Last modified by Mengting Qiu on 2023/12/14 11:15

From version 67.20
edited by Xiaoling
on 2023/05/30 15:29
Change comment: There is no comment for this version
To version 67.7
edited by Xiaoling
on 2023/05/30 14:32
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -326,7 +326,7 @@
326 326  
327 327  * (% style="color:#037691" %)**STOP Duration & Alarm Timer**
328 328  
329 -Shows the configure value of [[Alarm for continuously water flow>>||anchor="H3.3.4Alarmforcontinuouslywaterflow"]]
329 +Shows the configure value of [[Alarm for continuously water flow>>||anchor="H3.4Alarmforcontinuouslywaterflow"]]
330 330  
331 331  [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/SW3L%20LoRaWAN%20Outdoor%20Flow%20Sensor/WebHome/image-20220519095747-2.png?width=723&height=113&rev=1.1||alt="image-20220519095747-2.png"]]
332 332  
... ... @@ -339,7 +339,7 @@
339 339  )))
340 340  
341 341  (((
342 -periodically send this uplink every 20 minutes, this interval [[can be changed>>||anchor="H3.3.1SetTransmitIntervalTime"]].
342 +periodically send this uplink every 20 minutes, this interval [[can be changed>>||anchor="H3.1SetTransmitIntervalTime"]].
343 343  )))
344 344  
345 345  (((
... ... @@ -349,9 +349,9 @@
349 349  (% border="1" cellspacing="5" style="background-color:#f2f2f2; width:510px" %)
350 350  |=(% colspan="6" style="width: 510px;background-color:#D9E2F3;color:#0070C0" %)**Water Flow Value,  FPORT=2**
351 351  |(% style="width:60px" %)**Size(bytes)**|(% style="width:130px" %)**1**|(% style="width:130px" %)**4**|(% style="width:30px" %)**1**|(% style="width:50px" %)**1**|(% style="width:80px" %)**4**
352 -|(% style="width:110px" %)**Value**|(% style="width:81px" %)Calculate Flag & [[Alarm>>||anchor="H3.3.4Alarmforcontinuouslywaterflow"]]|(% style="width:95px" %)(((
352 +|(% style="width:110px" %)**Value**|(% style="width:81px" %)Calculate Flag & [[Alarm>>||anchor="H3.4Alarmforcontinuouslywaterflow"]]|(% style="width:95px" %)(((
353 353  Total pulse Or Last Pulse
354 -)))|(% style="width:55px" %)MOD|(% style="width:115px" %)Reserve(0x01)|(% style="width:129px" %)[[Unix TimeStamp>>||anchor="H2.5.2UnixTimeStamp"]]
354 +)))|(% style="width:55px" %)MOD|(% style="width:115px" %)Reserve(0x01)|(% style="width:129px" %)[[Unix TimeStamp>>||anchor="H2.4.1UnixTimeStamp"]]
355 355  
356 356  (% border="1" cellspacing="5" style="background-color:#f2f2f2; width:470px" %)
357 357  |=(% colspan="4" style="width: 470px;background-color:#D9E2F3;color:#0070C0" %)**Status & Alarm field**
... ... @@ -398,7 +398,7 @@
398 398  )))
399 399  
400 400  (((
401 -(% style="color:red" %)**NOTE: User need to set Calculate Flag to proper value before use Flow Sensor. Downlink or AT Command see: **(%%)Refer: [[Set Calculate Flag>>||anchor="H3.3.6Setthecalculateflag"]]
401 +(% style="color:red" %)**NOTE: User need to set Calculate Flag to proper value before use Flow Sensor. Downlink or AT Command see: **(%%)Refer: [[Set Calculate Flag>>||anchor="H3.6Setthecalculateflag"]]
402 402  )))
403 403  
404 404  * (((
... ... @@ -406,7 +406,7 @@
406 406  )))
407 407  
408 408  (((
409 -See [[Alarm for continuously water flow>>||anchor="H3.3.4Alarmforcontinuouslywaterflow"]]
409 +See [[Alarm for continuously water flow>>||anchor="H3.4Alarmforcontinuouslywaterflow"]]
410 410  )))
411 411  
412 412  [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/SW3L%20LoRaWAN%20Outdoor%20Flow%20Sensor/WebHome/image-20220519095946-4.png?width=724&height=65&rev=1.1||alt="image-20220519095946-4.png"]]
... ... @@ -470,7 +470,7 @@
470 470  
471 471  
472 472  (((
473 -SW3L stores sensor values and users can retrieve these history values via the [[downlink command>>||anchor="H2.5DatalogFeature"]].
473 +SW3L stores sensor values and users can retrieve these history values via the [[downlink command>>||anchor="H2.4DatalogFeature"]].
474 474  )))
475 475  
476 476  (((
... ... @@ -486,19 +486,19 @@
486 486  )))
487 487  
488 488  (((
489 -(% style="color:blue" %)**a) DR0:(%%)** max is 11 bytes so one entry of data
489 +**a) DR0:** max is 11 bytes so one entry of data
490 490  )))
491 491  
492 492  (((
493 -(% style="color:blue" %)**b) DR1:(%%)** max is 53 bytes so devices will upload 4 entries of data (total 44 bytes)
493 +**b) DR1:** max is 53 bytes so devices will upload 4 entries of data (total 44 bytes)
494 494  )))
495 495  
496 496  (((
497 -(% style="color:blue" %)**c) DR2:(%%)** total payload includes 11 entries of data
497 +**c) DR2:** total payload includes 11 entries of data
498 498  )))
499 499  
500 500  (((
501 -(% style="color:blue" %)**d) DR3:(%%)** total payload includes 22 entries of data.
501 +**d) DR3:** total payload includes 22 entries of data.
502 502  )))
503 503  
504 504  (((
... ... @@ -513,7 +513,7 @@
513 513  0x31 62 46 B1 F0 62 46 B3 94 07
514 514  )))
515 515  
516 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/SW3L%20LoRaWAN%20Outdoor%20Flow%20Sensor/WebHome/1652926690850-712.png?width=726&height=115&rev=1.1||alt="1652926690850-712.png"]]
516 +[[image:1652926690850-712.png||_mstalt="295178" height="115" width="726"]]
517 517  
518 518  
519 519  (((
... ... @@ -557,7 +557,7 @@
557 557  [FALSE,0,0,287,0.6,2022-04-01 08:10:38],
558 558  )))
559 559  
560 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/SW3L%20LoRaWAN%20Outdoor%20Flow%20Sensor/WebHome/1652926777796-267.png?width=724&height=279&rev=1.1||alt="1652926777796-267.png"]]
560 +[[image:1652926777796-267.png||_mstalt="300183" height="279" width="724"]]
561 561  
562 562  
563 563  == 2.4 Payload Decoder file ==
... ... @@ -645,7 +645,7 @@
645 645  )))
646 646  
647 647  
648 -== 2.6 Frequency Plans ==
648 +== 2.7 Frequency Plans ==
649 649  
650 650  
651 651  The CPL03-LB uses OTAA mode and below frequency plans by default. If user want to use it with different frequency plan, please refer the AT command sets.
... ... @@ -661,12 +661,9 @@
661 661  CPL03-LB supports below configure method:
662 662  
663 663  * AT Command via Bluetooth Connection (**Recommended**): [[BLE Configure Instruction>>http://wiki.dragino.com/xwiki/bin/view/Main/BLE%20Bluetooth%20Remote%20Configure/]].
664 -
665 665  * AT Command via UART Connection : See [[UART Connection>>http://wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H2.3UARTConnectionforSN50v3basemotherboard]].
666 -
667 667  * LoRaWAN Downlink.  Instruction for different platforms: See [[IoT LoRaWAN Server>>http://wiki.dragino.com/xwiki/bin/view/Main/]] section.
668 668  
669 -
670 670  == 3.2 General Commands ==
671 671  
672 672  
... ... @@ -673,7 +673,6 @@
673 673  These commands are to configure:
674 674  
675 675  * General system settings like: uplink interval.
676 -
677 677  * LoRaWAN protocol & radio related command.
678 678  
679 679  They are same for all Dragino Devices which support DLWS-005 LoRaWAN Stack. These commands can be found on the wiki:
... ... @@ -726,12 +726,12 @@
726 726  Example 1: Downlink Payload: 0100001E  ~/~/ Set Transmit Interval (TDC) = 30 seconds
727 727  )))
728 728  * (((
729 -Example 2: Downlink Payload: 0100003C  ~/~/ Set Transmit Interval (TDC) = 60 seconds
730 -)))
725 +Example 2: Downlink Payload: 0100003C  ~/~/ Set Transmit Interval (TDC) = 60 seconds
731 731  
732 732  
728 +
729 +)))
733 733  
734 -
735 735  === 3.3.2 Quit AT Command ===
736 736  
737 737  
... ... @@ -758,85 +758,113 @@
758 758  Sensor will upload Device Status via FPORT=5. See payload section for detail.
759 759  
760 760  
761 -=== 3.3.4 Alarm for continuously water flow ===
757 +=== 3.3.4 Enable / Disable Alarm ===
762 762  
763 763  
760 +Feature: Enable/Disable Alarm for open/close event. Default value 0.
761 +
762 +(% style="color:blue" %)**AT Command:**
763 +
764 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:520px" %)
765 +|(% style="background-color:#d9e2f3; color:#0070c0; width:154px" %)**Command Example**|(% style="background-color:#d9e2f3; color:#0070c0; width:278px" %)**Function**|(% style="background-color:#d9e2f3; color:#0070c0; width:88px" %)**Response**
766 +|(% style="width:154px" %)AT+DISALARM=1|(% style="width:278px" %)End node will only send packets in TDC time.|OK
767 +|(% style="width:154px" %)AT+DISALARM=0|(% style="width:278px" %)End node will send packets in TDC time or status change for door sensor|OK
768 +
769 +(% style="color:blue" %)**Downlink Command:**
770 +
771 +**0xA7 01**  ~/~/  Same As AT+DISALARM=1
772 +
773 +**0xA7 00    ** ~/~/  Same As AT+DISALARM=0
774 +
775 +
776 +=== 3.3.5 Alarm Base on Timeout ===
777 +
778 +
764 764  (((
765 -This feature is to monitor and send Alarm for continuously water flow.
780 +CPL03-LB can monitor the timeout for a status change, this feature can be used to monitor some events such as door opening too long etc. Related Parameters are:
766 766  )))
767 767  
783 +
768 768  (((
769 -Example case is for Toilet water monitoring, if some one push toilet button, the toilet will have water flow. If the toilet button has broken and can't returned to original state, the water flow will keep for hours or days which cause huge waste for water.
785 +(% style="color:#4f81bd" %)**1. Keep Status: Status to be monitor**
770 770  )))
771 771  
772 772  (((
773 -To monitor this faulty and send alarm, there are two settings:
789 +**Keep Status = 1**: Monitor Close to Open event
774 774  )))
775 775  
776 -* (((
777 -(% style="color:#4f81bd" %)**Stop Duration: Unit: Second**
792 +(((
793 +**Keep Status = 0**: Monitor Open to Close event
778 778  )))
779 779  
796 +
780 780  (((
781 -Default: 15s, If SW3L didn't see any water flow in 15s, SW3L will consider stop of water flow event.
798 +(% style="color:#4f81bd" %)**2. Keep Time: Timeout to send an Alarm**
782 782  )))
783 783  
784 -* (((
785 -(% style="color:#4f81bd" %)**Alarm Timer: Units: Minute; Default 0 minutes (means Alarm disable)**
801 +(((
802 +Range 0 ~~ 65535(0xFFFF) seconds.
786 786  )))
787 787  
788 788  (((
789 -**Example:** 3 minutes, if SW3L detect a start of water flow event and didn't detect a stop event within Alarm timer, SW3L will send an Alarm to indicate a water flow abnormal alarm.
806 +If** keep time = 0**, Disable Alarm Base on Timeout feature.
790 790  )))
791 791  
792 792  (((
793 -So for example, If we set stop duration=15s and Alarm Timer=3minutes. If the toilet water flow continuously for more than 3 minutes, Sensor will send an alarm (in Confirmed MODE) to platform.
810 +If **keep time > 0**, device will monitor the keep status event and send an alarm when status doesn’t change after timeout.
794 794  )))
795 795  
813 +
796 796  (((
797 -(% style="color:red" %)**Note:** **After this alarm is send, sensor will consider a stop of water flow and count for another new event. So if water flow waste last for 1 hour, Sensor will keep sending alarm every 3 minutes.**
815 +(% style="color:#4f81bd" %)**AT Command**(%%) to configure:
798 798  )))
799 799  
800 800  (((
801 -(% style="color:#4f81bd" %)**AT Command**(%%) to configure:
819 +(% style="color:blue" %)**AT+TTRIG=1,30**(%%)  ~-~-> When the **Keep Status** change from connect to disconnect, and device remains in disconnect status for more than 30 seconds. CPL03-LB will send an uplink packet, the [[Alarm bit>>||anchor="H2.3.3Real-TimeOpen2FCloseStatus2CUplinkFPORT3D2"]] (the second bit of 1^^st^^ byte of payload) on this uplink packet is set to 1.
802 802  )))
803 803  
804 -* (((
805 -AT+PTRIG=15, ~-~-> Set Stop duration: 15s, Alarm Timer: 3 minutes.
822 +(((
823 +(% style="color:blue" %)**AT+TTIG=0,0 **(%%) ~-~-> Default Value, disable timeout Alarm.
806 806  )))
807 807  
808 -* (((
809 -AT+ PTRIG=15,0  ~-~-> Default Value, disable water waste Alarm.
826 +
827 +(((
828 +(% style="color:#4f81bd" %)**Downlink Command**(%%) to configure:
810 810  )))
811 811  
812 812  (((
813 -(% style="color:#4f81bd" %)**Downlink Command**(%%) to configure: 
832 +**Command: 0xA9 aa bb cc**
814 814  )))
815 815  
816 816  (((
817 -Command: **0xAA aa bb cc**
836 +**A9: **Command Type Code
818 818  )))
819 819  
820 820  (((
821 -AA: Command Type Code
840 +**aa: **status to be monitored
822 822  )))
823 823  
824 824  (((
825 -aa: Stop duration
844 +**bb cc: **timeout.
826 826  )))
827 827  
847 +
828 828  (((
829 -bb cc: Alarm Timer
849 +If user send 0xA9 01 00 1E: equal to AT+TTRIG=1,30
830 830  )))
831 831  
832 832  (((
833 -If user send 0xAA 0F 00 03: equal to AT+PTRIG=15,3
853 +Or
834 834  )))
835 835  
856 +(((
857 +0xA9 00 00 00: Equal to AT+TTRIG=0,0. Disable timeout Alarm.
858 +)))
836 836  
837 -=== 3.3.5 Clear Flash Record ===
838 838  
861 +=== 3.3.6 Clear Flash Record ===
839 839  
863 +
840 840  Feature: Clear flash storage for data log feature.
841 841  
842 842  (% style="color:blue" %)**AT Command: AT+CLRDTA**
... ... @@ -855,9 +855,35 @@
855 855  
856 856  
857 857  
858 -=== 3.3.6 Set the calculate flag ===
882 +=== 3.3.7 Set trigger mode ===
859 859  
860 860  
885 +Feature: Set the trigger interrupt mode.
886 +
887 +(% style="color:blue" %)**AT Command: AT+TTRMOD**
888 +
889 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:495px" %)
890 +|=(% style="width: 157px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 246px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 92px;background-color:#D9E2F3;color:#0070C0" %)**Response**
891 +|(% style="width:157px" %)(((
892 +AT+TTRMOD=1
893 +)))|(% style="width:156px" %)Count and trigger from open to close (rising edge)|(% style="width:89px" %)(((
894 +(((
895 +OK
896 +)))
897 +)))
898 +|(% style="width:157px" %)(((
899 +AT+TTRMOD=0
900 +)))|(% style="width:156px" %)Count and trigger from close to open (falling edge)|(% style="width:89px" %)(((
901 +OK
902 +)))
903 +
904 +(% style="color:blue" %)**Downlink Command:**
905 +
906 +* **Example**: 0xA401  ~/~/  Same as AT+ TTRMOD =1
907 +
908 +=== 3.3.8 Set the calculate flag ===
909 +
910 +
861 861  Feature: Set the calculate flag
862 862  
863 863  (% style="color:blue" %)**AT Command: AT+CALCFLAG**
... ... @@ -871,10 +871,9 @@
871 871  
872 872  * **Example**: 0XA501  ~/~/  Same as AT+CALCFLAG =1
873 873  
924 +=== 3.3.9 Set count number ===
874 874  
875 -=== 3.3.7 Set count number ===
876 876  
877 -
878 878  Feature: Manually set the count number
879 879  
880 880  (% style="color:blue" %)**AT Command: AT+SETCNT**
... ... @@ -890,14 +890,9 @@
890 890  
891 891  * **Example**: 0xA6000064  ~/~/  Same as AT+ SETCNT =100
892 892  
942 +=== 3.3.10 Set Interrupt Mode ===
893 893  
894 894  
895 -
896 -
897 -
898 -=== 3.3.8 Set Interrupt Mode ===
899 -
900 -
901 901  Feature, Set Interrupt mode for PA8 of pin.
902 902  
903 903  When AT+INTMOD=0 is set, PA8 is used as a digital input port.
... ... @@ -929,28 +929,35 @@
929 929  
930 930  * Example 2: Downlink Payload: 06000003  ~/~/  Set the interrupt mode to rising edge trigger
931 931  
976 +=== 3.3.11 Set Power Output Duration ===
932 932  
933 933  
979 +Control the output duration 5V . Before each sampling, device will
934 934  
935 -=== 3.3.9 Set work mode ===
981 +~1. first enable the power output to external sensor,
936 936  
983 +2. keep it on as per duration, read sensor value and construct uplink payload
937 937  
938 -Feature: Manually set the work mode
985 +3. final, close the power output.
939 939  
987 +(% style="color:blue" %)**AT Command: AT+5VT**
940 940  
941 -(% style="color:blue" %)**AT Command: AT+MOD**
989 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %)
990 +|=(% style="width: 155px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 197px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 158px;background-color:#D9E2F3;color:#0070C0" %)**Response**
991 +|(% style="width:154px" %)AT+5VT=?|(% style="width:196px" %)Show 5V open time.|(% style="width:157px" %)0 (default)
992 +OK
993 +|(% style="width:154px" %)AT+5VT=500|(% style="width:196px" %)Close after a delay of 1000 milliseconds.|(% style="width:157px" %)OK
942 942  
943 -(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:463px" %)
944 -|=(% style="width: 162px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 193px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 108px;background-color:#D9E2F3;color:#0070C0" %)**Response**
945 -|(% style="width:162px" %)AT+MOD=0|(% style="width:191px" %)Set the work mode to 0.|(% style="width:106px" %)OK
946 -|(% style="width:162px" %)AT+MOD=1|(% style="width:191px" %)Set the work mode to 1|(% style="width:106px" %)OK
995 +(% style="color:blue" %)**Downlink Command: 0x07**
947 947  
948 -(% style="color:blue" %)**Downlink Command:**
997 +Format: Command Code (0x07) followed by 2 bytes.
949 949  
950 -* **Example: **0x0A00  ~/~/  Same as AT+MOD=0
999 +The first and second bytes are the time to turn on.
951 951  
952 -* **Example:** 0x0A01  ~/~/  Same as AT+MOD=1
1001 +* Example 1: Downlink Payload: 070000  **~-~-->**  AT+5VT=0
953 953  
1003 +* Example 2: Downlink Payload: 0701F4  **~-~-->**  AT+5VT=500
1004 +
954 954  = 4. Battery & Power Consumption =
955 955  
956 956  
... ... @@ -990,7 +990,7 @@
990 990  = 7. Order Info =
991 991  
992 992  
993 -Part Number: (% style="color:blue" %)**SW3L-LB-XXX-YYY**
1044 +Part Number: (% style="color:blue" %)**CPL03-LB-XXX**
994 994  
995 995  (% style="color:red" %)**XXX**(%%): The default frequency band
996 996  
... ... @@ -1010,41 +1010,12 @@
1010 1010  
1011 1011  * (% style="color:red" %)**CN470**(%%): LoRaWAN CN470 band
1012 1012  
1013 -(((
1014 -(% style="color:blue" %)**YYY**(%%): Flow Sensor Model:
1015 -)))
1016 -
1017 -(((
1018 - **004:** DW-004 Flow Sensor: diameter: G1/2” / DN15.  450 pulse = 1 L
1019 -)))
1020 -
1021 -(((
1022 - **006:** DW-006 Flow Sensor: diameter: G3/4” / DN20. 390 pulse = 1 L
1023 -)))
1024 -
1025 -(((
1026 - **010:** DW-010 Flow Sensor: diameter: G 1” / DN25. 64 pulse = 1 L
1027 -)))
1028 -
1029 -* (((
1030 -calculate flag=0: for SW3L-004 Flow Sensor: 450 pulse = 1 L
1031 -)))
1032 -
1033 -* (((
1034 -calculate flag=1: for SW3L-006 Flow Sensor: 390 pulse = 1 L
1035 -)))
1036 -
1037 -* (((
1038 -calculate flag=2: for SW3L-010 Flow Sensor: 64  pulse = 1 L
1039 -)))
1040 -
1041 -
1042 1042  = 8. ​Packing Info =
1043 1043  
1044 1044  
1045 1045  (% style="color:#037691" %)**Package Includes**:
1046 1046  
1047 -* SW3L-LB LoRaWAN Flow Sensor
1069 +* CPL03-LB LoRaWAN Pulse/Contact Sensor
1048 1048  
1049 1049  (% style="color:#037691" %)**Dimension and weight**:
1050 1050  
... ... @@ -1056,8 +1056,6 @@
1056 1056  
1057 1057  * Weight / pcs : g
1058 1058  
1059 -
1060 -
1061 1061  = 9. Support =