Changes for page DS20L -- LoRaWAN Smart Distance Detector User Manual 01
Last modified by Mengting Qiu on 2023/12/14 11:15
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -22,13 +22,13 @@ 22 22 23 23 It detects the distance(% style="color:blue" %)** between the measured object and the sensor**(%%), and uploads the value via wireless to LoRaWAN IoT Server. 24 24 25 -The LoRa wireless technology used in S W3L-LB allows device to send data and reach extremely long ranges at low data-rates. It provides ultra-long range spread spectrum communication and high interference immunity whilst minimizing current consumption.25 +The LoRa wireless technology used in DDS75-LB allows device to send data and reach extremely long ranges at low data-rates. It provides ultra-long range spread spectrum communication and high interference immunity whilst minimizing current consumption. 26 26 27 -S W3L-LB (% style="color:blue" %)**supports BLE configure**(%%) and (% style="color:blue" %)**wireless OTA update**(%%) which make user easy to use.27 +DDS75-LB (% style="color:blue" %)**supports BLE configure**(%%) and (% style="color:blue" %)**wireless OTA update**(%%) which make user easy to use. 28 28 29 -S W3L-LB is powered by (% style="color:blue" %)**8500mAh Li-SOCI2 battery**(%%), it is designed for long term use up to 5 years.29 +DDS75-LB is powered by (% style="color:blue" %)**8500mAh Li-SOCI2 battery**(%%), it is designed for long term use up to 5 years. 30 30 31 -Each S W3L-LB is pre-load with a set of unique keys for LoRaWAN registrations, register these keys to local LoRaWAN server and it will auto connect after power on.31 +Each DDS75-LB is pre-load with a set of unique keys for LoRaWAN registrations, register these keys to local LoRaWAN server and it will auto connect after power on. 32 32 33 33 [[image:image-20230612170943-2.png||height="525" width="912"]] 34 34 ... ... @@ -50,36 +50,10 @@ 50 50 * IP66 Waterproof Enclosure 51 51 * 8500mAh Battery for long term use 52 52 53 + 53 53 == 1.3 Specification == 54 54 55 55 56 -(% style="color:#037691" %)**Rated environmental conditions:** 57 - 58 -(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:500px" %) 59 -|(% style="background-color:#d9e2f3; color:#0070c0; width:163px" %)**Item**|(% style="background-color:#d9e2f3; color:#0070c0; width:90px" %)((( 60 -**Minimum value** 61 -)))|(% style="background-color:#d9e2f3; color:#0070c0; width:70px" %)((( 62 -**Typical value** 63 -)))|(% style="background-color:#d9e2f3; color:#0070c0; width:87px" %)((( 64 -**Maximum value** 65 -)))|(% style="background-color:#d9e2f3; color:#0070c0; width:40px" %)**Unit**|(% style="background-color:#d9e2f3; color:#0070c0; width:50px" %)**Remarks** 66 -|(% style="width:174px" %)Storage temperature|(% style="width:86px" %)-25|(% style="width:66px" %)25|(% style="width:90px" %)80|(% style="width:48px" %)℃|(% style="width:203px" %) 67 -|(% style="width:174px" %)Storage humidity|(% style="width:86px" %) |(% style="width:66px" %)65%|(% style="width:90px" %)90%|(% style="width:48px" %)RH|(% style="width:203px" %)(1) 68 -|(% style="width:174px" %)Operating temperature|(% style="width:86px" %)-15|(% style="width:66px" %)25|(% style="width:90px" %)60|(% style="width:48px" %)℃|(% style="width:203px" %) 69 -|(% style="width:174px" %)Working humidity|(% style="width:86px" %)((( 70 - 71 - 72 - 73 -)))|(% style="width:66px" %)65%|(% style="width:90px" %)80%|(% style="width:48px" %)RH|(% style="width:203px" %)(1) 74 - 75 -((( 76 -**Remarks: (1) a. When the ambient temperature is 0-39 ℃, the maximum humidity is 90% (non-condensing); ** 77 - 78 -**~ b. When the ambient temperature is 40-50 ℃, the highest humidity is the highest humidity in the natural world at the current temperature (no condensation)** 79 - 80 - 81 -))) 82 - 83 83 (% style="color:#037691" %)**Common DC Characteristics:** 84 84 85 85 * Supply Voltage: built in 8500mAh Li-SOCI2 battery , 2.5v ~~ 3.6v ... ... @@ -105,20 +105,50 @@ 105 105 * Sleep Mode: 5uA @ 3.3v 106 106 * LoRa Transmit Mode: 125mA @ 20dBm, 82mA @ 14dBm 107 107 108 -== 1.4 Effective measurement range Reference beam pattern == 109 109 110 110 111 - **~1.Thetestedobject is a white cylindrical tubemadeof PVC, withaheight of 100cm anda diameterof7.5cm.**84 +== 1.4 Rated environmental conditions == 112 112 86 + 87 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:500px" %) 88 +|(% style="background-color:#d9e2f3; color:#0070c0; width:163px" %)**Item**|(% style="background-color:#d9e2f3; color:#0070c0; width:90px" %)((( 89 +**Minimum value** 90 +)))|(% style="background-color:#d9e2f3; color:#0070c0; width:70px" %)((( 91 +**Typical value** 92 +)))|(% style="background-color:#d9e2f3; color:#0070c0; width:87px" %)((( 93 +**Maximum value** 94 +)))|(% style="background-color:#d9e2f3; color:#0070c0; width:40px" %)**Unit**|(% style="background-color:#d9e2f3; color:#0070c0; width:50px" %)**Remarks** 95 +|(% style="width:174px" %)Storage temperature|(% style="width:86px" %)-25|(% style="width:66px" %)25|(% style="width:90px" %)80|(% style="width:48px" %)℃|(% style="width:203px" %) 96 +|(% style="width:174px" %)Storage humidity|(% style="width:86px" %) |(% style="width:66px" %)65%|(% style="width:90px" %)90%|(% style="width:48px" %)RH|(% style="width:203px" %)(1) 97 +|(% style="width:174px" %)Operating temperature|(% style="width:86px" %)-15|(% style="width:66px" %)25|(% style="width:90px" %)60|(% style="width:48px" %)℃|(% style="width:203px" %) 98 +|(% style="width:174px" %)Working humidity|(% style="width:86px" %)((( 99 + 100 + 101 + 102 +)))|(% style="width:66px" %)65%|(% style="width:90px" %)80%|(% style="width:48px" %)RH|(% style="width:203px" %)(1) 103 + 104 +((( 105 +(% style="color:red" %)**Remarks: (1) a. When the ambient temperature is 0-39 ℃, the maximum humidity is 90% (non-condensing); ** 106 + 107 +(% style="color:red" %)** b. When the ambient temperature is 40-50 ℃, the highest humidity is the highest humidity in the natural world at the current temperature (no condensation)** 108 + 109 + 110 +))) 111 + 112 +== 1.5 Effective measurement range Reference beam pattern == 113 + 114 + 115 +(% style="color:blue" %)**1. The tested object is a white cylindrical tube made of PVC, with a height of 100cm and a diameter of 7.5cm.** 116 + 113 113 [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDDS75%20-%20LoRaWAN%20Distance%20Detection%20Sensor%20User%20Manual/WebHome/1654852253176-749.png?rev=1.1||alt="1654852253176-749.png"]] 114 114 115 115 116 -**2. The object to be tested is a "corrugated cardboard box" perpendicular to the central axis of 0 °, and the length * width is 60cm * 50cm.** 120 +(% style="color:blue" %)**2. The object to be tested is a "corrugated cardboard box" perpendicular to the central axis of 0 °, and the length * width is 60cm * 50cm.** 117 117 118 118 [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDDS75%20-%20LoRaWAN%20Distance%20Detection%20Sensor%20User%20Manual/WebHome/1654852175653-550.png?rev=1.1||alt="1654852175653-550.png"]] 119 119 120 120 121 -== 1. 5Applications ==125 +== 1.6 Applications == 122 122 123 123 124 124 * Horizontal distance measurement ... ... @@ -131,15 +131,17 @@ 131 131 * Sewer 132 132 * Bottom water level monitoring 133 133 134 -== 1.6 Sleep mode and working mode == 135 135 136 136 140 +== 1.7 Sleep mode and working mode == 141 + 142 + 137 137 (% style="color:blue" %)**Deep Sleep Mode: **(%%)Sensor doesn't have any LoRaWAN activate. This mode is used for storage and shipping to save battery life. 138 138 139 139 (% style="color:blue" %)**Working Mode:** (%%)In this mode, Sensor will work as LoRaWAN Sensor to Join LoRaWAN network and send out sensor data to server. Between each sampling/tx/rx periodically, sensor will be in IDLE mode), in IDLE mode, sensor has the same power consumption as Deep Sleep mode. 140 140 141 141 142 -== 1. 7Button & LEDs ==148 +== 1.8 Button & LEDs == 143 143 144 144 145 145 [[image:Main.User Manual for LoRaWAN End Nodes.D20-LBD22-LBD23-LB_LoRaWAN_Temperature_Sensor_User_Manual.WebHome@1675071855856-879.png]] ... ... @@ -158,9 +158,11 @@ 158 158 ))) 159 159 |(% style="width:167px" %)Fast press ACT 5 times.|(% style="width:117px" %)Deactivate Device|(% style="width:225px" %)(% style="color:red" %)**Red led**(%%) will solid on for 5 seconds. Means device is in Deep Sleep Mode. 160 160 161 -== 1.8 BLE connection == 162 162 163 163 169 +== 1.9 BLE connection == 170 + 171 + 164 164 DDS75-LB support BLE remote configure. 165 165 166 166 ... ... @@ -173,16 +173,14 @@ 173 173 If there is no activity connection on BLE in 60 seconds, sensor will shut down BLE module to enter low power mode. 174 174 175 175 176 -== 1. 9Pin Definitions ==184 +== 1.10 Pin Definitions == 177 177 178 178 [[image:image-20230523174230-1.png]] 179 179 180 180 181 -== == 189 +== 1.11 Mechanical == 182 182 183 -== 2.10 Mechanical == 184 184 185 - 186 186 [[image:Main.User Manual for LoRaWAN End Nodes.D20-LBD22-LBD23-LB_LoRaWAN_Temperature_Sensor_User_Manual.WebHome@1675143884058-338.png]] 187 187 188 188 ... ... @@ -192,7 +192,7 @@ 192 192 [[image:Main.User Manual for LoRaWAN End Nodes.D20-LBD22-LBD23-LB_LoRaWAN_Temperature_Sensor_User_Manual.WebHome@1675143909447-639.png]] 193 193 194 194 195 -**Probe Mechanical:** 201 +(% style="color:blue" %)**Probe Mechanical:** 196 196 197 197 198 198 [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDDS75%20-%20LoRaWAN%20Distance%20Detection%20Sensor%20User%20Manual/WebHome/image-20220610172003-1.png?rev=1.1||alt="image-20220610172003-1.png"]] ... ... @@ -268,20 +268,13 @@ 268 268 269 269 270 270 ((( 271 -((( 272 272 DDS75-LB will uplink payload via LoRaWAN with below payload format: 273 273 ))) 274 274 275 275 ((( 276 -Uplink payload includes in total 4 bytes. 277 -Payload for firmware version v1.1.4. . Before v1.1.3, there is on two fields: BAT and Distance 281 +Uplink payload includes in total 8 bytes. 278 278 ))) 279 -))) 280 280 281 -((( 282 - 283 -))) 284 - 285 285 (% border="1" cellspacing="5" style="background-color:#f2f2f2; width:510px" %) 286 286 |=(% style="width: 62.5px;background-color:#D9E2F3;color:#0070C0" %)((( 287 287 **Size(bytes)** ... ... @@ -321,12 +321,14 @@ 321 321 322 322 323 323 * If the sensor value is 0x0000, it means system doesn't detect ultrasonic sensor. 324 -* If the sensor value lower than 0x0118 (280mm), the sensor value will be invalid. Since v1.1.4, all value lower than 280mm will be set to 0x0014(20mm) which means the value is invalid.323 +* If the sensor value lower than 0x0118 (280mm), the sensor value will be invalid. All value lower than 280mm will be set to 0x0014(20mm) which means the value is invalid. 325 325 325 + 326 + 326 326 === 2.3.3 Interrupt Pin === 327 327 328 328 329 -This data field shows if this packet is generated by interrupt or not. [[Click here>>||anchor="H3.3 A0SetInterruptMode"]] for the hardware and software set up.330 +This data field shows if this packet is generated by interrupt or not. [[Click here>>||anchor="H3.3.2SetInterruptMode"]] for the hardware and software set up. 330 330 331 331 **Example:** 332 332 ... ... @@ -346,9 +346,7 @@ 346 346 347 347 If payload is: FF3FH : (FF3F & FC00 == 1) , temp = (FF3FH - 65536)/10 = -19.3 degrees. 348 348 349 -(% style="color:red" %)**Note: DS18B20 feature is supported in the hardware version > v1.3 which made since early of 2021.** 350 350 351 - 352 352 === 2.3.5 Sensor Flag === 353 353 354 354 ... ... @@ -378,7 +378,7 @@ 378 378 == 2.4 Uplink Interval == 379 379 380 380 381 -The DDS75-LB by default uplink the sensor data every 20 minutes. User can change this interval by AT Command or LoRaWAN Downlink Command. See this link: [[Change Uplink Interval>> doc:Main.End Device AT Commands and Downlink Command.WebHome||anchor="H4.1ChangeUplinkInterval"]]380 +The DDS75-LB by default uplink the sensor data every 20 minutes. User can change this interval by AT Command or LoRaWAN Downlink Command. See this link: [[Change Uplink Interval>>||anchor="H3.3.1SetTransmitIntervalTime"]] 382 382 383 383 384 384 == 2.5 Show Data in DataCake IoT Server == ... ... @@ -388,9 +388,6 @@ 388 388 [[DATACAKE>>url:https://datacake.co/]] provides a human friendly interface to show the sensor data, once we have data in TTN, we can use [[DATACAKE>>url:https://datacake.co/]] to connect to TTN and see the data in DATACAKE. Below are the steps: 389 389 ))) 390 390 391 -((( 392 - 393 -))) 394 394 395 395 ((( 396 396 (% style="color:blue" %)**Step 1**(%%)**: Be sure that your device is programmed and properly connected to the network at this time.** ... ... @@ -423,19 +423,19 @@ 423 423 == 2.6 Datalog Feature == 424 424 425 425 426 -Datalog Feature is to ensure IoT Server can get all sampling data from Sensor even if the LoRaWAN network is down. For each sampling, S W3L-LB will store the reading for future retrieving purposes.422 +Datalog Feature is to ensure IoT Server can get all sampling data from Sensor even if the LoRaWAN network is down. For each sampling, DDS75-LB will store the reading for future retrieving purposes. 427 427 428 428 429 429 === 2.6.1 Ways to get datalog via LoRaWAN === 430 430 431 431 432 -Set PNACKMD=1, S W3L-LB will wait for ACK for every uplink, when there is no LoRaWAN network,SW3L-LB will mark these records with non-ack messages and store the sensor data, and it will send all messages (10s interval) after the network recovery.428 +Set PNACKMD=1, DDS75-LB will wait for ACK for every uplink, when there is no LoRaWAN network,DDS75-LB will mark these records with non-ack messages and store the sensor data, and it will send all messages (10s interval) after the network recovery. 433 433 434 434 * ((( 435 -a) S W3L-LB will do an ACK check for data records sending to make sure every data arrive server.431 +a) DDS75-LB will do an ACK check for data records sending to make sure every data arrive server. 436 436 ))) 437 437 * ((( 438 -b) S W3L-LB will send data in **CONFIRMED Mode** when PNACKMD=1, but SW3L-LB won't re-transmit the packet if it doesn't get ACK, it will just mark it as a NONE-ACK message. In a future uplink if SW3L-LB gets a ACK, SW3L-LB will consider there is a network connection and resend all NONE-ACK messages.434 +b) DDS75-LB will send data in **CONFIRMED Mode** when PNACKMD=1, but DDS75-LB won't re-transmit the packet if it doesn't get ACK, it will just mark it as a NONE-ACK message. In a future uplink if DDS75-LB gets a ACK, DDS75-LB will consider there is a network connection and resend all NONE-ACK messages. 439 439 ))) 440 440 441 441 Below is the typical case for the auto-update datalog feature (Set PNACKMD=1) ... ... @@ -446,7 +446,7 @@ 446 446 === 2.6.2 Unix TimeStamp === 447 447 448 448 449 -S W3L-LB uses Unix TimeStamp format based on445 +DDS75-LB uses Unix TimeStamp format based on 450 450 451 451 [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/WebHome/image-20220523001219-11.png?width=627&height=97&rev=1.1||alt="图片-20220523001219-11.png" height="97" width="627"]] 452 452 ... ... @@ -465,7 +465,7 @@ 465 465 466 466 User need to set (% style="color:blue" %)**SYNCMOD=1**(%%) to enable sync time via MAC command. 467 467 468 -Once S W3L-LB Joined LoRaWAN network, it will send the MAC command (DeviceTimeReq) and the server will reply with (DeviceTimeAns) to send the current time to SW3L-LB. If SW3L-LB fails to get the time from the server, SW3L-LB will use the internal time and wait for next time request (AT+SYNCTDC to set the time request period, default is 10 days).464 +Once DDS75-LB Joined LoRaWAN network, it will send the MAC command (DeviceTimeReq) and the server will reply with (DeviceTimeAns) to send the current time to DDS75-LB. If DDS75-LB fails to get the time from the server, DDS75-LB will use the internal time and wait for next time request (AT+SYNCTDC to set the time request period, default is 10 days). 469 469 470 470 (% style="color:red" %)**Note: LoRaWAN Server need to support LoRaWAN v1.0.3(MAC v1.0.3) or higher to support this MAC command feature, Chirpstack,TTN V3 v3 and loriot support but TTN V3 v2 doesn't support. If server doesn't support this command, it will through away uplink packet with this command, so user will lose the packet with time request for TTN V3 v2 if SYNCMOD=1.** 471 471 ... ... @@ -493,7 +493,7 @@ 493 493 ))) 494 494 495 495 ((( 496 -Uplink Internal =5s,means S W3L-LB will send one packet every 5s. range 5~~255s.492 +Uplink Internal =5s,means DDS75-LB will send one packet every 5s. range 5~~255s. 497 497 ))) 498 498 499 499 ... ... @@ -500,17 +500,17 @@ 500 500 == 2.7 Frequency Plans == 501 501 502 502 503 -The S W3L-LB uses OTAA mode and below frequency plans by default. If user want to use it with different frequency plan, please refer the AT command sets.499 +The DDS75-LB uses OTAA mode and below frequency plans by default. If user want to use it with different frequency plan, please refer the AT command sets. 504 504 505 505 [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20Frequency%20Band/>>http://wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20Frequency%20Band/]] 506 506 507 507 508 -= 3. Configure S W3L-LB =504 += 3. Configure DDS75-LB = 509 509 510 510 == 3.1 Configure Methods == 511 511 512 512 513 -S W3L-LB supports below configure method:509 +DDS75-LB supports below configure method: 514 514 515 515 * AT Command via Bluetooth Connection (**Recommended**): [[BLE Configure Instruction>>http://wiki.dragino.com/xwiki/bin/view/Main/BLE%20Bluetooth%20Remote%20Configure/]]. 516 516 ... ... @@ -518,6 +518,8 @@ 518 518 519 519 * LoRaWAN Downlink. Instruction for different platforms: See [[IoT LoRaWAN Server>>http://wiki.dragino.com/xwiki/bin/view/Main/]] section. 520 520 517 + 518 + 521 521 == 3.2 General Commands == 522 522 523 523 ... ... @@ -532,10 +532,10 @@ 532 532 [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/>>http://wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/]] 533 533 534 534 535 -== 3.3 Commands special design for S W3L-LB ==533 +== 3.3 Commands special design for DDS75-LB == 536 536 537 537 538 -These commands only valid for S W3L-LB, as below:536 +These commands only valid for DDS75-LB, as below: 539 539 540 540 541 541 === 3.3.1 Set Transmit Interval Time === ... ... @@ -578,261 +578,143 @@ 578 578 ))) 579 579 * ((( 580 580 Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds 581 -))) 582 582 583 -=== 3.3.2 Quit AT Command === 584 584 585 - 586 -Feature: Quit AT Command mode, so user needs to input the password again before using AT Commands. 587 - 588 -(% style="color:blue" %)**AT Command: AT+DISAT** 589 - 590 -(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:452px" %) 591 -|=(% style="width: 155px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 198px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 99px;background-color:#D9E2F3;color:#0070C0" %)**Response** 592 -|(% style="width:155px" %)AT+DISAT|(% style="width:198px" %)Quit AT Commands mode|(% style="width:96px" %)OK 593 - 594 -(% style="color:blue" %)**Downlink Command:** 595 - 596 -No downlink command for this feature. 597 - 598 - 599 -=== 3.3.3 Get Device Status === 600 - 601 - 602 -Send a LoRaWAN downlink to ask device send Alarm settings. 603 - 604 -(% style="color:blue" %)**Downlink Payload: **(%%)0x26 01 605 - 606 -Sensor will upload Device Status via FPORT=5. See payload section for detail. 607 - 608 - 609 -=== 3.3.4 Alarm for continuously water flow === 610 - 611 - 612 -((( 613 -This feature is to monitor and send Alarm for continuously water flow. 581 + 614 614 ))) 615 615 616 -((( 617 -Example case is for Toilet water monitoring, if some one push toilet button, the toilet will have water flow. If the toilet button has broken and can't returned to original state, the water flow will keep for hours or days which cause huge waste for water. 618 -))) 584 +=== 3.3.2 Set Interrupt Mode === 619 619 620 -((( 621 -To monitor this faulty and send alarm, there are two settings: 622 -))) 623 623 624 -* ((( 625 -(% style="color:#4f81bd" %)**Stop Duration: Unit: Second** 626 -))) 587 +Feature, Set Interrupt mode for PA8 of pin. 627 627 628 -((( 629 -Default: 15s, If SW3L-LB didn't see any water flow in 15s, SW3L-LB will consider stop of water flow event. 630 -))) 589 +When AT+INTMOD=0 is set, PA8 is used as a digital input port. 631 631 632 -* ((( 633 -(% style="color:#4f81bd" %)**Alarm Timer: Units: Minute; Default 0 minutes (means Alarm disable)** 634 -))) 591 +(% style="color:blue" %)**AT Command: AT+INTMOD** 635 635 636 -((( 637 -**Example:** 3 minutes, if SW3L-LB detect a start of water flow event and didn't detect a stop event within Alarm timer, SW3L-LB will send an Alarm to indicate a water flow abnormal alarm. 593 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %) 594 +|=(% style="width: 155px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 197px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 158px;background-color:#D9E2F3;color:#0070C0" %)**Response** 595 +|(% style="width:154px" %)AT+INTMOD=?|(% style="width:196px" %)Show current interrupt mode|(% style="width:157px" %)((( 596 +0 597 +OK 598 +the mode is 0 =Disable Interrupt 638 638 ))) 600 +|(% style="width:154px" %)AT+INTMOD=2|(% style="width:196px" %)((( 601 +Set Transmit Interval 602 +0. (Disable Interrupt), 603 +~1. (Trigger by rising and falling edge) 604 +2. (Trigger by falling edge) 605 +3. (Trigger by rising edge) 606 +)))|(% style="width:157px" %)OK 639 639 640 -((( 641 -So for example, If we set stop duration=15s and Alarm Timer=3minutes. If the toilet water flow continuously for more than 3 minutes, Sensor will send an alarm (in Confirmed MODE) to platform. 642 -))) 608 +(% style="color:blue" %)**Downlink Command: 0x06** 643 643 644 -((( 645 -(% style="color:red" %)**Note:** **After this alarm is send, sensor will consider a stop of water flow and count for another new event. So if water flow waste last for 1 hour, Sensor will keep sending alarm every 3 minutes.** 646 -))) 610 +Format: Command Code (0x06) followed by 3 bytes. 647 647 648 -((( 649 -(% style="color:#4f81bd" %)**AT Command**(%%) to configure: 650 -))) 612 +This means that the interrupt mode of the end node is set to 0x000003=3 (rising edge trigger), and the type code is 06. 651 651 652 -* ((( 653 -AT+PTRIG=15,3 ~-~-> Set Stop duration: 15s, Alarm Timer: 3 minutes. 654 -))) 614 +* Example 1: Downlink Payload: 06000000 ~/~/ Turn off interrupt mode 655 655 656 -* ((( 657 -AT+ PTRIG=15,0 ~-~-> Default Value, disable water waste Alarm. 658 -))) 616 +* Example 2: Downlink Payload: 06000003 ~/~/ Set the interrupt mode to rising edge trigger 659 659 660 -((( 661 -(% style="color:#4f81bd" %)**Downlink Command**(%%) to configure: 662 -))) 663 663 664 -((( 665 -Command: **0xAA aa bb cc** 666 -))) 667 667 668 -((( 669 -AA: Command Type Code 670 -))) 620 += 4. Battery & Power Consumption = 671 671 672 -((( 673 -aa: Stop duration 674 -))) 675 675 676 -((( 677 -bb cc: Alarm Timer 678 -))) 623 +DDS75-LB use ER26500 + SPC1520 battery pack. See below link for detail information about the battery info and how to replace. 679 679 680 -((( 681 -If user send 0xAA 0F 00 03: equal to AT+PTRIG=15,3 682 -))) 625 +[[**Battery Info & Power Consumption Analyze**>>http://wiki.dragino.com/xwiki/bin/view/Main/How%20to%20calculate%20the%20battery%20life%20of%20Dragino%20sensors%3F/]] . 683 683 684 684 685 -= ==3.3.5ClearFlash Record ===628 += 5. OTA Firmware update = 686 686 687 687 688 -Feature: Clear flash storage for data log feature. 631 +(% class="wikigeneratedid" %) 632 +User can change firmware DDS75-LB to: 689 689 690 - (%style="color:blue"%)**AT Command:AT+CLRDTA**634 +* Change Frequency band/ region. 691 691 692 -(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:500px" %) 693 -|=(% style="width: 157px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 169px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 174px;background-color:#D9E2F3;color:#0070C0" %)**Response** 694 -|(% style="width:157px" %)AT+CLRDTA|(% style="width:169px" %)Clear flash storage for data log feature.|Clear all stored sensor data… OK 636 +* Update with new features. 695 695 696 -((( 697 -(% style="color:blue" %)**Downlink Command:** 698 -))) 638 +* Fix bugs. 699 699 700 -((( 701 -* **Example**: 0xA301 ~/~/ Same as AT+CLRDTA 702 -))) 640 +Firmware and changelog can be downloaded from : **[[Firmware download link>>url:https://www.dropbox.com/sh/7la95mae0fn03xe/AACtzs-32m22TLb75B-iIr-Qa?dl=0]]** 703 703 642 +Methods to Update Firmware: 704 704 644 +* (Recommanded way) OTA firmware update via wireless: [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/Firmware%20OTA%20Update%20for%20Sensors/>>url:http://wiki.dragino.com/xwiki/bin/view/Main/Firmware%20OTA%20Update%20for%20Sensors/]] 705 705 706 - ===3.3.6 Set thecalculateg ===646 +* Update through UART TTL interface: **[[Instruction>>url:http://wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H1.LoRaSTv4baseHardware]]**. 707 707 708 708 709 -Feature: Set the calculate flag 710 710 711 - (% style="color:blue"%)**ATCommand: AT+CALCFLAG**650 += 6. FAQ = 712 712 713 -(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:461px" %) 714 -|=(% style="width: 158px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 193px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 110px;background-color:#D9E2F3;color:#0070C0" %)**Response** 715 -|(% style="width:158px" %)AT+CALCFLAG =1|(% style="width:192px" %)Set the calculate flag to 1.|(% style="width:109px" %)OK 716 -|(% style="width:158px" %)AT+CALCFLAG =2|(% style="width:192px" %)Set the calculate flag to 2.|(% style="width:109px" %)OK 652 +== 6.1 What is the frequency plan for DDS75-LB? == 717 717 718 -(% style="color:blue" %)**Downlink Command:** 719 719 720 - ***Example**:0XA501~/~/SameasAT+CALCFLAG=1655 +DDS75-LB use the same frequency as other Dragino products. User can see the detail from this link: [[Introduction>>doc:Main.End Device Frequency Band.WebHome||anchor="H1.Introduction"]] 721 721 722 -=== 3.3.7 Set count number === 723 723 658 +== 6.2 Can I use DDS75-LB in condensation environment? == 724 724 725 -Feature: Manually set the count number 726 726 727 - (%style="color:blue"%)**ATCommand:AT+SETCNT**661 +DDS75-LB is not suitable to be used in condensation environment. Condensation on the DDS75-LB probe will affect the reading and always got 0. 728 728 729 -(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:479px" %) 730 -|=(% style="width: 160px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 223px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 96px;background-color:#D9E2F3;color:#0070C0" %)**Response** 731 -|(% style="width:160px" %)AT+ SETCNT =0|(% style="width:221px" %)Set the count number to 0.|(% style="width:95px" %)OK 732 -|(% style="width:160px" %)AT+ SETCNT =100|(% style="width:221px" %)Set the count number to 100.|(% style="width:95px" %)OK 733 733 734 - (% style="color:blue"%)**DownlinkCommand:**664 += 7. Trouble Shooting = 735 735 736 - ***Example**: 0xA6000001~/~/SameasAT+SETCNT=1666 +== 7.1 Why I can't join TTN V3 in US915 / AU915 bands? == 737 737 738 -* **Example**: 0xA6000064 ~/~/ Same as AT+ SETCNT =100 739 739 740 - ===3.3.8SetInterruptMode===669 +It is due to channel mapping. Please see below link: [[Frequency band>>doc:Main.LoRaWAN Communication Debug.WebHome||anchor="H2.NoticeofUS9152FCN4702FAU915Frequencyband"]] 741 741 742 742 743 - Feature,SetInterruptmodeforPA8 of pin.672 +== 7.2 AT Command input doesn't work == 744 744 745 -When AT+INTMOD=0 is set, PA8 is used as a digital input port. 746 746 747 -(% style="color:blue" %)** ATCommand:AT+INTMOD**675 +In the case if user can see the console output but can't type input to the device. Please check if you already include the (% style="color:blue" %)**ENTER**(%%) while sending out the command. Some serial tool doesn't send (% style="color:blue" %)**ENTER**(%%) while press the send key, user need to add ENTER in their string. 748 748 749 -(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %) 750 -|=(% style="width: 155px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 197px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 158px;background-color:#D9E2F3;color:#0070C0" %)**Response** 751 -|(% style="width:154px" %)AT+INTMOD=?|(% style="width:196px" %)Show current interrupt mode|(% style="width:157px" %)((( 752 -0 753 -OK 754 -the mode is 0 =Disable Interrupt 755 -))) 756 -|(% style="width:154px" %)AT+INTMOD=2|(% style="width:196px" %)((( 757 -Set Transmit Interval 758 -0. (Disable Interrupt), 759 -~1. (Trigger by rising and falling edge) 760 -2. (Trigger by falling edge) 761 -3. (Trigger by rising edge) 762 -)))|(% style="width:157px" %)OK 763 763 764 - (%style="color:blue"%)**DownlinkCommand:0x06**678 +== 7.3 Why does the sensor reading show 0 or "No sensor" == 765 765 766 -Format: Command Code (0x06) followed by 3 bytes. 767 767 768 -Th ismeanshatthe interruptmode ofthe end nodeis setto 0x000003=3 (risingedgetrigger),and thetypecodeis06.681 +~1. The measurement object is very close to the sensor, but in the blind spot of the sensor. 769 769 770 - *Example1: Downlink Payload: 06000000~/~/ Turnoffinterruptmode683 +2. Sensor wiring is disconnected 771 771 772 - *Example 2: DownlinkPayload: 06000003 ~/~/ Settheinterruptmodetorising edgetrigger685 +3. Not using the correct decoder 773 773 774 -=== 3.3.9 Set work mode === 775 775 688 +== 7.4 Abnormal readings The gap between multiple readings is too large or the gap between the readings and the actual value is too large == 776 776 777 -Feature: Manually set the work mode 778 778 691 +1) Please check if there is something on the probe affecting its measurement (condensed water, volatile oil, etc.) 779 779 780 - (%style="color:blue"%)**ATCommand: AT+MOD**693 +2) Does it change with temperature, temperature will affect its measurement 781 781 782 -(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:463px" %) 783 -|=(% style="width: 162px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 193px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 108px;background-color:#D9E2F3;color:#0070C0" %)**Response** 784 -|(% style="width:162px" %)AT+MOD=0|(% style="width:191px" %)Set the work mode to 0.|(% style="width:106px" %)OK 785 -|(% style="width:162px" %)AT+MOD=1|(% style="width:191px" %)Set the work mode to 1|(% style="width:106px" %)OK 695 +3) If abnormal data occurs, you can turn on DEBUG mode, Please use downlink or AT COMMAN to enter DEBUG mode. 786 786 787 -(% style="color:blue" %)** DownlinkCommand:**697 +downlink command: (% style="color:blue" %)**F1 01**(%%), AT command: (% style="color:blue" %)**AT+DDEBUG=1** 788 788 789 - ***Example:**0x0A00~/~/Same asAT+MOD=0699 +4) After entering the debug mode, it will send 20 pieces of data at a time, and you can send its uplink to us for analysis 790 790 791 - * **Example:**0x0A01 ~/~/SameasAT+MOD=1701 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDDS75%20-%20LoRaWAN%20Distance%20Detection%20Sensor%20User%20Manual/WebHome/image-20230113135125-2.png?width=1057&height=136&rev=1.1||alt="image-20230113135125-2.png"]] 792 792 793 -= 4. Battery & Power Consumption = 794 794 704 +Its original payload will be longer than other data. Even though it is being parsed, it can be seen that it is abnormal data. 795 795 796 - SW3L-LB use ER26500 + SPC1520 battery pack. Seebelow linkfordetailinformationaboutthe battery infoandhow to replace.706 +Please send the data to us for check. 797 797 798 -[[**Battery Info & Power Consumption Analyze**>>http://wiki.dragino.com/xwiki/bin/view/Main/How%20to%20calculate%20the%20battery%20life%20of%20Dragino%20sensors%3F/]] . 799 799 709 += 8. Order Info = 800 800 801 -= 5. OTA Firmware update = 802 802 712 +Part Number: (% style="color:blue" %)**DDS75-LB-XXX** 803 803 804 -(% class="wikigeneratedid" %) 805 -User can change firmware SW3L-LB to: 714 +(% style="color:red" %)**XXX**(%%): **The default frequency band** 806 806 807 -* Change Frequency band/ region. 808 - 809 -* Update with new features. 810 - 811 -* Fix bugs. 812 - 813 -Firmware and changelog can be downloaded from : **[[Firmware download link>>url:https://www.dropbox.com/sh/kwqv57tp6pejias/AAAopYMATh1GM6fZ-VRCLrpDa?dl=0]]** 814 - 815 -Methods to Update Firmware: 816 - 817 -* (Recommanded way) OTA firmware update via wireless: [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/Firmware%20OTA%20Update%20for%20Sensors/>>url:http://wiki.dragino.com/xwiki/bin/view/Main/Firmware%20OTA%20Update%20for%20Sensors/]] 818 - 819 -* Update through UART TTL interface. **[[Instruction>>url:http://wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H1.LoRaSTv4baseHardware]]**. 820 - 821 -= 6. FAQ = 822 - 823 -== 6.1 AT Commands input doesn't work == 824 - 825 - 826 -In the case if user can see the console output but can't type input to the device. Please check if you already include the (% style="color:green" %)**ENTER**(%%) while sending out the command. Some serial tool doesn't send (% style="color:green" %)**ENTER**(%%) while press the send key, user need to add ENTER in their string. 827 - 828 - 829 -= 7. Order Info = 830 - 831 - 832 -Part Number: (% style="color:blue" %)**SW3L-LB-XXX-YYY** 833 - 834 -(% style="color:red" %)**XXX**(%%): The default frequency band 835 - 836 836 * (% style="color:red" %)**AS923**(%%): LoRaWAN AS923 band 837 837 838 838 * (% style="color:red" %)**AU915**(%%): LoRaWAN AU915 band ... ... @@ -849,43 +849,14 @@ 849 849 850 850 * (% style="color:red" %)**CN470**(%%): LoRaWAN CN470 band 851 851 852 -((( 853 -(% style="color:blue" %)**YYY**(%%): Flow Sensor Model: 854 -))) 855 855 856 -((( 857 - **004:** DW-004 Flow Sensor: diameter: G1/2” / DN15. 450 pulse = 1 L 858 -))) 859 859 860 -((( 861 - **006:** DW-006 Flow Sensor: diameter: G3/4” / DN20. 390 pulse = 1 L 862 -))) 734 += 9. Packing Info = 863 863 864 -((( 865 - **010:** DW-010 Flow Sensor: diameter: G 1” / DN25. 64 pulse = 1 L 866 -))) 867 867 868 -* ((( 869 -calculate flag=0: for SW3L-004 Flow Sensor: 450 pulse = 1 L 870 -))) 871 - 872 -* ((( 873 -calculate flag=1: for SW3L-006 Flow Sensor: 390 pulse = 1 L 874 -))) 875 - 876 -* ((( 877 -calculate flag=2: for SW3L-010 Flow Sensor: 64 pulse = 1 L 878 - 879 - 880 - 881 -))) 882 - 883 -= 8. Packing Info = 884 - 885 - 886 886 (% style="color:#037691" %)**Package Includes**: 887 887 888 -* S W3L-LB LoRaWANFlowSensor739 +* DDS75-LB LoRaWAN Distance Detection Sensor x 1 889 889 890 890 (% style="color:#037691" %)**Dimension and weight**: 891 891 ... ... @@ -897,9 +897,11 @@ 897 897 898 898 * Weight / pcs : g 899 899 900 -= 9. Support = 901 901 902 902 753 += 10. Support = 754 + 755 + 903 903 * Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule. 904 904 905 905 * Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[Support@dragino.cc>>mailto:Support@dragino.cc]].