Changes for page DS20L -- LoRaWAN Smart Distance Detector User Manual 01
Last modified by Mengting Qiu on 2023/12/14 11:15
From version 159.1
edited by Mengting Qiu
on 2023/12/09 18:03
on 2023/12/09 18:03
Change comment:
There is no comment for this version
To version 163.1
edited by Mengting Qiu
on 2023/12/11 11:54
on 2023/12/11 11:54
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 3 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -324,8 +324,12 @@ 324 324 325 325 * **Set the person or object count mode: AT+DOL=1,500,244,**(% style="color:red" %)1(%%)**,120** 326 326 327 -Continuous measurement, detect and count people or things passing by in distance limit mode. 327 +Continuous measurement, detect and count people or things passing by in distance limit mode. Uplink Payload totals 11 bytes. 328 328 329 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:600px" %) 330 +|(% style="background-color:#4f81bd; color:white; width:70px" %)**Size(bytes)**|(% style="background-color:#4f81bd; color:white; width:40px" %)**2**|(% style="background-color:#4f81bd; color:white; width:130px" %)**1**|(% style="background-color:#4f81bd; color:white; width:130px" %)**4**|(% style="background-color:#4f81bd; color:white; width:70px" %)**2**|(% style="background-color:#4f81bd; color:white; width:70px" %)**2** 331 +|(% style="width:91px" %)Value|(% style="width:41px" %)BAT|(% style="width:176px" %)MOD+Alarm+Do+Limit flag|(% style="width:176px" %)Distance Limit Alarm count|(% style="width:100px" %)Upper limit|(% style="width:119px" %)Lower limit 332 + 329 329 [[image:image-20231209173457-5.png||height="277" width="1098"]] 330 330 331 331 ... ... @@ -599,6 +599,29 @@ 599 599 600 600 * Example 3: Downlink Payload: 070300000064000190 **~-~-->** AT+MOD=3,0,100,0,400 601 601 606 + 607 +(% style="color:Red" %)**Note: The over-limit alarm the over-limit alarm.** (%%)For example: 608 + 609 +* **AT+MOD=1** 610 + 611 + **AT+DOL=1,500,244,**(% style="color:blue" %)0(%%)**,300** 612 + 613 +Send data according to the normal TDC time. If the mode limit is exceeded, the alarm flag is 1: 614 + 615 +[[image:image-20231211113204-2.png||height="292" width="1093"]] 616 + 617 +* **AT+MOD=2 ** 618 + 619 + **AT+DOL=1,500,244,**(% style="color:blue" %)0(%%)**,300** 620 + 621 +If the mode limit is exceeded, the data is immediately uplink and the alarm flag is 1: 622 + 623 +[[image:image-20231211114932-3.png||height="277" width="1248"]] 624 + 625 + 626 + 627 + 628 + 602 602 = 4. Battery & Power Consumption = 603 603 604 604
- image-20231211113113-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.ting - Size
-
... ... @@ -1,0 +1,1 @@ 1 +64.5 KB - Content
- image-20231211113204-2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.ting - Size
-
... ... @@ -1,0 +1,1 @@ 1 +59.7 KB - Content
- image-20231211114932-3.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.ting - Size
-
... ... @@ -1,0 +1,1 @@ 1 +57.3 KB - Content