Changes for page DS20L -- LoRaWAN Smart Distance Detector User Manual 01
Last modified by Mengting Qiu on 2023/12/14 11:15
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -22,13 +22,13 @@ 22 22 23 23 It detects the distance(% style="color:blue" %)** between the measured object and the sensor**(%%), and uploads the value via wireless to LoRaWAN IoT Server. 24 24 25 -The LoRa wireless technology used in DDS75-LB allows device to send data and reach extremely long ranges at low data-rates. It provides ultra-long range spread spectrum communication and high interference immunity whilst minimizing current consumption.25 +The LoRa wireless technology used in SW3L-LB allows device to send data and reach extremely long ranges at low data-rates. It provides ultra-long range spread spectrum communication and high interference immunity whilst minimizing current consumption. 26 26 27 - DDS75-LB (% style="color:blue" %)**supports BLE configure**(%%) and (% style="color:blue" %)**wireless OTA update**(%%) which make user easy to use.27 +SW3L-LB (% style="color:blue" %)**supports BLE configure**(%%) and (% style="color:blue" %)**wireless OTA update**(%%) which make user easy to use. 28 28 29 - DDS75-LB is powered by (% style="color:blue" %)**8500mAh Li-SOCI2 battery**(%%), it is designed for long term use up to 5 years.29 +SW3L-LB is powered by (% style="color:blue" %)**8500mAh Li-SOCI2 battery**(%%), it is designed for long term use up to 5 years. 30 30 31 -Each DDS75-LB is pre-load with a set of unique keys for LoRaWAN registrations, register these keys to local LoRaWAN server and it will auto connect after power on.31 +Each SW3L-LB is pre-load with a set of unique keys for LoRaWAN registrations, register these keys to local LoRaWAN server and it will auto connect after power on. 32 32 33 33 [[image:image-20230612170943-2.png||height="525" width="912"]] 34 34 ... ... @@ -105,6 +105,7 @@ 105 105 * Sleep Mode: 5uA @ 3.3v 106 106 * LoRa Transmit Mode: 125mA @ 20dBm, 82mA @ 14dBm 107 107 108 + 108 108 == 1.4 Effective measurement range Reference beam pattern == 109 109 110 110 ... ... @@ -139,7 +139,7 @@ 139 139 (% style="color:blue" %)**Working Mode:** (%%)In this mode, Sensor will work as LoRaWAN Sensor to Join LoRaWAN network and send out sensor data to server. Between each sampling/tx/rx periodically, sensor will be in IDLE mode), in IDLE mode, sensor has the same power consumption as Deep Sleep mode. 140 140 141 141 142 -== 1. 7Button & LEDs ==143 +== 1.6 Button & LEDs == 143 143 144 144 145 145 [[image:Main.User Manual for LoRaWAN End Nodes.D20-LBD22-LBD23-LB_LoRaWAN_Temperature_Sensor_User_Manual.WebHome@1675071855856-879.png]] ... ... @@ -158,10 +158,10 @@ 158 158 ))) 159 159 |(% style="width:167px" %)Fast press ACT 5 times.|(% style="width:117px" %)Deactivate Device|(% style="width:225px" %)(% style="color:red" %)**Red led**(%%) will solid on for 5 seconds. Means device is in Deep Sleep Mode. 160 160 161 -== 1. 8BLE connection ==162 +== 1.7 BLE connection == 162 162 163 163 164 - DDS75-LB support BLE remote configure.165 +SW3L-LB support BLE remote configure. 165 165 166 166 167 167 BLE can be used to configure the parameter of sensor or see the console output from sensor. BLE will be only activate on below case: ... ... @@ -173,13 +173,24 @@ 173 173 If there is no activity connection on BLE in 60 seconds, sensor will shut down BLE module to enter low power mode. 174 174 175 175 176 -== 1. 9Pin Definitions ==177 +== 1.8 Pin Definitions == 177 177 178 178 [[image:image-20230523174230-1.png]] 179 179 180 180 182 +== 1.9 Flow Sensor Spec == 181 181 182 182 185 +((( 186 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:510px" %) 187 +|=(% style="width: 80px;background-color:#D9E2F3;color:#0070C0" %)**Model**|=(% style="width: 80px;background-color:#D9E2F3;color:#0070C0" %)**Probe**|=(% style="width: 80px;background-color:#D9E2F3;color:#0070C0" %)**Diameter**|=(% style="width: 80px;background-color:#D9E2F3;color:#0070C0" %)**Range**|=(% style="width: 80px;background-color:#D9E2F3;color:#0070C0" %)**Max Pressure**|=(% style="width: 110px;background-color:#D9E2F3;color:#0070C0" %)**Measure** 188 +|(% style="width:88px" %)SW3L-004|(% style="width:75px" %)DW-004|(% style="width:107px" %)G1/2" /DN15|(% style="width:101px" %)1~~30L/min|(% style="width:116px" %)≤ 2.0Mpa|(% style="width:124px" %)450 pulse = 1 L 189 +|(% style="width:88px" %)SW3L-006|(% style="width:75px" %)DW-006|(% style="width:107px" %)G3/4" /DN20|(% style="width:101px" %)1~~60L/min|(% style="width:116px" %)≤ 1.2Mpa|(% style="width:124px" %)390 pulse = 1 L 190 +|(% style="width:88px" %)SW3L-010|(% style="width:75px" %)DW-010|(% style="width:107px" %)G 1" /DN25|(% style="width:101px" %)2~~100L/min|(% style="width:116px" %)≤ 2.0Mpa|(% style="width:124px" %)64 pulse = 1 L 191 +))) 192 + 193 + 194 + 183 183 == 2.10 Mechanical == 184 184 185 185 ... ... @@ -192,24 +192,27 @@ 192 192 [[image:Main.User Manual for LoRaWAN End Nodes.D20-LBD22-LBD23-LB_LoRaWAN_Temperature_Sensor_User_Manual.WebHome@1675143909447-639.png]] 193 193 194 194 195 - **ProbeMechanical:**207 +(% style="color:blue" %)**DW-004 Flow Sensor: diameter: G1/2” / DN15. 450 pulse = 1 L** 196 196 209 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/SW3L%20LoRaWAN%20Outdoor%20Flow%20Sensor/WebHome/image-20220519091350-1.png?width=722&height=385&rev=1.1||alt="image-20220519091350-1.png"]] 197 197 198 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDDS75%20-%20LoRaWAN%20Distance%20Detection%20Sensor%20User%20Manual/WebHome/image-20220610172003-1.png?rev=1.1||alt="image-20220610172003-1.png"]] 199 199 212 +(% style="color:blue" %)**006: DW-006 Flow Sensor: diameter: G3/4” / DN20. 390 pulse = 1 L** 200 200 201 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/ LDDS75%20-%20LoRaWAN%20Distance%20Detection%20Sensor%20User%20Manual/WebHome/image-20220610172003-2.png?rev=1.1||alt="image-20220610172003-2.png"]]214 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/SW3L%20LoRaWAN%20Outdoor%20Flow%20Sensor/WebHome/image-20220519091423-2.png?width=723&height=258&rev=1.1||alt="image-20220519091423-2.png"]] 202 202 203 203 204 - [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDDS75%20-%20LoRaWAN%20Distance%20Detection%20Sensor%20User%20Manual/WebHome/image-20220610172003-2.png?rev=1.1||alt="image-20220610172003-2.png"]]217 +(% style="color:blue" %)**010: DW-010 Flow Sensor: diameter: G 1” / DN25. 64 pulse = 1 L** 205 205 219 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/SW3L%20LoRaWAN%20Outdoor%20Flow%20Sensor/WebHome/image-20220519091423-3.png?width=724&height=448&rev=1.1||alt="image-20220519091423-3.png"]] 206 206 207 -= 2. Configure DDS75-LB to connect to LoRaWAN network = 208 208 222 += 2. Configure SW3L-LB to connect to LoRaWAN network = 223 + 209 209 == 2.1 How it works == 210 210 211 211 212 -The DDS75-LB is configured as (% style="color:#037691" %)**LoRaWAN OTAA Class A**(%%) mode by default. It has OTAA keys to join LoRaWAN network. To connect a local LoRaWAN network, you need to input the OTAA keys in the LoRaWAN IoT server and press the button to activate theDDS75-LB. It will automatically join the network via OTAA and start to send the sensor value. The default uplink interval is 20 minutes.227 +The SW3L-LB is configured as (% style="color:#037691" %)**LoRaWAN OTAA Class A**(%%) mode by default. It has OTAA keys to join LoRaWAN network. To connect a local LoRaWAN network, you need to input the OTAA keys in the LoRaWAN IoT server and press the button to activate the SW3L-LB. It will automatically join the network via OTAA and start to send the sensor value. The default uplink interval is 20 minutes. 213 213 214 214 (% style="display:none" %) (%%) 215 215 ... ... @@ -223,9 +223,9 @@ 223 223 [[image:image-20230612171032-3.png||height="492" width="855"]](% style="display:none" %) 224 224 225 225 226 -(% style="color:blue" %)**Step 1:**(%%) Create a device in TTN with the OTAA keys from DDS75-LB.241 +(% style="color:blue" %)**Step 1:**(%%) Create a device in TTN with the OTAA keys from SW3L-LB. 227 227 228 -Each DDS75-LB is shipped with a sticker with the default device EUI as below:243 +Each SW3L-LB is shipped with a sticker with the default device EUI as below: 229 229 230 230 [[image:image-20230426084152-1.png||alt="图片-20230426084152-1.png" height="233" width="502"]] 231 231 ... ... @@ -254,10 +254,10 @@ 254 254 [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LSN50v2-S31-S31B%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20User%20Manual/WebHome/image-20220611161308-6.png?width=744&height=485&rev=1.1||alt="图片-20220611161308-6.png"]] 255 255 256 256 257 -(% style="color:blue" %)**Step 2:**(%%) Activate on DDS75-LB272 +(% style="color:blue" %)**Step 2:**(%%) Activate on SW3L-LB 258 258 259 259 260 -Press the button for 5 seconds to activate the DDS75-LB.275 +Press the button for 5 seconds to activate the SW3L-LB. 261 261 262 262 (% style="color:green" %)**Green led**(%%) will fast blink 5 times, device will enter (% style="color:blue" %)**OTA mode**(%%) for 3 seconds. And then start to JOIN LoRaWAN network. (% style="color:green" %)**Green led**(%%) will solidly turn on for 5 seconds after joined in network. 263 263 ... ... @@ -264,174 +264,355 @@ 264 264 After join success, it will start to upload messages to TTN and you can see the messages in the panel. 265 265 266 266 267 -== 2.3 282 +== 2.3 Uplink Payload == 268 268 284 +=== 2.3.1 Device Status, FPORT~=5 === 269 269 270 -((( 271 -DDS75-LB will uplink payload via LoRaWAN with below payload format: 272 -))) 273 273 274 -((( 275 -Uplink payload includes in total 4 bytes. 276 -Payload for firmware version v1.1.4. . Before v1.1.3, there is on two fields: BAT and Distance 277 -))) 287 +Include device configure status. Once SW3L-LB Joined the network, it will uplink this message to the server. After that, SW3L-LB will uplink Device Status every 12 hours. 278 278 289 +Users can use the downlink command(**0x26 01**) to ask SW3L-LB to send device configure detail, include device configure status. SW3L-LB will uplink a payload via FPort=5 to server. 279 279 291 +The Payload format is as below. 280 280 281 -(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:510px" %) 282 -|=(% style="width: 62.5px;background-color:#D9E2F3;color:#0070C0" %)((( 283 -**Size(bytes)** 284 -)))|=(% style="width: 62.5px;background-color:#D9E2F3;color:#0070C0" %)**2**|=(% style="background-color:#D9E2F3;color:#0070C0" %)**2**|=(% style="background-color:#D9E2F3;color:#0070C0" %)1|=(% style="background-color:#D9E2F3;color:#0070C0" %)2|=(% style="background-color:#D9E2F3;color:#0070C0" %)**1** 285 -|(% style="width:62.5px" %)**Value**|(% style="width:62.5px" %)[[BAT>>||anchor="H2.3.1A0BatteryInfo"]]|((( 286 -[[Distance>>||anchor="H2.3.2A0Distance"]] 287 -(unit: mm) 288 -)))|[[Digital Interrupt (Optional)>>||anchor="H2.3.3A0InterruptPin"]]|((( 289 -[[Temperature (Optional )>>||anchor="H2.3.4A0DS18B20Temperaturesensor"]] 290 -)))|[[Sensor Flag>>||anchor="H2.3.5A0SensorFlag"]] 291 291 292 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDDS75%20-%20LoRaWAN%20Distance%20Detection%20Sensor%20User%20Manual/WebHome/1654850511545-399.png?rev=1.1||alt="1654850511545-399.png"]] 294 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %) 295 +|(% colspan="6" style="background-color:#d9e2f3; color:#0070c0" %)**Device Status (FPORT=5)** 296 +|(% style="width:103px" %)**Size (bytes)**|(% style="width:72px" %)**1**|**2**|(% style="width:91px" %)**1**|(% style="width:86px" %)**1**|(% style="width:44px" %)**2** 297 +|(% style="width:103px" %)**Value**|(% style="width:72px" %)Sensor Model|Firmware Version|(% style="width:91px" %)Frequency Band|(% style="width:86px" %)Sub-band|(% style="width:44px" %)BAT 293 293 299 +Example parse in TTNv3 294 294 295 - === 2.3.1 Battery Info301 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/SW3L%20LoRaWAN%20Outdoor%20Flow%20Sensor/WebHome/1652925144491-755.png?width=732&height=139&rev=1.1||alt="1652925144491-755.png"]] 296 296 297 297 298 - CheckthebatteryvoltageforDDS75-LB.304 +(% style="color:#037691" %)**Sensor Model**(%%): For SW3L-LB, this value is 0x11 299 299 306 +(% style="color:#037691" %)**Firmware Version**(%%): 0x0100, Means: v1.0.0 version 307 + 308 +(% style="color:#037691" %)**Frequency Band**: 309 + 310 +*0x01: EU868 311 + 312 +*0x02: US915 313 + 314 +*0x03: IN865 315 + 316 +*0x04: AU915 317 + 318 +*0x05: KZ865 319 + 320 +*0x06: RU864 321 + 322 +*0x07: AS923 323 + 324 +*0x08: AS923-1 325 + 326 +*0x09: AS923-2 327 + 328 +*0x0a: AS923-3 329 + 330 +*0x0b: CN470 331 + 332 +*0x0c: EU433 333 + 334 +*0x0d: KR920 335 + 336 +*0x0e: MA869 337 + 338 + 339 +(% style="color:#037691" %)**Sub-Band**: 340 + 341 +AU915 and US915:value 0x00 ~~ 0x08 342 + 343 +CN470: value 0x0B ~~ 0x0C 344 + 345 +Other Bands: Always 0x00 346 + 347 + 348 +(% style="color:#037691" %)**Battery Info**: 349 + 350 +Check the battery voltage. 351 + 300 300 Ex1: 0x0B45 = 2885mV 301 301 302 302 Ex2: 0x0B49 = 2889mV 303 303 304 304 305 -=== 2.3.2 Distance===357 +=== 2.3.2 Sensor Configuration, FPORT~=4 === 306 306 307 307 360 +SW3L-LB will only send this command after getting the downlink command (0x26 02) from the server. 361 + 362 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:510px" %) 363 +|(% style="background-color:#d9e2f3; color:#0070c0; width:70px" %) **Size(bytes)**|(% style="background-color:#d9e2f3; color:#0070c0; width:105px" %)**3**|(% style="background-color:#d9e2f3; color:#0070c0; width:60px" %)**1**|(% style="background-color:#d9e2f3; color:#0070c0; width:96px" %)**1**|(% style="background-color:#d9e2f3; color:#0070c0; width:105px" %)**2**|(% style="background-color:#d9e2f3; color:#0070c0; width:74px" %)**1** 364 +|**Value**|(% style="width:104px" %)TDC(unit:sec)|(% style="width:43px" %)N/A|(% style="width:91px" %)Stop Timer|(% style="width:100px" %)Alarm Timer|(% style="width:69px" %)Reserve 365 + 366 +* (% style="color:#037691" %)**TDC: (default: 0x0004B0)** 367 + 368 +Uplink interval for the total pulse count, default value is 0x0004B0 which is 1200 seconds = 20 minutes. 369 + 370 + 371 +* (% style="color:#037691" %)**STOP Duration & Alarm Timer** 372 + 373 +Shows the configure value of [[Alarm for continuously water flow>>||anchor="H3.3.4Alarmforcontinuouslywaterflow"]] 374 + 375 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/SW3L%20LoRaWAN%20Outdoor%20Flow%20Sensor/WebHome/image-20220519095747-2.png?width=723&height=113&rev=1.1||alt="image-20220519095747-2.png"]] 376 + 377 + 378 +=== 2.3.3 Water Flow Value, Uplink FPORT~=2 === 379 + 380 + 308 308 ((( 309 - Getthe distance.Flat objectrange280mm-7500mm.382 +SW3L-LB will send this uplink **after** Device Status once join the LoRaWAN network successfully. And SW3L-LB will: 310 310 ))) 311 311 312 312 ((( 313 -For example, if the data you get from the register is 0x0B 0x05, the distance between the sensor and the measured object is(% style="color:#4472c4" %)** ** 386 +periodically send this uplink every 20 minutes, this interval [[can be changed>>||anchor="H3.3.1SetTransmitIntervalTime"]]. 387 +))) 314 314 315 -(% style="color:#4472c4" %)**0B05(H) = 2821 (D) = 2821 mm.** 389 +((( 390 +Uplink Payload totals 11 bytes. 316 316 ))) 317 317 393 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:510px" %) 394 +|=(% colspan="6" style="width: 510px;background-color:#D9E2F3;color:#0070C0" %)**Water Flow Value, FPORT=2** 395 +|(% style="width:60px" %)**Size(bytes)**|(% style="width:130px" %)**1**|(% style="width:130px" %)**4**|(% style="width:30px" %)**1**|(% style="width:50px" %)**1**|(% style="width:80px" %)**4** 396 +|(% style="width:110px" %)**Value**|(% style="width:81px" %)Calculate Flag & [[Alarm>>||anchor="H3.3.4Alarmforcontinuouslywaterflow"]]|(% style="width:95px" %)((( 397 +Total pulse Or Last Pulse 398 +)))|(% style="width:55px" %)MOD|(% style="width:115px" %)Reserve(0x01)|(% style="width:129px" %)[[Unix TimeStamp>>||anchor="H2.5.2UnixTimeStamp"]] 318 318 319 -* If the sensor value is 0x0000, it means system doesn't detect ultrasonic sensor. 320 -* If the sensor value lower than 0x0118 (280mm), the sensor value will be invalid. Since v1.1.4, all value lower than 280mm will be set to 0x0014(20mm) which means the value is invalid. 400 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:470px" %) 401 +|=(% colspan="4" style="width: 470px;background-color:#D9E2F3;color:#0070C0" %)**Status & Alarm field** 402 +|(% style="width:60px" %)**Size(bit)**|(% style="width:80px" %)**6**|(% style="width:310px" %)**1**|(% style="width:20px" %)**1** 403 +|(% style="width:88px" %)**Value**|(% style="width:117px" %)Calculate Flag|(% style="width:221px" %)Alarm: 0: No Alarm; 1: Alarm|(% style="width:64px" %)N/A 321 321 322 - === 2.3.3 InterruptPin405 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/SW3L%20LoRaWAN%20Outdoor%20Flow%20Sensor/WebHome/image-20220519095946-3.png?width=736&height=284&rev=1.1||alt="image-20220519095946-3.png"]] 323 323 324 324 325 -This data field shows if this packet is generated by interrupt or not. [[Click here>>||anchor="H3.3A0SetInterruptMode"]] for the hardware and software set up. 408 +* ((( 409 +(% style="color:#037691" %)**Calculate Flag** 410 +))) 326 326 327 -**Example:** 412 +((( 413 +The calculate flag is a user defined field, IoT server can use this flag to handle different meters with different pulse factors. For example, if there are 100 Flow Sensors, meters 1 ~~50 are 1 liter/pulse and meters 51 ~~ 100 has 1.5 liter/pulse. 414 +))) 328 328 329 -0x00: Normal uplink packet. 416 +((( 417 +**Example: in the default payload:** 418 +))) 330 330 331 -0x01: Interrupt Uplink Packet. 420 +* ((( 421 +calculate flag=0: for SW3L-004 Flow Sensor: 450 pulse = 1 L 422 +))) 423 +* ((( 424 +calculate flag=1: for SW3L-006 Flow Sensor: 390 pulse = 1 L 425 +))) 426 +* ((( 427 +calculate flag=2: for SW3L-010 Flow Sensor: 64 pulse = 1 L 428 +))) 332 332 430 +((( 431 +Default value: 0. 432 +))) 333 333 334 -=== 2.3.4 DS18B20 Temperature sensor === 434 +((( 435 +Range (6 bits): (b)000000 ~~ (b) 111111 335 335 437 +If user use with a meter for example is 0.02L/pulse. To proper decode the correct value in server, 336 336 337 - Thisisoptional, user canconnectexternalDS18B20 sensorto the+3.3v, 1-wireandGNDpin . andthisfield will reporttemperature.439 +1) User can set the Calculate Flag of this sensor to 3. 338 338 339 -**Example**: 441 +2) In server side, when a sensor data arrive, the decoder will check the value of Calculate Flag, It the value is 3, the total volume = 0.02 x Pulse Count. 442 +))) 340 340 341 -If payload is: 0105H: (0105 & FC00 == 0), temp = 0105H /10 = 26.1 degree 444 +((( 445 +(% style="color:red" %)**NOTE: User need to set Calculate Flag to proper value before use Flow Sensor. Downlink or AT Command see: **(%%)Refer: [[Set Calculate Flag>>||anchor="H3.3.6Setthecalculateflag"]] 446 +))) 342 342 343 -If payload is: FF3FH : (FF3F & FC00 == 1) , temp = (FF3FH - 65536)/10 = -19.3 degrees. 448 +* ((( 449 +(% style="color:#037691" %)**Alarm** 450 +))) 344 344 345 -(% style="color:red" %)**Note: DS18B20 feature is supported in the hardware version > v1.3 which made since early of 2021.** 452 +((( 453 +See [[Alarm for continuously water flow>>||anchor="H3.3.4Alarmforcontinuouslywaterflow"]] 454 +))) 346 346 456 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/SW3L%20LoRaWAN%20Outdoor%20Flow%20Sensor/WebHome/image-20220519095946-4.png?width=724&height=65&rev=1.1||alt="image-20220519095946-4.png"]] 347 347 348 -=== 2.3.5 Sensor Flag === 349 349 459 +* ((( 460 +(% style="color:#037691" %)**Total pulse** 461 +))) 350 350 351 351 ((( 352 - 0x01: DetectUltrasonic Sensor464 +Total pulse/counting since factory 353 353 ))) 354 354 355 355 ((( 356 -0x00 :NoUltrasonic Sensor468 +Range (4 Bytes) : 0x00000000~~ 0xFFFFFFFF . 357 357 ))) 358 358 471 +* ((( 472 +(% style="color:#037691" %)**Last Pulse** 473 +))) 359 359 360 -=== 2.3.6 Decode payload in The Things Network === 475 +((( 476 +Total pulse since last FPORT=2 uplink. (Default 20 minutes) 477 +))) 361 361 479 +((( 480 +Range (4 Bytes) : 0x00000000~~ 0xFFFFFFFF . 481 +))) 362 362 363 -While using TTN network, you can add the payload format to decode the payload. 483 +* ((( 484 +(% style="color:#037691" %)**MOD: Default =0** 485 +))) 364 364 365 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDDS75%20-%20LoRaWAN%20Distance%20Detection%20Sensor%20User%20Manual/WebHome/1654850829385-439.png?rev=1.1||alt="1654850829385-439.png"]] 487 +((( 488 +MOD=0 ~-~-> Uplink Total Pulse since factory 489 +))) 366 366 367 -The payload decoder function for TTN V3 is here: 491 +((( 492 +MOD=1 ~-~-> Uplink total pulse since last FPORT=2 uplink. 493 +))) 368 368 495 +* ((( 496 +(% style="color:#037691" %)**Water Flow Value** 497 +))) 498 + 369 369 ((( 370 - DDS75-LBTTNV3 PayloadDecoder: [[ttps:~~/~~/github.com/dragino/dragino-end-node-decoder>>https://github.com/dragino/dragino-end-node-decoder]]500 +**Total Water Flow Volume = (Calculate Flag) x (Total Pulse)=9597/450=21.3L** 371 371 ))) 372 372 503 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/SW3L%20LoRaWAN%20Outdoor%20Flow%20Sensor/WebHome/image-20220519095946-5.png?width=727&height=50&rev=1.1||alt="image-20220519095946-5.png"]] 373 373 374 -== 2.4 Uplink Interval == 375 375 506 +((( 507 +**Total Water Flow for TDC timer = (Calculate Flag) x (Last Pulse)=79/450=0.2L** 508 +))) 376 376 377 - The DDS75-LB by defaultuplinkthe sensor data every 20 minutes.Usercan change this interval by AT Commandr LoRaWAN Downlink Command. See this link: [[Change Uplink Interval>>doc:Main.EndDevice AT CommandsndDownlink Command.WebHome||anchor="H4.1ChangeUplinkInterval"]]510 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/SW3L%20LoRaWAN%20Outdoor%20Flow%20Sensor/WebHome/image-20220519095946-6.png?width=733&height=43&rev=1.1||alt="image-20220519095946-6.png"]] ** ** 378 378 379 379 380 -== 2. 5Show Datain DataCakeIoTServer==513 +=== 2.3.4 Historical Water Flow Status, FPORT~=3 === 381 381 382 382 383 383 ((( 384 - [[DATACAKE>>url:https://datacake.co/]] provides ahumanfriendly interface to show thensordata, oncewe have datain TTN, we canuse [[DATACAKE>>url:https://datacake.co/]] to connecttoTTNandsee the datain DATACAKE. Belowarethe steps:517 +SW3L-LB stores sensor values and users can retrieve these history values via the [[downlink command>>||anchor="H2.5DatalogFeature"]]. 385 385 ))) 386 386 387 387 ((( 388 - 521 +The historical payload includes one or multiplies entries and every entry has the same payload as Real-Time water flow status. 389 389 ))) 390 390 524 +* ((( 525 +Each data entry is 11 bytes and has the same structure as [[real time water flow status>>||anchor="H2.3.3A0WaterFlowValue2CUplinkFPORT3D2"]], to save airtime and battery, SW3L will send max bytes according to the current DR and Frequency bands. 526 +))) 527 + 391 391 ((( 392 - (% style="color:blue"%)**Step1**(%%)**: Besurethat your deviceisprogrammed andproperlyconnectedtothenetworkatthistime.**529 +For example, in the US915 band, the max payload for different DR is: 393 393 ))) 394 394 395 395 ((( 396 -(% style="color:blue" %)** Step2**(%%)**:ToconfiguretheApplicationtoforward data to DATACAKE you willneedto add integration.Toadd the DATACAKE integration, perform the following steps:**533 +(% style="color:blue" %)**a) DR0:**(%%) max is 11 bytes so one entry of data 397 397 ))) 398 398 536 +((( 537 +(% style="color:blue" %)**b) DR1:**(%%) max is 53 bytes so devices will upload 4 entries of data (total 44 bytes) 538 +))) 399 399 400 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDDS75%20-%20LoRaWAN%20Distance%20Detection%20Sensor%20User%20Manual/WebHome/1654592790040-760.png?rev=1.1||alt="1654592790040-760.png"]] 540 +((( 541 +(% style="color:blue" %)**c) DR2:**(%%) total payload includes 11 entries of data 542 +))) 401 401 544 +((( 545 +(% style="color:blue" %)**d) DR3:**(%%) total payload includes 22 entries of data. 546 +))) 402 402 403 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDDS75%20-%20LoRaWAN%20Distance%20Detection%20Sensor%20User%20Manual/WebHome/1654592800389-571.png?rev=1.1||alt="1654592800389-571.png"]] 548 +((( 549 +If SW3L-LB doesn't have any data in the polling time. It will uplink 11 bytes of 0 550 +))) 404 404 552 +((( 553 +(% style="color:#037691" %)**Downlink:** 554 +))) 405 405 406 -(% style="color:blue" %)**Step 3**(%%)**: Create an account or log in Datacake.** 556 +((( 557 +0x31 62 46 B1 F0 62 46 B3 94 07 558 +))) 407 407 408 - (% style="color:blue"%)**Step 4**(%%)**:Search theDDS75-LB andadd DevEUI.**560 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/SW3L%20LoRaWAN%20Outdoor%20Flow%20Sensor/WebHome/1652926690850-712.png?width=726&height=115&rev=1.1||alt="1652926690850-712.png"]] 409 409 410 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDDS75%20-%20LoRaWAN%20Distance%20Detection%20Sensor%20User%20Manual/WebHome/1654851029373-510.png?rev=1.1||alt="1654851029373-510.png"]] 411 411 563 +((( 564 +(% style="color:#037691" %)**Uplink:** 565 +))) 412 412 413 -After added, the sensor data arrive TTN V3, it will also arrive and show in Datacake. 567 +((( 568 +00 00 01 00 00 00 00 62 46 B2 26 00 00 01 00 00 00 00 62 46 B2 5D 00 00 01 00 00 00 00 62 46 B2 99 00 00 01 00 00 00 00 62 46 B2 D5 00 00 01 00 00 01 15 62 46 B3 11 00 00 01 00 00 01 1F 62 46 B3 7E 569 +))) 414 414 415 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDDS75%20-%20LoRaWAN%20Distance%20Detection%20Sensor%20User%20Manual/WebHome/image-20220610165129-11.png?width=1088&height=595&rev=1.1||alt="image-20220610165129-11.png"]] 571 +((( 572 +(% style="color:#037691" %)**Parsed Value:** 573 +))) 416 416 575 +((( 576 +[Alarm, Calculate Flag, MOD, Total pulse or Last Pulse,** **Water Flow Value, TIME] 577 +))) 417 417 418 418 419 -== 2.6 Datalog Feature == 580 +((( 581 +[FALSE,0,0,0,0.0,2022-04-01 08:04:54], 582 +))) 420 420 584 +((( 585 +[FALSE,0,0,0,0.0,2022-04-01 08:05:49], 586 +))) 421 421 422 -Datalog Feature is to ensure IoT Server can get all sampling data from Sensor even if the LoRaWAN network is down. For each sampling, DDS75-LB will store the reading for future retrieving purposes. 588 +((( 589 +[FALSE,0,0,0,0.0,2022-04-01 08:06:49], 590 +))) 423 423 592 +((( 593 +[FALSE,0,0,0,0.0,2022-04-01 08:07:49], 594 +))) 424 424 425 -=== 2.6.1 Ways to get datalog via LoRaWAN === 596 +((( 597 +[FALSE,0,0,277,0.6,2022-04-01 08:08:49], 598 +))) 426 426 600 +((( 601 +[FALSE,0,0,287,0.6,2022-04-01 08:10:38], 602 +))) 427 427 428 - SetPNACKMD=1, DDS75-LBwill wait for ACK for every uplink,whenthereisetwork,DDS75-LB will markthese records with non-ack messages andstorethesensor data, and itwill sendall messages (10sinterval) after the network recovery.604 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/SW3L%20LoRaWAN%20Outdoor%20Flow%20Sensor/WebHome/1652926777796-267.png?width=724&height=279&rev=1.1||alt="1652926777796-267.png"]] 429 429 606 + 607 +== 2.4 Payload Decoder file == 608 + 609 + 610 +In TTN, use can add a custom payload so it shows friendly reading 611 + 612 +In the page (% style="color:#037691" %)**Applications ~-~-> Payload Formats ~-~-> Custom ~-~-> decoder**(%%) to add the decoder from: [[https:~~/~~/github.com/dragino/dragino-end-node-decoder>>https://github.com/dragino/dragino-end-node-decoder]] 613 + 614 + 615 +== 2.5 Datalog Feature == 616 + 617 + 618 +Datalog Feature is to ensure IoT Server can get all sampling data from Sensor even if the LoRaWAN network is down. For each sampling, SW3L-LB will store the reading for future retrieving purposes. 619 + 620 + 621 +=== 2.5.1 Ways to get datalog via LoRaWAN === 622 + 623 + 624 +Set PNACKMD=1, SW3L-LB will wait for ACK for every uplink, when there is no LoRaWAN network,SW3L-LB will mark these records with non-ack messages and store the sensor data, and it will send all messages (10s interval) after the network recovery. 625 + 430 430 * ((( 431 -a) DDS75-LB will do an ACK check for data records sending to make sure every data arrive server.627 +a) SW3L-LB will do an ACK check for data records sending to make sure every data arrive server. 432 432 ))) 433 433 * ((( 434 -b) DDS75-LB will send data in **CONFIRMED Mode** when PNACKMD=1, butDDS75-LB won't re-transmit the packet if it doesn't get ACK, it will just mark it as a NONE-ACK message. In a future uplink ifDDS75-LB gets a ACK,DDS75-LB will consider there is a network connection and resend all NONE-ACK messages.630 +b) SW3L-LB will send data in **CONFIRMED Mode** when PNACKMD=1, but SW3L-LB won't re-transmit the packet if it doesn't get ACK, it will just mark it as a NONE-ACK message. In a future uplink if SW3L-LB gets a ACK, SW3L-LB will consider there is a network connection and resend all NONE-ACK messages. 435 435 ))) 436 436 437 437 Below is the typical case for the auto-update datalog feature (Set PNACKMD=1) ... ... @@ -439,10 +439,10 @@ 439 439 [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/WebHome/image-20220703111700-2.png?width=1119&height=381&rev=1.1||alt="图片-20220703111700-2.png" height="381" width="1119"]] 440 440 441 441 442 -=== 2. 6.2 Unix TimeStamp ===638 +=== 2.5.2 Unix TimeStamp === 443 443 444 444 445 - DDS75-LB uses Unix TimeStamp format based on641 +SW3L-LB uses Unix TimeStamp format based on 446 446 447 447 [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/WebHome/image-20220523001219-11.png?width=627&height=97&rev=1.1||alt="图片-20220523001219-11.png" height="97" width="627"]] 448 448 ... ... @@ -456,17 +456,17 @@ 456 456 So, we can use AT+TIMESTAMP=1611889405 or downlink 3060137afd00 to set the current time 2021 – Jan ~-~- 29 Friday 03:03:25 457 457 458 458 459 -=== 2. 6.3 Set Device Time ===655 +=== 2.5.3 Set Device Time === 460 460 461 461 462 462 User need to set (% style="color:blue" %)**SYNCMOD=1**(%%) to enable sync time via MAC command. 463 463 464 -Once DDS75-LB Joined LoRaWAN network, it will send the MAC command (DeviceTimeReq) and the server will reply with (DeviceTimeAns) to send the current time toDDS75-LB. IfDDS75-LB fails to get the time from the server,DDS75-LB will use the internal time and wait for next time request (AT+SYNCTDC to set the time request period, default is 10 days).660 +Once SW3L-LB Joined LoRaWAN network, it will send the MAC command (DeviceTimeReq) and the server will reply with (DeviceTimeAns) to send the current time to SW3L-LB. If SW3L-LB fails to get the time from the server, SW3L-LB will use the internal time and wait for next time request (AT+SYNCTDC to set the time request period, default is 10 days). 465 465 466 466 (% style="color:red" %)**Note: LoRaWAN Server need to support LoRaWAN v1.0.3(MAC v1.0.3) or higher to support this MAC command feature, Chirpstack,TTN V3 v3 and loriot support but TTN V3 v2 doesn't support. If server doesn't support this command, it will through away uplink packet with this command, so user will lose the packet with time request for TTN V3 v2 if SYNCMOD=1.** 467 467 468 468 469 -=== 2. 6.4 Poll sensor value ===665 +=== 2.5.4 Poll sensor value === 470 470 471 471 472 472 Users can poll sensor values based on timestamps. Below is the downlink command. ... ... @@ -489,24 +489,24 @@ 489 489 ))) 490 490 491 491 ((( 492 -Uplink Internal =5s,means DDS75-LB will send one packet every 5s. range 5~~255s.688 +Uplink Internal =5s,means SW3L-LB will send one packet every 5s. range 5~~255s. 493 493 ))) 494 494 495 495 496 -== 2. 7Frequency Plans ==692 +== 2.6 Frequency Plans == 497 497 498 498 499 -The DDS75-LB uses OTAA mode and below frequency plans by default. If user want to use it with different frequency plan, please refer the AT command sets.695 +The SW3L-LB uses OTAA mode and below frequency plans by default. If user want to use it with different frequency plan, please refer the AT command sets. 500 500 501 501 [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20Frequency%20Band/>>http://wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20Frequency%20Band/]] 502 502 503 503 504 -= 3. Configure DDS75-LB =700 += 3. Configure SW3L-LB = 505 505 506 506 == 3.1 Configure Methods == 507 507 508 508 509 - DDS75-LB supports below configure method:705 +SW3L-LB supports below configure method: 510 510 511 511 * AT Command via Bluetooth Connection (**Recommended**): [[BLE Configure Instruction>>http://wiki.dragino.com/xwiki/bin/view/Main/BLE%20Bluetooth%20Remote%20Configure/]]. 512 512 ... ... @@ -528,10 +528,10 @@ 528 528 [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/>>http://wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/]] 529 529 530 530 531 -== 3.3 Commands special design for DDS75-LB ==727 +== 3.3 Commands special design for SW3L-LB == 532 532 533 533 534 -These commands only valid for DDS75-LB, as below:730 +These commands only valid for SW3L-LB, as below: 535 535 536 536 537 537 === 3.3.1 Set Transmit Interval Time === ... ... @@ -576,135 +576,259 @@ 576 576 Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds 577 577 ))) 578 578 579 -=== 3.3.2 Set InterruptMode===775 +=== 3.3.2 Quit AT Command === 580 580 581 581 582 -Feature ,SetInterruptmodeforPA8of pin.778 +Feature: Quit AT Command mode, so user needs to input the password again before using AT Commands. 583 583 584 - WhenAT+INTMOD=0 isset, PA8 isusedasaigitalinput port.780 +(% style="color:blue" %)**AT Command: AT+DISAT** 585 585 586 -(% style="color:blue" %)**AT Command: AT+INTMOD** 782 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:452px" %) 783 +|=(% style="width: 155px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 198px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 99px;background-color:#D9E2F3;color:#0070C0" %)**Response** 784 +|(% style="width:155px" %)AT+DISAT|(% style="width:198px" %)Quit AT Commands mode|(% style="width:96px" %)OK 587 587 588 -(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %) 589 -|=(% style="width: 155px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 197px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 158px;background-color:#D9E2F3;color:#0070C0" %)**Response** 590 -|(% style="width:154px" %)AT+INTMOD=?|(% style="width:196px" %)Show current interrupt mode|(% style="width:157px" %)((( 591 -0 592 -OK 593 -the mode is 0 =Disable Interrupt 786 +(% style="color:blue" %)**Downlink Command:** 787 + 788 +No downlink command for this feature. 789 + 790 + 791 +=== 3.3.3 Get Device Status === 792 + 793 + 794 +Send a LoRaWAN downlink to ask device send Alarm settings. 795 + 796 +(% style="color:blue" %)**Downlink Payload: **(%%)0x26 01 797 + 798 +Sensor will upload Device Status via FPORT=5. See payload section for detail. 799 + 800 + 801 +=== 3.3.4 Alarm for continuously water flow === 802 + 803 + 804 +((( 805 +This feature is to monitor and send Alarm for continuously water flow. 594 594 ))) 595 -|(% style="width:154px" %)AT+INTMOD=2|(% style="width:196px" %)((( 596 -Set Transmit Interval 597 -0. (Disable Interrupt), 598 -~1. (Trigger by rising and falling edge) 599 -2. (Trigger by falling edge) 600 -3. (Trigger by rising edge) 601 -)))|(% style="width:157px" %)OK 602 602 603 -(% style="color:blue" %)**Downlink Command: 0x06** 808 +((( 809 +Example case is for Toilet water monitoring, if some one push toilet button, the toilet will have water flow. If the toilet button has broken and can't returned to original state, the water flow will keep for hours or days which cause huge waste for water. 810 +))) 604 604 605 -Format: Command Code (0x06) followed by 3 bytes. 812 +((( 813 +To monitor this faulty and send alarm, there are two settings: 814 +))) 606 606 607 -This means that the interrupt mode of the end node is set to 0x000003=3 (rising edge trigger), and the type code is 06. 816 +* ((( 817 +(% style="color:#4f81bd" %)**Stop Duration: Unit: Second** 818 +))) 608 608 609 -* Example 1: Downlink Payload: 06000000 ~/~/ Turn off interrupt mode 820 +((( 821 +Default: 15s, If SW3L-LB didn't see any water flow in 15s, SW3L-LB will consider stop of water flow event. 822 +))) 610 610 611 -* Example 2: Downlink Payload: 06000003 ~/~/ Set the interrupt mode to rising edge trigger 824 +* ((( 825 +(% style="color:#4f81bd" %)**Alarm Timer: Units: Minute; Default 0 minutes (means Alarm disable)** 826 +))) 612 612 613 -= 4. Battery & Power Consumption = 828 +((( 829 +**Example:** 3 minutes, if SW3L-LB detect a start of water flow event and didn't detect a stop event within Alarm timer, SW3L-LB will send an Alarm to indicate a water flow abnormal alarm. 830 +))) 614 614 832 +((( 833 +So for example, If we set stop duration=15s and Alarm Timer=3minutes. If the toilet water flow continuously for more than 3 minutes, Sensor will send an alarm (in Confirmed MODE) to platform. 834 +))) 615 615 616 -DDS75-LB use ER26500 + SPC1520 battery pack. See below link for detail information about the battery info and how to replace. 836 +((( 837 +(% style="color:red" %)**Note:** **After this alarm is send, sensor will consider a stop of water flow and count for another new event. So if water flow waste last for 1 hour, Sensor will keep sending alarm every 3 minutes.** 838 +))) 617 617 618 -[[**Battery Info & Power Consumption Analyze**>>http://wiki.dragino.com/xwiki/bin/view/Main/How%20to%20calculate%20the%20battery%20life%20of%20Dragino%20sensors%3F/]] . 840 +((( 841 +(% style="color:#4f81bd" %)**AT Command**(%%) to configure: 842 +))) 619 619 844 +* ((( 845 +AT+PTRIG=15,3 ~-~-> Set Stop duration: 15s, Alarm Timer: 3 minutes. 846 +))) 620 620 621 -= 5. OTA Firmware update = 848 +* ((( 849 +AT+ PTRIG=15,0 ~-~-> Default Value, disable water waste Alarm. 850 +))) 622 622 852 +((( 853 +(% style="color:#4f81bd" %)**Downlink Command**(%%) to configure: 854 +))) 623 623 624 -(% class="wikigeneratedid" %) 625 -User can change firmware DDS75-LB to: 856 +((( 857 +Command: **0xAA aa bb cc** 858 +))) 626 626 627 -* Change Frequency band/ region. 860 +((( 861 +AA: Command Type Code 862 +))) 628 628 629 -* Update with new features. 864 +((( 865 +aa: Stop duration 866 +))) 630 630 631 -* Fix bugs. 868 +((( 869 +bb cc: Alarm Timer 870 +))) 632 632 633 -Firmware and changelog can be downloaded from : **[[Firmware download link>>url:https://www.dropbox.com/sh/7la95mae0fn03xe/AACtzs-32m22TLb75B-iIr-Qa?dl=0]]** 872 +((( 873 +If user send 0xAA 0F 00 03: equal to AT+PTRIG=15,3 874 +))) 634 634 635 -Methods to Update Firmware: 636 636 637 - *(Recommandedway) OTA firmwareupdate via wireless:[[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/Firmware%20OTA%20Update%20for%20Sensors/>>url:http://wiki.dragino.com/xwiki/bin/view/Main/Firmware%20OTA%20Update%20for%20Sensors/]]877 +=== 3.3.5 Clear Flash Record === 638 638 639 -* Update through UART TTL interface. **[[Instruction>>url:http://wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H1.LoRaSTv4baseHardware]]**. 640 640 641 - =6.FAQ=880 +Feature: Clear flash storage for data log feature. 642 642 882 +(% style="color:blue" %)**AT Command: AT+CLRDTA** 643 643 644 -== 6.1 What is the frequency plan for DDS75-LB? == 884 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:500px" %) 885 +|=(% style="width: 157px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 169px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 174px;background-color:#D9E2F3;color:#0070C0" %)**Response** 886 +|(% style="width:157px" %)AT+CLRDTA|(% style="width:169px" %)Clear flash storage for data log feature.|Clear all stored sensor data… OK 645 645 888 +((( 889 +(% style="color:blue" %)**Downlink Command:** 890 +))) 646 646 647 -DDS75-LB use the same frequency as other Dragino products. User can see the detail from this link: [[Introduction>>doc:Main.End Device Frequency Band.WebHome||anchor="H1.Introduction"]] 892 +((( 893 +* **Example**: 0xA301 ~/~/ Same as AT+CLRDTA 894 +))) 648 648 649 649 650 -== 6.2 Can I use DDS75-LB in condensation environment? == 651 651 898 +=== 3.3.6 Set the calculate flag === 652 652 653 -DDS75-LB is not suitable to be used in condensation environment. Condensation on the DDS75-LB probe will affect the reading and always got 0. 654 654 901 +Feature: Set the calculate flag 655 655 656 - =7. TroubleShooting=903 +(% style="color:blue" %)**AT Command: AT+CALCFLAG** 657 657 658 -== 7.1 Why I can't join TTN V3 in US915 / AU915 bands? == 905 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:461px" %) 906 +|=(% style="width: 158px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 193px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 110px;background-color:#D9E2F3;color:#0070C0" %)**Response** 907 +|(% style="width:158px" %)AT+CALCFLAG =1|(% style="width:192px" %)Set the calculate flag to 1.|(% style="width:109px" %)OK 908 +|(% style="width:158px" %)AT+CALCFLAG =2|(% style="width:192px" %)Set the calculate flag to 2.|(% style="width:109px" %)OK 659 659 910 +(% style="color:blue" %)**Downlink Command:** 660 660 661 - Itis due to channelmapping. Pleaseseebelowlink:[[Frequencyband>>doc:Main.LoRaWAN Communication Debug.WebHome||anchor="H2.NoticeofUS9152FCN4702FAU915Frequencyband"]]912 +* **Example**: 0XA501 ~/~/ Same as AT+CALCFLAG =1 662 662 914 +=== 3.3.7 Set count number === 663 663 664 -== 7.2 AT Command input doesn't work == 665 665 917 +Feature: Manually set the count number 666 666 667 - In the case if user can see the console output but can't type input to the device. Please check if you already include the(% style="color:blue" %)**ENTER**(%%)while sendingout the command. Some serial tool doesn't send (% style="color:blue"%)**ENTER**(%%) while press the send key, user need to add ENTER in their string.919 +(% style="color:blue" %)**AT Command: AT+SETCNT** 668 668 921 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:479px" %) 922 +|=(% style="width: 160px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 223px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 96px;background-color:#D9E2F3;color:#0070C0" %)**Response** 923 +|(% style="width:160px" %)AT+ SETCNT =0|(% style="width:221px" %)Set the count number to 0.|(% style="width:95px" %)OK 924 +|(% style="width:160px" %)AT+ SETCNT =100|(% style="width:221px" %)Set the count number to 100.|(% style="width:95px" %)OK 669 669 670 - ==7.3 Why doeshesensorreadingshow0or "No sensor" ==926 +(% style="color:blue" %)**Downlink Command:** 671 671 928 +* **Example**: 0xA6000001 ~/~/ Same as AT+ SETCNT =1 672 672 673 - ~1.The measurementobjectisveryclosetothesensor,but in the blindspotofthesensor.930 +* **Example**: 0xA6000064 ~/~/ Same as AT+ SETCNT =100 674 674 675 - 2. Sensorwiringis disconnected932 +=== 3.3.8 Set Interrupt Mode === 676 676 677 -3. Not using the correct decoder 678 678 935 +Feature, Set Interrupt mode for PA8 of pin. 679 679 680 - ==5.4AbnormalreadingsThegap betweenmultiplereadingsistoo largeor the gapbetween the readings andtheactualvalueistoolarge ==937 +When AT+INTMOD=0 is set, PA8 is used as a digital input port. 681 681 939 +(% style="color:blue" %)**AT Command: AT+INTMOD** 682 682 683 -1) Please check if there is something on the probe affecting its measurement (condensed water, volatile oil, etc.) 941 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %) 942 +|=(% style="width: 155px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 197px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 158px;background-color:#D9E2F3;color:#0070C0" %)**Response** 943 +|(% style="width:154px" %)AT+INTMOD=?|(% style="width:196px" %)Show current interrupt mode|(% style="width:157px" %)((( 944 +0 945 +OK 946 +the mode is 0 =Disable Interrupt 947 +))) 948 +|(% style="width:154px" %)AT+INTMOD=2|(% style="width:196px" %)((( 949 +Set Transmit Interval 950 +0. (Disable Interrupt), 951 +~1. (Trigger by rising and falling edge) 952 +2. (Trigger by falling edge) 953 +3. (Trigger by rising edge) 954 +)))|(% style="width:157px" %)OK 684 684 685 - 2)Doesitchangewith temperature,temperaturewill affectitsmeasurement956 +(% style="color:blue" %)**Downlink Command: 0x06** 686 686 687 - 3) If abnormal dataoccurs, you canturnon DEBUG mode,Pleaseuse downlinkorATCOMMANtoenter DEBUG mode.958 +Format: Command Code (0x06) followed by 3 bytes. 688 688 689 - downlinkcommand:(%style="color:blue"%)**F101**(%%),AT command:(%style="color:blue"%)**AT+DDEBUG=1**960 +This means that the interrupt mode of the end node is set to 0x000003=3 (rising edge trigger), and the type code is 06. 690 690 691 - 4)After entering the debugmode,itwill send20piecesofdataatatime,andyoucan senditsuplinktous for analysis962 +* Example 1: Downlink Payload: 06000000 ~/~/ Turn off interrupt mode 692 692 693 - [[image:image-20230113135125-2.png||height="136"width="1057"]]964 +* Example 2: Downlink Payload: 06000003 ~/~/ Set the interrupt mode to rising edge trigger 694 694 966 +=== 3.3.9 Set work mode === 695 695 696 -Its original payload will be longer than other data. Even though it is being parsed, it can be seen that it is abnormal data. 697 697 698 - Please sendthedata tous forcheck.969 +Feature: Manually set the work mode 699 699 700 700 701 - =8. OrderInfo=972 +(% style="color:blue" %)**AT Command: AT+MOD** 702 702 974 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:463px" %) 975 +|=(% style="width: 162px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 193px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 108px;background-color:#D9E2F3;color:#0070C0" %)**Response** 976 +|(% style="width:162px" %)AT+MOD=0|(% style="width:191px" %)Set the work mode to 0.|(% style="width:106px" %)OK 977 +|(% style="width:162px" %)AT+MOD=1|(% style="width:191px" %)Set the work mode to 1|(% style="width:106px" %)OK 703 703 704 - Part Number:(% style="color:blue" %)**DDS75-LB-XXX**979 +(% style="color:blue" %)**Downlink Command:** 705 705 706 - (%style="color:red"%)**XXX**(%%):**Thedefaultfrequencyband**981 +* **Example: **0x0A00 ~/~/ Same as AT+MOD=0 707 707 983 +* **Example:** 0x0A01 ~/~/ Same as AT+MOD=1 984 + 985 += 4. Battery & Power Consumption = 986 + 987 + 988 +SW3L-LB use ER26500 + SPC1520 battery pack. See below link for detail information about the battery info and how to replace. 989 + 990 +[[**Battery Info & Power Consumption Analyze**>>http://wiki.dragino.com/xwiki/bin/view/Main/How%20to%20calculate%20the%20battery%20life%20of%20Dragino%20sensors%3F/]] . 991 + 992 + 993 += 5. OTA Firmware update = 994 + 995 + 996 +(% class="wikigeneratedid" %) 997 +User can change firmware SW3L-LB to: 998 + 999 +* Change Frequency band/ region. 1000 + 1001 +* Update with new features. 1002 + 1003 +* Fix bugs. 1004 + 1005 +Firmware and changelog can be downloaded from : **[[Firmware download link>>url:https://www.dropbox.com/sh/kwqv57tp6pejias/AAAopYMATh1GM6fZ-VRCLrpDa?dl=0]]** 1006 + 1007 +Methods to Update Firmware: 1008 + 1009 +* (Recommanded way) OTA firmware update via wireless: [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/Firmware%20OTA%20Update%20for%20Sensors/>>url:http://wiki.dragino.com/xwiki/bin/view/Main/Firmware%20OTA%20Update%20for%20Sensors/]] 1010 + 1011 +* Update through UART TTL interface. **[[Instruction>>url:http://wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H1.LoRaSTv4baseHardware]]**. 1012 + 1013 += 6. FAQ = 1014 + 1015 +== 6.1 AT Commands input doesn't work == 1016 + 1017 + 1018 +In the case if user can see the console output but can't type input to the device. Please check if you already include the (% style="color:green" %)**ENTER**(%%) while sending out the command. Some serial tool doesn't send (% style="color:green" %)**ENTER**(%%) while press the send key, user need to add ENTER in their string. 1019 + 1020 + 1021 += 7. Order Info = 1022 + 1023 + 1024 +Part Number: (% style="color:blue" %)**SW3L-LB-XXX-YYY** 1025 + 1026 +(% style="color:red" %)**XXX**(%%): The default frequency band 1027 + 708 708 * (% style="color:red" %)**AS923**(%%): LoRaWAN AS923 band 709 709 710 710 * (% style="color:red" %)**AU915**(%%): LoRaWAN AU915 band ... ... @@ -721,15 +721,43 @@ 721 721 722 722 * (% style="color:red" %)**CN470**(%%): LoRaWAN CN470 band 723 723 1044 +((( 1045 +(% style="color:blue" %)**YYY**(%%): Flow Sensor Model: 1046 +))) 724 724 1048 +((( 1049 + **004:** DW-004 Flow Sensor: diameter: G1/2” / DN15. 450 pulse = 1 L 1050 +))) 725 725 1052 +((( 1053 + **006:** DW-006 Flow Sensor: diameter: G3/4” / DN20. 390 pulse = 1 L 1054 +))) 726 726 727 -= 9. Packing Info = 1056 +((( 1057 + **010:** DW-010 Flow Sensor: diameter: G 1” / DN25. 64 pulse = 1 L 1058 +))) 728 728 1060 +* ((( 1061 +calculate flag=0: for SW3L-004 Flow Sensor: 450 pulse = 1 L 1062 +))) 729 729 1064 +* ((( 1065 +calculate flag=1: for SW3L-006 Flow Sensor: 390 pulse = 1 L 1066 +))) 1067 + 1068 +* ((( 1069 +calculate flag=2: for SW3L-010 Flow Sensor: 64 pulse = 1 L 1070 + 1071 + 1072 + 1073 +))) 1074 + 1075 += 8. Packing Info = 1076 + 1077 + 730 730 (% style="color:#037691" %)**Package Includes**: 731 731 732 -* DDS75-LB LoRaWANDistance DetectionSensorx 11080 +* SW3L-LB LoRaWAN Flow Sensor 733 733 734 734 (% style="color:#037691" %)**Dimension and weight**: 735 735 ... ... @@ -741,12 +741,9 @@ 741 741 742 742 * Weight / pcs : g 743 743 1092 += 9. Support = 744 744 745 745 746 - 747 -= 10. Support = 748 - 749 - 750 750 * Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule. 751 751 752 752 * Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[Support@dragino.cc>>mailto:Support@dragino.cc]].