Changes for page DS20L -- LoRaWAN Smart Distance Detector User Manual 01
Last modified by Mengting Qiu on 2023/12/14 11:15
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -326,7 +326,7 @@ 326 326 327 327 * (% style="color:#037691" %)**STOP Duration & Alarm Timer** 328 328 329 -Shows the configure value of [[Alarm for continuously water flow>>||anchor="H3.4Alarmforcontinuouslywaterflow"]] 329 +Shows the configure value of [[Alarm for continuously water flow>>||anchor="H3.3.4Alarmforcontinuouslywaterflow"]] 330 330 331 331 [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/SW3L%20LoRaWAN%20Outdoor%20Flow%20Sensor/WebHome/image-20220519095747-2.png?width=723&height=113&rev=1.1||alt="image-20220519095747-2.png"]] 332 332 ... ... @@ -339,7 +339,7 @@ 339 339 ))) 340 340 341 341 ((( 342 -periodically send this uplink every 20 minutes, this interval [[can be changed>>||anchor="H3.1SetTransmitIntervalTime"]]. 342 +periodically send this uplink every 20 minutes, this interval [[can be changed>>||anchor="H3.3.1SetTransmitIntervalTime"]]. 343 343 ))) 344 344 345 345 ((( ... ... @@ -349,9 +349,9 @@ 349 349 (% border="1" cellspacing="5" style="background-color:#f2f2f2; width:510px" %) 350 350 |=(% colspan="6" style="width: 510px;background-color:#D9E2F3;color:#0070C0" %)**Water Flow Value, FPORT=2** 351 351 |(% style="width:60px" %)**Size(bytes)**|(% style="width:130px" %)**1**|(% style="width:130px" %)**4**|(% style="width:30px" %)**1**|(% style="width:50px" %)**1**|(% style="width:80px" %)**4** 352 -|(% style="width:110px" %)**Value**|(% style="width:81px" %)Calculate Flag & [[Alarm>>||anchor="H3.4Alarmforcontinuouslywaterflow"]]|(% style="width:95px" %)((( 352 +|(% style="width:110px" %)**Value**|(% style="width:81px" %)Calculate Flag & [[Alarm>>||anchor="H3.3.4Alarmforcontinuouslywaterflow"]]|(% style="width:95px" %)((( 353 353 Total pulse Or Last Pulse 354 -)))|(% style="width:55px" %)MOD|(% style="width:115px" %)Reserve(0x01)|(% style="width:129px" %)[[Unix TimeStamp>>||anchor="H2. 4.1UnixTimeStamp"]]354 +)))|(% style="width:55px" %)MOD|(% style="width:115px" %)Reserve(0x01)|(% style="width:129px" %)[[Unix TimeStamp>>||anchor="H2.5.2UnixTimeStamp"]] 355 355 356 356 (% border="1" cellspacing="5" style="background-color:#f2f2f2; width:470px" %) 357 357 |=(% colspan="4" style="width: 470px;background-color:#D9E2F3;color:#0070C0" %)**Status & Alarm field** ... ... @@ -398,7 +398,7 @@ 398 398 ))) 399 399 400 400 ((( 401 -(% style="color:red" %)**NOTE: User need to set Calculate Flag to proper value before use Flow Sensor. Downlink or AT Command see: **(%%)Refer: [[Set Calculate Flag>>||anchor="H3.6Setthecalculateflag"]] 401 +(% style="color:red" %)**NOTE: User need to set Calculate Flag to proper value before use Flow Sensor. Downlink or AT Command see: **(%%)Refer: [[Set Calculate Flag>>||anchor="H3.3.6Setthecalculateflag"]] 402 402 ))) 403 403 404 404 * ((( ... ... @@ -406,7 +406,7 @@ 406 406 ))) 407 407 408 408 ((( 409 -See [[Alarm for continuously water flow>>||anchor="H3.4Alarmforcontinuouslywaterflow"]] 409 +See [[Alarm for continuously water flow>>||anchor="H3.3.4Alarmforcontinuouslywaterflow"]] 410 410 ))) 411 411 412 412 [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/SW3L%20LoRaWAN%20Outdoor%20Flow%20Sensor/WebHome/image-20220519095946-4.png?width=724&height=65&rev=1.1||alt="image-20220519095946-4.png"]] ... ... @@ -470,7 +470,7 @@ 470 470 471 471 472 472 ((( 473 -SW3L stores sensor values and users can retrieve these history values via the [[downlink command>>||anchor="H2. 4DatalogFeature"]].473 +SW3L stores sensor values and users can retrieve these history values via the [[downlink command>>||anchor="H2.5DatalogFeature"]]. 474 474 ))) 475 475 476 476 ((( ... ... @@ -645,7 +645,7 @@ 645 645 ))) 646 646 647 647 648 -== 2. 7Frequency Plans ==648 +== 2.6 Frequency Plans == 649 649 650 650 651 651 The CPL03-LB uses OTAA mode and below frequency plans by default. If user want to use it with different frequency plan, please refer the AT command sets. ... ... @@ -661,9 +661,12 @@ 661 661 CPL03-LB supports below configure method: 662 662 663 663 * AT Command via Bluetooth Connection (**Recommended**): [[BLE Configure Instruction>>http://wiki.dragino.com/xwiki/bin/view/Main/BLE%20Bluetooth%20Remote%20Configure/]]. 664 + 664 664 * AT Command via UART Connection : See [[UART Connection>>http://wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H2.3UARTConnectionforSN50v3basemotherboard]]. 666 + 665 665 * LoRaWAN Downlink. Instruction for different platforms: See [[IoT LoRaWAN Server>>http://wiki.dragino.com/xwiki/bin/view/Main/]] section. 666 666 669 + 667 667 == 3.2 General Commands == 668 668 669 669 ... ... @@ -670,6 +670,7 @@ 670 670 These commands are to configure: 671 671 672 672 * General system settings like: uplink interval. 676 + 673 673 * LoRaWAN protocol & radio related command. 674 674 675 675 They are same for all Dragino Devices which support DLWS-005 LoRaWAN Stack. These commands can be found on the wiki: ... ... @@ -754,7 +754,7 @@ 754 754 Sensor will upload Device Status via FPORT=5. See payload section for detail. 755 755 756 756 757 -== 3.3.4 Alarm for continuously water flow == 761 +=== 3.3.4 Alarm for continuously water flow === 758 758 759 759 760 760 (((