Changes for page DS20L -- LoRaWAN Smart Distance Detector User Manual 01
Last modified by Mengting Qiu on 2023/12/14 11:15
Summary
-
Page properties (3 modified, 0 added, 0 removed)
-
Attachments (0 modified, 13 added, 0 removed)
- image-20230524144456-2.png
- image-20230527093155-1.jpeg
- image-20230527093214-2.jpeg
- image-20230530084138-1.jpeg
- image-20230530084608-2.jpeg
- image-20230530111051-3.png
- image-20230530111412-4.png
- image-20230530135919-1.png
- image-20230530135929-2.png
- image-20230530140053-1.jpeg
- image-20230612170349-1.png
- image-20230612170943-2.png
- image-20230612171032-3.png
Details
- Page properties
-
- Title
-
... ... @@ -1,1 +1,1 @@ 1 -S 31-LB/ S31B-LBLoRaWANOutdoorTemperature& HumiditySensor User Manual1 +DDS75-LB -- LoRaWAN Distance Detection Sensor User Manual - Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Saxer1 +XWiki.Xiaoling - Content
-
... ... @@ -1,5 +1,5 @@ 1 1 (% style="text-align:center" %) 2 -[[image: S31-B.jpg]]2 +[[image:image-20230612170349-1.png||height="656" width="656"]] 3 3 4 4 5 5 ... ... @@ -15,22 +15,22 @@ 15 15 16 16 = 1. Introduction = 17 17 18 -== 1.1 What is S31x-LB LoRaWANTemperature& HumiditySensor ==18 +== 1.1 What is LoRaWAN Distance Detection Sensor == 19 19 20 20 21 -The Dragino S 31x-LB is a (% style="color:blue" %)**LoRaWANTemperatureandHumiditySensor**(%%) for Internet of Things solution. It is used to measure the (% style="color:blue" %)**surrounding environment temperature andrelative airhumidityprecisely**(%%), andthenupload toIoTserver viaLoRaWANwirelessprotocol.21 +The Dragino DDS75-LB is a (% style="color:blue" %)** LoRaWAN Distance Detection Sensor**(%%) for Internet of Things solution. It is used to measure the distance between the sensor and a flat object. The distance detection sensor is a module that uses (% style="color:blue" %)** ultrasonic sensing technology**(%%) for (% style="color:blue" %)**distance measurement**(%%), and (% style="color:blue" %)** temperature compensation**(%%) is performed internally to improve the reliability of data. The DDS75-LB can be applied to scenarios such as horizontal distance measurement, liquid level measurement, parking management system, object proximity and presence detection, intelligent trash can management system, robot obstacle avoidance, automatic control, sewer, bottom water level monitoring, etc. 22 22 23 - Thetemperature& humiditysensorusedin S31x-LB isSHT31, whichisfullyalibrated,linearized, andtemperaturecompensateddigitaloutputfrom Sensirion,it providesastrongreliability andlong-termstability. TheSHT31isfixed in a (% style="color:blue"%)**waterproofanti-condensationcasing**(%%) forlong term use.23 +It detects the distance(% style="color:blue" %)** between the measured object and the sensor**(%%), and uploads the value via wireless to LoRaWAN IoT Server. 24 24 25 -The LoRa wireless technology used in S3 1x-LB allows device to send data and reach extremely long ranges at low data-rates. It provides ultra-long range spread spectrum communication and high interference immunity whilst minimizing current consumption.25 +The LoRa wireless technology used in SW3L-LB allows device to send data and reach extremely long ranges at low data-rates. It provides ultra-long range spread spectrum communication and high interference immunity whilst minimizing current consumption. 26 26 27 -S3 1x-LBsupports(% style="color:blue" %)**Temperature&Humdity alarmfeature**(%%),user can settemperaturealarm forinstantnotice.S31x-LB supports Datalog feature,itcan save thedata whenthereisno LoRaWAN networkanduplink when network recover.27 +SW3L-LB (% style="color:blue" %)**supports BLE configure**(%%) and (% style="color:blue" %)**wireless OTA update**(%%) which make user easy to use. 28 28 29 -S3 1x-LB(%style="color:blue"%)**supports BLE configure**(%%) and (% style="color:blue" %)**wirelessOTAupdate**(%%)whichmakeuser easytouse.29 +SW3L-LB is powered by (% style="color:blue" %)**8500mAh Li-SOCI2 battery**(%%), it is designed for long term use up to 5 years. 30 30 31 -S3 1x-LB is poweredby (%style="color:blue"%)**8500mAhLi-SOCI2battery**(%%), itisdesignedforlongtermuseupto5years.31 +Each SW3L-LB is pre-load with a set of unique keys for LoRaWAN registrations, register these keys to local LoRaWAN server and it will auto connect after power on. 32 32 33 - Each S31x-LBis pre-load with a set of unique keys for LoRaWAN registrations, register these keys to local LoRaWAN server andit will auto connect after power on.33 +[[image:image-20230612170943-2.png||height="525" width="912"]] 34 34 35 35 36 36 == 1.2 Features == ... ... @@ -37,39 +37,54 @@ 37 37 38 38 39 39 * LoRaWAN 1.0.3 Class A 40 -* Ultra-low power consumption 41 -* External 3 meters SHT31 probe (For S31-LB) 42 -* Measure range -55°C ~~ 125°C 43 -* Temperature & Humidity alarm 44 44 * Bands: CN470/EU433/KR920/US915/EU868/AS923/AU915/IN865 41 +* Ultra-low power consumption 42 +* Distance Detection by Ultrasonic technology 43 +* Flat object range 280mm - 7500mm 44 +* Accuracy: ±(1cm+S*0.3%) (S: Distance) 45 +* Cable Length : 25cm 45 45 * Support Bluetooth v5.1 and LoRaWAN remote configure 46 46 * Support wireless OTA update firmware 47 -* Uplinkon periodically48 +* AT Commands to change parameters 48 48 * Downlink to change configure 50 +* IP66 Waterproof Enclosure 49 49 * 8500mAh Battery for long term use 50 50 51 51 == 1.3 Specification == 52 52 53 53 54 -(% style="color:#037691" %)** CommonDC Characteristics:**56 +(% style="color:#037691" %)**Rated environmental conditions:** 55 55 56 -* Supply Voltage: built in 8500mAh Li-SOCI2 battery , 2.5v ~~ 3.6v 57 -* Operating Temperature: -40 ~~ 85°C 58 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:500px" %) 59 +|(% style="background-color:#d9e2f3; color:#0070c0; width:163px" %)**Item**|(% style="background-color:#d9e2f3; color:#0070c0; width:90px" %)((( 60 +**Minimum value** 61 +)))|(% style="background-color:#d9e2f3; color:#0070c0; width:70px" %)((( 62 +**Typical value** 63 +)))|(% style="background-color:#d9e2f3; color:#0070c0; width:87px" %)((( 64 +**Maximum value** 65 +)))|(% style="background-color:#d9e2f3; color:#0070c0; width:40px" %)**Unit**|(% style="background-color:#d9e2f3; color:#0070c0; width:50px" %)**Remarks** 66 +|(% style="width:174px" %)Storage temperature|(% style="width:86px" %)-25|(% style="width:66px" %)25|(% style="width:90px" %)80|(% style="width:48px" %)℃|(% style="width:203px" %) 67 +|(% style="width:174px" %)Storage humidity|(% style="width:86px" %) |(% style="width:66px" %)65%|(% style="width:90px" %)90%|(% style="width:48px" %)RH|(% style="width:203px" %)(1) 68 +|(% style="width:174px" %)Operating temperature|(% style="width:86px" %)-15|(% style="width:66px" %)25|(% style="width:90px" %)60|(% style="width:48px" %)℃|(% style="width:203px" %) 69 +|(% style="width:174px" %)Working humidity|(% style="width:86px" %)((( 70 + 58 58 59 -(% style="color:#037691" %)**Temperature Sensor:** 72 + 73 +)))|(% style="width:66px" %)65%|(% style="width:90px" %)80%|(% style="width:48px" %)RH|(% style="width:203px" %)(1) 60 60 61 -* Range: -40 to + 80°C 62 -* Accuracy: ±0.2 @ 0-90 °C 63 -* Resolution: 0.1°C 64 -* Long Term Shift: <0.03 °C/yr 75 +((( 76 +**Remarks: (1) a. When the ambient temperature is 0-39 ℃, the maximum humidity is 90% (non-condensing); ** 65 65 66 - (%style="color:#037691"%)**HumiditySensor:**78 +**~ b. When the ambient temperature is 40-50 ℃, the highest humidity is the highest humidity in the natural world at the current temperature (no condensation)** 67 67 68 -* Range: 0 ~~ 99.9% RH 69 -* Accuracy: ± 2%RH ( 0 ~~ 100%RH) 70 -* Resolution: 0.01% RH 71 -* Long Term Shift: <0.25 %RH/yr 80 + 81 +))) 72 72 83 +(% style="color:#037691" %)**Common DC Characteristics:** 84 + 85 +* Supply Voltage: built in 8500mAh Li-SOCI2 battery , 2.5v ~~ 3.6v 86 +* Operating Temperature: -40 ~~ 85°C 87 + 73 73 (% style="color:#037691" %)**LoRa Spec:** 74 74 75 75 * Frequency Range, Band 1 (HF): 862 ~~ 1020 Mhz ... ... @@ -90,15 +90,41 @@ 90 90 * Sleep Mode: 5uA @ 3.3v 91 91 * LoRa Transmit Mode: 125mA @ 20dBm, 82mA @ 14dBm 92 92 93 -== 1.4 Sleepmodedworking mode ==108 +== 1.4 Effective measurement range Reference beam pattern == 94 94 95 95 111 +**~1. The tested object is a white cylindrical tube made of PVC, with a height of 100cm and a diameter of 7.5cm.** 112 + 113 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDDS75%20-%20LoRaWAN%20Distance%20Detection%20Sensor%20User%20Manual/WebHome/1654852253176-749.png?rev=1.1||alt="1654852253176-749.png"]] 114 + 115 + 116 +**2. The object to be tested is a "corrugated cardboard box" perpendicular to the central axis of 0 °, and the length * width is 60cm * 50cm.** 117 + 118 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDDS75%20-%20LoRaWAN%20Distance%20Detection%20Sensor%20User%20Manual/WebHome/1654852175653-550.png?rev=1.1||alt="1654852175653-550.png"]] 119 + 120 + 121 +== 1.5 Applications == 122 + 123 + 124 +* Horizontal distance measurement 125 +* Liquid level measurement 126 +* Parking management system 127 +* Object proximity and presence detection 128 +* Intelligent trash can management system 129 +* Robot obstacle avoidance 130 +* Automatic control 131 +* Sewer 132 +* Bottom water level monitoring 133 + 134 +== 1.6 Sleep mode and working mode == 135 + 136 + 96 96 (% style="color:blue" %)**Deep Sleep Mode: **(%%)Sensor doesn't have any LoRaWAN activate. This mode is used for storage and shipping to save battery life. 97 97 98 98 (% style="color:blue" %)**Working Mode:** (%%)In this mode, Sensor will work as LoRaWAN Sensor to Join LoRaWAN network and send out sensor data to server. Between each sampling/tx/rx periodically, sensor will be in IDLE mode), in IDLE mode, sensor has the same power consumption as Deep Sleep mode. 99 99 100 100 101 -== 1. 5Button & LEDs ==142 +== 1.7 Button & LEDs == 102 102 103 103 104 104 [[image:Main.User Manual for LoRaWAN End Nodes.D20-LBD22-LBD23-LB_LoRaWAN_Temperature_Sensor_User_Manual.WebHome@1675071855856-879.png]] ... ... @@ -117,10 +117,10 @@ 117 117 ))) 118 118 |(% style="width:167px" %)Fast press ACT 5 times.|(% style="width:117px" %)Deactivate Device|(% style="width:225px" %)(% style="color:red" %)**Red led**(%%) will solid on for 5 seconds. Means device is in Deep Sleep Mode. 119 119 120 -== 1. 6BLE connection ==161 +== 1.8 BLE connection == 121 121 122 122 123 -S 31x-LB support BLE remote configure.164 +DDS75-LB support BLE remote configure. 124 124 125 125 126 126 BLE can be used to configure the parameter of sensor or see the console output from sensor. BLE will be only activate on below case: ... ... @@ -132,56 +132,45 @@ 132 132 If there is no activity connection on BLE in 60 seconds, sensor will shut down BLE module to enter low power mode. 133 133 134 134 135 -== 1. 7Pin Definitions ==176 +== 1.9 Pin Definitions == 136 136 137 137 [[image:image-20230523174230-1.png]] 138 138 139 139 140 -== 1.8HardwareVariant==181 +== == 141 141 183 +== 2.10 Mechanical == 142 142 143 -(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:510px" %) 144 -|=(% style="width: 102px;background-color:#D9E2F3;color:#0070C0" %)Model|=(% style="width: 190px;background-color:#D9E2F3;color:#0070C0" %)Photo|=(% style="width: 218px;background-color:#D9E2F3;color:#0070C0" %)Probe Info 145 -|(% style="width:102px" %)((( 146 -S31-LB 147 -)))|(% style="width:190px" %)[[image:S31.jpg]]|(% style="width:297px" %)((( 148 -1 x SHT31 Probe 149 149 150 - CableLength:2meters186 +[[image:Main.User Manual for LoRaWAN End Nodes.D20-LBD22-LBD23-LB_LoRaWAN_Temperature_Sensor_User_Manual.WebHome@1675143884058-338.png]] 151 151 152 - 153 -))) 154 -|(% style="width:102px" %)((( 155 -S31B-LB 156 -)))|(% style="width:190px" %)[[image:S31B.jpg]]|(% style="width:297px" %)((( 157 -1 x SHT31 Probe 158 158 159 -Installed in device. 160 -))) 189 +[[image:Main.User Manual for LoRaWAN End Nodes.D20-LBD22-LBD23-LB_LoRaWAN_Temperature_Sensor_User_Manual.WebHome@1675143899218-599.png]] 161 161 162 -(% style="display:none" %) 163 163 192 +[[image:Main.User Manual for LoRaWAN End Nodes.D20-LBD22-LBD23-LB_LoRaWAN_Temperature_Sensor_User_Manual.WebHome@1675143909447-639.png]] 164 164 165 165 166 - ==1.9Mechanical==195 +**Probe Mechanical:** 167 167 168 168 169 -[[image: Main.User.D20-LBD22-LBD23-LB_LoRaWAN_Temperature_Sensor_User_Manual.WebHome@1675143884058-338.png]]198 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDDS75%20-%20LoRaWAN%20Distance%20Detection%20Sensor%20User%20Manual/WebHome/image-20220610172003-1.png?rev=1.1||alt="image-20220610172003-1.png"]] 170 170 171 171 172 -[[image: Main.User.D20-LBD22-LBD23-LB_LoRaWAN_Temperature_Sensor_User_Manual.WebHome@1675143899218-599.png]]201 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDDS75%20-%20LoRaWAN%20Distance%20Detection%20Sensor%20User%20Manual/WebHome/image-20220610172003-2.png?rev=1.1||alt="image-20220610172003-2.png"]] 173 173 174 174 175 -[[image: Main.User.D20-LBD22-LBD23-LB_LoRaWAN_Temperature_Sensor_User_Manual.WebHome@1675143909447-639.png]]204 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDDS75%20-%20LoRaWAN%20Distance%20Detection%20Sensor%20User%20Manual/WebHome/image-20220610172003-2.png?rev=1.1||alt="image-20220610172003-2.png"]] 176 176 177 177 178 -= 2. Configure S 31x-LB to connect to LoRaWAN network =207 += 2. Configure DDS75-LB to connect to LoRaWAN network = 179 179 180 180 == 2.1 How it works == 181 181 182 182 183 -The S 31x-LB is configured as (% style="color:#037691" %)**LoRaWAN OTAA Class A**(%%) mode by default. It has OTAA keys to join LoRaWAN network. To connect a local LoRaWAN network, you need to input the OTAA keys in the LoRaWAN IoT server and press the button to activate the S31x-LB. It will automatically join the network via OTAA and start to send the sensor value. The default uplink interval is 20 minutes.212 +The DDS75-LB is configured as (% style="color:#037691" %)**LoRaWAN OTAA Class A**(%%) mode by default. It has OTAA keys to join LoRaWAN network. To connect a local LoRaWAN network, you need to input the OTAA keys in the LoRaWAN IoT server and press the button to activate the DDS75-LB. It will automatically join the network via OTAA and start to send the sensor value. The default uplink interval is 20 minutes. 184 184 214 +(% style="display:none" %) (%%) 185 185 186 186 == 2.2 Quick guide to connect to LoRaWAN server (OTAA) == 187 187 ... ... @@ -188,13 +188,15 @@ 188 188 189 189 Following is an example for how to join the [[TTN v3 LoRaWAN Network>>url:https://console.cloud.thethings.network/]]. Below is the network structure; we use the [[LPS8v2>>url:https://www.dragino.com/products/lora-lorawan-gateway/item/228-lps8v2.html]] as a LoRaWAN gateway in this example. 190 190 191 -The LPS8 V2 is already set to connected to [[TTN network >>url:https://console.cloud.thethings.network/]], so what we need to now is configure the TTN server.221 +The LPS8v2 is already set to connected to [[TTN network >>url:https://console.cloud.thethings.network/]], so what we need to now is configure the TTN server. 192 192 223 +[[image:image-20230612171032-3.png||height="492" width="855"]](% style="display:none" %) 193 193 194 -(% style="color:blue" %)**Step 1:**(%%) Create a device in TTN with the OTAA keys from S31x-LB. 195 195 196 - EachS31x-LBis shipped withastickerwith thedefaultdevice EUI asbelow:226 +(% style="color:blue" %)**Step 1:**(%%) Create a device in TTN with the OTAA keys from DDS75-LB. 197 197 228 +Each DDS75-LB is shipped with a sticker with the default device EUI as below: 229 + 198 198 [[image:image-20230426084152-1.png||alt="图片-20230426084152-1.png" height="233" width="502"]] 199 199 200 200 ... ... @@ -222,10 +222,10 @@ 222 222 [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LSN50v2-S31-S31B%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20User%20Manual/WebHome/image-20220611161308-6.png?width=744&height=485&rev=1.1||alt="图片-20220611161308-6.png"]] 223 223 224 224 225 -(% style="color:blue" %)**Step 2:**(%%) Activate on S 31x-LB257 +(% style="color:blue" %)**Step 2:**(%%) Activate on DDS75-LB 226 226 227 227 228 -Press the button for 5 seconds to activate the S 31x-LB.260 +Press the button for 5 seconds to activate the DDS75-LB. 229 229 230 230 (% style="color:green" %)**Green led**(%%) will fast blink 5 times, device will enter (% style="color:blue" %)**OTA mode**(%%) for 3 seconds. And then start to JOIN LoRaWAN network. (% style="color:green" %)**Green led**(%%) will solidly turn on for 5 seconds after joined in network. 231 231 ... ... @@ -232,177 +232,178 @@ 232 232 After join success, it will start to upload messages to TTN and you can see the messages in the panel. 233 233 234 234 235 -== 2.3 Uplink Payload == 267 +== 2.3 Uplink Payload == 236 236 237 -=== 2.3.1 Device Status, FPORT~=5 === 238 238 270 +((( 271 +((( 272 +DDS75-LB will uplink payload via LoRaWAN with below payload format: 273 +))) 239 239 240 -Users can use the downlink command(**0x26 01**) to ask S31x-LB to send device configure detail, include device configure status. S31x-LB will uplink a payload via FPort=5 to server. 275 +((( 276 +Uplink payload includes in total 4 bytes. 277 +Payload for firmware version v1.1.4. . Before v1.1.3, there is on two fields: BAT and Distance 278 +))) 279 +))) 241 241 242 -The Payload format is as below. 281 +((( 282 + 283 +))) 243 243 285 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:510px" %) 286 +|=(% style="width: 62.5px;background-color:#D9E2F3;color:#0070C0" %)((( 287 +**Size(bytes)** 288 +)))|=(% style="width: 62.5px;background-color:#D9E2F3;color:#0070C0" %)**2**|=(% style="background-color:#D9E2F3;color:#0070C0" %)**2**|=(% style="background-color:#D9E2F3;color:#0070C0" %)1|=(% style="background-color:#D9E2F3;color:#0070C0" %)2|=(% style="background-color:#D9E2F3;color:#0070C0" %)**1** 289 +|(% style="width:62.5px" %)**Value**|(% style="width:62.5px" %)[[BAT>>||anchor="H2.3.1A0BatteryInfo"]]|((( 290 +[[Distance>>||anchor="H2.3.2A0Distance"]] 291 +(unit: mm) 292 +)))|[[Digital Interrupt (Optional)>>||anchor="H2.3.3A0InterruptPin"]]|((( 293 +[[Temperature (Optional )>>||anchor="H2.3.4A0DS18B20Temperaturesensor"]] 294 +)))|[[Sensor Flag>>||anchor="H2.3.5A0SensorFlag"]] 244 244 245 -(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %) 246 -|(% colspan="6" style="background-color:#d9e2f3; color:#0070c0" %)**Device Status (FPORT=5)** 247 -|(% style="width:103px" %)**Size (bytes)**|(% style="width:72px" %)**1**|**2**|(% style="width:91px" %)**1**|(% style="width:86px" %)**1**|(% style="width:44px" %)**2** 248 -|(% style="width:103px" %)**Value**|(% style="width:72px" %)Sensor Model|Firmware Version|(% style="width:91px" %)Frequency Band|(% style="width:86px" %)Sub-band|(% style="width:44px" %)BAT 296 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDDS75%20-%20LoRaWAN%20Distance%20Detection%20Sensor%20User%20Manual/WebHome/1654850511545-399.png?rev=1.1||alt="1654850511545-399.png"]] 249 249 250 -Example parse in TTNv3 251 251 252 - [[image:image-20230421171614-1.png||alt="图片-20230421171614-1.png"]]299 +=== 2.3.1 Battery Info === 253 253 254 254 255 - (%style="color:#037691"%)**SensorModel**(%%):For S31x-LB, this value is 0x0A302 +Check the battery voltage for DDS75-LB. 256 256 257 - (% style="color:#037691" %)**Firmware Version**(%%): 0x0100,Means:v1.0.0 version304 +Ex1: 0x0B45 = 2885mV 258 258 259 - (% style="color:#037691"%)**FrequencyBand**:306 +Ex2: 0x0B49 = 2889mV 260 260 261 -*0x01: EU868 262 262 263 - *0x02:US915309 +=== 2.3.2 Distance === 264 264 265 -*0x03: IN865 266 266 267 -*0x04: AU915 312 +((( 313 +Get the distance. Flat object range 280mm - 7500mm. 314 +))) 268 268 269 -*0x05: KZ865 316 +((( 317 +For example, if the data you get from the register is 0x0B 0x05, the distance between the sensor and the measured object is(% style="color:#4472c4" %)** ** 270 270 271 -*0x06: RU864 319 +(% style="color:#4472c4" %)**0B05(H) = 2821 (D) = 2821 mm.** 320 +))) 272 272 273 -*0x07: AS923 274 274 275 -*0x08: AS923-1 323 +* If the sensor value is 0x0000, it means system doesn't detect ultrasonic sensor. 324 +* If the sensor value lower than 0x0118 (280mm), the sensor value will be invalid. Since v1.1.4, all value lower than 280mm will be set to 0x0014(20mm) which means the value is invalid. 276 276 277 - *0x09:AS923-2326 +=== 2.3.3 Interrupt Pin === 278 278 279 -*0x0a: AS923-3 280 280 281 - *0x0b:CN470329 +This data field shows if this packet is generated by interrupt or not. [[Click here>>||anchor="H3.3A0SetInterruptMode"]] for the hardware and software set up. 282 282 283 -* 0x0c:EU433331 +**Example:** 284 284 285 - *0x0d:KR920333 +0x00: Normal uplink packet. 286 286 287 - *0x0e:MA869335 +0x01: Interrupt Uplink Packet. 288 288 289 289 290 - (% style="color:#037691"%)**Sub-Band**:338 +=== 2.3.4 DS18B20 Temperature sensor === 291 291 292 -AU915 and US915:value 0x00 ~~ 0x08 293 293 294 - CN470:value0x0B~~0x0C341 +This is optional, user can connect external DS18B20 sensor to the +3.3v, 1-wire and GND pin . and this field will report temperature. 295 295 296 - Other Bands: Always 0x00343 +**Example**: 297 297 345 +If payload is: 0105H: (0105 & FC00 == 0), temp = 0105H /10 = 26.1 degree 298 298 299 - (%style="color:#037691"%)**Battery Info**:347 +If payload is: FF3FH : (FF3F & FC00 == 1) , temp = (FF3FH - 65536)/10 = -19.3 degrees. 300 300 301 - Checkthebatteryvoltage.349 +(% style="color:red" %)**Note: DS18B20 feature is supported in the hardware version > v1.3 which made since early of 2021.** 302 302 303 -Ex1: 0x0B45 = 2885mV 304 304 305 - Ex2:0x0B49=2889mV352 +=== 2.3.5 Sensor Flag === 306 306 307 307 308 -=== 2.3.2 Sensor Data. FPORT~=2 === 355 +((( 356 +0x01: Detect Ultrasonic Sensor 357 +))) 309 309 310 - 311 -Sensor Data is uplink via FPORT=2 312 - 313 -(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:700px" %) 314 -|=(% style="width: 90px;background-color:#D9E2F3" %)((( 315 -**Size(bytes)** 316 -)))|=(% style="width: 80px;background-color:#D9E2F3" %)2|=(% style="width: 90px;background-color:#D9E2F3" %)4|=(% style="width: 194px; background-color: rgb(217, 226, 243);" %)1|=(% style="width: 106px; background-color: rgb(217, 226, 243);" %)**2**|=(% style="width: 97px; background-color: rgb(217, 226, 243);" %)2 317 -|(% style="width:99px" %)**Value**|(% style="width:69px" %)((( 318 -Battery 319 -)))|(% style="width:130px" %)((( 320 -Unix TimeStamp 321 -)))|(% style="width:194px" %)((( 322 -Alarm Flag & 323 - 324 -MOD& 325 - 326 -Level of PA8 327 - 328 - 329 -)))|(% style="width:106px" %)((( 330 -Temperature 331 -)))|(% style="width:97px" %)((( 332 -Humidity 359 +((( 360 +0x00: No Ultrasonic Sensor 333 333 ))) 334 334 335 -==== (% style="color:#4472c4" %)**Battery**(%%) ==== 336 336 337 - SensorBatteryLevel.364 +=== 2.3.6 Decode payload in The Things Network === 338 338 339 -Ex1: 0x0B45 = 2885mV 340 340 341 - Ex2:0x0B49=2889mV367 +While using TTN network, you can add the payload format to decode the payload. 342 342 369 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDDS75%20-%20LoRaWAN%20Distance%20Detection%20Sensor%20User%20Manual/WebHome/1654850829385-439.png?rev=1.1||alt="1654850829385-439.png"]] 343 343 371 +The payload decoder function for TTN V3 is here: 344 344 345 -==== (% style="color:#4472c4" %)**Temperature**(%%) ==== 373 +((( 374 +DDS75-LB TTN V3 Payload Decoder: [[ttps:~~/~~/github.com/dragino/dragino-end-node-decoder>>https://github.com/dragino/dragino-end-node-decoder]] 375 +))) 346 346 347 -**Example**: 348 348 349 - Ifpayloadis:0105H: (0105 & 8000 == 0),temp=0105H /10=26.1 degree378 +== 2.4 Uplink Interval == 350 350 351 -If payload is: FF3FH : (FF3F & 8000 == 1) , temp = (FF3FH - 65536)/10 = -19.3 degrees. 352 352 353 - (FF3F&8000:Judgewhether the highestbitis1,whenthe highestbit is1,itisnegative)381 +The DDS75-LB by default uplink the sensor data every 20 minutes. User can change this interval by AT Command or LoRaWAN Downlink Command. See this link: [[Change Uplink Interval>>doc:Main.End Device AT Commands and Downlink Command.WebHome||anchor="H4.1ChangeUplinkInterval"]] 354 354 355 355 356 -== ==(%style="color:#4472c4"%)**Humidity**(%%)====384 +== 2.5 Show Data in DataCake IoT Server == 357 357 358 358 359 -Read:0x(0197)=412 Value: 412 / 10=41.2, So 41.2% 387 +((( 388 +[[DATACAKE>>url:https://datacake.co/]] provides a human friendly interface to show the sensor data, once we have data in TTN, we can use [[DATACAKE>>url:https://datacake.co/]] to connect to TTN and see the data in DATACAKE. Below are the steps: 389 +))) 360 360 391 +((( 392 + 393 +))) 361 361 362 -==== (% style="color:#4472c4" %)**Alarm Flag & MOD & Level of PA8**(%%) ==== 395 +((( 396 +(% style="color:blue" %)**Step 1**(%%)**: Be sure that your device is programmed and properly connected to the network at this time.** 397 +))) 363 363 399 +((( 400 +(% style="color:blue" %)**Step 2**(%%)**: To configure the Application to forward data to DATACAKE you will need to add integration. To add the DATACAKE integration, perform the following steps:** 401 +))) 364 364 365 -**Example:** 366 366 367 - Ifpayload & 0x01 = 0x01 **~-~->** Thisis anAlarmMessage.It meansthat thetemperatureandhumidity exceedthealarm valuetriggerinterrupt.404 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDDS75%20-%20LoRaWAN%20Distance%20Detection%20Sensor%20User%20Manual/WebHome/1654592790040-760.png?rev=1.1||alt="1654592790040-760.png"]] 368 368 369 -If payload & 0x01 = 0x00 **~-~->** This is a normal uplink message, no alarm. 370 370 371 - Ifpayload&0x80>>7 =0x01 **~-~->** ThePA8islowlevel.407 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDDS75%20-%20LoRaWAN%20Distance%20Detection%20Sensor%20User%20Manual/WebHome/1654592800389-571.png?rev=1.1||alt="1654592800389-571.png"]] 372 372 373 -If payload & 0x80>>7 =0x00 **~-~->** The PA8 is high level. 374 374 375 - Ifpayload>>2 = 0x00**~-~->**meansMOD=1, This isasamplinguplinkmessage.410 +(% style="color:blue" %)**Step 3**(%%)**: Create an account or log in Datacake.** 376 376 377 - Ifpayload>>2 = 0x31**~-~->**means MOD=31, this message is areply message for polling, thismessage contains thealarmsettings. see [[this link>>path:#HPolltheAlarmsettings:]]fordetail.412 +(% style="color:blue" %)**Step 4**(%%)**: Search the DDS75-LB and add DevEUI.** 378 378 414 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDDS75%20-%20LoRaWAN%20Distance%20Detection%20Sensor%20User%20Manual/WebHome/1654851029373-510.png?rev=1.1||alt="1654851029373-510.png"]] 379 379 380 -== 2.4 Payload Decoder file == 381 381 417 +After added, the sensor data arrive TTN V3, it will also arrive and show in Datacake. 382 382 383 - In TTN, usecandacustom payloadhowsfriendlyreading419 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDDS75%20-%20LoRaWAN%20Distance%20Detection%20Sensor%20User%20Manual/WebHome/image-20220610165129-11.png?width=1088&height=595&rev=1.1||alt="image-20220610165129-11.png"]] 384 384 385 -In the page (% style="color:#037691" %)**Applications ~-~-> Payload Formats ~-~-> Custom ~-~-> decoder**(%%) to add the decoder from: 386 386 387 -[[https:~~/~~/github.com/dragino/dragino-end-node-decoder/tree/main/S31-LB%26S31B-LB>>https://github.com/dragino/dragino-end-node-decoder/tree/main/S31-LB%26S31B-LB]] 388 388 423 +== 2.6 Datalog Feature == 389 389 390 -== 2.5 Datalog Feature == 391 391 426 +Datalog Feature is to ensure IoT Server can get all sampling data from Sensor even if the LoRaWAN network is down. For each sampling, SW3L-LB will store the reading for future retrieving purposes. 392 392 393 -Datalog Feature is to ensure IoT Server can get all sampling data from Sensor even if the LoRaWAN network is down. For each sampling, S31x-LB will store the reading for future retrieving purposes. 394 394 429 +=== 2.6.1 Ways to get datalog via LoRaWAN === 395 395 396 -=== 2.5.1 Ways to get datalog via LoRaWAN === 397 397 432 +Set PNACKMD=1, SW3L-LB will wait for ACK for every uplink, when there is no LoRaWAN network,SW3L-LB will mark these records with non-ack messages and store the sensor data, and it will send all messages (10s interval) after the network recovery. 398 398 399 -Set [[PNACKMD=1>>||anchor="H2.5.4DatalogUplinkpayload28FPORT3D329"]], S31x-LB will wait for ACK for every uplink, when there is no LoRaWAN network,S31x-LB will mark these records with non-ack messages and store the sensor data, and it will send all messages (10s interval) after the network recovery. 400 - 401 401 * ((( 402 -a) S3 1x-LB will do an ACK check for data records sending to make sure every data arrive server.435 +a) SW3L-LB will do an ACK check for data records sending to make sure every data arrive server. 403 403 ))) 404 404 * ((( 405 -b) S3 1x-LB will send data in **CONFIRMED Mode** when PNACKMD=1, but S31x-LB won't re-transmit the packet if it doesn't get ACK, it will just mark it as a NONE-ACK message. In a future uplink if S31x-LB gets a ACK, S31x-LB will consider there is a network connection and resend all NONE-ACK messages.438 +b) SW3L-LB will send data in **CONFIRMED Mode** when PNACKMD=1, but SW3L-LB won't re-transmit the packet if it doesn't get ACK, it will just mark it as a NONE-ACK message. In a future uplink if SW3L-LB gets a ACK, SW3L-LB will consider there is a network connection and resend all NONE-ACK messages. 406 406 ))) 407 407 408 408 Below is the typical case for the auto-update datalog feature (Set PNACKMD=1) ... ... @@ -410,10 +410,10 @@ 410 410 [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/WebHome/image-20220703111700-2.png?width=1119&height=381&rev=1.1||alt="图片-20220703111700-2.png" height="381" width="1119"]] 411 411 412 412 413 -=== 2. 5.2 Unix TimeStamp ===446 +=== 2.6.2 Unix TimeStamp === 414 414 415 415 416 -S3 1x-LB uses Unix TimeStamp format based on449 +SW3L-LB uses Unix TimeStamp format based on 417 417 418 418 [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/WebHome/image-20220523001219-11.png?width=627&height=97&rev=1.1||alt="图片-20220523001219-11.png" height="97" width="627"]] 419 419 ... ... @@ -427,148 +427,62 @@ 427 427 So, we can use AT+TIMESTAMP=1611889405 or downlink 3060137afd00 to set the current time 2021 – Jan ~-~- 29 Friday 03:03:25 428 428 429 429 430 -=== 2. 5.3 Set Device Time ===463 +=== 2.6.3 Set Device Time === 431 431 432 432 433 433 User need to set (% style="color:blue" %)**SYNCMOD=1**(%%) to enable sync time via MAC command. 434 434 435 -Once S3 1x-LB Joined LoRaWAN network, it will send the MAC command (DeviceTimeReq) and the server will reply with (DeviceTimeAns) to send the current time to S31x-LB. If S31x-LB fails to get the time from the server, S31x-LB will use the internal time and wait for next time request (AT+SYNCTDC to set the time request period, default is 10 days).468 +Once SW3L-LB Joined LoRaWAN network, it will send the MAC command (DeviceTimeReq) and the server will reply with (DeviceTimeAns) to send the current time to SW3L-LB. If SW3L-LB fails to get the time from the server, SW3L-LB will use the internal time and wait for next time request (AT+SYNCTDC to set the time request period, default is 10 days). 436 436 437 437 (% style="color:red" %)**Note: LoRaWAN Server need to support LoRaWAN v1.0.3(MAC v1.0.3) or higher to support this MAC command feature, Chirpstack,TTN V3 v3 and loriot support but TTN V3 v2 doesn't support. If server doesn't support this command, it will through away uplink packet with this command, so user will lose the packet with time request for TTN V3 v2 if SYNCMOD=1.** 438 438 439 439 440 -=== 2. 5.4Datalog Uplinkpayload(FPORT~=3)===473 +=== 2.6.4 Poll sensor value === 441 441 442 442 443 - TheDataloguplinkswilluse belowpayloadformat.476 +Users can poll sensor values based on timestamps. Below is the downlink command. 444 444 445 -**Retrieval data payload:** 478 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:425.818px" %) 479 +|(% colspan="4" style="background-color:#d9e2f3; color:#0070c0; width:423px" %)**Downlink Command to poll Open/Close status (0x31)** 480 +|(% style="width:58px" %)**1byte**|(% style="width:127px" %)**4bytes**|(% style="width:124px" %)**4bytes**|(% style="width:114px" %)**1byte** 481 +|(% style="width:58px" %)31|(% style="width:127px" %)Timestamp start|(% style="width:124px" %)Timestamp end|(% style="width:114px" %)Uplink Interval 446 446 447 -(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:680px" %) 448 -|=(% style="width: 80px;background-color:#D9E2F3" %)((( 449 -**Size(bytes)** 450 -)))|=(% style="width: 68px; background-color: rgb(217, 226, 243);" %)**2**|=(% style="width: 104px; background-color: rgb(217, 226, 243);" %)**2**|=(% style="width: 87px; background-color: rgb(217, 226, 243);" %)**2**|=(% style="width: 178px; background-color: rgb(217, 226, 243);" %)**1**|=(% style="width: 137px; background-color: rgb(217, 226, 243);" %)**4** 451 -|(% style="width:103px" %)**Value**|(% style="width:68px" %)((( 452 -ignore 453 -)))|(% style="width:104px" %)((( 454 454 ((( 455 - Humidity484 +Timestamp start and Timestamp end-use Unix TimeStamp format as mentioned above. Devices will reply with all data logs during this period, using the uplink interval. 456 456 ))) 457 457 458 458 ((( 459 - 488 +For example, downlink command [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/CPL01%20LoRaWAN%20Outdoor%20PulseContact%20%20Sensor%20Manual/WebHome/image-20220518162852-1.png?rev=1.1||alt="image-20220518162852-1.png"]] 460 460 ))) 461 -)))|(% style="width:87px" %)((( 462 -Temperature 463 -)))|(% style="width:178px" %)((( 464 -Poll message flag & 465 465 466 -Alarm Flag& 467 - 468 -Level of PA8 469 -)))|(% style="width:137px" %)Unix Time Stamp 470 - 471 -**Poll message flag & Alarm Flag & Level of PA8:** 472 - 473 -[[image:image-20230524114302-1.png||height="115" width="736"]] 474 - 475 - 476 -**No ACK Message**: 1: This message means this payload is fromn Uplink Message which doesn't get ACK from the server before ( for **PNACKMD=1** feature) 477 - 478 -**Poll Message Flag**: 1: This message is a poll message reply. 479 - 480 -* Poll Message Flag is set to 1. 481 - 482 -* Each data entry is 11 bytes, to save airtime and battery, devices will send max bytes according to the current DR and Frequency bands. 483 - 484 -For example, in US915 band, the max payload for different DR is: 485 - 486 -**a) DR0:** max is 11 bytes so one entry of data 487 - 488 -**b) DR1:** max is 53 bytes so devices will upload 4 entries of data (total 44 bytes) 489 - 490 -**c) DR2:** total payload includes 11 entries of data 491 - 492 -**d) DR3: **total payload includes 22 entries of data. 493 - 494 -If devise doesn't have any data in the polling time. Device will uplink 11 bytes of 0 495 - 496 -**Example:** 497 - 498 -If S31x-LB has below data inside Flash: 499 - 500 -[[image:image-20230524114654-2.png]] 501 - 502 - 503 -If user sends below downlink command: 31646D84E1646D856C05 504 - 505 -Where : Start time: 646D84E1 = time 23/5/24 03:30:41 506 - 507 - Stop time: 646D856C= time 23/5/24 03:33:00 508 - 509 - 510 -**S31x-LB will uplink this payload.** 511 - 512 -[[image:image-20230524114826-3.png]] 513 - 514 514 ((( 515 - 00000236010 40 64 6D 84 E100 00 0237 0110 40 64 6D 84 F8 00 00 0237010F 4064 6D 85040000 023A010F 40 64 6D 8518 00 00 02 3C 010F 40 64 6D 85 36 00 00 02 3D 010E 40 64 6D 85 3F 00 00 023F 010E 40 64 6D 8560002 40 01 0E 40 64 6D 85 6A492 +Is to check 2021/11/12 12:00:00 to 2021/11/12 15:00:00's data 516 516 ))) 517 517 518 518 ((( 519 - Wherethefirst11 bytes isfor thefirst entry:496 +Uplink Internal =5s,means SW3L-LB will send one packet every 5s. range 5~~255s. 520 520 ))) 521 521 522 -((( 523 -00 00 02 36 01 10 40 64 6D 84 E1 524 -))) 525 525 526 -((( 527 -**Hum**=0x0236/10=56.6 528 -))) 529 - 530 -((( 531 -**Temp**=0x0110/10=27.2 532 -))) 533 - 534 -((( 535 -**poll message flag & Alarm Flag & Level of PA8**=0x40,means reply data,sampling uplink message,the PA8 is low level. 536 -))) 537 - 538 -((( 539 -**Unix time** is 0x646D84E1=1684899041s=23/5/24 03:30:41 540 -))) 541 - 542 - 543 -(% aria-label="数据 URI 图像图像小部件" contenteditable="false" role="region" style="background-image:url(http://wiki1.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" tabindex="-1" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||alt="数据 URI 图片" data-widget="image" draggable="true" height="15" role="presentation" title="单击并拖动以移动" width="15"]](% aria-label="数据 URI 图像图像小部件" contenteditable="false" role="region" style="background-image:url(http://wiki1.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220, 220, 220, 0.5); display:none" tabindex="-1" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||alt="数据 URI 图片" draggable="true" height="15" role="presentation" title="单击并拖动以移动" width="15"]](% aria-label="数据 URI 图像图像小部件" contenteditable="false" role="region" style="background-image:url(http://wiki1.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" tabindex="-1" title="单击并拖动以调整大小" %)的(% aria-label="数据 URI 图像图像小部件" contenteditable="false" role="region" style="background-image:url(http://wiki1.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" tabindex="-1" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||alt="数据 URI 图片" data-widget="image" draggable="true" height="15" role="presentation" title="单击并拖动以移动" width="15"]](% aria-label="数据 URI 图像图像小部件" contenteditable="false" role="region" style="background-image:url(http://wiki1.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220, 220, 220, 0.5); display:none" tabindex="-1" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||alt="数据 URI 图片" draggable="true" height="15" role="presentation" title="单击并拖动以移动" width="15"]](% aria-label="数据 URI 图像图像小部件" contenteditable="false" role="region" style="background-image:url(http://wiki1.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" tabindex="-1" title="单击并拖动以调整大小" %)的 544 - 545 -== 2.6 Temperature Alarm Feature == 546 - 547 - 548 -S31x-LB work flow with Alarm feature. 549 - 550 - 551 -[[image:image-20230524110125-3.png||height="768" width="1115"]] 552 - 553 - 554 - 555 555 == 2.7 Frequency Plans == 556 556 557 557 558 -The S3 1x-LB uses OTAA mode and below frequency plans by default. If user want to use it with different frequency plan, please refer the AT command sets.503 +The SW3L-LB uses OTAA mode and below frequency plans by default. If user want to use it with different frequency plan, please refer the AT command sets. 559 559 560 560 [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20Frequency%20Band/>>http://wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20Frequency%20Band/]] 561 561 562 562 563 -= 3. Configure S3 1x-LB =508 += 3. Configure SW3L-LB = 564 564 565 565 == 3.1 Configure Methods == 566 566 567 567 568 -S3 1x-LB supports below configure method:513 +SW3L-LB supports below configure method: 569 569 570 570 * AT Command via Bluetooth Connection (**Recommended**): [[BLE Configure Instruction>>http://wiki.dragino.com/xwiki/bin/view/Main/BLE%20Bluetooth%20Remote%20Configure/]]. 516 + 571 571 * AT Command via UART Connection : See [[UART Connection>>http://wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H2.3UARTConnectionforSN50v3basemotherboard]]. 518 + 572 572 * LoRaWAN Downlink. Instruction for different platforms: See [[IoT LoRaWAN Server>>http://wiki.dragino.com/xwiki/bin/view/Main/]] section. 573 573 574 574 == 3.2 General Commands == ... ... @@ -577,6 +577,7 @@ 577 577 These commands are to configure: 578 578 579 579 * General system settings like: uplink interval. 527 + 580 580 * LoRaWAN protocol & radio related command. 581 581 582 582 They are same for all Dragino Devices which support DLWS-005 LoRaWAN Stack. These commands can be found on the wiki: ... ... @@ -584,21 +584,25 @@ 584 584 [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/>>http://wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/]] 585 585 586 586 587 -== 3.3 Commands special design for S3 1x-LB ==535 +== 3.3 Commands special design for SW3L-LB == 588 588 589 589 590 -These commands only valid for S3 1x-LB, as below:538 +These commands only valid for SW3L-LB, as below: 591 591 592 592 593 593 === 3.3.1 Set Transmit Interval Time === 594 594 595 595 544 +((( 596 596 Feature: Change LoRaWAN End Node Transmit Interval. 546 +))) 597 597 548 +((( 598 598 (% style="color:blue" %)**AT Command: AT+TDC** 550 +))) 599 599 600 600 (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %) 601 -|=(% style="width: 156px;background-color:#D9E2F3" %)**Command Example**|=(% style="width: 137px;background-color:#D9E2F3" %)**Function**|=(% style="background-color:#D9E2F3" %)**Response** 553 +|=(% style="width: 156px;background-color:#D9E2F3; color:#0070c0" %)**Command Example**|=(% style="width: 137px;background-color:#D9E2F3; color:#0070c0" %)**Function**|=(% style="background-color:#D9E2F3; color:#0070c0" %)**Response** 602 602 |(% style="width:156px" %)AT+TDC=?|(% style="width:137px" %)Show current transmit Interval|((( 603 603 30000 604 604 OK ... ... @@ -609,18 +609,44 @@ 609 609 Set transmit interval to 60000ms = 60 seconds 610 610 ))) 611 611 564 +((( 612 612 (% style="color:blue" %)**Downlink Command: 0x01** 566 +))) 613 613 568 +((( 614 614 Format: Command Code (0x01) followed by 3 bytes time value. 570 +))) 615 615 572 +((( 616 616 If the downlink payload=0100003C, it means set the END Node's Transmit Interval to 0x00003C=60(S), while type code is 01. 574 +))) 617 617 618 -* Example 1: Downlink Payload: 0100001E ~/~/ Set Transmit Interval (TDC) = 30 seconds 619 -* Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds 576 +* ((( 577 +Example 1: Downlink Payload: 0100001E ~/~/ Set Transmit Interval (TDC) = 30 seconds 578 +))) 579 +* ((( 580 +Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds 581 +))) 620 620 621 -=== 3.3.2 GetDeviceStatus===583 +=== 3.3.2 Quit AT Command === 622 622 623 623 586 +Feature: Quit AT Command mode, so user needs to input the password again before using AT Commands. 587 + 588 +(% style="color:blue" %)**AT Command: AT+DISAT** 589 + 590 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:452px" %) 591 +|=(% style="width: 155px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 198px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 99px;background-color:#D9E2F3;color:#0070C0" %)**Response** 592 +|(% style="width:155px" %)AT+DISAT|(% style="width:198px" %)Quit AT Commands mode|(% style="width:96px" %)OK 593 + 594 +(% style="color:blue" %)**Downlink Command:** 595 + 596 +No downlink command for this feature. 597 + 598 + 599 +=== 3.3.3 Get Device Status === 600 + 601 + 624 624 Send a LoRaWAN downlink to ask device send Alarm settings. 625 625 626 626 (% style="color:blue" %)**Downlink Payload: **(%%)0x26 01 ... ... @@ -628,82 +628,140 @@ 628 628 Sensor will upload Device Status via FPORT=5. See payload section for detail. 629 629 630 630 631 -=== 3.3. 3Set TemperatureAlarmThreshold===609 +=== 3.3.4 Alarm for continuously water flow === 632 632 633 633 634 -* (% style="color:blue" %)**AT Command:** 612 +((( 613 +This feature is to monitor and send Alarm for continuously water flow. 614 +))) 635 635 636 -(% style="color:#037691" %)**AT+SHTEMP=min,max** 616 +((( 617 +Example case is for Toilet water monitoring, if some one push toilet button, the toilet will have water flow. If the toilet button has broken and can't returned to original state, the water flow will keep for hours or days which cause huge waste for water. 618 +))) 637 637 638 - * When min=0, and max≠0, Alarm higher than max639 - *Whenmin≠0,andmax=0,Alarmlowerthanmin640 - * When min≠0 and max≠0, Alarm higher than max or lower than min620 +((( 621 +To monitor this faulty and send alarm, there are two settings: 622 +))) 641 641 642 -Example: 624 +* ((( 625 +(% style="color:#4f81bd" %)**Stop Duration: Unit: Second** 626 +))) 643 643 644 - AT+SHTEMP=0,30 ~/~/ Alarm when temperature higher than 30. 628 +((( 629 +Default: 15s, If SW3L-LB didn't see any water flow in 15s, SW3L-LB will consider stop of water flow event. 630 +))) 645 645 646 -* (% style="color:blue" %)**Downlink Payload:** 632 +* ((( 633 +(% style="color:#4f81bd" %)**Alarm Timer: Units: Minute; Default 0 minutes (means Alarm disable)** 634 +))) 647 647 648 -(% style="color:#037691" %)**0x(0C 01 00 1E)** (%%) ~/~/ Set AT+SHTEMP=0,30 636 +((( 637 +**Example:** 3 minutes, if SW3L-LB detect a start of water flow event and didn't detect a stop event within Alarm timer, SW3L-LB will send an Alarm to indicate a water flow abnormal alarm. 638 +))) 649 649 650 -(% style="color:red" %)**(note: 3^^rd^^ byte= 0x00 for low limit(not set), 4^^th^^ byte = 0x1E for high limit: 30)** 640 +((( 641 +So for example, If we set stop duration=15s and Alarm Timer=3minutes. If the toilet water flow continuously for more than 3 minutes, Sensor will send an alarm (in Confirmed MODE) to platform. 642 +))) 651 651 644 +((( 645 +(% style="color:red" %)**Note:** **After this alarm is send, sensor will consider a stop of water flow and count for another new event. So if water flow waste last for 1 hour, Sensor will keep sending alarm every 3 minutes.** 646 +))) 652 652 653 -=== 3.3.4 Set Humidity Alarm Threshold === 648 +((( 649 +(% style="color:#4f81bd" %)**AT Command**(%%) to configure: 650 +))) 654 654 652 +* ((( 653 +AT+PTRIG=15,3 ~-~-> Set Stop duration: 15s, Alarm Timer: 3 minutes. 654 +))) 655 655 656 -* (% style="color:blue" %)**AT Command:** 656 +* ((( 657 +AT+ PTRIG=15,0 ~-~-> Default Value, disable water waste Alarm. 658 +))) 657 657 658 -(% style="color:#037691" %)**AT+SHHUM=min,max** 660 +((( 661 +(% style="color:#4f81bd" %)**Downlink Command**(%%) to configure: 662 +))) 659 659 660 - * When min=0, and max≠0, Alarm higher than max661 - * Whenmin≠0,andmax=0,Alarmlower thanmin662 - * When min≠0 and max≠0, Alarm higher than max or lower than min664 +((( 665 +Command: **0xAA aa bb cc** 666 +))) 663 663 664 -Example: 668 +((( 669 +AA: Command Type Code 670 +))) 665 665 666 - AT+SHHUM=70,0 ~/~/ Alarm when humidity lower than 70%. 672 +((( 673 +aa: Stop duration 674 +))) 667 667 668 -* (% style="color:blue" %)**Downlink Payload:** 676 +((( 677 +bb cc: Alarm Timer 678 +))) 669 669 670 -(% style="color:#037691" %)**0x(0C 02 46 00)**(%%) ~/~/ Set AT+SHTHUM=70,0 680 +((( 681 +If user send 0xAA 0F 00 03: equal to AT+PTRIG=15,3 682 +))) 671 671 672 -(% style="color:red" %)**(note: 3^^rd^^ byte= 0x46 for low limit (70%), 4^^th^^ byte = 0x00 for high limit (not set))** 673 673 685 +=== 3.3.5 Clear Flash Record === 674 674 675 -=== 3.3.5 Set Alarm Interval === 676 676 688 +Feature: Clear flash storage for data log feature. 677 677 678 - Theshortest timeof two Alarmpacket. (unit:min)690 +(% style="color:blue" %)**AT Command: AT+CLRDTA** 679 679 680 -* (% style="color:blue" %)**AT Command:** 692 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:500px" %) 693 +|=(% style="width: 157px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 169px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 174px;background-color:#D9E2F3;color:#0070C0" %)**Response** 694 +|(% style="width:157px" %)AT+CLRDTA|(% style="width:169px" %)Clear flash storage for data log feature.|Clear all stored sensor data… OK 681 681 682 -(% style="color:#037691" %)**AT+ATDC=30** (%%) ~/~/ The shortest interval of two Alarm packets is 30 minutes, Means is there is an alarm packet uplink, there won't be another one in the next 30 minutes. 696 +((( 697 +(% style="color:blue" %)**Downlink Command:** 698 +))) 683 683 684 -* (% style="color:blue" %)**Downlink Payload:** 700 +((( 701 +* **Example**: 0xA301 ~/~/ Same as AT+CLRDTA 702 +))) 685 685 686 -(% style="color:#037691" %)**0x(0D 00 1E)**(%%) **~-~--> ** Set AT+ATDC=0x 00 1E = 30 minutes 687 687 688 688 689 -=== 3.3.6 GetAlarm settings===706 +=== 3.3.6 Set the calculate flag === 690 690 691 691 692 - SendaLoRaWANdownlinktoask devicesend Alarm settings.709 +Feature: Set the calculate flag 693 693 694 - *(% style="color:#037691" %)**DownlinkPayload:(%%)0x0E 01711 +(% style="color:blue" %)**AT Command: AT+CALCFLAG** 695 695 696 -**Example:** 713 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:461px" %) 714 +|=(% style="width: 158px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 193px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 110px;background-color:#D9E2F3;color:#0070C0" %)**Response** 715 +|(% style="width:158px" %)AT+CALCFLAG =1|(% style="width:192px" %)Set the calculate flag to 1.|(% style="width:109px" %)OK 716 +|(% style="width:158px" %)AT+CALCFLAG =2|(% style="width:192px" %)Set the calculate flag to 2.|(% style="width:109px" %)OK 697 697 698 - [[image:image-20230524110211-4.png]]718 +(% style="color:blue" %)**Downlink Command:** 699 699 700 -**Expl ain:**720 +* **Example**: 0XA501 ~/~/ Same as AT+CALCFLAG =1 701 701 702 - * Alarm & MOD bit is 0x7C, 0x7C >> 2=0x31:Meansthismessage istheAlarm settingsmessage.722 +=== 3.3.7 Set count number === 703 703 704 -=== 3.3.7 Set Interrupt Mode === 705 705 725 +Feature: Manually set the count number 706 706 727 +(% style="color:blue" %)**AT Command: AT+SETCNT** 728 + 729 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:479px" %) 730 +|=(% style="width: 160px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 223px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 96px;background-color:#D9E2F3;color:#0070C0" %)**Response** 731 +|(% style="width:160px" %)AT+ SETCNT =0|(% style="width:221px" %)Set the count number to 0.|(% style="width:95px" %)OK 732 +|(% style="width:160px" %)AT+ SETCNT =100|(% style="width:221px" %)Set the count number to 100.|(% style="width:95px" %)OK 733 + 734 +(% style="color:blue" %)**Downlink Command:** 735 + 736 +* **Example**: 0xA6000001 ~/~/ Same as AT+ SETCNT =1 737 + 738 +* **Example**: 0xA6000064 ~/~/ Same as AT+ SETCNT =100 739 + 740 +=== 3.3.8 Set Interrupt Mode === 741 + 742 + 707 707 Feature, Set Interrupt mode for PA8 of pin. 708 708 709 709 When AT+INTMOD=0 is set, PA8 is used as a digital input port. ... ... @@ -711,7 +711,7 @@ 711 711 (% style="color:blue" %)**AT Command: AT+INTMOD** 712 712 713 713 (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %) 714 -|=(% style="width: 15 4px;background-color:#D9E2F3" %)**Command Example**|=(% style="width: 196px;background-color:#D9E2F3" %)**Function**|=(% style="width: 157px;background-color:#D9E2F3" %)**Response**750 +|=(% style="width: 155px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 197px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 158px;background-color:#D9E2F3;color:#0070C0" %)**Response** 715 715 |(% style="width:154px" %)AT+INTMOD=?|(% style="width:196px" %)Show current interrupt mode|(% style="width:157px" %)((( 716 716 0 717 717 OK ... ... @@ -732,40 +732,32 @@ 732 732 This means that the interrupt mode of the end node is set to 0x000003=3 (rising edge trigger), and the type code is 06. 733 733 734 734 * Example 1: Downlink Payload: 06000000 ~/~/ Turn off interrupt mode 771 + 735 735 * Example 2: Downlink Payload: 06000003 ~/~/ Set the interrupt mode to rising edge trigger 736 736 737 -=== 3.3. 8SetPowerOutput Duration===774 +=== 3.3.9 Set work mode === 738 738 739 739 740 - Control theoutput duration5V . Beforeeach sampling,device will777 +Feature: Manually set the work mode 741 741 742 -~1. first enable the power output to external sensor, 743 743 744 - 2.keep it on asper duration, read sensorvalueandconstruct uplink payload780 +(% style="color:blue" %)**AT Command: AT+MOD** 745 745 746 -3. final, close the power output. 782 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:463px" %) 783 +|=(% style="width: 162px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 193px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 108px;background-color:#D9E2F3;color:#0070C0" %)**Response** 784 +|(% style="width:162px" %)AT+MOD=0|(% style="width:191px" %)Set the work mode to 0.|(% style="width:106px" %)OK 785 +|(% style="width:162px" %)AT+MOD=1|(% style="width:191px" %)Set the work mode to 1|(% style="width:106px" %)OK 747 747 748 -(% style="color:blue" %)** ATCommand:AT+5VT**787 +(% style="color:blue" %)**Downlink Command:** 749 749 750 -(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %) 751 -|=(% style="width: 154px;background-color:#D9E2F3" %)**Command Example**|=(% style="width: 196px;background-color:#D9E2F3" %)**Function**|=(% style="width: 157px;background-color:#D9E2F3" %)**Response** 752 -|(% style="width:154px" %)AT+5VT=?|(% style="width:196px" %)Show 5V open time.|(% style="width:157px" %)0 (default) 753 -OK 754 -|(% style="width:154px" %)AT+5VT=500|(% style="width:196px" %)Close after a delay of 1000 milliseconds.|(% style="width:157px" %)OK 789 +* **Example: **0x0A00 ~/~/ Same as AT+MOD=0 755 755 756 - (%style="color:blue" %)**DownlinkCommand:0x07**791 +* **Example:** 0x0A01 ~/~/ Same as AT+MOD=1 757 757 758 -Format: Command Code (0x07) followed by 2 bytes. 759 - 760 -The first and second bytes are the time to turn on. 761 - 762 -* Example 1: Downlink Payload: 070000 **~-~-->** AT+5VT=0 763 -* Example 2: Downlink Payload: 0701F4 **~-~-->** AT+5VT=500 764 - 765 765 = 4. Battery & Power Consumption = 766 766 767 767 768 -S3 1x-LB use ER26500 + SPC1520 battery pack. See below link for detail information about the battery info and how to replace.796 +SW3L-LB use ER26500 + SPC1520 battery pack. See below link for detail information about the battery info and how to replace. 769 769 770 770 [[**Battery Info & Power Consumption Analyze**>>http://wiki.dragino.com/xwiki/bin/view/Main/How%20to%20calculate%20the%20battery%20life%20of%20Dragino%20sensors%3F/]] . 771 771 ... ... @@ -774,30 +774,36 @@ 774 774 775 775 776 776 (% class="wikigeneratedid" %) 777 -User can change firmware S3 1x-LB to:805 +User can change firmware SW3L-LB to: 778 778 779 779 * Change Frequency band/ region. 808 + 780 780 * Update with new features. 810 + 781 781 * Fix bugs. 782 782 783 783 Firmware and changelog can be downloaded from : **[[Firmware download link>>url:https://www.dropbox.com/sh/kwqv57tp6pejias/AAAopYMATh1GM6fZ-VRCLrpDa?dl=0]]** 784 784 785 - 786 786 Methods to Update Firmware: 787 787 788 788 * (Recommanded way) OTA firmware update via wireless: [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/Firmware%20OTA%20Update%20for%20Sensors/>>url:http://wiki.dragino.com/xwiki/bin/view/Main/Firmware%20OTA%20Update%20for%20Sensors/]] 818 + 789 789 * Update through UART TTL interface. **[[Instruction>>url:http://wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H1.LoRaSTv4baseHardware]]**. 790 790 791 791 = 6. FAQ = 792 792 823 +== 6.1 AT Commands input doesn't work == 793 793 794 794 826 +In the case if user can see the console output but can't type input to the device. Please check if you already include the (% style="color:green" %)**ENTER**(%%) while sending out the command. Some serial tool doesn't send (% style="color:green" %)**ENTER**(%%) while press the send key, user need to add ENTER in their string. 827 + 828 + 795 795 = 7. Order Info = 796 796 797 797 798 -Part Number: (% style="color:blue" %)**S3 1-LB-XX / S31B-LB-XX**832 +Part Number: (% style="color:blue" %)**SW3L-LB-XXX-YYY** 799 799 800 -(% style="color:red" %)**XX**(%%): The default frequency band 834 +(% style="color:red" %)**XXX**(%%): The default frequency band 801 801 802 802 * (% style="color:red" %)**AS923**(%%): LoRaWAN AS923 band 803 803 ... ... @@ -815,12 +815,43 @@ 815 815 816 816 * (% style="color:red" %)**CN470**(%%): LoRaWAN CN470 band 817 817 852 +((( 853 +(% style="color:blue" %)**YYY**(%%): Flow Sensor Model: 854 +))) 855 + 856 +((( 857 + **004:** DW-004 Flow Sensor: diameter: G1/2” / DN15. 450 pulse = 1 L 858 +))) 859 + 860 +((( 861 + **006:** DW-006 Flow Sensor: diameter: G3/4” / DN20. 390 pulse = 1 L 862 +))) 863 + 864 +((( 865 + **010:** DW-010 Flow Sensor: diameter: G 1” / DN25. 64 pulse = 1 L 866 +))) 867 + 868 +* ((( 869 +calculate flag=0: for SW3L-004 Flow Sensor: 450 pulse = 1 L 870 +))) 871 + 872 +* ((( 873 +calculate flag=1: for SW3L-006 Flow Sensor: 390 pulse = 1 L 874 +))) 875 + 876 +* ((( 877 +calculate flag=2: for SW3L-010 Flow Sensor: 64 pulse = 1 L 878 + 879 + 880 + 881 +))) 882 + 818 818 = 8. Packing Info = 819 819 820 820 821 821 (% style="color:#037691" %)**Package Includes**: 822 822 823 -* S3 1x-LB LoRaWANTemperature& HumiditySensor888 +* SW3L-LB LoRaWAN Flow Sensor 824 824 825 825 (% style="color:#037691" %)**Dimension and weight**: 826 826
- image-20230524144456-2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +33.9 KB - Content
- image-20230527093155-1.jpeg
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +9.3 KB - Content
- image-20230527093214-2.jpeg
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +14.7 KB - Content
- image-20230530084138-1.jpeg
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +1.1 MB - Content
- image-20230530084608-2.jpeg
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +1.1 MB - Content
- image-20230530111051-3.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +85.1 KB - Content
- image-20230530111412-4.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +85.0 KB - Content
- image-20230530135919-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +87.6 KB - Content
- image-20230530135929-2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +87.6 KB - Content
- image-20230530140053-1.jpeg
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +1.3 MB - Content
- image-20230612170349-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +164.2 KB - Content
- image-20230612170943-2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +86.4 KB - Content
- image-20230612171032-3.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +86.4 KB - Content