Changes for page DS20L -- LoRaWAN Smart Distance Detector User Manual 01
Last modified by Mengting Qiu on 2023/12/14 11:15
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 2 added, 0 removed)
Details
- Page properties
-
- Title
-
... ... @@ -1,1 +1,1 @@ 1 - S31-LB/ S31B-LBLoRaWANOutdoor Temperature& HumiditySensor User Manual1 +CPL03-LB -- LoRaWAN Pulse/Contact Sensor User Manual - Content
-
... ... @@ -1,9 +1,7 @@ 1 1 (% style="text-align:center" %) 2 -[[image: S31-B.jpg]]2 +[[image:image-20230530084608-2.jpeg||height="707" width="707"]] 3 3 4 4 5 - 6 - 7 7 **Table of Contents:** 8 8 9 9 {{toc/}} ... ... @@ -15,36 +15,40 @@ 15 15 16 16 = 1. Introduction = 17 17 18 -== 1.1 What is S31x-LB LoRaWANTemperature& HumiditySensor ==16 +== 1.1 What is CPL03-LB LoRaWAN Pulse/Contact Sensor == 19 19 20 20 21 -The Dragino S31x-LB is a (% style="color:blue" %)**LoRaWANTemperatureand HumiditySensor**(%%) for Internet of Things solution. Itis usedto measurethe(% style="color:blue" %)**surroundingenvironment temperatureandrelativeair humidityprecisely**(%%), and then upload to IoT server via LoRaWAN wireless protocol.19 +The Dragino CPL03-LB is a (% style="color:blue" %)**LoRaWAN Contact Sensor**(%%) for Internet of Things solution. It detects dry contact status, open time, open counts, and then upload to IoT server via LoRaWAN wireless protocol. 22 22 23 -The temperature & humiditysensorusedinS31x-LBisSHT31,whichis fully calibrated,linearized,andtemperaturecompensateddigitaloutputfrom Sensirion,it provides a strongreliabilityandlong-termstability.TheSHT31isfixed ina(%style="color:blue" %)**waterproofanti-condensationcasing**(%%) forlongterm use.21 +The CPL03-LB will send periodically data every day as well as for each dry contact action. It also counts the contact open times and calculate last open duration. User can also disable the uplink for each open/close event, instead, device can count each open event and uplink periodically. 24 24 25 -The LoRa wireless technology used in S31x-LB allows device to send data and reach extremely long ranges at low data-rates. It provides ultra-long range spread spectrum communication and high interference immunity whilst minimizing current consumption.23 +The LoRa wireless technology used in CPL03-LB allows device to send data and reach extremely long ranges at low data-rates. It provides ultra-long range spread spectrum communication and high interference immunity whilst minimizing current consumption. 26 26 27 - S31x-LBsupports(% style="color:blue" %)**Temperature& Humdityalarm feature**(%%), user can settemperaturealarm for instant notice.S31x-LB supports Datalog feature, it can save the data when there is no LoRaWAN network and uplink when network recover.25 +CPL03-LB (% style="color:blue" %)**supports open alarm feature**(%%), user can set open alarm for instant notice. CPL03-LB (% style="color:blue" %)**supports Datalog feature**(%%), it can save the data when there is no LoRaWAN network and uplink when network recover. 28 28 29 - S31x-LB(%style="color:blue"%)**supportsBLEconfigure**(%%)and(%style="color:blue"%)**wirelessOTAupdate**(%%)which makeusereasytouse.27 +CPL03-LB is designed for outdoor use. It has a weatherproof enclosure and industrial level battery to work in low to high temperatures. 30 30 31 - S31x-LBis poweredby(% style="color:blue" %)**8500mAh Li-SOCI2battery**(%%),itis designed forlong term useupto5 years.29 +CPL03-LB (% style="color:blue" %)**supports BLE configure**(%%) and (% style="color:blue" %)**wireless OTA update**(%%) which make user easy to use. 32 32 33 - Each S31x-LB is pre-loadwithasetfuniquekeys for LoRaWANregistrations, register thesekeysto localLoRaWANserveranditwill autoconnectafterpower on.31 +CPL03-LB is powered by (% style="color:blue" %)**8500mAh Li-SOCI2 battery**(%%), it is designed for long term use up to 5 years. 34 34 33 +Each CPL03-LB is pre-load with a set of unique keys for LoRaWAN registrations, register these keys to local LoRaWAN server and it will auto connect after power on. 35 35 35 + 36 36 == 1.2 Features == 37 37 38 38 39 39 * LoRaWAN 1.0.3 Class A 40 +* Bands: CN470/EU433/KR920/US915/EU868/AS923/AU915/IN865 40 40 * Ultra-low power consumption 41 -* External3 meters SHT31 probe (For S31-LB)42 -* Measurerange -55°C ~~ 125°C42 +* Open/Close detect 43 +* Open/Close statistics 43 43 * Temperature & Humidity alarm 44 -* Bands: CN470/EU433/KR920/US915/EU868/AS923/AU915/IN865 45 +* supports open alarm feature 46 +* supports Datalog feature 45 45 * Support Bluetooth v5.1 and LoRaWAN remote configure 46 46 * Support wireless OTA update firmware 47 -* Uplink on periodically 49 +* Uplink on periodically and open/close event 48 48 * Downlink to change configure 49 49 * 8500mAh Battery for long term use 50 50 ... ... @@ -56,20 +56,6 @@ 56 56 * Supply Voltage: built in 8500mAh Li-SOCI2 battery , 2.5v ~~ 3.6v 57 57 * Operating Temperature: -40 ~~ 85°C 58 58 59 -(% style="color:#037691" %)**Temperature Sensor:** 60 - 61 -* Range: -40 to + 80°C 62 -* Accuracy: ±0.2 @ 0-90 °C 63 -* Resolution: 0.1°C 64 -* Long Term Shift: <0.03 °C/yr 65 - 66 -(% style="color:#037691" %)**Humidity Sensor: ** 67 - 68 -* Range: 0 ~~ 99.9% RH 69 -* Accuracy: ± 2%RH ( 0 ~~ 100%RH) 70 -* Resolution: 0.01% RH 71 -* Long Term Shift: <0.25 %RH/yr 72 - 73 73 (% style="color:#037691" %)**LoRa Spec:** 74 74 75 75 * Frequency Range, Band 1 (HF): 862 ~~ 1020 Mhz ... ... @@ -90,9 +90,16 @@ 90 90 * Sleep Mode: 5uA @ 3.3v 91 91 * LoRa Transmit Mode: 125mA @ 20dBm, 82mA @ 14dBm 92 92 93 -== 1.4 Sleepmodeand workingmode==81 +== 1.4 Applications == 94 94 95 95 84 +* Open/Close Detection 85 +* Pulse meter application 86 +* Dry Contact Detection 87 + 88 +== 1.5 Sleep mode and working mode == 89 + 90 + 96 96 (% style="color:blue" %)**Deep Sleep Mode: **(%%)Sensor doesn't have any LoRaWAN activate. This mode is used for storage and shipping to save battery life. 97 97 98 98 (% style="color:blue" %)**Working Mode:** (%%)In this mode, Sensor will work as LoRaWAN Sensor to Join LoRaWAN network and send out sensor data to server. Between each sampling/tx/rx periodically, sensor will be in IDLE mode), in IDLE mode, sensor has the same power consumption as Deep Sleep mode. ... ... @@ -120,7 +120,7 @@ 120 120 == 1.6 BLE connection == 121 121 122 122 123 - S31x-LB support BLE remote configure.118 +CPL03-LB support BLE remote configure. 124 124 125 125 126 126 BLE can be used to configure the parameter of sensor or see the console output from sensor. BLE will be only activate on below case: ... ... @@ -137,35 +137,9 @@ 137 137 [[image:image-20230523174230-1.png]] 138 138 139 139 140 -== 1.8 HardwareVariant==135 +== 1.8 Mechanical == 141 141 142 142 143 -(% border="1" cellspacing="5" style="width:510px" %) 144 -|=(% style="width: 102px;background-color:#D9E2F3;color:#0070C0" %)Model|=(% style="width: 190px;background-color:#D9E2F3;color:#0070C0" %)Photo|=(% style="width: 218px;background-color:#D9E2F3;color:#0070C0" %)Probe Info 145 -|(% style="width:102px" %)((( 146 -S31-LB 147 -)))|(% style="width:190px" %)[[image:image-20230527093214-2.jpeg]]|(% style="width:297px" %)((( 148 -1 x SHT31 Probe 149 - 150 -Cable Length : 2 meters 151 - 152 - 153 -))) 154 -|(% style="width:102px" %)((( 155 -S31B-LB 156 -)))|(% style="width:190px" %)[[image:image-20230527093155-1.jpeg]]|(% style="width:297px" %)((( 157 -1 x SHT31 Probe 158 - 159 -Installed in device. 160 -))) 161 - 162 -(% style="display:none" %) 163 - 164 - 165 - 166 -== 1.9 Mechanical == 167 - 168 - 169 169 [[image:Main.User Manual for LoRaWAN End Nodes.D20-LBD22-LBD23-LB_LoRaWAN_Temperature_Sensor_User_Manual.WebHome@1675143884058-338.png]] 170 170 171 171 ... ... @@ -175,12 +175,12 @@ 175 175 [[image:Main.User Manual for LoRaWAN End Nodes.D20-LBD22-LBD23-LB_LoRaWAN_Temperature_Sensor_User_Manual.WebHome@1675143909447-639.png]] 176 176 177 177 178 -= 2. Configure S31x-LB to connect to LoRaWAN network =147 += 2. Configure CPL03-LB to connect to LoRaWAN network = 179 179 180 180 == 2.1 How it works == 181 181 182 182 183 -The S31x-LB is configured as (% style="color:#037691" %)**LoRaWAN OTAA Class A**(%%) mode by default. It has OTAA keys to join LoRaWAN network. To connect a local LoRaWAN network, you need to input the OTAA keys in the LoRaWAN IoT server and press the button to activate theS31x-LB. It will automatically join the network via OTAA and start to send the sensor value. The default uplink interval is 20 minutes.152 +The CPL03-LB is configured as (% style="color:#037691" %)**LoRaWAN OTAA Class A**(%%) mode by default. It has OTAA keys to join LoRaWAN network. To connect a local LoRaWAN network, you need to input the OTAA keys in the LoRaWAN IoT server and press the button to activate the CPL03-LB. It will automatically join the network via OTAA and start to send the sensor value. The default uplink interval is 20 minutes. 184 184 185 185 186 186 == 2.2 Quick guide to connect to LoRaWAN server (OTAA) == ... ... @@ -188,12 +188,12 @@ 188 188 189 189 Following is an example for how to join the [[TTN v3 LoRaWAN Network>>url:https://console.cloud.thethings.network/]]. Below is the network structure; we use the [[LPS8v2>>url:https://www.dragino.com/products/lora-lorawan-gateway/item/228-lps8v2.html]] as a LoRaWAN gateway in this example. 190 190 191 -The LPS8 V2 is already set to connected to [[TTN network >>url:https://console.cloud.thethings.network/]], so what we need to now is configure the TTN server.160 +The LPS8v2 is already set to connected to [[TTN network >>url:https://console.cloud.thethings.network/]], so what we need to now is configure the TTN server. 192 192 193 193 194 -(% style="color:blue" %)**Step 1:**(%%) Create a device in TTN with the OTAA keys from S31x-LB.163 +(% style="color:blue" %)**Step 1:**(%%) Create a device in TTN with the OTAA keys from CPL03-LB. 195 195 196 -Each S31x-LB is shipped with a sticker with the default device EUI as below:165 +Each CPL03-LB is shipped with a sticker with the default device EUI as below: 197 197 198 198 [[image:image-20230426084152-1.png||alt="图片-20230426084152-1.png" height="233" width="502"]] 199 199 ... ... @@ -222,10 +222,10 @@ 222 222 [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LSN50v2-S31-S31B%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20User%20Manual/WebHome/image-20220611161308-6.png?width=744&height=485&rev=1.1||alt="图片-20220611161308-6.png"]] 223 223 224 224 225 -(% style="color:blue" %)**Step 2:**(%%) Activate on S31x-LB194 +(% style="color:blue" %)**Step 2:**(%%) Activate on CPL03-LB 226 226 227 227 228 -Press the button for 5 seconds to activate the S31x-LB.197 +Press the button for 5 seconds to activate the CPL03-LB. 229 229 230 230 (% style="color:green" %)**Green led**(%%) will fast blink 5 times, device will enter (% style="color:blue" %)**OTA mode**(%%) for 3 seconds. And then start to JOIN LoRaWAN network. (% style="color:green" %)**Green led**(%%) will solidly turn on for 5 seconds after joined in network. 231 231 ... ... @@ -237,7 +237,7 @@ 237 237 === 2.3.1 Device Status, FPORT~=5 === 238 238 239 239 240 -Users can use the downlink command(**0x26 01**) to ask S31x-LB to send device configure detail, include device configure status.S31x-LB will uplink a payload via FPort=5 to server.209 +Users can use the downlink command(**0x26 01**) to ask CPL03-LB to send device configure detail, include device configure status. CPL03-LB will uplink a payload via FPort=5 to server. 241 241 242 242 The Payload format is as below. 243 243 ... ... @@ -249,10 +249,10 @@ 249 249 250 250 Example parse in TTNv3 251 251 252 -[[image:i mage-20230524144422-1.png||height="174" width="1080"]]221 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/CPL01%20LoRaWAN%20Outdoor%20PulseContact%20%20Sensor%20Manual/WebHome/1652859749264-179.png?width=723&height=275&rev=1.1||alt="1652859749264-179.png"]] 253 253 254 254 255 -(% style="color:#037691" %)**Sensor Model**(%%): For S31x-LB, this value is 0x0A224 +(% style="color:#037691" %)**Sensor Model**(%%): For CPL03-LB, this value is 0x0A 256 256 257 257 (% style="color:#037691" %)**Firmware Version**(%%): 0x0100, Means: v1.0.0 version 258 258 ... ... @@ -305,250 +305,466 @@ 305 305 Ex2: 0x0B49 = 2889mV 306 306 307 307 308 -=== 2.3.2 Data.FPORT~=2===277 +=== 2.3.2 Sensor Configuration, FPORT~=4 === 309 309 310 310 311 - SensorDataisuplinkviaFPORT=2280 +CPL01 will only send this command after getting the downlink command (0x26 02) from the server. 312 312 313 -(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:500px" %) 314 -|=(% style="width: 60px;background-color:#D9E2F3;color:#0070C0" %)((( 315 -**Size(bytes)** 316 -)))|=(% style="width: 40px;background-color:#D9E2F3;color:#0070C0" %)2|=(% style="width: 90px;background-color:#D9E2F3;color:#0070C0" %)4|=(% style="width: 150px; background-color: #D9E2F3;color:#0070C0" %)1|=(% style="width: 80px; background-color: #D9E2F3;color:#0070C0" %)**2**|=(% style="width: 80px; background-color: #D9E2F3;color:#0070C0" %)2 317 -|(% style="width:99px" %)**Value**|(% style="width:69px" %)((( 318 -Battery 319 -)))|(% style="width:130px" %)((( 320 -Unix TimeStamp 321 -)))|(% style="width:194px" %)((( 322 -Alarm Flag & MOD& Level of PA8 323 -)))|(% style="width:106px" %)((( 324 -Temperature 325 -)))|(% style="width:97px" %)((( 326 -Humidity 282 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %) 283 +|(% colspan="6" style="background-color:#d9e2f3; color:#0070c0; width:504px" %)**Sensor Configuration FPORT=4** 284 +|**Size(bytes)**|(% style="width:75px" %)**3**|(% style="width:77px" %)**1**|(% style="width:96px" %)**1**|(% style="width:158px" %)**2**|(% style="width:158px" %)**1** 285 +|**Value**|(% style="width:75px" %)TDC (unit:sec)|(% style="width:77px" %)Disalarm|(% style="width:96px" %)Keep status|(% style="width:158px" %)Keep time (unit: sec)|(% style="width:158px" %)Trigger mode 286 + 287 +* ((( 288 +(% style="color:#037691" %)** TDC: (default: 0x001C20)** 327 327 ))) 328 328 329 -[[image:image-20230524144456-2.png||height="180" width="1142"]] 291 +((( 292 +Uplink interval for the total pulse count, default value is 0x001C20 which is 7200 seconds = 2 hours. 330 330 294 + 295 +))) 331 331 332 -==== (% style="color:#4472c4" %)**Battery**(%%) ==== 297 +* ((( 298 +(% style="color:#037691" %)** Disalarm: (default: 0)** 299 +))) 333 333 334 -Sensor Battery Level. 301 +((( 302 +(% style="color:blue" %)** If Disalarm = 1**(%%), CPL01 will only send uplink at every TDC periodically. This is normally use for pulse meter application, in this application, there are many disconnect/connect event, and platform only care about the total number of pulse. 303 +))) 335 335 336 -Ex1: 0x0B45 = 2885mV 305 +((( 306 +(% style="color:blue" %)** If Disalarm = 0**(%%), CPL01 will send uplink at every TDC periodically. 337 337 338 -Ex2: 0x0B49 = 2889mV 308 + 309 +))) 339 339 311 +* ((( 312 +(% style="color:#037691" %)** Keep Status & Keep Time** 313 +))) 340 340 315 +((( 316 +Shows the configure value of [[Alarm Base on Timeout Feature>>||anchor="H3.5AlarmBaseonTimeout"]] 341 341 342 -==== (% style="color:#4472c4" %)**Temperature**(%%) ==== 318 + 319 +))) 343 343 344 -**Example**: 321 +* ((( 322 +(% style="color:#037691" %)** Trigger mode (default: 0)** 323 +))) 345 345 346 -If payload is: 0105H: (0105 & 8000 == 0), temp = 0105H /10 = 26.1 degree 325 +((( 326 +(% style="color:blue" %)** If Trigger mode = 0**(%%), count close to open event. 327 +))) 347 347 348 -If payload is: FF3FH : (FF3F & 8000 == 1) , temp = (FF3FH - 65536)/10 = -19.3 degrees. 329 +((( 330 +(% style="color:blue" %)** If Trigger mode = 1**(%%), count open to close event. 331 +))) 349 349 350 - (FF3F &8000:Judge whether the highestbit is1,when the highestbit is 1, it is negative)333 +[[image:1652860064987-743.png||height="152" width="730"]] 351 351 352 352 353 - ==== (% style="color:#4472c4"%)**Humidity**(%%)====336 +[[image:1652860079526-831.png||height="209" width="729"]] 354 354 355 355 356 - Read:0x(0197)=412Value:412/10=41.2,So41.2%339 +=== 2.3.3 Real-Time Open/Close Status, Uplink FPORT~=2 === 357 357 358 358 359 -==== (% style="color:#4472c4" %)**Alarm Flag & MOD & Level of PA8**(%%) ==== 342 +((( 343 +((( 344 +CPL01 will send this uplink **after** Device Status once join the LoRaWAN network successfully. And CPL01 will: 345 +))) 346 +))) 360 360 348 +((( 349 +((( 350 +periodically send this uplink every 2 hours, this interval [[can be changed>>||anchor="H3.1SetTransmitIntervalTime"]]. 351 +))) 352 +))) 361 361 362 -**Example:** 354 +((( 355 +((( 356 +Uplink Payload totals 11 bytes. 357 +))) 358 +))) 363 363 364 -If payload & 0x01 = 0x01 **~-~->** This is an Alarm Message.It means that the temperature and humidity exceed the alarm value or trigger an interrupt. 360 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:520px" %) 361 +|=(% colspan="5" style="background-color:#D9E2F3;color:#0070C0; width: 520px;" %)**Real-Time Open/Close Status, FPORT=2** 362 +|(% style="width:60px" %)**Size(bytes)**|(% style="width:65px" %)**1**|(% style="width:65px" %)**3**|(% style="width:240px" %)**3**|(% style="width:90px" %)**4** 363 +|(% style="width:101px" %)**Value**|(% style="width:133px" %)Status & [[Alarm>>||anchor="H3.5AlarmBaseonTimeout"]]|(% style="width:92px" %)Total pulse|(% style="width:247px" %)The last open duration (unit: min)|(% style="width:149px" %)[[Unix TimeStamp>>||anchor="H2.4.1UnixTimeStamp"]] 365 365 366 -If payload & 0x01 = 0x00 **~-~->** This is a normal uplink message, no alarm. 365 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:504px" %) 366 +|=(% colspan="4" style="background-color:#D9E2F3;color:#0070C0; width: 502px;" %)**Status & Alarm field** 367 +|(% style="width:60px" %)**Size(bit)**|(% style="width:70px" %)**6**|(% style="width:228px" %)**1**|(% style="width:146px" %)**1** 368 +|(% style="width:76px" %)Value|(% style="width:80px" %)Calculate Flag|(% style="width:208px" %)Alarm: 0: No Alarm; 1: Alarm|(% style="width:136px" %)Contact Status: 0: Open, 1: Close 367 367 368 -If payload & 0x80>>7 = 0x01 **~-~->** The PA8 is low level. 370 +* ((( 371 +(% style="color:#037691" %)** Calculate Flag** 372 +))) 369 369 370 -If payload & 0x80>>7 =0x00 **~-~->** The PA8 is high level. 374 +((( 375 +The calculate flag is a user define field, IoT server can use this filed to handle different meter with different pulse factor. For example, if there are 100 water meters, meter 1 ~~50 are 1 liter/pulse and meter 51 ~~ 100 has 1.5 liter/pulse. 376 +))) 371 371 372 -If payload >> 2 = 0x00 **~-~->** means MOD=1, This is a sampling uplink message. 378 +((( 379 +User can set calculate flag to 1 for meter 1~~50 and 2 for meter 51 ~~ 100, So IoT Server can use this field for calculation. 380 +))) 373 373 374 -If payload >> 2 = 0x31 **~-~->** means MOD=31, this message is a reply message for polling, this message contains the alarm settings. see [[this link>>path:#HPolltheAlarmsettings:]] for detail. 382 +((( 383 +Default value: 0. 384 +))) 375 375 386 +((( 387 +Range (6 bits): (b)000000 ~~ (b) 111111 388 +))) 376 376 377 -== 2.4 Payload Decoder file == 390 +((( 391 +Refer: [[Set Calculate Flag>>||anchor="H3.9Setthecalculateflag"]] 378 378 393 + 394 +))) 379 379 380 -In TTN, use can add a custom payload so it shows friendly reading 396 +* ((( 397 +(% style="color:#037691" %)** Alarm** 398 +))) 381 381 382 -In the page (% style="color:#037691" %)**Applications ~-~-> Payload Formats ~-~-> Custom ~-~-> decoder**(%%) to add the decoder from: 400 +((( 401 +See [[Alarm Base on Timeout>>||anchor="H3.5AlarmBaseonTimeout"]] 383 383 384 -[[https:~~/~~/github.com/dragino/dragino-end-node-decoder/tree/main/S31-LB%26S31B-LB>>https://github.com/dragino/dragino-end-node-decoder/tree/main/S31-LB%26S31B-LB]] 403 + 404 +))) 385 385 406 +* ((( 407 +(% style="color:#037691" %)** Contact Status** 408 +))) 386 386 387 -== 2.5 Datalog Feature == 410 +((( 411 +0: Open 412 +))) 388 388 414 +((( 415 +1: Close 389 389 390 -Datalog Feature is to ensure IoT Server can get all sampling data from Sensor even if the LoRaWAN network is down. For each sampling, S31x-LB will store the reading for future retrieving purposes. 417 + 418 +))) 391 391 420 +* ((( 421 +(% style="color:#037691" %)** Total pulse** 422 +))) 392 392 393 -=== 2.5.1 Ways to get datalog via LoRaWAN === 424 +((( 425 +Total pulse/counting base on dry [[contact trigger event>>||anchor="H2.3.2SensorConfiguration2CFPORT3D4"]] 426 +))) 394 394 428 +((( 429 +Range (3 Bytes) : 0x000000 ~~ 0xFFFFFF . Max: 16777215 395 395 396 -Set [[PNACKMD=1>>||anchor="H2.5.4DatalogUplinkpayload28FPORT3D329"]], S31x-LB will wait for ACK for every uplink, when there is no LoRaWAN network,S31x-LB will mark these records with non-ack messages and store the sensor data, and it will send all messages (10s interval) after the network recovery. 431 + 432 +))) 397 397 398 398 * ((( 399 - a)S31x-LB willdoanACK checkfor datarecords sendingto make sure every data arrive server.435 +(% style="color:#037691" %)** The last open duration** 400 400 ))) 401 -* ((( 402 -b) S31x-LB will send data in **CONFIRMED Mode** when PNACKMD=1, but S31x-LB won't re-transmit the packet if it doesn't get ACK, it will just mark it as a NONE-ACK message. In a future uplink if S31x-LB gets a ACK, S31x-LB will consider there is a network connection and resend all NONE-ACK messages. 437 + 438 +((( 439 +Dry Contact last open duration. 403 403 ))) 404 404 405 -Below is the typical case for the auto-update datalog feature (Set PNACKMD=1) 442 +((( 443 +Unit: min. 444 +))) 406 406 407 -[[image: http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/WebHome/image-20220703111700-2.png?width=1119&height=381&rev=1.1||alt="图片-20220703111700-2.png"height="381" width="1119"]]446 +[[image:1652860403792-491.png||height="153" width="735"]] 408 408 409 409 410 -=== 2. 5.2UnixTimeStamp ===449 +=== 2.3.4 Real-Time Open/Close Status, 3 pulse mode, Uplink FPORT~=6 === 411 411 412 412 413 - S31x-LBuses Unix TimeStamp format based on452 +(% style="color:red" %)**Note:** 414 414 415 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/WebHome/image-20220523001219-11.png?width=627&height=97&rev=1.1||alt="图片-20220523001219-11.png" height="97" width="627"]] 454 +* Firmware support for this mode is not released. If users want to test, please contact Dragino support. 455 +* Users need to run (% style="color:blue" %)**AT+MOD=3**(%%) to support this model after updating the firmware. 456 +* This mode doesn't support Historical Events and Datalog features. 416 416 417 - Usercan get thisime fromlink: [[https:~~/~~/www.epochconverter.com/>>url:https://www.epochconverter.com/]]:458 +(% style="color:blue" %)**CPL03-LB 3 Pulse Wiring:** 418 418 419 - Belowis theconverterexample460 +[[image:image-20221013153352-1.png||height="628" width="720"]] 420 420 421 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/WebHome/image-20220523001219-12.png?width=720&height=298&rev=1.1||alt="图片-20220523001219-12.png" height="298" width="720"]] 422 422 463 +(% style="color:blue" %)**Payload:** 423 423 424 - So, wecan useAT+TIMESTAMP=1611889405or downlink3060137afd00 to set thecurrent time 2021– Jan ~-~- 29 Friday 03:03:25465 +[[image:image-20221013153352-2.png||height="167" width="1215"]] 425 425 426 426 427 -=== 2.5.3 Set Device Time === 468 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:447px" %) 469 +|(% style="background-color:#d9e2f3; color:#0070c0; width:95px" %)**Size(bytes)**|(% style="background-color:#d9e2f3; color:#0070c0; width:61px" %)**1**|(% style="background-color:#d9e2f3; color:#0070c0; width:98px" %)**3**|(% style="background-color:#d9e2f3; color:#0070c0; width:98px" %)**3**|(% style="background-color:#d9e2f3; color:#0070c0; width:95px" %)**3** 470 +|(% style="width:93px" %)Value|(% style="width:59px" %)Status|(% style="width:98px" %)((( 471 +Port1 Total Pulse(PB14) 472 +)))|(% style="width:96px" %)((( 473 +Port2 Total Pulse(PB15) 474 +)))|(% style="width:94px" %)((( 475 +Port3 Total Pulse(PA4) 476 +))) 428 428 478 +(% style="color:blue" %)**Status:** 429 429 430 -User need to set (% style="color:blue" %)**SYNCMOD=1**(%%) to enable sync time via MAC command. 480 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:257px" %) 481 +|(% style="background-color:#d9e2f3; color:#0070c0; width:75px" %)**Size(bit)**|(% style="background-color:#d9e2f3; color:#0070c0; width:112px" %)**6**|(% style="background-color:#d9e2f3; color:#0070c0; width:70px" %)**2** 482 +|(% style="width:75px" %)Value|(% style="width:111px" %)Calculate Flag|(% style="width:68px" %)Reserve 431 431 432 - OnceS31x-LB Joined LoRaWAN network, it will sendtheMAC command(DeviceTimeReq)and the serverwill reply with (DeviceTimeAns) to send thecurrenttimeto S31x-LB.If S31x-LB fails to get the timefromtheserver,S31x-LBwilluse the internal timeand wait for next time request (AT+SYNCTDC to set the time request period,default is10 days).484 +(% style="color:red" %)**Max COUNT for each port is 16777215. Exceed this number will reset to 1.** 433 433 434 -(% style="color:red" %)**Note: LoRaWAN Server need to support LoRaWAN v1.0.3(MAC v1.0.3) or higher to support this MAC command feature, Chirpstack,TTN V3 v3 and loriot support but TTN V3 v2 doesn't support. If server doesn't support this command, it will through away uplink packet with this command, so user will lose the packet with time request for TTN V3 v2 if SYNCMOD=1.** 435 435 487 +(% style="color:blue" %)**Related AT Command:** 436 436 437 -= ==2.5.4DatalogUplinkpayload(FPORT~=3)===489 +(% style="color:#037691" %)**AT+TTRMOD1: Port1 count mode; 0: Signal falling edge(Default), 1: Signal raising edge** 438 438 491 + AT+TTRMOD1=0 Downlink Command: 0xA4 01 00 439 439 440 -T heDatalog uplinkswill use below payloadformat.493 + AT+TTRMOD1=1 Downlink Command: 0xA4 01 01 441 441 442 -**Retrieval data payload:** 443 443 444 -(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:680px" %) 445 -|=(% style="width: 80px;background-color:#D9E2F3" %)((( 446 -**Size(bytes)** 447 -)))|=(% style="width: 68px; background-color: rgb(217, 226, 243);" %)**2**|=(% style="width: 104px; background-color: rgb(217, 226, 243);" %)**2**|=(% style="width: 87px; background-color: rgb(217, 226, 243);" %)**2**|=(% style="width: 178px; background-color: rgb(217, 226, 243);" %)**1**|=(% style="width: 137px; background-color: rgb(217, 226, 243);" %)**4** 448 -|(% style="width:103px" %)**Value**|(% style="width:68px" %)((( 449 -ignore 450 -)))|(% style="width:104px" %)((( 451 -((( 452 -Humidity 453 -))) 496 +(% style="color:#037691" %)**AT+TTRMOD2: Port2 count mode; 0: Signal falling edge(Default), 1: Signal raising edge** 454 454 455 -((( 456 - 457 -))) 458 -)))|(% style="width:87px" %)((( 459 -Temperature 460 -)))|(% style="width:178px" %)((( 461 -Poll message flag & 498 + AT+TTRMOD1=0 Downlink Command: 0xA4 02 00 462 462 463 -A larmFlag&500 + AT+TTRMOD1=1 Downlink Command: 0xA4 02 01 464 464 465 -Level of PA8 466 -)))|(% style="width:137px" %)Unix Time Stamp 467 467 468 -**Po llmessageflag& AlarmFlag& Level of PA8:**503 +(% style="color:#037691" %)**AT+TTRMOD3: Port3 count mode; 0: Signal falling edge(Default), 1: Signal raising edge** 469 469 470 - [[image:image-20230524114302-1.png||height="115"width="736"]]505 + AT+TTRMOD1=0 Downlink Command: 0xA4 03 00 471 471 507 + AT+TTRMOD1=1 Downlink Command: 0xA4 03 01 472 472 473 -**No ACK Message**: 1: This message means this payload is fromn Uplink Message which doesn't get ACK from the server before ( for **PNACKMD=1** feature) 474 474 475 - **PollMessageFlag**::Thismessage is a pollmessagereply.510 +(% style="color:#037691" %)**AT+CALCFLAG: Calculate Flag ( Default : 0 )** 476 476 477 - *PollMessageFlagissetto1.512 + AT+CALCFLAG=aa 478 478 479 -* Each data entry is 11 bytes, to save airtime and battery, devices will send max bytes according to the current DR and Frequency bands. 480 480 481 - Forexample,inUS915 band,the maxpayload for different DR is:515 +(% style="color:blue" %)**Downlink Command: 0xA5 aa** 482 482 483 - **a)DR0:** maxis11bytesso one entryof data517 +(% style="color:#037691" %)**AT+COUNTMOD: Accumulative Mode; 0: Accumulative (Default),1: Reset after uplink.** 484 484 485 - **b)DR1:**maxis53bytessodeviceswillupload4entriesofdata(total44bytes)519 + AT+COUNTMOD=0 Downlink Command: 0x0B 00 486 486 487 - **c)DR2:**totalpayloadincludes11entriesof data521 + AT+COUNTMOD=1 Downlink Command: 0x0B 01 488 488 489 -**d) DR3: **total payload includes 22 entries of data. 490 490 491 - Ifdevisedoesn'thaveany datain the pollingtime.Device willuplink 11 bytes of 0524 +(% style="color:#037691" %)**AT+SETCNT: Set count value** 492 492 493 - **Example:**526 + AT+SETCNT=1,aa Downlink Command: 0xA6 01 aa aa aa 494 494 495 - IfS31x-LBhasbelow datainsideFlash:528 + AT+SETCNT=2,aa Downlink Command: 0xA6 02 aa aa aa 496 496 497 - [[image:image-20230524114654-2.png]]530 + AT+SETCNT=3,aa Downlink Command: 0xA6 03 aa aa aa 498 498 499 499 500 - Ifusersendsbelowdownlinkcommand: 31646D84E1646D856C05533 +(% style="color:blue" %)**Decode: **(%%)[[https:~~/~~/github.com/dragino/dragino-end-node-decoder>>https://github.com/dragino/dragino-end-node-decoder]] 501 501 502 -Where : Start time: 646D84E1 = time 23/5/24 03:30:41 503 503 504 - Stop time:646D856C=time23/5/2403:33:00536 +=== 2.3.5 Historical Door Open/Close Event, FPORT~=3 === 505 505 506 506 507 -**S31x-LB will uplink this payload.** 539 +((( 540 +CPL01 stores sensor values and users can retrieve these history values via the [[downlink command>>||anchor="H2.4DatalogFeature"]]. 541 +))) 508 508 509 -[[image:image-20230524114826-3.png||height="448" width="1244"]] 543 +((( 544 +The historical payload includes one or multiplies entries and every entry has the same payload as Real-Time open/close status. 545 +))) 510 510 547 +* ((( 548 +Each data entry is 11 bytes and has the same structure as [[Real-Time open/close status>>||anchor="H2.3.3Real-TimeOpen2FCloseStatus2CUplinkFPORT3D2"]], to save airtime and battery, CPL01 will send max bytes according to the current DR and Frequency bands. 549 +))) 550 + 511 511 ((( 512 - 00 00 02 36 01 10 40 64 6D 84 E1 00 00 02 37 01 10 40 64 6D 84F800000237 010F 40 64 6D 85040000023A010F 40 64 6D85 18 00 00 02 3C 01 0F 40 64 6D 85 36 00 00 02 3D 01 0E 40 64 6D 85 3F 00 00 02 3F 01 0E 40 64 6D 85 60 00 00 02 40 01 0E 40 64 6D 85 6A552 +For example, in the US915 band, the max payload for different DR is: 513 513 ))) 514 514 515 515 ((( 516 - Wherethefirst11 bytesisforthefirstentry:556 +a) (% style="color:blue" %)**DR0**(%%): max is 11 bytes so one entry of data 517 517 ))) 518 518 519 519 ((( 520 - 00000236011040646D84E1560 +b) (% style="color:blue" %)**DR1**(%%): max is 53 bytes so devices will upload 4 entries of data (total 44 bytes) 521 521 ))) 522 522 523 523 ((( 524 - **Hum**=0x0236/10=56.6564 +c) (% style="color:blue" %)**DR2**(%%): total payload includes 11 entries of data 525 525 ))) 526 526 527 527 ((( 528 -** Temp**=0x0110/10=27.2568 +d) (% style="color:blue" %)**DR3**(%%): total payload includes 22 entries of data. 529 529 ))) 530 530 531 531 ((( 532 -**poll message flag & Alarm Flag & Level of PA8**=0x40,means reply data,sampling uplink message,the PA8 is low level. 572 +If CPL01 doesn't have any data in the polling time. It will uplink 11 bytes of 0 573 + 574 + 533 533 ))) 534 534 577 +(% style="color:blue" %)** Downlink:** 578 + 579 +(% class="box" %) 535 535 ((( 536 -** Unixtime**is0x646D84E1=1684899041s=23/5/2403:30:41581 +**0x31 61 E9 3A D4 61 E9 3D E0 05** 537 537 ))) 538 538 584 +[[image:1652861353248-624.png||height="189" width="720"]] 539 539 540 -(% aria-label="数据 URI 图像图像小部件" contenteditable="false" role="region" style="background-image:url(http://wiki1.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" tabindex="-1" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||alt="数据 URI 图片" data-widget="image" draggable="true" height="15" role="presentation" title="单击并拖动以移动" width="15"]](% aria-label="数据 URI 图像图像小部件" contenteditable="false" role="region" style="background-image:url(http://wiki1.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220, 220, 220, 0.5); display:none" tabindex="-1" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||alt="数据 URI 图片" draggable="true" height="15" role="presentation" title="单击并拖动以移动" width="15"]](% aria-label="数据 URI 图像图像小部件" contenteditable="false" role="region" style="background-image:url(http://wiki1.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" tabindex="-1" title="单击并拖动以调整大小" %)的(% aria-label="数据 URI 图像图像小部件" contenteditable="false" role="region" style="background-image:url(http://wiki1.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" tabindex="-1" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||alt="数据 URI 图片" data-widget="image" draggable="true" height="15" role="presentation" title="单击并拖动以移动" width="15"]](% aria-label="数据 URI 图像图像小部件" contenteditable="false" role="region" style="background-image:url(http://wiki1.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220, 220, 220, 0.5); display:none" tabindex="-1" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||alt="数据 URI 图片" draggable="true" height="15" role="presentation" title="单击并拖动以移动" width="15"]](% aria-label="数据 URI 图像图像小部件" contenteditable="false" role="region" style="background-image:url(http://wiki1.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" tabindex="-1" title="单击并拖动以调整大小" %)的 541 541 542 - ==2.6 TemperatureAlarm Feature==587 +(% style="color:blue" %)** Uplink:** 543 543 589 +(% class="box" %) 590 +((( 591 +**0E 00 23 E6 00 00 00 61 E9 3B 04 0E 00 23 E6 00 00 00 61 E9 3B 25 0D 00 00 00 00 00 00 61 E9 3B C8 0E 00 00 02 00 00 00 61 E9 3B D4 0E 00 00 06 00 00 00 61 E9 3B DB 01 00 00 00 00 00 00 61 E9 3C 91 01 00 00 00 00 00 00 61 E9 3C A1 0D 00 00 00 00 00 00 61 E9 3C BC 0E 00 00 07 00 00 00 61 E9 3C D6 00 00 00 00 00 00 00 61 E9 3D A6** 592 +))) 544 544 545 - S31x-LBwork flow with Alarmfeature.594 +(% style="color:#037691" %)** ** 546 546 596 +(% style="color:#037691" %)**Parsed Value:** 547 547 548 -[[image:image-20230524110125-3.png||height="768" width="1115"]] 598 +((( 599 +[ALARM, PIN_STATUS, TOTAL_PULSE, CALCULATE_FLAG, LAST_OPEN_DURATION, TIME] 600 +))) 549 549 602 +((( 603 + 604 +))) 550 550 606 +((( 607 +[TRUE, CLOSE, 9190, 3, 0, 2022-01-20 10:35:48], 608 +))) 551 551 610 +((( 611 +[TRUE, CLOSE, 9190, 3, 0, 2022-01-20 10:36:21], 612 +))) 613 + 614 +((( 615 +[FALSE, OPEN, 0, 3, 0, 2022-01-20 10:39:04], 616 +))) 617 + 618 +((( 619 +[TRUE, CLOSE, 2, 3, 0, 2022-01-20 10:39:16], 620 +))) 621 + 622 +((( 623 +[TRUE, CLOSE, 6, 3, 0, 2022-01-20 10:39:23], 624 +))) 625 + 626 +((( 627 +[FALSE, OPEN, 0, 0, 0, 2022-01-20 10:42:25], 628 +))) 629 + 630 +((( 631 +[FALSE, OPEN, 0, 0, 0, 2022-01-20 10:42:41], 632 +))) 633 + 634 +((( 635 +[FALSE, OPEN, 0, 3, 0, 2022-01-20 10:43:08], 636 +))) 637 + 638 +((( 639 +[TRUE, CLOSE, 7, 3, 0, 2022-01-20 10:43:34], 640 +))) 641 + 642 +((( 643 +[FALSE, CLOSE, 0, 0, 0, 2022-01-20 10:47:02], 644 + 645 + 646 +))) 647 + 648 +[[image:1652861480446-216.png]] 649 + 650 + 651 +== 2.4 Payload Decoder file == 652 + 653 + 654 +In TTN, use can add a custom payload so it shows friendly reading 655 + 656 +In the page (% style="color:#037691" %)**Applications ~-~-> Payload Formats ~-~-> Custom ~-~-> decoder**(%%) to add the decoder from: [[https:~~/~~/github.com/dragino/dragino-end-node-decoder>>https://github.com/dragino/dragino-end-node-decoder]] 657 + 658 + 659 +== 2.5 Datalog Feature == 660 + 661 + 662 +Datalog Feature is to ensure IoT Server can get all sampling data from Sensor even if the LoRaWAN network is down. For each sampling, S31x-LB will store the reading for future retrieving purposes. 663 + 664 + 665 +=== 2.5.1 Ways to get datalog via LoRaWAN === 666 + 667 + 668 +Set [[PNACKMD=1>>||anchor="H2.5.4DatalogUplinkpayload28FPORT3D329"]], S31x-LB will wait for ACK for every uplink, when there is no LoRaWAN network,S31x-LB will mark these records with non-ack messages and store the sensor data, and it will send all messages (10s interval) after the network recovery. 669 + 670 +* ((( 671 +a) S31x-LB will do an ACK check for data records sending to make sure every data arrive server. 672 +))) 673 +* ((( 674 +b) S31x-LB will send data in **CONFIRMED Mode** when PNACKMD=1, but S31x-LB won't re-transmit the packet if it doesn't get ACK, it will just mark it as a NONE-ACK message. In a future uplink if S31x-LB gets a ACK, S31x-LB will consider there is a network connection and resend all NONE-ACK messages. 675 +))) 676 + 677 +Below is the typical case for the auto-update datalog feature (Set PNACKMD=1) 678 + 679 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/WebHome/image-20220703111700-2.png?width=1119&height=381&rev=1.1||alt="图片-20220703111700-2.png" height="381" width="1119"]] 680 + 681 + 682 +=== 2.5.2 Unix TimeStamp === 683 + 684 + 685 +S31x-LB uses Unix TimeStamp format based on 686 + 687 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/WebHome/image-20220523001219-11.png?width=627&height=97&rev=1.1||alt="图片-20220523001219-11.png" height="97" width="627"]] 688 + 689 +User can get this time from link: [[https:~~/~~/www.epochconverter.com/>>url:https://www.epochconverter.com/]] : 690 + 691 +Below is the converter example 692 + 693 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/WebHome/image-20220523001219-12.png?width=720&height=298&rev=1.1||alt="图片-20220523001219-12.png" height="298" width="720"]] 694 + 695 + 696 +So, we can use AT+TIMESTAMP=1611889405 or downlink 3060137afd00 to set the current time 2021 – Jan ~-~- 29 Friday 03:03:25 697 + 698 + 699 +=== 2.5.3 Set Device Time === 700 + 701 + 702 +User need to set (% style="color:blue" %)**SYNCMOD=1**(%%) to enable sync time via MAC command. 703 + 704 +Once S31x-LB Joined LoRaWAN network, it will send the MAC command (DeviceTimeReq) and the server will reply with (DeviceTimeAns) to send the current time to S31x-LB. If S31x-LB fails to get the time from the server, S31x-LB will use the internal time and wait for next time request (AT+SYNCTDC to set the time request period, default is 10 days). 705 + 706 +(% style="color:red" %)**Note: LoRaWAN Server need to support LoRaWAN v1.0.3(MAC v1.0.3) or higher to support this MAC command feature, Chirpstack,TTN V3 v3 and loriot support but TTN V3 v2 doesn't support. If server doesn't support this command, it will through away uplink packet with this command, so user will lose the packet with time request for TTN V3 v2 if SYNCMOD=1.** 707 + 708 + 709 + 710 +=== 2.5.4 Poll sensor value === 711 + 712 + 713 +Users can poll sensor values based on timestamps. Below is the downlink command. 714 + 715 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:425.818px" %) 716 +|(% colspan="4" style="background-color:#d9e2f3; color:#0070c0; width:423px" %)**Downlink Command to poll Open/Close status (0x31)** 717 +|(% style="width:58px" %)**1byte**|(% style="width:127px" %)**4bytes**|(% style="width:124px" %)**4bytes**|(% style="width:114px" %)**1byte** 718 +|(% style="width:58px" %)31|(% style="width:127px" %)Timestamp start|(% style="width:124px" %)Timestamp end|(% style="width:114px" %)Uplink Interval 719 + 720 +((( 721 +Timestamp start and Timestamp end-use Unix TimeStamp format as mentioned above. Devices will reply with all data logs during this period, using the uplink interval. 722 +))) 723 + 724 +((( 725 +For example, downlink command[[image:image-20220518162852-1.png]] 726 +))) 727 + 728 +((( 729 +Is to check 2021/11/12 12:00:00 to 2021/11/12 15:00:00's data 730 +))) 731 + 732 +((( 733 +Uplink Internal =5s,means CPL01 will send one packet every 5s. range 5~~255s. 734 +))) 735 + 736 + 552 552 == 2.7 Frequency Plans == 553 553 554 554 ... ... @@ -568,6 +568,8 @@ 568 568 * AT Command via UART Connection : See [[UART Connection>>http://wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H2.3UARTConnectionforSN50v3basemotherboard]]. 569 569 * LoRaWAN Downlink. Instruction for different platforms: See [[IoT LoRaWAN Server>>http://wiki.dragino.com/xwiki/bin/view/Main/]] section. 570 570 756 + 757 + 571 571 == 3.2 General Commands == 572 572 573 573 ... ... @@ -581,21 +581,25 @@ 581 581 [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/>>http://wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/]] 582 582 583 583 584 -== 3.3 Commands special design for S31x-LB ==771 +== 3.3 Commands special design for CPL03-LB == 585 585 586 586 587 -These commands only valid for S31x-LB, as below:774 +These commands only valid for CPL03-LB, as below: 588 588 589 589 590 590 === 3.3.1 Set Transmit Interval Time === 591 591 592 592 780 +((( 593 593 Feature: Change LoRaWAN End Node Transmit Interval. 782 +))) 594 594 784 +((( 595 595 (% style="color:blue" %)**AT Command: AT+TDC** 786 +))) 596 596 597 597 (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %) 598 -|=(% style="width: 156px;background-color:#D9E2F3" %)**Command Example**|=(% style="width: 137px;background-color:#D9E2F3" %)**Function**|=(% style="background-color:#D9E2F3" %)**Response** 789 +|=(% style="width: 156px;background-color:#D9E2F3; color:#0070c0" %)**Command Example**|=(% style="width: 137px;background-color:#D9E2F3; color:#0070c0" %)**Function**|=(% style="background-color:#D9E2F3; color:#0070c0" %)**Response** 599 599 |(% style="width:156px" %)AT+TDC=?|(% style="width:137px" %)Show current transmit Interval|((( 600 600 30000 601 601 OK ... ... @@ -606,18 +606,47 @@ 606 606 Set transmit interval to 60000ms = 60 seconds 607 607 ))) 608 608 800 +((( 609 609 (% style="color:blue" %)**Downlink Command: 0x01** 802 +))) 610 610 804 +((( 611 611 Format: Command Code (0x01) followed by 3 bytes time value. 806 +))) 612 612 808 +((( 613 613 If the downlink payload=0100003C, it means set the END Node's Transmit Interval to 0x00003C=60(S), while type code is 01. 810 +))) 614 614 615 -* Example 1: Downlink Payload: 0100001E ~/~/ Set Transmit Interval (TDC) = 30 seconds 616 -* Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds 812 +* ((( 813 +Example 1: Downlink Payload: 0100001E ~/~/ Set Transmit Interval (TDC) = 30 seconds 814 +))) 815 +* ((( 816 +Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds 617 617 618 -=== 3.3.2 Get Device Status === 619 619 819 + 820 +))) 620 620 822 +=== 3.3.2 Quit AT Command === 823 + 824 + 825 +Feature: Quit AT Command mode, so user needs to input the password again before using AT Commands. 826 + 827 +(% style="color:blue" %)**AT Command: AT+DISAT** 828 + 829 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:452px" %) 830 +|=(% style="width: 155px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 198px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 99px;background-color:#D9E2F3;color:#0070C0" %)**Response** 831 +|(% style="width:155px" %)AT+DISAT|(% style="width:198px" %)Quit AT Commands mode|(% style="width:96px" %)OK 832 + 833 +(% style="color:blue" %)**Downlink Command:** 834 + 835 +No downlink command for this feature. 836 + 837 + 838 +=== 3.3.3 Get Device Status === 839 + 840 + 621 621 Send a LoRaWAN downlink to ask device send Alarm settings. 622 622 623 623 (% style="color:blue" %)**Downlink Payload: **(%%)0x26 01 ... ... @@ -625,82 +625,197 @@ 625 625 Sensor will upload Device Status via FPORT=5. See payload section for detail. 626 626 627 627 628 -=== 3.3. 3SetTemperature AlarmThreshold===848 +=== 3.3.4 Enable / Disable Alarm === 629 629 630 630 631 - *(%style="color:blue"%)**ATCommand:**851 +Feature: Enable/Disable Alarm for open/close event. Default value 0. 632 632 633 -(% style="color: #037691" %)**AT+SHTEMP=min,max**853 +(% style="color:blue" %)**AT Command:** 634 634 635 -* When min=0, and max≠0, Alarm higher than max 636 -* When min≠0, and max=0, Alarm lower than min 637 -* When min≠0 and max≠0, Alarm higher than max or lower than min 855 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:520px" %) 856 +|(% style="background-color:#d9e2f3; color:#0070c0; width:154px" %)**Command Example**|(% style="background-color:#d9e2f3; color:#0070c0; width:278px" %)**Function**|(% style="background-color:#d9e2f3; color:#0070c0; width:88px" %)**Response** 857 +|(% style="width:154px" %)AT+DISALARM=1|(% style="width:278px" %)End node will only send packets in TDC time.|OK 858 +|(% style="width:154px" %)AT+DISALARM=0|(% style="width:278px" %)End node will send packets in TDC time or status change for door sensor|OK 638 638 639 - Example:860 +(% style="color:blue" %)**Downlink Command:** 640 640 641 - T+SHTEMP=0,30Alarmwhentemperaturehigher than 30.862 +**0xA7 01** ~/~/ Same As AT+DISALARM=1 642 642 643 -* (%style="color:blue" %)**DownlinkPayload:**864 +**0xA7 00 ** ~/~/ Same As AT+DISALARM=0 644 644 645 -(% style="color:#037691" %)**0x(0C 01 00 1E)** (%%) ~/~/ Set AT+SHTEMP=0,30 646 646 647 - (% style="color:red"%)**(note:3^^rd^^byte= 0x00 forlow limit(notset),4^^th^^ byte = 0x1E forhigh limit:30)**867 +=== 3.3.5 Alarm Base on Timeout === 648 648 649 649 650 -=== 3.3.4 Set Humidity Alarm Threshold === 870 +((( 871 +CPL03-LB can monitor the timeout for a status change, this feature can be used to monitor some events such as door opening too long etc. Related Parameters are: 872 +))) 651 651 652 652 653 -* (% style="color:blue" %)**AT Command:** 875 +((( 876 +(% style="color:#4f81bd" %)**1. Keep Status: Status to be monitor** 877 +))) 654 654 655 -(% style="color:#037691" %)**AT+SHHUM=min,max** 879 +((( 880 +**Keep Status = 1**: Monitor Close to Open event 881 +))) 656 656 657 - * When min=0, and max≠0, Alarm higher than max658 -* Whenmin≠0,andmax=0,Alarmlowerthanmin659 - * When min≠0 and max≠0, Alarm higher than max or lower than min883 +((( 884 +**Keep Status = 0**: Monitor Open to Close event 885 +))) 660 660 661 -Example: 662 662 663 - AT+SHHUM=70,0 ~/~/ Alarm when humidity lower than 70%. 888 +((( 889 +(% style="color:#4f81bd" %)**2. Keep Time: Timeout to send an Alarm** 890 +))) 664 664 665 -* (% style="color:blue" %)**Downlink Payload:** 892 +((( 893 +Range 0 ~~ 65535(0xFFFF) seconds. 894 +))) 666 666 667 -(% style="color:#037691" %)**0x(0C 02 46 00)**(%%) ~/~/ Set AT+SHTHUM=70,0 896 +((( 897 +If** keep time = 0**, Disable Alarm Base on Timeout feature. 898 +))) 668 668 669 -(% style="color:red" %)**(note: 3^^rd^^ byte= 0x46 for low limit (70%), 4^^th^^ byte = 0x00 for high limit (not set))** 900 +((( 901 +If **keep time > 0**, device will monitor the keep status event and send an alarm when status doesn’t change after timeout. 902 +))) 670 670 671 671 672 -=== 3.3.5 Set Alarm Interval === 905 +((( 906 +(% style="color:#4f81bd" %)**AT Command**(%%) to configure: 907 +))) 673 673 909 +((( 910 +(% style="color:blue" %)**AT+TTRIG=1,30**(%%) ~-~-> When the **Keep Status** change from connect to disconnect, and device remains in disconnect status for more than 30 seconds. CPL01 will send an uplink packet, the [[Alarm bit>>||anchor="H2.3.3Real-TimeOpen2FCloseStatus2CUplinkFPORT3D2"]] (the second bit of 1^^st^^ byte of payload) on this uplink packet is set to 1. 911 +))) 674 674 675 -The shortest time of two Alarm packet. (unit: min) 913 +((( 914 +(% style="color:blue" %)**AT+TTIG=0,0 **(%%) ~-~-> Default Value, disable timeout Alarm. 915 +))) 676 676 677 -* (% style="color:blue" %)**AT Command:** 678 678 679 -(% style="color:#037691" %)**AT+ATDC=30** (%%) ~/~/ The shortest interval of two Alarm packets is 30 minutes, Means is there is an alarm packet uplink, there won't be another one in the next 30 minutes. 918 +((( 919 +(% style="color:#4f81bd" %)**Downlink Command**(%%) to configure: 920 +))) 680 680 681 -* (% style="color:blue" %)**Downlink Payload:** 922 +((( 923 +**Command: 0xA9 aa bb cc** 924 +))) 682 682 683 -(% style="color:#037691" %)**0x(0D 00 1E)**(%%) **~-~--> ** Set AT+ATDC=0x 00 1E = 30 minutes 926 +((( 927 +**A9: **Command Type Code 928 +))) 684 684 930 +((( 931 +**aa: **status to be monitored 932 +))) 685 685 686 -=== 3.3.6 Get Alarm settings === 934 +((( 935 +**bb cc: **timeout. 936 +))) 687 687 688 688 689 -Send a LoRaWAN downlink to ask device send Alarm settings. 939 +((( 940 +If user send 0xA9 01 00 1E: equal to AT+TTRIG=1,30 941 +))) 690 690 691 -* (% style="color:#037691" %)**Downlink Payload: **(%%)0x0E 01 943 +((( 944 +Or 945 +))) 692 692 693 -**Example:** 947 +((( 948 +0xA9 00 00 00: Equal to AT+TTRIG=0,0. Disable timeout Alarm. 949 +))) 694 694 695 -[[image:image-20230524110211-4.png]] 696 696 697 - **Explain:**952 +=== 3.3.6 Clear Flash Record === 698 698 699 -* Alarm & MOD bit is 0x7C, 0x7C >> 2 = 0x31: Means this message is the Alarm settings message. 700 700 701 - === 3.3.7 SetInterruptMode===955 +Feature: Clear flash storage for data log feature. 702 702 957 +(% style="color:blue" %)**AT Command: AT+CLRDTA** 703 703 959 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:500px" %) 960 +|=(% style="width: 157px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 169px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 174px;background-color:#D9E2F3;color:#0070C0" %)**Response** 961 +|(% style="width:157px" %)AT+CLRDTA|(% style="width:169px" %)Clear flash storage for data log feature.|Clear all stored sensor data… OK 962 + 963 +((( 964 +(% style="color:blue" %)**Downlink Command:** 965 +))) 966 + 967 +((( 968 +* **Example**: 0xA301 ~/~/ Same as AT+CLRDTA 969 +))) 970 + 971 + 972 + 973 + 974 +=== 3.3.7 Set trigger mode === 975 + 976 + 977 +Feature: Set the trigger interrupt mode. 978 + 979 +(% style="color:blue" %)**AT Command: AT+TTRMOD** 980 + 981 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:495px" %) 982 +|=(% style="width: 157px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 246px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 92px;background-color:#D9E2F3;color:#0070C0" %)**Response** 983 +|(% style="width:157px" %)((( 984 +AT+TTRMOD=1 985 +)))|(% style="width:156px" %)Count and trigger from open to close (rising edge)|(% style="width:89px" %)((( 986 +((( 987 +OK 988 +))) 989 +))) 990 +|(% style="width:157px" %)((( 991 +AT+TTRMOD=0 992 +)))|(% style="width:156px" %)Count and trigger from close to open (falling edge)|(% style="width:89px" %)((( 993 +OK 994 +))) 995 + 996 +(% style="color:blue" %)**Downlink Command:** 997 + 998 +* **Example**: 0xA401 ~/~/ Same as AT+ TTRMOD =1 999 + 1000 + 1001 + 1002 +=== 3.3.8 Set the calculate flag === 1003 + 1004 + 1005 +Feature: Set the calculate flag 1006 + 1007 +(% style="color:blue" %)**AT Command: AT+CALCFLAG** 1008 + 1009 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:461px" %) 1010 +|=(% style="width: 158px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 193px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 110px;background-color:#D9E2F3;color:#0070C0" %)**Response** 1011 +|(% style="width:158px" %)AT+CALCFLAG =1|(% style="width:192px" %)Set the calculate flag to 1.|(% style="width:109px" %)OK 1012 +|(% style="width:158px" %)AT+CALCFLAG =2|(% style="width:192px" %)Set the calculate flag to 2.|(% style="width:109px" %)OK 1013 + 1014 +(% style="color:blue" %)**Downlink Command:** 1015 + 1016 +* **Example**: 0XA501 ~/~/ Same as AT+CALCFLAG =1 1017 + 1018 +=== 3.3.9 Set count number === 1019 + 1020 + 1021 +Feature: Manually set the count number 1022 + 1023 +(% style="color:blue" %)**AT Command: AT+SETCNT** 1024 + 1025 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:479px" %) 1026 +|=(% style="width: 160px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 223px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 96px;background-color:#D9E2F3;color:#0070C0" %)**Response** 1027 +|(% style="width:160px" %)AT+ SETCNT =0|(% style="width:221px" %)Set the count number to 0.|(% style="width:95px" %)OK 1028 +|(% style="width:160px" %)AT+ SETCNT =100|(% style="width:221px" %)Set the count number to 100.|(% style="width:95px" %)OK 1029 + 1030 +(% style="color:blue" %)**Downlink Command:** 1031 + 1032 +* **Example**: 0xA6000001 ~/~/ Same as AT+ SETCNT =1 1033 + 1034 +* **Example**: 0xA6000064 ~/~/ Same as AT+ SETCNT =100 1035 + 1036 +=== 3.3.10 Set Interrupt Mode === 1037 + 1038 + 704 704 Feature, Set Interrupt mode for PA8 of pin. 705 705 706 706 When AT+INTMOD=0 is set, PA8 is used as a digital input port. ... ... @@ -708,7 +708,7 @@ 708 708 (% style="color:blue" %)**AT Command: AT+INTMOD** 709 709 710 710 (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %) 711 -|=(% style="width: 15 4px;background-color:#D9E2F3" %)**Command Example**|=(% style="width: 196px;background-color:#D9E2F3" %)**Function**|=(% style="width: 157px;background-color:#D9E2F3" %)**Response**1046 +|=(% style="width: 155px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 197px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 158px;background-color:#D9E2F3;color:#0070C0" %)**Response** 712 712 |(% style="width:154px" %)AT+INTMOD=?|(% style="width:196px" %)Show current interrupt mode|(% style="width:157px" %)((( 713 713 0 714 714 OK ... ... @@ -729,11 +729,14 @@ 729 729 This means that the interrupt mode of the end node is set to 0x000003=3 (rising edge trigger), and the type code is 06. 730 730 731 731 * Example 1: Downlink Payload: 06000000 ~/~/ Turn off interrupt mode 1067 + 732 732 * Example 2: Downlink Payload: 06000003 ~/~/ Set the interrupt mode to rising edge trigger 733 733 734 -=== 3.3.8 Set Power Output Duration === 735 735 736 736 1072 +=== 3.3.11 Set Power Output Duration === 1073 + 1074 + 737 737 Control the output duration 5V . Before each sampling, device will 738 738 739 739 ~1. first enable the power output to external sensor, ... ... @@ -745,7 +745,7 @@ 745 745 (% style="color:blue" %)**AT Command: AT+5VT** 746 746 747 747 (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %) 748 -|=(% style="width: 15 4px;background-color:#D9E2F3" %)**Command Example**|=(% style="width: 196px;background-color:#D9E2F3" %)**Function**|=(% style="width: 157px;background-color:#D9E2F3" %)**Response**1086 +|=(% style="width: 155px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 197px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 158px;background-color:#D9E2F3;color:#0070C0" %)**Response** 749 749 |(% style="width:154px" %)AT+5VT=?|(% style="width:196px" %)Show 5V open time.|(% style="width:157px" %)0 (default) 750 750 OK 751 751 |(% style="width:154px" %)AT+5VT=500|(% style="width:196px" %)Close after a delay of 1000 milliseconds.|(% style="width:157px" %)OK ... ... @@ -757,12 +757,15 @@ 757 757 The first and second bytes are the time to turn on. 758 758 759 759 * Example 1: Downlink Payload: 070000 **~-~-->** AT+5VT=0 1098 + 760 760 * Example 2: Downlink Payload: 0701F4 **~-~-->** AT+5VT=500 761 761 1101 + 1102 + 762 762 = 4. Battery & Power Consumption = 763 763 764 764 765 - S31x-LB use ER26500 + SPC1520 battery pack. See below link for detail information about the battery info and how to replace.1106 +CPL03-LB use ER26500 + SPC1520 battery pack. See below link for detail information about the battery info and how to replace. 766 766 767 767 [[**Battery Info & Power Consumption Analyze**>>http://wiki.dragino.com/xwiki/bin/view/Main/How%20to%20calculate%20the%20battery%20life%20of%20Dragino%20sensors%3F/]] . 768 768 ... ... @@ -771,10 +771,12 @@ 771 771 772 772 773 773 (% class="wikigeneratedid" %) 774 -User can change firmware S31x-LB to:1115 +User can change firmware CPL03-LB to: 775 775 776 776 * Change Frequency band/ region. 1118 + 777 777 * Update with new features. 1120 + 778 778 * Fix bugs. 779 779 780 780 Firmware and changelog can be downloaded from : **[[Firmware download link>>url:https://www.dropbox.com/sh/kwqv57tp6pejias/AAAopYMATh1GM6fZ-VRCLrpDa?dl=0]]** ... ... @@ -783,18 +783,23 @@ 783 783 Methods to Update Firmware: 784 784 785 785 * (Recommanded way) OTA firmware update via wireless: [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/Firmware%20OTA%20Update%20for%20Sensors/>>url:http://wiki.dragino.com/xwiki/bin/view/Main/Firmware%20OTA%20Update%20for%20Sensors/]] 1129 + 786 786 * Update through UART TTL interface. **[[Instruction>>url:http://wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H1.LoRaSTv4baseHardware]]**. 787 787 788 788 = 6. FAQ = 789 789 1134 +== 6.1 AT Commands input doesn't work == 790 790 791 791 1137 +In the case if user can see the console output but can't type input to the device. Please check if you already include the (% style="color:green" %)**ENTER**(%%) while sending out the command. Some serial tool doesn't send (% style="color:green" %)**ENTER**(%%) while press the send key, user need to add ENTER in their string. 1138 + 1139 + 792 792 = 7. Order Info = 793 793 794 794 795 -Part Number: (% style="color:blue" %)** S31-LB-XX / S31B-LB-XX**1143 +Part Number: (% style="color:blue" %)**CPL03-LB-XXX** 796 796 797 -(% style="color:red" %)**XX**(%%): The default frequency band 1145 +(% style="color:red" %)**XXX**(%%): The default frequency band 798 798 799 799 * (% style="color:red" %)**AS923**(%%): LoRaWAN AS923 band 800 800 ... ... @@ -817,7 +817,7 @@ 817 817 818 818 (% style="color:#037691" %)**Package Includes**: 819 819 820 -* S31x-LB LoRaWANTemperature& HumiditySensor1168 +* CPL03-LB LoRaWAN Pulse/Contact Sensor 821 821 822 822 (% style="color:#037691" %)**Dimension and weight**: 823 823
- image-20230530084138-1.jpeg
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +1.1 MB - Content
- image-20230530084608-2.jpeg
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +1.1 MB - Content