Changes for page DS20L -- LoRaWAN Smart Distance Detector User Manual 01
Last modified by Mengting Qiu on 2023/12/14 11:15
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -22,13 +22,13 @@ 22 22 23 23 It detects the distance(% style="color:blue" %)** between the measured object and the sensor**(%%), and uploads the value via wireless to LoRaWAN IoT Server. 24 24 25 -The LoRa wireless technology used in DDS75-LB allows device to send data and reach extremely long ranges at low data-rates. It provides ultra-long range spread spectrum communication and high interference immunity whilst minimizing current consumption.25 +The LoRa wireless technology used in SW3L-LB allows device to send data and reach extremely long ranges at low data-rates. It provides ultra-long range spread spectrum communication and high interference immunity whilst minimizing current consumption. 26 26 27 - DDS75-LB (% style="color:blue" %)**supports BLE configure**(%%) and (% style="color:blue" %)**wireless OTA update**(%%) which make user easy to use.27 +SW3L-LB (% style="color:blue" %)**supports BLE configure**(%%) and (% style="color:blue" %)**wireless OTA update**(%%) which make user easy to use. 28 28 29 - DDS75-LB is powered by (% style="color:blue" %)**8500mAh Li-SOCI2 battery**(%%), it is designed for long term use up to 5 years.29 +SW3L-LB is powered by (% style="color:blue" %)**8500mAh Li-SOCI2 battery**(%%), it is designed for long term use up to 5 years. 30 30 31 -Each DDS75-LB is pre-load with a set of unique keys for LoRaWAN registrations, register these keys to local LoRaWAN server and it will auto connect after power on.31 +Each SW3L-LB is pre-load with a set of unique keys for LoRaWAN registrations, register these keys to local LoRaWAN server and it will auto connect after power on. 32 32 33 33 [[image:image-20230612170943-2.png||height="525" width="912"]] 34 34 ... ... @@ -423,19 +423,19 @@ 423 423 == 2.6 Datalog Feature == 424 424 425 425 426 -Datalog Feature is to ensure IoT Server can get all sampling data from Sensor even if the LoRaWAN network is down. For each sampling, DDS75-LB will store the reading for future retrieving purposes.426 +Datalog Feature is to ensure IoT Server can get all sampling data from Sensor even if the LoRaWAN network is down. For each sampling, SW3L-LB will store the reading for future retrieving purposes. 427 427 428 428 429 429 === 2.6.1 Ways to get datalog via LoRaWAN === 430 430 431 431 432 -Set PNACKMD=1, DDS75-LB will wait for ACK for every uplink, when there is no LoRaWAN network,DDS75-LB will mark these records with non-ack messages and store the sensor data, and it will send all messages (10s interval) after the network recovery.432 +Set PNACKMD=1, SW3L-LB will wait for ACK for every uplink, when there is no LoRaWAN network,SW3L-LB will mark these records with non-ack messages and store the sensor data, and it will send all messages (10s interval) after the network recovery. 433 433 434 434 * ((( 435 -a) DDS75-LB will do an ACK check for data records sending to make sure every data arrive server.435 +a) SW3L-LB will do an ACK check for data records sending to make sure every data arrive server. 436 436 ))) 437 437 * ((( 438 -b) DDS75-LB will send data in **CONFIRMED Mode** when PNACKMD=1, butDDS75-LB won't re-transmit the packet if it doesn't get ACK, it will just mark it as a NONE-ACK message. In a future uplink ifDDS75-LB gets a ACK,DDS75-LB will consider there is a network connection and resend all NONE-ACK messages.438 +b) SW3L-LB will send data in **CONFIRMED Mode** when PNACKMD=1, but SW3L-LB won't re-transmit the packet if it doesn't get ACK, it will just mark it as a NONE-ACK message. In a future uplink if SW3L-LB gets a ACK, SW3L-LB will consider there is a network connection and resend all NONE-ACK messages. 439 439 ))) 440 440 441 441 Below is the typical case for the auto-update datalog feature (Set PNACKMD=1) ... ... @@ -446,7 +446,7 @@ 446 446 === 2.6.2 Unix TimeStamp === 447 447 448 448 449 - DDS75-LB uses Unix TimeStamp format based on449 +SW3L-LB uses Unix TimeStamp format based on 450 450 451 451 [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/WebHome/image-20220523001219-11.png?width=627&height=97&rev=1.1||alt="图片-20220523001219-11.png" height="97" width="627"]] 452 452 ... ... @@ -465,7 +465,7 @@ 465 465 466 466 User need to set (% style="color:blue" %)**SYNCMOD=1**(%%) to enable sync time via MAC command. 467 467 468 -Once DDS75-LB Joined LoRaWAN network, it will send the MAC command (DeviceTimeReq) and the server will reply with (DeviceTimeAns) to send the current time toDDS75-LB. IfDDS75-LB fails to get the time from the server,DDS75-LB will use the internal time and wait for next time request (AT+SYNCTDC to set the time request period, default is 10 days).468 +Once SW3L-LB Joined LoRaWAN network, it will send the MAC command (DeviceTimeReq) and the server will reply with (DeviceTimeAns) to send the current time to SW3L-LB. If SW3L-LB fails to get the time from the server, SW3L-LB will use the internal time and wait for next time request (AT+SYNCTDC to set the time request period, default is 10 days). 469 469 470 470 (% style="color:red" %)**Note: LoRaWAN Server need to support LoRaWAN v1.0.3(MAC v1.0.3) or higher to support this MAC command feature, Chirpstack,TTN V3 v3 and loriot support but TTN V3 v2 doesn't support. If server doesn't support this command, it will through away uplink packet with this command, so user will lose the packet with time request for TTN V3 v2 if SYNCMOD=1.** 471 471 ... ... @@ -493,7 +493,7 @@ 493 493 ))) 494 494 495 495 ((( 496 -Uplink Internal =5s,means DDS75-LB will send one packet every 5s. range 5~~255s.496 +Uplink Internal =5s,means SW3L-LB will send one packet every 5s. range 5~~255s. 497 497 ))) 498 498 499 499 ... ... @@ -500,17 +500,17 @@ 500 500 == 2.7 Frequency Plans == 501 501 502 502 503 -The DDS75-LB uses OTAA mode and below frequency plans by default. If user want to use it with different frequency plan, please refer the AT command sets.503 +The SW3L-LB uses OTAA mode and below frequency plans by default. If user want to use it with different frequency plan, please refer the AT command sets. 504 504 505 505 [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20Frequency%20Band/>>http://wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20Frequency%20Band/]] 506 506 507 507 508 -= 3. Configure DDS75-LB =508 += 3. Configure SW3L-LB = 509 509 510 510 == 3.1 Configure Methods == 511 511 512 512 513 - DDS75-LB supports below configure method:513 +SW3L-LB supports below configure method: 514 514 515 515 * AT Command via Bluetooth Connection (**Recommended**): [[BLE Configure Instruction>>http://wiki.dragino.com/xwiki/bin/view/Main/BLE%20Bluetooth%20Remote%20Configure/]]. 516 516 ... ... @@ -532,10 +532,10 @@ 532 532 [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/>>http://wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/]] 533 533 534 534 535 -== 3.3 Commands special design for DDS75-LB ==535 +== 3.3 Commands special design for SW3L-LB == 536 536 537 537 538 -These commands only valid for DDS75-LB, as below:538 +These commands only valid for SW3L-LB, as below: 539 539 540 540 541 541 === 3.3.1 Set Transmit Interval Time === ... ... @@ -580,135 +580,259 @@ 580 580 Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds 581 581 ))) 582 582 583 -=== 3.3.2 Set InterruptMode===583 +=== 3.3.2 Quit AT Command === 584 584 585 585 586 -Feature ,SetInterruptmodeforPA8of pin.586 +Feature: Quit AT Command mode, so user needs to input the password again before using AT Commands. 587 587 588 - WhenAT+INTMOD=0 isset, PA8 isusedasaigitalinput port.588 +(% style="color:blue" %)**AT Command: AT+DISAT** 589 589 590 -(% style="color:blue" %)**AT Command: AT+INTMOD** 590 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:452px" %) 591 +|=(% style="width: 155px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 198px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 99px;background-color:#D9E2F3;color:#0070C0" %)**Response** 592 +|(% style="width:155px" %)AT+DISAT|(% style="width:198px" %)Quit AT Commands mode|(% style="width:96px" %)OK 591 591 592 -(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %) 593 -|=(% style="width: 155px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 197px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 158px;background-color:#D9E2F3;color:#0070C0" %)**Response** 594 -|(% style="width:154px" %)AT+INTMOD=?|(% style="width:196px" %)Show current interrupt mode|(% style="width:157px" %)((( 595 -0 596 -OK 597 -the mode is 0 =Disable Interrupt 594 +(% style="color:blue" %)**Downlink Command:** 595 + 596 +No downlink command for this feature. 597 + 598 + 599 +=== 3.3.3 Get Device Status === 600 + 601 + 602 +Send a LoRaWAN downlink to ask device send Alarm settings. 603 + 604 +(% style="color:blue" %)**Downlink Payload: **(%%)0x26 01 605 + 606 +Sensor will upload Device Status via FPORT=5. See payload section for detail. 607 + 608 + 609 +=== 3.3.4 Alarm for continuously water flow === 610 + 611 + 612 +((( 613 +This feature is to monitor and send Alarm for continuously water flow. 598 598 ))) 599 -|(% style="width:154px" %)AT+INTMOD=2|(% style="width:196px" %)((( 600 -Set Transmit Interval 601 -0. (Disable Interrupt), 602 -~1. (Trigger by rising and falling edge) 603 -2. (Trigger by falling edge) 604 -3. (Trigger by rising edge) 605 -)))|(% style="width:157px" %)OK 606 606 607 -(% style="color:blue" %)**Downlink Command: 0x06** 616 +((( 617 +Example case is for Toilet water monitoring, if some one push toilet button, the toilet will have water flow. If the toilet button has broken and can't returned to original state, the water flow will keep for hours or days which cause huge waste for water. 618 +))) 608 608 609 -Format: Command Code (0x06) followed by 3 bytes. 620 +((( 621 +To monitor this faulty and send alarm, there are two settings: 622 +))) 610 610 611 -This means that the interrupt mode of the end node is set to 0x000003=3 (rising edge trigger), and the type code is 06. 624 +* ((( 625 +(% style="color:#4f81bd" %)**Stop Duration: Unit: Second** 626 +))) 612 612 613 -* Example 1: Downlink Payload: 06000000 ~/~/ Turn off interrupt mode 628 +((( 629 +Default: 15s, If SW3L-LB didn't see any water flow in 15s, SW3L-LB will consider stop of water flow event. 630 +))) 614 614 615 -* Example 2: Downlink Payload: 06000003 ~/~/ Set the interrupt mode to rising edge trigger 632 +* ((( 633 +(% style="color:#4f81bd" %)**Alarm Timer: Units: Minute; Default 0 minutes (means Alarm disable)** 634 +))) 616 616 617 -= 4. Battery & Power Consumption = 636 +((( 637 +**Example:** 3 minutes, if SW3L-LB detect a start of water flow event and didn't detect a stop event within Alarm timer, SW3L-LB will send an Alarm to indicate a water flow abnormal alarm. 638 +))) 618 618 640 +((( 641 +So for example, If we set stop duration=15s and Alarm Timer=3minutes. If the toilet water flow continuously for more than 3 minutes, Sensor will send an alarm (in Confirmed MODE) to platform. 642 +))) 619 619 620 -DDS75-LB use ER26500 + SPC1520 battery pack. See below link for detail information about the battery info and how to replace. 644 +((( 645 +(% style="color:red" %)**Note:** **After this alarm is send, sensor will consider a stop of water flow and count for another new event. So if water flow waste last for 1 hour, Sensor will keep sending alarm every 3 minutes.** 646 +))) 621 621 622 -[[**Battery Info & Power Consumption Analyze**>>http://wiki.dragino.com/xwiki/bin/view/Main/How%20to%20calculate%20the%20battery%20life%20of%20Dragino%20sensors%3F/]] . 648 +((( 649 +(% style="color:#4f81bd" %)**AT Command**(%%) to configure: 650 +))) 623 623 652 +* ((( 653 +AT+PTRIG=15,3 ~-~-> Set Stop duration: 15s, Alarm Timer: 3 minutes. 654 +))) 624 624 625 -= 5. OTA Firmware update = 656 +* ((( 657 +AT+ PTRIG=15,0 ~-~-> Default Value, disable water waste Alarm. 658 +))) 626 626 660 +((( 661 +(% style="color:#4f81bd" %)**Downlink Command**(%%) to configure: 662 +))) 627 627 628 -(% class="wikigeneratedid" %) 629 -User can change firmware DDS75-LB to: 664 +((( 665 +Command: **0xAA aa bb cc** 666 +))) 630 630 631 -* Change Frequency band/ region. 668 +((( 669 +AA: Command Type Code 670 +))) 632 632 633 -* Update with new features. 672 +((( 673 +aa: Stop duration 674 +))) 634 634 635 -* Fix bugs. 676 +((( 677 +bb cc: Alarm Timer 678 +))) 636 636 637 -Firmware and changelog can be downloaded from : **[[Firmware download link>>url:https://www.dropbox.com/sh/7la95mae0fn03xe/AACtzs-32m22TLb75B-iIr-Qa?dl=0]]** 680 +((( 681 +If user send 0xAA 0F 00 03: equal to AT+PTRIG=15,3 682 +))) 638 638 639 -Methods to Update Firmware: 640 640 641 - *(Recommandedway) OTA firmwareupdate via wireless:[[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/Firmware%20OTA%20Update%20for%20Sensors/>>url:http://wiki.dragino.com/xwiki/bin/view/Main/Firmware%20OTA%20Update%20for%20Sensors/]]685 +=== 3.3.5 Clear Flash Record === 642 642 643 -* Update through UART TTL interface. **[[Instruction>>url:http://wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H1.LoRaSTv4baseHardware]]**. 644 644 645 - =6.FAQ=688 +Feature: Clear flash storage for data log feature. 646 646 690 +(% style="color:blue" %)**AT Command: AT+CLRDTA** 647 647 648 -== 6.1 What is the frequency plan for DDS75-LB? == 692 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:500px" %) 693 +|=(% style="width: 157px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 169px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 174px;background-color:#D9E2F3;color:#0070C0" %)**Response** 694 +|(% style="width:157px" %)AT+CLRDTA|(% style="width:169px" %)Clear flash storage for data log feature.|Clear all stored sensor data… OK 649 649 696 +((( 697 +(% style="color:blue" %)**Downlink Command:** 698 +))) 650 650 651 -DDS75-LB use the same frequency as other Dragino products. User can see the detail from this link: [[Introduction>>doc:Main.End Device Frequency Band.WebHome||anchor="H1.Introduction"]] 700 +((( 701 +* **Example**: 0xA301 ~/~/ Same as AT+CLRDTA 702 +))) 652 652 653 653 654 -== 6.2 Can I use DDS75-LB in condensation environment? == 655 655 706 +=== 3.3.6 Set the calculate flag === 656 656 657 -DDS75-LB is not suitable to be used in condensation environment. Condensation on the DDS75-LB probe will affect the reading and always got 0. 658 658 709 +Feature: Set the calculate flag 659 659 660 - =7. TroubleShooting=711 +(% style="color:blue" %)**AT Command: AT+CALCFLAG** 661 661 662 -== 7.1 Why I can't join TTN V3 in US915 / AU915 bands? == 713 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:461px" %) 714 +|=(% style="width: 158px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 193px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 110px;background-color:#D9E2F3;color:#0070C0" %)**Response** 715 +|(% style="width:158px" %)AT+CALCFLAG =1|(% style="width:192px" %)Set the calculate flag to 1.|(% style="width:109px" %)OK 716 +|(% style="width:158px" %)AT+CALCFLAG =2|(% style="width:192px" %)Set the calculate flag to 2.|(% style="width:109px" %)OK 663 663 718 +(% style="color:blue" %)**Downlink Command:** 664 664 665 - Itis due to channelmapping. Pleaseseebelowlink:[[Frequencyband>>doc:Main.LoRaWAN Communication Debug.WebHome||anchor="H2.NoticeofUS9152FCN4702FAU915Frequencyband"]]720 +* **Example**: 0XA501 ~/~/ Same as AT+CALCFLAG =1 666 666 722 +=== 3.3.7 Set count number === 667 667 668 -== 7.2 AT Command input doesn't work == 669 669 725 +Feature: Manually set the count number 670 670 671 - In the case if user can see the console output but can't type input to the device. Please check if you already include the(% style="color:blue" %)**ENTER**(%%)while sendingout the command. Some serial tool doesn't send (% style="color:blue"%)**ENTER**(%%) while press the send key, user need to add ENTER in their string.727 +(% style="color:blue" %)**AT Command: AT+SETCNT** 672 672 729 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:479px" %) 730 +|=(% style="width: 160px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 223px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 96px;background-color:#D9E2F3;color:#0070C0" %)**Response** 731 +|(% style="width:160px" %)AT+ SETCNT =0|(% style="width:221px" %)Set the count number to 0.|(% style="width:95px" %)OK 732 +|(% style="width:160px" %)AT+ SETCNT =100|(% style="width:221px" %)Set the count number to 100.|(% style="width:95px" %)OK 673 673 674 - ==7.3 Why doeshesensorreadingshow0or "No sensor" ==734 +(% style="color:blue" %)**Downlink Command:** 675 675 736 +* **Example**: 0xA6000001 ~/~/ Same as AT+ SETCNT =1 676 676 677 - ~1.The measurementobjectisveryclosetothesensor,but in the blindspotofthesensor.738 +* **Example**: 0xA6000064 ~/~/ Same as AT+ SETCNT =100 678 678 679 - 2. Sensorwiringis disconnected740 +=== 3.3.8 Set Interrupt Mode === 680 680 681 -3. Not using the correct decoder 682 682 743 +Feature, Set Interrupt mode for PA8 of pin. 683 683 684 - ==5.4AbnormalreadingsThegap betweenmultiplereadingsistoo largeor the gapbetween the readings andtheactualvalueistoolarge ==745 +When AT+INTMOD=0 is set, PA8 is used as a digital input port. 685 685 747 +(% style="color:blue" %)**AT Command: AT+INTMOD** 686 686 687 -1) Please check if there is something on the probe affecting its measurement (condensed water, volatile oil, etc.) 749 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %) 750 +|=(% style="width: 155px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 197px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 158px;background-color:#D9E2F3;color:#0070C0" %)**Response** 751 +|(% style="width:154px" %)AT+INTMOD=?|(% style="width:196px" %)Show current interrupt mode|(% style="width:157px" %)((( 752 +0 753 +OK 754 +the mode is 0 =Disable Interrupt 755 +))) 756 +|(% style="width:154px" %)AT+INTMOD=2|(% style="width:196px" %)((( 757 +Set Transmit Interval 758 +0. (Disable Interrupt), 759 +~1. (Trigger by rising and falling edge) 760 +2. (Trigger by falling edge) 761 +3. (Trigger by rising edge) 762 +)))|(% style="width:157px" %)OK 688 688 689 - 2)Doesitchangewith temperature,temperaturewill affectitsmeasurement764 +(% style="color:blue" %)**Downlink Command: 0x06** 690 690 691 - 3) If abnormal dataoccurs, you canturnon DEBUG mode,Pleaseuse downlinkorATCOMMANtoenter DEBUG mode.766 +Format: Command Code (0x06) followed by 3 bytes. 692 692 693 - downlinkcommand:(%style="color:blue"%)**F101**(%%),AT command:(%style="color:blue"%)**AT+DDEBUG=1**768 +This means that the interrupt mode of the end node is set to 0x000003=3 (rising edge trigger), and the type code is 06. 694 694 695 - 4)After entering the debugmode,itwill send20piecesofdataatatime,andyoucan senditsuplinktous for analysis770 +* Example 1: Downlink Payload: 06000000 ~/~/ Turn off interrupt mode 696 696 697 - [[image:image-20230113135125-2.png||height="136"width="1057"]]772 +* Example 2: Downlink Payload: 06000003 ~/~/ Set the interrupt mode to rising edge trigger 698 698 774 +=== 3.3.9 Set work mode === 699 699 700 -Its original payload will be longer than other data. Even though it is being parsed, it can be seen that it is abnormal data. 701 701 702 - Please sendthedata tous forcheck.777 +Feature: Manually set the work mode 703 703 704 704 705 - =8. OrderInfo=780 +(% style="color:blue" %)**AT Command: AT+MOD** 706 706 782 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:463px" %) 783 +|=(% style="width: 162px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 193px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 108px;background-color:#D9E2F3;color:#0070C0" %)**Response** 784 +|(% style="width:162px" %)AT+MOD=0|(% style="width:191px" %)Set the work mode to 0.|(% style="width:106px" %)OK 785 +|(% style="width:162px" %)AT+MOD=1|(% style="width:191px" %)Set the work mode to 1|(% style="width:106px" %)OK 707 707 708 - Part Number:(% style="color:blue" %)**DDS75-LB-XXX**787 +(% style="color:blue" %)**Downlink Command:** 709 709 710 - (%style="color:red"%)**XXX**(%%):**Thedefaultfrequencyband**789 +* **Example: **0x0A00 ~/~/ Same as AT+MOD=0 711 711 791 +* **Example:** 0x0A01 ~/~/ Same as AT+MOD=1 792 + 793 += 4. Battery & Power Consumption = 794 + 795 + 796 +SW3L-LB use ER26500 + SPC1520 battery pack. See below link for detail information about the battery info and how to replace. 797 + 798 +[[**Battery Info & Power Consumption Analyze**>>http://wiki.dragino.com/xwiki/bin/view/Main/How%20to%20calculate%20the%20battery%20life%20of%20Dragino%20sensors%3F/]] . 799 + 800 + 801 += 5. OTA Firmware update = 802 + 803 + 804 +(% class="wikigeneratedid" %) 805 +User can change firmware SW3L-LB to: 806 + 807 +* Change Frequency band/ region. 808 + 809 +* Update with new features. 810 + 811 +* Fix bugs. 812 + 813 +Firmware and changelog can be downloaded from : **[[Firmware download link>>url:https://www.dropbox.com/sh/kwqv57tp6pejias/AAAopYMATh1GM6fZ-VRCLrpDa?dl=0]]** 814 + 815 +Methods to Update Firmware: 816 + 817 +* (Recommanded way) OTA firmware update via wireless: [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/Firmware%20OTA%20Update%20for%20Sensors/>>url:http://wiki.dragino.com/xwiki/bin/view/Main/Firmware%20OTA%20Update%20for%20Sensors/]] 818 + 819 +* Update through UART TTL interface. **[[Instruction>>url:http://wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H1.LoRaSTv4baseHardware]]**. 820 + 821 += 6. FAQ = 822 + 823 +== 6.1 AT Commands input doesn't work == 824 + 825 + 826 +In the case if user can see the console output but can't type input to the device. Please check if you already include the (% style="color:green" %)**ENTER**(%%) while sending out the command. Some serial tool doesn't send (% style="color:green" %)**ENTER**(%%) while press the send key, user need to add ENTER in their string. 827 + 828 + 829 += 7. Order Info = 830 + 831 + 832 +Part Number: (% style="color:blue" %)**SW3L-LB-XXX-YYY** 833 + 834 +(% style="color:red" %)**XXX**(%%): The default frequency band 835 + 712 712 * (% style="color:red" %)**AS923**(%%): LoRaWAN AS923 band 713 713 714 714 * (% style="color:red" %)**AU915**(%%): LoRaWAN AU915 band ... ... @@ -725,15 +725,43 @@ 725 725 726 726 * (% style="color:red" %)**CN470**(%%): LoRaWAN CN470 band 727 727 852 +((( 853 +(% style="color:blue" %)**YYY**(%%): Flow Sensor Model: 854 +))) 728 728 856 +((( 857 + **004:** DW-004 Flow Sensor: diameter: G1/2” / DN15. 450 pulse = 1 L 858 +))) 729 729 860 +((( 861 + **006:** DW-006 Flow Sensor: diameter: G3/4” / DN20. 390 pulse = 1 L 862 +))) 730 730 731 -= 9. Packing Info = 864 +((( 865 + **010:** DW-010 Flow Sensor: diameter: G 1” / DN25. 64 pulse = 1 L 866 +))) 732 732 868 +* ((( 869 +calculate flag=0: for SW3L-004 Flow Sensor: 450 pulse = 1 L 870 +))) 733 733 872 +* ((( 873 +calculate flag=1: for SW3L-006 Flow Sensor: 390 pulse = 1 L 874 +))) 875 + 876 +* ((( 877 +calculate flag=2: for SW3L-010 Flow Sensor: 64 pulse = 1 L 878 + 879 + 880 + 881 +))) 882 + 883 += 8. Packing Info = 884 + 885 + 734 734 (% style="color:#037691" %)**Package Includes**: 735 735 736 -* DDS75-LB LoRaWANDistance DetectionSensorx 1888 +* SW3L-LB LoRaWAN Flow Sensor 737 737 738 738 (% style="color:#037691" %)**Dimension and weight**: 739 739 ... ... @@ -745,12 +745,9 @@ 745 745 746 746 * Weight / pcs : g 747 747 900 += 9. Support = 748 748 749 749 750 - 751 -= 10. Support = 752 - 753 - 754 754 * Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule. 755 755 756 756 * Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[Support@dragino.cc>>mailto:Support@dragino.cc]].