Changes for page DS20L -- LoRaWAN Smart Distance Detector User Manual 01
Last modified by Mengting Qiu on 2023/12/14 11:15
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 14 added, 0 removed)
- image-20230530135929-2.png
- image-20230530140053-1.jpeg
- image-20230612170349-1.png
- image-20230612170943-2.png
- image-20230612171032-3.png
- image-20230613100900-1.png
- image-20230613102426-2.png
- image-20230613102459-3.png
- image-20230613133647-1.png
- image-20230613133716-2.png
- image-20230613140115-3.png
- image-20230613140140-4.png
- image-20230613143052-5.png
- image-20230613143125-6.png
Details
- Page properties
-
- Title
-
... ... @@ -1,1 +1,1 @@ 1 -S W3L-LB_LoRaWAN_Flow_Sensor_User_Manual1 +DDS20-LB -- LoRaWAN Ultrasonic Liquid Level Sensor User Manual - Content
-
... ... @@ -1,7 +1,13 @@ 1 1 (% style="text-align:center" %) 2 -[[image:image-20230 530084608-2.jpeg||height="707" width="707"]]2 +[[image:image-20230613133716-2.png||height="717" width="717"]] 3 3 4 4 5 + 6 + 7 + 8 + 9 + 10 + 5 5 **Table of Contents:** 6 6 7 7 {{toc/}} ... ... @@ -13,29 +13,26 @@ 13 13 14 14 = 1. Introduction = 15 15 16 -== 1.1 What is CPL03-LB LoRaWANPulse/ContactSensor ==22 +== 1.1 What is LoRaWAN Ultrasonic liquid level Sensor == 17 17 18 18 19 -The Dragino CPL03-LB is a (% style="color:blue" %)**LoRaWANContactSensor**(%%) for Internet of Things solution. Itdetects drycontactstatus,open time,open counts, andthenupload to IoT servervia LoRaWAN wirelessprotocol.25 +The Dragino DDS20-LB is a (% style="color:blue" %)**LoRaWAN Ultrasonic liquid level sensor**(%%) for Internet of Things solution. It uses (% style="color:blue" %)**none-contact method **(%%)to measure the (% style="color:blue" %)**height of liquid**(%%) in a container without opening the container, and send the value via LoRaWAN network to IoT Server. 20 20 21 -The CPL03-LBwillsend periodicallydataeveryday as well as foreachdrycontact action.Italso countsthecontactopentimesandcalculatelast openduration.Usercanalsodisable theuplink foreachopen/closeevent,instead,device can counteach openeventanduplinkperiodically.27 +The DDS20-LB sensor is installed directly below the container to detect the height of the liquid level. User doesn't need to open a hole on the container to be tested. The none-contact measurement makes the measurement safety, easier and possible for some strict situation. 22 22 23 - TheLoRawireless technologyusedinCPL03-LBallowsdeviceto senddataandreachextremelylongrangesatw data-rates.Itprovidesultra-longrangespread spectrumcommunicationandhighinterferenceimmunitywhilstminimizingcurrent consumption.29 +DDS20-LB uses (% style="color:blue" %)**ultrasonic sensing technology**(%%) for distance measurement. DDS20-LB is of high accuracy to measure various liquid such as: (% style="color:blue" %)**toxic substances**(%%), (% style="color:blue" %)**strong acids**(%%), (% style="color:blue" %)**strong alkalis**(%%) and (% style="color:blue" %)**various pure liquids**(%%) in high-temperature and high-pressure airtight containers. 24 24 25 - CPL03-LB(%style="color:blue"%)**supportsopen alarmfeature**(%%), usercanset open alarmforinstantnotice.CPL03-LB (% style="color:blue"%)**supportsDatalogfeature**(%%),it cansavethedatawhenthere isno LoRaWAN networkand uplinkwhennetworkrecover.31 +The LoRa wireless technology used in DDS20-LB allows device to send data and reach extremely long ranges at low data-rates. It provides ultra-long range spread spectrum communication and high interference immunity whilst minimizing current consumption. 26 26 27 - CPL03-LBisdesigned foroutdoorse.It hasa weatherproofenclosureindustriallevelatterytoworkinlowtohightemperatures.33 +DDS20-LB (% style="color:blue" %)**supports BLE configure**(%%) and (% style="color:blue" %)**wireless OTA update**(%%) which make user easy to use. 28 28 29 - CPL03-LB(%style="color:blue"%)**supports BLE configure**(%%) and (% style="color:blue" %)**wirelessOTAupdate**(%%)whichmakeuser easytouse.35 +DDS20-LB is powered by (% style="color:blue" %)**8500mAh Li-SOCI2 battery**(%%), it is designed for long term use up to 5 years. 30 30 31 - CPL03-LB is poweredby (%style="color:blue"%)**8500mAhLi-SOCI2battery**(%%), itisdesignedforlongtermuseupto5years.37 +Each DDS20-LB is pre-load with a set of unique keys for LoRaWAN registrations, register these keys to local LoRaWAN server and it will auto connect after power on. 32 32 33 - Each CPL03-LBis pre-load with a set of unique keys for LoRaWAN registrations, register these keys to local LoRaWAN server andit will auto connect after power on.39 +[[image:image-20230613140115-3.png||height="453" width="800"]] 34 34 35 35 36 -[[image:image-20230530111051-3.png||height="402" width="850"]] 37 - 38 - 39 39 == 1.2 Features == 40 40 41 41 ... ... @@ -42,19 +42,18 @@ 42 42 * LoRaWAN 1.0.3 Class A 43 43 * Bands: CN470/EU433/KR920/US915/EU868/AS923/AU915/IN865 44 44 * Ultra-low power consumption 45 -* Open/Closedetect46 -* Open/Closestatistics47 -* Temperature& Humidityalarm48 -* supports openalarmfeature49 -* supports Datalogfeature48 +* Liquid Level Measurement by Ultrasonic technology 49 +* Measure through container, No need to contact Liquid 50 +* Valid level range 20mm - 2000mm 51 +* Accuracy: ±(5mm+S*0.5%) (S: Measure Value) 52 +* Cable Length : 25cm 50 50 * Support Bluetooth v5.1 and LoRaWAN remote configure 51 51 * Support wireless OTA update firmware 52 -* Uplinkonperiodically andopen/close event55 +* AT Commands to change parameters 53 53 * Downlink to change configure 57 +* IP66 Waterproof Enclosure 54 54 * 8500mAh Battery for long term use 55 55 56 - 57 - 58 58 == 1.3 Specification == 59 59 60 60 ... ... @@ -83,609 +83,418 @@ 83 83 * Sleep Mode: 5uA @ 3.3v 84 84 * LoRa Transmit Mode: 125mA @ 20dBm, 82mA @ 14dBm 85 85 88 +== 1.4 Suitable Container & Liquid == 86 86 87 87 88 -== 1.4 Applications == 91 +* Solid Wall container such as: steel, iron, glass, ceramics, non-foaming plastics etc. 92 +* Container shape is regular, and surface is smooth. 93 +* Container Thickness: 94 +** Pure metal material. 2~~8mm, best is 3~~5mm 95 +** Pure non metal material: <10 mm 96 +* Pure liquid without irregular deposition.(% style="display:none" %) 89 89 98 +== 1.5 Install DDS20-LB == 90 90 91 -* Open/Close Detection 92 -* Pulse meter application 93 -* Dry Contact Detection 94 94 101 +(% style="color:blue" %)**Step 1**(%%): Choose the installation point. 95 95 103 +DDS20-LB (% style="color:red" %)**MUST**(%%) be installed on the container bottom middle position. 96 96 97 - == 1.5 Sleepworkingmode105 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDDS20%20-%20LoRaWAN%20Liquid%20Level%20Sensor%20User%20Manual/WebHome/image-20220615091045-3.png?rev=1.1||alt="image-20220615091045-3.png"]] 98 98 99 99 100 -(% style="color:blue" %)**Deep Sleep Mode: **(%%)Sensor doesn't have any LoRaWAN activate. This mode is used for storage and shipping to save battery life. 108 +((( 109 +(% style="color:blue" %)**Step 2**(%%): Polish the installation point. 110 +))) 101 101 102 -(% style="color:blue" %)**Working Mode:** (%%)In this mode, Sensor will work as LoRaWAN Sensor to Join LoRaWAN network and send out sensor data to server. Between each sampling/tx/rx periodically, sensor will be in IDLE mode), in IDLE mode, sensor has the same power consumption as Deep Sleep mode. 112 +((( 113 +For Metal Surface with paint, it is important to polish the surface, first use crude sand paper to polish the paint level , then use exquisite sand paper to polish the metal level to make it shine & smooth. 114 +))) 103 103 116 +[[image:image-20230613143052-5.png]] 104 104 105 -== 1.6 Button & LEDs == 106 106 119 +No polish needed if the container is shine metal surface without paint or non-metal container. 107 107 108 -[[image: Main.User Manual for LoRaWAN End Nodes.D20-LBD22-LBD23-LB_LoRaWAN_Temperature_Sensor_User_Manual.WebHome@1675071855856-879.png]]121 +[[image:image-20230613143125-6.png]] 109 109 110 110 111 -(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %) 112 -|=(% style="width: 167px;background-color:#D9E2F3;color:#0070C0" %)**Behavior on ACT**|=(% style="width: 117px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 225px;background-color:#D9E2F3;color:#0070C0" %)**Action** 113 -|(% style="width:167px" %)Pressing ACT between 1s < time < 3s|(% style="width:117px" %)Send an uplink|(% style="width:225px" %)((( 114 -If sensor is already Joined to LoRaWAN network, sensor will send an uplink packet, (% style="color:blue" %)**blue led** (%%)will blink once. 115 -Meanwhile, BLE module will be active and user can connect via BLE to configure device. 124 +((( 125 +(% style="color:blue" %)**Step3: **(%%)Test the installation point. 116 116 ))) 117 -|(% style="width:167px" %)Pressing ACT for more than 3s|(% style="width:117px" %)Active Device|(% style="width:225px" %)((( 118 -(% style="color:green" %)**Green led**(%%) will fast blink 5 times, device will enter (% style="color:#037691" %)**OTA mode**(%%) for 3 seconds. And then start to JOIN LoRaWAN network. 119 -(% style="color:green" %)**Green led**(%%) will solidly turn on for 5 seconds after joined in network. 120 -Once sensor is active, BLE module will be active and user can connect via BLE to configure device, no matter if device join or not join LoRaWAN network. 127 + 128 +((( 129 +Power on DDS20-LB, check if the blue LED is on, If the blue LED is on, means the sensor works. Then put ultrasonic coupling paste on the sensor and put it tightly on the installation point. 121 121 ))) 122 -|(% style="width:167px" %)Fast press ACT 5 times.|(% style="width:117px" %)Deactivate Device|(% style="width:225px" %)(% style="color:red" %)**Red led**(%%) will solid on for 5 seconds. Means device is in Deep Sleep Mode. 123 123 132 +((( 133 +It is necessary to put the coupling paste between the sensor and the container, otherwise DDS20-LB won't detect the liquid level. 134 +))) 124 124 136 +((( 137 +After paste the DDS20-LB well, power on DDS20-LB. In the first 30 seconds of booting, device will check the sensors status and BLUE LED will show the status as below. After 30 seconds, BLUE LED will be off to save battery life. 138 +))) 125 125 126 -== 1.7 BLE connection == 127 127 141 +((( 142 +(% style="color:red" %)**LED Status:** 143 +))) 128 128 129 -CPL03-LB support BLE remote configure. 145 +* ((( 146 +Onboard LED: When power on device, the onboard LED will fast blink 4 times which means detect the sensor well. 147 +))) 130 130 149 +* ((( 150 +(% style="color:blue" %)**BLUE LED**(% style="color:red" %)** always ON**(%%): Sensor is power on but doesn't detect liquid. There is problem in installation point. 151 +))) 152 +* ((( 153 +(% style="color:blue" %)**BLUE LED**(% style="color:red" %)** slowly blinking**(%%): Sensor detects Liquid Level, The installation point is good. 154 +))) 131 131 132 -BLE can be used to configure the parameter of sensor or see the console output from sensor. BLE will be only activate on below case: 156 +((( 157 +LDDS20 will enter into low power mode at 30 seconds after system reset or power on, Blue LED will be off after that. 158 +))) 133 133 134 -* Press button to send an uplink 135 -* Press button to active device. 136 -* Device Power on or reset. 137 137 138 -If there is no activity connection on BLE in 60 seconds, sensor will shut down BLE module to enter low power mode. 161 +((( 162 +(% style="color:red" %)**Note 2:** 163 +))) 139 139 165 +((( 166 +(% style="color:red" %)**Ultrasonic coupling paste** (%%) is subjected in most shipping way. So the default package doesn't include it and user needs to purchase locally. 167 +))) 140 140 141 -== 1.8 Pin Definitions == 142 142 143 -[[image:image-20230523174230-1.png]] 170 +((( 171 +(% style="color:blue" %)**Step4: **(%%)Install use Epoxy ab glue. 172 +))) 144 144 174 +((( 175 +Prepare Eproxy AB glue. 176 +))) 145 145 146 -== 1.9 Mechanical == 178 +((( 179 +Put Eproxy AB glue in the sensor and press it hard on the container installation point. 180 +))) 147 147 182 +((( 183 +Reset DDS20-LB and see if the BLUE LED is slowly blinking. 184 +))) 148 148 149 -[[image: Main.User.D20-LBD22-LBD23-LB_LoRaWAN_Temperature_Sensor_User_Manual.WebHome@1675143884058-338.png]]186 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDDS20%20-%20LoRaWAN%20Liquid%20Level%20Sensor%20User%20Manual/WebHome/image-20220615091045-8.png?width=341&height=203&rev=1.1||alt="image-20220615091045-8.png"]] [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDDS20%20-%20LoRaWAN%20Liquid%20Level%20Sensor%20User%20Manual/WebHome/image-20220615091045-9.png?width=284&height=200&rev=1.1||alt="image-20220615091045-9.png"]] 150 150 151 151 152 -[[image:Main.User Manual for LoRaWAN End Nodes.D20-LBD22-LBD23-LB_LoRaWAN_Temperature_Sensor_User_Manual.WebHome@1675143899218-599.png]] 189 +((( 190 +(% style="color:red" %)**Note 1:**(%%)** (% style="color:blue" %)Eproxy AB glue(%%)** needs 3~~ 5 minutes to stable attached. we can use other glue material to keep it in the position. 191 +))) 153 153 193 +((( 194 +(% style="color:red" %)**Note 2:**(%%)** (% style="color:blue" %)Eproxy AB glue(%%)** is subjected in most shipping way. So the default package doesn't include it and user needs to purchase locally. 195 +))) 154 154 155 -[[image:Main.User Manual for LoRaWAN End Nodes.D20-LBD22-LBD23-LB_LoRaWAN_Temperature_Sensor_User_Manual.WebHome@1675143909447-639.png]] 156 156 198 +== 1.6 Applications == 157 157 158 -= 2. Configure CPL03-LB to connect to LoRaWAN network = 159 159 160 - ==2.1Howitworks==201 +* Smart liquid control solution. 161 161 203 +* Smart liquefied gas solution. 162 162 163 - The CPL03-LB is configured as (% style="color:#037691"%)**LoRaWAN OTAA Class A**(%%) mode by default.It has OTAA keys to join LoRaWAN network. To connectalocal LoRaWAN network, youneedtoinput the OTAA keys in the LoRaWAN IoT server and pressthe button to activate the CPL03-LB. It will automatically join the network via OTAA and start to send the sensor value. The default uplink interval is 20 minutes.205 +== 1.7 Precautions == 164 164 165 -(% style="display:none" %) (%%) 166 166 167 - ==2.2Quickguide toconnecttoLoRaWANserver(OTAA)==208 +* At room temperature, containers of different materials, such as steel, glass, iron, ceramics, non-foamed plastics and other dense materials, have different detection blind areas and detection limit heights. 168 168 210 +* For containers of the same material at room temperature, the detection blind zone and detection limit height are also different for the thickness of the container. 169 169 170 - Followingisanexampleforhowto jointhe[[TTNv3LoRaWANNetwork>>url:https://console.cloud.thethings.network/]].Belowisthenetworkstructure;weusethe[[LPS8v2>>url:https://www.dragino.com/products/lora-lorawan-gateway/item/228-lps8v2.html]]as aLoRaWAN gatewayn thisexample.212 +* When the detected liquid level exceeds the effective detection value of the sensor, and the liquid level of the liquid to be measured shakes or tilts, the detected liquid height is unstable.(% style="display:none" %) 171 171 172 - TheLPS8v2is already settoconnectedto [[TTN network>>url:https://console.cloud.thethings.network/]],sowhat we needto now is configurethe TTN server.214 +== 1.8 Sleep mode and working mode == 173 173 174 -[[image:image-20230530111412-4.png||height="398" width="805"]](% style="display:none" %) 175 175 217 +(% style="color:blue" %)**Deep Sleep Mode: **(%%)Sensor doesn't have any LoRaWAN activate. This mode is used for storage and shipping to save battery life. 176 176 177 -(% style="color:blue" %)** Step1:**(%%)Create a device inTTNwith theOTAA keysfromCPL03-LB.219 +(% style="color:blue" %)**Working Mode:** (%%)In this mode, Sensor will work as LoRaWAN Sensor to Join LoRaWAN network and send out sensor data to server. Between each sampling/tx/rx periodically, sensor will be in IDLE mode), in IDLE mode, sensor has the same power consumption as Deep Sleep mode. 178 178 179 -Each CPL03-LB is shipped with a sticker with the default device EUI as below: 180 180 181 - [[image:image-20230426084152-1.png||alt="图片-20230426084152-1.png"height="233" width="502"]]222 +== 1.9 Button & LEDs == 182 182 183 183 184 - You canenterthiskeyintheServerportal.Below is TTN screenshot:225 +[[image:Main.User Manual for LoRaWAN End Nodes.D20-LBD22-LBD23-LB_LoRaWAN_Temperature_Sensor_User_Manual.WebHome@1675071855856-879.png]] 185 185 186 186 187 -(% style="color:blue" %)**Register the device** 188 - 189 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LSN50v2-S31-S31B%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20User%20Manual/WebHome/1654935135620-998.png?rev=1.1||alt="1654935135620-998.png"]] 190 - 191 - 192 -(% style="color:blue" %)**Add APP EUI and DEV EUI** 193 - 194 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LSN50v2-S31-S31B%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20User%20Manual/WebHome/image-20220611161308-4.png?width=753&height=551&rev=1.1||alt="图片-20220611161308-4.png"]] 195 - 196 - 197 -(% style="color:blue" %)**Add APP EUI in the application** 198 - 199 - 200 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LSN50v2-S31-S31B%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20User%20Manual/WebHome/image-20220611161308-5.png?width=742&height=601&rev=1.1||alt="图片-20220611161308-5.png"]] 201 - 202 - 203 -(% style="color:blue" %)**Add APP KEY** 204 - 205 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LSN50v2-S31-S31B%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20User%20Manual/WebHome/image-20220611161308-6.png?width=744&height=485&rev=1.1||alt="图片-20220611161308-6.png"]] 206 - 207 - 208 -(% style="color:blue" %)**Step 2:**(%%) Activate on CPL03-LB 209 - 210 - 211 -Press the button for 5 seconds to activate the CPL03-LB. 212 - 213 -(% style="color:green" %)**Green led**(%%) will fast blink 5 times, device will enter (% style="color:blue" %)**OTA mode**(%%) for 3 seconds. And then start to JOIN LoRaWAN network. (% style="color:green" %)**Green led**(%%) will solidly turn on for 5 seconds after joined in network. 214 - 215 -After join success, it will start to upload messages to TTN and you can see the messages in the panel. 216 - 217 - 218 -== 2.3 Uplink Payload == 219 - 220 -=== 2.3.1 Device Status, FPORT~=5 === 221 - 222 - 223 -Users can use the downlink command(**0x26 01**) to ask CPL03-LB to send device configure detail, include device configure status. CPL03-LB will uplink a payload via FPort=5 to server. 224 - 225 -The Payload format is as below. 226 - 227 - 228 228 (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %) 229 -|(% colspan="6" style="background-color:#d9e2f3; color:#0070c0" %)**Device Status (FPORT=5)** 230 -|(% style="width:103px" %)**Size (bytes)**|(% style="width:72px" %)**1**|**2**|(% style="width:91px" %)**1**|(% style="width:86px" %)**1**|(% style="width:44px" %)**2** 231 -|(% style="width:103px" %)**Value**|(% style="width:72px" %)Sensor Model|Firmware Version|(% style="width:91px" %)Frequency Band|(% style="width:86px" %)Sub-band|(% style="width:44px" %)BAT 229 +|=(% style="width: 167px;background-color:#D9E2F3;color:#0070C0" %)**Behavior on ACT**|=(% style="width: 117px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 225px;background-color:#D9E2F3;color:#0070C0" %)**Action** 230 +|(% style="width:167px" %)Pressing ACT between 1s < time < 3s|(% style="width:117px" %)Send an uplink|(% style="width:225px" %)((( 231 +If sensor is already Joined to LoRaWAN network, sensor will send an uplink packet, (% style="color:blue" %)**blue led** (%%)will blink once. 232 +Meanwhile, BLE module will be active and user can connect via BLE to configure device. 233 +))) 234 +|(% style="width:167px" %)Pressing ACT for more than 3s|(% style="width:117px" %)Active Device|(% style="width:225px" %)((( 235 +(% style="color:green" %)**Green led**(%%) will fast blink 5 times, device will enter (% style="color:#037691" %)**OTA mode**(%%) for 3 seconds. And then start to JOIN LoRaWAN network. 236 +(% style="color:green" %)**Green led**(%%) will solidly turn on for 5 seconds after joined in network. 237 +Once sensor is active, BLE module will be active and user can connect via BLE to configure device, no matter if device join or not join LoRaWAN network. 238 +))) 239 +|(% style="width:167px" %)Fast press ACT 5 times.|(% style="width:117px" %)Deactivate Device|(% style="width:225px" %)(% style="color:red" %)**Red led**(%%) will solid on for 5 seconds. Means device is in Deep Sleep Mode. 232 232 233 -E xampleparseTTNv3241 +== 1.10 BLE connection == 234 234 235 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/CPL01%20LoRaWAN%20Outdoor%20PulseContact%20%20Sensor%20Manual/WebHome/1652859749264-179.png?width=723&height=275&rev=1.1||alt="1652859749264-179.png"]] 236 236 244 +DDS20-LB support BLE remote configure. 237 237 238 - (%style="color:#037691"%)**SensorModel**(%%):ForCPL03-LB,thisvalueis0x0A246 +BLE can be used to configure the parameter of sensor or see the console output from sensor. BLE will be only activate on below case: 239 239 240 -(% style="color:#037691" %)**Firmware Version**(%%): 0x0100, Means: v1.0.0 version 248 +* Press button to send an uplink 249 +* Press button to active device. 250 +* Device Power on or reset. 241 241 242 - (%style="color:#037691"%)**FrequencyBand**:252 +If there is no activity connection on BLE in 60 seconds, sensor will shut down BLE module to enter low power mode. 243 243 244 -*0x01: EU868 245 245 246 - *0x02:US915255 +== 1.11 Pin Definitions == 247 247 248 - *0x03: IN865257 +[[image:image-20230523174230-1.png]] 249 249 250 -*0x04: AU915 251 251 252 - *0x05:KZ865260 +== 1.12 Mechanical == 253 253 254 -*0x06: RU864 255 255 256 - *0x07: AS923263 +[[image:Main.User Manual for LoRaWAN End Nodes.D20-LBD22-LBD23-LB_LoRaWAN_Temperature_Sensor_User_Manual.WebHome@1675143884058-338.png]] 257 257 258 -*0x08: AS923-1 259 259 260 - *0x09: AS923-2266 +[[image:Main.User Manual for LoRaWAN End Nodes.D20-LBD22-LBD23-LB_LoRaWAN_Temperature_Sensor_User_Manual.WebHome@1675143899218-599.png]] 261 261 262 -*0x0a: AS923-3 263 263 264 - *0x0b:CN470269 +[[image:Main.User Manual for LoRaWAN End Nodes.D20-LBD22-LBD23-LB_LoRaWAN_Temperature_Sensor_User_Manual.WebHome@1675143909447-639.png]] 265 265 266 -*0x0c: EU433 267 267 268 - *0x0d:KR920272 +(% style="color:blue" %)**Probe Mechanical:** 269 269 270 - *0x0e:869274 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDDS20%20-%20LoRaWAN%20Liquid%20Level%20Sensor%20User%20Manual/WebHome/image-20220615090910-1.png?rev=1.1||alt="image-20220615090910-1.png"]] 271 271 272 272 273 - (% style="color:#037691"%)**Sub-Band**:277 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDDS20%20-%20LoRaWAN%20Liquid%20Level%20Sensor%20User%20Manual/WebHome/image-20220615090910-2.png?rev=1.1||alt="image-20220615090910-2.png"]] 274 274 275 -AU915 and US915:value 0x00 ~~ 0x08 276 276 277 - CN470:value 0x0B~~0x0C280 += 2. Configure DDS20-LB to connect to LoRaWAN network = 278 278 279 - OtherBands:Always0x00282 +== 2.1 How it works == 280 280 281 281 282 -(% style="color:#037691" %)** Battery Info**:285 +The DDS20-LB is configured as (% style="color:#037691" %)**LoRaWAN OTAA Class A**(%%) mode by default. It has OTAA keys to join LoRaWAN network. To connect a local LoRaWAN network, you need to input the OTAA keys in the LoRaWAN IoT server and press the button to activate the DDS20-LB. It will automatically join the network via OTAA and start to send the sensor value. The default uplink interval is 20 minutes. 283 283 284 - Checkthebatteryvoltage.287 +(% style="display:none" %) (%%) 285 285 286 - Ex1: 0x0B45= 2885mV289 +== 2.2 Quick guide to connect to LoRaWAN server (OTAA) == 287 287 288 -Ex2: 0x0B49 = 2889mV 289 289 292 +Following is an example for how to join the [[TTN v3 LoRaWAN Network>>url:https://console.cloud.thethings.network/]]. Below is the network structure; we use the [[LPS8v2>>url:https://www.dragino.com/products/lora-lorawan-gateway/item/228-lps8v2.html]] as a LoRaWAN gateway in this example. 290 290 291 - ===2.3.2SensorConfiguration,FPORT~=4===294 +The LPS8v2 is already set to connected to [[TTN network >>url:https://console.cloud.thethings.network/]], so what we need to now is configure the TTN server. 292 292 296 +[[image:image-20230613140140-4.png||height="453" width="800"]](% style="display:none" %) 293 293 294 -CPL03-LB will only send this command after getting the downlink command (0x26 02) from the server. 295 295 296 -(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %) 297 -|(% colspan="6" style="background-color:#d9e2f3; color:#0070c0; width:504px" %)**Sensor Configuration FPORT=4** 298 -|**Size(bytes)**|(% style="width:75px" %)**3**|(% style="width:77px" %)**1**|(% style="width:96px" %)**1**|(% style="width:158px" %)**2**|(% style="width:158px" %)**1** 299 -|**Value**|(% style="width:75px" %)TDC (unit:sec)|(% style="width:77px" %)Disalarm|(% style="width:96px" %)Keep status|(% style="width:158px" %)Keep time (unit: sec)|(% style="width:158px" %)Trigger mode 299 +(% style="color:blue" %)**Step 1:**(%%) Create a device in TTN with the OTAA keys from DDS20-LB. 300 300 301 -* ((( 302 -(% style="color:#037691" %)** TDC: (default: 0x001C20)** 303 -))) 301 +Each DDS20-LB is shipped with a sticker with the default device EUI as below: 304 304 305 -((( 306 -Uplink interval for the total pulse count, default value is 0x001C20 which is 7200 seconds = 2 hours. 303 +[[image:image-20230426084152-1.png||alt="图片-20230426084152-1.png" height="233" width="502"]] 307 307 308 - 309 -))) 310 310 311 -* ((( 312 -(% style="color:#037691" %)** Disalarm: (default: 0)** 313 -))) 306 +You can enter this key in the LoRaWAN Server portal. Below is TTN screen shot: 314 314 315 -((( 316 -(% style="color:blue" %)** If Disalarm = 1**(%%), CPL03-LB will only send uplink at every TDC periodically. This is normally use for pulse meter application, in this application, there are many disconnect/connect event, and platform only care about the total number of pulse. 317 -))) 318 318 319 -((( 320 -(% style="color:blue" %)** If Disalarm = 0**(%%), CPL03-LB will send uplink at every TDC periodically. 309 +(% style="color:blue" %)**Register the device** 321 321 322 - 323 -))) 311 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LSN50v2-S31-S31B%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20User%20Manual/WebHome/1654935135620-998.png?rev=1.1||alt="1654935135620-998.png"]] 324 324 325 -* ((( 326 -(% style="color:#037691" %)** Keep Status & Keep Time** 327 -))) 328 328 329 -((( 330 -Shows the configure value of [[Alarm Base on Timeout Feature>>||anchor="H3.3.5AlarmBaseonTimeout"]] 314 +(% style="color:blue" %)**Add APP EUI and DEV EUI** 331 331 332 - 333 -))) 316 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LSN50v2-S31-S31B%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20User%20Manual/WebHome/image-20220611161308-4.png?width=753&height=551&rev=1.1||alt="图片-20220611161308-4.png"]] 334 334 335 -* ((( 336 -(% style="color:#037691" %)** Trigger mode (default: 0)** 337 -))) 338 338 339 -((( 340 -(% style="color:blue" %)** If Trigger mode = 0**(%%), count close to open event. 341 -))) 319 +(% style="color:blue" %)**Add APP EUI in the application** 342 342 343 -((( 344 -(% style="color:blue" %)** If Trigger mode = 1**(%%), count open to close event. 345 -))) 346 346 347 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/ CPL01%20LoRaWAN%20Outdoor%20PulseContact%20%20Sensor%20Manual/WebHome/1652860064987-743.png?width=730&height=152&rev=1.1||alt="1652860064987-743.png"]]322 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LSN50v2-S31-S31B%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20User%20Manual/WebHome/image-20220611161308-5.png?width=742&height=601&rev=1.1||alt="图片-20220611161308-5.png"]] 348 348 349 349 350 - [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/CPL01%20LoRaWAN%20Outdoor%20PulseContact%20%20Sensor%20Manual/WebHome/1652860079526-831.png?width=729&height=209&rev=1.1||alt="1652860079526-831.png"]]325 +(% style="color:blue" %)**Add APP KEY** 351 351 327 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LSN50v2-S31-S31B%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20User%20Manual/WebHome/image-20220611161308-6.png?width=744&height=485&rev=1.1||alt="图片-20220611161308-6.png"]] 352 352 353 -=== 2.3.3 Real-Time Open/Close Status, Uplink FPORT~=2 === 354 354 330 +(% style="color:blue" %)**Step 2:**(%%) Activate on DDS20-LB 355 355 356 -((( 357 -((( 358 -CPL03-LB will send this uplink **after** Device Status once join the LoRaWAN network successfully. And CPL03-LB will: 359 -))) 360 -))) 361 361 362 -((( 363 -((( 364 -periodically send this uplink every 2 hours, this interval [[can be changed>>||anchor="H3.3.1SetTransmitIntervalTime"]]. 365 -))) 366 -))) 333 +Press the button for 5 seconds to activate the DDS20-LB. 367 367 368 -((( 369 -((( 370 -Uplink Payload totals 11 bytes. 371 -))) 372 -))) 335 +(% style="color:green" %)**Green led**(%%) will fast blink 5 times, device will enter (% style="color:blue" %)**OTA mode**(%%) for 3 seconds. And then start to JOIN LoRaWAN network. (% style="color:green" %)**Green led**(%%) will solidly turn on for 5 seconds after joined in network. 373 373 374 -(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:520px" %) 375 -|=(% colspan="5" style="background-color:#D9E2F3;color:#0070C0; width: 520px;" %)**Real-Time Open/Close Status, FPORT=2** 376 -|(% style="width:60px" %)**Size(bytes)**|(% style="width:65px" %)**1**|(% style="width:65px" %)**3**|(% style="width:240px" %)**3**|(% style="width:90px" %)**4** 377 -|(% style="width:101px" %)**Value**|(% style="width:133px" %)Status & [[Alarm>>||anchor="H3.3.5AlarmBaseonTimeout"]]|(% style="width:92px" %)Total pulse|(% style="width:247px" %)The last open duration (unit: min)|(% style="width:149px" %)[[Unix TimeStamp>>||anchor="H2.5.2UnixTimeStamp"]] 337 +After join success, it will start to upload messages to TTN and you can see the messages in the panel. 378 378 379 -(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:504px" %) 380 -|=(% colspan="4" style="background-color:#D9E2F3;color:#0070C0; width: 502px;" %)**Status & Alarm field** 381 -|(% style="width:60px" %)**Size(bit)**|(% style="width:70px" %)**6**|(% style="width:228px" %)**1**|(% style="width:146px" %)**1** 382 -|(% style="width:76px" %)Value|(% style="width:80px" %)Calculate Flag|(% style="width:208px" %)Alarm: 0: No Alarm; 1: Alarm|(% style="width:136px" %)Contact Status: 0: Open, 1: Close 383 383 384 -* ((( 385 -(% style="color:#037691" %)** Calculate Flag** 386 -))) 340 +== 2.3 Uplink Payload == 387 387 388 -((( 389 -The calculate flag is a user define field, IoT server can use this filed to handle different meter with different pulse factor. For example, if there are 100 water meters, meter 1 ~~50 are 1 liter/pulse and meter 51 ~~ 100 has 1.5 liter/pulse. 390 -))) 391 391 392 392 ((( 393 - Usercan set calculateflagto1 for meter 1~~50and2 for meter 51 ~~ 100, So IoT Servercanusethisfield forcalculation.344 +DDS20-LB will uplink payload via LoRaWAN with below payload format: 394 394 ))) 395 395 396 396 ((( 397 - Defaultvalue:0.348 +Uplink payload includes in total 8 bytes. 398 398 ))) 399 399 400 -((( 401 -Range (6 bits): (b)000000 ~~ (b) 111111 402 -))) 351 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:510px" %) 352 +|=(% style="width: 62.5px;background-color:#D9E2F3;color:#0070C0" %)((( 353 +**Size(bytes)** 354 +)))|=(% style="width: 62.5px;background-color:#D9E2F3;color:#0070C0" %)**2**|=(% style="background-color:#D9E2F3;color:#0070C0" %)**2**|=(% style="background-color:#D9E2F3;color:#0070C0" %)1|=(% style="background-color:#D9E2F3;color:#0070C0" %)2|=(% style="background-color:#D9E2F3;color:#0070C0" %)**1** 355 +|(% style="width:62.5px" %)**Value**|(% style="width:62.5px" %)[[BAT>>||anchor="H2.3.1A0BatteryInfo"]]|((( 356 +[[Distance>>||anchor="H2.3.2A0Distance"]] 357 +(unit: mm) 358 +)))|[[Digital Interrupt (Optional)>>||anchor="H2.3.3A0InterruptPin"]]|((( 359 +[[Temperature (Optional )>>||anchor="H2.3.4A0DS18B20Temperaturesensor"]] 360 +)))|[[Sensor Flag>>||anchor="H2.3.5A0SensorFlag"]] 403 403 404 -((( 405 -Refer: [[Set Calculate Flag>>||anchor="H3.3.8Setthecalculateflag"]] 362 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDDS20%20-%20LoRaWAN%20Liquid%20Level%20Sensor%20User%20Manual/WebHome/1654850511545-399.png?rev=1.1||alt="1654850511545-399.png"]] 406 406 407 - 408 -))) 409 409 410 -* ((( 411 -(% style="color:#037691" %)** Alarm** 412 -))) 365 +=== 2.3.1 Battery Info === 413 413 414 -((( 415 -See [[Alarm Base on Timeout>>||anchor="H3.3.5AlarmBaseonTimeout"]] 416 416 417 - 418 -))) 368 +Check the battery voltage for DDS20-LB. 419 419 420 -* ((( 421 -(% style="color:#037691" %)** Contact Status** 422 -))) 370 +Ex1: 0x0B45 = 2885mV 423 423 424 -((( 425 -0: Open 426 -))) 372 +Ex2: 0x0B49 = 2889mV 427 427 428 -((( 429 -1: Close 430 430 431 - 432 -))) 375 +=== 2.3.2 Distance === 433 433 434 -* ((( 435 -(% style="color:#037691" %)** Total pulse** 436 -))) 437 437 438 438 ((( 439 - Total pulse/countingbaseondry [[contacttriggerevent>>||anchor="H2.3.2SensorConfiguration2CFPORT3D4"]]379 +Get the distance. Flat object range 20mm - 2000mm. 440 440 ))) 441 441 442 442 ((( 443 - Range(3Bytes):0x000000~~0xFFFFFF.Max:16777215383 +For example, if the data you get from the register is **0x06 0x05**, the distance between the sensor and the measured object is(% style="color:#4472c4" %)** ** 444 444 445 - 385 +(% style="color:blue" %)**0605(H) = 1541 (D) = 1541 mm.** 446 446 ))) 447 447 448 -* ((( 449 -(% style="color:#037691" %)** The last open duration** 450 -))) 388 +* If the sensor value is 0x0000, it means system doesn't detect ultrasonic sensor. 451 451 452 -((( 453 -Dry Contact last open duration. 454 -))) 390 +* If the sensor value lower than 0x0014 (20mm), the sensor value will be invalid. 455 455 456 -((( 457 -Unit: min. 458 -))) 392 +=== 2.3.3 Interrupt Pin === 459 459 460 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/CPL01%20LoRaWAN%20Outdoor%20PulseContact%20%20Sensor%20Manual/WebHome/1652860403792-491.png?width=735&height=153&rev=1.1||alt="1652860403792-491.png"]] 461 461 395 +This data field shows if this packet is generated by interrupt or not. [[Click here>>||anchor="H3.3.2SetInterruptMode"]] for the hardware and software set up. 462 462 463 - === 2.3.4 Real-Time Open/CloseStatus, 3 pulse mode, Uplink FPORT~=6 ===397 +**Example:** 464 464 399 +0x00: Normal uplink packet. 465 465 466 - (%style="color:red" %)**Note:**401 +0x01: Interrupt Uplink Packet. 467 467 468 -* Firmware support for this mode is not released. If users want to test, please contact Dragino support. 469 -* Users need to run (% style="color:blue" %)**AT+MOD=3**(%%) to support this model after updating the firmware. 470 -* This mode doesn't support Historical Events and Datalog features. 471 471 472 - (% style="color:blue"%)**CPL03-LB3 PulseWiring:**404 +=== 2.3.4 DS18B20 Temperature sensor === 473 473 474 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/CPL01%20LoRaWAN%20Outdoor%20PulseContact%20%20Sensor%20Manual/WebHome/image-20221013153352-1.png?width=720&height=628&rev=1.1||alt="image-20221013153352-1.png"]] 475 475 407 +This is optional, user can connect external DS18B20 sensor to the +3.3v, 1-wire and GND pin . and this field will report temperature. 476 476 477 - (% style="color:blue" %)**Payload:**409 +**Example**: 478 478 479 - [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/CPL01%20LoRaWAN%20Outdoor%20PulseContact%20%20Sensor%20Manual/WebHome/image-20221013153352-2.png?width=1215&height=167&rev=1.1||alt="image-20221013153352-2.png"]]411 +If payload is: 0105H: (0105 & FC00 == 0), temp = 0105H /10 = 26.1 degree 480 480 413 +If payload is: FF3FH : (FF3F & FC00 == 1) , temp = (FF3FH - 65536)/10 = -19.3 degrees. 481 481 482 -(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:447px" %) 483 -|(% style="background-color:#d9e2f3; color:#0070c0; width:95px" %)**Size(bytes)**|(% style="background-color:#d9e2f3; color:#0070c0; width:61px" %)**1**|(% style="background-color:#d9e2f3; color:#0070c0; width:98px" %)**3**|(% style="background-color:#d9e2f3; color:#0070c0; width:98px" %)**3**|(% style="background-color:#d9e2f3; color:#0070c0; width:95px" %)**3** 484 -|(% style="width:93px" %)Value|(% style="width:59px" %)Status|(% style="width:98px" %)((( 485 -Port1 Total Pulse(PB14) 486 -)))|(% style="width:96px" %)((( 487 -Port2 Total Pulse(PB15) 488 -)))|(% style="width:94px" %)((( 489 -Port3 Total Pulse(PA4) 490 -))) 491 491 492 - (%style="color:blue"%)**Status:**416 +=== 2.3.5 Sensor Flag === 493 493 494 -(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:257px" %) 495 -|(% style="background-color:#d9e2f3; color:#0070c0; width:75px" %)**Size(bit)**|(% style="background-color:#d9e2f3; color:#0070c0; width:112px" %)**6**|(% style="background-color:#d9e2f3; color:#0070c0; width:70px" %)**2** 496 -|(% style="width:75px" %)Value|(% style="width:111px" %)Calculate Flag|(% style="width:68px" %)Reserve 497 497 498 -(% style="color:red" %)**Max COUNT for each port is 16777215. Exceed this number will reset to 1.** 499 - 500 - 501 -(% style="color:blue" %)**Related AT Command:** 502 - 503 -(% style="color:#037691" %)**AT+TTRMOD1: Port1 count mode; 0: Signal falling edge(Default), 1: Signal raising edge** 504 - 505 - AT+TTRMOD1=0 Downlink Command: 0xA4 01 00 506 - 507 - AT+TTRMOD1=1 Downlink Command: 0xA4 01 01 508 - 509 - 510 -(% style="color:#037691" %)**AT+TTRMOD2: Port2 count mode; 0: Signal falling edge(Default), 1: Signal raising edge** 511 - 512 - AT+TTRMOD1=0 Downlink Command: 0xA4 02 00 513 - 514 - AT+TTRMOD1=1 Downlink Command: 0xA4 02 01 515 - 516 - 517 -(% style="color:#037691" %)**AT+TTRMOD3: Port3 count mode; 0: Signal falling edge(Default), 1: Signal raising edge** 518 - 519 - AT+TTRMOD1=0 Downlink Command: 0xA4 03 00 520 - 521 - AT+TTRMOD1=1 Downlink Command: 0xA4 03 01 522 - 523 - 524 -(% style="color:#037691" %)**AT+CALCFLAG: Calculate Flag ( Default : 0 )** 525 - 526 - AT+CALCFLAG=aa 527 - 528 - 529 -(% style="color:blue" %)**Downlink Command: 0xA5 aa** 530 - 531 -(% style="color:#037691" %)**AT+COUNTMOD: Accumulative Mode; 0: Accumulative (Default),1: Reset after uplink.** 532 - 533 - AT+COUNTMOD=0 Downlink Command: 0x0B 00 534 - 535 - AT+COUNTMOD=1 Downlink Command: 0x0B 01 536 - 537 - 538 -(% style="color:#037691" %)**AT+SETCNT: Set count value** 539 - 540 - AT+SETCNT=1,aa Downlink Command: 0xA6 01 aa aa aa 541 - 542 - AT+SETCNT=2,aa Downlink Command: 0xA6 02 aa aa aa 543 - 544 - AT+SETCNT=3,aa Downlink Command: 0xA6 03 aa aa aa 545 - 546 - 547 -(% style="color:blue" %)**Decode: **(%%)[[https:~~/~~/github.com/dragino/dragino-end-node-decoder>>https://github.com/dragino/dragino-end-node-decoder]] 548 - 549 - 550 -=== 2.3.5 Historical Door Open/Close Event, FPORT~=3 === 551 - 552 - 553 553 ((( 554 - CPL03-LBstores sensor values and userscan retrievethese history valuesvia the [[downlinkcommand>>||anchor="H2.5DatalogFeature"]].420 +0x01: Detect Ultrasonic Sensor 555 555 ))) 556 556 557 557 ((( 558 - Thehistoricalpayload includes one or multiplies entriesand every entry hasthe same payload as Real-Timeopen/close status.424 +0x00: No Ultrasonic Sensor 559 559 ))) 560 560 561 -* ((( 562 -Each data entry is 11 bytes and has the same structure as [[Real-Time open/close status>>||anchor="H2.3.3Real-TimeOpen2FCloseStatus2CUplinkFPORT3D2"]], to save airtime and battery, CPL03-LB will send max bytes according to the current DR and Frequency bands. 563 -))) 564 564 565 -((( 566 -For example, in the US915 band, the max payload for different DR is: 567 -))) 428 +=== 2.3.6 Decode payload in The Things Network === 568 568 569 -((( 570 -a) (% style="color:blue" %)**DR0**(%%): max is 11 bytes so one entry of data 571 -))) 572 572 573 -((( 574 -b) (% style="color:blue" %)**DR1**(%%): max is 53 bytes so devices will upload 4 entries of data (total 44 bytes) 575 -))) 431 +While using TTN network, you can add the payload format to decode the payload. 576 576 577 -((( 578 -c) (% style="color:blue" %)**DR2**(%%): total payload includes 11 entries of data 579 -))) 433 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDDS75%20-%20LoRaWAN%20Distance%20Detection%20Sensor%20User%20Manual/WebHome/1654850829385-439.png?rev=1.1||alt="1654850829385-439.png"]] 580 580 581 -((( 582 -d) (% style="color:blue" %)**DR3**(%%): total payload includes 22 entries of data. 583 -))) 435 +The payload decoder function for TTN V3 is here: 584 584 585 585 ((( 586 -If CPL03-LB doesn't have any data in the polling time. It will uplink 11 bytes of 0 587 - 588 - 438 +DDS20-LB TTN V3 Payload Decoder: [[ttps:~~/~~/github.com/dragino/dragino-end-node-decoder>>https://github.com/dragino/dragino-end-node-decoder]] 589 589 ))) 590 590 591 -(% style="color:blue" %)** Downlink:** 592 592 593 -(% class="box" %) 594 -((( 595 -**0x31 61 E9 3A D4 61 E9 3D E0 05** 596 -))) 442 +== 2.4 Uplink Interval == 597 597 598 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/CPL01%20LoRaWAN%20Outdoor%20PulseContact%20%20Sensor%20Manual/WebHome/1652861353248-624.png?width=720&height=189&rev=1.1||alt="1652861353248-624.png"]] 599 599 445 +The DDS20-LB by default uplink the sensor data every 20 minutes. User can change this interval by AT Command or LoRaWAN Downlink Command. See this link: [[Change Uplink Interval>>||anchor="H3.3.1SetTransmitIntervalTime"]] 600 600 601 -(% style="color:blue" %)** Uplink:** 602 602 603 -(% class="box" %) 604 -((( 605 -**0E 00 23 E6 00 00 00 61 E9 3B 04 0E 00 23 E6 00 00 00 61 E9 3B 25 0D 00 00 00 00 00 00 61 E9 3B C8 0E 00 00 02 00 00 00 61 E9 3B D4 0E 00 00 06 00 00 00 61 E9 3B DB 01 00 00 00 00 00 00 61 E9 3C 91 01 00 00 00 00 00 00 61 E9 3C A1 0D 00 00 00 00 00 00 61 E9 3C BC 0E 00 00 07 00 00 00 61 E9 3C D6 00 00 00 00 00 00 00 61 E9 3D A6** 606 -))) 448 +== 2.5 Show Data in DataCake IoT Server == 607 607 608 -(% style="color:#037691" %)** ** 609 609 610 -(% style="color:#037691" %)**Parsed Value:** 611 - 612 612 ((( 613 -[A LARM,PIN_STATUS, TOTAL_PULSE,CALCULATE_FLAG,LAST_OPEN_DURATION, TIME]452 +[[DATACAKE>>url:https://datacake.co/]] provides a human friendly interface to show the sensor data, once we have data in TTN, we can use [[DATACAKE>>url:https://datacake.co/]] to connect to TTN and see the data in DATACAKE. Below are the steps: 614 614 ))) 615 615 616 -((( 617 - 618 -))) 619 619 620 620 ((( 621 - [TRUE,CLOSE,9190,3,0,2022-01-2010:35:48],457 +(% style="color:blue" %)**Step 1**(%%)**: Be sure that your device is programmed and properly connected to the network at this time.** 622 622 ))) 623 623 624 624 ((( 625 - [TRUE,CLOSE,9190,3,0,2022-01-2010:36:21],461 +(% style="color:blue" %)**Step 2**(%%)**: To configure the Application to forward data to DATACAKE you will need to add integration. To add the DATACAKE integration, perform the following steps:** 626 626 ))) 627 627 628 -((( 629 -[FALSE, OPEN, 0, 3, 0, 2022-01-20 10:39:04], 630 -))) 631 631 632 -((( 633 -[TRUE, CLOSE, 2, 3, 0, 2022-01-20 10:39:16], 634 -))) 465 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDDS75%20-%20LoRaWAN%20Distance%20Detection%20Sensor%20User%20Manual/WebHome/1654592790040-760.png?rev=1.1||alt="1654592790040-760.png"]] 635 635 636 -((( 637 -[TRUE, CLOSE, 6, 3, 0, 2022-01-20 10:39:23], 638 -))) 639 639 640 -((( 641 -[FALSE, OPEN, 0, 0, 0, 2022-01-20 10:42:25], 642 -))) 468 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDDS75%20-%20LoRaWAN%20Distance%20Detection%20Sensor%20User%20Manual/WebHome/1654592800389-571.png?rev=1.1||alt="1654592800389-571.png"]] 643 643 644 -((( 645 -[FALSE, OPEN, 0, 0, 0, 2022-01-20 10:42:41], 646 -))) 647 647 648 -((( 649 -[FALSE, OPEN, 0, 3, 0, 2022-01-20 10:43:08], 650 -))) 471 +(% style="color:blue" %)**Step 3**(%%)**: Create an account or log in Datacake.** 651 651 652 -((( 653 -[TRUE, CLOSE, 7, 3, 0, 2022-01-20 10:43:34], 654 -))) 473 +(% style="color:blue" %)**Step 4**(%%)**: Search the DDS20-LB and add DevEUI.** 655 655 656 -((( 657 -[FALSE, CLOSE, 0, 0, 0, 2022-01-20 10:47:02], 475 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDDS75%20-%20LoRaWAN%20Distance%20Detection%20Sensor%20User%20Manual/WebHome/1654851029373-510.png?rev=1.1||alt="1654851029373-510.png"]] 658 658 659 - 660 -))) 661 661 662 - [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/CPL01%20LoRaWAN%20Outdoor%20PulseContact%20%20Sensor%20Manual/WebHome/1652861480446-216.png?rev=1.1||alt="1652861480446-216.png"]]478 +After added, the sensor data arrive TTN V3, it will also arrive and show in Datacake. 663 663 480 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDDS75%20-%20LoRaWAN%20Distance%20Detection%20Sensor%20User%20Manual/WebHome/image-20220610165129-11.png?width=1088&height=595&rev=1.1||alt="image-20220610165129-11.png"]] 664 664 665 -== 2.4 Payload Decoder file == 666 666 667 667 668 - InTTN,use can add a custom payloadso itshows friendlyreading484 +== 2.6 Datalog Feature == 669 669 670 -In the page (% style="color:#037691" %)**Applications ~-~-> Payload Formats ~-~-> Custom ~-~-> decoder**(%%) to add the decoder from: [[https:~~/~~/github.com/dragino/dragino-end-node-decoder>>https://github.com/dragino/dragino-end-node-decoder]] 671 671 487 +Datalog Feature is to ensure IoT Server can get all sampling data from Sensor even if the LoRaWAN network is down. For each sampling, DDS20-LB will store the reading for future retrieving purposes. 672 672 673 -== 2.5 Datalog Feature == 674 674 490 +=== 2.6.1 Ways to get datalog via LoRaWAN === 675 675 676 -Datalog Feature is to ensure IoT Server can get all sampling data from Sensor even if the LoRaWAN network is down. For each sampling, CPL03-LB will store the reading for future retrieving purposes. 677 677 493 +Set PNACKMD=1, DDS20-LB will wait for ACK for every uplink, when there is no LoRaWAN network,DDS20-LB will mark these records with non-ack messages and store the sensor data, and it will send all messages (10s interval) after the network recovery. 678 678 679 -=== 2.5.1 Ways to get datalog via LoRaWAN === 680 - 681 - 682 -Set PNACKMD=1, CPL03-LB will wait for ACK for every uplink, when there is no LoRaWAN network,CPL03-LB will mark these records with non-ack messages and store the sensor data, and it will send all messages (10s interval) after the network recovery. 683 - 684 684 * ((( 685 -a) CPL03-LB will do an ACK check for data records sending to make sure every data arrive server.496 +a) DDS20-LB will do an ACK check for data records sending to make sure every data arrive server. 686 686 ))) 687 687 * ((( 688 -b) CPL03-LB will send data in **CONFIRMED Mode** when PNACKMD=1, butCPL03-LB won't re-transmit the packet if it doesn't get ACK, it will just mark it as a NONE-ACK message. In a future uplink ifCPL03-LB gets a ACK,CPL03-LB will consider there is a network connection and resend all NONE-ACK messages.499 +b) DDS20-LB will send data in **CONFIRMED Mode** when PNACKMD=1, but DDS20-LB won't re-transmit the packet if it doesn't get ACK, it will just mark it as a NONE-ACK message. In a future uplink if DDS20-LB gets a ACK, DDS20-LB will consider there is a network connection and resend all NONE-ACK messages. 689 689 ))) 690 690 691 691 Below is the typical case for the auto-update datalog feature (Set PNACKMD=1) ... ... @@ -693,10 +693,10 @@ 693 693 [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/WebHome/image-20220703111700-2.png?width=1119&height=381&rev=1.1||alt="图片-20220703111700-2.png" height="381" width="1119"]] 694 694 695 695 696 -=== 2. 5.2 Unix TimeStamp ===507 +=== 2.6.2 Unix TimeStamp === 697 697 698 698 699 - CPL03-LB uses Unix TimeStamp format based on510 +DDS20-LB uses Unix TimeStamp format based on 700 700 701 701 [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/WebHome/image-20220523001219-11.png?width=627&height=97&rev=1.1||alt="图片-20220523001219-11.png" height="97" width="627"]] 702 702 ... ... @@ -710,17 +710,17 @@ 710 710 So, we can use AT+TIMESTAMP=1611889405 or downlink 3060137afd00 to set the current time 2021 – Jan ~-~- 29 Friday 03:03:25 711 711 712 712 713 -=== 2. 5.3 Set Device Time ===524 +=== 2.6.3 Set Device Time === 714 714 715 715 716 716 User need to set (% style="color:blue" %)**SYNCMOD=1**(%%) to enable sync time via MAC command. 717 717 718 -Once CPL03-LB Joined LoRaWAN network, it will send the MAC command (DeviceTimeReq) and the server will reply with (DeviceTimeAns) to send the current time toCPL03-LB. IfCPL03-LB fails to get the time from the server,CPL03-LB will use the internal time and wait for next time request (AT+SYNCTDC to set the time request period, default is 10 days).529 +Once DDS20-LB Joined LoRaWAN network, it will send the MAC command (DeviceTimeReq) and the server will reply with (DeviceTimeAns) to send the current time to DDS20-LB. If DDS20-LB fails to get the time from the server, DDS20-LB will use the internal time and wait for next time request (AT+SYNCTDC to set the time request period, default is 10 days). 719 719 720 720 (% style="color:red" %)**Note: LoRaWAN Server need to support LoRaWAN v1.0.3(MAC v1.0.3) or higher to support this MAC command feature, Chirpstack,TTN V3 v3 and loriot support but TTN V3 v2 doesn't support. If server doesn't support this command, it will through away uplink packet with this command, so user will lose the packet with time request for TTN V3 v2 if SYNCMOD=1.** 721 721 722 722 723 -=== 2. 5.4 Poll sensor value ===534 +=== 2.6.4 Poll sensor value === 724 724 725 725 726 726 Users can poll sensor values based on timestamps. Below is the downlink command. ... ... @@ -743,7 +743,7 @@ 743 743 ))) 744 744 745 745 ((( 746 -Uplink Internal =5s,means CPL03-LB will send one packet every 5s. range 5~~255s.557 +Uplink Internal =5s,means DDS20-LB will send one packet every 5s. range 5~~255s. 747 747 ))) 748 748 749 749 ... ... @@ -750,24 +750,24 @@ 750 750 == 2.7 Frequency Plans == 751 751 752 752 753 -The CPL03-LB uses OTAA mode and below frequency plans by default. If user want to use it with different frequency plan, please refer the AT command sets.564 +The DDS20-LB uses OTAA mode and below frequency plans by default. If user want to use it with different frequency plan, please refer the AT command sets. 754 754 755 755 [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20Frequency%20Band/>>http://wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20Frequency%20Band/]] 756 756 757 757 758 -= 3. Configure CPL03-LB =569 += 3. Configure DDS20-LB = 759 759 760 760 == 3.1 Configure Methods == 761 761 762 762 763 - CPL03-LB supports below configure method:574 +DDS20-LB supports below configure method: 764 764 765 765 * AT Command via Bluetooth Connection (**Recommended**): [[BLE Configure Instruction>>http://wiki.dragino.com/xwiki/bin/view/Main/BLE%20Bluetooth%20Remote%20Configure/]]. 577 + 766 766 * AT Command via UART Connection : See [[UART Connection>>http://wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H2.3UARTConnectionforSN50v3basemotherboard]]. 579 + 767 767 * LoRaWAN Downlink. Instruction for different platforms: See [[IoT LoRaWAN Server>>http://wiki.dragino.com/xwiki/bin/view/Main/]] section. 768 768 769 - 770 - 771 771 == 3.2 General Commands == 772 772 773 773 ... ... @@ -774,6 +774,7 @@ 774 774 These commands are to configure: 775 775 776 776 * General system settings like: uplink interval. 588 + 777 777 * LoRaWAN protocol & radio related command. 778 778 779 779 They are same for all Dragino Devices which support DLWS-005 LoRaWAN Stack. These commands can be found on the wiki: ... ... @@ -781,10 +781,10 @@ 781 781 [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/>>http://wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/]] 782 782 783 783 784 -== 3.3 Commands special design for CPL03-LB ==596 +== 3.3 Commands special design for DDS20-LB == 785 785 786 786 787 -These commands only valid for CPL03-LB, as below:599 +These commands only valid for DDS20-LB, as below: 788 788 789 789 790 790 === 3.3.1 Set Transmit Interval Time === ... ... @@ -826,232 +826,12 @@ 826 826 Example 1: Downlink Payload: 0100001E ~/~/ Set Transmit Interval (TDC) = 30 seconds 827 827 ))) 828 828 * ((( 829 -Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds 830 - 831 - 832 - 641 +Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds 833 833 ))) 834 834 835 -=== 3.3.2 QuitAT Command ===644 +=== 3.3.2 Set Interrupt Mode === 836 836 837 837 838 -Feature: Quit AT Command mode, so user needs to input the password again before using AT Commands. 839 - 840 -(% style="color:blue" %)**AT Command: AT+DISAT** 841 - 842 -(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:452px" %) 843 -|=(% style="width: 155px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 198px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 99px;background-color:#D9E2F3;color:#0070C0" %)**Response** 844 -|(% style="width:155px" %)AT+DISAT|(% style="width:198px" %)Quit AT Commands mode|(% style="width:96px" %)OK 845 - 846 -(% style="color:blue" %)**Downlink Command:** 847 - 848 -No downlink command for this feature. 849 - 850 - 851 -=== 3.3.3 Get Device Status === 852 - 853 - 854 -Send a LoRaWAN downlink to ask device send Alarm settings. 855 - 856 -(% style="color:blue" %)**Downlink Payload: **(%%)0x26 01 857 - 858 -Sensor will upload Device Status via FPORT=5. See payload section for detail. 859 - 860 - 861 -=== 3.3.4 Enable / Disable Alarm === 862 - 863 - 864 -Feature: Enable/Disable Alarm for open/close event. Default value 0. 865 - 866 -(% style="color:blue" %)**AT Command:** 867 - 868 -(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:520px" %) 869 -|(% style="background-color:#d9e2f3; color:#0070c0; width:154px" %)**Command Example**|(% style="background-color:#d9e2f3; color:#0070c0; width:278px" %)**Function**|(% style="background-color:#d9e2f3; color:#0070c0; width:88px" %)**Response** 870 -|(% style="width:154px" %)AT+DISALARM=1|(% style="width:278px" %)End node will only send packets in TDC time.|OK 871 -|(% style="width:154px" %)AT+DISALARM=0|(% style="width:278px" %)End node will send packets in TDC time or status change for door sensor|OK 872 - 873 -(% style="color:blue" %)**Downlink Command:** 874 - 875 -**0xA7 01** ~/~/ Same As AT+DISALARM=1 876 - 877 -**0xA7 00 ** ~/~/ Same As AT+DISALARM=0 878 - 879 - 880 -=== 3.3.5 Alarm Base on Timeout === 881 - 882 - 883 -((( 884 -CPL03-LB can monitor the timeout for a status change, this feature can be used to monitor some events such as door opening too long etc. Related Parameters are: 885 -))) 886 - 887 - 888 -((( 889 -(% style="color:#4f81bd" %)**1. Keep Status: Status to be monitor** 890 -))) 891 - 892 -((( 893 -**Keep Status = 1**: Monitor Close to Open event 894 -))) 895 - 896 -((( 897 -**Keep Status = 0**: Monitor Open to Close event 898 -))) 899 - 900 - 901 -((( 902 -(% style="color:#4f81bd" %)**2. Keep Time: Timeout to send an Alarm** 903 -))) 904 - 905 -((( 906 -Range 0 ~~ 65535(0xFFFF) seconds. 907 -))) 908 - 909 -((( 910 -If** keep time = 0**, Disable Alarm Base on Timeout feature. 911 -))) 912 - 913 -((( 914 -If **keep time > 0**, device will monitor the keep status event and send an alarm when status doesn’t change after timeout. 915 -))) 916 - 917 - 918 -((( 919 -(% style="color:#4f81bd" %)**AT Command**(%%) to configure: 920 -))) 921 - 922 -((( 923 -(% style="color:blue" %)**AT+TTRIG=1,30**(%%) ~-~-> When the **Keep Status** change from connect to disconnect, and device remains in disconnect status for more than 30 seconds. CPL03-LB will send an uplink packet, the [[Alarm bit>>||anchor="H2.3.3Real-TimeOpen2FCloseStatus2CUplinkFPORT3D2"]] (the second bit of 1^^st^^ byte of payload) on this uplink packet is set to 1. 924 -))) 925 - 926 -((( 927 -(% style="color:blue" %)**AT+TTIG=0,0 **(%%) ~-~-> Default Value, disable timeout Alarm. 928 -))) 929 - 930 - 931 -((( 932 -(% style="color:#4f81bd" %)**Downlink Command**(%%) to configure: 933 -))) 934 - 935 -((( 936 -**Command: 0xA9 aa bb cc** 937 -))) 938 - 939 -((( 940 -**A9: **Command Type Code 941 -))) 942 - 943 -((( 944 -**aa: **status to be monitored 945 -))) 946 - 947 -((( 948 -**bb cc: **timeout. 949 -))) 950 - 951 - 952 -((( 953 -If user send 0xA9 01 00 1E: equal to AT+TTRIG=1,30 954 -))) 955 - 956 -((( 957 -Or 958 -))) 959 - 960 -((( 961 -0xA9 00 00 00: Equal to AT+TTRIG=0,0. Disable timeout Alarm. 962 -))) 963 - 964 - 965 -=== 3.3.6 Clear Flash Record === 966 - 967 - 968 -Feature: Clear flash storage for data log feature. 969 - 970 -(% style="color:blue" %)**AT Command: AT+CLRDTA** 971 - 972 -(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:500px" %) 973 -|=(% style="width: 157px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 169px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 174px;background-color:#D9E2F3;color:#0070C0" %)**Response** 974 -|(% style="width:157px" %)AT+CLRDTA|(% style="width:169px" %)Clear flash storage for data log feature.|Clear all stored sensor data… OK 975 - 976 -((( 977 -(% style="color:blue" %)**Downlink Command:** 978 -))) 979 - 980 -((( 981 -* **Example**: 0xA301 ~/~/ Same as AT+CLRDTA 982 -))) 983 - 984 - 985 - 986 -=== 3.3.7 Set trigger mode === 987 - 988 - 989 -Feature: Set the trigger interrupt mode. 990 - 991 -(% style="color:blue" %)**AT Command: AT+TTRMOD** 992 - 993 -(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:495px" %) 994 -|=(% style="width: 157px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 246px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 92px;background-color:#D9E2F3;color:#0070C0" %)**Response** 995 -|(% style="width:157px" %)((( 996 -AT+TTRMOD=1 997 -)))|(% style="width:156px" %)Count and trigger from open to close (rising edge)|(% style="width:89px" %)((( 998 -((( 999 -OK 1000 -))) 1001 -))) 1002 -|(% style="width:157px" %)((( 1003 -AT+TTRMOD=0 1004 -)))|(% style="width:156px" %)Count and trigger from close to open (falling edge)|(% style="width:89px" %)((( 1005 -OK 1006 -))) 1007 - 1008 -(% style="color:blue" %)**Downlink Command:** 1009 - 1010 -* **Example**: 0xA401 ~/~/ Same as AT+ TTRMOD =1 1011 - 1012 - 1013 - 1014 -=== 3.3.8 Set the calculate flag === 1015 - 1016 - 1017 -Feature: Set the calculate flag 1018 - 1019 -(% style="color:blue" %)**AT Command: AT+CALCFLAG** 1020 - 1021 -(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:461px" %) 1022 -|=(% style="width: 158px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 193px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 110px;background-color:#D9E2F3;color:#0070C0" %)**Response** 1023 -|(% style="width:158px" %)AT+CALCFLAG =1|(% style="width:192px" %)Set the calculate flag to 1.|(% style="width:109px" %)OK 1024 -|(% style="width:158px" %)AT+CALCFLAG =2|(% style="width:192px" %)Set the calculate flag to 2.|(% style="width:109px" %)OK 1025 - 1026 -(% style="color:blue" %)**Downlink Command:** 1027 - 1028 -* **Example**: 0XA501 ~/~/ Same as AT+CALCFLAG =1 1029 - 1030 - 1031 - 1032 -=== 3.3.9 Set count number === 1033 - 1034 - 1035 -Feature: Manually set the count number 1036 - 1037 -(% style="color:blue" %)**AT Command: AT+SETCNT** 1038 - 1039 -(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:479px" %) 1040 -|=(% style="width: 160px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 223px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 96px;background-color:#D9E2F3;color:#0070C0" %)**Response** 1041 -|(% style="width:160px" %)AT+ SETCNT =0|(% style="width:221px" %)Set the count number to 0.|(% style="width:95px" %)OK 1042 -|(% style="width:160px" %)AT+ SETCNT =100|(% style="width:221px" %)Set the count number to 100.|(% style="width:95px" %)OK 1043 - 1044 -(% style="color:blue" %)**Downlink Command:** 1045 - 1046 -* **Example**: 0xA6000001 ~/~/ Same as AT+ SETCNT =1 1047 - 1048 -* **Example**: 0xA6000064 ~/~/ Same as AT+ SETCNT =100 1049 - 1050 - 1051 - 1052 -=== 3.3.10 Set Interrupt Mode === 1053 - 1054 - 1055 1055 Feature, Set Interrupt mode for PA8 of pin. 1056 1056 1057 1057 When AT+INTMOD=0 is set, PA8 is used as a digital input port. ... ... @@ -1083,83 +1083,79 @@ 1083 1083 1084 1084 * Example 2: Downlink Payload: 06000003 ~/~/ Set the interrupt mode to rising edge trigger 1085 1085 678 += 4. Battery & Power Consumption = 1086 1086 1087 1087 1088 - ===3.3.11SetPowerOutputDuration===681 +DDS20-LB use ER26500 + SPC1520 battery pack. See below link for detail information about the battery info and how to replace. 1089 1089 683 +[[**Battery Info & Power Consumption Analyze**>>http://wiki.dragino.com/xwiki/bin/view/Main/How%20to%20calculate%20the%20battery%20life%20of%20Dragino%20sensors%3F/]] . 1090 1090 1091 -Control the output duration 5V . Before each sampling, device will 1092 1092 1093 - ~1.first enablethe power outputtoexternalsensor,686 += 5. OTA Firmware update = 1094 1094 1095 -2. keep it on as per duration, read sensor value and construct uplink payload 1096 1096 1097 -3. final, close the power output. 689 +(% class="wikigeneratedid" %) 690 +User can change firmware DDS20-LB to: 1098 1098 1099 - (%style="color:blue"%)**AT Command:AT+5VT**692 +* Change Frequency band/ region. 1100 1100 1101 -(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %) 1102 -|=(% style="width: 155px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 197px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 158px;background-color:#D9E2F3;color:#0070C0" %)**Response** 1103 -|(% style="width:154px" %)AT+5VT=?|(% style="width:196px" %)Show 5V open time.|(% style="width:157px" %)0 (default) 1104 -OK 1105 -|(% style="width:154px" %)AT+5VT=500|(% style="width:196px" %)Close after a delay of 1000 milliseconds.|(% style="width:157px" %)OK 694 +* Update with new features. 1106 1106 1107 - (%style="color:blue"%)**Downlink Command: 0x07**696 +* Fix bugs. 1108 1108 1109 -F ormat:CommandCode(0x07)followedby2bytes.698 +Firmware and changelog can be downloaded from : **[[Firmware download link>>url:https://www.dropbox.com/sh/ph4uyz0rchflrnw/AADr1f_5Sg30804NItpfOQbla?dl=0]]** 1110 1110 1111 - Thefirstand secondbytesarethetime to turn on.700 +Methods to Update Firmware: 1112 1112 1113 -* Example1:DownlinkPayload:070000 **~-~-->** AT+5VT=0702 +* (Recommanded way) OTA firmware update via wireless: [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/Firmware%20OTA%20Update%20for%20Sensors/>>url:http://wiki.dragino.com/xwiki/bin/view/Main/Firmware%20OTA%20Update%20for%20Sensors/]] 1114 1114 1115 -* Example2:DownlinkPayload:0701F4~-~-->** AT+5VT=500704 +* Update through UART TTL interface: **[[Instruction>>url:http://wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H1.LoRaSTv4baseHardware]]**. 1116 1116 1117 1117 707 += 6. FAQ = 1118 1118 1119 -= 4.Battery&PowerConsumption=709 +== 6.1 What is the frequency plan for DDS20-LB? == 1120 1120 1121 1121 1122 - CPL03-LB useER26500+SPC1520batterypack.Seebelow linkfordetailinformationaboutthebatteryinfodhowtoreplace.712 +DDS20-LB use the same frequency as other Dragino products. User can see the detail from this link: [[Introduction>>doc:Main.End Device Frequency Band.WebHome||anchor="H1.Introduction"]] 1123 1123 1124 -[[**Battery Info & Power Consumption Analyze**>>http://wiki.dragino.com/xwiki/bin/view/Main/How%20to%20calculate%20the%20battery%20life%20of%20Dragino%20sensors%3F/]] . 1125 1125 715 +== 6.2 Can I use DDS20-LB in condensation environment? == 1126 1126 1127 -= 5. OTA Firmware update = 1128 1128 718 +DDS20-LB is not suitable to be used in condensation environment. Condensation on the DDS20-LB probe will affect the reading and always got 0. 1129 1129 1130 -(% class="wikigeneratedid" %) 1131 -User can change firmware CPL03-LB to: 1132 1132 1133 - *ChangeFrequencyband/ region.721 += 7. Trouble Shooting = 1134 1134 1135 - *Updatewithnewfeatures.723 +== 7.1 Why I can't join TTN V3 in US915 / AU915 bands? == 1136 1136 1137 -* Fix bugs. 1138 1138 1139 - Firmwareand changelogcanbe downloadedfrom:**[[Firmware downloadlink>>url:https://www.dropbox.com/sh/kwqv57tp6pejias/AAAopYMATh1GM6fZ-VRCLrpDa?dl=0]]**726 +It is due to channel mapping. Please see below link: [[Frequency band>>doc:Main.LoRaWAN Communication Debug.WebHome||anchor="H2.NoticeofUS9152FCN4702FAU915Frequencyband"]] 1140 1140 1141 -Methods to Update Firmware: 1142 1142 1143 - *(Recommandedway) OTA firmware updatevia wireless: [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/Firmware%20OTA%20Update%20for%20Sensors/>>url:http://wiki.dragino.com/xwiki/bin/view/Main/Firmware%20OTA%20Update%20for%20Sensors/]]729 +== 7.2 AT Command input doesn't work == 1144 1144 1145 -* Update through UART TTL interface. **[[Instruction>>url:http://wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H1.LoRaSTv4baseHardware]]**. 1146 1146 732 +In the case if user can see the console output but can't type input to the device. Please check if you already include the (% style="color:blue" %)**ENTER**(%%) while sending out the command. Some serial tool doesn't send (% style="color:blue" %)**ENTER**(%%) while press the send key, user need to add ENTER in their string. 1147 1147 1148 1148 1149 -= 6.FAQ=735 +== 7.3 Why i always see 0x0000 or 0 for the distance value? == 1150 1150 1151 -== 6.1 AT Commands input doesn't work == 1152 1152 738 +((( 739 +LDDS20 has a strict [[**installation requirement**>>||anchor="H1.5A0InstallDDS20-LB"]]. Please make sure the installation method exactly follows up with the installation requirement. Otherwise, the reading might be always 0x00. 1153 1153 1154 -In the case if user can see the console output but can't type input to the device. Please check if you already include the (% style="color:green" %)**ENTER**(%%) while sending out the command. Some serial tool doesn't send (% style="color:green" %)**ENTER**(%%) while press the send key, user need to add ENTER in their string. 741 +If you have followed the instruction requirement exactly but still see the 0x00 reading issue, please. please double-check the decoder, you can check the raw payload to verify. 742 +))) 1155 1155 1156 1156 1157 -= 7. Order Info =745 += 8. Order Info = 1158 1158 1159 1159 1160 -Part Number: (% style="color:blue" %)** CPL03-LB-XXX**748 +Part Number: (% style="color:blue" %)**DDS20-LB-XXX** 1161 1161 1162 -(% style="color:red" %)**XXX**(%%): The default frequency band 750 +(% style="color:red" %)**XXX**(%%): **The default frequency band** 1163 1163 1164 1164 * (% style="color:red" %)**AS923**(%%): LoRaWAN AS923 band 1165 1165 ... ... @@ -1177,14 +1177,12 @@ 1177 1177 1178 1178 * (% style="color:red" %)**CN470**(%%): LoRaWAN CN470 band 1179 1179 768 += 9. Packing Info = 1180 1180 1181 1181 1182 -= 8. Packing Info = 1183 - 1184 - 1185 1185 (% style="color:#037691" %)**Package Includes**: 1186 1186 1187 -* CPL03-LB LoRaWANPulse/ContactSensor773 +* DDS20-LB LoRaWAN Ultrasonic Liquid Level Sensor x 1 1188 1188 1189 1189 (% style="color:#037691" %)**Dimension and weight**: 1190 1190 ... ... @@ -1196,11 +1196,9 @@ 1196 1196 1197 1197 * Weight / pcs : g 1198 1198 785 += 10. Support = 1199 1199 1200 1200 1201 -= 9. Support = 1202 - 1203 - 1204 1204 * Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule. 1205 1205 1206 1206 * Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[Support@dragino.cc>>mailto:Support@dragino.cc]].
- image-20230530135929-2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +87.6 KB - Content
- image-20230530140053-1.jpeg
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +1.3 MB - Content
- image-20230612170349-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +164.2 KB - Content
- image-20230612170943-2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +86.4 KB - Content
- image-20230612171032-3.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +86.4 KB - Content
- image-20230613100900-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +184.0 KB - Content
- image-20230613102426-2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +89.3 KB - Content
- image-20230613102459-3.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +89.3 KB - Content
- image-20230613133647-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +213.6 KB - Content
- image-20230613133716-2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +165.8 KB - Content
- image-20230613140115-3.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +92.1 KB - Content
- image-20230613140140-4.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +92.1 KB - Content
- image-20230613143052-5.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +21.8 KB - Content
- image-20230613143125-6.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +24.7 KB - Content