Last modified by Mengting Qiu on 2023/12/14 11:15

From version 70.14
edited by Xiaoling
on 2023/06/13 08:45
Change comment: There is no comment for this version
To version 70.9
edited by Xiaoling
on 2023/06/12 17:46
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -22,13 +22,13 @@
22 22  
23 23  It detects the distance(% style="color:blue" %)**  between the measured object and the sensor**(%%), and uploads the value via wireless to LoRaWAN IoT Server.
24 24  
25 -The LoRa wireless technology used in DDS75-LB allows device to send data and reach extremely long ranges at low data-rates. It provides ultra-long range spread spectrum communication and high interference immunity whilst minimizing current consumption.
25 +The LoRa wireless technology used in SW3L-LB allows device to send data and reach extremely long ranges at low data-rates. It provides ultra-long range spread spectrum communication and high interference immunity whilst minimizing current consumption.
26 26  
27 -DDS75-LB (% style="color:blue" %)**supports BLE configure**(%%) and (% style="color:blue" %)**wireless OTA update**(%%) which make user easy to use.
27 +SW3L-LB (% style="color:blue" %)**supports BLE configure**(%%) and (% style="color:blue" %)**wireless OTA update**(%%) which make user easy to use.
28 28  
29 -DDS75-LB is powered by (% style="color:blue" %)**8500mAh Li-SOCI2 battery**(%%), it is designed for long term use up to 5 years.
29 +SW3L-LB is powered by (% style="color:blue" %)**8500mAh Li-SOCI2 battery**(%%), it is designed for long term use up to 5 years.
30 30  
31 -Each DDS75-LB is pre-load with a set of unique keys for LoRaWAN registrations, register these keys to local LoRaWAN server and it will auto connect after power on.
31 +Each SW3L-LB is pre-load with a set of unique keys for LoRaWAN registrations, register these keys to local LoRaWAN server and it will auto connect after power on.
32 32  
33 33  [[image:image-20230612170943-2.png||height="525" width="912"]]
34 34  
... ... @@ -105,6 +105,7 @@
105 105  * Sleep Mode: 5uA @ 3.3v
106 106  * LoRa Transmit Mode: 125mA @ 20dBm, 82mA @ 14dBm
107 107  
108 +
108 108  == 1.4 Effective measurement range Reference beam pattern ==
109 109  
110 110  
... ... @@ -192,18 +192,6 @@
192 192  [[image:Main.User Manual for LoRaWAN End Nodes.D20-LBD22-LBD23-LB_LoRaWAN_Temperature_Sensor_User_Manual.WebHome@1675143909447-639.png]]
193 193  
194 194  
195 -**Probe Mechanical:**
196 -
197 -
198 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDDS75%20-%20LoRaWAN%20Distance%20Detection%20Sensor%20User%20Manual/WebHome/image-20220610172003-1.png?rev=1.1||alt="image-20220610172003-1.png"]]
199 -
200 -
201 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDDS75%20-%20LoRaWAN%20Distance%20Detection%20Sensor%20User%20Manual/WebHome/image-20220610172003-2.png?rev=1.1||alt="image-20220610172003-2.png"]]
202 -
203 -
204 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDDS75%20-%20LoRaWAN%20Distance%20Detection%20Sensor%20User%20Manual/WebHome/image-20220610172003-2.png?rev=1.1||alt="image-20220610172003-2.png"]]
205 -
206 -
207 207  = 2. Configure DDS75-LB to connect to LoRaWAN network =
208 208  
209 209  == 2.1 How it works ==
... ... @@ -264,178 +264,355 @@
264 264  After join success, it will start to upload messages to TTN and you can see the messages in the panel.
265 265  
266 266  
267 -== 2.3  ​Uplink Payload ==
256 +== 2.3 ​Uplink Payload ==
268 268  
258 +=== 2.3.1 Device Status, FPORT~=5 ===
269 269  
260 +
261 +Include device configure status. Once SW3L-LB Joined the network, it will uplink this message to the server. After that, SW3L-LB will uplink Device Status every 12 hours.
262 +
263 +Users can use the downlink command(**0x26 01**) to ask SW3L-LB to send device configure detail, include device configure status. SW3L-LB will uplink a payload via FPort=5 to server.
264 +
265 +The Payload format is as below.
266 +
267 +
268 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %)
269 +|(% colspan="6" style="background-color:#d9e2f3; color:#0070c0" %)**Device Status (FPORT=5)**
270 +|(% style="width:103px" %)**Size (bytes)**|(% style="width:72px" %)**1**|**2**|(% style="width:91px" %)**1**|(% style="width:86px" %)**1**|(% style="width:44px" %)**2**
271 +|(% style="width:103px" %)**Value**|(% style="width:72px" %)Sensor Model|Firmware Version|(% style="width:91px" %)Frequency Band|(% style="width:86px" %)Sub-band|(% style="width:44px" %)BAT
272 +
273 +Example parse in TTNv3
274 +
275 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/SW3L%20LoRaWAN%20Outdoor%20Flow%20Sensor/WebHome/1652925144491-755.png?width=732&height=139&rev=1.1||alt="1652925144491-755.png"]]
276 +
277 +
278 +(% style="color:#037691" %)**Sensor Model**(%%): For SW3L-LB, this value is 0x11
279 +
280 +(% style="color:#037691" %)**Firmware Version**(%%): 0x0100, Means: v1.0.0 version
281 +
282 +(% style="color:#037691" %)**Frequency Band**:
283 +
284 +*0x01: EU868
285 +
286 +*0x02: US915
287 +
288 +*0x03: IN865
289 +
290 +*0x04: AU915
291 +
292 +*0x05: KZ865
293 +
294 +*0x06: RU864
295 +
296 +*0x07: AS923
297 +
298 +*0x08: AS923-1
299 +
300 +*0x09: AS923-2
301 +
302 +*0x0a: AS923-3
303 +
304 +*0x0b: CN470
305 +
306 +*0x0c: EU433
307 +
308 +*0x0d: KR920
309 +
310 +*0x0e: MA869
311 +
312 +
313 +(% style="color:#037691" %)**Sub-Band**:
314 +
315 +AU915 and US915:value 0x00 ~~ 0x08
316 +
317 +CN470: value 0x0B ~~ 0x0C
318 +
319 +Other Bands: Always 0x00
320 +
321 +
322 +(% style="color:#037691" %)**Battery Info**:
323 +
324 +Check the battery voltage.
325 +
326 +Ex1: 0x0B45 = 2885mV
327 +
328 +Ex2: 0x0B49 = 2889mV
329 +
330 +
331 +=== 2.3.2 Sensor Configuration, FPORT~=4 ===
332 +
333 +
334 +SW3L-LB will only send this command after getting the downlink command (0x26 02) from the server.
335 +
336 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:510px" %)
337 +|(% style="background-color:#d9e2f3; color:#0070c0; width:70px" %) **Size(bytes)**|(% style="background-color:#d9e2f3; color:#0070c0; width:105px" %)**3**|(% style="background-color:#d9e2f3; color:#0070c0; width:60px" %)**1**|(% style="background-color:#d9e2f3; color:#0070c0; width:96px" %)**1**|(% style="background-color:#d9e2f3; color:#0070c0; width:105px" %)**2**|(% style="background-color:#d9e2f3; color:#0070c0; width:74px" %)**1**
338 +|**Value**|(% style="width:104px" %)TDC(unit:sec)|(% style="width:43px" %)N/A|(% style="width:91px" %)Stop Timer|(% style="width:100px" %)Alarm Timer|(% style="width:69px" %)Reserve
339 +
340 +* (% style="color:#037691" %)**TDC: (default: 0x0004B0)**
341 +
342 +Uplink interval for the total pulse count, default value is 0x0004B0 which is 1200 seconds = 20 minutes.
343 +
344 +
345 +* (% style="color:#037691" %)**STOP Duration & Alarm Timer**
346 +
347 +Shows the configure value of [[Alarm for continuously water flow>>||anchor="H3.3.4Alarmforcontinuouslywaterflow"]]
348 +
349 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/SW3L%20LoRaWAN%20Outdoor%20Flow%20Sensor/WebHome/image-20220519095747-2.png?width=723&height=113&rev=1.1||alt="image-20220519095747-2.png"]]
350 +
351 +
352 +=== 2.3.3 Water Flow Value, Uplink FPORT~=2 ===
353 +
354 +
270 270  (((
271 -(((
272 -DDS75-LB will uplink payload via LoRaWAN with below payload format: 
356 +SW3L-LB will send this uplink **after** Device Status once join the LoRaWAN network successfully. And SW3L-LB will:
273 273  )))
274 274  
275 275  (((
276 -Uplink payload includes in total 4 bytes.
277 -Payload for firmware version v1.1.4. . Before v1.1.3, there is on two fields: BAT and Distance
360 +periodically send this uplink every 20 minutes, this interval [[can be changed>>||anchor="H3.3.1SetTransmitIntervalTime"]].
278 278  )))
279 -)))
280 280  
281 281  (((
282 -
364 +Uplink Payload totals 11 bytes.
283 283  )))
284 284  
285 285  (% border="1" cellspacing="5" style="background-color:#f2f2f2; width:510px" %)
286 -|=(% style="width: 62.5px;background-color:#D9E2F3;color:#0070C0" %)(((
287 -**Size(bytes)**
288 -)))|=(% style="width: 62.5px;background-color:#D9E2F3;color:#0070C0" %)**2**|=(% style="background-color:#D9E2F3;color:#0070C0" %)**2**|=(% style="background-color:#D9E2F3;color:#0070C0" %)1|=(% style="background-color:#D9E2F3;color:#0070C0" %)2|=(% style="background-color:#D9E2F3;color:#0070C0" %)**1**
289 -|(% style="width:62.5px" %)**Value**|(% style="width:62.5px" %)[[BAT>>||anchor="H2.3.1A0BatteryInfo"]]|(((
290 -[[Distance>>||anchor="H2.3.2A0Distance"]]
291 -(unit: mm)
292 -)))|[[Digital Interrupt (Optional)>>||anchor="H2.3.3A0InterruptPin"]]|(((
293 -[[Temperature (Optional )>>||anchor="H2.3.4A0DS18B20Temperaturesensor"]]
294 -)))|[[Sensor Flag>>||anchor="H2.3.5A0SensorFlag"]]
368 +|=(% colspan="6" style="width: 510px;background-color:#D9E2F3;color:#0070C0" %)**Water Flow Value,  FPORT=2**
369 +|(% style="width:60px" %)**Size(bytes)**|(% style="width:130px" %)**1**|(% style="width:130px" %)**4**|(% style="width:30px" %)**1**|(% style="width:50px" %)**1**|(% style="width:80px" %)**4**
370 +|(% style="width:110px" %)**Value**|(% style="width:81px" %)Calculate Flag & [[Alarm>>||anchor="H3.3.4Alarmforcontinuouslywaterflow"]]|(% style="width:95px" %)(((
371 +Total pulse Or Last Pulse
372 +)))|(% style="width:55px" %)MOD|(% style="width:115px" %)Reserve(0x01)|(% style="width:129px" %)[[Unix TimeStamp>>||anchor="H2.5.2UnixTimeStamp"]]
295 295  
296 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDDS75%20-%20LoRaWAN%20Distance%20Detection%20Sensor%20User%20Manual/WebHome/1654850511545-399.png?rev=1.1||alt="1654850511545-399.png"]]
374 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:470px" %)
375 +|=(% colspan="4" style="width: 470px;background-color:#D9E2F3;color:#0070C0" %)**Status & Alarm field**
376 +|(% style="width:60px" %)**Size(bit)**|(% style="width:80px" %)**6**|(% style="width:310px" %)**1**|(% style="width:20px" %)**1**
377 +|(% style="width:88px" %)**Value**|(% style="width:117px" %)Calculate Flag|(% style="width:221px" %)Alarm: 0: No Alarm; 1: Alarm|(% style="width:64px" %)N/A
297 297  
379 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/SW3L%20LoRaWAN%20Outdoor%20Flow%20Sensor/WebHome/image-20220519095946-3.png?width=736&height=284&rev=1.1||alt="image-20220519095946-3.png"]]
298 298  
299 -=== 2.3.1  Battery Info ===
300 300  
382 +* (((
383 +(% style="color:#037691" %)**Calculate Flag**
384 +)))
301 301  
302 -Check the battery voltage for DDS75-LB.
386 +(((
387 +The calculate flag is a user defined field, IoT server can use this flag to handle different meters with different pulse factors. For example, if there are 100 Flow Sensors, meters 1 ~~50 are 1 liter/pulse and meters 51 ~~ 100 has 1.5 liter/pulse.
388 +)))
303 303  
304 -Ex1: 0x0B45 = 2885mV
390 +(((
391 +**Example: in the default payload:**
392 +)))
305 305  
306 -Ex2: 0x0B49 = 2889mV
394 +* (((
395 +calculate flag=0: for SW3L-004 Flow Sensor: 450 pulse = 1 L
396 +)))
397 +* (((
398 +calculate flag=1: for SW3L-006 Flow Sensor: 390 pulse = 1 L
399 +)))
400 +* (((
401 +calculate flag=2: for SW3L-010 Flow Sensor: 64 pulse = 1 L
402 +)))
307 307  
404 +(((
405 +Default value: 0. 
406 +)))
308 308  
309 -=== 2.3.2  Distance ===
408 +(((
409 +Range (6 bits): (b)000000 ~~ (b) 111111
310 310  
411 +If user use with a meter for example is 0.02L/pulse. To proper decode the correct value in server,
311 311  
312 -(((
313 -Get the distance. Flat object range 280mm - 7500mm.
413 +1) User can set the Calculate Flag of this sensor to 3.
414 +
415 +2) In server side, when a sensor data arrive, the decoder will check the value of Calculate Flag, It the value is 3, the total volume = 0.02 x Pulse Count.
314 314  )))
315 315  
316 316  (((
317 -For example, if the data you get from the register is 0x0B 0x05, the distance between the sensor and the measured object is(% style="color:#4472c4" %)** **
419 +(% style="color:red" %)**NOTE: User need to set Calculate Flag to proper value before use Flow Sensor. Downlink or AT Command see: **(%%)Refer: [[Set Calculate Flag>>||anchor="H3.3.6Setthecalculateflag"]]
420 +)))
318 318  
319 -(% style="color:#4472c4" %)**0B05(H) = 2821 (D) = 2821 mm.**
422 +* (((
423 +(% style="color:#037691" %)**Alarm**
320 320  )))
321 321  
426 +(((
427 +See [[Alarm for continuously water flow>>||anchor="H3.3.4Alarmforcontinuouslywaterflow"]]
428 +)))
322 322  
323 -* If the sensor value is 0x0000, it means system doesn't detect ultrasonic sensor.
324 -* If the sensor value lower than 0x0118 (280mm), the sensor value will be invalid. Since v1.1.4, all value lower than 280mm will be set to 0x0014(20mm) which means the value is invalid.
430 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/SW3L%20LoRaWAN%20Outdoor%20Flow%20Sensor/WebHome/image-20220519095946-4.png?width=724&height=65&rev=1.1||alt="image-20220519095946-4.png"]]
325 325  
326 -=== 2.3.3  Interrupt Pin ===
327 327  
433 +* (((
434 +(% style="color:#037691" %)**Total pulse**
435 +)))
328 328  
329 -This data field shows if this packet is generated by interrupt or not. [[Click here>>||anchor="H3.3A0SetInterruptMode"]] for the hardware and software set up.
437 +(((
438 +Total pulse/counting since factory
439 +)))
330 330  
331 -**Example:**
441 +(((
442 +Range (4 Bytes) : 0x00000000~~ 0xFFFFFFFF .
443 +)))
332 332  
333 -0x00: Normal uplink packet.
445 +* (((
446 +(% style="color:#037691" %)**Last Pulse**
447 +)))
334 334  
335 -0x01: Interrupt Uplink Packet.
449 +(((
450 +Total pulse since last FPORT=2 uplink. (Default 20 minutes)
451 +)))
336 336  
453 +(((
454 +Range (4 Bytes) : 0x00000000~~ 0xFFFFFFFF .
455 +)))
337 337  
338 -=== 2.3.4  DS18B20 Temperature sensor ===
457 +* (((
458 +(% style="color:#037691" %)**MOD: Default =0**
459 +)))
339 339  
461 +(((
462 +MOD=0 ~-~-> Uplink Total Pulse since factory
463 +)))
340 340  
341 -This is optional, user can connect external DS18B20 sensor to the +3.3v, 1-wire and GND pin . and this field will report temperature.
465 +(((
466 +MOD=1 ~-~-> Uplink total pulse since last FPORT=2 uplink.
467 +)))
342 342  
343 -**Example**:
469 +* (((
470 +(% style="color:#037691" %)**Water Flow Value**
471 +)))
344 344  
345 -If payload is: 0105H:  (0105 & FC00 == 0), temp = 0105H /10 = 26.1 degree
473 +(((
474 +**Total Water Flow Volume = (Calculate Flag) x (Total Pulse)=9597/450=21.3L**
475 +)))
346 346  
347 -If payload is: FF3FH :  (FF3F & FC00 == 1) , temp = (FF3FH - 65536)/10 = -19.3 degrees.
477 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/SW3L%20LoRaWAN%20Outdoor%20Flow%20Sensor/WebHome/image-20220519095946-5.png?width=727&height=50&rev=1.1||alt="image-20220519095946-5.png"]]
348 348  
349 -(% style="color:red" %)**Note: DS18B20 feature is supported in the hardware version > v1.3 which made since early of 2021.**
350 350  
480 +(((
481 +**Total Water Flow for TDC timer = (Calculate Flag) x (Last Pulse)=79/450=0.2L**
482 +)))
351 351  
352 -=== 2.3.5  Sensor Flag ===
484 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/SW3L%20LoRaWAN%20Outdoor%20Flow%20Sensor/WebHome/image-20220519095946-6.png?width=733&height=43&rev=1.1||alt="image-20220519095946-6.png"]] ** **
353 353  
354 354  
487 +=== 2.3.4 Historical Water Flow Status, FPORT~=3 ===
488 +
489 +
355 355  (((
356 -0x01: Detect Ultrasonic Sensor
491 +SW3L-LB stores sensor values and users can retrieve these history values via the [[downlink command>>||anchor="H2.5DatalogFeature"]].
357 357  )))
358 358  
359 359  (((
360 -0x00: No Ultrasonic Sensor
495 +The historical payload includes one or multiplies entries and every entry has the same payload as Real-Time water flow status.
361 361  )))
362 362  
498 +* (((
499 +Each data entry is 11 bytes and has the same structure as [[real time water flow status>>||anchor="H2.3.3A0WaterFlowValue2CUplinkFPORT3D2"]], to save airtime and battery, SW3L will send max bytes according to the current DR and Frequency bands.
500 +)))
363 363  
364 -=== 2.3.6  Decode payload in The Things Network ===
502 +(((
503 +For example, in the US915 band, the max payload for different DR is:
504 +)))
365 365  
506 +(((
507 +(% style="color:blue" %)**a) DR0:**(%%) max is 11 bytes so one entry of data
508 +)))
366 366  
367 -While using TTN network, you can add the payload format to decode the payload.
510 +(((
511 +(% style="color:blue" %)**b) DR1:**(%%) max is 53 bytes so devices will upload 4 entries of data (total 44 bytes)
512 +)))
368 368  
369 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDDS75%20-%20LoRaWAN%20Distance%20Detection%20Sensor%20User%20Manual/WebHome/1654850829385-439.png?rev=1.1||alt="1654850829385-439.png"]]
514 +(((
515 +(% style="color:blue" %)**c) DR2:**(%%) total payload includes 11 entries of data
516 +)))
370 370  
371 -The payload decoder function for TTN V3 is here:
518 +(((
519 +(% style="color:blue" %)**d) DR3:**(%%) total payload includes 22 entries of data.
520 +)))
372 372  
373 373  (((
374 -DDS75-LB TTN V3 Payload Decoder:  [[ttps:~~/~~/github.com/dragino/dragino-end-node-decoder>>https://github.com/dragino/dragino-end-node-decoder]]
523 +If SW3L-LB doesn't have any data in the polling time. It will uplink 11 bytes of 0
375 375  )))
376 376  
526 +(((
527 +(% style="color:#037691" %)**Downlink:**
528 +)))
377 377  
378 -== 2.4  Uplink Interval ==
530 +(((
531 +0x31 62 46 B1 F0 62 46 B3 94 07
532 +)))
379 379  
534 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/SW3L%20LoRaWAN%20Outdoor%20Flow%20Sensor/WebHome/1652926690850-712.png?width=726&height=115&rev=1.1||alt="1652926690850-712.png"]]
380 380  
381 -The DDS75-LB by default uplink the sensor data every 20 minutes. User can change this interval by AT Command or LoRaWAN Downlink Command. See this link: [[Change Uplink Interval>>doc:Main.End Device AT Commands and Downlink Command.WebHome||anchor="H4.1ChangeUplinkInterval"]]
382 382  
383 -
384 -== 2.5  ​Show Data in DataCake IoT Server ==
385 -
386 -
387 387  (((
388 -[[DATACAKE>>url:https://datacake.co/]] provides a human friendly interface to show the sensor data, once we have data in TTN, we can use [[DATACAKE>>url:https://datacake.co/]] to connect to TTN and see the data in DATACAKE. Below are the steps:
538 +(% style="color:#037691" %)**Uplink:**
389 389  )))
390 390  
391 391  (((
392 -
542 +00 00 01 00 00 00 00 62 46 B2 26 00 00 01 00 00 00 00 62 46 B2 5D 00 00 01 00 00 00 00 62 46 B2 99 00 00 01 00 00 00 00 62 46 B2 D5 00 00 01 00 00 01 15 62 46 B3 11 00 00 01 00 00 01 1F 62 46 B3 7E
393 393  )))
394 394  
395 395  (((
396 -(% style="color:blue" %)**Step 1**(%%)**: Be sure that your device is programmed and properly connected to the network at this time.**
546 +(% style="color:#037691" %)**Parsed Value:**
397 397  )))
398 398  
399 399  (((
400 -(% style="color:blue" %)**Step 2**(%%)**: To configure the Application to forward data to DATACAKE you will need to add integration. To add the DATACAKE integration, perform the following steps:**
550 +[Alarm, Calculate Flag, MOD, Total pulse or Last Pulse,** **Water Flow Value, TIME]
401 401  )))
402 402  
403 403  
404 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDDS75%20-%20LoRaWAN%20Distance%20Detection%20Sensor%20User%20Manual/WebHome/1654592790040-760.png?rev=1.1||alt="1654592790040-760.png"]]
554 +(((
555 +[FALSE,0,0,0,0.0,2022-04-01 08:04:54],
556 +)))
405 405  
558 +(((
559 +[FALSE,0,0,0,0.0,2022-04-01 08:05:49],
560 +)))
406 406  
407 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDDS75%20-%20LoRaWAN%20Distance%20Detection%20Sensor%20User%20Manual/WebHome/1654592800389-571.png?rev=1.1||alt="1654592800389-571.png"]]
562 +(((
563 +[FALSE,0,0,0,0.0,2022-04-01 08:06:49],
564 +)))
408 408  
566 +(((
567 +[FALSE,0,0,0,0.0,2022-04-01 08:07:49],
568 +)))
409 409  
410 -(% style="color:blue" %)**Step 3**(%%)**: Create an account or log in Datacake.**
570 +(((
571 +[FALSE,0,0,277,0.6,2022-04-01 08:08:49],
572 +)))
411 411  
412 -(% style="color:blue" %)**Step 4**(%%)**: Search the DDS75-LB and add DevEUI.**
574 +(((
575 +[FALSE,0,0,287,0.6,2022-04-01 08:10:38],
576 +)))
413 413  
414 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDDS75%20-%20LoRaWAN%20Distance%20Detection%20Sensor%20User%20Manual/WebHome/1654851029373-510.png?rev=1.1||alt="1654851029373-510.png"]]
578 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/SW3L%20LoRaWAN%20Outdoor%20Flow%20Sensor/WebHome/1652926777796-267.png?width=724&height=279&rev=1.1||alt="1652926777796-267.png"]]
415 415  
416 416  
417 -After added, the sensor data arrive TTN V3, it will also arrive and show in Datacake.
581 +== 2.4 Payload Decoder file ==
418 418  
419 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDDS75%20-%20LoRaWAN%20Distance%20Detection%20Sensor%20User%20Manual/WebHome/image-20220610165129-11.png?width=1088&height=595&rev=1.1||alt="image-20220610165129-11.png"]]
420 420  
584 +In TTN, use can add a custom payload so it shows friendly reading
421 421  
586 +In the page (% style="color:#037691" %)**Applications ~-~-> Payload Formats ~-~-> Custom ~-~-> decoder**(%%) to add the decoder from: [[https:~~/~~/github.com/dragino/dragino-end-node-decoder>>https://github.com/dragino/dragino-end-node-decoder]]
422 422  
423 -== 2.6 Datalog Feature ==
424 424  
589 +== 2.5 Datalog Feature ==
425 425  
426 -Datalog Feature is to ensure IoT Server can get all sampling data from Sensor even if the LoRaWAN network is down. For each sampling, DDS75-LB will store the reading for future retrieving purposes.
427 427  
592 +Datalog Feature is to ensure IoT Server can get all sampling data from Sensor even if the LoRaWAN network is down. For each sampling, SW3L-LB will store the reading for future retrieving purposes.
428 428  
429 -=== 2.6.1 Ways to get datalog via LoRaWAN ===
430 430  
595 +=== 2.5.1 Ways to get datalog via LoRaWAN ===
431 431  
432 -Set PNACKMD=1, DDS75-LB will wait for ACK for every uplink, when there is no LoRaWAN network,DDS75-LB will mark these records with non-ack messages and store the sensor data, and it will send all messages (10s interval) after the network recovery.
433 433  
598 +Set PNACKMD=1, SW3L-LB will wait for ACK for every uplink, when there is no LoRaWAN network,SW3L-LB will mark these records with non-ack messages and store the sensor data, and it will send all messages (10s interval) after the network recovery.
599 +
434 434  * (((
435 -a) DDS75-LB will do an ACK check for data records sending to make sure every data arrive server.
601 +a) SW3L-LB will do an ACK check for data records sending to make sure every data arrive server.
436 436  )))
437 437  * (((
438 -b) DDS75-LB will send data in **CONFIRMED Mode** when PNACKMD=1, but DDS75-LB won't re-transmit the packet if it doesn't get ACK, it will just mark it as a NONE-ACK message. In a future uplink if DDS75-LB gets a ACK, DDS75-LB will consider there is a network connection and resend all NONE-ACK messages.
604 +b) SW3L-LB will send data in **CONFIRMED Mode** when PNACKMD=1, but SW3L-LB won't re-transmit the packet if it doesn't get ACK, it will just mark it as a NONE-ACK message. In a future uplink if SW3L-LB gets a ACK, SW3L-LB will consider there is a network connection and resend all NONE-ACK messages.
439 439  )))
440 440  
441 441  Below is the typical case for the auto-update datalog feature (Set PNACKMD=1)
... ... @@ -443,10 +443,10 @@
443 443  [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/WebHome/image-20220703111700-2.png?width=1119&height=381&rev=1.1||alt="图片-20220703111700-2.png" height="381" width="1119"]]
444 444  
445 445  
446 -=== 2.6.2 Unix TimeStamp ===
612 +=== 2.5.2 Unix TimeStamp ===
447 447  
448 448  
449 -DDS75-LB uses Unix TimeStamp format based on
615 +SW3L-LB uses Unix TimeStamp format based on
450 450  
451 451  [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/WebHome/image-20220523001219-11.png?width=627&height=97&rev=1.1||alt="图片-20220523001219-11.png" height="97" width="627"]]
452 452  
... ... @@ -460,17 +460,17 @@
460 460  So, we can use AT+TIMESTAMP=1611889405 or downlink 3060137afd00 to set the current time 2021 – Jan ~-~- 29 Friday 03:03:25
461 461  
462 462  
463 -=== 2.6.3 Set Device Time ===
629 +=== 2.5.3 Set Device Time ===
464 464  
465 465  
466 466  User need to set (% style="color:blue" %)**SYNCMOD=1**(%%) to enable sync time via MAC command.
467 467  
468 -Once DDS75-LB Joined LoRaWAN network, it will send the MAC command (DeviceTimeReq) and the server will reply with (DeviceTimeAns) to send the current time to DDS75-LB. If DDS75-LB fails to get the time from the server, DDS75-LB will use the internal time and wait for next time request (AT+SYNCTDC to set the time request period, default is 10 days).
634 +Once SW3L-LB Joined LoRaWAN network, it will send the MAC command (DeviceTimeReq) and the server will reply with (DeviceTimeAns) to send the current time to SW3L-LB. If SW3L-LB fails to get the time from the server, SW3L-LB will use the internal time and wait for next time request (AT+SYNCTDC to set the time request period, default is 10 days).
469 469  
470 470  (% style="color:red" %)**Note: LoRaWAN Server need to support LoRaWAN v1.0.3(MAC v1.0.3) or higher to support this MAC command feature, Chirpstack,TTN V3 v3 and loriot support but TTN V3 v2 doesn't support. If server doesn't support this command, it will through away uplink packet with this command, so user will lose the packet with time request for TTN V3 v2 if SYNCMOD=1.**
471 471  
472 472  
473 -=== 2.6.4 Poll sensor value ===
639 +=== 2.5.4 Poll sensor value ===
474 474  
475 475  
476 476  Users can poll sensor values based on timestamps. Below is the downlink command.
... ... @@ -493,24 +493,24 @@
493 493  )))
494 494  
495 495  (((
496 -Uplink Internal =5s,means DDS75-LB will send one packet every 5s. range 5~~255s.
662 +Uplink Internal =5s,means SW3L-LB will send one packet every 5s. range 5~~255s.
497 497  )))
498 498  
499 499  
500 -== 2.7 Frequency Plans ==
666 +== 2.6 Frequency Plans ==
501 501  
502 502  
503 -The DDS75-LB uses OTAA mode and below frequency plans by default. If user want to use it with different frequency plan, please refer the AT command sets.
669 +The SW3L-LB uses OTAA mode and below frequency plans by default. If user want to use it with different frequency plan, please refer the AT command sets.
504 504  
505 505  [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20Frequency%20Band/>>http://wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20Frequency%20Band/]]
506 506  
507 507  
508 -= 3. Configure DDS75-LB =
674 += 3. Configure SW3L-LB =
509 509  
510 510  == 3.1 Configure Methods ==
511 511  
512 512  
513 -DDS75-LB supports below configure method:
679 +SW3L-LB supports below configure method:
514 514  
515 515  * AT Command via Bluetooth Connection (**Recommended**): [[BLE Configure Instruction>>http://wiki.dragino.com/xwiki/bin/view/Main/BLE%20Bluetooth%20Remote%20Configure/]].
516 516  
... ... @@ -532,10 +532,10 @@
532 532  [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/>>http://wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/]]
533 533  
534 534  
535 -== 3.3 Commands special design for DDS75-LB ==
701 +== 3.3 Commands special design for SW3L-LB ==
536 536  
537 537  
538 -These commands only valid for DDS75-LB, as below:
704 +These commands only valid for SW3L-LB, as below:
539 539  
540 540  
541 541  === 3.3.1 Set Transmit Interval Time ===
... ... @@ -580,135 +580,259 @@
580 580  Example 2: Downlink Payload: 0100003C  ~/~/ Set Transmit Interval (TDC) = 60 seconds
581 581  )))
582 582  
583 -=== 3.3.2 Set Interrupt Mode ===
749 +=== 3.3.2 Quit AT Command ===
584 584  
585 585  
586 -Feature, Set Interrupt mode for PA8 of pin.
752 +Feature: Quit AT Command mode, so user needs to input the password again before using AT Commands.
587 587  
588 -When AT+INTMOD=0 is set, PA8 is used as a digital input port.
754 +(% style="color:blue" %)**AT Command: AT+DISAT**
589 589  
590 -(% style="color:blue" %)**AT Command: AT+INTMOD**
756 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:452px" %)
757 +|=(% style="width: 155px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 198px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 99px;background-color:#D9E2F3;color:#0070C0" %)**Response**
758 +|(% style="width:155px" %)AT+DISAT|(% style="width:198px" %)Quit AT Commands mode|(% style="width:96px" %)OK
591 591  
592 -(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %)
593 -|=(% style="width: 155px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 197px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 158px;background-color:#D9E2F3;color:#0070C0" %)**Response**
594 -|(% style="width:154px" %)AT+INTMOD=?|(% style="width:196px" %)Show current interrupt mode|(% style="width:157px" %)(((
595 -0
596 -OK
597 -the mode is 0 =Disable Interrupt
760 +(% style="color:blue" %)**Downlink Command:**
761 +
762 +No downlink command for this feature.
763 +
764 +
765 +=== 3.3.3 Get Device Status ===
766 +
767 +
768 +Send a LoRaWAN downlink to ask device send Alarm settings.
769 +
770 +(% style="color:blue" %)**Downlink Payload:  **(%%)0x26 01
771 +
772 +Sensor will upload Device Status via FPORT=5. See payload section for detail.
773 +
774 +
775 +=== 3.3.4 Alarm for continuously water flow ===
776 +
777 +
778 +(((
779 +This feature is to monitor and send Alarm for continuously water flow.
598 598  )))
599 -|(% style="width:154px" %)AT+INTMOD=2|(% style="width:196px" %)(((
600 -Set Transmit Interval
601 -0. (Disable Interrupt),
602 -~1. (Trigger by rising and falling edge)
603 -2. (Trigger by falling edge)
604 -3. (Trigger by rising edge)
605 -)))|(% style="width:157px" %)OK
606 606  
607 -(% style="color:blue" %)**Downlink Command: 0x06**
782 +(((
783 +Example case is for Toilet water monitoring, if some one push toilet button, the toilet will have water flow. If the toilet button has broken and can't returned to original state, the water flow will keep for hours or days which cause huge waste for water.
784 +)))
608 608  
609 -Format: Command Code (0x06) followed by 3 bytes.
786 +(((
787 +To monitor this faulty and send alarm, there are two settings:
788 +)))
610 610  
611 -This means that the interrupt mode of the end node is set to 0x000003=3 (rising edge trigger), and the type code is 06.
790 +* (((
791 +(% style="color:#4f81bd" %)**Stop Duration: Unit: Second**
792 +)))
612 612  
613 -* Example 1: Downlink Payload: 06000000  ~/~/  Turn off interrupt mode
794 +(((
795 +Default: 15s, If SW3L-LB didn't see any water flow in 15s, SW3L-LB will consider stop of water flow event.
796 +)))
614 614  
615 -* Example 2: Downlink Payload: 06000003  ~/~/  Set the interrupt mode to rising edge trigger
798 +* (((
799 +(% style="color:#4f81bd" %)**Alarm Timer: Units: Minute; Default 0 minutes (means Alarm disable)**
800 +)))
616 616  
617 -= 4. Battery & Power Consumption =
802 +(((
803 +**Example:** 3 minutes, if SW3L-LB detect a start of water flow event and didn't detect a stop event within Alarm timer, SW3L-LB will send an Alarm to indicate a water flow abnormal alarm.
804 +)))
618 618  
806 +(((
807 +So for example, If we set stop duration=15s and Alarm Timer=3minutes. If the toilet water flow continuously for more than 3 minutes, Sensor will send an alarm (in Confirmed MODE) to platform.
808 +)))
619 619  
620 -DDS75-LB use ER26500 + SPC1520 battery pack. See below link for detail information about the battery info and how to replace.
810 +(((
811 +(% style="color:red" %)**Note:** **After this alarm is send, sensor will consider a stop of water flow and count for another new event. So if water flow waste last for 1 hour, Sensor will keep sending alarm every 3 minutes.**
812 +)))
621 621  
622 -[[**Battery Info & Power Consumption Analyze**>>http://wiki.dragino.com/xwiki/bin/view/Main/How%20to%20calculate%20the%20battery%20life%20of%20Dragino%20sensors%3F/]] .
814 +(((
815 +(% style="color:#4f81bd" %)**AT Command**(%%) to configure:
816 +)))
623 623  
818 +* (((
819 +AT+PTRIG=15,3  ~-~-> Set Stop duration: 15s, Alarm Timer: 3 minutes.
820 +)))
624 624  
625 -= 5. OTA Firmware update =
822 +* (((
823 +AT+ PTRIG=15,0  ~-~-> Default Value, disable water waste Alarm.
824 +)))
626 626  
826 +(((
827 +(% style="color:#4f81bd" %)**Downlink Command**(%%) to configure: 
828 +)))
627 627  
628 -(% class="wikigeneratedid" %)
629 -User can change firmware DDS75-LB to:
830 +(((
831 +Command: **0xAA aa bb cc**
832 +)))
630 630  
631 -* Change Frequency band/ region.
834 +(((
835 +AA: Command Type Code
836 +)))
632 632  
633 -* Update with new features.
838 +(((
839 +aa: Stop duration
840 +)))
634 634  
635 -* Fix bugs.
842 +(((
843 +bb cc: Alarm Timer
844 +)))
636 636  
637 -Firmware and changelog can be downloaded from : **[[Firmware download link>>url:https://www.dropbox.com/sh/7la95mae0fn03xe/AACtzs-32m22TLb75B-iIr-Qa?dl=0]]**
846 +(((
847 +If user send 0xAA 0F 00 03: equal to AT+PTRIG=15,3
848 +)))
638 638  
639 -Methods to Update Firmware:
640 640  
641 -* (Recommanded way) OTA firmware update via wireless:   [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/Firmware%20OTA%20Update%20for%20Sensors/>>url:http://wiki.dragino.com/xwiki/bin/view/Main/Firmware%20OTA%20Update%20for%20Sensors/]]
851 +=== 3.3.5 Clear Flash Record ===
642 642  
643 -* Update through UART TTL interface. **[[Instruction>>url:http://wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H1.LoRaSTv4baseHardware]]**.
644 644  
645 -= 6. FAQ =
854 +Feature: Clear flash storage for data log feature.
646 646  
856 +(% style="color:blue" %)**AT Command: AT+CLRDTA**
647 647  
648 -== 6.1  What is the frequency plan for DDS75-LB? ==
858 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:500px" %)
859 +|=(% style="width: 157px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 169px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 174px;background-color:#D9E2F3;color:#0070C0" %)**Response**
860 +|(% style="width:157px" %)AT+CLRDTA|(% style="width:169px" %)Clear flash storage for data log feature.|Clear all stored sensor data… OK
649 649  
862 +(((
863 +(% style="color:blue" %)**Downlink Command:**
864 +)))
650 650  
651 -DDS75-LB use the same frequency as other Dragino products. User can see the detail from this link:  [[Introduction>>doc:Main.End Device Frequency Band.WebHome||anchor="H1.Introduction"]]
866 +(((
867 +* **Example**: 0xA301  ~/~/  Same as AT+CLRDTA
868 +)))
652 652  
653 653  
654 -== 6.2  Can I use DDS75-LB in condensation environment? ==
655 655  
872 +=== 3.3.6 Set the calculate flag ===
656 656  
657 -DDS75-LB is not suitable to be used in condensation environment. Condensation on the DDS75-LB probe will affect the reading and always got 0.
658 658  
875 +Feature: Set the calculate flag
659 659  
660 -= 7.  Trouble Shooting =
877 +(% style="color:blue" %)**AT Command: AT+CALCFLAG**
661 661  
662 -== 7.1  Why I can't join TTN V3 in US915 / AU915 bands? ==
879 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:461px" %)
880 +|=(% style="width: 158px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 193px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 110px;background-color:#D9E2F3;color:#0070C0" %)**Response**
881 +|(% style="width:158px" %)AT+CALCFLAG =1|(% style="width:192px" %)Set the calculate flag to 1.|(% style="width:109px" %)OK
882 +|(% style="width:158px" %)AT+CALCFLAG =2|(% style="width:192px" %)Set the calculate flag to 2.|(% style="width:109px" %)OK
663 663  
884 +(% style="color:blue" %)**Downlink Command:**
664 664  
665 -It is due to channel mapping. Please see below link:  [[Frequency band>>doc:Main.LoRaWAN Communication Debug.WebHome||anchor="H2.NoticeofUS9152FCN4702FAU915Frequencyband"]]
886 +* **Example**: 0XA501  ~/~/  Same as AT+CALCFLAG =1
666 666  
888 +=== 3.3.7 Set count number ===
667 667  
668 -== 7.2  AT Command input doesn't work ==
669 669  
891 +Feature: Manually set the count number
670 670  
671 -In the case if user can see the console output but can't type input to the device. Please check if you already include the (% style="color:blue" %)**ENTER**(%%) while sending out the command. Some serial tool doesn't send (% style="color:blue" %)**ENTER**(%%) while press the send key, user need to add ENTER in their string.
893 +(% style="color:blue" %)**AT Command: AT+SETCNT**
672 672  
895 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:479px" %)
896 +|=(% style="width: 160px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 223px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 96px;background-color:#D9E2F3;color:#0070C0" %)**Response**
897 +|(% style="width:160px" %)AT+ SETCNT =0|(% style="width:221px" %)Set the count number to 0.|(% style="width:95px" %)OK
898 +|(% style="width:160px" %)AT+ SETCNT =100|(% style="width:221px" %)Set the count number to 100.|(% style="width:95px" %)OK
673 673  
674 -== 7.3  Why does the sensor reading show 0 or "No sensor" ==
900 +(% style="color:blue" %)**Downlink Command:**
675 675  
902 +* **Example**: 0xA6000001  ~/~/  Same as AT+ SETCNT =1
676 676  
677 -~1. The measurement object is very close to the sensor, but in the blind spot of the sensor.
904 +* **Example**: 0xA6000064  ~/~/  Same as AT+ SETCNT =100
678 678  
679 -2. Sensor wiring is disconnected
906 +=== 3.3.8 Set Interrupt Mode ===
680 680  
681 -3. Not using the correct decoder
682 682  
909 +Feature, Set Interrupt mode for PA8 of pin.
683 683  
684 -== 5.4  Abnormal readings The gap between multiple readings is too large or the gap between the readings and the actual value is too large ==
911 +When AT+INTMOD=0 is set, PA8 is used as a digital input port.
685 685  
913 +(% style="color:blue" %)**AT Command: AT+INTMOD**
686 686  
687 -1) Please check if there is something on the probe affecting its measurement (condensed water, volatile oil, etc.)
915 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %)
916 +|=(% style="width: 155px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 197px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 158px;background-color:#D9E2F3;color:#0070C0" %)**Response**
917 +|(% style="width:154px" %)AT+INTMOD=?|(% style="width:196px" %)Show current interrupt mode|(% style="width:157px" %)(((
918 +0
919 +OK
920 +the mode is 0 =Disable Interrupt
921 +)))
922 +|(% style="width:154px" %)AT+INTMOD=2|(% style="width:196px" %)(((
923 +Set Transmit Interval
924 +0. (Disable Interrupt),
925 +~1. (Trigger by rising and falling edge)
926 +2. (Trigger by falling edge)
927 +3. (Trigger by rising edge)
928 +)))|(% style="width:157px" %)OK
688 688  
689 -2) Does it change with temperature, temperature will affect its measurement
930 +(% style="color:blue" %)**Downlink Command: 0x06**
690 690  
691 -3) If abnormal data occurs, you can turn on DEBUG mode, Please use downlink or AT COMMAN to enter DEBUG mode.
932 +Format: Command Code (0x06) followed by 3 bytes.
692 692  
693 -downlink command: (% style="color:blue" %)**F1 01**(%%), AT command: (% style="color:blue" %)**AT+DDEBUG=1**
934 +This means that the interrupt mode of the end node is set to 0x000003=3 (rising edge trigger), and the type code is 06.
694 694  
695 -4) After entering the debug mode, it will send 20 pieces of data at a time, and you can send its uplink to us for analysis
936 +* Example 1: Downlink Payload: 06000000  ~/~/  Turn off interrupt mode
696 696  
697 -[[image:image-20230113135125-2.png||height="136" width="1057"]]
938 +* Example 2: Downlink Payload: 06000003  ~/~/  Set the interrupt mode to rising edge trigger
698 698  
940 +=== 3.3.9 Set work mode ===
699 699  
700 -Its original payload will be longer than other data. Even though it is being parsed, it can be seen that it is abnormal data.
701 701  
702 -Please send the data to us for check.
943 +Feature: Manually set the work mode
703 703  
704 704  
705 -= 8. Order Info =
946 +(% style="color:blue" %)**AT Command: AT+MOD**
706 706  
948 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:463px" %)
949 +|=(% style="width: 162px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 193px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 108px;background-color:#D9E2F3;color:#0070C0" %)**Response**
950 +|(% style="width:162px" %)AT+MOD=0|(% style="width:191px" %)Set the work mode to 0.|(% style="width:106px" %)OK
951 +|(% style="width:162px" %)AT+MOD=1|(% style="width:191px" %)Set the work mode to 1|(% style="width:106px" %)OK
707 707  
708 -Part Number: (% style="color:blue" %)**DDS75-LB-XXX**
953 +(% style="color:blue" %)**Downlink Command:**
709 709  
710 -(% style="color:red" %)**XXX**(%%): **The default frequency band**
955 +* **Example: **0x0A00  ~/~/  Same as AT+MOD=0
711 711  
957 +* **Example:** 0x0A01  ~/~/  Same as AT+MOD=1
958 +
959 += 4. Battery & Power Consumption =
960 +
961 +
962 +SW3L-LB use ER26500 + SPC1520 battery pack. See below link for detail information about the battery info and how to replace.
963 +
964 +[[**Battery Info & Power Consumption Analyze**>>http://wiki.dragino.com/xwiki/bin/view/Main/How%20to%20calculate%20the%20battery%20life%20of%20Dragino%20sensors%3F/]] .
965 +
966 +
967 += 5. OTA Firmware update =
968 +
969 +
970 +(% class="wikigeneratedid" %)
971 +User can change firmware SW3L-LB to:
972 +
973 +* Change Frequency band/ region.
974 +
975 +* Update with new features.
976 +
977 +* Fix bugs.
978 +
979 +Firmware and changelog can be downloaded from : **[[Firmware download link>>url:https://www.dropbox.com/sh/kwqv57tp6pejias/AAAopYMATh1GM6fZ-VRCLrpDa?dl=0]]**
980 +
981 +Methods to Update Firmware:
982 +
983 +* (Recommanded way) OTA firmware update via wireless:   [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/Firmware%20OTA%20Update%20for%20Sensors/>>url:http://wiki.dragino.com/xwiki/bin/view/Main/Firmware%20OTA%20Update%20for%20Sensors/]]
984 +
985 +* Update through UART TTL interface. **[[Instruction>>url:http://wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H1.LoRaSTv4baseHardware]]**.
986 +
987 += 6. FAQ =
988 +
989 +== 6.1  AT Commands input doesn't work ==
990 +
991 +
992 +In the case if user can see the console output but can't type input to the device. Please check if you already include the (% style="color:green" %)**ENTER**(%%) while sending out the command. Some serial tool doesn't send (% style="color:green" %)**ENTER**(%%) while press the send key, user need to add ENTER in their string.
993 +
994 +
995 += 7. Order Info =
996 +
997 +
998 +Part Number: (% style="color:blue" %)**SW3L-LB-XXX-YYY**
999 +
1000 +(% style="color:red" %)**XXX**(%%): The default frequency band
1001 +
712 712  * (% style="color:red" %)**AS923**(%%): LoRaWAN AS923 band
713 713  
714 714  * (% style="color:red" %)**AU915**(%%): LoRaWAN AU915 band
... ... @@ -725,15 +725,43 @@
725 725  
726 726  * (% style="color:red" %)**CN470**(%%): LoRaWAN CN470 band
727 727  
1018 +(((
1019 +(% style="color:blue" %)**YYY**(%%): Flow Sensor Model:
1020 +)))
728 728  
1022 +(((
1023 + **004:** DW-004 Flow Sensor: diameter: G1/2” / DN15.  450 pulse = 1 L
1024 +)))
729 729  
1026 +(((
1027 + **006:** DW-006 Flow Sensor: diameter: G3/4” / DN20. 390 pulse = 1 L
1028 +)))
730 730  
731 -= 9. ​Packing Info =
1030 +(((
1031 + **010:** DW-010 Flow Sensor: diameter: G 1” / DN25. 64 pulse = 1 L
1032 +)))
732 732  
1034 +* (((
1035 +calculate flag=0: for SW3L-004 Flow Sensor: 450 pulse = 1 L
1036 +)))
733 733  
1038 +* (((
1039 +calculate flag=1: for SW3L-006 Flow Sensor: 390 pulse = 1 L
1040 +)))
1041 +
1042 +* (((
1043 +calculate flag=2: for SW3L-010 Flow Sensor: 64  pulse = 1 L
1044 +
1045 +
1046 +
1047 +)))
1048 +
1049 += 8. ​Packing Info =
1050 +
1051 +
734 734  (% style="color:#037691" %)**Package Includes**:
735 735  
736 -* DDS75-LB LoRaWAN Distance Detection Sensor x 1
1054 +* SW3L-LB LoRaWAN Flow Sensor
737 737  
738 738  (% style="color:#037691" %)**Dimension and weight**:
739 739  
... ... @@ -745,12 +745,9 @@
745 745  
746 746  * Weight / pcs : g
747 747  
1066 += 9. Support =
748 748  
749 749  
750 -
751 -= 10. Support =
752 -
753 -
754 754  * Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule.
755 755  
756 756  * Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[Support@dragino.cc>>mailto:Support@dragino.cc]].