70px" %)((( 62 -**Typical value** 63 -)))|(% style="background-color:#d9e2f3; color:#0070c0; width:87px" %)((( 64 -**Maximum value** 65 -)))|(% style="background-color:#d9e2f3; color:#0070c0; width:40px" %)**Unit**|(% style="background-color:#d9e2f3; color:#0070c0; width:50px" %)**Remarks** 66 -|(% style="width:174px" %)Storage temperature|(% style="width:86px" %)-25|(% style="width:66px" %)25|(% style="width:90px" %)80|(% style="width:48px" %)℃|(% style="width:203px" %) 67 -|(% style="width:174px" %)Storage humidity|(% style="width:86px" %) |(% style="width:66px" %)65%|(% style="width:90px" %)90%|(% style="width:48px" %)RH|(% style="width:203px" %)(1) 68 -|(% style="width:174px" %)Operating temperature|(% style="width:86px" %)-15|(% style="width:66px" %)25|(% style="width:90px" %)60|(% style="width:48px" %)℃|(% style="width:203px" %) 69 -|(% style="width:174px" %)Working humidity|(% style="width:86px" %)((( 70 - 71 - 72 - 73 -)))|(% style="width:66px" %)65%|(% style="width:90px" %)80%|(% style="width:48px" %)RH|(% style="width:203px" %)(1) 74 - 75 -((( 76 -(% style="color:red" %)**Remarks: (1) a. When the ambient temperature is 0-39 ℃, the maximum humidity is 90% (non-condensing); ** 77 - 78 -(% style="color:red" %)** b. When the ambient temperature is 40-50 ℃, the highest humidity is the highest humidity in the natural world at the current temperature (no condensation)** 79 - 80 - 81 -))) 82 - 83 83 (% style="color:#037691" %)**Common DC Characteristics:** 84 84 85 85 * Supply Voltage: built in 8500mAh Li-SOCI2 battery , 2.5v ~~ 3.6v ... ... @@ -105,41 +105,25 @@ 105 105 * Sleep Mode: 5uA @ 3.3v 106 106 * LoRa Transmit Mode: 125mA @ 20dBm, 82mA @ 14dBm 107 107 108 -== 1.4 Effective measurement range Reference beam pattern == 109 109 82 +== 1.4 Applications == 110 110 111 -(% style="color:blue" %)**1. The tested object is a white cylindrical tube made of PVC, with a height of 100cm and a diameter of 7.5cm.** 112 112 113 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDDS75%20-%20LoRaWAN%20Distance%20Detection%20Sensor%20User%20Manual/WebHome/1654852253176-749.png?rev=1.1||alt="1654852253176-749.png"]] 85 +* Flow Sensor application 86 +* Water Control 87 +* Toilet Flow Sensor 88 +* Monitor Waste water 114 114 115 115 116 - (% style="color:blue"%)**2.Theobjecttobe testedis a "corrugatedcardboardbox" perpendicular to the centralaxisof 0 °, andthelength * width is 60cm * 50cm.**91 +== 1.5 Sleep mode and working mode == 117 117 118 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDDS75%20-%20LoRaWAN%20Distance%20Detection%20Sensor%20User%20Manual/WebHome/1654852175653-550.png?rev=1.1||alt="1654852175653-550.png"]] 119 119 120 - 121 -== 1.5 Applications == 122 - 123 - 124 -* Horizontal distance measurement 125 -* Liquid level measurement 126 -* Parking management system 127 -* Object proximity and presence detection 128 -* Intelligent trash can management system 129 -* Robot obstacle avoidance 130 -* Automatic control 131 -* Sewer 132 -* Bottom water level monitoring 133 - 134 -== 1.6 Sleep mode and working mode == 135 - 136 - 137 137 (% style="color:blue" %)**Deep Sleep Mode: **(%%)Sensor doesn't have any LoRaWAN activate. This mode is used for storage and shipping to save battery life. 138 138 139 139 (% style="color:blue" %)**Working Mode:** (%%)In this mode, Sensor will work as LoRaWAN Sensor to Join LoRaWAN network and send out sensor data to server. Between each sampling/tx/rx periodically, sensor will be in IDLE mode), in IDLE mode, sensor has the same power consumption as Deep Sleep mode. 140 140 141 141 142 -== 1. 7Button & LEDs ==99 +== 1.6 Button & LEDs == 143 143 144 144 145 145 [[image:Main.User Manual for LoRaWAN End Nodes.D20-LBD22-LBD23-LB_LoRaWAN_Temperature_Sensor_User_Manual.WebHome@1675071855856-879.png]] ... ... @@ -158,12 +158,13 @@ 158 158 ))) 159 159 |(% style="width:167px" %)Fast press ACT 5 times.|(% style="width:117px" %)Deactivate Device|(% style="width:225px" %)(% style="color:red" %)**Red led**(%%) will solid on for 5 seconds. Means device is in Deep Sleep Mode. 160 160 161 -== 1.8 BLE connection == 162 162 119 +== 1.7 BLE connection == 163 163 164 -DDS75-LB support BLE remote configure. 165 165 122 +SW3L-LB support BLE remote configure. 166 166 124 + 167 167 BLE can be used to configure the parameter of sensor or see the console output from sensor. BLE will be only activate on below case: 168 168 169 169 * Press button to send an uplink ... ... @@ -173,13 +173,24 @@ 173 173 If there is no activity connection on BLE in 60 seconds, sensor will shut down BLE module to enter low power mode. 174 174 175 175 176 -== 1. 9Pin Definitions ==134 +== 1.8 Pin Definitions == 177 177 178 178 [[image:image-20230523174230-1.png]] 179 179 180 180 139 +== 1.9 Flow Sensor Spec == 181 181 182 182 142 +((( 143 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:510px" %) 144 +|=(% style="width: 80px;background-color:#D9E2F3;color:#0070C0" %)**Model**|=(% style="width: 80px;background-color:#D9E2F3;color:#0070C0" %)**Probe**|=(% style="width: 80px;background-color:#D9E2F3;color:#0070C0" %)**Diameter**|=(% style="width: 80px;background-color:#D9E2F3;color:#0070C0" %)**Range**|=(% style="width: 80px;background-color:#D9E2F3;color:#0070C0" %)**Max Pressure**|=(% style="width: 110px;background-color:#D9E2F3;color:#0070C0" %)**Measure** 145 +|(% style="width:88px" %)SW3L-004|(% style="width:75px" %)DW-004|(% style="width:107px" %)G1/2" /DN15|(% style="width:101px" %)1~~30L/min|(% style="width:116px" %)≤ 2.0Mpa|(% style="width:124px" %)450 pulse = 1 L 146 +|(% style="width:88px" %)SW3L-006|(% style="width:75px" %)DW-006|(% style="width:107px" %)G3/4" /DN20|(% style="width:101px" %)1~~60L/min|(% style="width:116px" %)≤ 1.2Mpa|(% style="width:124px" %)390 pulse = 1 L 147 +|(% style="width:88px" %)SW3L-010|(% style="width:75px" %)DW-010|(% style="width:107px" %)G 1" /DN25|(% style="width:101px" %)2~~100L/min|(% style="width:116px" %)≤ 2.0Mpa|(% style="width:124px" %)64 pulse = 1 L 148 +))) 149 + 150 + 151 + 183 183 == 2.10 Mechanical == 184 184 185 185 ... ... @@ -192,24 +192,27 @@ 192 192 [[image:Main.User Manual for LoRaWAN End Nodes.D20-LBD22-LBD23-LB_LoRaWAN_Temperature_Sensor_User_Manual.WebHome@1675143909447-639.png]] 193 193 194 194 195 -(% style="color:blue" %)** ProbeMechanical:**164 +(% style="color:blue" %)**DW-004 Flow Sensor: diameter: G1/2” / DN15. 450 pulse = 1 L** 196 196 166 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/SW3L%20LoRaWAN%20Outdoor%20Flow%20Sensor/WebHome/image-20220519091350-1.png?width=722&height=385&rev=1.1||alt="image-20220519091350-1.png"]] 197 197 198 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDDS75%20-%20LoRaWAN%20Distance%20Detection%20Sensor%20User%20Manual/WebHome/image-20220610172003-1.png?rev=1.1||alt="image-20220610172003-1.png"]] 199 199 169 +(% style="color:blue" %)**006: DW-006 Flow Sensor: diameter: G3/4” / DN20. 390 pulse = 1 L** 200 200 201 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/ LDDS75%20-%20LoRaWAN%20Distance%20Detection%20Sensor%20User%20Manual/WebHome/image-20220610172003-2.png?rev=1.1||alt="image-20220610172003-2.png"]]171 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/SW3L%20LoRaWAN%20Outdoor%20Flow%20Sensor/WebHome/image-20220519091423-2.png?width=723&height=258&rev=1.1||alt="image-20220519091423-2.png"]] 202 202 203 203 204 - [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDDS75%20-%20LoRaWAN%20Distance%20Detection%20Sensor%20User%20Manual/WebHome/image-20220610172003-2.png?rev=1.1||alt="image-20220610172003-2.png"]]174 +(% style="color:blue" %)**010: DW-010 Flow Sensor: diameter: G 1” / DN25. 64 pulse = 1 L** 205 205 176 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/SW3L%20LoRaWAN%20Outdoor%20Flow%20Sensor/WebHome/image-20220519091423-3.png?width=724&height=448&rev=1.1||alt="image-20220519091423-3.png"]] 206 206 207 -= 2. Configure DDS75-LB to connect to LoRaWAN network = 208 208 179 += 2. Configure SW3L-LB to connect to LoRaWAN network = 180 + 209 209 == 2.1 How it works == 210 210 211 211 212 -The DDS75-LB is configured as (% style="color:#037691" %)**LoRaWAN OTAA Class A**(%%) mode by default. It has OTAA keys to join LoRaWAN network. To connect a local LoRaWAN network, you need to input the OTAA keys in the LoRaWAN IoT server and press the button to activate theDDS75-LB. It will automatically join the network via OTAA and start to send the sensor value. The default uplink interval is 20 minutes.184 +The SW3L-LB is configured as (% style="color:#037691" %)**LoRaWAN OTAA Class A**(%%) mode by default. It has OTAA keys to join LoRaWAN network. To connect a local LoRaWAN network, you need to input the OTAA keys in the LoRaWAN IoT server and press the button to activate the SW3L-LB. It will automatically join the network via OTAA and start to send the sensor value. The default uplink interval is 20 minutes. 213 213 214 214 (% style="display:none" %) (%%) 215 215 ... ... @@ -223,9 +223,9 @@ 223 223 [[image:image-20230612171032-3.png||height="492" width="855"]](% style="display:none" %) 224 224 225 225 226 -(% style="color:blue" %)**Step 1:**(%%) Create a device in TTN with the OTAA keys from DDS75-LB.198 +(% style="color:blue" %)**Step 1:**(%%) Create a device in TTN with the OTAA keys from SW3L-LB. 227 227 228 -Each DDS75-LB is shipped with a sticker with the default device EUI as below:200 +Each SW3L-LB is shipped with a sticker with the default device EUI as below: 229 229 230 230 [[image:image-20230426084152-1.png||alt="图片-20230426084152-1.png" height="233" width="502"]] 231 231 ... ... @@ -254,10 +254,10 @@ 254 254 [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LSN50v2-S31-S31B%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20User%20Manual/WebHome/image-20220611161308-6.png?width=744&height=485&rev=1.1||alt="图片-20220611161308-6.png"]] 255 255 256 256 257 -(% style="color:blue" %)**Step 2:**(%%) Activate on DDS75-LB229 +(% style="color:blue" %)**Step 2:**(%%) Activate on SW3L-LB 258 258 259 259 260 -Press the button for 5 seconds to activate the DDS75-LB.232 +Press the button for 5 seconds to activate the SW3L-LB. 261 261 262 262 (% style="color:green" %)**Green led**(%%) will fast blink 5 times, device will enter (% style="color:blue" %)**OTA mode**(%%) for 3 seconds. And then start to JOIN LoRaWAN network. (% style="color:green" %)**Green led**(%%) will solidly turn on for 5 seconds after joined in network. 263 263 ... ... @@ -264,172 +264,355 @@ 264 264 After join success, it will start to upload messages to TTN and you can see the messages in the panel. 265 265 266 266 267 -== 2.3 239 +== 2.3 Uplink Payload == 268 268 241 +=== 2.3.1 Device Status, FPORT~=5 === 269 269 270 -((( 271 -DDS75-LB will uplink payload via LoRaWAN with below payload format: 272 -))) 273 273 274 -((( 275 -Uplink payload includes in total 8 bytes. 276 -))) 244 +Include device configure status. Once SW3L-LB Joined the network, it will uplink this message to the server. After that, SW3L-LB will uplink Device Status every 12 hours. 277 277 278 -(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:510px" %) 279 -|=(% style="width: 62.5px;background-color:#D9E2F3;color:#0070C0" %)((( 280 -**Size(bytes)** 281 -)))|=(% style="width: 62.5px;background-color:#D9E2F3;color:#0070C0" %)**2**|=(% style="background-color:#D9E2F3;color:#0070C0" %)**2**|=(% style="background-color:#D9E2F3;color:#0070C0" %)1|=(% style="background-color:#D9E2F3;color:#0070C0" %)2|=(% style="background-color:#D9E2F3;color:#0070C0" %)**1** 282 -|(% style="width:62.5px" %)**Value**|(% style="width:62.5px" %)[[BAT>>||anchor="H2.3.1A0BatteryInfo"]]|((( 283 -[[Distance>>||anchor="H2.3.2A0Distance"]] 284 -(unit: mm) 285 -)))|[[Digital Interrupt (Optional)>>||anchor="H2.3.3A0InterruptPin"]]|((( 286 -[[Temperature (Optional )>>||anchor="H2.3.4A0DS18B20Temperaturesensor"]] 287 -)))|[[Sensor Flag>>||anchor="H2.3.5A0SensorFlag"]] 246 +Users can use the downlink command(**0x26 01**) to ask SW3L-LB to send device configure detail, include device configure status. SW3L-LB will uplink a payload via FPort=5 to server. 288 288 289 - [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDDS75%20-%20LoRaWAN%20Distance%20Detection%20Sensor%20User%20Manual/WebHome/1654850511545-399.png?rev=1.1||alt="1654850511545-399.png"]]248 +The Payload format is as below. 290 290 291 291 292 -=== 2.3.1 Battery Info === 251 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %) 252 +|(% colspan="6" style="background-color:#d9e2f3; color:#0070c0" %)**Device Status (FPORT=5)** 253 +|(% style="width:103px" %)**Size (bytes)**|(% style="width:72px" %)**1**|**2**|(% style="width:91px" %)**1**|(% style="width:86px" %)**1**|(% style="width:44px" %)**2** 254 +|(% style="width:103px" %)**Value**|(% style="width:72px" %)Sensor Model|Firmware Version|(% style="width:91px" %)Frequency Band|(% style="width:86px" %)Sub-band|(% style="width:44px" %)BAT 293 293 256 +Example parse in TTNv3 294 294 295 - Check the battery voltageDDS75-LB.258 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/SW3L%20LoRaWAN%20Outdoor%20Flow%20Sensor/WebHome/1652925144491-755.png?width=732&height=139&rev=1.1||alt="1652925144491-755.png"]] 296 296 260 + 261 +(% style="color:#037691" %)**Sensor Model**(%%): For SW3L-LB, this value is 0x11 262 + 263 +(% style="color:#037691" %)**Firmware Version**(%%): 0x0100, Means: v1.0.0 version 264 + 265 +(% style="color:#037691" %)**Frequency Band**: 266 + 267 +*0x01: EU868 268 + 269 +*0x02: US915 270 + 271 +*0x03: IN865 272 + 273 +*0x04: AU915 274 + 275 +*0x05: KZ865 276 + 277 +*0x06: RU864 278 + 279 +*0x07: AS923 280 + 281 +*0x08: AS923-1 282 + 283 +*0x09: AS923-2 284 + 285 +*0x0a: AS923-3 286 + 287 +*0x0b: CN470 288 + 289 +*0x0c: EU433 290 + 291 +*0x0d: KR920 292 + 293 +*0x0e: MA869 294 + 295 + 296 +(% style="color:#037691" %)**Sub-Band**: 297 + 298 +AU915 and US915:value 0x00 ~~ 0x08 299 + 300 +CN470: value 0x0B ~~ 0x0C 301 + 302 +Other Bands: Always 0x00 303 + 304 + 305 +(% style="color:#037691" %)**Battery Info**: 306 + 307 +Check the battery voltage. 308 + 297 297 Ex1: 0x0B45 = 2885mV 298 298 299 299 Ex2: 0x0B49 = 2889mV 300 300 301 301 302 -=== 2.3.2 Distance===314 +=== 2.3.2 Sensor Configuration, FPORT~=4 === 303 303 304 304 317 +SW3L-LB will only send this command after getting the downlink command (0x26 02) from the server. 318 + 319 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:510px" %) 320 +|(% style="background-color:#d9e2f3; color:#0070c0; width:70px" %) **Size(bytes)**|(% style="background-color:#d9e2f3; color:#0070c0; width:105px" %)**3**|(% style="background-color:#d9e2f3; color:#0070c0; width:60px" %)**1**|(% style="background-color:#d9e2f3; color:#0070c0; width:96px" %)**1**|(% style="background-color:#d9e2f3; color:#0070c0; width:105px" %)**2**|(% style="background-color:#d9e2f3; color:#0070c0; width:74px" %)**1** 321 +|**Value**|(% style="width:104px" %)TDC(unit:sec)|(% style="width:43px" %)N/A|(% style="width:91px" %)Stop Timer|(% style="width:100px" %)Alarm Timer|(% style="width:69px" %)Reserve 322 + 323 +* (% style="color:#037691" %)**TDC: (default: 0x0004B0)** 324 + 325 +Uplink interval for the total pulse count, default value is 0x0004B0 which is 1200 seconds = 20 minutes. 326 + 327 + 328 +* (% style="color:#037691" %)**STOP Duration & Alarm Timer** 329 + 330 +Shows the configure value of [[Alarm for continuously water flow>>||anchor="H3.3.4Alarmforcontinuouslywaterflow"]] 331 + 332 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/SW3L%20LoRaWAN%20Outdoor%20Flow%20Sensor/WebHome/image-20220519095747-2.png?width=723&height=113&rev=1.1||alt="image-20220519095747-2.png"]] 333 + 334 + 335 +=== 2.3.3 Water Flow Value, Uplink FPORT~=2 === 336 + 337 + 305 305 ((( 306 - Getthe distance.Flat objectrange280mm-7500mm.339 +SW3L-LB will send this uplink **after** Device Status once join the LoRaWAN network successfully. And SW3L-LB will: 307 307 ))) 308 308 309 309 ((( 310 -For example, if the data you get from the register is 0x0B 0x05, the distance between the sensor and the measured object is(% style="color:#4472c4" %)** ** 343 +periodically send this uplink every 20 minutes, this interval [[can be changed>>||anchor="H3.3.1SetTransmitIntervalTime"]]. 344 +))) 311 311 312 -(% style="color:#4472c4" %)**0B05(H) = 2821 (D) = 2821 mm.** 346 +((( 347 +Uplink Payload totals 11 bytes. 313 313 ))) 314 314 350 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:510px" %) 351 +|=(% colspan="6" style="width: 510px;background-color:#D9E2F3;color:#0070C0" %)**Water Flow Value, FPORT=2** 352 +|(% style="width:60px" %)**Size(bytes)**|(% style="width:130px" %)**1**|(% style="width:130px" %)**4**|(% style="width:30px" %)**1**|(% style="width:50px" %)**1**|(% style="width:80px" %)**4** 353 +|(% style="width:110px" %)**Value**|(% style="width:81px" %)Calculate Flag & [[Alarm>>||anchor="H3.3.4Alarmforcontinuouslywaterflow"]]|(% style="width:95px" %)((( 354 +Total pulse Or Last Pulse 355 +)))|(% style="width:55px" %)MOD|(% style="width:115px" %)Reserve(0x01)|(% style="width:129px" %)[[Unix TimeStamp>>||anchor="H2.5.2UnixTimeStamp"]] 315 315 316 -* If the sensor value is 0x0000, it means system doesn't detect ultrasonic sensor. 317 -* If the sensor value lower than 0x0118 (280mm), the sensor value will be invalid. Since v1.1.4, all value lower than 280mm will be set to 0x0014(20mm) which means the value is invalid. 357 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:470px" %) 358 +|=(% colspan="4" style="width: 470px;background-color:#D9E2F3;color:#0070C0" %)**Status & Alarm field** 359 +|(% style="width:60px" %)**Size(bit)**|(% style="width:80px" %)**6**|(% style="width:310px" %)**1**|(% style="width:20px" %)**1** 360 +|(% style="width:88px" %)**Value**|(% style="width:117px" %)Calculate Flag|(% style="width:221px" %)Alarm: 0: No Alarm; 1: Alarm|(% style="width:64px" %)N/A 318 318 362 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/SW3L%20LoRaWAN%20Outdoor%20Flow%20Sensor/WebHome/image-20220519095946-3.png?width=736&height=284&rev=1.1||alt="image-20220519095946-3.png"]] 319 319 320 -=== 2.3.3 Interrupt Pin === 321 321 365 +* ((( 366 +(% style="color:#037691" %)**Calculate Flag** 367 +))) 322 322 323 -This data field shows if this packet is generated by interrupt or not. [[Click here>>||anchor="H3.3A0SetInterruptMode"]] for the hardware and software set up. 369 +((( 370 +The calculate flag is a user defined field, IoT server can use this flag to handle different meters with different pulse factors. For example, if there are 100 Flow Sensors, meters 1 ~~50 are 1 liter/pulse and meters 51 ~~ 100 has 1.5 liter/pulse. 371 +))) 324 324 325 -**Example:** 373 +((( 374 +**Example: in the default payload:** 375 +))) 326 326 327 -0x00: Normal uplink packet. 377 +* ((( 378 +calculate flag=0: for SW3L-004 Flow Sensor: 450 pulse = 1 L 379 +))) 380 +* ((( 381 +calculate flag=1: for SW3L-006 Flow Sensor: 390 pulse = 1 L 382 +))) 383 +* ((( 384 +calculate flag=2: for SW3L-010 Flow Sensor: 64 pulse = 1 L 385 +))) 328 328 329 -0x01: Interrupt Uplink Packet. 387 +((( 388 +Default value: 0. 389 +))) 330 330 391 +((( 392 +Range (6 bits): (b)000000 ~~ (b) 111111 331 331 332 - ===2.3.4DS18B20Temperaturesensor===394 +If user use with a meter for example is 0.02L/pulse. To proper decode the correct value in server, 333 333 396 +1) User can set the Calculate Flag of this sensor to 3. 334 334 335 -This is optional, user can connect external DS18B20 sensor to the +3.3v, 1-wire and GND pin . and this field will report temperature. 398 +2) In server side, when a sensor data arrive, the decoder will check the value of Calculate Flag, It the value is 3, the total volume = 0.02 x Pulse Count. 399 +))) 336 336 337 -**Example**: 401 +((( 402 +(% style="color:red" %)**NOTE: User need to set Calculate Flag to proper value before use Flow Sensor. Downlink or AT Command see: **(%%)Refer: [[Set Calculate Flag>>||anchor="H3.3.6Setthecalculateflag"]] 403 +))) 338 338 339 -If payload is: 0105H: (0105 & FC00 == 0), temp = 0105H /10 = 26.1 degree 405 +* ((( 406 +(% style="color:#037691" %)**Alarm** 407 +))) 340 340 341 -If payload is: FF3FH : (FF3F & FC00 == 1) , temp = (FF3FH - 65536)/10 = -19.3 degrees. 409 +((( 410 +See [[Alarm for continuously water flow>>||anchor="H3.3.4Alarmforcontinuouslywaterflow"]] 411 +))) 342 342 343 - (% style="color:red"%)**Note: DS18B20featureissupportedinardwareersion > v1.3 whichmadesince early of2021.**413 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/SW3L%20LoRaWAN%20Outdoor%20Flow%20Sensor/WebHome/image-20220519095946-4.png?width=724&height=65&rev=1.1||alt="image-20220519095946-4.png"]] 344 344 345 345 346 -=== 2.3.5 Sensor Flag === 416 +* ((( 417 +(% style="color:#037691" %)**Total pulse** 418 +))) 347 347 420 +((( 421 +Total pulse/counting since factory 422 +))) 348 348 349 349 ((( 350 - 0x01: Detect UltrasonicSensor425 +Range (4 Bytes) : 0x00000000~~ 0xFFFFFFFF . 351 351 ))) 352 352 428 +* ((( 429 +(% style="color:#037691" %)**Last Pulse** 430 +))) 431 + 353 353 ((( 354 - 0x00: NoUltrasonicSensor433 +Total pulse since last FPORT=2 uplink. (Default 20 minutes) 355 355 ))) 356 356 436 +((( 437 +Range (4 Bytes) : 0x00000000~~ 0xFFFFFFFF . 438 +))) 357 357 358 -=== 2.3.6 Decode payload in The Things Network === 440 +* ((( 441 +(% style="color:#037691" %)**MOD: Default =0** 442 +))) 359 359 444 +((( 445 +MOD=0 ~-~-> Uplink Total Pulse since factory 446 +))) 360 360 361 -While using TTN network, you can add the payload format to decode the payload. 448 +((( 449 +MOD=1 ~-~-> Uplink total pulse since last FPORT=2 uplink. 450 +))) 362 362 363 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDDS75%20-%20LoRaWAN%20Distance%20Detection%20Sensor%20User%20Manual/WebHome/1654850829385-439.png?rev=1.1||alt="1654850829385-439.png"]] 452 +* ((( 453 +(% style="color:#037691" %)**Water Flow Value** 454 +))) 364 364 365 -The payload decoder function for TTN V3 is here: 456 +((( 457 +**Total Water Flow Volume = (Calculate Flag) x (Total Pulse)=9597/450=21.3L** 458 +))) 366 366 460 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/SW3L%20LoRaWAN%20Outdoor%20Flow%20Sensor/WebHome/image-20220519095946-5.png?width=727&height=50&rev=1.1||alt="image-20220519095946-5.png"]] 461 + 462 + 367 367 ((( 368 - DDS75-LBTTNV3 PayloadDecoder: [[ttps:~~/~~/github.com/dragino/dragino-end-node-decoder>>https://github.com/dragino/dragino-end-node-decoder]]464 +**Total Water Flow for TDC timer = (Calculate Flag) x (Last Pulse)=79/450=0.2L** 369 369 ))) 370 370 467 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/SW3L%20LoRaWAN%20Outdoor%20Flow%20Sensor/WebHome/image-20220519095946-6.png?width=733&height=43&rev=1.1||alt="image-20220519095946-6.png"]] ** ** 371 371 372 -== 2.4 Uplink Interval == 373 373 470 +=== 2.3.4 Historical Water Flow Status, FPORT~=3 === 374 374 375 -The DDS75-LB by default uplink the sensor data every 20 minutes. User can change this interval by AT Command or LoRaWAN Downlink Command. See this link: [[Change Uplink Interval>>doc:Main.End Device AT Commands and Downlink Command.WebHome||anchor="H4.1ChangeUplinkInterval"]] 376 376 473 +((( 474 +SW3L-LB stores sensor values and users can retrieve these history values via the [[downlink command>>||anchor="H2.5DatalogFeature"]]. 475 +))) 377 377 378 -== 2.5 Show Data in DataCake IoT Server == 477 +((( 478 +The historical payload includes one or multiplies entries and every entry has the same payload as Real-Time water flow status. 479 +))) 379 379 481 +* ((( 482 +Each data entry is 11 bytes and has the same structure as [[real time water flow status>>||anchor="H2.3.3A0WaterFlowValue2CUplinkFPORT3D2"]], to save airtime and battery, SW3L will send max bytes according to the current DR and Frequency bands. 483 +))) 380 380 381 381 ((( 382 - [[DATACAKE>>url:https://datacake.co/]] providesahuman friendlyinterfaceto show thesensordata, once we havedata in TTN,wecanuse [[DATACAKE>>url:https://datacake.co/]] to connect to TTNandseethedatain DATACAKE. Below arehesteps:486 +For example, in the US915 band, the max payload for different DR is: 383 383 ))) 384 384 385 385 ((( 386 - 490 +(% style="color:blue" %)**a) DR0:**(%%) max is 11 bytes so one entry of data 387 387 ))) 388 388 389 389 ((( 390 -(% style="color:blue" %)** Step1**(%%)**:Besurethatyourdevice isprogrammedandproperly connectedto thenetwork atthistime.**494 +(% style="color:blue" %)**b) DR1:**(%%) max is 53 bytes so devices will upload 4 entries of data (total 44 bytes) 391 391 ))) 392 392 393 393 ((( 394 -(% style="color:blue" %)** Step2**(%%)**:To configurethe Applicationto forwarddata to DATACAKEyou will need todintegration. To add theDATACAKEintegration, performthe followingsteps:**498 +(% style="color:blue" %)**c) DR2:**(%%) total payload includes 11 entries of data 395 395 ))) 396 396 501 +((( 502 +(% style="color:blue" %)**d) DR3:**(%%) total payload includes 22 entries of data. 503 +))) 397 397 398 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDDS75%20-%20LoRaWAN%20Distance%20Detection%20Sensor%20User%20Manual/WebHome/1654592790040-760.png?rev=1.1||alt="1654592790040-760.png"]] 505 +((( 506 +If SW3L-LB doesn't have any data in the polling time. It will uplink 11 bytes of 0 507 +))) 399 399 509 +((( 510 +(% style="color:#037691" %)**Downlink:** 511 +))) 400 400 401 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDDS75%20-%20LoRaWAN%20Distance%20Detection%20Sensor%20User%20Manual/WebHome/1654592800389-571.png?rev=1.1||alt="1654592800389-571.png"]] 513 +((( 514 +0x31 62 46 B1 F0 62 46 B3 94 07 515 +))) 402 402 517 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/SW3L%20LoRaWAN%20Outdoor%20Flow%20Sensor/WebHome/1652926690850-712.png?width=726&height=115&rev=1.1||alt="1652926690850-712.png"]] 403 403 404 -(% style="color:blue" %)**Step 3**(%%)**: Create an account or log in Datacake.** 405 405 406 -(% style="color:blue" %)**Step 4**(%%)**: Search the DDS75-LB and add DevEUI.** 520 +((( 521 +(% style="color:#037691" %)**Uplink:** 522 +))) 407 407 408 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDDS75%20-%20LoRaWAN%20Distance%20Detection%20Sensor%20User%20Manual/WebHome/1654851029373-510.png?rev=1.1||alt="1654851029373-510.png"]] 524 +((( 525 +00 00 01 00 00 00 00 62 46 B2 26 00 00 01 00 00 00 00 62 46 B2 5D 00 00 01 00 00 00 00 62 46 B2 99 00 00 01 00 00 00 00 62 46 B2 D5 00 00 01 00 00 01 15 62 46 B3 11 00 00 01 00 00 01 1F 62 46 B3 7E 526 +))) 409 409 528 +((( 529 +(% style="color:#037691" %)**Parsed Value:** 530 +))) 410 410 411 -After added, the sensor data arrive TTN V3, it will also arrive and show in Datacake. 532 +((( 533 +[Alarm, Calculate Flag, MOD, Total pulse or Last Pulse,** **Water Flow Value, TIME] 534 +))) 412 412 413 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDDS75%20-%20LoRaWAN%20Distance%20Detection%20Sensor%20User%20Manual/WebHome/image-20220610165129-11.png?width=1088&height=595&rev=1.1||alt="image-20220610165129-11.png"]] 414 414 537 +((( 538 +[FALSE,0,0,0,0.0,2022-04-01 08:04:54], 539 +))) 415 415 541 +((( 542 +[FALSE,0,0,0,0.0,2022-04-01 08:05:49], 543 +))) 416 416 417 -== 2.6 Datalog Feature == 545 +((( 546 +[FALSE,0,0,0,0.0,2022-04-01 08:06:49], 547 +))) 418 418 549 +((( 550 +[FALSE,0,0,0,0.0,2022-04-01 08:07:49], 551 +))) 419 419 420 -Datalog Feature is to ensure IoT Server can get all sampling data from Sensor even if the LoRaWAN network is down. For each sampling, DDS75-LB will store the reading for future retrieving purposes. 553 +((( 554 +[FALSE,0,0,277,0.6,2022-04-01 08:08:49], 555 +))) 421 421 557 +((( 558 +[FALSE,0,0,287,0.6,2022-04-01 08:10:38], 559 +))) 422 422 423 - === 2.6.1 Ways togettalog via561 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/SW3L%20LoRaWAN%20Outdoor%20Flow%20Sensor/WebHome/1652926777796-267.png?width=724&height=279&rev=1.1||alt="1652926777796-267.png"]] 424 424 425 425 426 - Set PNACKMD=1,DDS75-LBwill wait for ACK for everyuplink, when there is noLoRaWANnetwork,DDS75-LB will mark these records with non-ack messages and storethe sensor data, andit will sendall messages (10s interval) after the network recovery.564 +== 2.4 Payload Decoder file == 427 427 566 + 567 +In TTN, use can add a custom payload so it shows friendly reading 568 + 569 +In the page (% style="color:#037691" %)**Applications ~-~-> Payload Formats ~-~-> Custom ~-~-> decoder**(%%) to add the decoder from: [[https:~~/~~/github.com/dragino/dragino-end-node-decoder>>https://github.com/dragino/dragino-end-node-decoder]] 570 + 571 + 572 +== 2.5 Datalog Feature == 573 + 574 + 575 +Datalog Feature is to ensure IoT Server can get all sampling data from Sensor even if the LoRaWAN network is down. For each sampling, SW3L-LB will store the reading for future retrieving purposes. 576 + 577 + 578 +=== 2.5.1 Ways to get datalog via LoRaWAN === 579 + 580 + 581 +Set PNACKMD=1, SW3L-LB will wait for ACK for every uplink, when there is no LoRaWAN network,SW3L-LB will mark these records with non-ack messages and store the sensor data, and it will send all messages (10s interval) after the network recovery. 582 + 428 428 * ((( 429 -a) DDS75-LB will do an ACK check for data records sending to make sure every data arrive server.584 +a) SW3L-LB will do an ACK check for data records sending to make sure every data arrive server. 430 430 ))) 431 431 * ((( 432 -b) DDS75-LB will send data in **CONFIRMED Mode** when PNACKMD=1, butDDS75-LB won't re-transmit the packet if it doesn't get ACK, it will just mark it as a NONE-ACK message. In a future uplink ifDDS75-LB gets a ACK,DDS75-LB will consider there is a network connection and resend all NONE-ACK messages.587 +b) SW3L-LB will send data in **CONFIRMED Mode** when PNACKMD=1, but SW3L-LB won't re-transmit the packet if it doesn't get ACK, it will just mark it as a NONE-ACK message. In a future uplink if SW3L-LB gets a ACK, SW3L-LB will consider there is a network connection and resend all NONE-ACK messages. 433 433 ))) 434 434 435 435 Below is the typical case for the auto-update datalog feature (Set PNACKMD=1) ... ... @@ -437,10 +437,10 @@ 437 437 [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/WebHome/image-20220703111700-2.png?width=1119&height=381&rev=1.1||alt="图片-20220703111700-2.png" height="381" width="1119"]] 438 438 439 439 440 -=== 2. 6.2 Unix TimeStamp ===595 +=== 2.5.2 Unix TimeStamp === 441 441 442 442 443 - DDS75-LB uses Unix TimeStamp format based on598 +SW3L-LB uses Unix TimeStamp format based on 444 444 445 445 [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/WebHome/image-20220523001219-11.png?width=627&height=97&rev=1.1||alt="图片-20220523001219-11.png" height="97" width="627"]] 446 446 ... ... @@ -454,17 +454,17 @@ 454 454 So, we can use AT+TIMESTAMP=1611889405 or downlink 3060137afd00 to set the current time 2021 – Jan ~-~- 29 Friday 03:03:25 455 455 456 456 457 -=== 2. 6.3 Set Device Time ===612 +=== 2.5.3 Set Device Time === 458 458 459 459 460 460 User need to set (% style="color:blue" %)**SYNCMOD=1**(%%) to enable sync time via MAC command. 461 461 462 -Once DDS75-LB Joined LoRaWAN network, it will send the MAC command (DeviceTimeReq) and the server will reply with (DeviceTimeAns) to send the current time toDDS75-LB. IfDDS75-LB fails to get the time from the server,DDS75-LB will use the internal time and wait for next time request (AT+SYNCTDC to set the time request period, default is 10 days).617 +Once SW3L-LB Joined LoRaWAN network, it will send the MAC command (DeviceTimeReq) and the server will reply with (DeviceTimeAns) to send the current time to SW3L-LB. If SW3L-LB fails to get the time from the server, SW3L-LB will use the internal time and wait for next time request (AT+SYNCTDC to set the time request period, default is 10 days). 463 463 464 464 (% style="color:red" %)**Note: LoRaWAN Server need to support LoRaWAN v1.0.3(MAC v1.0.3) or higher to support this MAC command feature, Chirpstack,TTN V3 v3 and loriot support but TTN V3 v2 doesn't support. If server doesn't support this command, it will through away uplink packet with this command, so user will lose the packet with time request for TTN V3 v2 if SYNCMOD=1.** 465 465 466 466 467 -=== 2. 6.4 Poll sensor value ===622 +=== 2.5.4 Poll sensor value === 468 468 469 469 470 470 Users can poll sensor values based on timestamps. Below is the downlink command. ... ... @@ -487,24 +487,24 @@ 487 487 ))) 488 488 489 489 ((( 490 -Uplink Internal =5s,means DDS75-LB will send one packet every 5s. range 5~~255s.645 +Uplink Internal =5s,means SW3L-LB will send one packet every 5s. range 5~~255s. 491 491 ))) 492 492 493 493 494 -== 2. 7Frequency Plans ==649 +== 2.6 Frequency Plans == 495 495 496 496 497 -The DDS75-LB uses OTAA mode and below frequency plans by default. If user want to use it with different frequency plan, please refer the AT command sets.652 +The SW3L-LB uses OTAA mode and below frequency plans by default. If user want to use it with different frequency plan, please refer the AT command sets. 498 498 499 499 [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20Frequency%20Band/>>http://wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20Frequency%20Band/]] 500 500 501 501 502 -= 3. Configure DDS75-LB =657 += 3. Configure SW3L-LB = 503 503 504 504 == 3.1 Configure Methods == 505 505 506 506 507 - DDS75-LB supports below configure method:662 +SW3L-LB supports below configure method: 508 508 509 509 * AT Command via Bluetooth Connection (**Recommended**): [[BLE Configure Instruction>>http://wiki.dragino.com/xwiki/bin/view/Main/BLE%20Bluetooth%20Remote%20Configure/]]. 510 510 ... ... @@ -512,6 +512,7 @@ 512 512 513 513 * LoRaWAN Downlink. Instruction for different platforms: See [[IoT LoRaWAN Server>>http://wiki.dragino.com/xwiki/bin/view/Main/]] section. 514 514 670 + 515 515 == 3.2 General Commands == 516 516 517 517 ... ... @@ -526,10 +526,10 @@ 526 526 [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/>>http://wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/]] 527 527 528 528 529 -== 3.3 Commands special design for DDS75-LB ==685 +== 3.3 Commands special design for SW3L-LB == 530 530 531 531 532 -These commands only valid for DDS75-LB, as below:688 +These commands only valid for SW3L-LB, as below: 533 533 534 534 535 535 === 3.3.1 Set Transmit Interval Time === ... ... @@ -574,9 +574,169 @@ 574 574 Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds 575 575 ))) 576 576 577 -=== 3.3.2 Set Interrupt Mode === 578 578 734 +=== 3.3.2 Quit AT Command === 579 579 736 + 737 +Feature: Quit AT Command mode, so user needs to input the password again before using AT Commands. 738 + 739 +(% style="color:blue" %)**AT Command: AT+DISAT** 740 + 741 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:452px" %) 742 +|=(% style="width: 155px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 198px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 99px;background-color:#D9E2F3;color:#0070C0" %)**Response** 743 +|(% style="width:155px" %)AT+DISAT|(% style="width:198px" %)Quit AT Commands mode|(% style="width:96px" %)OK 744 + 745 +(% style="color:blue" %)**Downlink Command:** 746 + 747 +No downlink command for this feature. 748 + 749 + 750 +=== 3.3.3 Get Device Status === 751 + 752 + 753 +Send a LoRaWAN downlink to ask device send Alarm settings. 754 + 755 +(% style="color:blue" %)**Downlink Payload: **(%%)0x26 01 756 + 757 +Sensor will upload Device Status via FPORT=5. See payload section for detail. 758 + 759 + 760 +=== 3.3.4 Alarm for continuously water flow === 761 + 762 + 763 +((( 764 +This feature is to monitor and send Alarm for continuously water flow. 765 +))) 766 + 767 +((( 768 +Example case is for Toilet water monitoring, if some one push toilet button, the toilet will have water flow. If the toilet button has broken and can't returned to original state, the water flow will keep for hours or days which cause huge waste for water. 769 +))) 770 + 771 +((( 772 +To monitor this faulty and send alarm, there are two settings: 773 +))) 774 + 775 +* ((( 776 +(% style="color:#4f81bd" %)**Stop Duration: Unit: Second** 777 +))) 778 + 779 +((( 780 +Default: 15s, If SW3L-LB didn't see any water flow in 15s, SW3L-LB will consider stop of water flow event. 781 +))) 782 + 783 +* ((( 784 +(% style="color:#4f81bd" %)**Alarm Timer: Units: Minute; Default 0 minutes (means Alarm disable)** 785 +))) 786 + 787 +((( 788 +**Example:** 3 minutes, if SW3L-LB detect a start of water flow event and didn't detect a stop event within Alarm timer, SW3L-LB will send an Alarm to indicate a water flow abnormal alarm. 789 +))) 790 + 791 +((( 792 +So for example, If we set stop duration=15s and Alarm Timer=3minutes. If the toilet water flow continuously for more than 3 minutes, Sensor will send an alarm (in Confirmed MODE) to platform. 793 +))) 794 + 795 +((( 796 +(% style="color:red" %)**Note:** **After this alarm is send, sensor will consider a stop of water flow and count for another new event. So if water flow waste last for 1 hour, Sensor will keep sending alarm every 3 minutes.** 797 +))) 798 + 799 +((( 800 +(% style="color:#4f81bd" %)**AT Command**(%%) to configure: 801 +))) 802 + 803 +* ((( 804 +AT+PTRIG=15,3 ~-~-> Set Stop duration: 15s, Alarm Timer: 3 minutes. 805 +))) 806 + 807 +* ((( 808 +AT+ PTRIG=15,0 ~-~-> Default Value, disable water waste Alarm. 809 +))) 810 + 811 +((( 812 +(% style="color:#4f81bd" %)**Downlink Command**(%%) to configure: 813 +))) 814 + 815 +((( 816 +Command: **0xAA aa bb cc** 817 +))) 818 + 819 +((( 820 +AA: Command Type Code 821 +))) 822 + 823 +((( 824 +aa: Stop duration 825 +))) 826 + 827 +((( 828 +bb cc: Alarm Timer 829 +))) 830 + 831 +((( 832 +If user send 0xAA 0F 00 03: equal to AT+PTRIG=15,3 833 +))) 834 + 835 + 836 +=== 3.3.5 Clear Flash Record === 837 + 838 + 839 +Feature: Clear flash storage for data log feature. 840 + 841 +(% style="color:blue" %)**AT Command: AT+CLRDTA** 842 + 843 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:500px" %) 844 +|=(% style="width: 157px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 169px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 174px;background-color:#D9E2F3;color:#0070C0" %)**Response** 845 +|(% style="width:157px" %)AT+CLRDTA|(% style="width:169px" %)Clear flash storage for data log feature.|Clear all stored sensor data… OK 846 + 847 +((( 848 +(% style="color:blue" %)**Downlink Command:** 849 +))) 850 + 851 +((( 852 +* **Example**: 0xA301 ~/~/ Same as AT+CLRDTA 853 +))) 854 + 855 + 856 + 857 +=== 3.3.6 Set the calculate flag === 858 + 859 + 860 +Feature: Set the calculate flag 861 + 862 +(% style="color:blue" %)**AT Command: AT+CALCFLAG** 863 + 864 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:461px" %) 865 +|=(% style="width: 158px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 193px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 110px;background-color:#D9E2F3;color:#0070C0" %)**Response** 866 +|(% style="width:158px" %)AT+CALCFLAG =1|(% style="width:192px" %)Set the calculate flag to 1.|(% style="width:109px" %)OK 867 +|(% style="width:158px" %)AT+CALCFLAG =2|(% style="width:192px" %)Set the calculate flag to 2.|(% style="width:109px" %)OK 868 + 869 +(% style="color:blue" %)**Downlink Command:** 870 + 871 +* **Example**: 0XA501 ~/~/ Same as AT+CALCFLAG =1 872 + 873 + 874 +=== 3.3.7 Set count number === 875 + 876 + 877 +Feature: Manually set the count number 878 + 879 +(% style="color:blue" %)**AT Command: AT+SETCNT** 880 + 881 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:479px" %) 882 +|=(% style="width: 160px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 223px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 96px;background-color:#D9E2F3;color:#0070C0" %)**Response** 883 +|(% style="width:160px" %)AT+ SETCNT =0|(% style="width:221px" %)Set the count number to 0.|(% style="width:95px" %)OK 884 +|(% style="width:160px" %)AT+ SETCNT =100|(% style="width:221px" %)Set the count number to 100.|(% style="width:95px" %)OK 885 + 886 +(% style="color:blue" %)**Downlink Command:** 887 + 888 +* **Example**: 0xA6000001 ~/~/ Same as AT+ SETCNT =1 889 + 890 +* **Example**: 0xA6000064 ~/~/ Same as AT+ SETCNT =100 891 + 892 + 893 +=== 3.3.8 Set Interrupt Mode === 894 + 895 + 580 580 Feature, Set Interrupt mode for PA8 of pin. 581 581 582 582 When AT+INTMOD=0 is set, PA8 is used as a digital input port. ... ... @@ -608,101 +608,71 @@ 608 608 609 609 * Example 2: Downlink Payload: 06000003 ~/~/ Set the interrupt mode to rising edge trigger 610 610 611 -= 4. Battery & Power Consumption = 612 612 928 +=== 3.3.9 Set work mode === 613 613 614 -DDS75-LB use ER26500 + SPC1520 battery pack. See below link for detail information about the battery info and how to replace. 615 615 616 - [[**Battery Info & PowerConsumption Analyze**>>http://wiki.dragino.com/xwiki/bin/view/Main/How%20to%20calculate%20the%20battery%20life%20of%20Dragino%20sensors%3F/]] .931 +Feature: Manually set the work mode 617 617 618 618 619 -= 5. OTAFirmware update=934 +(% style="color:blue" %)**AT Command: AT+MOD** 620 620 936 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:463px" %) 937 +|=(% style="width: 162px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 193px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 108px;background-color:#D9E2F3;color:#0070C0" %)**Response** 938 +|(% style="width:162px" %)AT+MOD=0|(% style="width:191px" %)Set the work mode to 0.|(% style="width:106px" %)OK 939 +|(% style="width:162px" %)AT+MOD=1|(% style="width:191px" %)Set the work mode to 1|(% style="width:106px" %)OK 621 621 622 -(% class="wikigeneratedid" %) 623 -User can change firmware DDS75-LB to: 941 +(% style="color:blue" %)**Downlink Command:** 624 624 625 -* ChangeFrequencyband/region.943 +* **Example: **0x0A00 ~/~/ Same as AT+MOD=0 626 626 627 -* Updatewithnewfeatures.945 +* **Example:** 0x0A01 ~/~/ Same as AT+MOD=1 628 628 629 -* Fix bugs. 630 630 631 - Firmwareandchangelogcanbe downloaded from: **[[Firmware download link>>url:https://www.dropbox.com/sh/7la95mae0fn03xe/AACtzs-32m22TLb75B-iIr-Qa?dl=0]]**948 += 4. Battery & Power Consumption = 632 632 633 -Methods to Update Firmware: 634 634 635 - *(Recommandedway)OTAfirmwareupdateviawireless: [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/Firmware%20OTA%20Update%20for%20Sensors/>>url:http://wiki.dragino.com/xwiki/bin/view/Main/Firmware%20OTA%20Update%20for%20Sensors/]]951 +SW3L-LB use ER26500 + SPC1520 battery pack. See below link for detail information about the battery info and how to replace. 636 636 637 -* UpdatethroughUARTTTL interface: **[[Instruction>>url:http://wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H1.LoRaSTv4baseHardware]]**.953 +[[**Battery Info & Power Consumption Analyze**>>http://wiki.dragino.com/xwiki/bin/view/Main/How%20to%20calculate%20the%20battery%20life%20of%20Dragino%20sensors%3F/]] . 638 638 639 -= 6. FAQ = 640 640 956 += 5. OTA Firmware update = 641 641 642 -== 6.1 What is the frequency plan for DDS75-LB? == 643 643 959 +(% class="wikigeneratedid" %) 960 +User can change firmware SW3L-LB to: 644 644 645 - DDS75-LBuse the same frequency as other Dragino products. Usercan see the detail from this link: [[Introduction>>doc:Main.End DeviceFrequencyBand.WebHome||anchor="H1.Introduction"]]962 +* Change Frequency band/ region. 646 646 964 +* Update with new features. 647 647 648 - ==6.2Can IuseDDS75-LB in condensation environment? ==966 +* Fix bugs. 649 649 968 +Firmware and changelog can be downloaded from : **[[Firmware download link>>url:https://www.dropbox.com/sh/kwqv57tp6pejias/AAAopYMATh1GM6fZ-VRCLrpDa?dl=0]]** 650 650 651 - DDS75-LB is not suitablebe usedin condensationenvironment. Condensation on theDDS75-LB probewillaffect thereading and always got 0.970 +Methods to Update Firmware: 652 652 972 +* (Recommanded way) OTA firmware update via wireless: [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/Firmware%20OTA%20Update%20for%20Sensors/>>url:http://wiki.dragino.com/xwiki/bin/view/Main/Firmware%20OTA%20Update%20for%20Sensors/]] 653 653 654 - =7.Trouble Shooting =974 +* Update through UART TTL interface. **[[Instruction>>url:http://wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H1.LoRaSTv4baseHardware]]**. 655 655 656 -== 7.1 Why I can't join TTN V3 in US915 / AU915 bands? == 657 657 977 += 6. FAQ = 658 658 659 - Itisduetochannelmapping. Pleasesee below link: [[Frequencyband>>doc:Main.LoRaWAN CommunicationDebug.WebHome||anchor="H2.NoticeofUS9152FCN4702FAU915Frequencyband"]]979 +== 6.1 AT Commands input doesn't work == 660 660 661 661 662 - ==7.2ATCommand input doesn'twork==982 +In the case if user can see the console output but can't type input to the device. Please check if you already include the (% style="color:green" %)**ENTER**(%%) while sending out the command. Some serial tool doesn't send (% style="color:green" %)**ENTER**(%%) while press the send key, user need to add ENTER in their string. 663 663 664 664 665 - In the case if user can see the console output but can't type input to the device. Please check if you already include the (% style="color:blue"%)**ENTER**(%%) while sending out the command.Some serial tooldoesn't send (% style="color:blue"%)**ENTER**(%%) while press the send key, user need toadd ENTER in their string.985 += 7. Order Info = 666 666 667 667 668 - == 7.3 Why doesthesensorreadingshow 0 or"Nosensor"==988 +Part Number: (% style="color:blue" %)**SW3L-LB-XXX-YYY** 669 669 990 +(% style="color:red" %)**XXX**(%%): The default frequency band 670 670 671 -~1. The measurement object is very close to the sensor, but in the blind spot of the sensor. 672 - 673 -2. Sensor wiring is disconnected 674 - 675 -3. Not using the correct decoder 676 - 677 - 678 -== 7.4 Abnormal readings The gap between multiple readings is too large or the gap between the readings and the actual value is too large == 679 - 680 - 681 -1) Please check if there is something on the probe affecting its measurement (condensed water, volatile oil, etc.) 682 - 683 -2) Does it change with temperature, temperature will affect its measurement 684 - 685 -3) If abnormal data occurs, you can turn on DEBUG mode, Please use downlink or AT COMMAN to enter DEBUG mode. 686 - 687 -downlink command: (% style="color:blue" %)**F1 01**(%%), AT command: (% style="color:blue" %)**AT+DDEBUG=1** 688 - 689 -4) After entering the debug mode, it will send 20 pieces of data at a time, and you can send its uplink to us for analysis 690 - 691 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDDS75%20-%20LoRaWAN%20Distance%20Detection%20Sensor%20User%20Manual/WebHome/image-20230113135125-2.png?width=1057&height=136&rev=1.1||alt="image-20230113135125-2.png"]] 692 - 693 - 694 -Its original payload will be longer than other data. Even though it is being parsed, it can be seen that it is abnormal data. 695 - 696 -Please send the data to us for check. 697 - 698 - 699 -= 8. Order Info = 700 - 701 - 702 -Part Number: (% style="color:blue" %)**DDS75-LB-XXX** 703 - 704 -(% style="color:red" %)**XXX**(%%): **The default frequency band** 705 - 706 706 * (% style="color:red" %)**AS923**(%%): LoRaWAN AS923 band 707 707 708 708 * (% style="color:red" %)**AU915**(%%): LoRaWAN AU915 band ... ... @@ -719,13 +719,43 @@ 719 719 720 720 * (% style="color:red" %)**CN470**(%%): LoRaWAN CN470 band 721 721 1008 +((( 1009 +(% style="color:blue" %)**YYY**(%%): Flow Sensor Model: 1010 +))) 722 722 723 -= 9. Packing Info = 1012 +((( 1013 + **004:** DW-004 Flow Sensor: diameter: G1/2” / DN15. 450 pulse = 1 L 1014 +))) 724 724 1016 +((( 1017 + **006:** DW-006 Flow Sensor: diameter: G3/4” / DN20. 390 pulse = 1 L 1018 +))) 725 725 1020 +((( 1021 + **010:** DW-010 Flow Sensor: diameter: G 1” / DN25. 64 pulse = 1 L 1022 +))) 1023 + 1024 +* ((( 1025 +calculate flag=0: for SW3L-004 Flow Sensor: 450 pulse = 1 L 1026 +))) 1027 + 1028 +* ((( 1029 +calculate flag=1: for SW3L-006 Flow Sensor: 390 pulse = 1 L 1030 +))) 1031 + 1032 +* ((( 1033 +calculate flag=2: for SW3L-010 Flow Sensor: 64 pulse = 1 L 1034 + 1035 + 1036 + 1037 +))) 1038 + 1039 += 8. Packing Info = 1040 + 1041 + 726 726 (% style="color:#037691" %)**Package Includes**: 727 727 728 -* DDS75-LB LoRaWANDistance DetectionSensorx 11044 +* SW3L-LB LoRaWAN Flow Sensor 729 729 730 730 (% style="color:#037691" %)**Dimension and weight**: 731 731 ... ... @@ -738,7 +738,7 @@ 738 738 * Weight / pcs : g 739 739 740 740 741 -= 10. Support =1057 += 9. Support = 742 742 743 743 744 744 * Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule.