Changes for page DS20L -- LoRaWAN Smart Distance Detector User Manual 01
Last modified by Mengting Qiu on 2023/12/14 11:15
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -326,7 +326,7 @@ 326 326 327 327 * (% style="color:#037691" %)**STOP Duration & Alarm Timer** 328 328 329 -Shows the configure value of [[Alarm for continuously water flow>>||anchor="H3.4Alarmforcontinuouslywaterflow"]] 329 +Shows the configure value of [[Alarm for continuously water flow>>||anchor="H3.3.4Alarmforcontinuouslywaterflow"]] 330 330 331 331 [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/SW3L%20LoRaWAN%20Outdoor%20Flow%20Sensor/WebHome/image-20220519095747-2.png?width=723&height=113&rev=1.1||alt="image-20220519095747-2.png"]] 332 332 ... ... @@ -339,7 +339,7 @@ 339 339 ))) 340 340 341 341 ((( 342 -periodically send this uplink every 20 minutes, this interval [[can be changed>>||anchor="H3.1SetTransmitIntervalTime"]]. 342 +periodically send this uplink every 20 minutes, this interval [[can be changed>>||anchor="H3.3.1SetTransmitIntervalTime"]]. 343 343 ))) 344 344 345 345 ((( ... ... @@ -351,7 +351,7 @@ 351 351 |(% style="width:60px" %)**Size(bytes)**|(% style="width:130px" %)**1**|(% style="width:130px" %)**4**|(% style="width:30px" %)**1**|(% style="width:50px" %)**1**|(% style="width:80px" %)**4** 352 352 |(% style="width:110px" %)**Value**|(% style="width:81px" %)Calculate Flag & [[Alarm>>||anchor="H3.4Alarmforcontinuouslywaterflow"]]|(% style="width:95px" %)((( 353 353 Total pulse Or Last Pulse 354 -)))|(% style="width:55px" %)MOD|(% style="width:115px" %)Reserve(0x01)|(% style="width:129px" %)[[Unix TimeStamp>>||anchor="H2. 4.1UnixTimeStamp"]]354 +)))|(% style="width:55px" %)MOD|(% style="width:115px" %)Reserve(0x01)|(% style="width:129px" %)[[Unix TimeStamp>>||anchor="H2.5.2UnixTimeStamp"]] 355 355 356 356 (% border="1" cellspacing="5" style="background-color:#f2f2f2; width:470px" %) 357 357 |=(% colspan="4" style="width: 470px;background-color:#D9E2F3;color:#0070C0" %)**Status & Alarm field** ... ... @@ -754,7 +754,7 @@ 754 754 Sensor will upload Device Status via FPORT=5. See payload section for detail. 755 755 756 756 757 -== 3.3.4 Alarm for continuously water flow == 757 +=== 3.3.4 Alarm for continuously water flow === 758 758 759 759 760 760 ((( ... ... @@ -1007,19 +1007,19 @@ 1007 1007 * (% style="color:red" %)**CN470**(%%): LoRaWAN CN470 band 1008 1008 1009 1009 ((( 1010 -(% style="color: #4f81bd" %)**YYY**(%%): Flow Sensor Model:1010 +(% style="color:blue" %)**YYY**(%%): Flow Sensor Model: 1011 1011 ))) 1012 1012 1013 1013 ((( 1014 - 004: DW-004 Flow Sensor: diameter: G1/2” / DN15. 450 pulse = 1 L 1014 + **004:** DW-004 Flow Sensor: diameter: G1/2” / DN15. 450 pulse = 1 L 1015 1015 ))) 1016 1016 1017 1017 ((( 1018 - 006: DW-006 Flow Sensor: diameter: G3/4” / DN20. 390 pulse = 1 L 1018 + **006:** DW-006 Flow Sensor: diameter: G3/4” / DN20. 390 pulse = 1 L 1019 1019 ))) 1020 1020 1021 1021 ((( 1022 - 010: DW-010 Flow Sensor: diameter: G 1” / DN25. 64 pulse = 1 L 1022 + **010:** DW-010 Flow Sensor: diameter: G 1” / DN25. 64 pulse = 1 L 1023 1023 ))) 1024 1024 1025 1025 * (((