Changes for page DS20L -- LoRaWAN Smart Distance Detector User Manual 01
Last modified by Mengting Qiu on 2023/12/14 11:15
Summary
-
Page properties (3 modified, 0 added, 0 removed)
-
Attachments (0 modified, 13 added, 0 removed)
- image-20230524105433-1.png
- image-20230524105747-2.png
- image-20230524110125-3.png
- image-20230524110211-4.png
- image-20230524114302-1.png
- image-20230524114654-2.png
- image-20230524114826-3.png
- image-20230524144422-1.png
- image-20230524144456-2.png
- image-20230527093155-1.jpeg
- image-20230527093214-2.jpeg
- image-20230530084138-1.jpeg
- image-20230530084608-2.jpeg
Details
- Page properties
-
- Title
-
... ... @@ -1,1 +1,1 @@ 1 - S31-LB/ S31B-LBLoRaWANOutdoor Temperature& HumiditySensor User Manual1 +CPL03-LB -- LoRaWAN Pulse/Contact Sensor User Manual - Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Saxer1 +XWiki.Xiaoling - Content
-
... ... @@ -1,9 +1,7 @@ 1 1 (% style="text-align:center" %) 2 -[[image: S31-B.jpg]]2 +[[image:image-20230530084608-2.jpeg||height="707" width="707"]] 3 3 4 4 5 - 6 - 7 7 **Table of Contents:** 8 8 9 9 {{toc/}} ... ... @@ -15,36 +15,40 @@ 15 15 16 16 = 1. Introduction = 17 17 18 -== 1.1 What is S31x-LB LoRaWANTemperature& HumiditySensor ==16 +== 1.1 What is CPL03-LB LoRaWAN Pulse/Contact Sensor == 19 19 20 20 21 -The Dragino S31x-LB is a (% style="color:blue" %)**LoRaWANTemperatureand HumiditySensor**(%%) for Internet of Things solution. Itis usedto measurethe(% style="color:blue" %)**surroundingenvironment temperatureandrelativeair humidityprecisely**(%%), and then upload to IoT server via LoRaWAN wireless protocol.19 +The Dragino CPL03-LB is a (% style="color:blue" %)**LoRaWAN Contact Sensor**(%%) for Internet of Things solution. It detects dry contact status, open time, open counts, and then upload to IoT server via LoRaWAN wireless protocol. 22 22 23 -The temperature & humiditysensorusedinS31x-LBisSHT31,whichis fully calibrated,linearized,andtemperaturecompensateddigitaloutputfrom Sensirion,it provides a strongreliabilityandlong-termstability.TheSHT31isfixed ina(%style="color:blue" %)**waterproofanti-condensationcasing**(%%) forlongterm use.21 +The CPL03-LB will send periodically data every day as well as for each dry contact action. It also counts the contact open times and calculate last open duration. User can also disable the uplink for each open/close event, instead, device can count each open event and uplink periodically. 24 24 25 -The LoRa wireless technology used in S31x-LB allows device to send data and reach extremely long ranges at low data-rates. It provides ultra-long range spread spectrum communication and high interference immunity whilst minimizing current consumption.23 +The LoRa wireless technology used in CPL03-LB allows device to send data and reach extremely long ranges at low data-rates. It provides ultra-long range spread spectrum communication and high interference immunity whilst minimizing current consumption. 26 26 27 - S31x-LBsupports(% style="color:blue" %)**Temperature& Humdityalarm feature**(%%), user can settemperaturealarm for instant notice.S31x-LB supports Datalog feature, it can save the data when there is no LoRaWAN network and uplink when network recover.25 +CPL03-LB (% style="color:blue" %)**supports open alarm feature**(%%), user can set open alarm for instant notice. CPL03-LB (% style="color:blue" %)**supports Datalog feature**(%%), it can save the data when there is no LoRaWAN network and uplink when network recover. 28 28 29 - S31x-LB(%style="color:blue"%)**supportsBLEconfigure**(%%)and(%style="color:blue"%)**wirelessOTAupdate**(%%)which makeusereasytouse.27 +CPL03-LB is designed for outdoor use. It has a weatherproof enclosure and industrial level battery to work in low to high temperatures. 30 30 31 - S31x-LBis poweredby(% style="color:blue" %)**8500mAh Li-SOCI2battery**(%%),itis designed forlong term useupto5 years.29 +CPL03-LB (% style="color:blue" %)**supports BLE configure**(%%) and (% style="color:blue" %)**wireless OTA update**(%%) which make user easy to use. 32 32 33 - Each S31x-LB is pre-loadwithasetfuniquekeys for LoRaWANregistrations, register thesekeysto localLoRaWANserveranditwill autoconnectafterpower on.31 +CPL03-LB is powered by (% style="color:blue" %)**8500mAh Li-SOCI2 battery**(%%), it is designed for long term use up to 5 years. 34 34 33 +Each CPL03-LB is pre-load with a set of unique keys for LoRaWAN registrations, register these keys to local LoRaWAN server and it will auto connect after power on. 35 35 35 + 36 36 == 1.2 Features == 37 37 38 38 39 39 * LoRaWAN 1.0.3 Class A 40 +* Bands: CN470/EU433/KR920/US915/EU868/AS923/AU915/IN865 40 40 * Ultra-low power consumption 41 -* External3 meters SHT31 probe (For S31-LB)42 -* Measurerange -55°C ~~ 125°C42 +* Open/Close detect 43 +* Open/Close statistics 43 43 * Temperature & Humidity alarm 44 -* Bands: CN470/EU433/KR920/US915/EU868/AS923/AU915/IN865 45 +* supports open alarm feature 46 +* supports Datalog feature 45 45 * Support Bluetooth v5.1 and LoRaWAN remote configure 46 46 * Support wireless OTA update firmware 47 -* Uplink on periodically 49 +* Uplink on periodically and open/close event 48 48 * Downlink to change configure 49 49 * 8500mAh Battery for long term use 50 50 ... ... @@ -56,20 +56,6 @@ 56 56 * Supply Voltage: built in 8500mAh Li-SOCI2 battery , 2.5v ~~ 3.6v 57 57 * Operating Temperature: -40 ~~ 85°C 58 58 59 -(% style="color:#037691" %)**Temperature Sensor:** 60 - 61 -* Range: -40 to + 80°C 62 -* Accuracy: ±0.2 @ 0-90 °C 63 -* Resolution: 0.1°C 64 -* Long Term Shift: <0.03 °C/yr 65 - 66 -(% style="color:#037691" %)**Humidity Sensor: ** 67 - 68 -* Range: 0 ~~ 99.9% RH 69 -* Accuracy: ± 2%RH ( 0 ~~ 100%RH) 70 -* Resolution: 0.01% RH 71 -* Long Term Shift: <0.25 %RH/yr 72 - 73 73 (% style="color:#037691" %)**LoRa Spec:** 74 74 75 75 * Frequency Range, Band 1 (HF): 862 ~~ 1020 Mhz ... ... @@ -90,9 +90,16 @@ 90 90 * Sleep Mode: 5uA @ 3.3v 91 91 * LoRa Transmit Mode: 125mA @ 20dBm, 82mA @ 14dBm 92 92 93 -== 1.4 Sleepmodeand workingmode==81 +== 1.4 Applications == 94 94 95 95 84 +* Open/Close Detection 85 +* Pulse meter application 86 +* Dry Contact Detection 87 + 88 +== 1.5 Sleep mode and working mode == 89 + 90 + 96 96 (% style="color:blue" %)**Deep Sleep Mode: **(%%)Sensor doesn't have any LoRaWAN activate. This mode is used for storage and shipping to save battery life. 97 97 98 98 (% style="color:blue" %)**Working Mode:** (%%)In this mode, Sensor will work as LoRaWAN Sensor to Join LoRaWAN network and send out sensor data to server. Between each sampling/tx/rx periodically, sensor will be in IDLE mode), in IDLE mode, sensor has the same power consumption as Deep Sleep mode. ... ... @@ -120,7 +120,7 @@ 120 120 == 1.6 BLE connection == 121 121 122 122 123 - S31x-LB support BLE remote configure.118 +CPL03-LB support BLE remote configure. 124 124 125 125 126 126 BLE can be used to configure the parameter of sensor or see the console output from sensor. BLE will be only activate on below case: ... ... @@ -137,35 +137,9 @@ 137 137 [[image:image-20230523174230-1.png]] 138 138 139 139 140 -== 1.8 HardwareVariant==135 +== 1.8 Mechanical == 141 141 142 142 143 -(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:510px" %) 144 -|=(% style="width: 102px;background-color:#D9E2F3;color:#0070C0" %)Model|=(% style="width: 190px;background-color:#D9E2F3;color:#0070C0" %)Photo|=(% style="width: 218px;background-color:#D9E2F3;color:#0070C0" %)Probe Info 145 -|(% style="width:102px" %)((( 146 -S31-LB 147 -)))|(% style="width:190px" %)[[image:S31.jpg]]|(% style="width:297px" %)((( 148 -1 x SHT31 Probe 149 - 150 -Cable Length : 2 meters 151 - 152 - 153 -))) 154 -|(% style="width:102px" %)((( 155 -S31B-LB 156 -)))|(% style="width:190px" %)[[image:S31B.jpg]]|(% style="width:297px" %)((( 157 -1 x SHT31 Probe 158 - 159 -Installed in device. 160 -))) 161 - 162 -(% style="display:none" %) 163 - 164 - 165 - 166 -== 1.9 Mechanical == 167 - 168 - 169 169 [[image:Main.User Manual for LoRaWAN End Nodes.D20-LBD22-LBD23-LB_LoRaWAN_Temperature_Sensor_User_Manual.WebHome@1675143884058-338.png]] 170 170 171 171 ... ... @@ -175,12 +175,12 @@ 175 175 [[image:Main.User Manual for LoRaWAN End Nodes.D20-LBD22-LBD23-LB_LoRaWAN_Temperature_Sensor_User_Manual.WebHome@1675143909447-639.png]] 176 176 177 177 178 -= 2. Configure S31x-LB to connect to LoRaWAN network =147 += 2. Configure CPL03-LB to connect to LoRaWAN network = 179 179 180 180 == 2.1 How it works == 181 181 182 182 183 -The S31x-LB is configured as (% style="color:#037691" %)**LoRaWAN OTAA Class A**(%%) mode by default. It has OTAA keys to join LoRaWAN network. To connect a local LoRaWAN network, you need to input the OTAA keys in the LoRaWAN IoT server and press the button to activate theS31x-LB. It will automatically join the network via OTAA and start to send the sensor value. The default uplink interval is 20 minutes.152 +The CPL03-LB is configured as (% style="color:#037691" %)**LoRaWAN OTAA Class A**(%%) mode by default. It has OTAA keys to join LoRaWAN network. To connect a local LoRaWAN network, you need to input the OTAA keys in the LoRaWAN IoT server and press the button to activate the CPL03-LB. It will automatically join the network via OTAA and start to send the sensor value. The default uplink interval is 20 minutes. 184 184 185 185 186 186 == 2.2 Quick guide to connect to LoRaWAN server (OTAA) == ... ... @@ -188,12 +188,12 @@ 188 188 189 189 Following is an example for how to join the [[TTN v3 LoRaWAN Network>>url:https://console.cloud.thethings.network/]]. Below is the network structure; we use the [[LPS8v2>>url:https://www.dragino.com/products/lora-lorawan-gateway/item/228-lps8v2.html]] as a LoRaWAN gateway in this example. 190 190 191 -The LPS8 V2 is already set to connected to [[TTN network >>url:https://console.cloud.thethings.network/]], so what we need to now is configure the TTN server.160 +The LPS8v2 is already set to connected to [[TTN network >>url:https://console.cloud.thethings.network/]], so what we need to now is configure the TTN server. 192 192 193 193 194 -(% style="color:blue" %)**Step 1:**(%%) Create a device in TTN with the OTAA keys from S31x-LB.163 +(% style="color:blue" %)**Step 1:**(%%) Create a device in TTN with the OTAA keys from CPL03-LB. 195 195 196 -Each S31x-LB is shipped with a sticker with the default device EUI as below:165 +Each CPL03-LB is shipped with a sticker with the default device EUI as below: 197 197 198 198 [[image:image-20230426084152-1.png||alt="图片-20230426084152-1.png" height="233" width="502"]] 199 199 ... ... @@ -222,10 +222,10 @@ 222 222 [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LSN50v2-S31-S31B%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20User%20Manual/WebHome/image-20220611161308-6.png?width=744&height=485&rev=1.1||alt="图片-20220611161308-6.png"]] 223 223 224 224 225 -(% style="color:blue" %)**Step 2:**(%%) Activate on S31x-LB194 +(% style="color:blue" %)**Step 2:**(%%) Activate on CPL03-LB 226 226 227 227 228 -Press the button for 5 seconds to activate the S31x-LB.197 +Press the button for 5 seconds to activate the CPL03-LB. 229 229 230 230 (% style="color:green" %)**Green led**(%%) will fast blink 5 times, device will enter (% style="color:blue" %)**OTA mode**(%%) for 3 seconds. And then start to JOIN LoRaWAN network. (% style="color:green" %)**Green led**(%%) will solidly turn on for 5 seconds after joined in network. 231 231 ... ... @@ -237,7 +237,7 @@ 237 237 === 2.3.1 Device Status, FPORT~=5 === 238 238 239 239 240 -Users can use the downlink command(**0x26 01**) to ask S31x-LB to send device configure detail, include device configure status.S31x-LB will uplink a payload via FPort=5 to server.209 +Users can use the downlink command(**0x26 01**) to ask CPL03-LB to send device configure detail, include device configure status. CPL03-LB will uplink a payload via FPort=5 to server. 241 241 242 242 The Payload format is as below. 243 243 ... ... @@ -249,10 +249,10 @@ 249 249 250 250 Example parse in TTNv3 251 251 252 -[[image:i mage-20230421171614-1.png||alt="图片-20230421171614-1.png"]]221 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/CPL01%20LoRaWAN%20Outdoor%20PulseContact%20%20Sensor%20Manual/WebHome/1652859749264-179.png?width=723&height=275&rev=1.1||alt="1652859749264-179.png"]] 253 253 254 254 255 -(% style="color:#037691" %)**Sensor Model**(%%): For S31x-LB, this value is 0x0A224 +(% style="color:#037691" %)**Sensor Model**(%%): For CPL03-LB, this value is 0x0A 256 256 257 257 (% style="color:#037691" %)**Firmware Version**(%%): 0x0100, Means: v1.0.0 version 258 258 ... ... @@ -305,229 +305,466 @@ 305 305 Ex2: 0x0B49 = 2889mV 306 306 307 307 308 -=== 2.3.2 Data.FPORT~=2===277 +=== 2.3.2 Sensor Configuration, FPORT~=4 === 309 309 310 310 311 - SensorDataisuplinkviaFPORT=2280 +CPL01 will only send this command after getting the downlink command (0x26 02) from the server. 312 312 313 -(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:500px" %) 314 -|=(% style="width: 90px;background-color:#D9E2F3" %)((( 315 -**Size(bytes)** 316 -)))|=(% style="width: 80px;background-color:#D9E2F3" %)2|=(% style="width: 90px;background-color:#D9E2F3" %)4|=(% style="width:80px;background-color:#D9E2F3" %)1|=(% style="width: 80px;background-color:#D9E2F3" %)**2**|=(% style="width: 80px;background-color:#D9E2F3" %)2 317 -|(% style="width:99px" %)**Value**|(% style="width:69px" %)((( 318 -[[Battery>>||anchor="HBattery"]] 319 -)))|(% style="width:130px" %)((( 320 -[[Unix TimeStamp>>||anchor="H2.5.2UnixTimeStamp"]] 321 -)))|(% style="width:91px" %)((( 322 -[[Alarm Flag>>||anchor="HAlarmFlag26MOD"]] 323 -)))|(% style="width:103px" %)((( 324 -[[Temperature>>||anchor="HTemperature"]] 325 -)))|(% style="width:80px" %)((( 326 -[[Humidity>>||anchor="HHumidity"]] 282 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %) 283 +|(% colspan="6" style="background-color:#d9e2f3; color:#0070c0; width:504px" %)**Sensor Configuration FPORT=4** 284 +|**Size(bytes)**|(% style="width:75px" %)**3**|(% style="width:77px" %)**1**|(% style="width:96px" %)**1**|(% style="width:158px" %)**2**|(% style="width:158px" %)**1** 285 +|**Value**|(% style="width:75px" %)TDC (unit:sec)|(% style="width:77px" %)Disalarm|(% style="width:96px" %)Keep status|(% style="width:158px" %)Keep time (unit: sec)|(% style="width:158px" %)Trigger mode 286 + 287 +* ((( 288 +(% style="color:#037691" %)** TDC: (default: 0x001C20)** 327 327 ))) 328 328 329 -==== (% style="color:#4472c4" %)**2.3.2.1 Battery**(%%) ==== 291 +((( 292 +Uplink interval for the total pulse count, default value is 0x001C20 which is 7200 seconds = 2 hours. 330 330 331 -Sensor Battery Level. 294 + 295 +))) 332 332 333 -Ex1: 0x0B45 = 2885mV 297 +* ((( 298 +(% style="color:#037691" %)** Disalarm: (default: 0)** 299 +))) 334 334 335 -Ex2: 0x0B49 = 2889mV 301 +((( 302 +(% style="color:blue" %)** If Disalarm = 1**(%%), CPL01 will only send uplink at every TDC periodically. This is normally use for pulse meter application, in this application, there are many disconnect/connect event, and platform only care about the total number of pulse. 303 +))) 336 336 305 +((( 306 +(% style="color:blue" %)** If Disalarm = 0**(%%), CPL01 will send uplink at every TDC periodically. 337 337 308 + 309 +))) 338 338 339 -==== (% style="color:#4472c4" %)**2.3.2.2 Temperature**(%%) ==== 311 +* ((( 312 +(% style="color:#037691" %)** Keep Status & Keep Time** 313 +))) 340 340 341 -**Example**: 315 +((( 316 +Shows the configure value of [[Alarm Base on Timeout Feature>>||anchor="H3.5AlarmBaseonTimeout"]] 342 342 343 -If payload is: 0105H: (0105 & 8000 == 0), temp = 0105H /10 = 26.1 degree 318 + 319 +))) 344 344 345 -If payload is: FF3FH : (FF3F & 8000 == 1) , temp = (FF3FH - 65536)/10 = -19.3 degrees. 321 +* ((( 322 +(% style="color:#037691" %)** Trigger mode (default: 0)** 323 +))) 346 346 347 -(FF3F & 8000:Judge whether the highest bit is 1, when the highest bit is 1, it is negative) 325 +((( 326 +(% style="color:blue" %)** If Trigger mode = 0**(%%), count close to open event. 327 +))) 348 348 329 +((( 330 +(% style="color:blue" %)** If Trigger mode = 1**(%%), count open to close event. 331 +))) 349 349 350 - ==== (% style="color:#4472c4" %)**2.3.2.3Humidity**(%%)====333 +[[image:1652860064987-743.png||height="152" width="730"]] 351 351 352 352 353 - Read:0x(0197)=412Value: 412/ 10=41.2, So 41.2%336 +[[image:1652860079526-831.png||height="209" width="729"]] 354 354 355 355 356 -=== =(% style="color:#4472c4" %)**2.3.2.4AlarmFlag&MOD**(%%)====339 +=== 2.3.3 Real-Time Open/Close Status, Uplink FPORT~=2 === 357 357 358 358 359 -**Example:** 342 +((( 343 +((( 344 +CPL01 will send this uplink **after** Device Status once join the LoRaWAN network successfully. And CPL01 will: 345 +))) 346 +))) 360 360 361 -If payload & 0x01 = 0x01 **~-~->** This is an Alarm Message 348 +((( 349 +((( 350 +periodically send this uplink every 2 hours, this interval [[can be changed>>||anchor="H3.1SetTransmitIntervalTime"]]. 351 +))) 352 +))) 362 362 363 -If payload & 0x01 = 0x00 **~-~->** This is a normal uplink message, no alarm 354 +((( 355 +((( 356 +Uplink Payload totals 11 bytes. 357 +))) 358 +))) 364 364 365 -If payload >> 2 = 0x00 **~-~->** means MOD=1, This is a sampling uplink message 360 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:520px" %) 361 +|=(% colspan="5" style="background-color:#D9E2F3;color:#0070C0; width: 520px;" %)**Real-Time Open/Close Status, FPORT=2** 362 +|(% style="width:60px" %)**Size(bytes)**|(% style="width:65px" %)**1**|(% style="width:65px" %)**3**|(% style="width:240px" %)**3**|(% style="width:90px" %)**4** 363 +|(% style="width:101px" %)**Value**|(% style="width:133px" %)Status & [[Alarm>>||anchor="H3.5AlarmBaseonTimeout"]]|(% style="width:92px" %)Total pulse|(% style="width:247px" %)The last open duration (unit: min)|(% style="width:149px" %)[[Unix TimeStamp>>||anchor="H2.4.1UnixTimeStamp"]] 366 366 367 -If payload >> 2 = 0x31 **~-~->** means MOD=31, this message is a reply message for polling, this message contains the alarm settings. see [[this link>>path:#HPolltheAlarmsettings:]] for detail. 365 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:504px" %) 366 +|=(% colspan="4" style="background-color:#D9E2F3;color:#0070C0; width: 502px;" %)**Status & Alarm field** 367 +|(% style="width:60px" %)**Size(bit)**|(% style="width:70px" %)**6**|(% style="width:228px" %)**1**|(% style="width:146px" %)**1** 368 +|(% style="width:76px" %)Value|(% style="width:80px" %)Calculate Flag|(% style="width:208px" %)Alarm: 0: No Alarm; 1: Alarm|(% style="width:136px" %)Contact Status: 0: Open, 1: Close 368 368 370 +* ((( 371 +(% style="color:#037691" %)** Calculate Flag** 372 +))) 369 369 370 -== 2.4 Payload Decoder file == 374 +((( 375 +The calculate flag is a user define field, IoT server can use this filed to handle different meter with different pulse factor. For example, if there are 100 water meters, meter 1 ~~50 are 1 liter/pulse and meter 51 ~~ 100 has 1.5 liter/pulse. 376 +))) 371 371 378 +((( 379 +User can set calculate flag to 1 for meter 1~~50 and 2 for meter 51 ~~ 100, So IoT Server can use this field for calculation. 380 +))) 372 372 373 -In TTN, use can add a custom payload so it shows friendly reading 382 +((( 383 +Default value: 0. 384 +))) 374 374 375 -In the page (% style="color:#037691" %)**Applications ~-~-> Payload Formats ~-~-> Custom ~-~-> decoder**(%%) to add the decoder from: 386 +((( 387 +Range (6 bits): (b)000000 ~~ (b) 111111 388 +))) 376 376 377 -[[https:~~/~~/github.com/dragino/dragino-end-node-decoder/tree/main/S31-LB%26S31B-LB>>https://github.com/dragino/dragino-end-node-decoder/tree/main/S31-LB%26S31B-LB]] 390 +((( 391 +Refer: [[Set Calculate Flag>>||anchor="H3.9Setthecalculateflag"]] 378 378 393 + 394 +))) 379 379 380 -== 2.5 Datalog Feature == 396 +* ((( 397 +(% style="color:#037691" %)** Alarm** 398 +))) 381 381 400 +((( 401 +See [[Alarm Base on Timeout>>||anchor="H3.5AlarmBaseonTimeout"]] 382 382 383 -Datalog Feature is to ensure IoT Server can get all sampling data from Sensor even if the LoRaWAN network is down. For each sampling, S31x-LB will store the reading for future retrieving purposes. 403 + 404 +))) 384 384 406 +* ((( 407 +(% style="color:#037691" %)** Contact Status** 408 +))) 385 385 386 -=== 2.5.1 Ways to get datalog via LoRaWAN === 410 +((( 411 +0: Open 412 +))) 387 387 414 +((( 415 +1: Close 388 388 389 -Set [[PNACKMD=1>>||anchor="H2.5.4DatalogUplinkpayload28FPORT3D329"]], S31x-LB will wait for ACK for every uplink, when there is no LoRaWAN network,S31x-LB will mark these records with non-ack messages and store the sensor data, and it will send all messages (10s interval) after the network recovery. 417 + 418 +))) 390 390 391 391 * ((( 392 - a)S31x-LB will do an ACK check for data recordssendingtomake sure every dataarriveserver.421 +(% style="color:#037691" %)** Total pulse** 393 393 ))) 423 + 424 +((( 425 +Total pulse/counting base on dry [[contact trigger event>>||anchor="H2.3.2SensorConfiguration2CFPORT3D4"]] 426 +))) 427 + 428 +((( 429 +Range (3 Bytes) : 0x000000 ~~ 0xFFFFFF . Max: 16777215 430 + 431 + 432 +))) 433 + 394 394 * ((( 395 - b)S31x-LB willsend data in **CONFIRMED Mode** when PNACKMD=1, but S31x-LBwon'tre-transmit thepacket if it doesn't get ACK, it will just mark it asa NONE-ACK message. In a futureuplink if S31x-LB gets a ACK, S31x-LB will considerthere isanetwork connectionand resend all NONE-ACK messages.435 +(% style="color:#037691" %)** The last open duration** 396 396 ))) 397 397 398 -Below is the typical case for the auto-update datalog feature (Set PNACKMD=1) 438 +((( 439 +Dry Contact last open duration. 440 +))) 399 399 400 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/WebHome/image-20220703111700-2.png?width=1119&height=381&rev=1.1||alt="图片-20220703111700-2.png" height="381" width="1119"]] 442 +((( 443 +Unit: min. 444 +))) 401 401 446 +[[image:1652860403792-491.png||height="153" width="735"]] 402 402 403 -=== 2.5.2 Unix TimeStamp === 404 404 449 +=== 2.3.4 Real-Time Open/Close Status, 3 pulse mode, Uplink FPORT~=6 === 405 405 406 -S31x-LB uses Unix TimeStamp format based on 407 407 408 - [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/WebHome/image-20220523001219-11.png?width=627&height=97&rev=1.1||alt="图片-20220523001219-11.png"height="97" width="627"]]452 +(% style="color:red" %)**Note:** 409 409 410 -User can get this time from link: [[https:~~/~~/www.epochconverter.com/>>url:https://www.epochconverter.com/]] : 454 +* Firmware support for this mode is not released. If users want to test, please contact Dragino support. 455 +* Users need to run (% style="color:blue" %)**AT+MOD=3**(%%) to support this model after updating the firmware. 456 +* This mode doesn't support Historical Events and Datalog features. 411 411 412 - Belowishenverterexample458 +(% style="color:blue" %)**CPL03-LB 3 Pulse Wiring:** 413 413 414 -[[image: http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/WebHome/image-20220523001219-12.png?width=720&height=298&rev=1.1||alt="图片-20220523001219-12.png"height="298" width="720"]]460 +[[image:image-20221013153352-1.png||height="628" width="720"]] 415 415 416 416 417 - So,we can useAT+TIMESTAMP=1611889405or downlink 3060137afd00 toset the currenttime 2021 – Jan ~-~- 29 Friday03:03:25463 +(% style="color:blue" %)**Payload:** 418 418 465 +[[image:image-20221013153352-2.png||height="167" width="1215"]] 419 419 420 -=== 2.5.3 Set Device Time === 421 421 468 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:447px" %) 469 +|(% style="background-color:#d9e2f3; color:#0070c0; width:95px" %)**Size(bytes)**|(% style="background-color:#d9e2f3; color:#0070c0; width:61px" %)**1**|(% style="background-color:#d9e2f3; color:#0070c0; width:98px" %)**3**|(% style="background-color:#d9e2f3; color:#0070c0; width:98px" %)**3**|(% style="background-color:#d9e2f3; color:#0070c0; width:95px" %)**3** 470 +|(% style="width:93px" %)Value|(% style="width:59px" %)Status|(% style="width:98px" %)((( 471 +Port1 Total Pulse(PB14) 472 +)))|(% style="width:96px" %)((( 473 +Port2 Total Pulse(PB15) 474 +)))|(% style="width:94px" %)((( 475 +Port3 Total Pulse(PA4) 476 +))) 422 422 423 - User need to set(% style="color:blue" %)**SYNCMOD=1**(%%)to enable synctime via MAC command.478 +(% style="color:blue" %)**Status:** 424 424 425 -Once S31x-LB Joined LoRaWAN network, it will send the MAC command (DeviceTimeReq) and the server will reply with (DeviceTimeAns) to send the current time to S31x-LB. If S31x-LB fails to get the time from the server, S31x-LB will use the internal time and wait for next time request (AT+SYNCTDC to set the time request period, default is 10 days). 480 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:257px" %) 481 +|(% style="background-color:#d9e2f3; color:#0070c0; width:75px" %)**Size(bit)**|(% style="background-color:#d9e2f3; color:#0070c0; width:112px" %)**6**|(% style="background-color:#d9e2f3; color:#0070c0; width:70px" %)**2** 482 +|(% style="width:75px" %)Value|(% style="width:111px" %)Calculate Flag|(% style="width:68px" %)Reserve 426 426 427 -(% style="color:red" %)** Note: LoRaWANServer need to support LoRaWANv1.0.3(MAC v1.0.3)orhigher to support this MAC command feature, Chirpstack,TTNV3 v3 and loriot supportbut TTN V3 v2 doesn'tsupport.If serverdoesn'tsupportthiscommand, it will through away uplink packet with this command, so user willlose the packet with timerequestforTTN V3 v2 if SYNCMOD=1.**484 +(% style="color:red" %)**Max COUNT for each port is 16777215. Exceed this number will reset to 1.** 428 428 429 429 430 - ===2.5.4 Datalog Uplinkpayload(FPORT~=3)===487 +(% style="color:blue" %)**Related AT Command:** 431 431 489 +(% style="color:#037691" %)**AT+TTRMOD1: Port1 count mode; 0: Signal falling edge(Default), 1: Signal raising edge** 432 432 433 -T heDatalog uplinkswill use below payloadformat.491 + AT+TTRMOD1=0 Downlink Command: 0xA4 01 00 434 434 435 - **Retrievaldatapayload:**493 + AT+TTRMOD1=1 Downlink Command: 0xA4 01 01 436 436 437 -(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:510px" %) 438 -|=(% style="width: 80px;background-color:#D9E2F3" %)((( 439 -**Size(bytes)** 440 -)))|=(% style="width: 60px; background-color: rgb(217, 226, 243);" %)**2**|=(% style="width: 60px; background-color: rgb(217, 226, 243);" %)**2**|=(% style="width: 120px; background-color: rgb(217, 226, 243);" %)**2**|=(% style="width: 103px; background-color: rgb(217, 226, 243);" %)**1**|=(% style="width: 85px; background-color: rgb(217, 226, 243);" %)**4** 441 -|(% style="width:103px" %)**Value**|(% style="width:54px" %)((( 442 -Temp_Black 443 -)))|(% style="width:51px" %)Temp_White|(% style="width:89px" %)Temp_ Red or Temp _White|(% style="width:103px" %)Poll message flag & Ext|(% style="width:54px" %)[[Unix Time Stamp>>||anchor="H2.5.2UnixTimeStamp"]] 444 444 445 -**Po llmessageflag& Ext:**496 +(% style="color:#037691" %)**AT+TTRMOD2: Port2 count mode; 0: Signal falling edge(Default), 1: Signal raising edge** 446 446 447 - [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/WebHome/image-20221006192726-1.png?width=754&height=112&rev=1.1||alt="图片-20221006192726-1.png" height="112" width="754"]]498 + AT+TTRMOD1=0 Downlink Command: 0xA4 02 00 448 448 449 - **NoACKMessage**:1:ThismessagemeansthispayloadisfromnUplinkMessagewhich doesn'tget ACK fromtheserverbefore ( for **PNACKMD=1** feature)500 + AT+TTRMOD1=1 Downlink Command: 0xA4 02 01 450 450 451 -**Poll Message Flag**: 1: This message is a poll message reply. 452 452 453 -* Poll MessageFlag isset to 1.503 +(% style="color:#037691" %)**AT+TTRMOD3: Port3 count mode; 0: Signal falling edge(Default), 1: Signal raising edge** 454 454 455 - *Eachdataentryis11bytes,tosaveairtimeandbattery,deviceswillsend max bytes accordingtothe current DRandFrequencybands.505 + AT+TTRMOD1=0 Downlink Command: 0xA4 03 00 456 456 457 - Forexample,inUS915band,themaxpayloadfordifferentDR is:507 + AT+TTRMOD1=1 Downlink Command: 0xA4 03 01 458 458 459 -**a) DR0:** max is 11 bytes so one entry of data 460 460 461 - **b)DR1:** max is53 bytes sodeviceswillupload 4 entriesof data(total44bytes)510 +(% style="color:#037691" %)**AT+CALCFLAG: Calculate Flag ( Default : 0 )** 462 462 463 - **c)DR2:**totalpayloadincludes11entriesofdata512 + AT+CALCFLAG=aa 464 464 465 -**d) DR3: **total payload includes 22 entries of data. 466 466 467 - Ifdevise doesn'thave anydata in thepolling time.Devicewill uplink11 bytesof0515 +(% style="color:blue" %)**Downlink Command: 0xA5 aa** 468 468 517 +(% style="color:#037691" %)**AT+COUNTMOD: Accumulative Mode; 0: Accumulative (Default),1: Reset after uplink.** 469 469 470 - **Example:**519 + AT+COUNTMOD=0 Downlink Command: 0x0B 00 471 471 472 - IfS31x-LBhasbelowdata insideFlash:521 + AT+COUNTMOD=1 Downlink Command: 0x0B 01 473 473 474 -[[image:1682646494051-944.png]] 475 475 476 - Ifusersendsbelowdownlinkcommand:3160065F9760066DA705524 +(% style="color:#037691" %)**AT+SETCNT: Set count value** 477 477 478 - Where:Starttime:60065F97=time21/1/1904:27:03526 + AT+SETCNT=1,aa Downlink Command: 0xA6 01 aa aa aa 479 479 480 - toptime:60066DA7=time 21/1/1905:27:03528 + AT+SETCNT=2,aa Downlink Command: 0xA6 02 aa aa aa 481 481 530 + AT+SETCNT=3,aa Downlink Command: 0xA6 03 aa aa aa 482 482 483 -**S31x-LB will uplink this payload.** 484 484 485 - [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/WebHome/image-20220523001219-13.png?width=727&height=421&rev=1.1||alt="图片-20220523001219-13.png" height="421" width="727"]]533 +(% style="color:blue" %)**Decode: **(%%)[[https:~~/~~/github.com/dragino/dragino-end-node-decoder>>https://github.com/dragino/dragino-end-node-decoder]] 486 486 535 + 536 +=== 2.3.5 Historical Door Open/Close Event, FPORT~=3 === 537 + 538 + 487 487 ((( 488 - __**7FFF089801464160065F97**__**__7FFF____088E____014B____41____60066009__**7FFF0885014E41600660667FFF0875015141600662BE7FFF086B015541600665167FFF08660155416006676E7FFF085F015A41600669C67FFF0857015D4160066C1E540 +CPL01 stores sensor values and users can retrieve these history values via the [[downlink command>>||anchor="H2.4DatalogFeature"]]. 489 489 ))) 490 490 491 491 ((( 492 - Wherethe first11 bytesisfor thefirstentry:544 +The historical payload includes one or multiplies entries and every entry has the same payload as Real-Time open/close status. 493 493 ))) 494 494 547 +* ((( 548 +Each data entry is 11 bytes and has the same structure as [[Real-Time open/close status>>||anchor="H2.3.3Real-TimeOpen2FCloseStatus2CUplinkFPORT3D2"]], to save airtime and battery, CPL01 will send max bytes according to the current DR and Frequency bands. 549 +))) 550 + 495 495 ((( 496 - 7FFF089801464160065F97552 +For example, in the US915 band, the max payload for different DR is: 497 497 ))) 498 498 499 499 ((( 500 -** Extsensor data**=0x7FFF/100=327.67556 +a) (% style="color:blue" %)**DR0**(%%): max is 11 bytes so one entry of data 501 501 ))) 502 502 503 503 ((( 504 -** Temp**=0x088E/100=22.00560 +b) (% style="color:blue" %)**DR1**(%%): max is 53 bytes so devices will upload 4 entries of data (total 44 bytes) 505 505 ))) 506 506 507 507 ((( 508 -** Hum**=0x014B/10=32.6564 +c) (% style="color:blue" %)**DR2**(%%): total payload includes 11 entries of data 509 509 ))) 510 510 511 511 ((( 512 - **pollmessageflag& Ext**=0x41,means replydata,Ext=1568 +d) (% style="color:blue" %)**DR3**(%%): total payload includes 22 entries of data. 513 513 ))) 514 514 515 515 ((( 516 -**Unix time** is 0x60066009=1611030423s=21/1/19 04:27:03 572 +If CPL01 doesn't have any data in the polling time. It will uplink 11 bytes of 0 573 + 574 + 517 517 ))) 518 518 577 +(% style="color:blue" %)** Downlink:** 519 519 520 -(% aria-label="数据 URI 图像图像小部件" contenteditable="false" role="region" style="background-image:url(http://wiki1.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" tabindex="-1" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||alt="数据 URI 图片" data-widget="image" draggable="true" height="15" role="presentation" title="单击并拖动以移动" width="15"]](% aria-label="数据 URI 图像图像小部件" contenteditable="false" role="region" style="background-image:url(http://wiki1.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220, 220, 220, 0.5); display:none" tabindex="-1" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||alt="数据 URI 图片" draggable="true" height="15" role="presentation" title="单击并拖动以移动" width="15"]](% aria-label="数据 URI 图像图像小部件" contenteditable="false" role="region" style="background-image:url(http://wiki1.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" tabindex="-1" title="单击并拖动以调整大小" %)的(% aria-label="数据 URI 图像图像小部件" contenteditable="false" role="region" style="background-image:url(http://wiki1.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" tabindex="-1" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||alt="数据 URI 图片" data-widget="image" draggable="true" height="15" role="presentation" title="单击并拖动以移动" width="15"]](% aria-label="数据 URI 图像图像小部件" contenteditable="false" role="region" style="background-image:url(http://wiki1.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220, 220, 220, 0.5); display:none" tabindex="-1" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||alt="数据 URI 图片" draggable="true" height="15" role="presentation" title="单击并拖动以移动" width="15"]](% aria-label="数据 URI 图像图像小部件" contenteditable="false" role="region" style="background-image:url(http://wiki1.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" tabindex="-1" title="单击并拖动以调整大小" %)的 579 +(% class="box" %) 580 +((( 581 +**0x31 61 E9 3A D4 61 E9 3D E0 05** 582 +))) 521 521 522 - ==2.6TemperatureAlarm Feature==584 +[[image:1652861353248-624.png||height="189" width="720"]] 523 523 524 524 525 - S31x-LBwork flow with Alarm feature.587 +(% style="color:blue" %)** Uplink:** 526 526 589 +(% class="box" %) 590 +((( 591 +**0E 00 23 E6 00 00 00 61 E9 3B 04 0E 00 23 E6 00 00 00 61 E9 3B 25 0D 00 00 00 00 00 00 61 E9 3B C8 0E 00 00 02 00 00 00 61 E9 3B D4 0E 00 00 06 00 00 00 61 E9 3B DB 01 00 00 00 00 00 00 61 E9 3C 91 01 00 00 00 00 00 00 61 E9 3C A1 0D 00 00 00 00 00 00 61 E9 3C BC 0E 00 00 07 00 00 00 61 E9 3C D6 00 00 00 00 00 00 00 61 E9 3D A6** 592 +))) 527 527 528 - [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LSN50v2-D20-D22-D23%20LoRaWAN%20Temperature%20Sensor%20User%20Manual/WebHome/image-20220623090437-1.png?rev=1.1||alt="图片-20220623090437-1.png"]]594 +(% style="color:#037691" %)** ** 529 529 596 +(% style="color:#037691" %)**Parsed Value:** 530 530 598 +((( 599 +[ALARM, PIN_STATUS, TOTAL_PULSE, CALCULATE_FLAG, LAST_OPEN_DURATION, TIME] 600 +))) 601 + 602 +((( 603 + 604 +))) 605 + 606 +((( 607 +[TRUE, CLOSE, 9190, 3, 0, 2022-01-20 10:35:48], 608 +))) 609 + 610 +((( 611 +[TRUE, CLOSE, 9190, 3, 0, 2022-01-20 10:36:21], 612 +))) 613 + 614 +((( 615 +[FALSE, OPEN, 0, 3, 0, 2022-01-20 10:39:04], 616 +))) 617 + 618 +((( 619 +[TRUE, CLOSE, 2, 3, 0, 2022-01-20 10:39:16], 620 +))) 621 + 622 +((( 623 +[TRUE, CLOSE, 6, 3, 0, 2022-01-20 10:39:23], 624 +))) 625 + 626 +((( 627 +[FALSE, OPEN, 0, 0, 0, 2022-01-20 10:42:25], 628 +))) 629 + 630 +((( 631 +[FALSE, OPEN, 0, 0, 0, 2022-01-20 10:42:41], 632 +))) 633 + 634 +((( 635 +[FALSE, OPEN, 0, 3, 0, 2022-01-20 10:43:08], 636 +))) 637 + 638 +((( 639 +[TRUE, CLOSE, 7, 3, 0, 2022-01-20 10:43:34], 640 +))) 641 + 642 +((( 643 +[FALSE, CLOSE, 0, 0, 0, 2022-01-20 10:47:02], 644 + 645 + 646 +))) 647 + 648 +[[image:1652861480446-216.png]] 649 + 650 + 651 +== 2.4 Payload Decoder file == 652 + 653 + 654 +In TTN, use can add a custom payload so it shows friendly reading 655 + 656 +In the page (% style="color:#037691" %)**Applications ~-~-> Payload Formats ~-~-> Custom ~-~-> decoder**(%%) to add the decoder from: [[https:~~/~~/github.com/dragino/dragino-end-node-decoder>>https://github.com/dragino/dragino-end-node-decoder]] 657 + 658 + 659 +== 2.5 Datalog Feature == 660 + 661 + 662 +Datalog Feature is to ensure IoT Server can get all sampling data from Sensor even if the LoRaWAN network is down. For each sampling, S31x-LB will store the reading for future retrieving purposes. 663 + 664 + 665 +=== 2.5.1 Ways to get datalog via LoRaWAN === 666 + 667 + 668 +Set [[PNACKMD=1>>||anchor="H2.5.4DatalogUplinkpayload28FPORT3D329"]], S31x-LB will wait for ACK for every uplink, when there is no LoRaWAN network,S31x-LB will mark these records with non-ack messages and store the sensor data, and it will send all messages (10s interval) after the network recovery. 669 + 670 +* ((( 671 +a) S31x-LB will do an ACK check for data records sending to make sure every data arrive server. 672 +))) 673 +* ((( 674 +b) S31x-LB will send data in **CONFIRMED Mode** when PNACKMD=1, but S31x-LB won't re-transmit the packet if it doesn't get ACK, it will just mark it as a NONE-ACK message. In a future uplink if S31x-LB gets a ACK, S31x-LB will consider there is a network connection and resend all NONE-ACK messages. 675 +))) 676 + 677 +Below is the typical case for the auto-update datalog feature (Set PNACKMD=1) 678 + 679 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/WebHome/image-20220703111700-2.png?width=1119&height=381&rev=1.1||alt="图片-20220703111700-2.png" height="381" width="1119"]] 680 + 681 + 682 +=== 2.5.2 Unix TimeStamp === 683 + 684 + 685 +S31x-LB uses Unix TimeStamp format based on 686 + 687 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/WebHome/image-20220523001219-11.png?width=627&height=97&rev=1.1||alt="图片-20220523001219-11.png" height="97" width="627"]] 688 + 689 +User can get this time from link: [[https:~~/~~/www.epochconverter.com/>>url:https://www.epochconverter.com/]] : 690 + 691 +Below is the converter example 692 + 693 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/WebHome/image-20220523001219-12.png?width=720&height=298&rev=1.1||alt="图片-20220523001219-12.png" height="298" width="720"]] 694 + 695 + 696 +So, we can use AT+TIMESTAMP=1611889405 or downlink 3060137afd00 to set the current time 2021 – Jan ~-~- 29 Friday 03:03:25 697 + 698 + 699 +=== 2.5.3 Set Device Time === 700 + 701 + 702 +User need to set (% style="color:blue" %)**SYNCMOD=1**(%%) to enable sync time via MAC command. 703 + 704 +Once S31x-LB Joined LoRaWAN network, it will send the MAC command (DeviceTimeReq) and the server will reply with (DeviceTimeAns) to send the current time to S31x-LB. If S31x-LB fails to get the time from the server, S31x-LB will use the internal time and wait for next time request (AT+SYNCTDC to set the time request period, default is 10 days). 705 + 706 +(% style="color:red" %)**Note: LoRaWAN Server need to support LoRaWAN v1.0.3(MAC v1.0.3) or higher to support this MAC command feature, Chirpstack,TTN V3 v3 and loriot support but TTN V3 v2 doesn't support. If server doesn't support this command, it will through away uplink packet with this command, so user will lose the packet with time request for TTN V3 v2 if SYNCMOD=1.** 707 + 708 + 709 + 710 +=== 2.5.4 Poll sensor value === 711 + 712 + 713 +Users can poll sensor values based on timestamps. Below is the downlink command. 714 + 715 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:425.818px" %) 716 +|(% colspan="4" style="background-color:#d9e2f3; color:#0070c0; width:423px" %)**Downlink Command to poll Open/Close status (0x31)** 717 +|(% style="width:58px" %)**1byte**|(% style="width:127px" %)**4bytes**|(% style="width:124px" %)**4bytes**|(% style="width:114px" %)**1byte** 718 +|(% style="width:58px" %)31|(% style="width:127px" %)Timestamp start|(% style="width:124px" %)Timestamp end|(% style="width:114px" %)Uplink Interval 719 + 720 +((( 721 +Timestamp start and Timestamp end-use Unix TimeStamp format as mentioned above. Devices will reply with all data logs during this period, using the uplink interval. 722 +))) 723 + 724 +((( 725 +For example, downlink command[[image:image-20220518162852-1.png]] 726 +))) 727 + 728 +((( 729 +Is to check 2021/11/12 12:00:00 to 2021/11/12 15:00:00's data 730 +))) 731 + 732 +((( 733 +Uplink Internal =5s,means CPL01 will send one packet every 5s. range 5~~255s. 734 +))) 735 + 736 + 531 531 == 2.7 Frequency Plans == 532 532 533 533 ... ... @@ -560,21 +560,27 @@ 560 560 [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/>>http://wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/]] 561 561 562 562 563 -== 3.3 Commands special design for S31x-LB ==769 +== 3.3 Commands special design for CPL03-LB == 564 564 565 565 566 -These commands only valid for S31x-LB, as below:772 +These commands only valid for CPL03-LB, as below: 567 567 568 568 569 569 === 3.3.1 Set Transmit Interval Time === 570 570 571 571 778 +((( 572 572 Feature: Change LoRaWAN End Node Transmit Interval. 573 573 781 + 782 +))) 783 + 784 +((( 574 574 (% style="color:blue" %)**AT Command: AT+TDC** 786 +))) 575 575 576 576 (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %) 577 -|=(% style="width: 156px;background-color:#D9E2F3" %)**Command Example**|=(% style="width: 137px;background-color:#D9E2F3" %)**Function**|=(% style="background-color:#D9E2F3" %)**Response** 789 +|=(% style="width: 156px;background-color:#D9E2F3; color:#0070c0" %)**Command Example**|=(% style="width: 137px;background-color:#D9E2F3; color:#0070c0" %)**Function**|=(% style="background-color:#D9E2F3; color:#0070c0" %)**Response** 578 578 |(% style="width:156px" %)AT+TDC=?|(% style="width:137px" %)Show current transmit Interval|((( 579 579 30000 580 580 OK ... ... @@ -585,18 +585,48 @@ 585 585 Set transmit interval to 60000ms = 60 seconds 586 586 ))) 587 587 800 +((( 588 588 (% style="color:blue" %)**Downlink Command: 0x01** 802 +))) 589 589 804 +((( 590 590 Format: Command Code (0x01) followed by 3 bytes time value. 806 +))) 591 591 808 +((( 592 592 If the downlink payload=0100003C, it means set the END Node's Transmit Interval to 0x00003C=60(S), while type code is 01. 810 +))) 593 593 594 -* Example 1: Downlink Payload: 0100001E ~/~/ Set Transmit Interval (TDC) = 30 seconds 595 -* Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds 812 +* ((( 813 +Example 1: Downlink Payload: 0100001E ~/~/ Set Transmit Interval (TDC) = 30 seconds 814 +))) 815 +* ((( 816 +Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds 596 596 597 -=== 3.3.2 Get Device Status === 598 598 819 + 820 +))) 599 599 822 + 823 +=== 3.3.2 Quit AT Command === 824 + 825 + 826 +Feature: Quit AT Command mode, so user needs to input the password again before using AT Commands. 827 + 828 +(% style="color:blue" %)**AT Command: AT+DISAT** 829 + 830 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:452px" %) 831 +|=(% style="width: 155px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 198px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 99px;background-color:#D9E2F3;color:#0070C0" %)**Response** 832 +|(% style="width:155px" %)AT+DISAT|(% style="width:198px" %)Quit AT Commands mode|(% style="width:96px" %)OK 833 + 834 +(% style="color:blue" %)**Downlink Command:** 835 + 836 +No downlink command for this feature. 837 + 838 + 839 +=== 3.3.3 Get Device Status === 840 + 841 + 600 600 Send a LoRaWAN downlink to ask device send Alarm settings. 601 601 602 602 (% style="color:blue" %)**Downlink Payload: **(%%)0x26 01 ... ... @@ -604,89 +604,260 @@ 604 604 Sensor will upload Device Status via FPORT=5. See payload section for detail. 605 605 606 606 607 -=== 3.3. 3SetTemperature AlarmThreshold===849 +=== 3.3.4 Enable / Disable Alarm === 608 608 609 609 610 - *(%style="color:blue"%)**ATCommand:**852 +Feature: Enable/Disable Alarm for open/close event. Default value 0. 611 611 612 -(% style="color: #037691" %)**AT+SHTEMP=min,max**854 +(% style="color:blue" %)**AT Command:** 613 613 614 -* When min=0, and max≠0, Alarm higher than max 615 -* When min≠0, and max=0, Alarm lower than min 616 -* When min≠0 and max≠0, Alarm higher than max or lower than min 856 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:520px" %) 857 +|(% style="background-color:#d9e2f3; color:#0070c0; width:154px" %)**Command Example**|(% style="background-color:#d9e2f3; color:#0070c0; width:278px" %)**Function**|(% style="background-color:#d9e2f3; color:#0070c0; width:88px" %)**Response** 858 +|(% style="width:154px" %)AT+DISALARM=1|(% style="width:278px" %)End node will only send packets in TDC time.|OK 859 +|(% style="width:154px" %)AT+DISALARM=0|(% style="width:278px" %)End node will send packets in TDC time or status change for door sensor|OK 617 617 618 - Example:861 +(% style="color:blue" %)**Downlink Command:** 619 619 620 - T+SHTEMP=0,30Alarmwhentemperaturehigher than 30.863 +**0xA7 01** ~/~/ Same As AT+DISALARM=1 621 621 622 -* (%style="color:blue" %)**DownlinkPayload:**865 +**0xA7 00 ** ~/~/ Same As AT+DISALARM=0 623 623 624 -(% style="color: #037691" %)**0x(0C01 001E)**~/~/SetAT+SHTEMP=0,30867 +(% style="color:red" %)**Notice, This command requires setting CPL01 to LDS03A Mode first. See **(%%)**"(% style="color:blue" %)3.7 Set the sensor mode"(%%)** 625 625 626 -(% style="color:red" %)**(note: 3^^rd^^ byte= 0x00 for low limit(not set), 4^^th^^ byte = 0x1E for high limit: 30)** 627 627 870 +=== 3.3.5 Alarm Base on Timeout === 628 628 629 -=== 3.3.4 Set Humidity Alarm Threshold === 630 630 873 +((( 874 +((( 875 +CPL01 can monitor the timeout for a status change, this feature can be used to monitor some events such as door opening too long etc. Related Parameters are: 631 631 632 -* (% style="color:blue" %)**AT Command:** 877 + 878 +))) 879 +))) 633 633 634 -(% style="color:#037691" %)**AT+SHHUM=min,max** 881 +((( 882 +((( 883 +(% style="color:#4f81bd" %)**1. Keep Status: Status to be monitor** 884 +))) 885 +))) 635 635 636 -* When min=0, and max≠0, Alarm higher than max 637 -* When min≠0, and max=0, Alarm lower than min 638 -* When min≠0 and max≠0, Alarm higher than max or lower than min 887 +((( 888 +((( 889 +Keep Status = 1: Monitor Close to Open event 890 +))) 891 +))) 639 639 640 -Example: 893 +((( 894 +((( 895 +Keep Status = 0: Monitor Open to Close event 641 641 642 - AT+SHHUM=70,0 ~/~/ Alarm when humidity lower than 70%. 897 + 898 +))) 899 +))) 643 643 644 -* (% style="color:blue" %)**Downlink Payload:** 901 +((( 902 +((( 903 +(% style="color:#4f81bd" %)**2. Keep Time: Timeout to send an Alarm** 904 +))) 905 +))) 645 645 646 -(% style="color:#037691" %)**0x(0C 02 46 00)**(%%) ~/~/ Set AT+SHTHUM=70,0 907 +((( 908 +((( 909 +Range 0 ~~ 65535(0xFFFF) seconds. 910 +))) 911 +))) 647 647 648 -(% style="color:red" %)**(note: 3^^rd^^ byte= 0x46 for low limit (70%), 4^^th^^ byte = 0x00 for high limit (not set))** 913 +((( 914 +((( 915 +If keep time = 0, Disable Alarm Base on Timeout feature. 916 +))) 917 +))) 649 649 919 +((( 920 +((( 921 +If keep time > 0, device will monitor the keep status event and send an alarm when status doesn’t change after timeout. 922 +))) 650 650 651 -=== 3.3.5 Set Alarm Interval === 924 +((( 925 + 926 +))) 927 +))) 652 652 929 +((( 930 +((( 931 +(% style="color:#4f81bd" %)**AT Command**(%%) to configure: 932 +))) 653 653 654 -The shortest time of two Alarm packet. (unit: min) 934 +((( 935 +(% style="color:blue" %)**AT+TTRIG=1,30**(%%) ~-~-> When the **Keep Status** change from connect to disconnect, and device remains in disconnect status for more than 30 seconds. CPL01 will send an uplink packet, the [[Alarm bit>>||anchor="H2.3.3Real-TimeOpen2FCloseStatus2CUplinkFPORT3D2"]] (the second bit of 1^^st^^ byte of payload) on this uplink packet is set to 1. 936 +))) 655 655 656 -* (% style="color:blue" %)**AT Command:** 938 +((( 939 +(% style="color:blue" %)**AT+TTIG=0,0 **(%%) ~-~-> Default Value, disable timeout Alarm. 940 +))) 941 +))) 657 657 658 -(% style="color:#037691" %)**AT+ATDC=30** (%%) ~/~/ The shortest interval of two Alarm packets is 30 minutes, Means is there is an alarm packet uplink, there won't be another one in the next 30 minutes. 943 +((( 944 + 945 +))) 659 659 660 -* (% style="color:blue" %)**Downlink Payload:** 947 +((( 948 +((( 949 +(% style="color:#4f81bd" %)**Downlink Command**(%%) to configure: 950 +))) 661 661 662 -(% style="color:#037691" %)**0x(0D 00 1E)**(%%) **~-~--> ** Set AT+ATDC=0x 00 1E = 30 minutes 952 +((( 953 +**Command: 0xA9 aa bb cc** 954 +))) 955 +))) 663 663 957 +((( 958 +((( 959 +A9: Command Type Code 960 +))) 961 +))) 664 664 665 -=== 3.3.6 Get Alarm settings === 963 +((( 964 +((( 965 +aa: status to be monitored 966 +))) 967 +))) 666 666 969 +((( 970 +((( 971 +bb cc: timeout. 972 +))) 973 +))) 667 667 668 -Send a LoRaWAN downlink to ask device send Alarm settings. 975 +((( 976 + 977 +))) 669 669 670 -* (% style="color:#037691" %)**Downlink Payload: **(%%)0x0E 01 979 +((( 980 +((( 981 +If user send 0xA9 01 00 1E: equal to AT+TTRIG=1,30 982 +))) 983 +))) 671 671 672 -**Example:** 985 +((( 986 +((( 987 +Or 988 +))) 989 +))) 673 673 674 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LSN50v2-D20-D22-D23%20LoRaWAN%20Temperature%20Sensor%20User%20Manual/WebHome/1655948182791-225.png?rev=1.1||alt="1655948182791-225.png"]] 991 +((( 992 +((( 993 +0xA9 00 00 00: Equal to AT+TTRIG=0,0. Disable timeout Alarm. 994 +))) 995 +))) 675 675 676 676 677 - **Explain:**998 +=== 3.3.6 Clear Flash Record === 678 678 679 -* Alarm & MOD bit is 0x7C, 0x7C >> 2 = 0x31: Means this message is the Alarm settings message. 680 680 681 - === 3.3.7 SetInterruptMode===1001 +Feature: Clear flash storage for data log feature. 682 682 683 683 1004 +(% style="color:#4f81bd" %)**AT Command: AT+CLRDTA** 1005 + 1006 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:500px" %) 1007 +|=(% style="width: 157px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 169px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 174px;background-color:#D9E2F3;color:#0070C0" %)**Response** 1008 +|(% style="width:157px" %)AT+CLRDTA|(% style="width:169px" %)Clear flash storage for data log feature.|Clear all stored sensor data… OK 1009 + 1010 +((( 1011 +((( 1012 +(% style="color:#4f81bd" %)**Downlink Command:** 1013 +))) 1014 + 1015 +((( 1016 +* **Example**: 0xA301 ~/~/ Same as AT+CLRDTA 1017 +))) 1018 +))) 1019 + 1020 + 1021 + 1022 +=== 3.3.7 Set trigger mode === 1023 + 1024 + 1025 +Feature: Set the trigger interrupt mode. 1026 + 1027 +(% style="color:#4f81bd" %)**AT Command: AT+TTRMOD** 1028 + 1029 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:495px" %) 1030 +|=(% style="width: 157px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 246px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 92px;background-color:#D9E2F3;color:#0070C0" %)**Response** 1031 +|(% style="width:157px" %)((( 1032 +AT+TTRMOD=1 1033 +)))|(% style="width:156px" %)Count and trigger from open to close (rising edge)|(% style="width:89px" %)((( 1034 +((( 1035 +OK 1036 +))) 1037 +))) 1038 +|(% style="width:157px" %)((( 1039 +AT+TTRMOD=0 1040 +)))|(% style="width:156px" %)Count and trigger from close to open (falling edge)|(% style="width:89px" %)((( 1041 +OK 1042 +))) 1043 + 1044 +(% style="color:#4f81bd" %)**Downlink Command:** 1045 + 1046 +* **Example**: 0xA401 ~/~/ Same as AT+ TTRMOD =1 1047 + 1048 + 1049 + 1050 + 1051 + 1052 + 1053 +=== 3.3.8 Set the calculate flag === 1054 + 1055 + 1056 +Feature: Set the calculate flag 1057 + 1058 +(% style="color:#4f81bd" %)**AT Command: AT+CALCFLAG** 1059 + 1060 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:461px" %) 1061 +|=(% style="width: 158px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 193px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 110px;background-color:#D9E2F3;color:#0070C0" %)**Response** 1062 +|(% style="width:158px" %)AT+CALCFLAG =1|(% style="width:192px" %)Set the calculate flag to 1.|(% style="width:109px" %)OK 1063 +|(% style="width:158px" %)AT+CALCFLAG =2|(% style="width:192px" %)Set the calculate flag to 2.|(% style="width:109px" %)OK 1064 + 1065 +(% style="color:#4f81bd" %)**Downlink Command:** 1066 + 1067 +* **Example**: 0XA501 ~/~/ Same as AT+CALCFLAG =1 1068 + 1069 + 1070 + 1071 + 1072 +=== 3.3.9 Set count number === 1073 + 1074 + 1075 +Feature: Manually set the count number 1076 + 1077 +(% style="color:#4f81bd" %)**AT Command: AT+SETCNT** 1078 + 1079 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:479px" %) 1080 +|=(% style="width: 160px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 223px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 96px;background-color:#D9E2F3;color:#0070C0" %)**Response** 1081 +|(% style="width:160px" %)AT+ SETCNT =0|(% style="width:221px" %)Set the count number to 0.|(% style="width:95px" %)OK 1082 +|(% style="width:160px" %)AT+ SETCNT =100|(% style="width:221px" %)Set the count number to 100.|(% style="width:95px" %)OK 1083 + 1084 +(% style="color:#4f81bd" %)**Downlink Command:** 1085 + 1086 +* **Example**: 0xA6000001 ~/~/ Same as AT+ SETCNT =1 1087 +* **Example**: 0xA6000064 ~/~/ Same as AT+ SETCNT =100 1088 + 1089 + 1090 + 1091 + 1092 +=== 3.3.10 Set Interrupt Mode === 1093 + 1094 + 684 684 Feature, Set Interrupt mode for PA8 of pin. 685 685 1097 +When AT+INTMOD=0 is set, PA8 is used as a digital input port. 1098 + 686 686 (% style="color:blue" %)**AT Command: AT+INTMOD** 687 687 688 688 (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %) 689 -|=(% style="width: 15 4px;background-color:#D9E2F3" %)**Command Example**|=(% style="width: 196px;background-color:#D9E2F3" %)**Function**|=(% style="width: 157px;background-color:#D9E2F3" %)**Response**1102 +|=(% style="width: 155px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 197px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 158px;background-color:#D9E2F3;color:#0070C0" %)**Response** 690 690 |(% style="width:154px" %)AT+INTMOD=?|(% style="width:196px" %)Show current interrupt mode|(% style="width:157px" %)((( 691 691 0 692 692 OK ... ... @@ -709,9 +709,14 @@ 709 709 * Example 1: Downlink Payload: 06000000 ~/~/ Turn off interrupt mode 710 710 * Example 2: Downlink Payload: 06000003 ~/~/ Set the interrupt mode to rising edge trigger 711 711 712 -=== 3.3.8 Set Power Output Duration === 713 713 714 714 1127 + 1128 + 1129 + 1130 +=== 3.3.11 Set Power Output Duration === 1131 + 1132 + 715 715 Control the output duration 5V . Before each sampling, device will 716 716 717 717 ~1. first enable the power output to external sensor, ... ... @@ -723,7 +723,7 @@ 723 723 (% style="color:blue" %)**AT Command: AT+5VT** 724 724 725 725 (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %) 726 -|=(% style="width: 15 4px;background-color:#D9E2F3" %)**Command Example**|=(% style="width: 196px;background-color:#D9E2F3" %)**Function**|=(% style="width: 157px;background-color:#D9E2F3" %)**Response**1144 +|=(% style="width: 155px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 197px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 158px;background-color:#D9E2F3;color:#0070C0" %)**Response** 727 727 |(% style="width:154px" %)AT+5VT=?|(% style="width:196px" %)Show 5V open time.|(% style="width:157px" %)0 (default) 728 728 OK 729 729 |(% style="width:154px" %)AT+5VT=500|(% style="width:196px" %)Close after a delay of 1000 milliseconds.|(% style="width:157px" %)OK
- image-20230524105433-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +121.4 KB - Content
- image-20230524105747-2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +223.2 KB - Content
- image-20230524110125-3.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +194.1 KB - Content
- image-20230524110211-4.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +110.1 KB - Content
- image-20230524114302-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +12.0 KB - Content
- image-20230524114654-2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +17.8 KB - Content
- image-20230524114826-3.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +82.3 KB - Content
- image-20230524144422-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +34.9 KB - Content
- image-20230524144456-2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +33.9 KB - Content
- image-20230527093155-1.jpeg
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +9.3 KB - Content
- image-20230527093214-2.jpeg
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +14.7 KB - Content
- image-20230530084138-1.jpeg
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +1.1 MB - Content
- image-20230530084608-2.jpeg
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +1.1 MB - Content