Changes for page DS20L -- LoRaWAN Smart Distance Detector User Manual 01
Last modified by Mengting Qiu on 2023/12/14 11:15
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 1 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,7 +1,10 @@ 1 1 (% style="text-align:center" %) 2 -[[image:image-20230530 084608-2.jpeg||height="707" width="707"]]2 +[[image:image-20230530140053-1.jpeg||height="645" width="645"]] 3 3 4 4 5 + 6 + 7 + 5 5 **Table of Contents:** 6 6 7 7 {{toc/}} ... ... @@ -13,26 +13,24 @@ 13 13 14 14 = 1. Introduction = 15 15 16 -== 1.1 What is CPL03-LB LoRaWANPulse/ContactSensor ==19 +== 1.1 What is SW3L-LB LoRaWAN Flow Sensor == 17 17 18 18 19 -The Dragino CPL03-LB is a (% style="color:blue" %)**LoRaWANContactSensor**(%%)for Internet of Things solution. It detectsdry contactstatus, opentime,opencounts,andthenuploadto IoT server via LoRaWAN wirelessprotocol.22 +The Dragino SW3L-LB is a (% style="color:blue" %)**LoRaWAN Flow Sensor**(%%). It detects water flow volume and uplink to IoT server via LoRaWAN network. User can use this to(% style="color:blue" %)** monitor the water usage for buildings.** 20 20 21 -The CPL03-LB will sendperiodically dataeveryday as well asforeachdrycontactaction. It also countsthecontact opentimescalculatelast openuration.User can alsodisabletheuplinkforeach open/closeevent, instead, devicecan count each openeventand uplink periodically.24 +The SW3L-LB will send water flow volume every 20 minutes. It can also (% style="color:blue" %)**detect the water flow status**(%%) and (% style="color:blue" %)**send Alarm**(%%), to avoid the waste for water usage such as broken toilet case. 22 22 23 - TheLoRawirelesstechnology usedinCPL03-LBallowsdeviceto senddata andreachxtremely longrangesat lowdata-rates.It providesultra-longrangespreadspectrumcommunicationandhighinterference immunity whilst minimizing current consumption.26 +SW3L-LB is designed for both indoor and outdoor use. It has a weatherproof enclosure and industrial level battery to work in low to high temperatures. 24 24 25 - CPL03-LB(%style="color:blue"%)**supportsopen alarmfeature**(%%), usercanset open alarmforinstantnotice.CPL03-LB (% style="color:blue"%)**supportsDatalogfeature**(%%),it cansavethedatawhenthere isno LoRaWAN networkand uplinkwhennetworkrecover.28 +The LoRa wireless technology used in SW3L-LB allows device to send data and reach extremely long ranges at low data-rates. It provides ultra-long range spread spectrum communication and high interference immunity whilst minimizing current consumption. 26 26 27 - CPL03-LBisdesigned foroutdoorse.It hasa weatherproofenclosureindustriallevelatterytoworkinlowtohightemperatures.30 +SW3L-LB (% style="color:blue" %)**supports BLE configure**(%%) and (% style="color:blue" %)**wireless OTA update**(%%) which make user easy to use. 28 28 29 - CPL03-LB(%style="color:blue"%)**supports BLE configure**(%%) and (% style="color:blue" %)**wirelessOTAupdate**(%%)whichmakeuser easytouse.32 +SW3L-LB is powered by (% style="color:blue" %)**8500mAh Li-SOCI2 battery**(%%), it is designed for long term use up to 5 years. 30 30 31 - CPL03-LB is poweredby (%style="color:blue"%)**8500mAhLi-SOCI2battery**(%%), itisdesignedforlongtermuseupto5years.34 +Each SW3L-LB is pre-load with a set of unique keys for LoRaWAN registrations, register these keys to local LoRaWAN server and it will auto connect after power on. 32 32 33 -Each CPL03-LB is pre-load with a set of unique keys for LoRaWAN registrations, register these keys to local LoRaWAN server and it will auto connect after power on. 34 34 35 - 36 36 [[image:image-20230530135919-1.png||height="404" width="806"]] 37 37 38 38 ... ... @@ -42,10 +42,9 @@ 42 42 * LoRaWAN 1.0.3 Class A 43 43 * Bands: CN470/EU433/KR920/US915/EU868/AS923/AU915/IN865 44 44 * Ultra-low power consumption 45 -* Open/Close detect 46 -* Open/Close statistics 47 -* Temperature & Humidity alarm 48 -* supports open alarm feature 46 +* Upload water flow volume 47 +* Monitor water waste 48 +* AT Commands to change parameters 49 49 * supports Datalog feature 50 50 * Support Bluetooth v5.1 and LoRaWAN remote configure 51 51 * Support wireless OTA update firmware ... ... @@ -53,7 +53,6 @@ 53 53 * Downlink to change configure 54 54 * 8500mAh Battery for long term use 55 55 56 - 57 57 == 1.3 Specification == 58 58 59 59 ... ... @@ -82,15 +82,14 @@ 82 82 * Sleep Mode: 5uA @ 3.3v 83 83 * LoRa Transmit Mode: 125mA @ 20dBm, 82mA @ 14dBm 84 84 85 - 86 86 == 1.4 Applications == 87 87 88 88 89 -* Open/Close Detection 90 -* Pulse meter application 91 -* Dry Contact Detection 87 +* Flow Sensor application 88 +* Water Control 89 +* Toilet Flow Sensor 90 +* Monitor Waste water 92 92 93 - 94 94 == 1.5 Sleep mode and working mode == 95 95 96 96 ... ... @@ -118,11 +118,10 @@ 118 118 ))) 119 119 |(% style="width:167px" %)Fast press ACT 5 times.|(% style="width:117px" %)Deactivate Device|(% style="width:225px" %)(% style="color:red" %)**Red led**(%%) will solid on for 5 seconds. Means device is in Deep Sleep Mode. 120 120 121 - 122 122 == 1.7 BLE connection == 123 123 124 124 125 - CPL03-LB support BLE remote configure.122 +SW3L-LB support BLE remote configure. 126 126 127 127 128 128 BLE can be used to configure the parameter of sensor or see the console output from sensor. BLE will be only activate on below case: ... ... @@ -139,9 +139,21 @@ 139 139 [[image:image-20230523174230-1.png]] 140 140 141 141 142 -== 1.9 Mechanical==139 +== 1.9 Flow Sensor Spec == 143 143 144 144 142 +((( 143 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:510px" %) 144 +|=(% style="width: 80px;background-color:#D9E2F3;color:#0070C0" %)**Model**|=(% style="width: 80px;background-color:#D9E2F3;color:#0070C0" %)**Probe**|=(% style="width: 80px;background-color:#D9E2F3;color:#0070C0" %)**Diameter**|=(% style="width: 80px;background-color:#D9E2F3;color:#0070C0" %)**Range**|=(% style="width: 80px;background-color:#D9E2F3;color:#0070C0" %)**Max Pressure**|=(% style="width: 110px;background-color:#D9E2F3;color:#0070C0" %)**Measure** 145 +|(% style="width:88px" %)SW3L-004|(% style="width:75px" %)DW-004|(% style="width:107px" %)G1/2" /DN15|(% style="width:101px" %)1~~30L/min|(% style="width:116px" %)≤ 2.0Mpa|(% style="width:124px" %)450 pulse = 1 L 146 +|(% style="width:88px" %)SW3L-006|(% style="width:75px" %)DW-006|(% style="width:107px" %)G3/4" /DN20|(% style="width:101px" %)1~~60L/min|(% style="width:116px" %)≤ 1.2Mpa|(% style="width:124px" %)390 pulse = 1 L 147 +|(% style="width:88px" %)SW3L-010|(% style="width:75px" %)DW-010|(% style="width:107px" %)G 1" /DN25|(% style="width:101px" %)2~~100L/min|(% style="width:116px" %)≤ 2.0Mpa|(% style="width:124px" %)64 pulse = 1 L 148 +))) 149 + 150 + 151 +== 2.10 Mechanical == 152 + 153 + 145 145 [[image:Main.User Manual for LoRaWAN End Nodes.D20-LBD22-LBD23-LB_LoRaWAN_Temperature_Sensor_User_Manual.WebHome@1675143884058-338.png]] 146 146 147 147 ... ... @@ -151,12 +151,27 @@ 151 151 [[image:Main.User Manual for LoRaWAN End Nodes.D20-LBD22-LBD23-LB_LoRaWAN_Temperature_Sensor_User_Manual.WebHome@1675143909447-639.png]] 152 152 153 153 163 +(% style="color:blue" %)**DW-004 Flow Sensor: diameter: G1/2” / DN15. 450 pulse = 1 L** 164 + 165 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/SW3L%20LoRaWAN%20Outdoor%20Flow%20Sensor/WebHome/image-20220519091350-1.png?width=722&height=385&rev=1.1||alt="image-20220519091350-1.png"]] 166 + 167 + 168 +(% style="color:blue" %)**006: DW-006 Flow Sensor: diameter: G3/4” / DN20. 390 pulse = 1 L** 169 + 170 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/SW3L%20LoRaWAN%20Outdoor%20Flow%20Sensor/WebHome/image-20220519091423-2.png?width=723&height=258&rev=1.1||alt="image-20220519091423-2.png"]] 171 + 172 + 173 +(% style="color:blue" %)**010: DW-010 Flow Sensor: diameter: G 1” / DN25. 64 pulse = 1 L** 174 + 175 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/SW3L%20LoRaWAN%20Outdoor%20Flow%20Sensor/WebHome/image-20220519091423-3.png?width=724&height=448&rev=1.1||alt="image-20220519091423-3.png"]] 176 + 177 + 154 154 = 2. Configure CPL03-LB to connect to LoRaWAN network = 155 155 156 156 == 2.1 How it works == 157 157 158 158 159 -The CPL03-LB is configured as (% style="color:#037691" %)**LoRaWAN OTAA Class A**(%%) mode by default. It has OTAA keys to join LoRaWAN network. To connect a local LoRaWAN network, you need to input the OTAA keys in the LoRaWAN IoT server and press the button to activate theCPL03-LB. It will automatically join the network via OTAA and start to send the sensor value. The default uplink interval is 20 minutes.183 +The SW3L-LB is configured as (% style="color:#037691" %)**LoRaWAN OTAA Class A**(%%) mode by default. It has OTAA keys to join LoRaWAN network. To connect a local LoRaWAN network, you need to input the OTAA keys in the LoRaWAN IoT server and press the button to activate the SW3L-LB. It will automatically join the network via OTAA and start to send the sensor value. The default uplink interval is 20 minutes. 160 160 161 161 (% style="display:none" %) (%%) 162 162 ... ... @@ -170,9 +170,9 @@ 170 170 [[image:image-20230530135929-2.png||height="404" width="806"]](% style="display:none" %) 171 171 172 172 173 -(% style="color:blue" %)**Step 1:**(%%) Create a device in TTN with the OTAA keys from CPL03-LB.197 +(% style="color:blue" %)**Step 1:**(%%) Create a device in TTN with the OTAA keys from SW3L-LB. 174 174 175 -Each CPL03-LB is shipped with a sticker with the default device EUI as below:199 +Each SW3L-LB is shipped with a sticker with the default device EUI as below: 176 176 177 177 [[image:image-20230426084152-1.png||alt="图片-20230426084152-1.png" height="233" width="502"]] 178 178 ... ... @@ -201,10 +201,10 @@ 201 201 [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LSN50v2-S31-S31B%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20User%20Manual/WebHome/image-20220611161308-6.png?width=744&height=485&rev=1.1||alt="图片-20220611161308-6.png"]] 202 202 203 203 204 -(% style="color:blue" %)**Step 2:**(%%) Activate on CPL03-LB228 +(% style="color:blue" %)**Step 2:**(%%) Activate on SW3L-LB 205 205 206 206 207 -Press the button for 5 seconds to activate the CPL03-LB.231 +Press the button for 5 seconds to activate the SW3L-LB. 208 208 209 209 (% style="color:green" %)**Green led**(%%) will fast blink 5 times, device will enter (% style="color:blue" %)**OTA mode**(%%) for 3 seconds. And then start to JOIN LoRaWAN network. (% style="color:green" %)**Green led**(%%) will solidly turn on for 5 seconds after joined in network. 210 210 ... ... @@ -216,8 +216,10 @@ 216 216 === 2.3.1 Device Status, FPORT~=5 === 217 217 218 218 219 - Users cansethedownlinkcommand(**0x2601**)toaskCPL03-LBtosenddeviceconfiguredetail,includedeviceconfigurestatus.CPL03-LB will uplinka payloadviaFPort=5toserver.243 +Include device configure status. Once SW3L-LB Joined the network, it will uplink this message to the server. After that, SW3L-LB will uplink Device Status every 12 hours. 220 220 245 +Users can use the downlink command(**0x26 01**) to ask SW3L-LB to send device configure detail, include device configure status. SW3L-LB will uplink a payload via FPort=5 to server. 246 + 221 221 The Payload format is as below. 222 222 223 223 ... ... @@ -228,10 +228,10 @@ 228 228 229 229 Example parse in TTNv3 230 230 231 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/ CPL01%20LoRaWAN%20Outdoor%20PulseContact%20%20Sensor%20Manual/WebHome/1652859749264-179.png?width=723&height=275&rev=1.1||alt="1652859749264-179.png"]]257 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/SW3L%20LoRaWAN%20Outdoor%20Flow%20Sensor/WebHome/1652925144491-755.png?width=732&height=139&rev=1.1||alt="1652925144491-755.png"]] 232 232 233 233 234 -(% style="color:#037691" %)**Sensor Model**(%%): For CPL03-LB, this value is 0x0A260 +(% style="color:#037691" %)**Sensor Model**(%%): For SW3L-LB, this value is 0x11 235 235 236 236 (% style="color:#037691" %)**Firmware Version**(%%): 0x0100, Means: v1.0.0 version 237 237 ... ... @@ -287,106 +287,74 @@ 287 287 === 2.3.2 Sensor Configuration, FPORT~=4 === 288 288 289 289 290 - CPL03-LBwill only send this command after getting the downlink command (0x26 02) from the server.316 +SW3L will only send this command after getting the downlink command (0x26 02) from the server. 291 291 292 -(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %) 293 -|(% colspan="6" style="background-color:#d9e2f3; color:#0070c0; width:504px" %)**Sensor Configuration FPORT=4** 294 -|**Size(bytes)**|(% style="width:75px" %)**3**|(% style="width:77px" %)**1**|(% style="width:96px" %)**1**|(% style="width:158px" %)**2**|(% style="width:158px" %)**1** 295 -|**Value**|(% style="width:75px" %)TDC (unit:sec)|(% style="width:77px" %)Disalarm|(% style="width:96px" %)Keep status|(% style="width:158px" %)Keep time (unit: sec)|(% style="width:158px" %)Trigger mode 318 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:510px" %) 319 +|(% style="background-color:#d9e2f3; color:#0070c0; width:70px" %) **Size(bytes)**|(% style="background-color:#d9e2f3; color:#0070c0; width:105px" %)**3**|(% style="background-color:#d9e2f3; color:#0070c0; width:60px" %)**1**|(% style="background-color:#d9e2f3; color:#0070c0; width:96px" %)**1**|(% style="background-color:#d9e2f3; color:#0070c0; width:105px" %)**2**|(% style="background-color:#d9e2f3; color:#0070c0; width:74px" %)**1** 320 +|**Value**|(% style="width:104px" %)TDC(unit:sec)|(% style="width:43px" %)N/A|(% style="width:91px" %)Stop Timer|(% style="width:100px" %)Alarm Timer|(% style="width:69px" %)Reserve 296 296 297 -* ((( 298 -(% style="color:#037691" %)** TDC: (default: 0x001C20)** 299 -))) 322 +* (% style="color:#037691" %)**TDC: (default: 0x0004B0)** 300 300 301 -((( 302 -Uplink interval for the total pulse count, default value is 0x001C20 which is 7200 seconds = 2 hours. 324 +Uplink interval for the total pulse count, default value is 0x0004B0 which is 1200 seconds = 20 minutes. 303 303 304 - 305 -))) 306 306 307 -* ((( 308 -(% style="color:#037691" %)** Disalarm: (default: 0)** 309 -))) 327 +* (% style="color:#037691" %)**STOP Duration & Alarm Timer** 310 310 311 -((( 312 -(% style="color:blue" %)** If Disalarm = 1**(%%), CPL03-LB will only send uplink at every TDC periodically. This is normally use for pulse meter application, in this application, there are many disconnect/connect event, and platform only care about the total number of pulse. 313 -))) 329 +Shows the configure value of [[Alarm for continuously water flow>>||anchor="H3.4Alarmforcontinuouslywaterflow"]] 314 314 315 -((( 316 -(% style="color:blue" %)** If Disalarm = 0**(%%), CPL03-LB will send uplink at every TDC periodically. 331 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/SW3L%20LoRaWAN%20Outdoor%20Flow%20Sensor/WebHome/image-20220519095747-2.png?width=723&height=113&rev=1.1||alt="image-20220519095747-2.png"]] 317 317 318 - 319 -))) 320 320 321 -* ((( 322 -(% style="color:#037691" %)** Keep Status & Keep Time** 323 -))) 334 +=== 2.3.3 Water Flow Value, Uplink FPORT~=2 === 324 324 325 -((( 326 -Shows the configure value of [[Alarm Base on Timeout Feature>>||anchor="H3.3.5AlarmBaseonTimeout"]] 327 327 328 - 337 +((( 338 +SW3L will send this uplink **after** Device Status once join the LoRaWAN network successfully. And SW3L will: 329 329 ))) 330 330 331 -* ((( 332 -(% style="color:#037691" %)** Trigger mode (default: 0)** 333 -))) 334 - 335 335 ((( 336 - (% style="color:blue"%)**If Trigger mode= 0**(%%),count closetoopennt.342 +periodically send this uplink every 20 minutes, this interval [[can be changed>>||anchor="H3.1SetTransmitIntervalTime"]]. 337 337 ))) 338 338 339 339 ((( 340 - (%style="color:blue" %)** If Trigger mode= 1**(%%), countpento closeevent.346 +Uplink Payload totals 11 bytes. 341 341 ))) 342 342 343 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/CPL01%20LoRaWAN%20Outdoor%20PulseContact%20%20Sensor%20Manual/WebHome/1652860064987-743.png?width=730&height=152&rev=1.1||alt="1652860064987-743.png"]] 349 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:510px" %) 350 +|=(% colspan="6" style="width: 510px;background-color:#D9E2F3;color:#0070C0" %)**Water Flow Value, FPORT=2** 351 +|(% style="width:60px" %)**Size(bytes)**|(% style="width:130px" %)**1**|(% style="width:130px" %)**4**|(% style="width:30px" %)**1**|(% style="width:50px" %)**1**|(% style="width:80px" %)**4** 352 +|(% style="width:110px" %)**Value**|(% style="width:81px" %)Calculate Flag & [[Alarm>>||anchor="H3.4Alarmforcontinuouslywaterflow"]]|(% style="width:95px" %)((( 353 +Total pulse Or Last Pulse 354 +)))|(% style="width:55px" %)MOD|(% style="width:115px" %)Reserve(0x01)|(% style="width:129px" %)[[Unix TimeStamp>>||anchor="H2.4.1UnixTimeStamp"]] 344 344 356 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:470px" %) 357 +|=(% colspan="4" style="width: 470px;background-color:#D9E2F3;color:#0070C0" %)**Status & Alarm field** 358 +|(% style="width:60px" %)**Size(bit)**|(% style="width:80px" %)**6**|(% style="width:310px" %)**1**|(% style="width:20px" %)**1** 359 +|(% style="width:88px" %)**Value**|(% style="width:117px" %)Calculate Flag|(% style="width:221px" %)Alarm: 0: No Alarm; 1: Alarm|(% style="width:64px" %)N/A 345 345 346 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/ CPL01%20LoRaWAN%20Outdoor%20PulseContact%20%20Sensor%20Manual/WebHome/1652860079526-831.png?width=729&height=209&rev=1.1||alt="1652860079526-831.png"]]361 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/SW3L%20LoRaWAN%20Outdoor%20Flow%20Sensor/WebHome/image-20220519095946-3.png?width=736&height=284&rev=1.1||alt="image-20220519095946-3.png"]] 347 347 348 348 349 -=== 2.3.3 Real-Time Open/Close Status, Uplink FPORT~=2 === 350 - 351 - 352 -((( 353 -((( 354 -CPL03-LB will send this uplink **after** Device Status once join the LoRaWAN network successfully. And CPL03-LB will: 364 +* ((( 365 +(% style="color:#037691" %)**Calculate Flag** 355 355 ))) 356 -))) 357 357 358 358 ((( 359 -((( 360 -periodically send this uplink every 2 hours, this interval [[can be changed>>||anchor="H3.3.1SetTransmitIntervalTime"]]. 369 +The calculate flag is a user defined field, IoT server can use this flag to handle different meters with different pulse factors. For example, if there are 100 Flow Sensors, meters 1 ~~50 are 1 liter/pulse and meters 51 ~~ 100 has 1.5 liter/pulse. 361 361 ))) 362 -))) 363 363 364 364 ((( 365 -((( 366 -Uplink Payload totals 11 bytes. 373 +**Example: in the default payload:** 367 367 ))) 368 -))) 369 369 370 -(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:520px" %) 371 -|=(% colspan="5" style="background-color:#D9E2F3;color:#0070C0; width: 520px;" %)**Real-Time Open/Close Status, FPORT=2** 372 -|(% style="width:60px" %)**Size(bytes)**|(% style="width:65px" %)**1**|(% style="width:65px" %)**3**|(% style="width:240px" %)**3**|(% style="width:90px" %)**4** 373 -|(% style="width:101px" %)**Value**|(% style="width:133px" %)Status & [[Alarm>>||anchor="H3.3.5AlarmBaseonTimeout"]]|(% style="width:92px" %)Total pulse|(% style="width:247px" %)The last open duration (unit: min)|(% style="width:149px" %)[[Unix TimeStamp>>||anchor="H2.5.2UnixTimeStamp"]] 374 - 375 -(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:504px" %) 376 -|=(% colspan="4" style="background-color:#D9E2F3;color:#0070C0; width: 502px;" %)**Status & Alarm field** 377 -|(% style="width:60px" %)**Size(bit)**|(% style="width:70px" %)**6**|(% style="width:228px" %)**1**|(% style="width:146px" %)**1** 378 -|(% style="width:76px" %)Value|(% style="width:80px" %)Calculate Flag|(% style="width:208px" %)Alarm: 0: No Alarm; 1: Alarm|(% style="width:136px" %)Contact Status: 0: Open, 1: Close 379 - 380 380 * ((( 381 - (% style="color:#037691"%)** CalculateFlag**377 +calculate flag=0: for SW3L-004 Flow Sensor: 450 pulse = 1 L 382 382 ))) 383 - 384 -((( 385 -The calculate flag is a user define field, IoT server can use this filed to handle different meter with different pulse factor. For example, if there are 100 water meters, meter 1 ~~50 are 1 liter/pulse and meter 51 ~~ 100 has 1.5 liter/pulse. 379 +* ((( 380 +calculate flag=1: for SW3L-006 Flow Sensor: 390 pulse = 1 L 386 386 ))) 387 - 388 -((( 389 -User can set calculate flag to 1 for meter 1~~50 and 2 for meter 51 ~~ 100, So IoT Server can use this field for calculation. 382 +* ((( 383 +calculate flag=2: for SW3L-010 Flow Sensor: 64 pulse = 1 L 390 390 ))) 391 391 392 392 ((( ... ... @@ -395,167 +395,96 @@ 395 395 396 396 ((( 397 397 Range (6 bits): (b)000000 ~~ (b) 111111 392 + 393 +If user use with a meter for example is 0.02L/pulse. To proper decode the correct value in server, 394 + 395 +1) User can set the Calculate Flag of this sensor to 3. 396 + 397 +2) In server side, when a sensor data arrive, the decoder will check the value of Calculate Flag, It the value is 3, the total volume = 0.02 x Pulse Count. 398 398 ))) 399 399 400 400 ((( 401 -Refer: [[Set Calculate Flag>>||anchor="H3.3.8Setthecalculateflag"]] 402 - 403 - 401 +(% style="color:red" %)**NOTE: User need to set Calculate Flag to proper value before use Flow Sensor. Downlink or AT Command see: **(%%)Refer: [[Set Calculate Flag>>||anchor="H3.6Setthecalculateflag"]] 404 404 ))) 405 405 406 406 * ((( 407 -(% style="color:#037691" %)** 405 +(% style="color:#037691" %)**Alarm** 408 408 ))) 409 409 410 410 ((( 411 -See [[Alarm Base on Timeout>>||anchor="H3.3.5AlarmBaseonTimeout"]] 412 - 413 - 409 +See [[Alarm for continuously water flow>>||anchor="H3.4Alarmforcontinuouslywaterflow"]] 414 414 ))) 415 415 412 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/SW3L%20LoRaWAN%20Outdoor%20Flow%20Sensor/WebHome/image-20220519095946-4.png?width=724&height=65&rev=1.1||alt="image-20220519095946-4.png"]] 413 + 414 + 416 416 * ((( 417 -(% style="color:#037691" %)** ContactStatus**416 +(% style="color:#037691" %)**Total pulse** 418 418 ))) 419 419 420 420 ((( 421 - 0:Open420 +Total pulse/counting since factory 422 422 ))) 423 423 424 424 ((( 425 -1: Close 426 - 427 - 424 +Range (4 Bytes) : 0x00000000~~ 0xFFFFFFFF . 428 428 ))) 429 429 430 430 * ((( 431 -(% style="color:#037691" %)** Totalpulse**428 +(% style="color:#037691" %)**Last Pulse** 432 432 ))) 433 433 434 434 ((( 435 -Total pulse /countingbase ondry [[contact triggerevent>>||anchor="H2.3.2SensorConfiguration2CFPORT3D4"]]432 +Total pulse since last FPORT=2 uplink. (Default 20 minutes) 436 436 ))) 437 437 438 438 ((( 439 -Range (3 Bytes) : 0x000000 ~~ 0xFFFFFF . Max: 16777215 440 - 441 - 436 +Range (4 Bytes) : 0x00000000~~ 0xFFFFFFFF . 442 442 ))) 443 443 444 444 * ((( 445 -(% style="color:#037691" %)** Thelast open duration**440 +(% style="color:#037691" %)**MOD: Default =0** 446 446 ))) 447 447 448 448 ((( 449 -D ryContactlast openduration.444 +MOD=0 ~-~-> Uplink Total Pulse since factory 450 450 ))) 451 451 452 452 ((( 453 -Unit :min.448 +MOD=1 ~-~-> Uplink total pulse since last FPORT=2 uplink. 454 454 ))) 455 455 456 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/CPL01%20LoRaWAN%20Outdoor%20PulseContact%20%20Sensor%20Manual/WebHome/1652860403792-491.png?width=735&height=153&rev=1.1||alt="1652860403792-491.png"]] 451 +* ((( 452 +(% style="color:#037691" %)**Water Flow Value** 453 +))) 457 457 455 +((( 456 +**Total Water Flow Volume = (Calculate Flag) x (Total Pulse)=9597/450=21.3L** 457 +))) 458 458 459 - === 2.3.4 Real-TimeOpen/CloseStatus,3pulsemode, Uplink FPORT~=6===459 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/SW3L%20LoRaWAN%20Outdoor%20Flow%20Sensor/WebHome/image-20220519095946-5.png?width=727&height=50&rev=1.1||alt="image-20220519095946-5.png"]] 460 460 461 461 462 -(% style="color:red" %)**Note:** 463 - 464 -* Firmware support for this mode is not released. If users want to test, please contact Dragino support. 465 -* Users need to run (% style="color:blue" %)**AT+MOD=3**(%%) to support this model after updating the firmware. 466 -* This mode doesn't support Historical Events and Datalog features. 467 - 468 -(% style="color:blue" %)**CPL03-LB 3 Pulse Wiring:** 469 - 470 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/CPL01%20LoRaWAN%20Outdoor%20PulseContact%20%20Sensor%20Manual/WebHome/image-20221013153352-1.png?width=720&height=628&rev=1.1||alt="image-20221013153352-1.png"]] 471 - 472 - 473 -(% style="color:blue" %)**Payload:** 474 - 475 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/CPL01%20LoRaWAN%20Outdoor%20PulseContact%20%20Sensor%20Manual/WebHome/image-20221013153352-2.png?width=1215&height=167&rev=1.1||alt="image-20221013153352-2.png"]] 476 - 477 - 478 -(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:447px" %) 479 -|(% style="background-color:#d9e2f3; color:#0070c0; width:95px" %)**Size(bytes)**|(% style="background-color:#d9e2f3; color:#0070c0; width:61px" %)**1**|(% style="background-color:#d9e2f3; color:#0070c0; width:98px" %)**3**|(% style="background-color:#d9e2f3; color:#0070c0; width:98px" %)**3**|(% style="background-color:#d9e2f3; color:#0070c0; width:95px" %)**3** 480 -|(% style="width:93px" %)Value|(% style="width:59px" %)Status|(% style="width:98px" %)((( 481 -Port1 Total Pulse(PB14) 482 -)))|(% style="width:96px" %)((( 483 -Port2 Total Pulse(PB15) 484 -)))|(% style="width:94px" %)((( 485 -Port3 Total Pulse(PA4) 462 +((( 463 +**Total Water Flow for TDC timer = (Calculate Flag) x (Last Pulse)=79/450=0.2L** 486 486 ))) 487 487 488 - (% style="color:blue"%)**Status:**466 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/SW3L%20LoRaWAN%20Outdoor%20Flow%20Sensor/WebHome/image-20220519095946-6.png?width=733&height=43&rev=1.1||alt="image-20220519095946-6.png"]] ** ** 489 489 490 -(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:257px" %) 491 -|(% style="background-color:#d9e2f3; color:#0070c0; width:75px" %)**Size(bit)**|(% style="background-color:#d9e2f3; color:#0070c0; width:112px" %)**6**|(% style="background-color:#d9e2f3; color:#0070c0; width:70px" %)**2** 492 -|(% style="width:75px" %)Value|(% style="width:111px" %)Calculate Flag|(% style="width:68px" %)Reserve 493 493 494 - (%style="color:red" %)**MaxCOUNT for each portis 16777215. Exceed this numberwillreseto1.**469 +=== 2.3.4 Historical Water Flow Status, FPORT~=3 === 495 495 496 496 497 -(% style="color:blue" %)**Related AT Command:** 498 - 499 -(% style="color:#037691" %)**AT+TTRMOD1: Port1 count mode; 0: Signal falling edge(Default), 1: Signal raising edge** 500 - 501 - AT+TTRMOD1=0 Downlink Command: 0xA4 01 00 502 - 503 - AT+TTRMOD1=1 Downlink Command: 0xA4 01 01 504 - 505 - 506 -(% style="color:#037691" %)**AT+TTRMOD2: Port2 count mode; 0: Signal falling edge(Default), 1: Signal raising edge** 507 - 508 - AT+TTRMOD1=0 Downlink Command: 0xA4 02 00 509 - 510 - AT+TTRMOD1=1 Downlink Command: 0xA4 02 01 511 - 512 - 513 -(% style="color:#037691" %)**AT+TTRMOD3: Port3 count mode; 0: Signal falling edge(Default), 1: Signal raising edge** 514 - 515 - AT+TTRMOD1=0 Downlink Command: 0xA4 03 00 516 - 517 - AT+TTRMOD1=1 Downlink Command: 0xA4 03 01 518 - 519 - 520 -(% style="color:#037691" %)**AT+CALCFLAG: Calculate Flag ( Default : 0 )** 521 - 522 - AT+CALCFLAG=aa 523 - 524 - 525 -(% style="color:blue" %)**Downlink Command: 0xA5 aa** 526 - 527 -(% style="color:#037691" %)**AT+COUNTMOD: Accumulative Mode; 0: Accumulative (Default),1: Reset after uplink.** 528 - 529 - AT+COUNTMOD=0 Downlink Command: 0x0B 00 530 - 531 - AT+COUNTMOD=1 Downlink Command: 0x0B 01 532 - 533 - 534 -(% style="color:#037691" %)**AT+SETCNT: Set count value** 535 - 536 - AT+SETCNT=1,aa Downlink Command: 0xA6 01 aa aa aa 537 - 538 - AT+SETCNT=2,aa Downlink Command: 0xA6 02 aa aa aa 539 - 540 - AT+SETCNT=3,aa Downlink Command: 0xA6 03 aa aa aa 541 - 542 - 543 -(% style="color:blue" %)**Decode: **(%%)[[https:~~/~~/github.com/dragino/dragino-end-node-decoder>>https://github.com/dragino/dragino-end-node-decoder]] 544 - 545 - 546 -=== 2.3.5 Historical Door Open/Close Event, FPORT~=3 === 547 - 548 - 549 549 ((( 550 - CPL03-LBstores sensor values and users can retrieve these history values via the [[downlink command>>||anchor="H2.5DatalogFeature"]].473 +SW3L stores sensor values and users can retrieve these history values via the [[downlink command>>||anchor="H2.4DatalogFeature"]]. 551 551 ))) 552 552 553 553 ((( 554 -The historical payload includes one or multiplies entries and every entry has the same payload as Real-Time open/closestatus.477 +The historical payload includes one or multiplies entries and every entry has the same payload as Real-Time water flow status. 555 555 ))) 556 556 557 557 * ((( 558 -Each data entry is 11 bytes and has the same structure as [[ Real-Timeopen/closestatus>>||anchor="H2.3.3Real-TimeOpen2FCloseStatus2CUplinkFPORT3D2"]], to save airtime and battery,CPL03-LBwill send max bytes according to the current DR and Frequency bands.481 +Each data entry is 11 bytes and has the same structure as [[real time water flow status>>||anchor="H2.3.3A0WaterFlowValue2CUplinkFPORT3D2"]], to save airtime and battery, SW3L will send max bytes according to the current DR and Frequency bands. 559 559 ))) 560 560 561 561 ((( ... ... @@ -563,101 +563,80 @@ 563 563 ))) 564 564 565 565 ((( 566 -a) (% style="color:blue" %)**DR0**(%%):max is 11 bytes so one entry of data489 +**a) DR0:** max is 11 bytes so one entry of data 567 567 ))) 568 568 569 569 ((( 570 -b) (% style="color:blue" %)**DR1**(%%):max is 53 bytes so devices will upload 4 entries of data (total 44 bytes)493 +**b) DR1:** max is 53 bytes so devices will upload 4 entries of data (total 44 bytes) 571 571 ))) 572 572 573 573 ((( 574 -c) (% style="color:blue" %)**DR2**(%%):total payload includes 11 entries of data497 +**c) DR2:** total payload includes 11 entries of data 575 575 ))) 576 576 577 577 ((( 578 -d) (% style="color:blue" %)**DR3**(%%):total payload includes 22 entries of data.501 +**d) DR3:** total payload includes 22 entries of data. 579 579 ))) 580 580 581 581 ((( 582 -If CPL03-LB doesn't have any data in the polling time. It will uplink 11 bytes of 0 583 - 584 - 505 +If SW3L doesn't have any data in the polling time. It will uplink 11 bytes of 0 585 585 ))) 586 586 587 -(% style="color:blue" %)** Downlink:** 588 - 589 -(% class="box" %) 590 590 ((( 591 - **0x3161 E93A D4 61E9 3DE0 05**509 +(% style="color:#037691" %)**Downlink:** 592 592 ))) 593 593 594 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/CPL01%20LoRaWAN%20Outdoor%20PulseContact%20%20Sensor%20Manual/WebHome/1652861353248-624.png?width=720&height=189&rev=1.1||alt="1652861353248-624.png"]] 595 - 596 - 597 -(% style="color:blue" %)** Uplink:** 598 - 599 -(% class="box" %) 600 600 ((( 601 - **0E 00 23E6 00 00 00 61E9 3B 04 0E 0023E600 00 00 61 E9 3B25 0D 00 00 00 00 00 00 61E9 3B C80E00 00 0200 00 00 61 E9 3B D40E 00 00 0600 00 00 61 E9 3BDB 01 00 00 00 00 00 00 61 E93C9101 00 00 00 00 00 00 61 E9 3C A1 0D 00 00 00 00 00 00 61 E9 3C BC 0E 00 00 0700 00 00 61 E9 3C D6 00 00 00 00 00 00 00 61 E9 3D A6**513 +0x31 62 46 B1 F0 62 46 B3 94 07 602 602 ))) 603 603 604 - (%style="color:#037691"%)****516 +[[image:1652926690850-712.png||_mstalt="295178" height="115" width="726"]] 605 605 606 -(% style="color:#037691" %)**Parsed Value:** 607 607 608 608 ((( 609 - [ALARM,PIN_STATUS,TOTAL_PULSE, CALCULATE_FLAG, LAST_OPEN_DURATION, TIME]520 +(% style="color:#037691" %)**Uplink:** 610 610 ))) 611 611 612 612 ((( 613 - 524 +00 00 01 00 00 00 00 62 46 B2 26 00 00 01 00 00 00 00 62 46 B2 5D 00 00 01 00 00 00 00 62 46 B2 99 00 00 01 00 00 00 00 62 46 B2 D5 00 00 01 00 00 01 15 62 46 B3 11 00 00 01 00 00 01 1F 62 46 B3 7E 614 614 ))) 615 615 616 616 ((( 617 - [TRUE,CLOSE, 9190,3, 0, 2022-01-2010:35:48],528 +(% style="color:#037691" %)**Parsed Value:** 618 618 ))) 619 619 620 620 ((( 621 -[ TRUE, CLOSE,9190,3,0,2022-01-2010:36:21],532 +[Alarm, Calculate Flag, MOD, Total pulse or Last Pulse,** **Water Flow Value, TIME] 622 622 ))) 623 623 624 -((( 625 -[FALSE, OPEN, 0, 3, 0, 2022-01-20 10:39:04], 626 -))) 627 627 628 628 ((( 629 -[ TRUE, CLOSE,2,3,1-2039:16],537 +[FALSE,0,0,0,0.0,2022-04-01 08:04:54], 630 630 ))) 631 631 632 632 ((( 633 -[ TRUE, CLOSE,6,3,1-2039:23],541 +[FALSE,0,0,0,0.0,2022-04-01 08:05:49], 634 634 ))) 635 635 636 636 ((( 637 -[FALSE, OPEN,1-2042:25],545 +[FALSE,0,0,0,0.0,2022-04-01 08:06:49], 638 638 ))) 639 639 640 640 ((( 641 -[FALSE, OPEN,1-2042:41],549 +[FALSE,0,0,0,0.0,2022-04-01 08:07:49], 642 642 ))) 643 643 644 644 ((( 645 -[FALSE, OPEN,3,1-2043:08],553 +[FALSE,0,0,277,0.6,2022-04-01 08:08:49], 646 646 ))) 647 647 648 648 ((( 649 -[ TRUE, CLOSE,7,3,1-20 10:43:34],557 +[FALSE,0,0,287,0.6,2022-04-01 08:10:38], 650 650 ))) 651 651 652 -((( 653 -[FALSE, CLOSE, 0, 0, 0, 2022-01-20 10:47:02], 560 +[[image:1652926777796-267.png||_mstalt="300183" height="279" width="724"]] 654 654 655 - 656 -))) 657 657 658 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/CPL01%20LoRaWAN%20Outdoor%20PulseContact%20%20Sensor%20Manual/WebHome/1652861480446-216.png?rev=1.1||alt="1652861480446-216.png"]] 659 - 660 - 661 661 == 2.4 Payload Decoder file == 662 662 663 663 ... ... @@ -762,7 +762,6 @@ 762 762 * AT Command via UART Connection : See [[UART Connection>>http://wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H2.3UARTConnectionforSN50v3basemotherboard]]. 763 763 * LoRaWAN Downlink. Instruction for different platforms: See [[IoT LoRaWAN Server>>http://wiki.dragino.com/xwiki/bin/view/Main/]] section. 764 764 765 - 766 766 == 3.2 General Commands == 767 767 768 768 ... ... @@ -1004,7 +1004,6 @@ 1004 1004 1005 1005 * **Example**: 0xA401 ~/~/ Same as AT+ TTRMOD =1 1006 1006 1007 - 1008 1008 === 3.3.8 Set the calculate flag === 1009 1009 1010 1010 ... ... @@ -1021,7 +1021,6 @@ 1021 1021 1022 1022 * **Example**: 0XA501 ~/~/ Same as AT+CALCFLAG =1 1023 1023 1024 - 1025 1025 === 3.3.9 Set count number === 1026 1026 1027 1027 ... ... @@ -1040,7 +1040,6 @@ 1040 1040 1041 1041 * **Example**: 0xA6000064 ~/~/ Same as AT+ SETCNT =100 1042 1042 1043 - 1044 1044 === 3.3.10 Set Interrupt Mode === 1045 1045 1046 1046 ... ... @@ -1075,7 +1075,6 @@ 1075 1075 1076 1076 * Example 2: Downlink Payload: 06000003 ~/~/ Set the interrupt mode to rising edge trigger 1077 1077 1078 - 1079 1079 === 3.3.11 Set Power Output Duration === 1080 1080 1081 1081 ... ... @@ -1105,7 +1105,6 @@ 1105 1105 1106 1106 * Example 2: Downlink Payload: 0701F4 **~-~-->** AT+5VT=500 1107 1107 1108 - 1109 1109 = 4. Battery & Power Consumption = 1110 1110 1111 1111 ... ... @@ -1134,7 +1134,6 @@ 1134 1134 1135 1135 * Update through UART TTL interface. **[[Instruction>>url:http://wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H1.LoRaSTv4baseHardware]]**. 1136 1136 1137 - 1138 1138 = 6. FAQ = 1139 1139 1140 1140 == 6.1 AT Commands input doesn't work == ... ... @@ -1166,7 +1166,6 @@ 1166 1166 1167 1167 * (% style="color:red" %)**CN470**(%%): LoRaWAN CN470 band 1168 1168 1169 - 1170 1170 = 8. Packing Info = 1171 1171 1172 1172 ... ... @@ -1184,7 +1184,6 @@ 1184 1184 1185 1185 * Weight / pcs : g 1186 1186 1187 - 1188 1188 = 9. Support = 1189 1189 1190 1190
- image-20230530140053-1.jpeg
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +1.3 MB - Content