Last modified by Mengting Qiu on 2023/12/14 11:15

From version 38.1
edited by Ellie Zhang
on 2023/05/06 16:20
Change comment: There is no comment for this version
To version 62.5
edited by Xiaoling
on 2023/05/30 10:08
Change comment: There is no comment for this version

Summary

Details

Page properties
Title
... ... @@ -1,1 +1,1 @@
1 -S31-LB / S31B-LB LoRaWAN Outdoor Temperature & Humidity Sensor User Manual
1 +CPL03-LB -- LoRaWAN Pulse/Contact Sensor User Manual
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.Ellie
1 +XWiki.Xiaoling
Content
... ... @@ -1,9 +1,7 @@
1 1  (% style="text-align:center" %)
2 -[[image:S31-B.jpg]]
2 +[[image:image-20230530084608-2.jpeg||height="707" width="707"]]
3 3  
4 4  
5 -
6 -
7 7  **Table of Contents:**
8 8  
9 9  {{toc/}}
... ... @@ -15,36 +15,40 @@
15 15  
16 16  = 1. Introduction =
17 17  
18 -== 1.1 What is S31x-LB LoRaWAN Temperature & Humidity Sensor ==
16 +== 1.1 What is CPL03-LB LoRaWAN Pulse/Contact Sensor ==
19 19  
20 -The Dragino S31x-LB is a (% style="color:blue" %)**LoRaWAN Temperature and Humidity Sensor**(%%) for Internet of Things solution. It is used to measure the (% style="color:blue" %)**surrounding environment temperature and relative air humidity precisely**(%%), and then upload to IoT server via LoRaWAN wireless protocol.
21 21  
22 -The temperature & humidity sensor used in S31x-LB is SHT31, which is fully calibrated, linearized, and temperature compensated digital output from Sensirion, it provides a strong reliability and long-term stability. The SHT31 is fixed in a (% style="color:blue" %)**waterproof anti-condensation casing**(%%) for long term use.
19 +The Dragino CPL03-LB is a (% style="color:blue" %)**LoRaWAN Contact Sensor**(%%) for Internet of Things solution. It detects dry contact status, open time, open counts, and then upload to IoT server via LoRaWAN wireless protocol.
23 23  
24 -The LoRa wireless technology used in S31x-LB allows device to send data and reach extremely long ranges at low data-rates. It provides ultra-long range spread spectrum communication and high interference immunity whilst minimizing current consumption.
21 +The CPL03-LB will send periodically data every day as well as for each dry contact action. It also counts the contact open times and calculate last open duration. User can also disable the uplink for each open/close event, instead, device can count each open event and uplink periodically.
25 25  
26 -S31x-LB supports (% style="color:blue" %)**Temperature & Humdity alarm feature**(%%), user can set temperature alarm for instant notice. S31x-LB supports Datalog feature, it can save the data when there is no LoRaWAN network and uplink when network recover.
23 +The LoRa wireless technology used in CPL03-LB allows device to send data and reach extremely long ranges at low data-rates. It provides ultra-long range spread spectrum communication and high interference immunity whilst minimizing current consumption.
27 27  
28 -S31x-LB has max 3 probes which measure maximum 3 temperature points.
25 +CPL03-LB (% style="color:blue" %)**supports open alarm feature**(%%), user can set open alarm for instant notice. CPL03-LB (% style="color:blue" %)**supports Datalog feature**(%%), it can save the data when there is no LoRaWAN network and uplink when network recover.
29 29  
30 -S31x-LB (% style="color:blue" %)**supports BLE configure**(%%) and (% style="color:blue" %)**wireless OTA update**(%%) which make user easy to use.
27 +CPL03-LB is designed for outdoor use. It has a weatherproof enclosure and industrial level battery to work in low to high temperatures.
31 31  
32 -S31x-LB is powered by (% style="color:blue" %)**8500mAh Li-SOCI2 battery**(%%), it is designed for long term use up to 5 years.
29 +CPL03-LB (% style="color:blue" %)**supports BLE configure**(%%) and (% style="color:blue" %)**wireless OTA update**(%%) which make user easy to use.
33 33  
34 -Each S31x-LB is pre-load with a set of unique keys for LoRaWAN registrations, register these keys to local LoRaWAN server and it will auto connect after power on.
31 +CPL03-LB is powered by (% style="color:blue" %)**8500mAh Li-SOCI2 battery**(%%), it is designed for long term use up to 5 years.
35 35  
33 +Each CPL03-LB is pre-load with a set of unique keys for LoRaWAN registrations, register these keys to local LoRaWAN server and it will auto connect after power on.
36 36  
35 +
37 37  == 1.2 ​Features ==
38 38  
38 +
39 39  * LoRaWAN 1.0.3 Class A
40 +* Bands: CN470/EU433/KR920/US915/EU868/AS923/AU915/IN865
40 40  * Ultra-low power consumption
41 -* External 3 meters SHT31 probe (For S31-LB)
42 -* Measure range -55°C ~~ 125°C
42 +* Open/Close detect
43 +* Open/Close statistics
43 43  * Temperature & Humidity alarm
44 -* Bands: CN470/EU433/KR920/US915/EU868/AS923/AU915/IN865
45 +* supports open alarm feature
46 +* supports Datalog feature
45 45  * Support Bluetooth v5.1 and LoRaWAN remote configure
46 46  * Support wireless OTA update firmware
47 -* Uplink on periodically
49 +* Uplink on periodically and open/close event
48 48  * Downlink to change configure
49 49  * 8500mAh Battery for long term use
50 50  
... ... @@ -56,20 +56,6 @@
56 56  * Supply Voltage: built in 8500mAh Li-SOCI2 battery , 2.5v ~~ 3.6v
57 57  * Operating Temperature: -40 ~~ 85°C
58 58  
59 -(% style="color:#037691" %)**Temperature Sensor:**
60 -
61 -* Range: -40 to + 80°C
62 -* Accuracy: ±0.2 @ 0-90 °C
63 -* Resolution: 0.1°C
64 -* Long Term Shift: <0.03 °C/yr
65 -
66 -(% style="color:#037691" %)**Humidity Sensor: **
67 -
68 -* Range: 0 ~~ 99.9% RH
69 -* Accuracy: ± 2%RH ( 0 ~~ 100%RH)
70 -* Resolution: 0.01% RH
71 -* Long Term Shift: <0.25 %RH/yr
72 -
73 73  (% style="color:#037691" %)**LoRa Spec:**
74 74  
75 75  * Frequency Range,  Band 1 (HF): 862 ~~ 1020 Mhz
... ... @@ -90,9 +90,16 @@
90 90  * Sleep Mode: 5uA @ 3.3v
91 91  * LoRa Transmit Mode: 125mA @ 20dBm, 82mA @ 14dBm
92 92  
93 -== 1.4 Sleep mode and working mode ==
81 +== 1.4 Applications ==
94 94  
95 95  
84 +* Open/Close Detection
85 +* Pulse meter application
86 +* Dry Contact Detection
87 +
88 +== 1.5 Sleep mode and working mode ==
89 +
90 +
96 96  (% style="color:blue" %)**Deep Sleep Mode: **(%%)Sensor doesn't have any LoRaWAN activate. This mode is used for storage and shipping to save battery life.
97 97  
98 98  (% style="color:blue" %)**Working Mode:** (%%)In this mode, Sensor will work as LoRaWAN Sensor to Join LoRaWAN network and send out sensor data to server. Between each sampling/tx/rx periodically, sensor will be in IDLE mode), in IDLE mode, sensor has the same power consumption as Deep Sleep mode.
... ... @@ -117,11 +117,10 @@
117 117  )))
118 118  |(% style="width:167px" %)Fast press ACT 5 times.|(% style="width:117px" %)Deactivate Device|(% style="width:225px" %)(% style="color:red" %)**Red led**(%%) will solid on for 5 seconds. Means device is in Deep Sleep Mode.
119 119  
120 -
121 121  == 1.6 BLE connection ==
122 122  
123 123  
124 -S31x-LB support BLE remote configure.
118 +CPL03-LB support BLE remote configure.
125 125  
126 126  
127 127  BLE can be used to configure the parameter of sensor or see the console output from sensor. BLE will be only activate on below case:
... ... @@ -133,28 +133,11 @@
133 133  If there is no activity connection on BLE in 60 seconds, sensor will shut down BLE module to enter low power mode.
134 134  
135 135  
136 -== 1.7  Hardware Variant ==
130 +== 1.7 Pin Definitions ==
137 137  
132 +[[image:image-20230523174230-1.png]]
138 138  
139 -(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:510px" %)
140 -|=(% style="width: 102px;background-color:#D9E2F3;color:#0070C0" %)Model|=(% style="width: 190px;background-color:#D9E2F3;color:#0070C0" %)Photo|=(% style="width: 218px;background-color:#D9E2F3;color:#0070C0" %)Probe Info
141 -|(% style="width:102px" %)S31-LB|(% style="width:190px" %)[[image:S31.jpg]]|(% style="width:297px" %)(((
142 -1 x SHT31 Probe
143 143  
144 -Cable Length : 2 meters
145 -
146 -
147 -)))
148 -|(% style="width:102px" %)S31B-LB|(% style="width:190px" %)[[image:S31B.jpg]]|(% style="width:297px" %)(((
149 -1 x SHT31 Probe
150 -
151 -Installed in device.
152 -)))
153 -
154 -(% style="display:none" %)
155 -
156 -
157 -
158 158  == 1.8 Mechanical ==
159 159  
160 160  
... ... @@ -167,12 +167,12 @@
167 167  [[image:Main.User Manual for LoRaWAN End Nodes.D20-LBD22-LBD23-LB_LoRaWAN_Temperature_Sensor_User_Manual.WebHome@1675143909447-639.png]]
168 168  
169 169  
170 -= 2. Configure S31x-LB to connect to LoRaWAN network =
147 += 2. Configure CPL03-LB to connect to LoRaWAN network =
171 171  
172 172  == 2.1 How it works ==
173 173  
174 174  
175 -The S31x-LB is configured as (% style="color:#037691" %)**LoRaWAN OTAA Class A**(%%) mode by default. It has OTAA keys to join LoRaWAN network. To connect a local LoRaWAN network, you need to input the OTAA keys in the LoRaWAN IoT server and press the button to activate the S31x-LB. It will automatically join the network via OTAA and start to send the sensor value. The default uplink interval is 20 minutes.
152 +The CPL03-LB is configured as (% style="color:#037691" %)**LoRaWAN OTAA Class A**(%%) mode by default. It has OTAA keys to join LoRaWAN network. To connect a local LoRaWAN network, you need to input the OTAA keys in the LoRaWAN IoT server and press the button to activate the CPL03-LB. It will automatically join the network via OTAA and start to send the sensor value. The default uplink interval is 20 minutes.
176 176  
177 177  
178 178  == 2.2 ​Quick guide to connect to LoRaWAN server (OTAA) ==
... ... @@ -180,12 +180,12 @@
180 180  
181 181  Following is an example for how to join the [[TTN v3 LoRaWAN Network>>url:https://console.cloud.thethings.network/]]. Below is the network structure; we use the [[LPS8v2>>url:https://www.dragino.com/products/lora-lorawan-gateway/item/228-lps8v2.html]] as a LoRaWAN gateway in this example.
182 182  
183 -The LPS8V2 is already set to connected to [[TTN network >>url:https://console.cloud.thethings.network/]], so what we need to now is configure the TTN server.
160 +The LPS8v2 is already set to connected to [[TTN network >>url:https://console.cloud.thethings.network/]], so what we need to now is configure the TTN server.
184 184  
185 185  
186 -(% style="color:blue" %)**Step 1:**(%%) Create a device in TTN with the OTAA keys from S31x-LB.
163 +(% style="color:blue" %)**Step 1:**(%%) Create a device in TTN with the OTAA keys from CPL03-LB.
187 187  
188 -Each S31x-LB is shipped with a sticker with the default device EUI as below:
165 +Each CPL03-LB is shipped with a sticker with the default device EUI as below:
189 189  
190 190  [[image:image-20230426084152-1.png||alt="图片-20230426084152-1.png" height="233" width="502"]]
191 191  
... ... @@ -214,10 +214,10 @@
214 214  [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LSN50v2-S31-S31B%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20User%20Manual/WebHome/image-20220611161308-6.png?width=744&height=485&rev=1.1||alt="图片-20220611161308-6.png"]]
215 215  
216 216  
217 -(% style="color:blue" %)**Step 2:**(%%) Activate on S31x-LB
194 +(% style="color:blue" %)**Step 2:**(%%) Activate on CPL03-LB
218 218  
219 219  
220 -Press the button for 5 seconds to activate the S31x-LB.
197 +Press the button for 5 seconds to activate the CPL03-LB.
221 221  
222 222  (% style="color:green" %)**Green led**(%%) will fast blink 5 times, device will enter (% style="color:blue" %)**OTA mode**(%%) for 3 seconds. And then start to JOIN LoRaWAN network. (% style="color:green" %)**Green led**(%%) will solidly turn on for 5 seconds after joined in network.
223 223  
... ... @@ -229,7 +229,7 @@
229 229  === 2.3.1 Device Status, FPORT~=5 ===
230 230  
231 231  
232 -Users can use the downlink command(**0x26 01**) to ask S31x-LB to send device configure detail, include device configure status. S31x-LB will uplink a payload via FPort=5 to server.
209 +Users can use the downlink command(**0x26 01**) to ask CPL03-LB to send device configure detail, include device configure status. CPL03-LB will uplink a payload via FPort=5 to server.
233 233  
234 234  The Payload format is as below.
235 235  
... ... @@ -241,10 +241,10 @@
241 241  
242 242  Example parse in TTNv3
243 243  
244 -[[image:image-20230421171614-1.png||alt="图片-20230421171614-1.png"]]
221 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/CPL01%20LoRaWAN%20Outdoor%20PulseContact%20%20Sensor%20Manual/WebHome/1652859749264-179.png?width=723&height=275&rev=1.1||alt="1652859749264-179.png"]]
245 245  
246 246  
247 -(% style="color:#037691" %)**Sensor Model**(%%): For S31x-LB, this value is 0x0A
224 +(% style="color:#037691" %)**Sensor Model**(%%): For CPL03-LB, this value is 0x0A
248 248  
249 249  (% style="color:#037691" %)**Firmware Version**(%%): 0x0100, Means: v1.0.0 version
250 250  
... ... @@ -297,223 +297,466 @@
297 297  Ex2: 0x0B49 = 2889mV
298 298  
299 299  
300 -=== 2.3.2  Sensor Data. FPORT~=2 ===
277 +=== 2.3.2 Sensor Configuration, FPORT~=4 ===
301 301  
302 302  
303 -Sensor Data is uplink via FPORT=2
280 +CPL01 will only send this command after getting the downlink command (0x26 02) from the server.
304 304  
305 -(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:500px" %)
306 -|=(% style="width: 90px;background-color:#D9E2F3" %)(((
307 -**Size(bytes)**
308 -)))|=(% style="width: 80px;background-color:#D9E2F3" %)2|=(% style="width: 90px;background-color:#D9E2F3" %)4|=(% style="width:80px;background-color:#D9E2F3" %)1|=(% style="width: 80px;background-color:#D9E2F3" %)**2**|=(% style="width: 80px;background-color:#D9E2F3" %)2
309 -|(% style="width:99px" %)**Value**|(% style="width:69px" %)(((
310 -[[Battery>>||anchor="HBattery:"]]
311 -)))|(% style="width:130px" %)(((
312 -[[Unix TimeStamp>>||anchor="H2.5.2UnixTimeStamp"]]
313 -)))|(% style="width:91px" %)(((
314 -[[Alarm Flag>>||anchor="HAlarmFlag26MOD:"]]
315 -)))|(% style="width:103px" %)(((
316 -[[Temperature>>||anchor="HTemperature:"]]
317 -)))|(% style="width:80px" %)(((
318 -[[Humidity>>||anchor="HHumidity:"]]
282 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %)
283 +|(% colspan="6" style="background-color:#d9e2f3; color:#0070c0; width:504px" %)**Sensor Configuration FPORT=4**
284 +|**Size(bytes)**|(% style="width:75px" %)**3**|(% style="width:77px" %)**1**|(% style="width:96px" %)**1**|(% style="width:158px" %)**2**|(% style="width:158px" %)**1**
285 +|**Value**|(% style="width:75px" %)TDC (unit:sec)|(% style="width:77px" %)Disalarm|(% style="width:96px" %)Keep status|(% style="width:158px" %)Keep time (unit: sec)|(% style="width:158px" %)Trigger mode
286 +
287 +* (((
288 +(% style="color:#037691" %)** TDC: (default: 0x001C20)**
319 319  )))
320 320  
321 -==== (% style="color:#4472c4" %)**Battery**(%%) ====
291 +(((
292 +Uplink interval for the total pulse count, default value is 0x001C20 which is 7200 seconds = 2 hours.
322 322  
323 -Sensor Battery Level.
294 +
295 +)))
324 324  
325 -Ex1: 0x0B45 = 2885mV
297 +* (((
298 +(% style="color:#037691" %)** Disalarm: (default: 0)**
299 +)))
326 326  
327 -Ex2: 0x0B49 = 2889mV
301 +(((
302 +(% style="color:blue" %)** If Disalarm = 1**(%%), CPL01 will only send uplink at every TDC periodically. This is normally use for pulse meter application, in this application, there are many disconnect/connect event, and platform only care about the total number of pulse.
303 +)))
328 328  
305 +(((
306 +(% style="color:blue" %)** If Disalarm = 0**(%%), CPL01 will send uplink at every TDC periodically.
329 329  
308 +
309 +)))
330 330  
331 -==== (% style="color:#4472c4" %)**Temperature**(%%) ====
311 +* (((
312 +(% style="color:#037691" %)** Keep Status & Keep Time**
313 +)))
332 332  
333 -**Example**:
315 +(((
316 +Shows the configure value of [[Alarm Base on Timeout Feature>>||anchor="H3.5AlarmBaseonTimeout"]]
334 334  
335 -If payload is: 0105H:  (0105 & 8000 == 0), temp = 0105H /10 = 26.1 degree
318 +
319 +)))
336 336  
337 -If payload is: FF3FH :  (FF3F & 8000 == 1) , temp = (FF3FH - 65536)/10 = -19.3 degrees.
321 +* (((
322 +(% style="color:#037691" %)** Trigger mode (default: 0)**
323 +)))
338 338  
339 -(FF3F & 8000:Judge whether the highest bit is 1, when the highest bit is 1, it is negative)
325 +(((
326 +(% style="color:blue" %)** If Trigger mode = 0**(%%), count close to open event.
327 +)))
340 340  
329 +(((
330 +(% style="color:blue" %)** If Trigger mode = 1**(%%), count open to close event.
331 +)))
341 341  
342 -==== (% style="color:#4472c4" %)**Humidity**(%%) ====
333 +[[image:1652860064987-743.png||height="152" width="730"]]
343 343  
344 344  
345 -Read:0x(0197)=412    Value:  412 / 10=41.2, So 41.2%
336 +[[image:1652860079526-831.png||height="209" width="729"]]
346 346  
347 347  
348 -==== (% style="color:#4472c4" %)**Alarm Flag& MOD**(%%) ====
339 +=== 2.3.3 Real-Time Open/Close Status, Uplink FPORT~=2 ===
349 349  
350 350  
351 -**Example:**
342 +(((
343 +(((
344 +CPL01 will send this uplink **after** Device Status once join the LoRaWAN network successfully. And CPL01 will:
345 +)))
346 +)))
352 352  
353 -If payload & 0x01 = 0x01  **~-~->** This is an Alarm Message
348 +(((
349 +(((
350 +periodically send this uplink every 2 hours, this interval [[can be changed>>||anchor="H3.1SetTransmitIntervalTime"]].
351 +)))
352 +)))
354 354  
355 -If payload & 0x01 = 0x00  **~-~->** This is a normal uplink message, no alarm
354 +(((
355 +(((
356 +Uplink Payload totals 11 bytes.
357 +)))
358 +)))
356 356  
357 -If payload >> 2 = 0x00  **~-~->**  means MOD=1, This is a sampling uplink message
360 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:520px" %)
361 +|=(% colspan="5" style="background-color:#D9E2F3;color:#0070C0; width: 520px;" %)**Real-Time Open/Close Status, FPORT=2**
362 +|(% style="width:60px" %)**Size(bytes)**|(% style="width:65px" %)**1**|(% style="width:65px" %)**3**|(% style="width:240px" %)**3**|(% style="width:90px" %)**4**
363 +|(% style="width:101px" %)**Value**|(% style="width:133px" %)Status & [[Alarm>>||anchor="H3.5AlarmBaseonTimeout"]]|(% style="width:92px" %)Total pulse|(% style="width:247px" %)The last open duration (unit: min)|(% style="width:149px" %)[[Unix TimeStamp>>||anchor="H2.4.1UnixTimeStamp"]]
358 358  
359 -If payload >> 2 = 0x31  **~-~->**  means MOD=31, this message is a reply message for polling, this message contains the alarm settings. see [[this link>>path:#HPolltheAlarmsettings:]] for detail. 
365 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:504px" %)
366 +|=(% colspan="4" style="background-color:#D9E2F3;color:#0070C0; width: 502px;" %)**Status & Alarm field**
367 +|(% style="width:60px" %)**Size(bit)**|(% style="width:70px" %)**6**|(% style="width:228px" %)**1**|(% style="width:146px" %)**1**
368 +|(% style="width:76px" %)Value|(% style="width:80px" %)Calculate Flag|(% style="width:208px" %)Alarm: 0: No Alarm; 1: Alarm|(% style="width:136px" %)Contact Status: 0: Open, 1: Close
360 360  
370 +* (((
371 +(% style="color:#037691" %)** Calculate Flag**
372 +)))
361 361  
362 -== 2.4 Payload Decoder file ==
374 +(((
375 +The calculate flag is a user define field, IoT server can use this filed to handle different meter with different pulse factor. For example, if there are 100 water meters, meter 1 ~~50 are 1 liter/pulse and meter 51 ~~ 100 has 1.5 liter/pulse.
376 +)))
363 363  
378 +(((
379 +User can set calculate flag to 1 for meter 1~~50 and 2 for meter 51 ~~ 100, So IoT Server can use this field for calculation.
380 +)))
364 364  
365 -In TTN, use can add a custom payload so it shows friendly reading
382 +(((
383 +Default value: 0. 
384 +)))
366 366  
367 -In the page (% style="color:#037691" %)**Applications ~-~-> Payload Formats ~-~-> Custom ~-~-> decoder**(%%) to add the decoder from:
386 +(((
387 +Range (6 bits): (b)000000 ~~ (b) 111111
388 +)))
368 368  
369 -[[https:~~/~~/github.com/dragino/dragino-end-node-decoder/tree/main/LSN50v2-S31%26S31B >>https://github.com/dragino/dragino-end-node-decoder/tree/main/LSN50v2-S31%26S31B]]
390 +(((
391 +Refer: [[Set Calculate Flag>>||anchor="H3.9Setthecalculateflag"]]
370 370  
393 +
394 +)))
371 371  
372 -== 2.5 Datalog Feature ==
396 +* (((
397 +(% style="color:#037691" %)** Alarm**
398 +)))
373 373  
400 +(((
401 +See [[Alarm Base on Timeout>>||anchor="H3.5AlarmBaseonTimeout"]]
374 374  
375 -Datalog Feature is to ensure IoT Server can get all sampling data from Sensor even if the LoRaWAN network is down. For each sampling, S31x-LB will store the reading for future retrieving purposes.
403 +
404 +)))
376 376  
406 +* (((
407 +(% style="color:#037691" %)** Contact Status**
408 +)))
377 377  
378 -=== 2.5.1 Ways to get datalog via LoRaWAN ===
410 +(((
411 +0: Open
412 +)))
379 379  
414 +(((
415 +1: Close
380 380  
381 -Set [[PNACKMD=1>>||anchor="H2.5.4DatalogUplinkpayloadA028FPORT3D329"]], S31x-LB will wait for ACK for every uplink, when there is no LoRaWAN network,S31x-LB will mark these records with non-ack messages and store the sensor data, and it will send all messages (10s interval) after the network recovery.
417 +
418 +)))
382 382  
383 -* a) S31x-LB will do an ACK check for data records sending to make sure every data arrive server.
384 -* b) S31x-LB will send data in **CONFIRMED Mode** when PNACKMD=1, but S31x-LB won't re-transmit the packet if it doesn't get ACK, it will just mark it as a NONE-ACK message. In a future uplink if S31x-LB gets a ACK, S31x-LB will consider there is a network connection and resend all NONE-ACK messages.
420 +* (((
421 +(% style="color:#037691" %)** Total pulse**
422 +)))
385 385  
386 -Below is the typical case for the auto-update datalog feature (Set PNACKMD=1)
424 +(((
425 +Total pulse/counting base on dry [[contact trigger event>>||anchor="H2.3.2SensorConfiguration2CFPORT3D4"]]
426 +)))
387 387  
388 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/WebHome/image-20220703111700-2.png?width=1119&height=381&rev=1.1||alt="图片-20220703111700-2.png" height="381" width="1119"]]
428 +(((
429 +Range (3 Bytes) : 0x000000 ~~ 0xFFFFFF . Max: 16777215
389 389  
390 -=== 2.5.2 Unix TimeStamp ===
431 +
432 +)))
391 391  
434 +* (((
435 +(% style="color:#037691" %)** The last open duration**
436 +)))
392 392  
393 -S31x-LB uses Unix TimeStamp format based on
438 +(((
439 +Dry Contact last open duration.
440 +)))
394 394  
395 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/WebHome/image-20220523001219-11.png?width=627&height=97&rev=1.1||alt="图片-20220523001219-11.png" height="97" width="627"]]
442 +(((
443 +Unit: min.
444 +)))
396 396  
397 -User can get this time from link:  [[https:~~/~~/www.epochconverter.com/>>url:https://www.epochconverter.com/]] :
446 +[[image:1652860403792-491.png||height="153" width="735"]]
398 398  
399 -Below is the converter example
400 400  
401 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/WebHome/image-20220523001219-12.png?width=720&height=298&rev=1.1||alt="图片-20220523001219-12.png" height="298" width="720"]]
449 +=== 2.3.4 Real-Time Open/Close Status, 3 pulse mode, Uplink FPORT~=6 ===
402 402  
403 -So, we can use AT+TIMESTAMP=1611889405 or downlink 3060137afd00 to set the current time 2021 – Jan ~-~- 29 Friday 03:03:25
404 404  
452 +(% style="color:red" %)**Note:**
405 405  
406 -=== 2.5.3 Set Device Time ===
454 +* Firmware support for this mode is not released. If users want to test, please contact Dragino support.
455 +* Users need to run (% style="color:blue" %)**AT+MOD=3**(%%) to support this model after updating the firmware.
456 +* This mode doesn't support Historical Events and Datalog features.
407 407  
458 +(% style="color:blue" %)**CPL03-LB 3 Pulse Wiring:**
408 408  
409 -User need to set (% style="color:blue" %)**SYNCMOD=1**(%%) to enable sync time via MAC command.
460 +[[image:image-20221013153352-1.png||height="628" width="720"]]
410 410  
411 -Once S31x-LB Joined LoRaWAN network, it will send the MAC command (DeviceTimeReq) and the server will reply with (DeviceTimeAns) to send the current time to S31x-LB. If S31x-LB fails to get the time from the server, S31x-LB will use the internal time and wait for next time request (AT+SYNCTDC to set the time request period, default is 10 days).
412 412  
413 -(% style="color:red" %)**Note: LoRaWAN Server need to support LoRaWAN v1.0.3(MAC v1.0.3) or higher to support this MAC command feature, Chirpstack,TTN V3 v3 and loriot support but TTN V3 v2 doesn't support. If server doesn't support this command, it will through away uplink packet with this command, so user will lose the packet with time request for TTN V3 v2 if SYNCMOD=1.**
463 +(% style="color:blue" %)**Payload:**
414 414  
465 +[[image:image-20221013153352-2.png||height="167" width="1215"]]
415 415  
416 -=== 2.5.4 Datalog Uplink payload (FPORT~=3) ===
417 417  
468 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:447px" %)
469 +|(% style="background-color:#d9e2f3; color:#0070c0; width:95px" %)**Size(bytes)**|(% style="background-color:#d9e2f3; color:#0070c0; width:61px" %)**1**|(% style="background-color:#d9e2f3; color:#0070c0; width:98px" %)**3**|(% style="background-color:#d9e2f3; color:#0070c0; width:98px" %)**3**|(% style="background-color:#d9e2f3; color:#0070c0; width:95px" %)**3**
470 +|(% style="width:93px" %)Value|(% style="width:59px" %)Status|(% style="width:98px" %)(((
471 +Port1 Total Pulse(PB14)
472 +)))|(% style="width:96px" %)(((
473 +Port2 Total Pulse(PB15)
474 +)))|(% style="width:94px" %)(((
475 +Port3 Total Pulse(PA4)
476 +)))
418 418  
419 -The Datalog uplinks will use below payload format.
478 +(% style="color:blue" %)**Status:**
420 420  
421 -**Retrieval data payload:**
480 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:257px" %)
481 +|(% style="background-color:#d9e2f3; color:#0070c0; width:75px" %)**Size(bit)**|(% style="background-color:#d9e2f3; color:#0070c0; width:112px" %)**6**|(% style="background-color:#d9e2f3; color:#0070c0; width:70px" %)**2**
482 +|(% style="width:75px" %)Value|(% style="width:111px" %)Calculate Flag|(% style="width:68px" %)Reserve
422 422  
423 -(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:510px" %)
424 -|=(% style="width: 80px;background-color:#D9E2F3" %)(((
425 -**Size(bytes)**
426 -)))|=(% style="width: 60px; background-color: rgb(217, 226, 243);" %)**2**|=(% style="width: 60px; background-color: rgb(217, 226, 243);" %)**2**|=(% style="width: 120px; background-color: rgb(217, 226, 243);" %)**2**|=(% style="width: 103px; background-color: rgb(217, 226, 243);" %)**1**|=(% style="width: 85px; background-color: rgb(217, 226, 243);" %)**4**
427 -|(% style="width:103px" %)**Value**|(% style="width:54px" %)(((
428 -[[Temp_Black>>||anchor="HTemperatureBlack:"]]
429 -)))|(% style="width:51px" %)[[Temp_White>>||anchor="HTemperatureWhite:"]]|(% style="width:89px" %)[[Temp_ Red or Temp _White>>||anchor="HTemperatureREDorTemperatureWhite:"]]|(% style="width:103px" %)Poll message flag & Ext|(% style="width:54px" %)[[Unix Time Stamp>>||anchor="H2.5.2UnixTimeStamp"]]
484 +(% style="color:red" %)**Max COUNT for each port is 16777215. Exceed this number will reset to 1.**
430 430  
431 -**Poll message flag & Ext:**
432 432  
433 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/WebHome/image-20221006192726-1.png?width=754&height=112&rev=1.1||alt="图片-20221006192726-1.png" height="112" width="754"]]
487 +(% style="color:blue" %)**Related AT Command:**
434 434  
435 -**No ACK Message**:  1: This message means this payload is fromn Uplink Message which doesn't get ACK from the server before ( for **PNACKMD=1** feature)
489 +(% style="color:#037691" %)**AT+TTRMOD1Port1 count mode 0: Signal falling edge(Default), 1: Signal raising edge**
436 436  
437 -**Poll Message Flag**: 1: This message is a poll message reply.
491 + AT+TTRMOD1=0  Downlink Command: 0xA4 01 00
438 438  
439 -* Poll Message Flag is set to 1.
493 + AT+TTRMOD1=1  Downlink Command: 0xA4 01 01
440 440  
441 -* Each data entry is 11 bytes, to save airtime and battery, devices will send max bytes according to the current DR and Frequency bands.
442 442  
443 -For example, in US915 band, the max payload for different DR is:
496 +(% style="color:#037691" %)**AT+TTRMOD2:  Port2 count mode;  0: Signal falling edge(Default), 1: Signal raising edge**
444 444  
445 -**a) DR0:** max is 11 bytes so one entry of data
498 + AT+TTRMOD1=0  Downlink Command: 0xA4 02 00
446 446  
447 -**b) DR1:** max is 53 bytes so devices will upload 4 entries of data (total 44 bytes)
500 + AT+TTRMOD1=1  Downlink Command: 0xA4 02 01
448 448  
449 -**c) DR2:** total payload includes 11 entries of data
450 450  
451 -**d) DR3: **total payload includes 22 entries of data.
503 +(% style="color:#037691" %)**AT+TTRMOD3:  Port3 count mode;  0: Signal falling edge(Default), 1: Signal raising edge**
452 452  
453 -If devise doesn't have any data in the polling time. Device will uplink 11 bytes of 0   
505 + AT+TTRMOD1=0  Downlink Command: 0xA4 03 00
454 454  
507 + AT+TTRMOD1=1  Downlink Command: 0xA4 03 01
455 455  
456 -**Example:**
457 457  
458 -If S31x-LB has below data inside Flash:
510 +(% style="color:#037691" %)**AT+CALCFLAG:  Calculate Flag ( Default : 0 )**
459 459  
460 -[[image:1682646494051-944.png]]
512 + AT+CALCFLAG=aa
461 461  
462 -If user sends below downlink command: 3160065F9760066DA705
463 463  
464 -Where : Start time: 60065F97 = time 21/1/19 04:27:03
515 +(% style="color:blue" %)**Downlink Command: 0xA5 aa**
465 465  
466 - Stop time: 60066DA7= time 21/1/19 05:27:03
517 +(% style="color:#037691" %)**AT+COUNTMOD:  Accumulative Mode;  0: Accumulative (Default),1: Reset after uplink.**
467 467  
519 + AT+COUNTMOD=0 Downlink Command: 0x0B 00
468 468  
469 -**S31x-LB will uplink this payload.**
521 + AT+COUNTMOD=1 Downlink Command: 0x0B 01
470 470  
471 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/WebHome/image-20220523001219-13.png?width=727&height=421&rev=1.1||alt="图片-20220523001219-13.png" height="421" width="727"]]
472 472  
524 +(% style="color:#037691" %)**AT+SETCNT:  Set count value**
525 +
526 + AT+SETCNT=1,aa  Downlink Command: 0xA6 01 aa aa aa
527 +
528 + AT+SETCNT=2,aa  Downlink Command: 0xA6 02 aa aa aa
529 +
530 + AT+SETCNT=3,aa  Downlink Command: 0xA6 03 aa aa aa
531 +
532 +
533 +(% style="color:blue" %)**Decode:  **(%%)[[https:~~/~~/github.com/dragino/dragino-end-node-decoder>>https://github.com/dragino/dragino-end-node-decoder]]
534 +
535 +
536 +=== 2.3.5 Historical Door Open/Close Event, FPORT~=3 ===
537 +
538 +
473 473  (((
474 -__**7FFF089801464160065F97**__ **__7FFF__ __088E__ __014B__ __41__ __60066009__** 7FFF0885014E41600660667FFF0875015141600662BE7FFF086B015541600665167FFF08660155416006676E7FFF085F015A41600669C67FFF0857015D4160066C1E
540 +CPL01 stores sensor values and users can retrieve these history values via the [[downlink command>>||anchor="H2.4DatalogFeature"]].
475 475  )))
476 476  
477 477  (((
478 -Where the first 11 bytes is for the first entry:
544 +The historical payload includes one or multiplies entries and every entry has the same payload as Real-Time open/close status.
479 479  )))
480 480  
547 +* (((
548 +Each data entry is 11 bytes and has the same structure as [[Real-Time open/close status>>||anchor="H2.3.3Real-TimeOpen2FCloseStatus2CUplinkFPORT3D2"]], to save airtime and battery, CPL01 will send max bytes according to the current DR and Frequency bands.
549 +)))
550 +
481 481  (((
482 -7FFF089801464160065F97
552 +For example, in the US915 band, the max payload for different DR is:
483 483  )))
484 484  
485 485  (((
486 -**Ext sensor data**=0x7FFF/100=327.67
556 +a) (% style="color:blue" %)**DR0**(%%): max is 11 bytes so one entry of data
487 487  )))
488 488  
489 489  (((
490 -**Temp**=0x088E/100=22.00
560 +b) (% style="color:blue" %)**DR1**(%%): max is 53 bytes so devices will upload 4 entries of data (total 44 bytes)
491 491  )))
492 492  
493 493  (((
494 -**Hum**=0x014B/10=32.6
564 +c) (% style="color:blue" %)**DR2**(%%): total payload includes 11 entries of data
495 495  )))
496 496  
497 497  (((
498 -**poll message flag & Ext**=0x41,means reply data,Ext=1
568 +d) (% style="color:blue" %)**DR3**(%%): total payload includes 22 entries of data.
499 499  )))
500 500  
501 501  (((
502 -**Unix time** is 0x60066009=1611030423s=21/1/19 04:27:03
572 +If CPL01 doesn't have any data in the polling time. It will uplink 11 bytes of 0
573 +
574 +
503 503  )))
504 504  
577 +(% style="color:blue" %)** Downlink:**
505 505  
506 -(% aria-label="数据 URI 图像图像小部件" contenteditable="false" role="region" style="background-image:url(http://wiki1.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" tabindex="-1" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||alt="数据 URI 图片" data-widget="image" draggable="true" height="15" role="presentation" title="单击并拖动以移动" width="15"]](% aria-label="数据 URI 图像图像小部件" contenteditable="false" role="region" style="background-image:url(http://wiki1.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220, 220, 220, 0.5); display:none" tabindex="-1" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||alt="数据 URI 图片" draggable="true" height="15" role="presentation" title="单击并拖动以移动" width="15"]](% aria-label="数据 URI 图像图像小部件" contenteditable="false" role="region" style="background-image:url(http://wiki1.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" tabindex="-1" title="单击并拖动以调整大小" %)的(% aria-label="数据 URI 图像图像小部件" contenteditable="false" role="region" style="background-image:url(http://wiki1.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" tabindex="-1" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||alt="数据 URI 图片" data-widget="image" draggable="true" height="15" role="presentation" title="单击并拖动以移动" width="15"]](% aria-label="数据 URI 图像图像小部件" contenteditable="false" role="region" style="background-image:url(http://wiki1.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220, 220, 220, 0.5); display:none" tabindex="-1" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||alt="数据 URI 图片" draggable="true" height="15" role="presentation" title="单击并拖动以移动" width="15"]](% aria-label="数据 URI 图像图像小部件" contenteditable="false" role="region" style="background-image:url(http://wiki1.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" tabindex="-1" title="单击并拖动以调整大小" %)的
579 +(% class="box" %)
580 +(((
581 +**0x31 61 E9 3A D4 61 E9 3D E0 05**
582 +)))
507 507  
508 -== 2.6 Temperature Alarm Feature ==
584 +[[image:1652861353248-624.png||height="189" width="720"]]
509 509  
510 510  
511 -S31x-LB work flow with Alarm feature.
587 +(% style="color:blue" %)** Uplink:**
512 512  
589 +(% class="box" %)
590 +(((
591 +**0E 00 23 E6 00 00 00 61 E9 3B 04 0E 00 23 E6 00 00 00 61 E9 3B 25 0D 00 00 00 00 00 00 61 E9 3B C8 0E 00 00 02 00 00 00 61 E9 3B D4 0E 00 00 06 00 00 00 61 E9 3B DB 01 00 00 00 00 00 00 61 E9 3C 91 01 00 00 00 00 00 00 61 E9 3C A1 0D 00 00 00 00 00 00 61 E9 3C BC 0E 00 00 07 00 00 00 61 E9 3C D6 00 00 00 00 00 00 00 61 E9 3D A6**
592 +)))
513 513  
514 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LSN50v2-D20-D22-D23%20LoRaWAN%20Temperature%20Sensor%20User%20Manual/WebHome/image-20220623090437-1.png?rev=1.1||alt="图片-20220623090437-1.png"]]
594 +(% style="color:#037691" %)** **
515 515  
596 +(% style="color:#037691" %)**Parsed Value:**
516 516  
598 +(((
599 +[ALARM, PIN_STATUS, TOTAL_PULSE, CALCULATE_FLAG, LAST_OPEN_DURATION, TIME]
600 +)))
601 +
602 +(((
603 +
604 +)))
605 +
606 +(((
607 +[TRUE, CLOSE, 9190, 3, 0, 2022-01-20 10:35:48],
608 +)))
609 +
610 +(((
611 +[TRUE, CLOSE, 9190, 3, 0, 2022-01-20 10:36:21],
612 +)))
613 +
614 +(((
615 +[FALSE, OPEN, 0, 3, 0, 2022-01-20 10:39:04],
616 +)))
617 +
618 +(((
619 +[TRUE, CLOSE, 2, 3, 0, 2022-01-20 10:39:16],
620 +)))
621 +
622 +(((
623 +[TRUE, CLOSE, 6, 3, 0, 2022-01-20 10:39:23],
624 +)))
625 +
626 +(((
627 +[FALSE, OPEN, 0, 0, 0, 2022-01-20 10:42:25],
628 +)))
629 +
630 +(((
631 +[FALSE, OPEN, 0, 0, 0, 2022-01-20 10:42:41],
632 +)))
633 +
634 +(((
635 +[FALSE, OPEN, 0, 3, 0, 2022-01-20 10:43:08],
636 +)))
637 +
638 +(((
639 +[TRUE, CLOSE, 7, 3, 0, 2022-01-20 10:43:34],
640 +)))
641 +
642 +(((
643 +[FALSE, CLOSE, 0, 0, 0, 2022-01-20 10:47:02],
644 +
645 +
646 +)))
647 +
648 +[[image:1652861480446-216.png]]
649 +
650 +
651 +== 2.4 Payload Decoder file ==
652 +
653 +
654 +In TTN, use can add a custom payload so it shows friendly reading
655 +
656 +In the page (% style="color:#037691" %)**Applications ~-~-> Payload Formats ~-~-> Custom ~-~-> decoder**(%%) to add the decoder from: [[https:~~/~~/github.com/dragino/dragino-end-node-decoder>>https://github.com/dragino/dragino-end-node-decoder]]
657 +
658 +
659 +== 2.5 Datalog Feature ==
660 +
661 +
662 +Datalog Feature is to ensure IoT Server can get all sampling data from Sensor even if the LoRaWAN network is down. For each sampling, S31x-LB will store the reading for future retrieving purposes.
663 +
664 +
665 +=== 2.5.1 Ways to get datalog via LoRaWAN ===
666 +
667 +
668 +Set [[PNACKMD=1>>||anchor="H2.5.4DatalogUplinkpayload28FPORT3D329"]], S31x-LB will wait for ACK for every uplink, when there is no LoRaWAN network,S31x-LB will mark these records with non-ack messages and store the sensor data, and it will send all messages (10s interval) after the network recovery.
669 +
670 +* (((
671 +a) S31x-LB will do an ACK check for data records sending to make sure every data arrive server.
672 +)))
673 +* (((
674 +b) S31x-LB will send data in **CONFIRMED Mode** when PNACKMD=1, but S31x-LB won't re-transmit the packet if it doesn't get ACK, it will just mark it as a NONE-ACK message. In a future uplink if S31x-LB gets a ACK, S31x-LB will consider there is a network connection and resend all NONE-ACK messages.
675 +)))
676 +
677 +Below is the typical case for the auto-update datalog feature (Set PNACKMD=1)
678 +
679 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/WebHome/image-20220703111700-2.png?width=1119&height=381&rev=1.1||alt="图片-20220703111700-2.png" height="381" width="1119"]]
680 +
681 +
682 +=== 2.5.2 Unix TimeStamp ===
683 +
684 +
685 +S31x-LB uses Unix TimeStamp format based on
686 +
687 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/WebHome/image-20220523001219-11.png?width=627&height=97&rev=1.1||alt="图片-20220523001219-11.png" height="97" width="627"]]
688 +
689 +User can get this time from link:  [[https:~~/~~/www.epochconverter.com/>>url:https://www.epochconverter.com/]] :
690 +
691 +Below is the converter example
692 +
693 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/WebHome/image-20220523001219-12.png?width=720&height=298&rev=1.1||alt="图片-20220523001219-12.png" height="298" width="720"]]
694 +
695 +
696 +So, we can use AT+TIMESTAMP=1611889405 or downlink 3060137afd00 to set the current time 2021 – Jan ~-~- 29 Friday 03:03:25
697 +
698 +
699 +=== 2.5.3 Set Device Time ===
700 +
701 +
702 +User need to set (% style="color:blue" %)**SYNCMOD=1**(%%) to enable sync time via MAC command.
703 +
704 +Once S31x-LB Joined LoRaWAN network, it will send the MAC command (DeviceTimeReq) and the server will reply with (DeviceTimeAns) to send the current time to S31x-LB. If S31x-LB fails to get the time from the server, S31x-LB will use the internal time and wait for next time request (AT+SYNCTDC to set the time request period, default is 10 days).
705 +
706 +(% style="color:red" %)**Note: LoRaWAN Server need to support LoRaWAN v1.0.3(MAC v1.0.3) or higher to support this MAC command feature, Chirpstack,TTN V3 v3 and loriot support but TTN V3 v2 doesn't support. If server doesn't support this command, it will through away uplink packet with this command, so user will lose the packet with time request for TTN V3 v2 if SYNCMOD=1.**
707 +
708 +
709 +
710 +=== 2.5.4 Poll sensor value ===
711 +
712 +
713 +Users can poll sensor values based on timestamps. Below is the downlink command.
714 +
715 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:425.818px" %)
716 +|(% colspan="4" style="background-color:#d9e2f3; color:#0070c0; width:423px" %)**Downlink Command to poll Open/Close status (0x31)**
717 +|(% style="width:58px" %)**1byte**|(% style="width:127px" %)**4bytes**|(% style="width:124px" %)**4bytes**|(% style="width:114px" %)**1byte**
718 +|(% style="width:58px" %)31|(% style="width:127px" %)Timestamp start|(% style="width:124px" %)Timestamp end|(% style="width:114px" %)Uplink Interval
719 +
720 +(((
721 +Timestamp start and Timestamp end-use Unix TimeStamp format as mentioned above. Devices will reply with all data logs during this period, using the uplink interval.
722 +)))
723 +
724 +(((
725 +For example, downlink command[[image:image-20220518162852-1.png]]
726 +)))
727 +
728 +(((
729 +Is to check 2021/11/12 12:00:00 to 2021/11/12 15:00:00's data
730 +)))
731 +
732 +(((
733 +Uplink Internal =5s,means CPL01 will send one packet every 5s. range 5~~255s.
734 +)))
735 +
736 +
517 517  == 2.7 Frequency Plans ==
518 518  
519 519  
... ... @@ -546,21 +546,27 @@
546 546  [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/>>http://wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/]]
547 547  
548 548  
549 -== 3.3 Commands special design for S31x-LB ==
769 +== 3.3 Commands special design for CPL03-LB ==
550 550  
551 551  
552 -These commands only valid for S31x-LB, as below:
772 +These commands only valid for CPL03-LB, as below:
553 553  
554 554  
555 555  === 3.3.1 Set Transmit Interval Time ===
556 556  
557 557  
778 +(((
558 558  Feature: Change LoRaWAN End Node Transmit Interval.
559 559  
781 +
782 +)))
783 +
784 +(((
560 560  (% style="color:blue" %)**AT Command: AT+TDC**
786 +)))
561 561  
562 562  (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %)
563 -|=(% style="width: 156px;background-color:#D9E2F3" %)**Command Example**|=(% style="width: 137px;background-color:#D9E2F3" %)**Function**|=(% style="background-color:#D9E2F3" %)**Response**
789 +|=(% style="width: 156px;background-color:#D9E2F3; color:#0070c0" %)**Command Example**|=(% style="width: 137px;background-color:#D9E2F3; color:#0070c0" %)**Function**|=(% style="background-color:#D9E2F3; color:#0070c0" %)**Response**
564 564  |(% style="width:156px" %)AT+TDC=?|(% style="width:137px" %)Show current transmit Interval|(((
565 565  30000
566 566  OK
... ... @@ -571,18 +571,48 @@
571 571  Set transmit interval to 60000ms = 60 seconds
572 572  )))
573 573  
800 +(((
574 574  (% style="color:blue" %)**Downlink Command: 0x01**
802 +)))
575 575  
804 +(((
576 576  Format: Command Code (0x01) followed by 3 bytes time value.
806 +)))
577 577  
808 +(((
578 578  If the downlink payload=0100003C, it means set the END Node's Transmit Interval to 0x00003C=60(S), while type code is 01.
810 +)))
579 579  
580 -* Example 1: Downlink Payload: 0100001E  ~/~/  Set Transmit Interval (TDC) = 30 seconds
581 -* Example 2: Downlink Payload: 0100003C  ~/~/  Set Transmit Interval (TDC) = 60 seconds
812 +* (((
813 +Example 1: Downlink Payload: 0100001E  ~/~/ Set Transmit Interval (TDC) = 30 seconds
814 +)))
815 +* (((
816 +Example 2: Downlink Payload: 0100003C  ~/~/ Set Transmit Interval (TDC) = 60 seconds
582 582  
583 -=== 3.3.2 Get Device Status ===
584 584  
819 +
820 +)))
585 585  
822 +
823 +=== 3.3.2 Quit AT Command ===
824 +
825 +
826 +Feature: Quit AT Command mode, so user needs to input the password again before using AT Commands.
827 +
828 +(% style="color:blue" %)**AT Command: AT+DISAT**
829 +
830 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:452px" %)
831 +|=(% style="width: 155px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 198px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 99px;background-color:#D9E2F3;color:#0070C0" %)**Response**
832 +|(% style="width:155px" %)AT+DISAT|(% style="width:198px" %)Quit AT Commands mode|(% style="width:96px" %)OK
833 +
834 +(% style="color:blue" %)**Downlink Command:**
835 +
836 +No downlink command for this feature.
837 +
838 +
839 +=== 3.3.3 Get Device Status ===
840 +
841 +
586 586  Send a LoRaWAN downlink to ask device send Alarm settings.
587 587  
588 588  (% style="color:blue" %)**Downlink Payload:  **(%%)0x26 01
... ... @@ -590,86 +590,260 @@
590 590  Sensor will upload Device Status via FPORT=5. See payload section for detail.
591 591  
592 592  
593 -=== 3.3.3 Set Temperature Alarm Threshold ===
849 +=== 3.3.4 Enable / Disable Alarm ===
594 594  
595 -* (% style="color:blue" %)**AT Command:**
596 596  
597 -(% style="color:#037691" %)**AT+SHTEMP=min,max**
852 +Feature: Enable/Disable Alarm for open/close event. Default value 0.
598 598  
599 -* When min=0, and max≠0, Alarm higher than max
600 -* When min≠0, and max=0, Alarm lower than min
601 -* When min≠0 and max≠0, Alarm higher than max or lower than min
854 +(% style="color:blue" %)**AT Command:**
602 602  
603 -Example:
856 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:520px" %)
857 +|(% style="background-color:#d9e2f3; color:#0070c0; width:154px" %)**Command Example**|(% style="background-color:#d9e2f3; color:#0070c0; width:278px" %)**Function**|(% style="background-color:#d9e2f3; color:#0070c0; width:88px" %)**Response**
858 +|(% style="width:154px" %)AT+DISALARM=1|(% style="width:278px" %)End node will only send packets in TDC time.|OK
859 +|(% style="width:154px" %)AT+DISALARM=0|(% style="width:278px" %)End node will send packets in TDC time or status change for door sensor|OK
604 604  
605 - AT+SHTEMP=0,30   ~/~/ Alarm when temperature higher than 30.
861 +(% style="color:blue" %)**Downlink Command:**
606 606  
607 -* (% style="color:blue" %)**Downlink Payload:**
863 +**0xA7 01**  ~/~/  Same As AT+DISALARM=1
608 608  
609 -(% style="color:#037691" %)**0x(0C 01 00 1E)**  (%%) ~/~/ Set AT+SHTEMP=0,30
865 +**0xA7 00    ** ~/~/  Same As AT+DISALARM=0
610 610  
611 -(% style="color:red" %)**(note: 3^^rd^^ byte= 0x00 for low limit(not set), 4^^th^^ byte = 0x1E for high limit: 30)**
867 +(% style="color:red" %)**Notice, This command requires setting CPL01 to LDS03A Mode first. See **(%%)**"(% style="color:blue" %)3.7 Set the sensor mode"(%%)**
612 612  
613 613  
614 -=== 3.3.4 Set Humidity Alarm Threshold ===
870 +=== 3.3.5 Alarm Base on Timeout ===
615 615  
616 -* (% style="color:blue" %)**AT Command:**
617 617  
618 -(% style="color:#037691" %)**AT+SHHUM=min,max**
873 +(((
874 +(((
875 +CPL01 can monitor the timeout for a status change, this feature can be used to monitor some events such as door opening too long etc. Related Parameters are:
619 619  
620 -* When min=0, and max≠0, Alarm higher than max
621 -* When min≠0, and max=0, Alarm lower than min
622 -* When min≠0 and max≠0, Alarm higher than max or lower than min
877 +
878 +)))
879 +)))
623 623  
624 -Example:
881 +(((
882 +(((
883 +(% style="color:#4f81bd" %)**1. Keep Status: Status to be monitor**
884 +)))
885 +)))
625 625  
626 - AT+SHHUM=70,0  ~/~/ Alarm when humidity lower than 70%.
887 +(((
888 +(((
889 +Keep Status = 1: Monitor Close to Open event
890 +)))
891 +)))
627 627  
628 -* (% style="color:blue" %)**Downlink Payload:**
893 +(((
894 +(((
895 +Keep Status = 0: Monitor Open to Close event
629 629  
630 -(% style="color:#037691" %)**0x(0C 02 46 00)**(%%)  ~/~/ Set AT+SHTHUM=70,0
897 +
898 +)))
899 +)))
631 631  
632 -(% style="color:red" %)**(note: 3^^rd^^ byte= 0x46 for low limit (70%), 4^^th^^ byte = 0x00 for high limit (not set))**
901 +(((
902 +(((
903 +(% style="color:#4f81bd" %)**2. Keep Time: Timeout to send an Alarm**
904 +)))
905 +)))
633 633  
907 +(((
908 +(((
909 +Range 0 ~~ 65535(0xFFFF) seconds.
910 +)))
911 +)))
634 634  
635 -=== 3.3.5 Set Alarm Interval ===
913 +(((
914 +(((
915 +If keep time = 0, Disable Alarm Base on Timeout feature.
916 +)))
917 +)))
636 636  
637 -The shortest time of two Alarm packet. (unit: min)
919 +(((
920 +(((
921 +If keep time > 0, device will monitor the keep status event and send an alarm when status doesn’t change after timeout.
922 +)))
638 638  
639 -* (% style="color:blue" %)**AT Command:**
924 +(((
925 +
926 +)))
927 +)))
640 640  
641 -(% style="color:#037691" %)**AT+ATDC=30** (%%) ~/~/ The shortest interval of two Alarm packets is 30 minutes, Means is there is an alarm packet uplink, there won't be another one in the next 30 minutes.
929 +(((
930 +(((
931 +(% style="color:#4f81bd" %)**AT Command**(%%) to configure:
932 +)))
642 642  
643 -* (% style="color:blue" %)**Downlink Payload:**
934 +(((
935 +(% style="color:blue" %)**AT+TTRIG=1,30**(%%)  ~-~-> When the **Keep Status** change from connect to disconnect, and device remains in disconnect status for more than 30 seconds. CPL01 will send an uplink packet, the [[Alarm bit>>||anchor="H2.3.3Real-TimeOpen2FCloseStatus2CUplinkFPORT3D2"]] (the second bit of 1^^st^^ byte of payload) on this uplink packet is set to 1.
936 +)))
644 644  
645 -(% style="color:#037691" %)**0x(0D 00 1E)**(%%)     **~-~--> ** Set AT+ATDC=0x 00 1E = 30 minutes
938 +(((
939 +(% style="color:blue" %)**AT+TTIG=0,0 **(%%) ~-~-> Default Value, disable timeout Alarm.
940 +)))
941 +)))
646 646  
943 +(((
944 +
945 +)))
647 647  
648 -=== 3.3.6 Get Alarm settings ===
947 +(((
948 +(((
949 +(% style="color:#4f81bd" %)**Downlink Command**(%%) to configure:
950 +)))
649 649  
952 +(((
953 +**Command: 0xA9 aa bb cc**
954 +)))
955 +)))
650 650  
651 -Send a LoRaWAN downlink to ask device send Alarm settings.
957 +(((
958 +(((
959 +A9: Command Type Code
960 +)))
961 +)))
652 652  
653 -* (% style="color:#037691" %)**Downlink Payload:  **(%%)0x0E 01
963 +(((
964 +(((
965 +aa: status to be monitored
966 +)))
967 +)))
654 654  
655 -**Example:**
969 +(((
970 +(((
971 +bb cc: timeout.
972 +)))
973 +)))
656 656  
657 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LSN50v2-D20-D22-D23%20LoRaWAN%20Temperature%20Sensor%20User%20Manual/WebHome/1655948182791-225.png?rev=1.1||alt="1655948182791-225.png"]]
975 +(((
976 +
977 +)))
658 658  
979 +(((
980 +(((
981 +If user send 0xA9 01 00 1E: equal to AT+TTRIG=1,30
982 +)))
983 +)))
659 659  
660 -**Explain:**
985 +(((
986 +(((
987 +Or
988 +)))
989 +)))
661 661  
662 -* Alarm & MOD bit is 0x7C, 0x7C >> 2 = 0x31: Means this message is the Alarm settings message.
991 +(((
992 +(((
993 +0xA9 00 00 00: Equal to AT+TTRIG=0,0. Disable timeout Alarm.
994 +)))
995 +)))
663 663  
664 -=== 3.3.7 Set Interrupt Mode ===
665 665  
998 +=== 3.3.6 Clear Flash Record ===
666 666  
667 -Feature, Set Interrupt mode for GPIO_EXIT.
668 668  
1001 +Feature: Clear flash storage for data log feature.
1002 +
1003 +
1004 +(% style="color:#4f81bd" %)**AT Command: AT+CLRDTA**
1005 +
1006 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:500px" %)
1007 +|=(% style="width: 157px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 169px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 174px;background-color:#D9E2F3;color:#0070C0" %)**Response**
1008 +|(% style="width:157px" %)AT+CLRDTA|(% style="width:169px" %)Clear flash storage for data log feature.|Clear all stored sensor data… OK
1009 +
1010 +(((
1011 +(((
1012 +(% style="color:#4f81bd" %)**Downlink Command:**
1013 +)))
1014 +
1015 +(((
1016 +* **Example**: 0xA301  ~/~/  Same as AT+CLRDTA
1017 +)))
1018 +)))
1019 +
1020 +
1021 +
1022 +=== 3.3.7 Set trigger mode ===
1023 +
1024 +
1025 +Feature: Set the trigger interrupt mode.
1026 +
1027 +(% style="color:#4f81bd" %)**AT Command: AT+TTRMOD**
1028 +
1029 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:495px" %)
1030 +|=(% style="width: 157px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 246px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 92px;background-color:#D9E2F3;color:#0070C0" %)**Response**
1031 +|(% style="width:157px" %)(((
1032 +AT+TTRMOD=1
1033 +)))|(% style="width:156px" %)Count and trigger from open to close (rising edge)|(% style="width:89px" %)(((
1034 +(((
1035 +OK
1036 +)))
1037 +)))
1038 +|(% style="width:157px" %)(((
1039 +AT+TTRMOD=0
1040 +)))|(% style="width:156px" %)Count and trigger from close to open (falling edge)|(% style="width:89px" %)(((
1041 +OK
1042 +)))
1043 +
1044 +(% style="color:#4f81bd" %)**Downlink Command:**
1045 +
1046 +* **Example**: 0xA401  ~/~/  Same as AT+ TTRMOD =1
1047 +
1048 +
1049 +
1050 +
1051 +
1052 +
1053 +=== 3.3.8 Set the calculate flag ===
1054 +
1055 +
1056 +Feature: Set the calculate flag
1057 +
1058 +(% style="color:#4f81bd" %)**AT Command: AT+CALCFLAG**
1059 +
1060 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:461px" %)
1061 +|=(% style="width: 158px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 193px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 110px;background-color:#D9E2F3;color:#0070C0" %)**Response**
1062 +|(% style="width:158px" %)AT+CALCFLAG =1|(% style="width:192px" %)Set the calculate flag to 1.|(% style="width:109px" %)OK
1063 +|(% style="width:158px" %)AT+CALCFLAG =2|(% style="width:192px" %)Set the calculate flag to 2.|(% style="width:109px" %)OK
1064 +
1065 +(% style="color:#4f81bd" %)**Downlink Command:**
1066 +
1067 +* **Example**: 0XA501  ~/~/  Same as AT+CALCFLAG =1
1068 +
1069 +
1070 +
1071 +
1072 +=== 3.3.9 Set count number ===
1073 +
1074 +
1075 +Feature: Manually set the count number
1076 +
1077 +(% style="color:#4f81bd" %)**AT Command: AT+SETCNT**
1078 +
1079 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:479px" %)
1080 +|=(% style="width: 160px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 223px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 96px;background-color:#D9E2F3;color:#0070C0" %)**Response**
1081 +|(% style="width:160px" %)AT+ SETCNT =0|(% style="width:221px" %)Set the count number to 0.|(% style="width:95px" %)OK
1082 +|(% style="width:160px" %)AT+ SETCNT =100|(% style="width:221px" %)Set the count number to 100.|(% style="width:95px" %)OK
1083 +
1084 +(% style="color:#4f81bd" %)**Downlink Command:**
1085 +
1086 +* **Example**: 0xA6000001  ~/~/  Same as AT+ SETCNT =1
1087 +* **Example**: 0xA6000064  ~/~/  Same as AT+ SETCNT =100
1088 +
1089 +
1090 +
1091 +
1092 +=== 3.3.10 Set Interrupt Mode ===
1093 +
1094 +
1095 +Feature, Set Interrupt mode for PA8 of pin.
1096 +
1097 +When AT+INTMOD=0 is set, PA8 is used as a digital input port.
1098 +
669 669  (% style="color:blue" %)**AT Command: AT+INTMOD**
670 670  
671 671  (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %)
672 -|=(% style="width: 154px;background-color:#D9E2F3" %)**Command Example**|=(% style="width: 196px;background-color:#D9E2F3" %)**Function**|=(% style="width: 157px;background-color:#D9E2F3" %)**Response**
1102 +|=(% style="width: 155px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 197px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 158px;background-color:#D9E2F3;color:#0070C0" %)**Response**
673 673  |(% style="width:154px" %)AT+INTMOD=?|(% style="width:196px" %)Show current interrupt mode|(% style="width:157px" %)(((
674 674  0
675 675  OK
... ... @@ -692,6 +692,39 @@
692 692  * Example 1: Downlink Payload: 06000000  ~/~/  Turn off interrupt mode
693 693  * Example 2: Downlink Payload: 06000003  ~/~/  Set the interrupt mode to rising edge trigger
694 694  
1125 +
1126 +
1127 +
1128 +
1129 +
1130 +=== 3.3.11 Set Power Output Duration ===
1131 +
1132 +
1133 +Control the output duration 5V . Before each sampling, device will
1134 +
1135 +~1. first enable the power output to external sensor,
1136 +
1137 +2. keep it on as per duration, read sensor value and construct uplink payload
1138 +
1139 +3. final, close the power output.
1140 +
1141 +(% style="color:blue" %)**AT Command: AT+5VT**
1142 +
1143 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %)
1144 +|=(% style="width: 155px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 197px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 158px;background-color:#D9E2F3;color:#0070C0" %)**Response**
1145 +|(% style="width:154px" %)AT+5VT=?|(% style="width:196px" %)Show 5V open time.|(% style="width:157px" %)0 (default)
1146 +OK
1147 +|(% style="width:154px" %)AT+5VT=500|(% style="width:196px" %)Close after a delay of 1000 milliseconds.|(% style="width:157px" %)OK
1148 +
1149 +(% style="color:blue" %)**Downlink Command: 0x07**
1150 +
1151 +Format: Command Code (0x07) followed by 2 bytes.
1152 +
1153 +The first and second bytes are the time to turn on.
1154 +
1155 +* Example 1: Downlink Payload: 070000  **~-~-->**  AT+5VT=0
1156 +* Example 2: Downlink Payload: 0701F4  **~-~-->**  AT+5VT=500
1157 +
695 695  = 4. Battery & Power Consumption =
696 696  
697 697  
... ... @@ -716,7 +716,7 @@
716 716  Methods to Update Firmware:
717 717  
718 718  * (Recommanded way) OTA firmware update via wireless:   [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/Firmware%20OTA%20Update%20for%20Sensors/>>url:http://wiki.dragino.com/xwiki/bin/view/Main/Firmware%20OTA%20Update%20for%20Sensors/]]
719 -* Update through UART TTL interface.**[[Instruction>>url:http://wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H1.LoRaSTv4baseHardware]]**.
1182 +* Update through UART TTL interface. **[[Instruction>>url:http://wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H1.LoRaSTv4baseHardware]]**.
720 720  
721 721  = 6. FAQ =
722 722  
... ... @@ -725,7 +725,7 @@
725 725  = 7. Order Info =
726 726  
727 727  
728 -Part Number: (% style="color:blue" %)**S31-LB-XX  / S31B-LB-XX**(%%)
1191 +Part Number: (% style="color:blue" %)**S31-LB-XX  / S31B-LB-XX**
729 729  
730 730  (% style="color:red" %)**XX**(%%): The default frequency band
731 731  
... ... @@ -745,15 +745,14 @@
745 745  
746 746  * (% style="color:red" %)**CN470**(%%): LoRaWAN CN470 band
747 747  
748 -= =
749 -
750 750  = 8. ​Packing Info =
751 751  
752 -**Package Includes**:
753 753  
1214 +(% style="color:#037691" %)**Package Includes**:
1215 +
754 754  * S31x-LB LoRaWAN Temperature & Humidity Sensor
755 755  
756 -**Dimension and weight**:
1218 +(% style="color:#037691" %)**Dimension and weight**:
757 757  
758 758  * Device Size: cm
759 759  
... ... @@ -767,4 +767,5 @@
767 767  
768 768  
769 769  * Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule.
770 -* Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[support@dragino.com>>url:http://../../../../../../D:%5C%E5%B8%82%E5%9C%BA%E8%B5%84%E6%96%99%5C%E8%AF%B4%E6%98%8E%E4%B9%A6%5CLoRa%5CLT%E7%B3%BB%E5%88%97%5Csupport@dragino.com]]
1232 +
1233 +* Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[Support@dragino.cc>>mailto:Support@dragino.cc]].
image-20230523174230-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Xiaoling
Size
... ... @@ -1,0 +1,1 @@
1 +605.9 KB
Content
image-20230524105433-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Xiaoling
Size
... ... @@ -1,0 +1,1 @@
1 +121.4 KB
Content
image-20230524105747-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Xiaoling
Size
... ... @@ -1,0 +1,1 @@
1 +223.2 KB
Content
image-20230524110125-3.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Xiaoling
Size
... ... @@ -1,0 +1,1 @@
1 +194.1 KB
Content
image-20230524110211-4.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Xiaoling
Size
... ... @@ -1,0 +1,1 @@
1 +110.1 KB
Content
image-20230524114302-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Xiaoling
Size
... ... @@ -1,0 +1,1 @@
1 +12.0 KB
Content
image-20230524114654-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Xiaoling
Size
... ... @@ -1,0 +1,1 @@
1 +17.8 KB
Content
image-20230524114826-3.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Xiaoling
Size
... ... @@ -1,0 +1,1 @@
1 +82.3 KB
Content
image-20230524144422-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Xiaoling
Size
... ... @@ -1,0 +1,1 @@
1 +34.9 KB
Content
image-20230524144456-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Xiaoling
Size
... ... @@ -1,0 +1,1 @@
1 +33.9 KB
Content
image-20230527093155-1.jpeg
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Xiaoling
Size
... ... @@ -1,0 +1,1 @@
1 +9.3 KB
Content
image-20230527093214-2.jpeg
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Xiaoling
Size
... ... @@ -1,0 +1,1 @@
1 +14.7 KB
Content
image-20230530084138-1.jpeg
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Xiaoling
Size
... ... @@ -1,0 +1,1 @@
1 +1.1 MB
Content
image-20230530084608-2.jpeg
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Xiaoling
Size
... ... @@ -1,0 +1,1 @@
1 +1.1 MB
Content