Last modified by Mengting Qiu on 2023/12/14 11:15

From version 70.19
edited by Xiaoling
on 2023/06/13 09:00
Change comment: There is no comment for this version
To version 70.4
edited by Xiaoling
on 2023/06/12 17:15
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -22,13 +22,13 @@
22 22  
23 23  It detects the distance(% style="color:blue" %)**  between the measured object and the sensor**(%%), and uploads the value via wireless to LoRaWAN IoT Server.
24 24  
25 -The LoRa wireless technology used in DDS75-LB allows device to send data and reach extremely long ranges at low data-rates. It provides ultra-long range spread spectrum communication and high interference immunity whilst minimizing current consumption.
25 +The LoRa wireless technology used in SW3L-LB allows device to send data and reach extremely long ranges at low data-rates. It provides ultra-long range spread spectrum communication and high interference immunity whilst minimizing current consumption.
26 26  
27 -DDS75-LB (% style="color:blue" %)**supports BLE configure**(%%) and (% style="color:blue" %)**wireless OTA update**(%%) which make user easy to use.
27 +SW3L-LB (% style="color:blue" %)**supports BLE configure**(%%) and (% style="color:blue" %)**wireless OTA update**(%%) which make user easy to use.
28 28  
29 -DDS75-LB is powered by (% style="color:blue" %)**8500mAh Li-SOCI2 battery**(%%), it is designed for long term use up to 5 years.
29 +SW3L-LB is powered by (% style="color:blue" %)**8500mAh Li-SOCI2 battery**(%%), it is designed for long term use up to 5 years.
30 30  
31 -Each DDS75-LB is pre-load with a set of unique keys for LoRaWAN registrations, register these keys to local LoRaWAN server and it will auto connect after power on.
31 +Each SW3L-LB is pre-load with a set of unique keys for LoRaWAN registrations, register these keys to local LoRaWAN server and it will auto connect after power on.
32 32  
33 33  [[image:image-20230612170943-2.png||height="525" width="912"]]
34 34  
... ... @@ -39,47 +39,20 @@
39 39  * LoRaWAN 1.0.3 Class A
40 40  * Bands: CN470/EU433/KR920/US915/EU868/AS923/AU915/IN865
41 41  * Ultra-low power consumption
42 -* Distance Detection by Ultrasonic technology
43 -* Flat object range 280mm - 7500mm
44 -* Accuracy: ±(1cm+S*0.3%) (S: Distance)
45 -* Cable Length : 25cm
42 +* Upload water flow volume
43 +* Monitor water waste
44 +* AT Commands to change parameters
45 +* supports Datalog feature
46 46  * Support Bluetooth v5.1 and LoRaWAN remote configure
47 47  * Support wireless OTA update firmware
48 -* AT Commands to change parameters
48 +* Uplink on periodically and open/close event
49 49  * Downlink to change configure
50 -* IP66 Waterproof Enclosure
51 51  * 8500mAh Battery for long term use
52 52  
52 +
53 53  == 1.3 Specification ==
54 54  
55 55  
56 -(% style="color:#037691" %)**Rated environmental conditions:**
57 -
58 -(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:500px" %)
59 -|(% style="background-color:#d9e2f3; color:#0070c0; width:163px" %)**Item**|(% style="background-color:#d9e2f3; color:#0070c0; width:90px" %)(((
60 -**Minimum value**
61 -)))|(% style="background-color:#d9e2f3; color:#0070c0; width:70px" %)(((
62 -**Typical value**
63 -)))|(% style="background-color:#d9e2f3; color:#0070c0; width:87px" %)(((
64 -**Maximum value**
65 -)))|(% style="background-color:#d9e2f3; color:#0070c0; width:40px" %)**Unit**|(% style="background-color:#d9e2f3; color:#0070c0; width:50px" %)**Remarks**
66 -|(% style="width:174px" %)Storage temperature|(% style="width:86px" %)-25|(% style="width:66px" %)25|(% style="width:90px" %)80|(% style="width:48px" %)℃|(% style="width:203px" %)
67 -|(% style="width:174px" %)Storage humidity|(% style="width:86px" %) |(% style="width:66px" %)65%|(% style="width:90px" %)90%|(% style="width:48px" %)RH|(% style="width:203px" %)(1)
68 -|(% style="width:174px" %)Operating temperature|(% style="width:86px" %)-15|(% style="width:66px" %)25|(% style="width:90px" %)60|(% style="width:48px" %)℃|(% style="width:203px" %)
69 -|(% style="width:174px" %)Working humidity|(% style="width:86px" %)(((
70 -
71 -
72 -
73 -)))|(% style="width:66px" %)65%|(% style="width:90px" %)80%|(% style="width:48px" %)RH|(% style="width:203px" %)(1)
74 -
75 -(((
76 -**Remarks: (1) a. When the ambient temperature is 0-39 ℃, the maximum humidity is 90% (non-condensing);       **
77 -
78 -**~ b. When the ambient temperature is 40-50 ℃, the highest humidity is the highest humidity in the natural world at the current temperature (no condensation)**
79 -
80 -
81 -)))
82 -
83 83  (% style="color:#037691" %)**Common DC Characteristics:**
84 84  
85 85  * Supply Voltage: built in 8500mAh Li-SOCI2 battery , 2.5v ~~ 3.6v
... ... @@ -105,41 +105,25 @@
105 105  * Sleep Mode: 5uA @ 3.3v
106 106  * LoRa Transmit Mode: 125mA @ 20dBm, 82mA @ 14dBm
107 107  
108 -== 1.4 Effective measurement range Reference beam pattern ==
109 109  
82 +== 1.4 Applications ==
110 110  
111 -(% style="color:blue" %)**1. The tested object is a white cylindrical tube made of PVC, with a height of 100cm and a diameter of 7.5cm.**
112 112  
113 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDDS75%20-%20LoRaWAN%20Distance%20Detection%20Sensor%20User%20Manual/WebHome/1654852253176-749.png?rev=1.1||alt="1654852253176-749.png"]]
85 +* Flow Sensor application
86 +* Water Control
87 +* Toilet Flow Sensor
88 +* Monitor Waste water
114 114  
115 115  
116 -(% style="color:blue" %)**2. The object to be tested is a "corrugated cardboard box" perpendicular to the central axis of 0 °, and the length * width is 60cm * 50cm.**
91 +== 1.5 Sleep mode and working mode ==
117 117  
118 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDDS75%20-%20LoRaWAN%20Distance%20Detection%20Sensor%20User%20Manual/WebHome/1654852175653-550.png?rev=1.1||alt="1654852175653-550.png"]]
119 119  
120 -
121 -== 1.5 Applications ==
122 -
123 -
124 -* Horizontal distance measurement
125 -* Liquid level measurement
126 -* Parking management system
127 -* Object proximity and presence detection
128 -* Intelligent trash can management system
129 -* Robot obstacle avoidance
130 -* Automatic control
131 -* Sewer
132 -* Bottom water level monitoring
133 -
134 -== 1.6 Sleep mode and working mode ==
135 -
136 -
137 137  (% style="color:blue" %)**Deep Sleep Mode: **(%%)Sensor doesn't have any LoRaWAN activate. This mode is used for storage and shipping to save battery life.
138 138  
139 139  (% style="color:blue" %)**Working Mode:** (%%)In this mode, Sensor will work as LoRaWAN Sensor to Join LoRaWAN network and send out sensor data to server. Between each sampling/tx/rx periodically, sensor will be in IDLE mode), in IDLE mode, sensor has the same power consumption as Deep Sleep mode.
140 140  
141 141  
142 -== 1.7 Button & LEDs ==
99 +== 1.6 Button & LEDs ==
143 143  
144 144  
145 145  [[image:Main.User Manual for LoRaWAN End Nodes.D20-LBD22-LBD23-LB_LoRaWAN_Temperature_Sensor_User_Manual.WebHome@1675071855856-879.png]]
... ... @@ -158,12 +158,13 @@
158 158  )))
159 159  |(% style="width:167px" %)Fast press ACT 5 times.|(% style="width:117px" %)Deactivate Device|(% style="width:225px" %)(% style="color:red" %)**Red led**(%%) will solid on for 5 seconds. Means device is in Deep Sleep Mode.
160 160  
161 -== 1.8 BLE connection ==
162 162  
119 +== 1.7 BLE connection ==
163 163  
164 -DDS75-LB support BLE remote configure.
165 165  
122 +SW3L-LB support BLE remote configure.
166 166  
124 +
167 167  BLE can be used to configure the parameter of sensor or see the console output from sensor. BLE will be only activate on below case:
168 168  
169 169  * Press button to send an uplink
... ... @@ -173,13 +173,24 @@
173 173  If there is no activity connection on BLE in 60 seconds, sensor will shut down BLE module to enter low power mode.
174 174  
175 175  
176 -== 1.9 Pin Definitions ==
134 +== 1.8 Pin Definitions ==
177 177  
178 178  [[image:image-20230523174230-1.png]]
179 179  
180 180  
139 +== 1.9 Flow Sensor Spec ==
181 181  
182 182  
142 +(((
143 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:510px" %)
144 +|=(% style="width: 80px;background-color:#D9E2F3;color:#0070C0" %)**Model**|=(% style="width: 80px;background-color:#D9E2F3;color:#0070C0" %)**Probe**|=(% style="width: 80px;background-color:#D9E2F3;color:#0070C0" %)**Diameter**|=(% style="width: 80px;background-color:#D9E2F3;color:#0070C0" %)**Range**|=(% style="width: 80px;background-color:#D9E2F3;color:#0070C0" %)**Max Pressure**|=(% style="width: 110px;background-color:#D9E2F3;color:#0070C0" %)**Measure**
145 +|(% style="width:88px" %)SW3L-004|(% style="width:75px" %)DW-004|(% style="width:107px" %)G1/2" /DN15|(% style="width:101px" %)1~~30L/min|(% style="width:116px" %)≤ 2.0Mpa|(% style="width:124px" %)450 pulse = 1 L
146 +|(% style="width:88px" %)SW3L-006|(% style="width:75px" %)DW-006|(% style="width:107px" %)G3/4" /DN20|(% style="width:101px" %)1~~60L/min|(% style="width:116px" %)≤ 1.2Mpa|(% style="width:124px" %)390 pulse = 1 L
147 +|(% style="width:88px" %)SW3L-010|(% style="width:75px" %)DW-010|(% style="width:107px" %)G 1" /DN25|(% style="width:101px" %)2~~100L/min|(% style="width:116px" %)≤ 2.0Mpa|(% style="width:124px" %)64 pulse = 1 L
148 +)))
149 +
150 +
151 +
183 183  == 2.10 Mechanical ==
184 184  
185 185  
... ... @@ -192,24 +192,27 @@
192 192  [[image:Main.User Manual for LoRaWAN End Nodes.D20-LBD22-LBD23-LB_LoRaWAN_Temperature_Sensor_User_Manual.WebHome@1675143909447-639.png]]
193 193  
194 194  
195 -**Probe Mechanical:**
164 +(% style="color:blue" %)**DW-004 Flow Sensor: diameter: G1/2” / DN15.  450 pulse = 1 L**
196 196  
166 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/SW3L%20LoRaWAN%20Outdoor%20Flow%20Sensor/WebHome/image-20220519091350-1.png?width=722&height=385&rev=1.1||alt="image-20220519091350-1.png"]]
197 197  
198 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDDS75%20-%20LoRaWAN%20Distance%20Detection%20Sensor%20User%20Manual/WebHome/image-20220610172003-1.png?rev=1.1||alt="image-20220610172003-1.png"]]
199 199  
169 +(% style="color:blue" %)**006: DW-006 Flow Sensor: diameter: G3/4” / DN20.  390 pulse = 1 L**
200 200  
201 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDDS75%20-%20LoRaWAN%20Distance%20Detection%20Sensor%20User%20Manual/WebHome/image-20220610172003-2.png?rev=1.1||alt="image-20220610172003-2.png"]]
171 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/SW3L%20LoRaWAN%20Outdoor%20Flow%20Sensor/WebHome/image-20220519091423-2.png?width=723&height=258&rev=1.1||alt="image-20220519091423-2.png"]]
202 202  
203 203  
204 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDDS75%20-%20LoRaWAN%20Distance%20Detection%20Sensor%20User%20Manual/WebHome/image-20220610172003-2.png?rev=1.1||alt="image-20220610172003-2.png"]]
174 +(% style="color:blue" %)**010: DW-010 Flow Sensor: diameter: G 1” / DN25. 64 pulse = 1 L**
205 205  
176 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/SW3L%20LoRaWAN%20Outdoor%20Flow%20Sensor/WebHome/image-20220519091423-3.png?width=724&height=448&rev=1.1||alt="image-20220519091423-3.png"]]
206 206  
207 -= 2. Configure DDS75-LB to connect to LoRaWAN network =
208 208  
179 += 2. Configure SW3L-LB to connect to LoRaWAN network =
180 +
209 209  == 2.1 How it works ==
210 210  
211 211  
212 -The DDS75-LB is configured as (% style="color:#037691" %)**LoRaWAN OTAA Class A**(%%) mode by default. It has OTAA keys to join LoRaWAN network. To connect a local LoRaWAN network, you need to input the OTAA keys in the LoRaWAN IoT server and press the button to activate the DDS75-LB. It will automatically join the network via OTAA and start to send the sensor value. The default uplink interval is 20 minutes.
184 +The SW3L-LB is configured as (% style="color:#037691" %)**LoRaWAN OTAA Class A**(%%) mode by default. It has OTAA keys to join LoRaWAN network. To connect a local LoRaWAN network, you need to input the OTAA keys in the LoRaWAN IoT server and press the button to activate the SW3L-LB. It will automatically join the network via OTAA and start to send the sensor value. The default uplink interval is 20 minutes.
213 213  
214 214  (% style="display:none" %) (%%)
215 215  
... ... @@ -223,9 +223,9 @@
223 223  [[image:image-20230612171032-3.png||height="492" width="855"]](% style="display:none" %)
224 224  
225 225  
226 -(% style="color:blue" %)**Step 1:**(%%) Create a device in TTN with the OTAA keys from DDS75-LB.
198 +(% style="color:blue" %)**Step 1:**(%%) Create a device in TTN with the OTAA keys from SW3L-LB.
227 227  
228 -Each DDS75-LB is shipped with a sticker with the default device EUI as below:
200 +Each SW3L-LB is shipped with a sticker with the default device EUI as below:
229 229  
230 230  [[image:image-20230426084152-1.png||alt="图片-20230426084152-1.png" height="233" width="502"]]
231 231  
... ... @@ -254,10 +254,10 @@
254 254  [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LSN50v2-S31-S31B%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20User%20Manual/WebHome/image-20220611161308-6.png?width=744&height=485&rev=1.1||alt="图片-20220611161308-6.png"]]
255 255  
256 256  
257 -(% style="color:blue" %)**Step 2:**(%%) Activate on DDS75-LB
229 +(% style="color:blue" %)**Step 2:**(%%) Activate on SW3L-LB
258 258  
259 259  
260 -Press the button for 5 seconds to activate the DDS75-LB.
232 +Press the button for 5 seconds to activate the SW3L-LB.
261 261  
262 262  (% style="color:green" %)**Green led**(%%) will fast blink 5 times, device will enter (% style="color:blue" %)**OTA mode**(%%) for 3 seconds. And then start to JOIN LoRaWAN network. (% style="color:green" %)**Green led**(%%) will solidly turn on for 5 seconds after joined in network.
263 263  
... ... @@ -264,175 +264,355 @@
264 264  After join success, it will start to upload messages to TTN and you can see the messages in the panel.
265 265  
266 266  
267 -== 2.3  ​Uplink Payload ==
239 +== 2.3 ​Uplink Payload ==
268 268  
241 +=== 2.3.1 Device Status, FPORT~=5 ===
269 269  
270 -(((
271 -DDS75-LB will uplink payload via LoRaWAN with below payload format: 
272 -)))
273 273  
274 -(((
275 -Uplink payload includes in total 4 bytes.
276 -Payload for firmware version v1.1.4. . Before v1.1.3, there is on two fields: BAT and Distance
277 -)))
244 +Include device configure status. Once SW3L-LB Joined the network, it will uplink this message to the server. After that, SW3L-LB will uplink Device Status every 12 hours.
278 278  
246 +Users can use the downlink command(**0x26 01**) to ask SW3L-LB to send device configure detail, include device configure status. SW3L-LB will uplink a payload via FPort=5 to server.
279 279  
248 +The Payload format is as below.
280 280  
281 -(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:510px" %)
282 -|=(% style="width: 62.5px;background-color:#D9E2F3;color:#0070C0" %)(((
283 -**Size(bytes)**
284 -)))|=(% style="width: 62.5px;background-color:#D9E2F3;color:#0070C0" %)**2**|=(% style="background-color:#D9E2F3;color:#0070C0" %)**2**|=(% style="background-color:#D9E2F3;color:#0070C0" %)1|=(% style="background-color:#D9E2F3;color:#0070C0" %)2|=(% style="background-color:#D9E2F3;color:#0070C0" %)**1**
285 -|(% style="width:62.5px" %)**Value**|(% style="width:62.5px" %)[[BAT>>||anchor="H2.3.1A0BatteryInfo"]]|(((
286 -[[Distance>>||anchor="H2.3.2A0Distance"]]
287 -(unit: mm)
288 -)))|[[Digital Interrupt (Optional)>>||anchor="H2.3.3A0InterruptPin"]]|(((
289 -[[Temperature (Optional )>>||anchor="H2.3.4A0DS18B20Temperaturesensor"]]
290 -)))|[[Sensor Flag>>||anchor="H2.3.5A0SensorFlag"]]
291 291  
292 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDDS75%20-%20LoRaWAN%20Distance%20Detection%20Sensor%20User%20Manual/WebHome/1654850511545-399.png?rev=1.1||alt="1654850511545-399.png"]]
251 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %)
252 +|(% colspan="6" style="background-color:#d9e2f3; color:#0070c0" %)**Device Status (FPORT=5)**
253 +|(% style="width:103px" %)**Size (bytes)**|(% style="width:72px" %)**1**|**2**|(% style="width:91px" %)**1**|(% style="width:86px" %)**1**|(% style="width:44px" %)**2**
254 +|(% style="width:103px" %)**Value**|(% style="width:72px" %)Sensor Model|Firmware Version|(% style="width:91px" %)Frequency Band|(% style="width:86px" %)Sub-band|(% style="width:44px" %)BAT
293 293  
256 +Example parse in TTNv3
294 294  
295 -=== 2.3.1  Battery Info ===
258 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/SW3L%20LoRaWAN%20Outdoor%20Flow%20Sensor/WebHome/1652925144491-755.png?width=732&height=139&rev=1.1||alt="1652925144491-755.png"]]
296 296  
297 297  
298 -Check the battery voltage for DDS75-LB.
261 +(% style="color:#037691" %)**Sensor Model**(%%): For SW3L-LB, this value is 0x11
299 299  
263 +(% style="color:#037691" %)**Firmware Version**(%%): 0x0100, Means: v1.0.0 version
264 +
265 +(% style="color:#037691" %)**Frequency Band**:
266 +
267 +*0x01: EU868
268 +
269 +*0x02: US915
270 +
271 +*0x03: IN865
272 +
273 +*0x04: AU915
274 +
275 +*0x05: KZ865
276 +
277 +*0x06: RU864
278 +
279 +*0x07: AS923
280 +
281 +*0x08: AS923-1
282 +
283 +*0x09: AS923-2
284 +
285 +*0x0a: AS923-3
286 +
287 +*0x0b: CN470
288 +
289 +*0x0c: EU433
290 +
291 +*0x0d: KR920
292 +
293 +*0x0e: MA869
294 +
295 +
296 +(% style="color:#037691" %)**Sub-Band**:
297 +
298 +AU915 and US915:value 0x00 ~~ 0x08
299 +
300 +CN470: value 0x0B ~~ 0x0C
301 +
302 +Other Bands: Always 0x00
303 +
304 +
305 +(% style="color:#037691" %)**Battery Info**:
306 +
307 +Check the battery voltage.
308 +
300 300  Ex1: 0x0B45 = 2885mV
301 301  
302 302  Ex2: 0x0B49 = 2889mV
303 303  
304 304  
305 -=== 2.3.2  Distance ===
314 +=== 2.3.2 Sensor Configuration, FPORT~=4 ===
306 306  
307 307  
317 +SW3L-LB will only send this command after getting the downlink command (0x26 02) from the server.
318 +
319 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:510px" %)
320 +|(% style="background-color:#d9e2f3; color:#0070c0; width:70px" %) **Size(bytes)**|(% style="background-color:#d9e2f3; color:#0070c0; width:105px" %)**3**|(% style="background-color:#d9e2f3; color:#0070c0; width:60px" %)**1**|(% style="background-color:#d9e2f3; color:#0070c0; width:96px" %)**1**|(% style="background-color:#d9e2f3; color:#0070c0; width:105px" %)**2**|(% style="background-color:#d9e2f3; color:#0070c0; width:74px" %)**1**
321 +|**Value**|(% style="width:104px" %)TDC(unit:sec)|(% style="width:43px" %)N/A|(% style="width:91px" %)Stop Timer|(% style="width:100px" %)Alarm Timer|(% style="width:69px" %)Reserve
322 +
323 +* (% style="color:#037691" %)**TDC: (default: 0x0004B0)**
324 +
325 +Uplink interval for the total pulse count, default value is 0x0004B0 which is 1200 seconds = 20 minutes.
326 +
327 +
328 +* (% style="color:#037691" %)**STOP Duration & Alarm Timer**
329 +
330 +Shows the configure value of [[Alarm for continuously water flow>>||anchor="H3.3.4Alarmforcontinuouslywaterflow"]]
331 +
332 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/SW3L%20LoRaWAN%20Outdoor%20Flow%20Sensor/WebHome/image-20220519095747-2.png?width=723&height=113&rev=1.1||alt="image-20220519095747-2.png"]]
333 +
334 +
335 +=== 2.3.3 Water Flow Value, Uplink FPORT~=2 ===
336 +
337 +
308 308  (((
309 -Get the distance. Flat object range 280mm - 7500mm.
339 +SW3L-LB will send this uplink **after** Device Status once join the LoRaWAN network successfully. And SW3L-LB will:
310 310  )))
311 311  
312 312  (((
313 -For example, if the data you get from the register is 0x0B 0x05, the distance between the sensor and the measured object is(% style="color:#4472c4" %)** **
343 +periodically send this uplink every 20 minutes, this interval [[can be changed>>||anchor="H3.3.1SetTransmitIntervalTime"]].
344 +)))
314 314  
315 -(% style="color:#4472c4" %)**0B05(H) = 2821 (D) = 2821 mm.**
346 +(((
347 +Uplink Payload totals 11 bytes.
316 316  )))
317 317  
350 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:510px" %)
351 +|=(% colspan="6" style="width: 510px;background-color:#D9E2F3;color:#0070C0" %)**Water Flow Value,  FPORT=2**
352 +|(% style="width:60px" %)**Size(bytes)**|(% style="width:130px" %)**1**|(% style="width:130px" %)**4**|(% style="width:30px" %)**1**|(% style="width:50px" %)**1**|(% style="width:80px" %)**4**
353 +|(% style="width:110px" %)**Value**|(% style="width:81px" %)Calculate Flag & [[Alarm>>||anchor="H3.3.4Alarmforcontinuouslywaterflow"]]|(% style="width:95px" %)(((
354 +Total pulse Or Last Pulse
355 +)))|(% style="width:55px" %)MOD|(% style="width:115px" %)Reserve(0x01)|(% style="width:129px" %)[[Unix TimeStamp>>||anchor="H2.5.2UnixTimeStamp"]]
318 318  
319 -* If the sensor value is 0x0000, it means system doesn't detect ultrasonic sensor.
320 -* If the sensor value lower than 0x0118 (280mm), the sensor value will be invalid. Since v1.1.4, all value lower than 280mm will be set to 0x0014(20mm) which means the value is invalid.
357 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:470px" %)
358 +|=(% colspan="4" style="width: 470px;background-color:#D9E2F3;color:#0070C0" %)**Status & Alarm field**
359 +|(% style="width:60px" %)**Size(bit)**|(% style="width:80px" %)**6**|(% style="width:310px" %)**1**|(% style="width:20px" %)**1**
360 +|(% style="width:88px" %)**Value**|(% style="width:117px" %)Calculate Flag|(% style="width:221px" %)Alarm: 0: No Alarm; 1: Alarm|(% style="width:64px" %)N/A
321 321  
362 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/SW3L%20LoRaWAN%20Outdoor%20Flow%20Sensor/WebHome/image-20220519095946-3.png?width=736&height=284&rev=1.1||alt="image-20220519095946-3.png"]]
322 322  
323 -=== 2.3.3  Interrupt Pin ===
324 324  
365 +* (((
366 +(% style="color:#037691" %)**Calculate Flag**
367 +)))
325 325  
326 -This data field shows if this packet is generated by interrupt or not. [[Click here>>||anchor="H3.3A0SetInterruptMode"]] for the hardware and software set up.
369 +(((
370 +The calculate flag is a user defined field, IoT server can use this flag to handle different meters with different pulse factors. For example, if there are 100 Flow Sensors, meters 1 ~~50 are 1 liter/pulse and meters 51 ~~ 100 has 1.5 liter/pulse.
371 +)))
327 327  
328 -**Example:**
373 +(((
374 +**Example: in the default payload:**
375 +)))
329 329  
330 -0x00: Normal uplink packet.
377 +* (((
378 +calculate flag=0: for SW3L-004 Flow Sensor: 450 pulse = 1 L
379 +)))
380 +* (((
381 +calculate flag=1: for SW3L-006 Flow Sensor: 390 pulse = 1 L
382 +)))
383 +* (((
384 +calculate flag=2: for SW3L-010 Flow Sensor: 64 pulse = 1 L
385 +)))
331 331  
332 -0x01: Interrupt Uplink Packet.
387 +(((
388 +Default value: 0. 
389 +)))
333 333  
391 +(((
392 +Range (6 bits): (b)000000 ~~ (b) 111111
334 334  
335 -=== 2.3.4  DS18B20 Temperature sensor ===
394 +If user use with a meter for example is 0.02L/pulse. To proper decode the correct value in server,
336 336  
396 +1) User can set the Calculate Flag of this sensor to 3.
337 337  
338 -This is optional, user can connect external DS18B20 sensor to the +3.3v, 1-wire and GND pin . and this field will report temperature.
398 +2) In server side, when a sensor data arrive, the decoder will check the value of Calculate Flag, It the value is 3, the total volume = 0.02 x Pulse Count.
399 +)))
339 339  
340 -**Example**:
401 +(((
402 +(% style="color:red" %)**NOTE: User need to set Calculate Flag to proper value before use Flow Sensor. Downlink or AT Command see: **(%%)Refer: [[Set Calculate Flag>>||anchor="H3.3.6Setthecalculateflag"]]
403 +)))
341 341  
342 -If payload is: 0105H:  (0105 & FC00 == 0), temp = 0105H /10 = 26.1 degree
405 +* (((
406 +(% style="color:#037691" %)**Alarm**
407 +)))
343 343  
344 -If payload is: FF3FH :  (FF3F & FC00 == 1) , temp = (FF3FH - 65536)/10 = -19.3 degrees.
409 +(((
410 +See [[Alarm for continuously water flow>>||anchor="H3.3.4Alarmforcontinuouslywaterflow"]]
411 +)))
345 345  
346 -(% style="color:red" %)**Note: DS18B20 feature is supported in the hardware version > v1.3 which made since early of 2021.**
413 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/SW3L%20LoRaWAN%20Outdoor%20Flow%20Sensor/WebHome/image-20220519095946-4.png?width=724&height=65&rev=1.1||alt="image-20220519095946-4.png"]]
347 347  
348 348  
349 -=== 2.3.5  Sensor Flag ===
416 +* (((
417 +(% style="color:#037691" %)**Total pulse**
418 +)))
350 350  
420 +(((
421 +Total pulse/counting since factory
422 +)))
351 351  
352 352  (((
353 -0x01: Detect Ultrasonic Sensor
425 +Range (4 Bytes) : 0x00000000~~ 0xFFFFFFFF .
354 354  )))
355 355  
428 +* (((
429 +(% style="color:#037691" %)**Last Pulse**
430 +)))
431 +
356 356  (((
357 -0x00: No Ultrasonic Sensor
433 +Total pulse since last FPORT=2 uplink. (Default 20 minutes)
358 358  )))
359 359  
436 +(((
437 +Range (4 Bytes) : 0x00000000~~ 0xFFFFFFFF .
438 +)))
360 360  
361 -=== 2.3.6  Decode payload in The Things Network ===
440 +* (((
441 +(% style="color:#037691" %)**MOD: Default =0**
442 +)))
362 362  
444 +(((
445 +MOD=0 ~-~-> Uplink Total Pulse since factory
446 +)))
363 363  
364 -While using TTN network, you can add the payload format to decode the payload.
448 +(((
449 +MOD=1 ~-~-> Uplink total pulse since last FPORT=2 uplink.
450 +)))
365 365  
366 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDDS75%20-%20LoRaWAN%20Distance%20Detection%20Sensor%20User%20Manual/WebHome/1654850829385-439.png?rev=1.1||alt="1654850829385-439.png"]]
452 +* (((
453 +(% style="color:#037691" %)**Water Flow Value**
454 +)))
367 367  
368 -The payload decoder function for TTN V3 is here:
456 +(((
457 +**Total Water Flow Volume = (Calculate Flag) x (Total Pulse)=9597/450=21.3L**
458 +)))
369 369  
460 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/SW3L%20LoRaWAN%20Outdoor%20Flow%20Sensor/WebHome/image-20220519095946-5.png?width=727&height=50&rev=1.1||alt="image-20220519095946-5.png"]]
461 +
462 +
370 370  (((
371 -DDS75-LB TTN V3 Payload Decoder:  [[ttps:~~/~~/github.com/dragino/dragino-end-node-decoder>>https://github.com/dragino/dragino-end-node-decoder]]
464 +**Total Water Flow for TDC timer = (Calculate Flag) x (Last Pulse)=79/450=0.2L**
372 372  )))
373 373  
467 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/SW3L%20LoRaWAN%20Outdoor%20Flow%20Sensor/WebHome/image-20220519095946-6.png?width=733&height=43&rev=1.1||alt="image-20220519095946-6.png"]] ** **
374 374  
375 -== 2.4  Uplink Interval ==
376 376  
470 +=== 2.3.4 Historical Water Flow Status, FPORT~=3 ===
377 377  
378 -The DDS75-LB by default uplink the sensor data every 20 minutes. User can change this interval by AT Command or LoRaWAN Downlink Command. See this link: [[Change Uplink Interval>>doc:Main.End Device AT Commands and Downlink Command.WebHome||anchor="H4.1ChangeUplinkInterval"]]
379 379  
473 +(((
474 +SW3L-LB stores sensor values and users can retrieve these history values via the [[downlink command>>||anchor="H2.5DatalogFeature"]].
475 +)))
380 380  
381 -== 2.5  ​Show Data in DataCake IoT Server ==
477 +(((
478 +The historical payload includes one or multiplies entries and every entry has the same payload as Real-Time water flow status.
479 +)))
382 382  
481 +* (((
482 +Each data entry is 11 bytes and has the same structure as [[real time water flow status>>||anchor="H2.3.3A0WaterFlowValue2CUplinkFPORT3D2"]], to save airtime and battery, SW3L will send max bytes according to the current DR and Frequency bands.
483 +)))
383 383  
384 384  (((
385 -[[DATACAKE>>url:https://datacake.co/]] provides a human friendly interface to show the sensor data, once we have data in TTN, we can use [[DATACAKE>>url:https://datacake.co/]] to connect to TTN and see the data in DATACAKE. Below are the steps:
486 +For example, in the US915 band, the max payload for different DR is:
386 386  )))
387 387  
388 388  (((
389 -
490 +(% style="color:blue" %)**a) DR0:**(%%) max is 11 bytes so one entry of data
390 390  )))
391 391  
392 392  (((
393 -(% style="color:blue" %)**Step 1**(%%)**: Be sure that your device is programmed and properly connected to the network at this time.**
494 +(% style="color:blue" %)**b) DR1:**(%%) max is 53 bytes so devices will upload 4 entries of data (total 44 bytes)
394 394  )))
395 395  
396 396  (((
397 -(% style="color:blue" %)**Step 2**(%%)**: To configure the Application to forward data to DATACAKE you will need to add integration. To add the DATACAKE integration, perform the following steps:**
498 +(% style="color:blue" %)**c) DR2:**(%%) total payload includes 11 entries of data
398 398  )))
399 399  
501 +(((
502 +(% style="color:blue" %)**d) DR3:**(%%) total payload includes 22 entries of data.
503 +)))
400 400  
401 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDDS75%20-%20LoRaWAN%20Distance%20Detection%20Sensor%20User%20Manual/WebHome/1654592790040-760.png?rev=1.1||alt="1654592790040-760.png"]]
505 +(((
506 +If SW3L-LB doesn't have any data in the polling time. It will uplink 11 bytes of 0
507 +)))
402 402  
509 +(((
510 +(% style="color:#037691" %)**Downlink:**
511 +)))
403 403  
404 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDDS75%20-%20LoRaWAN%20Distance%20Detection%20Sensor%20User%20Manual/WebHome/1654592800389-571.png?rev=1.1||alt="1654592800389-571.png"]]
513 +(((
514 +0x31 62 46 B1 F0 62 46 B3 94 07
515 +)))
405 405  
517 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/SW3L%20LoRaWAN%20Outdoor%20Flow%20Sensor/WebHome/1652926690850-712.png?width=726&height=115&rev=1.1||alt="1652926690850-712.png"]]
406 406  
407 -(% style="color:blue" %)**Step 3**(%%)**: Create an account or log in Datacake.**
408 408  
409 -(% style="color:blue" %)**Step 4**(%%)**: Search the DDS75-LB and add DevEUI.**
520 +(((
521 +(% style="color:#037691" %)**Uplink:**
522 +)))
410 410  
411 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDDS75%20-%20LoRaWAN%20Distance%20Detection%20Sensor%20User%20Manual/WebHome/1654851029373-510.png?rev=1.1||alt="1654851029373-510.png"]]
524 +(((
525 +00 00 01 00 00 00 00 62 46 B2 26 00 00 01 00 00 00 00 62 46 B2 5D 00 00 01 00 00 00 00 62 46 B2 99 00 00 01 00 00 00 00 62 46 B2 D5 00 00 01 00 00 01 15 62 46 B3 11 00 00 01 00 00 01 1F 62 46 B3 7E
526 +)))
412 412  
528 +(((
529 +(% style="color:#037691" %)**Parsed Value:**
530 +)))
413 413  
414 -After added, the sensor data arrive TTN V3, it will also arrive and show in Datacake.
532 +(((
533 +[Alarm, Calculate Flag, MOD, Total pulse or Last Pulse,** **Water Flow Value, TIME]
534 +)))
415 415  
416 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDDS75%20-%20LoRaWAN%20Distance%20Detection%20Sensor%20User%20Manual/WebHome/image-20220610165129-11.png?width=1088&height=595&rev=1.1||alt="image-20220610165129-11.png"]]
417 417  
537 +(((
538 +[FALSE,0,0,0,0.0,2022-04-01 08:04:54],
539 +)))
418 418  
541 +(((
542 +[FALSE,0,0,0,0.0,2022-04-01 08:05:49],
543 +)))
419 419  
420 -== 2.6 Datalog Feature ==
545 +(((
546 +[FALSE,0,0,0,0.0,2022-04-01 08:06:49],
547 +)))
421 421  
549 +(((
550 +[FALSE,0,0,0,0.0,2022-04-01 08:07:49],
551 +)))
422 422  
423 -Datalog Feature is to ensure IoT Server can get all sampling data from Sensor even if the LoRaWAN network is down. For each sampling, DDS75-LB will store the reading for future retrieving purposes.
553 +(((
554 +[FALSE,0,0,277,0.6,2022-04-01 08:08:49],
555 +)))
424 424  
557 +(((
558 +[FALSE,0,0,287,0.6,2022-04-01 08:10:38],
559 +)))
425 425  
426 -=== 2.6.1 Ways to get datalog via LoRaWAN ===
561 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/SW3L%20LoRaWAN%20Outdoor%20Flow%20Sensor/WebHome/1652926777796-267.png?width=724&height=279&rev=1.1||alt="1652926777796-267.png"]]
427 427  
428 428  
429 -Set PNACKMD=1, DDS75-LB will wait for ACK for every uplink, when there is no LoRaWAN network,DDS75-LB will mark these records with non-ack messages and store the sensor data, and it will send all messages (10s interval) after the network recovery.
564 +== 2.4 Payload Decoder file ==
430 430  
566 +
567 +In TTN, use can add a custom payload so it shows friendly reading
568 +
569 +In the page (% style="color:#037691" %)**Applications ~-~-> Payload Formats ~-~-> Custom ~-~-> decoder**(%%) to add the decoder from: [[https:~~/~~/github.com/dragino/dragino-end-node-decoder>>https://github.com/dragino/dragino-end-node-decoder]]
570 +
571 +
572 +== 2.5 Datalog Feature ==
573 +
574 +
575 +Datalog Feature is to ensure IoT Server can get all sampling data from Sensor even if the LoRaWAN network is down. For each sampling, SW3L-LB will store the reading for future retrieving purposes.
576 +
577 +
578 +=== 2.5.1 Ways to get datalog via LoRaWAN ===
579 +
580 +
581 +Set PNACKMD=1, SW3L-LB will wait for ACK for every uplink, when there is no LoRaWAN network,SW3L-LB will mark these records with non-ack messages and store the sensor data, and it will send all messages (10s interval) after the network recovery.
582 +
431 431  * (((
432 -a) DDS75-LB will do an ACK check for data records sending to make sure every data arrive server.
584 +a) SW3L-LB will do an ACK check for data records sending to make sure every data arrive server.
433 433  )))
434 434  * (((
435 -b) DDS75-LB will send data in **CONFIRMED Mode** when PNACKMD=1, but DDS75-LB won't re-transmit the packet if it doesn't get ACK, it will just mark it as a NONE-ACK message. In a future uplink if DDS75-LB gets a ACK, DDS75-LB will consider there is a network connection and resend all NONE-ACK messages.
587 +b) SW3L-LB will send data in **CONFIRMED Mode** when PNACKMD=1, but SW3L-LB won't re-transmit the packet if it doesn't get ACK, it will just mark it as a NONE-ACK message. In a future uplink if SW3L-LB gets a ACK, SW3L-LB will consider there is a network connection and resend all NONE-ACK messages.
436 436  )))
437 437  
438 438  Below is the typical case for the auto-update datalog feature (Set PNACKMD=1)
... ... @@ -440,10 +440,10 @@
440 440  [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/WebHome/image-20220703111700-2.png?width=1119&height=381&rev=1.1||alt="图片-20220703111700-2.png" height="381" width="1119"]]
441 441  
442 442  
443 -=== 2.6.2 Unix TimeStamp ===
595 +=== 2.5.2 Unix TimeStamp ===
444 444  
445 445  
446 -DDS75-LB uses Unix TimeStamp format based on
598 +SW3L-LB uses Unix TimeStamp format based on
447 447  
448 448  [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/WebHome/image-20220523001219-11.png?width=627&height=97&rev=1.1||alt="图片-20220523001219-11.png" height="97" width="627"]]
449 449  
... ... @@ -457,17 +457,17 @@
457 457  So, we can use AT+TIMESTAMP=1611889405 or downlink 3060137afd00 to set the current time 2021 – Jan ~-~- 29 Friday 03:03:25
458 458  
459 459  
460 -=== 2.6.3 Set Device Time ===
612 +=== 2.5.3 Set Device Time ===
461 461  
462 462  
463 463  User need to set (% style="color:blue" %)**SYNCMOD=1**(%%) to enable sync time via MAC command.
464 464  
465 -Once DDS75-LB Joined LoRaWAN network, it will send the MAC command (DeviceTimeReq) and the server will reply with (DeviceTimeAns) to send the current time to DDS75-LB. If DDS75-LB fails to get the time from the server, DDS75-LB will use the internal time and wait for next time request (AT+SYNCTDC to set the time request period, default is 10 days).
617 +Once SW3L-LB Joined LoRaWAN network, it will send the MAC command (DeviceTimeReq) and the server will reply with (DeviceTimeAns) to send the current time to SW3L-LB. If SW3L-LB fails to get the time from the server, SW3L-LB will use the internal time and wait for next time request (AT+SYNCTDC to set the time request period, default is 10 days).
466 466  
467 467  (% style="color:red" %)**Note: LoRaWAN Server need to support LoRaWAN v1.0.3(MAC v1.0.3) or higher to support this MAC command feature, Chirpstack,TTN V3 v3 and loriot support but TTN V3 v2 doesn't support. If server doesn't support this command, it will through away uplink packet with this command, so user will lose the packet with time request for TTN V3 v2 if SYNCMOD=1.**
468 468  
469 469  
470 -=== 2.6.4 Poll sensor value ===
622 +=== 2.5.4 Poll sensor value ===
471 471  
472 472  
473 473  Users can poll sensor values based on timestamps. Below is the downlink command.
... ... @@ -490,24 +490,24 @@
490 490  )))
491 491  
492 492  (((
493 -Uplink Internal =5s,means DDS75-LB will send one packet every 5s. range 5~~255s.
645 +Uplink Internal =5s,means SW3L-LB will send one packet every 5s. range 5~~255s.
494 494  )))
495 495  
496 496  
497 -== 2.7 Frequency Plans ==
649 +== 2.6 Frequency Plans ==
498 498  
499 499  
500 -The DDS75-LB uses OTAA mode and below frequency plans by default. If user want to use it with different frequency plan, please refer the AT command sets.
652 +The SW3L-LB uses OTAA mode and below frequency plans by default. If user want to use it with different frequency plan, please refer the AT command sets.
501 501  
502 502  [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20Frequency%20Band/>>http://wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20Frequency%20Band/]]
503 503  
504 504  
505 -= 3. Configure DDS75-LB =
657 += 3. Configure SW3L-LB =
506 506  
507 507  == 3.1 Configure Methods ==
508 508  
509 509  
510 -DDS75-LB supports below configure method:
662 +SW3L-LB supports below configure method:
511 511  
512 512  * AT Command via Bluetooth Connection (**Recommended**): [[BLE Configure Instruction>>http://wiki.dragino.com/xwiki/bin/view/Main/BLE%20Bluetooth%20Remote%20Configure/]].
513 513  
... ... @@ -515,6 +515,7 @@
515 515  
516 516  * LoRaWAN Downlink.  Instruction for different platforms: See [[IoT LoRaWAN Server>>http://wiki.dragino.com/xwiki/bin/view/Main/]] section.
517 517  
670 +
518 518  == 3.2 General Commands ==
519 519  
520 520  
... ... @@ -529,10 +529,10 @@
529 529  [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/>>http://wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/]]
530 530  
531 531  
532 -== 3.3 Commands special design for DDS75-LB ==
685 +== 3.3 Commands special design for SW3L-LB ==
533 533  
534 534  
535 -These commands only valid for DDS75-LB, as below:
688 +These commands only valid for SW3L-LB, as below:
536 536  
537 537  
538 538  === 3.3.1 Set Transmit Interval Time ===
... ... @@ -577,9 +577,169 @@
577 577  Example 2: Downlink Payload: 0100003C  ~/~/ Set Transmit Interval (TDC) = 60 seconds
578 578  )))
579 579  
580 -=== 3.3.2 Set Interrupt Mode ===
581 581  
734 +=== 3.3.2 Quit AT Command ===
582 582  
736 +
737 +Feature: Quit AT Command mode, so user needs to input the password again before using AT Commands.
738 +
739 +(% style="color:blue" %)**AT Command: AT+DISAT**
740 +
741 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:452px" %)
742 +|=(% style="width: 155px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 198px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 99px;background-color:#D9E2F3;color:#0070C0" %)**Response**
743 +|(% style="width:155px" %)AT+DISAT|(% style="width:198px" %)Quit AT Commands mode|(% style="width:96px" %)OK
744 +
745 +(% style="color:blue" %)**Downlink Command:**
746 +
747 +No downlink command for this feature.
748 +
749 +
750 +=== 3.3.3 Get Device Status ===
751 +
752 +
753 +Send a LoRaWAN downlink to ask device send Alarm settings.
754 +
755 +(% style="color:blue" %)**Downlink Payload:  **(%%)0x26 01
756 +
757 +Sensor will upload Device Status via FPORT=5. See payload section for detail.
758 +
759 +
760 +=== 3.3.4 Alarm for continuously water flow ===
761 +
762 +
763 +(((
764 +This feature is to monitor and send Alarm for continuously water flow.
765 +)))
766 +
767 +(((
768 +Example case is for Toilet water monitoring, if some one push toilet button, the toilet will have water flow. If the toilet button has broken and can't returned to original state, the water flow will keep for hours or days which cause huge waste for water.
769 +)))
770 +
771 +(((
772 +To monitor this faulty and send alarm, there are two settings:
773 +)))
774 +
775 +* (((
776 +(% style="color:#4f81bd" %)**Stop Duration: Unit: Second**
777 +)))
778 +
779 +(((
780 +Default: 15s, If SW3L-LB didn't see any water flow in 15s, SW3L-LB will consider stop of water flow event.
781 +)))
782 +
783 +* (((
784 +(% style="color:#4f81bd" %)**Alarm Timer: Units: Minute; Default 0 minutes (means Alarm disable)**
785 +)))
786 +
787 +(((
788 +**Example:** 3 minutes, if SW3L-LB detect a start of water flow event and didn't detect a stop event within Alarm timer, SW3L-LB will send an Alarm to indicate a water flow abnormal alarm.
789 +)))
790 +
791 +(((
792 +So for example, If we set stop duration=15s and Alarm Timer=3minutes. If the toilet water flow continuously for more than 3 minutes, Sensor will send an alarm (in Confirmed MODE) to platform.
793 +)))
794 +
795 +(((
796 +(% style="color:red" %)**Note:** **After this alarm is send, sensor will consider a stop of water flow and count for another new event. So if water flow waste last for 1 hour, Sensor will keep sending alarm every 3 minutes.**
797 +)))
798 +
799 +(((
800 +(% style="color:#4f81bd" %)**AT Command**(%%) to configure:
801 +)))
802 +
803 +* (((
804 +AT+PTRIG=15,3  ~-~-> Set Stop duration: 15s, Alarm Timer: 3 minutes.
805 +)))
806 +
807 +* (((
808 +AT+ PTRIG=15,0  ~-~-> Default Value, disable water waste Alarm.
809 +)))
810 +
811 +(((
812 +(% style="color:#4f81bd" %)**Downlink Command**(%%) to configure: 
813 +)))
814 +
815 +(((
816 +Command: **0xAA aa bb cc**
817 +)))
818 +
819 +(((
820 +AA: Command Type Code
821 +)))
822 +
823 +(((
824 +aa: Stop duration
825 +)))
826 +
827 +(((
828 +bb cc: Alarm Timer
829 +)))
830 +
831 +(((
832 +If user send 0xAA 0F 00 03: equal to AT+PTRIG=15,3
833 +)))
834 +
835 +
836 +=== 3.3.5 Clear Flash Record ===
837 +
838 +
839 +Feature: Clear flash storage for data log feature.
840 +
841 +(% style="color:blue" %)**AT Command: AT+CLRDTA**
842 +
843 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:500px" %)
844 +|=(% style="width: 157px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 169px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 174px;background-color:#D9E2F3;color:#0070C0" %)**Response**
845 +|(% style="width:157px" %)AT+CLRDTA|(% style="width:169px" %)Clear flash storage for data log feature.|Clear all stored sensor data… OK
846 +
847 +(((
848 +(% style="color:blue" %)**Downlink Command:**
849 +)))
850 +
851 +(((
852 +* **Example**: 0xA301  ~/~/  Same as AT+CLRDTA
853 +)))
854 +
855 +
856 +
857 +=== 3.3.6 Set the calculate flag ===
858 +
859 +
860 +Feature: Set the calculate flag
861 +
862 +(% style="color:blue" %)**AT Command: AT+CALCFLAG**
863 +
864 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:461px" %)
865 +|=(% style="width: 158px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 193px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 110px;background-color:#D9E2F3;color:#0070C0" %)**Response**
866 +|(% style="width:158px" %)AT+CALCFLAG =1|(% style="width:192px" %)Set the calculate flag to 1.|(% style="width:109px" %)OK
867 +|(% style="width:158px" %)AT+CALCFLAG =2|(% style="width:192px" %)Set the calculate flag to 2.|(% style="width:109px" %)OK
868 +
869 +(% style="color:blue" %)**Downlink Command:**
870 +
871 +* **Example**: 0XA501  ~/~/  Same as AT+CALCFLAG =1
872 +
873 +
874 +=== 3.3.7 Set count number ===
875 +
876 +
877 +Feature: Manually set the count number
878 +
879 +(% style="color:blue" %)**AT Command: AT+SETCNT**
880 +
881 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:479px" %)
882 +|=(% style="width: 160px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 223px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 96px;background-color:#D9E2F3;color:#0070C0" %)**Response**
883 +|(% style="width:160px" %)AT+ SETCNT =0|(% style="width:221px" %)Set the count number to 0.|(% style="width:95px" %)OK
884 +|(% style="width:160px" %)AT+ SETCNT =100|(% style="width:221px" %)Set the count number to 100.|(% style="width:95px" %)OK
885 +
886 +(% style="color:blue" %)**Downlink Command:**
887 +
888 +* **Example**: 0xA6000001  ~/~/  Same as AT+ SETCNT =1
889 +
890 +* **Example**: 0xA6000064  ~/~/  Same as AT+ SETCNT =100
891 +
892 +
893 +=== 3.3.8 Set Interrupt Mode ===
894 +
895 +
583 583  Feature, Set Interrupt mode for PA8 of pin.
584 584  
585 585  When AT+INTMOD=0 is set, PA8 is used as a digital input port.
... ... @@ -611,101 +611,71 @@
611 611  
612 612  * Example 2: Downlink Payload: 06000003  ~/~/  Set the interrupt mode to rising edge trigger
613 613  
614 -= 4. Battery & Power Consumption =
615 615  
928 +=== 3.3.9 Set work mode ===
616 616  
617 -DDS75-LB use ER26500 + SPC1520 battery pack. See below link for detail information about the battery info and how to replace.
618 618  
619 -[[**Battery Info & Power Consumption Analyze**>>http://wiki.dragino.com/xwiki/bin/view/Main/How%20to%20calculate%20the%20battery%20life%20of%20Dragino%20sensors%3F/]] .
931 +Feature: Manually set the work mode
620 620  
621 621  
622 -= 5. OTA Firmware update =
934 +(% style="color:blue" %)**AT Command: AT+MOD**
623 623  
936 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:463px" %)
937 +|=(% style="width: 162px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 193px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 108px;background-color:#D9E2F3;color:#0070C0" %)**Response**
938 +|(% style="width:162px" %)AT+MOD=0|(% style="width:191px" %)Set the work mode to 0.|(% style="width:106px" %)OK
939 +|(% style="width:162px" %)AT+MOD=1|(% style="width:191px" %)Set the work mode to 1|(% style="width:106px" %)OK
624 624  
625 -(% class="wikigeneratedid" %)
626 -User can change firmware DDS75-LB to:
941 +(% style="color:blue" %)**Downlink Command:**
627 627  
628 -* Change Frequency band/ region.
943 +* **Example: **0x0A00  ~/~/  Same as AT+MOD=0
629 629  
630 -* Update with new features.
945 +* **Example:** 0x0A01  ~/~/  Same as AT+MOD=1
631 631  
632 -* Fix bugs.
633 633  
634 -Firmware and changelog can be downloaded from : **[[Firmware download link>>url:https://www.dropbox.com/sh/7la95mae0fn03xe/AACtzs-32m22TLb75B-iIr-Qa?dl=0]]**
948 += 4. Battery & Power Consumption =
635 635  
636 -Methods to Update Firmware:
637 637  
638 -* (Recommanded way) OTA firmware update via wireless:  [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/Firmware%20OTA%20Update%20for%20Sensors/>>url:http://wiki.dragino.com/xwiki/bin/view/Main/Firmware%20OTA%20Update%20for%20Sensors/]]
951 +SW3L-LB use ER26500 + SPC1520 battery pack. See below link for detail information about the battery info and how to replace.
639 639  
640 -* Update through UART TTL interface: **[[Instruction>>url:http://wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H1.LoRaSTv4baseHardware]]**.
953 +[[**Battery Info & Power Consumption Analyze**>>http://wiki.dragino.com/xwiki/bin/view/Main/How%20to%20calculate%20the%20battery%20life%20of%20Dragino%20sensors%3F/]] .
641 641  
642 -= 6. FAQ =
643 643  
956 += 5. OTA Firmware update =
644 644  
645 -== 6.1  What is the frequency plan for DDS75-LB? ==
646 646  
959 +(% class="wikigeneratedid" %)
960 +User can change firmware SW3L-LB to:
647 647  
648 -DDS75-LB use the same frequency as other Dragino products. User can see the detail from this link:  [[Introduction>>doc:Main.End Device Frequency Band.WebHome||anchor="H1.Introduction"]]
962 +* Change Frequency band/ region.
649 649  
964 +* Update with new features.
650 650  
651 -== 6.2  Can I use DDS75-LB in condensation environment? ==
966 +* Fix bugs.
652 652  
968 +Firmware and changelog can be downloaded from : **[[Firmware download link>>url:https://www.dropbox.com/sh/kwqv57tp6pejias/AAAopYMATh1GM6fZ-VRCLrpDa?dl=0]]**
653 653  
654 -DDS75-LB is not suitable to be used in condensation environment. Condensation on the DDS75-LB probe will affect the reading and always got 0.
970 +Methods to Update Firmware:
655 655  
972 +* (Recommanded way) OTA firmware update via wireless:   [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/Firmware%20OTA%20Update%20for%20Sensors/>>url:http://wiki.dragino.com/xwiki/bin/view/Main/Firmware%20OTA%20Update%20for%20Sensors/]]
656 656  
657 -= 7.  Trouble Shooting =
974 +* Update through UART TTL interface. **[[Instruction>>url:http://wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H1.LoRaSTv4baseHardware]]**.
658 658  
659 -== 7.1  Why I can't join TTN V3 in US915 / AU915 bands? ==
660 660  
977 += 6. FAQ =
661 661  
662 -It is due to channel mapping. Please see below link:  [[Frequency band>>doc:Main.LoRaWAN Communication Debug.WebHome||anchor="H2.NoticeofUS9152FCN4702FAU915Frequencyband"]]
979 +== 6.1  AT Commands input doesn't work ==
663 663  
664 664  
665 -== 7. AT Command input doesn't work ==
982 +In the case if user can see the console output but can't type input to the device. Please check if you already include the (% style="color:green" %)**ENTER**(%%) while sending out the command. Some serial tool doesn't send (% style="color:green" %)**ENTER**(%%) while press the send key, user need to add ENTER in their string.
666 666  
667 667  
668 -In the case if user can see the console output but can't type input to the device. Please check if you already include the (% style="color:blue" %)**ENTER**(%%) while sending out the command. Some serial tool doesn't send (% style="color:blue" %)**ENTER**(%%) while press the send key, user need to add ENTER in their string.
985 += 7. Order Info =
669 669  
670 670  
671 -== 7.3  Why does the sensor reading show 0 or "No sensor" ==
988 +Part Number: (% style="color:blue" %)**SW3L-LB-XXX-YYY**
672 672  
990 +(% style="color:red" %)**XXX**(%%): The default frequency band
673 673  
674 -~1. The measurement object is very close to the sensor, but in the blind spot of the sensor.
675 -
676 -2. Sensor wiring is disconnected
677 -
678 -3. Not using the correct decoder
679 -
680 -
681 -== 7.4  Abnormal readings The gap between multiple readings is too large or the gap between the readings and the actual value is too large ==
682 -
683 -
684 -1) Please check if there is something on the probe affecting its measurement (condensed water, volatile oil, etc.)
685 -
686 -2) Does it change with temperature, temperature will affect its measurement
687 -
688 -3) If abnormal data occurs, you can turn on DEBUG mode, Please use downlink or AT COMMAN to enter DEBUG mode.
689 -
690 -downlink command: (% style="color:blue" %)**F1 01**(%%), AT command: (% style="color:blue" %)**AT+DDEBUG=1**
691 -
692 -4) After entering the debug mode, it will send 20 pieces of data at a time, and you can send its uplink to us for analysis
693 -
694 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDDS75%20-%20LoRaWAN%20Distance%20Detection%20Sensor%20User%20Manual/WebHome/image-20230113135125-2.png?width=1057&height=136&rev=1.1||alt="image-20230113135125-2.png"]]
695 -
696 -
697 -Its original payload will be longer than other data. Even though it is being parsed, it can be seen that it is abnormal data.
698 -
699 -Please send the data to us for check.
700 -
701 -
702 -= 8. Order Info =
703 -
704 -
705 -Part Number: (% style="color:blue" %)**DDS75-LB-XXX**
706 -
707 -(% style="color:red" %)**XXX**(%%): **The default frequency band**
708 -
709 709  * (% style="color:red" %)**AS923**(%%): LoRaWAN AS923 band
710 710  
711 711  * (% style="color:red" %)**AU915**(%%): LoRaWAN AU915 band
... ... @@ -722,13 +722,43 @@
722 722  
723 723  * (% style="color:red" %)**CN470**(%%): LoRaWAN CN470 band
724 724  
1008 +(((
1009 +(% style="color:blue" %)**YYY**(%%): Flow Sensor Model:
1010 +)))
725 725  
726 -= 9. ​Packing Info =
1012 +(((
1013 + **004:** DW-004 Flow Sensor: diameter: G1/2” / DN15.  450 pulse = 1 L
1014 +)))
727 727  
1016 +(((
1017 + **006:** DW-006 Flow Sensor: diameter: G3/4” / DN20. 390 pulse = 1 L
1018 +)))
728 728  
1020 +(((
1021 + **010:** DW-010 Flow Sensor: diameter: G 1” / DN25. 64 pulse = 1 L
1022 +)))
1023 +
1024 +* (((
1025 +calculate flag=0: for SW3L-004 Flow Sensor: 450 pulse = 1 L
1026 +)))
1027 +
1028 +* (((
1029 +calculate flag=1: for SW3L-006 Flow Sensor: 390 pulse = 1 L
1030 +)))
1031 +
1032 +* (((
1033 +calculate flag=2: for SW3L-010 Flow Sensor: 64  pulse = 1 L
1034 +
1035 +
1036 +
1037 +)))
1038 +
1039 += 8. ​Packing Info =
1040 +
1041 +
729 729  (% style="color:#037691" %)**Package Includes**:
730 730  
731 -* DDS75-LB LoRaWAN Distance Detection Sensor x 1
1044 +* SW3L-LB LoRaWAN Flow Sensor
732 732  
733 733  (% style="color:#037691" %)**Dimension and weight**:
734 734  
... ... @@ -741,7 +741,7 @@
741 741  * Weight / pcs : g
742 742  
743 743  
744 -= 10. Support =
1057 += 9. Support =
745 745  
746 746  
747 747  * Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule.