Changes for page DS20L -- LoRaWAN Smart Distance Detector User Manual 01
Last modified by Mengting Qiu on 2023/12/14 11:15
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -22,13 +22,13 @@ 22 22 23 23 It detects the distance(% style="color:blue" %)** between the measured object and the sensor**(%%), and uploads the value via wireless to LoRaWAN IoT Server. 24 24 25 -The LoRa wireless technology used in DDS75-LB allows device to send data and reach extremely long ranges at low data-rates. It provides ultra-long range spread spectrum communication and high interference immunity whilst minimizing current consumption.25 +The LoRa wireless technology used in SW3L-LB allows device to send data and reach extremely long ranges at low data-rates. It provides ultra-long range spread spectrum communication and high interference immunity whilst minimizing current consumption. 26 26 27 - DDS75-LB (% style="color:blue" %)**supports BLE configure**(%%) and (% style="color:blue" %)**wireless OTA update**(%%) which make user easy to use.27 +SW3L-LB (% style="color:blue" %)**supports BLE configure**(%%) and (% style="color:blue" %)**wireless OTA update**(%%) which make user easy to use. 28 28 29 - DDS75-LB is powered by (% style="color:blue" %)**8500mAh Li-SOCI2 battery**(%%), it is designed for long term use up to 5 years.29 +SW3L-LB is powered by (% style="color:blue" %)**8500mAh Li-SOCI2 battery**(%%), it is designed for long term use up to 5 years. 30 30 31 -Each DDS75-LB is pre-load with a set of unique keys for LoRaWAN registrations, register these keys to local LoRaWAN server and it will auto connect after power on.31 +Each SW3L-LB is pre-load with a set of unique keys for LoRaWAN registrations, register these keys to local LoRaWAN server and it will auto connect after power on. 32 32 33 33 [[image:image-20230612170943-2.png||height="525" width="912"]] 34 34 ... ... @@ -73,9 +73,9 @@ 73 73 )))|(% style="width:66px" %)65%|(% style="width:90px" %)80%|(% style="width:48px" %)RH|(% style="width:203px" %)(1) 74 74 75 75 ((( 76 - (% style="color:red" %)**Remarks: (1) a. When the ambient temperature is 0-39 ℃, the maximum humidity is 90% (non-condensing); **76 +**Remarks: (1) a. When the ambient temperature is 0-39 ℃, the maximum humidity is 90% (non-condensing); ** 77 77 78 - (% style="color:red" %)** b. When the ambient temperature is 40-50 ℃, the highest humidity is the highest humidity in the natural world at the current temperature (no condensation)**78 +**~ b. When the ambient temperature is 40-50 ℃, the highest humidity is the highest humidity in the natural world at the current temperature (no condensation)** 79 79 80 80 81 81 ))) ... ... @@ -108,12 +108,12 @@ 108 108 == 1.4 Effective measurement range Reference beam pattern == 109 109 110 110 111 - (% style="color:blue" %)**1. The tested object is a white cylindrical tube made of PVC, with a height of 100cm and a diameter of 7.5cm.**111 +**~1. The tested object is a white cylindrical tube made of PVC, with a height of 100cm and a diameter of 7.5cm.** 112 112 113 113 [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDDS75%20-%20LoRaWAN%20Distance%20Detection%20Sensor%20User%20Manual/WebHome/1654852253176-749.png?rev=1.1||alt="1654852253176-749.png"]] 114 114 115 115 116 - (% style="color:blue" %)**2. The object to be tested is a "corrugated cardboard box" perpendicular to the central axis of 0 °, and the length * width is 60cm * 50cm.**116 +**2. The object to be tested is a "corrugated cardboard box" perpendicular to the central axis of 0 °, and the length * width is 60cm * 50cm.** 117 117 118 118 [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDDS75%20-%20LoRaWAN%20Distance%20Detection%20Sensor%20User%20Manual/WebHome/1654852175653-550.png?rev=1.1||alt="1654852175653-550.png"]] 119 119 ... ... @@ -178,8 +178,8 @@ 178 178 [[image:image-20230523174230-1.png]] 179 179 180 180 181 +== == 181 181 182 - 183 183 == 2.10 Mechanical == 184 184 185 185 ... ... @@ -192,7 +192,7 @@ 192 192 [[image:Main.User Manual for LoRaWAN End Nodes.D20-LBD22-LBD23-LB_LoRaWAN_Temperature_Sensor_User_Manual.WebHome@1675143909447-639.png]] 193 193 194 194 195 - (% style="color:blue" %)**Probe Mechanical:**195 +**Probe Mechanical:** 196 196 197 197 198 198 [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDDS75%20-%20LoRaWAN%20Distance%20Detection%20Sensor%20User%20Manual/WebHome/image-20220610172003-1.png?rev=1.1||alt="image-20220610172003-1.png"]] ... ... @@ -268,6 +268,7 @@ 268 268 269 269 270 270 ((( 271 +((( 271 271 DDS75-LB will uplink payload via LoRaWAN with below payload format: 272 272 ))) 273 273 ... ... @@ -275,9 +275,12 @@ 275 275 Uplink payload includes in total 4 bytes. 276 276 Payload for firmware version v1.1.4. . Before v1.1.3, there is on two fields: BAT and Distance 277 277 ))) 279 +))) 278 278 281 +((( 282 + 283 +))) 279 279 280 - 281 281 (% border="1" cellspacing="5" style="background-color:#f2f2f2; width:510px" %) 282 282 |=(% style="width: 62.5px;background-color:#D9E2F3;color:#0070C0" %)((( 283 283 **Size(bytes)** ... ... @@ -319,7 +319,6 @@ 319 319 * If the sensor value is 0x0000, it means system doesn't detect ultrasonic sensor. 320 320 * If the sensor value lower than 0x0118 (280mm), the sensor value will be invalid. Since v1.1.4, all value lower than 280mm will be set to 0x0014(20mm) which means the value is invalid. 321 321 322 - 323 323 === 2.3.3 Interrupt Pin === 324 324 325 325 ... ... @@ -420,19 +420,19 @@ 420 420 == 2.6 Datalog Feature == 421 421 422 422 423 -Datalog Feature is to ensure IoT Server can get all sampling data from Sensor even if the LoRaWAN network is down. For each sampling, DDS75-LB will store the reading for future retrieving purposes.426 +Datalog Feature is to ensure IoT Server can get all sampling data from Sensor even if the LoRaWAN network is down. For each sampling, SW3L-LB will store the reading for future retrieving purposes. 424 424 425 425 426 426 === 2.6.1 Ways to get datalog via LoRaWAN === 427 427 428 428 429 -Set PNACKMD=1, DDS75-LB will wait for ACK for every uplink, when there is no LoRaWAN network,DDS75-LB will mark these records with non-ack messages and store the sensor data, and it will send all messages (10s interval) after the network recovery.432 +Set PNACKMD=1, SW3L-LB will wait for ACK for every uplink, when there is no LoRaWAN network,SW3L-LB will mark these records with non-ack messages and store the sensor data, and it will send all messages (10s interval) after the network recovery. 430 430 431 431 * ((( 432 -a) DDS75-LB will do an ACK check for data records sending to make sure every data arrive server.435 +a) SW3L-LB will do an ACK check for data records sending to make sure every data arrive server. 433 433 ))) 434 434 * ((( 435 -b) DDS75-LB will send data in **CONFIRMED Mode** when PNACKMD=1, butDDS75-LB won't re-transmit the packet if it doesn't get ACK, it will just mark it as a NONE-ACK message. In a future uplink ifDDS75-LB gets a ACK,DDS75-LB will consider there is a network connection and resend all NONE-ACK messages.438 +b) SW3L-LB will send data in **CONFIRMED Mode** when PNACKMD=1, but SW3L-LB won't re-transmit the packet if it doesn't get ACK, it will just mark it as a NONE-ACK message. In a future uplink if SW3L-LB gets a ACK, SW3L-LB will consider there is a network connection and resend all NONE-ACK messages. 436 436 ))) 437 437 438 438 Below is the typical case for the auto-update datalog feature (Set PNACKMD=1) ... ... @@ -443,7 +443,7 @@ 443 443 === 2.6.2 Unix TimeStamp === 444 444 445 445 446 - DDS75-LB uses Unix TimeStamp format based on449 +SW3L-LB uses Unix TimeStamp format based on 447 447 448 448 [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/WebHome/image-20220523001219-11.png?width=627&height=97&rev=1.1||alt="图片-20220523001219-11.png" height="97" width="627"]] 449 449 ... ... @@ -462,7 +462,7 @@ 462 462 463 463 User need to set (% style="color:blue" %)**SYNCMOD=1**(%%) to enable sync time via MAC command. 464 464 465 -Once DDS75-LB Joined LoRaWAN network, it will send the MAC command (DeviceTimeReq) and the server will reply with (DeviceTimeAns) to send the current time toDDS75-LB. IfDDS75-LB fails to get the time from the server,DDS75-LB will use the internal time and wait for next time request (AT+SYNCTDC to set the time request period, default is 10 days).468 +Once SW3L-LB Joined LoRaWAN network, it will send the MAC command (DeviceTimeReq) and the server will reply with (DeviceTimeAns) to send the current time to SW3L-LB. If SW3L-LB fails to get the time from the server, SW3L-LB will use the internal time and wait for next time request (AT+SYNCTDC to set the time request period, default is 10 days). 466 466 467 467 (% style="color:red" %)**Note: LoRaWAN Server need to support LoRaWAN v1.0.3(MAC v1.0.3) or higher to support this MAC command feature, Chirpstack,TTN V3 v3 and loriot support but TTN V3 v2 doesn't support. If server doesn't support this command, it will through away uplink packet with this command, so user will lose the packet with time request for TTN V3 v2 if SYNCMOD=1.** 468 468 ... ... @@ -490,7 +490,7 @@ 490 490 ))) 491 491 492 492 ((( 493 -Uplink Internal =5s,means DDS75-LB will send one packet every 5s. range 5~~255s.496 +Uplink Internal =5s,means SW3L-LB will send one packet every 5s. range 5~~255s. 494 494 ))) 495 495 496 496 ... ... @@ -497,17 +497,17 @@ 497 497 == 2.7 Frequency Plans == 498 498 499 499 500 -The DDS75-LB uses OTAA mode and below frequency plans by default. If user want to use it with different frequency plan, please refer the AT command sets.503 +The SW3L-LB uses OTAA mode and below frequency plans by default. If user want to use it with different frequency plan, please refer the AT command sets. 501 501 502 502 [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20Frequency%20Band/>>http://wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20Frequency%20Band/]] 503 503 504 504 505 -= 3. Configure DDS75-LB =508 += 3. Configure SW3L-LB = 506 506 507 507 == 3.1 Configure Methods == 508 508 509 509 510 - DDS75-LB supports below configure method:513 +SW3L-LB supports below configure method: 511 511 512 512 * AT Command via Bluetooth Connection (**Recommended**): [[BLE Configure Instruction>>http://wiki.dragino.com/xwiki/bin/view/Main/BLE%20Bluetooth%20Remote%20Configure/]]. 513 513 ... ... @@ -529,10 +529,10 @@ 529 529 [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/>>http://wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/]] 530 530 531 531 532 -== 3.3 Commands special design for DDS75-LB ==535 +== 3.3 Commands special design for SW3L-LB == 533 533 534 534 535 -These commands only valid for DDS75-LB, as below:538 +These commands only valid for SW3L-LB, as below: 536 536 537 537 538 538 === 3.3.1 Set Transmit Interval Time === ... ... @@ -577,135 +577,259 @@ 577 577 Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds 578 578 ))) 579 579 580 -=== 3.3.2 Set InterruptMode===583 +=== 3.3.2 Quit AT Command === 581 581 582 582 583 -Feature ,SetInterruptmodeforPA8of pin.586 +Feature: Quit AT Command mode, so user needs to input the password again before using AT Commands. 584 584 585 - WhenAT+INTMOD=0 isset, PA8 isusedasaigitalinput port.588 +(% style="color:blue" %)**AT Command: AT+DISAT** 586 586 587 -(% style="color:blue" %)**AT Command: AT+INTMOD** 590 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:452px" %) 591 +|=(% style="width: 155px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 198px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 99px;background-color:#D9E2F3;color:#0070C0" %)**Response** 592 +|(% style="width:155px" %)AT+DISAT|(% style="width:198px" %)Quit AT Commands mode|(% style="width:96px" %)OK 588 588 589 -(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %) 590 -|=(% style="width: 155px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 197px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 158px;background-color:#D9E2F3;color:#0070C0" %)**Response** 591 -|(% style="width:154px" %)AT+INTMOD=?|(% style="width:196px" %)Show current interrupt mode|(% style="width:157px" %)((( 592 -0 593 -OK 594 -the mode is 0 =Disable Interrupt 594 +(% style="color:blue" %)**Downlink Command:** 595 + 596 +No downlink command for this feature. 597 + 598 + 599 +=== 3.3.3 Get Device Status === 600 + 601 + 602 +Send a LoRaWAN downlink to ask device send Alarm settings. 603 + 604 +(% style="color:blue" %)**Downlink Payload: **(%%)0x26 01 605 + 606 +Sensor will upload Device Status via FPORT=5. See payload section for detail. 607 + 608 + 609 +=== 3.3.4 Alarm for continuously water flow === 610 + 611 + 612 +((( 613 +This feature is to monitor and send Alarm for continuously water flow. 595 595 ))) 596 -|(% style="width:154px" %)AT+INTMOD=2|(% style="width:196px" %)((( 597 -Set Transmit Interval 598 -0. (Disable Interrupt), 599 -~1. (Trigger by rising and falling edge) 600 -2. (Trigger by falling edge) 601 -3. (Trigger by rising edge) 602 -)))|(% style="width:157px" %)OK 603 603 604 -(% style="color:blue" %)**Downlink Command: 0x06** 616 +((( 617 +Example case is for Toilet water monitoring, if some one push toilet button, the toilet will have water flow. If the toilet button has broken and can't returned to original state, the water flow will keep for hours or days which cause huge waste for water. 618 +))) 605 605 606 -Format: Command Code (0x06) followed by 3 bytes. 620 +((( 621 +To monitor this faulty and send alarm, there are two settings: 622 +))) 607 607 608 -This means that the interrupt mode of the end node is set to 0x000003=3 (rising edge trigger), and the type code is 06. 624 +* ((( 625 +(% style="color:#4f81bd" %)**Stop Duration: Unit: Second** 626 +))) 609 609 610 -* Example 1: Downlink Payload: 06000000 ~/~/ Turn off interrupt mode 628 +((( 629 +Default: 15s, If SW3L-LB didn't see any water flow in 15s, SW3L-LB will consider stop of water flow event. 630 +))) 611 611 612 -* Example 2: Downlink Payload: 06000003 ~/~/ Set the interrupt mode to rising edge trigger 632 +* ((( 633 +(% style="color:#4f81bd" %)**Alarm Timer: Units: Minute; Default 0 minutes (means Alarm disable)** 634 +))) 613 613 614 -= 4. Battery & Power Consumption = 636 +((( 637 +**Example:** 3 minutes, if SW3L-LB detect a start of water flow event and didn't detect a stop event within Alarm timer, SW3L-LB will send an Alarm to indicate a water flow abnormal alarm. 638 +))) 615 615 640 +((( 641 +So for example, If we set stop duration=15s and Alarm Timer=3minutes. If the toilet water flow continuously for more than 3 minutes, Sensor will send an alarm (in Confirmed MODE) to platform. 642 +))) 616 616 617 -DDS75-LB use ER26500 + SPC1520 battery pack. See below link for detail information about the battery info and how to replace. 644 +((( 645 +(% style="color:red" %)**Note:** **After this alarm is send, sensor will consider a stop of water flow and count for another new event. So if water flow waste last for 1 hour, Sensor will keep sending alarm every 3 minutes.** 646 +))) 618 618 619 -[[**Battery Info & Power Consumption Analyze**>>http://wiki.dragino.com/xwiki/bin/view/Main/How%20to%20calculate%20the%20battery%20life%20of%20Dragino%20sensors%3F/]] . 648 +((( 649 +(% style="color:#4f81bd" %)**AT Command**(%%) to configure: 650 +))) 620 620 652 +* ((( 653 +AT+PTRIG=15,3 ~-~-> Set Stop duration: 15s, Alarm Timer: 3 minutes. 654 +))) 621 621 622 -= 5. OTA Firmware update = 656 +* ((( 657 +AT+ PTRIG=15,0 ~-~-> Default Value, disable water waste Alarm. 658 +))) 623 623 660 +((( 661 +(% style="color:#4f81bd" %)**Downlink Command**(%%) to configure: 662 +))) 624 624 625 -(% class="wikigeneratedid" %) 626 -User can change firmware DDS75-LB to: 664 +((( 665 +Command: **0xAA aa bb cc** 666 +))) 627 627 628 -* Change Frequency band/ region. 668 +((( 669 +AA: Command Type Code 670 +))) 629 629 630 -* Update with new features. 672 +((( 673 +aa: Stop duration 674 +))) 631 631 632 -* Fix bugs. 676 +((( 677 +bb cc: Alarm Timer 678 +))) 633 633 634 -Firmware and changelog can be downloaded from : **[[Firmware download link>>url:https://www.dropbox.com/sh/7la95mae0fn03xe/AACtzs-32m22TLb75B-iIr-Qa?dl=0]]** 680 +((( 681 +If user send 0xAA 0F 00 03: equal to AT+PTRIG=15,3 682 +))) 635 635 636 -Methods to Update Firmware: 637 637 638 - *(Recommandedway) OTA firmwareupdate via wireless: [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/Firmware%20OTA%20Update%20for%20Sensors/>>url:http://wiki.dragino.com/xwiki/bin/view/Main/Firmware%20OTA%20Update%20for%20Sensors/]]685 +=== 3.3.5 Clear Flash Record === 639 639 640 -* Update through UART TTL interface: **[[Instruction>>url:http://wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H1.LoRaSTv4baseHardware]]**. 641 641 642 - =6.FAQ=688 +Feature: Clear flash storage for data log feature. 643 643 690 +(% style="color:blue" %)**AT Command: AT+CLRDTA** 644 644 645 -== 6.1 What is the frequency plan for DDS75-LB? == 692 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:500px" %) 693 +|=(% style="width: 157px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 169px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 174px;background-color:#D9E2F3;color:#0070C0" %)**Response** 694 +|(% style="width:157px" %)AT+CLRDTA|(% style="width:169px" %)Clear flash storage for data log feature.|Clear all stored sensor data… OK 646 646 696 +((( 697 +(% style="color:blue" %)**Downlink Command:** 698 +))) 647 647 648 -DDS75-LB use the same frequency as other Dragino products. User can see the detail from this link: [[Introduction>>doc:Main.End Device Frequency Band.WebHome||anchor="H1.Introduction"]] 700 +((( 701 +* **Example**: 0xA301 ~/~/ Same as AT+CLRDTA 702 +))) 649 649 650 650 651 -== 6.2 Can I use DDS75-LB in condensation environment? == 652 652 706 +=== 3.3.6 Set the calculate flag === 653 653 654 -DDS75-LB is not suitable to be used in condensation environment. Condensation on the DDS75-LB probe will affect the reading and always got 0. 655 655 709 +Feature: Set the calculate flag 656 656 657 - =7. TroubleShooting=711 +(% style="color:blue" %)**AT Command: AT+CALCFLAG** 658 658 659 -== 7.1 Why I can't join TTN V3 in US915 / AU915 bands? == 713 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:461px" %) 714 +|=(% style="width: 158px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 193px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 110px;background-color:#D9E2F3;color:#0070C0" %)**Response** 715 +|(% style="width:158px" %)AT+CALCFLAG =1|(% style="width:192px" %)Set the calculate flag to 1.|(% style="width:109px" %)OK 716 +|(% style="width:158px" %)AT+CALCFLAG =2|(% style="width:192px" %)Set the calculate flag to 2.|(% style="width:109px" %)OK 660 660 718 +(% style="color:blue" %)**Downlink Command:** 661 661 662 - Itis due to channelmapping. Pleaseseebelowlink:[[Frequencyband>>doc:Main.LoRaWAN Communication Debug.WebHome||anchor="H2.NoticeofUS9152FCN4702FAU915Frequencyband"]]720 +* **Example**: 0XA501 ~/~/ Same as AT+CALCFLAG =1 663 663 722 +=== 3.3.7 Set count number === 664 664 665 -== 7.2 AT Command input doesn't work == 666 666 725 +Feature: Manually set the count number 667 667 668 - In the case if user can see the console output but can't type input to the device. Please check if you already include the(% style="color:blue" %)**ENTER**(%%)while sendingout the command. Some serial tool doesn't send (% style="color:blue"%)**ENTER**(%%) while press the send key, user need to add ENTER in their string.727 +(% style="color:blue" %)**AT Command: AT+SETCNT** 669 669 729 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:479px" %) 730 +|=(% style="width: 160px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 223px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 96px;background-color:#D9E2F3;color:#0070C0" %)**Response** 731 +|(% style="width:160px" %)AT+ SETCNT =0|(% style="width:221px" %)Set the count number to 0.|(% style="width:95px" %)OK 732 +|(% style="width:160px" %)AT+ SETCNT =100|(% style="width:221px" %)Set the count number to 100.|(% style="width:95px" %)OK 670 670 671 - ==7.3 Why doeshesensorreadingshow0or "No sensor" ==734 +(% style="color:blue" %)**Downlink Command:** 672 672 736 +* **Example**: 0xA6000001 ~/~/ Same as AT+ SETCNT =1 673 673 674 - ~1.The measurementobjectisveryclosetothesensor,but in the blindspotofthesensor.738 +* **Example**: 0xA6000064 ~/~/ Same as AT+ SETCNT =100 675 675 676 - 2. Sensorwiringis disconnected740 +=== 3.3.8 Set Interrupt Mode === 677 677 678 -3. Not using the correct decoder 679 679 743 +Feature, Set Interrupt mode for PA8 of pin. 680 680 681 - ==7.4AbnormalreadingsThegap betweenmultiplereadingsistoo largeor the gapbetween the readings andtheactualvalueistoolarge ==745 +When AT+INTMOD=0 is set, PA8 is used as a digital input port. 682 682 747 +(% style="color:blue" %)**AT Command: AT+INTMOD** 683 683 684 -1) Please check if there is something on the probe affecting its measurement (condensed water, volatile oil, etc.) 749 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %) 750 +|=(% style="width: 155px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 197px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 158px;background-color:#D9E2F3;color:#0070C0" %)**Response** 751 +|(% style="width:154px" %)AT+INTMOD=?|(% style="width:196px" %)Show current interrupt mode|(% style="width:157px" %)((( 752 +0 753 +OK 754 +the mode is 0 =Disable Interrupt 755 +))) 756 +|(% style="width:154px" %)AT+INTMOD=2|(% style="width:196px" %)((( 757 +Set Transmit Interval 758 +0. (Disable Interrupt), 759 +~1. (Trigger by rising and falling edge) 760 +2. (Trigger by falling edge) 761 +3. (Trigger by rising edge) 762 +)))|(% style="width:157px" %)OK 685 685 686 - 2)Doesitchangewith temperature,temperaturewill affectitsmeasurement764 +(% style="color:blue" %)**Downlink Command: 0x06** 687 687 688 - 3) If abnormal dataoccurs, you canturnon DEBUG mode,Pleaseuse downlinkorATCOMMANtoenter DEBUG mode.766 +Format: Command Code (0x06) followed by 3 bytes. 689 689 690 - downlinkcommand:(%style="color:blue"%)**F101**(%%),AT command:(%style="color:blue"%)**AT+DDEBUG=1**768 +This means that the interrupt mode of the end node is set to 0x000003=3 (rising edge trigger), and the type code is 06. 691 691 692 - 4)After entering the debugmode,itwill send20piecesofdataatatime,andyoucan senditsuplinktous for analysis770 +* Example 1: Downlink Payload: 06000000 ~/~/ Turn off interrupt mode 693 693 694 - [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDDS75%20-%20LoRaWAN%20Distance%20Detection%20Sensor%20User%20Manual/WebHome/image-20230113135125-2.png?width=1057&height=136&rev=1.1||alt="image-20230113135125-2.png"]]772 +* Example 2: Downlink Payload: 06000003 ~/~/ Set the interrupt mode to rising edge trigger 695 695 774 +=== 3.3.9 Set work mode === 696 696 697 -Its original payload will be longer than other data. Even though it is being parsed, it can be seen that it is abnormal data. 698 698 699 - Please sendthedata tous forcheck.777 +Feature: Manually set the work mode 700 700 701 701 702 - =8. OrderInfo=780 +(% style="color:blue" %)**AT Command: AT+MOD** 703 703 782 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:463px" %) 783 +|=(% style="width: 162px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 193px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 108px;background-color:#D9E2F3;color:#0070C0" %)**Response** 784 +|(% style="width:162px" %)AT+MOD=0|(% style="width:191px" %)Set the work mode to 0.|(% style="width:106px" %)OK 785 +|(% style="width:162px" %)AT+MOD=1|(% style="width:191px" %)Set the work mode to 1|(% style="width:106px" %)OK 704 704 705 - Part Number:(% style="color:blue" %)**DDS75-LB-XXX**787 +(% style="color:blue" %)**Downlink Command:** 706 706 707 - (%style="color:red"%)**XXX**(%%):**Thedefaultfrequencyband**789 +* **Example: **0x0A00 ~/~/ Same as AT+MOD=0 708 708 791 +* **Example:** 0x0A01 ~/~/ Same as AT+MOD=1 792 + 793 += 4. Battery & Power Consumption = 794 + 795 + 796 +SW3L-LB use ER26500 + SPC1520 battery pack. See below link for detail information about the battery info and how to replace. 797 + 798 +[[**Battery Info & Power Consumption Analyze**>>http://wiki.dragino.com/xwiki/bin/view/Main/How%20to%20calculate%20the%20battery%20life%20of%20Dragino%20sensors%3F/]] . 799 + 800 + 801 += 5. OTA Firmware update = 802 + 803 + 804 +(% class="wikigeneratedid" %) 805 +User can change firmware SW3L-LB to: 806 + 807 +* Change Frequency band/ region. 808 + 809 +* Update with new features. 810 + 811 +* Fix bugs. 812 + 813 +Firmware and changelog can be downloaded from : **[[Firmware download link>>url:https://www.dropbox.com/sh/kwqv57tp6pejias/AAAopYMATh1GM6fZ-VRCLrpDa?dl=0]]** 814 + 815 +Methods to Update Firmware: 816 + 817 +* (Recommanded way) OTA firmware update via wireless: [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/Firmware%20OTA%20Update%20for%20Sensors/>>url:http://wiki.dragino.com/xwiki/bin/view/Main/Firmware%20OTA%20Update%20for%20Sensors/]] 818 + 819 +* Update through UART TTL interface. **[[Instruction>>url:http://wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H1.LoRaSTv4baseHardware]]**. 820 + 821 += 6. FAQ = 822 + 823 +== 6.1 AT Commands input doesn't work == 824 + 825 + 826 +In the case if user can see the console output but can't type input to the device. Please check if you already include the (% style="color:green" %)**ENTER**(%%) while sending out the command. Some serial tool doesn't send (% style="color:green" %)**ENTER**(%%) while press the send key, user need to add ENTER in their string. 827 + 828 + 829 += 7. Order Info = 830 + 831 + 832 +Part Number: (% style="color:blue" %)**SW3L-LB-XXX-YYY** 833 + 834 +(% style="color:red" %)**XXX**(%%): The default frequency band 835 + 709 709 * (% style="color:red" %)**AS923**(%%): LoRaWAN AS923 band 710 710 711 711 * (% style="color:red" %)**AU915**(%%): LoRaWAN AU915 band ... ... @@ -722,13 +722,43 @@ 722 722 723 723 * (% style="color:red" %)**CN470**(%%): LoRaWAN CN470 band 724 724 852 +((( 853 +(% style="color:blue" %)**YYY**(%%): Flow Sensor Model: 854 +))) 725 725 726 -= 9. Packing Info = 856 +((( 857 + **004:** DW-004 Flow Sensor: diameter: G1/2” / DN15. 450 pulse = 1 L 858 +))) 727 727 860 +((( 861 + **006:** DW-006 Flow Sensor: diameter: G3/4” / DN20. 390 pulse = 1 L 862 +))) 728 728 864 +((( 865 + **010:** DW-010 Flow Sensor: diameter: G 1” / DN25. 64 pulse = 1 L 866 +))) 867 + 868 +* ((( 869 +calculate flag=0: for SW3L-004 Flow Sensor: 450 pulse = 1 L 870 +))) 871 + 872 +* ((( 873 +calculate flag=1: for SW3L-006 Flow Sensor: 390 pulse = 1 L 874 +))) 875 + 876 +* ((( 877 +calculate flag=2: for SW3L-010 Flow Sensor: 64 pulse = 1 L 878 + 879 + 880 + 881 +))) 882 + 883 += 8. Packing Info = 884 + 885 + 729 729 (% style="color:#037691" %)**Package Includes**: 730 730 731 -* DDS75-LB LoRaWANDistance DetectionSensorx 1888 +* SW3L-LB LoRaWAN Flow Sensor 732 732 733 733 (% style="color:#037691" %)**Dimension and weight**: 734 734 ... ... @@ -740,10 +740,9 @@ 740 740 741 741 * Weight / pcs : g 742 742 900 += 9. Support = 743 743 744 -= 10. Support = 745 745 746 - 747 747 * Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule. 748 748 749 749 * Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[Support@dragino.cc>>mailto:Support@dragino.cc]].