Changes for page DS20L -- LoRaWAN Smart Distance Detector User Manual 01
Last modified by Mengting Qiu on 2023/12/14 11:15
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -22,13 +22,13 @@ 22 22 23 23 It detects the distance(% style="color:blue" %)** between the measured object and the sensor**(%%), and uploads the value via wireless to LoRaWAN IoT Server. 24 24 25 -The LoRa wireless technology used in DDS75-LB allows device to send data and reach extremely long ranges at low data-rates. It provides ultra-long range spread spectrum communication and high interference immunity whilst minimizing current consumption.25 +The LoRa wireless technology used in SW3L-LB allows device to send data and reach extremely long ranges at low data-rates. It provides ultra-long range spread spectrum communication and high interference immunity whilst minimizing current consumption. 26 26 27 - DDS75-LB (% style="color:blue" %)**supports BLE configure**(%%) and (% style="color:blue" %)**wireless OTA update**(%%) which make user easy to use.27 +SW3L-LB (% style="color:blue" %)**supports BLE configure**(%%) and (% style="color:blue" %)**wireless OTA update**(%%) which make user easy to use. 28 28 29 - DDS75-LB is powered by (% style="color:blue" %)**8500mAh Li-SOCI2 battery**(%%), it is designed for long term use up to 5 years.29 +SW3L-LB is powered by (% style="color:blue" %)**8500mAh Li-SOCI2 battery**(%%), it is designed for long term use up to 5 years. 30 30 31 -Each DDS75-LB is pre-load with a set of unique keys for LoRaWAN registrations, register these keys to local LoRaWAN server and it will auto connect after power on.31 +Each SW3L-LB is pre-load with a set of unique keys for LoRaWAN registrations, register these keys to local LoRaWAN server and it will auto connect after power on. 32 32 33 33 [[image:image-20230612170943-2.png||height="525" width="912"]] 34 34 ... ... @@ -178,8 +178,8 @@ 178 178 [[image:image-20230523174230-1.png]] 179 179 180 180 181 +== == 181 181 182 - 183 183 == 2.10 Mechanical == 184 184 185 185 ... ... @@ -268,6 +268,7 @@ 268 268 269 269 270 270 ((( 271 +((( 271 271 DDS75-LB will uplink payload via LoRaWAN with below payload format: 272 272 ))) 273 273 ... ... @@ -275,9 +275,12 @@ 275 275 Uplink payload includes in total 4 bytes. 276 276 Payload for firmware version v1.1.4. . Before v1.1.3, there is on two fields: BAT and Distance 277 277 ))) 279 +))) 278 278 281 +((( 282 + 283 +))) 279 279 280 - 281 281 (% border="1" cellspacing="5" style="background-color:#f2f2f2; width:510px" %) 282 282 |=(% style="width: 62.5px;background-color:#D9E2F3;color:#0070C0" %)((( 283 283 **Size(bytes)** ... ... @@ -319,8 +319,6 @@ 319 319 * If the sensor value is 0x0000, it means system doesn't detect ultrasonic sensor. 320 320 * If the sensor value lower than 0x0118 (280mm), the sensor value will be invalid. Since v1.1.4, all value lower than 280mm will be set to 0x0014(20mm) which means the value is invalid. 321 321 322 - 323 - 324 324 === 2.3.3 Interrupt Pin === 325 325 326 326 ... ... @@ -421,19 +421,19 @@ 421 421 == 2.6 Datalog Feature == 422 422 423 423 424 -Datalog Feature is to ensure IoT Server can get all sampling data from Sensor even if the LoRaWAN network is down. For each sampling, DDS75-LB will store the reading for future retrieving purposes.426 +Datalog Feature is to ensure IoT Server can get all sampling data from Sensor even if the LoRaWAN network is down. For each sampling, SW3L-LB will store the reading for future retrieving purposes. 425 425 426 426 427 427 === 2.6.1 Ways to get datalog via LoRaWAN === 428 428 429 429 430 -Set PNACKMD=1, DDS75-LB will wait for ACK for every uplink, when there is no LoRaWAN network,DDS75-LB will mark these records with non-ack messages and store the sensor data, and it will send all messages (10s interval) after the network recovery.432 +Set PNACKMD=1, SW3L-LB will wait for ACK for every uplink, when there is no LoRaWAN network,SW3L-LB will mark these records with non-ack messages and store the sensor data, and it will send all messages (10s interval) after the network recovery. 431 431 432 432 * ((( 433 -a) DDS75-LB will do an ACK check for data records sending to make sure every data arrive server.435 +a) SW3L-LB will do an ACK check for data records sending to make sure every data arrive server. 434 434 ))) 435 435 * ((( 436 -b) DDS75-LB will send data in **CONFIRMED Mode** when PNACKMD=1, butDDS75-LB won't re-transmit the packet if it doesn't get ACK, it will just mark it as a NONE-ACK message. In a future uplink ifDDS75-LB gets a ACK,DDS75-LB will consider there is a network connection and resend all NONE-ACK messages.438 +b) SW3L-LB will send data in **CONFIRMED Mode** when PNACKMD=1, but SW3L-LB won't re-transmit the packet if it doesn't get ACK, it will just mark it as a NONE-ACK message. In a future uplink if SW3L-LB gets a ACK, SW3L-LB will consider there is a network connection and resend all NONE-ACK messages. 437 437 ))) 438 438 439 439 Below is the typical case for the auto-update datalog feature (Set PNACKMD=1) ... ... @@ -444,7 +444,7 @@ 444 444 === 2.6.2 Unix TimeStamp === 445 445 446 446 447 - DDS75-LB uses Unix TimeStamp format based on449 +SW3L-LB uses Unix TimeStamp format based on 448 448 449 449 [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/WebHome/image-20220523001219-11.png?width=627&height=97&rev=1.1||alt="图片-20220523001219-11.png" height="97" width="627"]] 450 450 ... ... @@ -463,7 +463,7 @@ 463 463 464 464 User need to set (% style="color:blue" %)**SYNCMOD=1**(%%) to enable sync time via MAC command. 465 465 466 -Once DDS75-LB Joined LoRaWAN network, it will send the MAC command (DeviceTimeReq) and the server will reply with (DeviceTimeAns) to send the current time toDDS75-LB. IfDDS75-LB fails to get the time from the server,DDS75-LB will use the internal time and wait for next time request (AT+SYNCTDC to set the time request period, default is 10 days).468 +Once SW3L-LB Joined LoRaWAN network, it will send the MAC command (DeviceTimeReq) and the server will reply with (DeviceTimeAns) to send the current time to SW3L-LB. If SW3L-LB fails to get the time from the server, SW3L-LB will use the internal time and wait for next time request (AT+SYNCTDC to set the time request period, default is 10 days). 467 467 468 468 (% style="color:red" %)**Note: LoRaWAN Server need to support LoRaWAN v1.0.3(MAC v1.0.3) or higher to support this MAC command feature, Chirpstack,TTN V3 v3 and loriot support but TTN V3 v2 doesn't support. If server doesn't support this command, it will through away uplink packet with this command, so user will lose the packet with time request for TTN V3 v2 if SYNCMOD=1.** 469 469 ... ... @@ -491,7 +491,7 @@ 491 491 ))) 492 492 493 493 ((( 494 -Uplink Internal =5s,means DDS75-LB will send one packet every 5s. range 5~~255s.496 +Uplink Internal =5s,means SW3L-LB will send one packet every 5s. range 5~~255s. 495 495 ))) 496 496 497 497 ... ... @@ -498,17 +498,17 @@ 498 498 == 2.7 Frequency Plans == 499 499 500 500 501 -The DDS75-LB uses OTAA mode and below frequency plans by default. If user want to use it with different frequency plan, please refer the AT command sets.503 +The SW3L-LB uses OTAA mode and below frequency plans by default. If user want to use it with different frequency plan, please refer the AT command sets. 502 502 503 503 [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20Frequency%20Band/>>http://wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20Frequency%20Band/]] 504 504 505 505 506 -= 3. Configure DDS75-LB =508 += 3. Configure SW3L-LB = 507 507 508 508 == 3.1 Configure Methods == 509 509 510 510 511 - DDS75-LB supports below configure method:513 +SW3L-LB supports below configure method: 512 512 513 513 * AT Command via Bluetooth Connection (**Recommended**): [[BLE Configure Instruction>>http://wiki.dragino.com/xwiki/bin/view/Main/BLE%20Bluetooth%20Remote%20Configure/]]. 514 514 ... ... @@ -530,10 +530,10 @@ 530 530 [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/>>http://wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/]] 531 531 532 532 533 -== 3.3 Commands special design for DDS75-LB ==535 +== 3.3 Commands special design for SW3L-LB == 534 534 535 535 536 -These commands only valid for DDS75-LB, as below:538 +These commands only valid for SW3L-LB, as below: 537 537 538 538 539 539 === 3.3.1 Set Transmit Interval Time === ... ... @@ -578,135 +578,259 @@ 578 578 Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds 579 579 ))) 580 580 581 -=== 3.3.2 Set InterruptMode===583 +=== 3.3.2 Quit AT Command === 582 582 583 583 584 -Feature ,SetInterruptmodeforPA8of pin.586 +Feature: Quit AT Command mode, so user needs to input the password again before using AT Commands. 585 585 586 - WhenAT+INTMOD=0 isset, PA8 isusedasaigitalinput port.588 +(% style="color:blue" %)**AT Command: AT+DISAT** 587 587 588 -(% style="color:blue" %)**AT Command: AT+INTMOD** 590 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:452px" %) 591 +|=(% style="width: 155px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 198px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 99px;background-color:#D9E2F3;color:#0070C0" %)**Response** 592 +|(% style="width:155px" %)AT+DISAT|(% style="width:198px" %)Quit AT Commands mode|(% style="width:96px" %)OK 589 589 590 -(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %) 591 -|=(% style="width: 155px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 197px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 158px;background-color:#D9E2F3;color:#0070C0" %)**Response** 592 -|(% style="width:154px" %)AT+INTMOD=?|(% style="width:196px" %)Show current interrupt mode|(% style="width:157px" %)((( 593 -0 594 -OK 595 -the mode is 0 =Disable Interrupt 594 +(% style="color:blue" %)**Downlink Command:** 595 + 596 +No downlink command for this feature. 597 + 598 + 599 +=== 3.3.3 Get Device Status === 600 + 601 + 602 +Send a LoRaWAN downlink to ask device send Alarm settings. 603 + 604 +(% style="color:blue" %)**Downlink Payload: **(%%)0x26 01 605 + 606 +Sensor will upload Device Status via FPORT=5. See payload section for detail. 607 + 608 + 609 +=== 3.3.4 Alarm for continuously water flow === 610 + 611 + 612 +((( 613 +This feature is to monitor and send Alarm for continuously water flow. 596 596 ))) 597 -|(% style="width:154px" %)AT+INTMOD=2|(% style="width:196px" %)((( 598 -Set Transmit Interval 599 -0. (Disable Interrupt), 600 -~1. (Trigger by rising and falling edge) 601 -2. (Trigger by falling edge) 602 -3. (Trigger by rising edge) 603 -)))|(% style="width:157px" %)OK 604 604 605 -(% style="color:blue" %)**Downlink Command: 0x06** 616 +((( 617 +Example case is for Toilet water monitoring, if some one push toilet button, the toilet will have water flow. If the toilet button has broken and can't returned to original state, the water flow will keep for hours or days which cause huge waste for water. 618 +))) 606 606 607 -Format: Command Code (0x06) followed by 3 bytes. 620 +((( 621 +To monitor this faulty and send alarm, there are two settings: 622 +))) 608 608 609 -This means that the interrupt mode of the end node is set to 0x000003=3 (rising edge trigger), and the type code is 06. 624 +* ((( 625 +(% style="color:#4f81bd" %)**Stop Duration: Unit: Second** 626 +))) 610 610 611 -* Example 1: Downlink Payload: 06000000 ~/~/ Turn off interrupt mode 628 +((( 629 +Default: 15s, If SW3L-LB didn't see any water flow in 15s, SW3L-LB will consider stop of water flow event. 630 +))) 612 612 613 -* Example 2: Downlink Payload: 06000003 ~/~/ Set the interrupt mode to rising edge trigger 632 +* ((( 633 +(% style="color:#4f81bd" %)**Alarm Timer: Units: Minute; Default 0 minutes (means Alarm disable)** 634 +))) 614 614 615 -= 4. Battery & Power Consumption = 636 +((( 637 +**Example:** 3 minutes, if SW3L-LB detect a start of water flow event and didn't detect a stop event within Alarm timer, SW3L-LB will send an Alarm to indicate a water flow abnormal alarm. 638 +))) 616 616 640 +((( 641 +So for example, If we set stop duration=15s and Alarm Timer=3minutes. If the toilet water flow continuously for more than 3 minutes, Sensor will send an alarm (in Confirmed MODE) to platform. 642 +))) 617 617 618 -DDS75-LB use ER26500 + SPC1520 battery pack. See below link for detail information about the battery info and how to replace. 644 +((( 645 +(% style="color:red" %)**Note:** **After this alarm is send, sensor will consider a stop of water flow and count for another new event. So if water flow waste last for 1 hour, Sensor will keep sending alarm every 3 minutes.** 646 +))) 619 619 620 -[[**Battery Info & Power Consumption Analyze**>>http://wiki.dragino.com/xwiki/bin/view/Main/How%20to%20calculate%20the%20battery%20life%20of%20Dragino%20sensors%3F/]] . 648 +((( 649 +(% style="color:#4f81bd" %)**AT Command**(%%) to configure: 650 +))) 621 621 652 +* ((( 653 +AT+PTRIG=15,3 ~-~-> Set Stop duration: 15s, Alarm Timer: 3 minutes. 654 +))) 622 622 623 -= 5. OTA Firmware update = 656 +* ((( 657 +AT+ PTRIG=15,0 ~-~-> Default Value, disable water waste Alarm. 658 +))) 624 624 660 +((( 661 +(% style="color:#4f81bd" %)**Downlink Command**(%%) to configure: 662 +))) 625 625 626 -(% class="wikigeneratedid" %) 627 -User can change firmware DDS75-LB to: 664 +((( 665 +Command: **0xAA aa bb cc** 666 +))) 628 628 629 -* Change Frequency band/ region. 668 +((( 669 +AA: Command Type Code 670 +))) 630 630 631 -* Update with new features. 672 +((( 673 +aa: Stop duration 674 +))) 632 632 633 -* Fix bugs. 676 +((( 677 +bb cc: Alarm Timer 678 +))) 634 634 635 -Firmware and changelog can be downloaded from : **[[Firmware download link>>url:https://www.dropbox.com/sh/7la95mae0fn03xe/AACtzs-32m22TLb75B-iIr-Qa?dl=0]]** 680 +((( 681 +If user send 0xAA 0F 00 03: equal to AT+PTRIG=15,3 682 +))) 636 636 637 -Methods to Update Firmware: 638 638 639 - *(Recommandedway) OTA firmwareupdate via wireless:[[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/Firmware%20OTA%20Update%20for%20Sensors/>>url:http://wiki.dragino.com/xwiki/bin/view/Main/Firmware%20OTA%20Update%20for%20Sensors/]]685 +=== 3.3.5 Clear Flash Record === 640 640 641 -* Update through UART TTL interface. **[[Instruction>>url:http://wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H1.LoRaSTv4baseHardware]]**. 642 642 643 - =6.FAQ=688 +Feature: Clear flash storage for data log feature. 644 644 690 +(% style="color:blue" %)**AT Command: AT+CLRDTA** 645 645 646 -== 6.1 What is the frequency plan for DDS75-LB? == 692 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:500px" %) 693 +|=(% style="width: 157px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 169px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 174px;background-color:#D9E2F3;color:#0070C0" %)**Response** 694 +|(% style="width:157px" %)AT+CLRDTA|(% style="width:169px" %)Clear flash storage for data log feature.|Clear all stored sensor data… OK 647 647 696 +((( 697 +(% style="color:blue" %)**Downlink Command:** 698 +))) 648 648 649 -DDS75-LB use the same frequency as other Dragino products. User can see the detail from this link: [[Introduction>>doc:Main.End Device Frequency Band.WebHome||anchor="H1.Introduction"]] 700 +((( 701 +* **Example**: 0xA301 ~/~/ Same as AT+CLRDTA 702 +))) 650 650 651 651 652 -== 6.2 Can I use DDS75-LB in condensation environment? == 653 653 706 +=== 3.3.6 Set the calculate flag === 654 654 655 -DDS75-LB is not suitable to be used in condensation environment. Condensation on the DDS75-LB probe will affect the reading and always got 0. 656 656 709 +Feature: Set the calculate flag 657 657 658 - =7. TroubleShooting=711 +(% style="color:blue" %)**AT Command: AT+CALCFLAG** 659 659 660 -== 7.1 Why I can't join TTN V3 in US915 / AU915 bands? == 713 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:461px" %) 714 +|=(% style="width: 158px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 193px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 110px;background-color:#D9E2F3;color:#0070C0" %)**Response** 715 +|(% style="width:158px" %)AT+CALCFLAG =1|(% style="width:192px" %)Set the calculate flag to 1.|(% style="width:109px" %)OK 716 +|(% style="width:158px" %)AT+CALCFLAG =2|(% style="width:192px" %)Set the calculate flag to 2.|(% style="width:109px" %)OK 661 661 718 +(% style="color:blue" %)**Downlink Command:** 662 662 663 - Itis due to channelmapping. Pleaseseebelowlink:[[Frequencyband>>doc:Main.LoRaWAN Communication Debug.WebHome||anchor="H2.NoticeofUS9152FCN4702FAU915Frequencyband"]]720 +* **Example**: 0XA501 ~/~/ Same as AT+CALCFLAG =1 664 664 722 +=== 3.3.7 Set count number === 665 665 666 -== 7.2 AT Command input doesn't work == 667 667 725 +Feature: Manually set the count number 668 668 669 - In the case if user can see the console output but can't type input to the device. Please check if you already include the(% style="color:blue" %)**ENTER**(%%)while sendingout the command. Some serial tool doesn't send (% style="color:blue"%)**ENTER**(%%) while press the send key, user need to add ENTER in their string.727 +(% style="color:blue" %)**AT Command: AT+SETCNT** 670 670 729 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:479px" %) 730 +|=(% style="width: 160px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 223px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 96px;background-color:#D9E2F3;color:#0070C0" %)**Response** 731 +|(% style="width:160px" %)AT+ SETCNT =0|(% style="width:221px" %)Set the count number to 0.|(% style="width:95px" %)OK 732 +|(% style="width:160px" %)AT+ SETCNT =100|(% style="width:221px" %)Set the count number to 100.|(% style="width:95px" %)OK 671 671 672 - ==7.3 Why doeshesensorreadingshow0or "No sensor" ==734 +(% style="color:blue" %)**Downlink Command:** 673 673 736 +* **Example**: 0xA6000001 ~/~/ Same as AT+ SETCNT =1 674 674 675 - ~1.The measurementobjectisveryclosetothesensor,but in the blindspotofthesensor.738 +* **Example**: 0xA6000064 ~/~/ Same as AT+ SETCNT =100 676 676 677 - 2. Sensorwiringis disconnected740 +=== 3.3.8 Set Interrupt Mode === 678 678 679 -3. Not using the correct decoder 680 680 743 +Feature, Set Interrupt mode for PA8 of pin. 681 681 682 - ==5.4AbnormalreadingsThegap betweenmultiplereadingsistoo largeor the gapbetween the readings andtheactualvalueistoolarge ==745 +When AT+INTMOD=0 is set, PA8 is used as a digital input port. 683 683 747 +(% style="color:blue" %)**AT Command: AT+INTMOD** 684 684 685 -1) Please check if there is something on the probe affecting its measurement (condensed water, volatile oil, etc.) 749 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %) 750 +|=(% style="width: 155px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 197px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 158px;background-color:#D9E2F3;color:#0070C0" %)**Response** 751 +|(% style="width:154px" %)AT+INTMOD=?|(% style="width:196px" %)Show current interrupt mode|(% style="width:157px" %)((( 752 +0 753 +OK 754 +the mode is 0 =Disable Interrupt 755 +))) 756 +|(% style="width:154px" %)AT+INTMOD=2|(% style="width:196px" %)((( 757 +Set Transmit Interval 758 +0. (Disable Interrupt), 759 +~1. (Trigger by rising and falling edge) 760 +2. (Trigger by falling edge) 761 +3. (Trigger by rising edge) 762 +)))|(% style="width:157px" %)OK 686 686 687 - 2)Doesitchangewith temperature,temperaturewill affectitsmeasurement764 +(% style="color:blue" %)**Downlink Command: 0x06** 688 688 689 - 3) If abnormal dataoccurs, you canturnon DEBUG mode,Pleaseuse downlinkorATCOMMANtoenter DEBUG mode.766 +Format: Command Code (0x06) followed by 3 bytes. 690 690 691 - downlinkcommand:(%style="color:blue"%)**F101**(%%),AT command:(%style="color:blue"%)**AT+DDEBUG=1**768 +This means that the interrupt mode of the end node is set to 0x000003=3 (rising edge trigger), and the type code is 06. 692 692 693 - 4)After entering the debugmode,itwill send20piecesofdataatatime,andyoucan senditsuplinktous for analysis770 +* Example 1: Downlink Payload: 06000000 ~/~/ Turn off interrupt mode 694 694 695 - [[image:image-20230113135125-2.png||height="136"width="1057"]]772 +* Example 2: Downlink Payload: 06000003 ~/~/ Set the interrupt mode to rising edge trigger 696 696 774 +=== 3.3.9 Set work mode === 697 697 698 -Its original payload will be longer than other data. Even though it is being parsed, it can be seen that it is abnormal data. 699 699 700 - Please sendthedata tous forcheck.777 +Feature: Manually set the work mode 701 701 702 702 703 - =8. OrderInfo=780 +(% style="color:blue" %)**AT Command: AT+MOD** 704 704 782 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:463px" %) 783 +|=(% style="width: 162px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 193px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 108px;background-color:#D9E2F3;color:#0070C0" %)**Response** 784 +|(% style="width:162px" %)AT+MOD=0|(% style="width:191px" %)Set the work mode to 0.|(% style="width:106px" %)OK 785 +|(% style="width:162px" %)AT+MOD=1|(% style="width:191px" %)Set the work mode to 1|(% style="width:106px" %)OK 705 705 706 - Part Number:(% style="color:blue" %)**DDS75-LB-XXX**787 +(% style="color:blue" %)**Downlink Command:** 707 707 708 - (%style="color:red"%)**XXX**(%%):**Thedefaultfrequencyband**789 +* **Example: **0x0A00 ~/~/ Same as AT+MOD=0 709 709 791 +* **Example:** 0x0A01 ~/~/ Same as AT+MOD=1 792 + 793 += 4. Battery & Power Consumption = 794 + 795 + 796 +SW3L-LB use ER26500 + SPC1520 battery pack. See below link for detail information about the battery info and how to replace. 797 + 798 +[[**Battery Info & Power Consumption Analyze**>>http://wiki.dragino.com/xwiki/bin/view/Main/How%20to%20calculate%20the%20battery%20life%20of%20Dragino%20sensors%3F/]] . 799 + 800 + 801 += 5. OTA Firmware update = 802 + 803 + 804 +(% class="wikigeneratedid" %) 805 +User can change firmware SW3L-LB to: 806 + 807 +* Change Frequency band/ region. 808 + 809 +* Update with new features. 810 + 811 +* Fix bugs. 812 + 813 +Firmware and changelog can be downloaded from : **[[Firmware download link>>url:https://www.dropbox.com/sh/kwqv57tp6pejias/AAAopYMATh1GM6fZ-VRCLrpDa?dl=0]]** 814 + 815 +Methods to Update Firmware: 816 + 817 +* (Recommanded way) OTA firmware update via wireless: [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/Firmware%20OTA%20Update%20for%20Sensors/>>url:http://wiki.dragino.com/xwiki/bin/view/Main/Firmware%20OTA%20Update%20for%20Sensors/]] 818 + 819 +* Update through UART TTL interface. **[[Instruction>>url:http://wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H1.LoRaSTv4baseHardware]]**. 820 + 821 += 6. FAQ = 822 + 823 +== 6.1 AT Commands input doesn't work == 824 + 825 + 826 +In the case if user can see the console output but can't type input to the device. Please check if you already include the (% style="color:green" %)**ENTER**(%%) while sending out the command. Some serial tool doesn't send (% style="color:green" %)**ENTER**(%%) while press the send key, user need to add ENTER in their string. 827 + 828 + 829 += 7. Order Info = 830 + 831 + 832 +Part Number: (% style="color:blue" %)**SW3L-LB-XXX-YYY** 833 + 834 +(% style="color:red" %)**XXX**(%%): The default frequency band 835 + 710 710 * (% style="color:red" %)**AS923**(%%): LoRaWAN AS923 band 711 711 712 712 * (% style="color:red" %)**AU915**(%%): LoRaWAN AU915 band ... ... @@ -723,14 +723,43 @@ 723 723 724 724 * (% style="color:red" %)**CN470**(%%): LoRaWAN CN470 band 725 725 852 +((( 853 +(% style="color:blue" %)**YYY**(%%): Flow Sensor Model: 854 +))) 726 726 856 +((( 857 + **004:** DW-004 Flow Sensor: diameter: G1/2” / DN15. 450 pulse = 1 L 858 +))) 727 727 728 -= 9. Packing Info = 860 +((( 861 + **006:** DW-006 Flow Sensor: diameter: G3/4” / DN20. 390 pulse = 1 L 862 +))) 729 729 864 +((( 865 + **010:** DW-010 Flow Sensor: diameter: G 1” / DN25. 64 pulse = 1 L 866 +))) 730 730 868 +* ((( 869 +calculate flag=0: for SW3L-004 Flow Sensor: 450 pulse = 1 L 870 +))) 871 + 872 +* ((( 873 +calculate flag=1: for SW3L-006 Flow Sensor: 390 pulse = 1 L 874 +))) 875 + 876 +* ((( 877 +calculate flag=2: for SW3L-010 Flow Sensor: 64 pulse = 1 L 878 + 879 + 880 + 881 +))) 882 + 883 += 8. Packing Info = 884 + 885 + 731 731 (% style="color:#037691" %)**Package Includes**: 732 732 733 -* DDS75-LB LoRaWANDistance DetectionSensorx 1888 +* SW3L-LB LoRaWAN Flow Sensor 734 734 735 735 (% style="color:#037691" %)**Dimension and weight**: 736 736 ... ... @@ -742,11 +742,9 @@ 742 742 743 743 * Weight / pcs : g 744 744 900 += 9. Support = 745 745 746 746 747 -= 10. Support = 748 - 749 - 750 750 * Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule. 751 751 752 752 * Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[Support@dragino.cc>>mailto:Support@dragino.cc]].