Last modified by Mengting Qiu on 2023/12/14 11:15

From version 130.1
edited by Mengting Qiu
on 2023/12/06 15:46
Change comment: Uploaded new attachment "image-20231206154621-4.png", version {1}
To version 159.2
edited by Mengting Qiu
on 2023/12/11 11:27
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -47,8 +47,6 @@
47 47  * Firmware upgradable via program port or LoRa protocol
48 48  * Built-in 2400mAh battery or power by external power source
49 49  
50 -
51 -
52 52  == 1.3 Specification ==
53 53  
54 54  
... ... @@ -62,8 +62,6 @@
62 62  * ToF FoV: ±9°, Total 18°
63 63  * Light source: VCSEL
64 64  
65 -
66 -
67 67  == 1.4 Power Consumption ==
68 68  
69 69  
... ... @@ -77,8 +77,6 @@
77 77  * Idle: 21 mA @ 3.3v
78 78  * Max : 360 mA
79 79  
80 -
81 -
82 82  = 2. Configure DS20L to connect to LoRaWAN network =
83 83  
84 84  == 2.1 How it works ==
... ... @@ -97,7 +97,7 @@
97 97  
98 98  [[image:image-20231110102635-5.png||height="402" width="807"]](% style="display:none" %)
99 99  
100 -(% style="color:blue" %)**Step 1:**(%%) Create a device in TTN with the OTAA keys from DS20L.
94 +=== Step 1: Create a device in TTN with the OTAA keys from DS20L. ===
101 101  
102 102  Each DS20L is shipped with a sticker with the default device EUI as below:
103 103  
... ... @@ -104,41 +104,36 @@
104 104  [[image:image-20230426084152-1.png||alt="图片-20230426084152-1.png" height="233" width="502"]]
105 105  
106 106  
107 -You can enter this key in the LoRaWAN Server portal. Below is TTN screen shot:
101 +You can enter this key in the LoRaWAN Server portal. Below is TTN V3 screenshot:
108 108  
109 109  
110 110  (% style="color:blue" %)**Register the device**
111 111  
112 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LSN50v2-S31-S31B%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20User%20Manual/WebHome/1654935135620-998.png?rev=1.1||alt="1654935135620-998.png"]]
106 +[[image:image-20231207144600-2.png||height="703" width="756"]]
113 113  
114 114  
115 -(% style="color:blue" %)**Add APP EUI and DEV EUI**
109 +(% style="color:blue" %)**Add DevEUI and AppKey**
116 116  
117 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LSN50v2-S31-S31B%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20User%20Manual/WebHome/image-20220611161308-4.png?width=753&height=551&rev=1.1||alt="图片-20220611161308-4.png"]]
111 +[[image:image-20231207145121-5.png||height="540" width="756"]]
118 118  
119 119  
120 -(% style="color:blue" %)**Add APP EUI in the application**
121 121  
115 +=== Step 2: Activate on DS20L ===
122 122  
123 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LSN50v2-S31-S31B%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20User%20Manual/WebHome/image-20220611161308-5.png?width=742&height=601&rev=1.1||alt="图片-20220611161308-5.png"]]
124 -
125 -
126 -(% style="color:blue" %)**Add APP KEY**
127 -
128 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LSN50v2-S31-S31B%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20User%20Manual/WebHome/image-20220611161308-6.png?width=744&height=485&rev=1.1||alt="图片-20220611161308-6.png"]]
129 -
130 -
131 -(% style="color:blue" %)**Step 2:**(%%) Activate on DS20L
132 -
133 133  [[image:image-20231128133704-1.png||height="189" width="441"]]
134 134  
135 135  Press the button for 5 seconds to activate the DS20L.
136 136  
121 +The switch is switched to (% style="color:blue" %)**E** (%%)and the external power supply is used.
122 +
123 +The switch is switched to (% style="color:blue" %)**I** (%%)and the motherboard battery is used for power supply.
124 +
137 137  (% style="color:green" %)**Green led**(%%) will fast blink 5 times, device will enter (% style="color:blue" %)**OTA mode**(%%) for 3 seconds. And then start to JOIN LoRaWAN network. (% style="color:green" %)**Green led**(%%) will solidly turn on for 5 seconds after joined in network.
138 138  
139 139  After join success, it will start to upload messages to TTN and you can see the messages in the panel.
140 140  
141 141  
130 +
142 142  == 2.3 ​Uplink Payload ==
143 143  
144 144  === 2.3.1 Device Status, FPORT~=5 ===
... ... @@ -156,7 +156,7 @@
156 156  
157 157  Example parse in TTNv3
158 158  
159 -[[image:1701149922873-259.png]]
148 +[[image:image-20231206151412-3.png||height="179" width="1070"]]
160 160  
161 161  (% style="color:blue" %)**Sensor Model**(%%): For DS20L, this value is 0x21
162 162  
... ... @@ -212,7 +212,7 @@
212 212  === 2.3.2 Uplink Payload, FPORT~=2 ===
213 213  
214 214  
215 -==== (% style="color:red" %)**MOD~=1**(%%) ====
204 +==== (% style="color:red" %)**AT+MOD~=1**(%%) ====
216 216  
217 217  Regularly detect distance and report. When the distance exceeds the limit, the alarm flag is set to 1, and the report can be triggered by external interrupts.
218 218  
... ... @@ -222,7 +222,7 @@
222 222  |(% style="background-color:#4f81bd; color:white; width:60px" %)**Size(bytes)**|(% style="background-color:#4f81bd; color:white; width:30px" %)**2**|(% style="background-color:#4f81bd; color:white; width:130px" %)**1**|(% style="background-color:#4f81bd; color:white; width:70px" %)**2**|(% style="background-color:#4f81bd; color:white; width:100px" %)**1**|(% style="background-color:#4f81bd; color:white; width:120px" %)**4**
223 223  |(% style="width:91px" %)Value|(% style="width:41px" %)BAT|(% style="width:176px" %)MOD+ Alarm+Interrupt|(% style="width:74px" %)Distance|(% style="width:100px" %)Sensor State|(% style="width:119px" %)Interrupt Count
224 224  
225 -[[image:1701155076393-719.png]]
214 +[[image:image-20231209152917-1.png||height="300" width="1172"]]
226 226  
227 227  (% style="color:blue" %)**Battery Info:**
228 228  
... ... @@ -269,15 +269,24 @@
269 269  
270 270  
271 271  
272 -==== (% style="color:red" %)**MOD~=2**(%%)** ** ====
261 +==== (% style="color:red" %)**AT+MOD~=2**(%%)** ** ====
273 273  
274 -Uninterrupted measurement. When the distance exceeds the limit, the output IO is set high and reports are reported every five minutes. The time can be set and powered by an external power supply.Uplink Payload totals 11bytes.
275 275  
264 +The power consumption of uninterrupted measurement is high, and the device needs to use external power supply.(The switch is switched to E and the external power supply is used.)
265 +
266 +[[image:image-20231128133704-1.png||height="189" width="441"]]
267 +
268 +
269 +* **Set over-limit alarm mode: AT+DOL=3,500,244,**(% style="color:red" %)0(%%)**,120**
270 +
271 +(% class="wikigeneratedid" id="HUninterruptedmeasurement.Whenthedistanceexceedsthelimit2CtheoutputIOissethighandreportsarereportedeveryfiveminutes.Thetimecanbesetandpoweredbyanexternalpowersupply.UplinkPayloadtotals11bytes." %)
272 +Uninterrupted measurement. When the distance exceeds the limit, the output IO high, instant alarm. Uplink Payload totals 9 bytes.
273 +
276 276  (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %)
277 -|(% style="background-color:#4f81bd; color:white; width:70px" %)**Size(bytes)**|(% style="background-color:#4f81bd; color:white; width:40px" %)**2**|(% style="background-color:#4f81bd; color:white; width:130px" %)**1**|(% style="background-color:#4f81bd; color:white; width:130px" %)**4**|(% style="background-color:#4f81bd; color:white; width:70px" %)**2**|(% style="background-color:#4f81bd; color:white; width:70px" %)**2**
278 -|(% style="width:91px" %)Value|(% style="width:41px" %)BAT|(% style="width:176px" %)MOD+Alarm+Do+Limit flag|(% style="width:74px" %)Distance Limit Alarm count|(% style="width:100px" %)Upper limit|(% style="width:119px" %)Lower limit
275 +|(% style="background-color:#4f81bd; color:white; width:70px" %)**Size(bytes)**|(% style="background-color:#4f81bd; color:white; width:40px" %)**2**|(% style="background-color:#4f81bd; color:white; width:130px" %)**1**|(% style="background-color:#4f81bd; color:white; width:130px" %)**2**|(% style="background-color:#4f81bd; color:white; width:70px" %)**2**|(% style="background-color:#4f81bd; color:white; width:70px" %)**2**
276 +|(% style="width:91px" %)Value|(% style="width:41px" %)BAT|(% style="width:176px" %)MOD+Alarm+Do+Limit flag|(% style="width:74px" %)Distance |(% style="width:100px" %)Upper limit|(% style="width:119px" %)Lower limit
279 279  
280 -[[image:1701155150328-206.png]]
278 +[[image:image-20231209171127-3.png||height="374" width="1209"]]
281 281  
282 282  (% style="color:blue" %)**MOD & Alarm & Do & Limit flag:**
283 283  
... ... @@ -298,21 +298,22 @@
298 298  
299 299  (% style="color:red" %)**Limit flag:**
300 300  
301 -Mode for setting threshold: **0~~5**
299 +Mode for setting threshold: **0~~3**
302 302  
303 303  **0:** does not use upper and lower limits
304 304  
305 305  **1:** Use upper and lower limits
306 306  
307 -**2:** is less than the lower limit value
305 +**2:** Less than the upper limit
308 308  
309 -**3:** is greater than the lower limit value
307 +**3: **Greater than the lower limit
310 310  
311 -**4:** is less than the upper limit
312 312  
313 -**5:** is greater than the upper limit
310 +(% style="color:blue" %)**Distance:**
314 314  
312 + Actual sampling distance values.
315 315  
314 +
316 316  (% style="color:blue" %)**Upper limit:**
317 317  
318 318  The upper limit of the threshold cannot exceed 2000mm.
... ... @@ -323,12 +323,25 @@
323 323  The lower limit of the threshold cannot be less than 3mm.
324 324  
325 325  
325 +* **Set the person or object count mode: AT+DOL=1,500,244,**(% style="color:red" %)1(%%)**,120**
326 +
327 +Continuous measurement, detect and count people or things passing by in distance limit mode.
328 +
329 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:600px" %)
330 +|(% style="background-color:#4f81bd; color:white; width:70px" %)**Size(bytes)**|(% style="background-color:#4f81bd; color:white; width:40px" %)**2**|(% style="background-color:#4f81bd; color:white; width:130px" %)**1**|(% style="background-color:#4f81bd; color:white; width:130px" %)**4**|(% style="background-color:#4f81bd; color:white; width:70px" %)**2**|(% style="background-color:#4f81bd; color:white; width:70px" %)**2**
331 +|(% style="width:91px" %)Value|(% style="width:41px" %)BAT|(% style="width:176px" %)MOD+Alarm+Do+Limit flag|(% style="width:176px" %)Distance Limit Alarm count|(% style="width:100px" %)Upper limit|(% style="width:119px" %)Lower limit
332 +
333 +[[image:image-20231209173457-5.png||height="277" width="1098"]]
334 +
335 +
336 +
337 +
326 326  == 2.4 Decode payload in The Things Network ==
327 327  
328 328  
329 329  While using TTN network, you can add the payload format to decode the payload.
330 330  
331 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LLDS12-LoRaWAN%20LiDAR%20ToF%20Distance%20Sensor%20User%20Manual/WebHome/1654592762713-715.png?rev=1.1||alt="1654592762713-715.png"]]
343 +[[image:image-20231206143515-1.png||height="534" width="759"]]
332 332  
333 333  
334 334  (((
... ... @@ -357,17 +357,21 @@
357 357  )))
358 358  
359 359  
360 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDDS75%20-%20LoRaWAN%20Distance%20Detection%20Sensor%20User%20Manual/WebHome/1654592790040-760.png?rev=1.1||alt="1654592790040-760.png"]]
372 +[[image:image-20231207153532-6.png||height="562" width="861"]]
361 361  
362 362  
363 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDDS75%20-%20LoRaWAN%20Distance%20Detection%20Sensor%20User%20Manual/WebHome/1654592800389-571.png?rev=1.1||alt="1654592800389-571.png"]]
375 +[[image:image-20231207155940-8.png]]
364 364  
377 +For more detailed instructions, refer to the following instructions: [[Welcome - Datacake Docs>>url:https://docs.datacake.de/]]
365 365  
379 +[[image:image-20231207160733-11.png||height="429" width="759"]]
380 +
381 +
366 366  (% style="color:blue" %)**Step 3**(%%)**: Create an account or log in Datacake.**
367 367  
368 368  (% style="color:blue" %)**Step 4**(%%)**: Search the DS20L and add DevEUI.**
369 369  
370 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDDS75%20-%20LoRaWAN%20Distance%20Detection%20Sensor%20User%20Manual/WebHome/1654851029373-510.png?rev=1.1||alt="1654851029373-510.png"]]
386 +[[image:image-20231207160343-10.png||height="665" width="705"]]
371 371  
372 372  
373 373  After added, the sensor data arrive TTN V3, it will also arrive and show in Datacake.
... ... @@ -396,8 +396,6 @@
396 396  
397 397  * LoRaWAN Downlink.  Instruction for different platforms: See [[IoT LoRaWAN Server>>http://wiki.dragino.com/xwiki/bin/view/Main/]] section.
398 398  
399 -
400 -
401 401  == 3.2 General Commands ==
402 402  
403 403  
... ... @@ -501,8 +501,6 @@
501 501  
502 502  * Example 2: Downlink Payload: 06000003  ~/~/  Set the interrupt mode to rising edge trigger
503 503  
504 -
505 -
506 506  === 3.3.3 Set work mode ===
507 507  
508 508  
... ... @@ -520,12 +520,10 @@
520 520  
521 521  (% style="color:blue" %)**Downlink Command:**
522 522  
523 -* **Example: **0x0A0 ~/~/  Same as AT+MOD=0
535 +* **Example: **0x0A01 ~/~/  Same as AT+MOD=1
524 524  
525 -* **Example:** 0x0A01  ~/~/  Same as AT+MOD=1
537 +* **Example:** 0x0A02  ~/~/  Same as AT+MOD=2
526 526  
527 -
528 -
529 529  === 3.3.4 Set threshold and threshold mode ===
530 530  
531 531  
... ... @@ -543,8 +543,6 @@
543 543  )))
544 544  |(% style="width:172px" %)AT+ DOL =1,1800,100,0,400|(% style="width:279px" %)Set only the upper and lower thresholds|(% style="width:118px" %)OK
545 545  
546 -
547 -
548 548  (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %)
549 549  |(% rowspan="11" style="color:blue; width:120px" %)(((
550 550  
... ... @@ -558,53 +558,43 @@
558 558  
559 559  
560 560  
569 +**AT+DOL=5,1800,0,0,400**
570 +)))|(% rowspan="4" style="width:240px" %)(((
571 +
561 561  
562 562  
563 563  
564 564  
565 565  
566 -
567 -
568 -
569 -
570 -
571 -**AT+DOL=5,1800,0,0,400**
572 -)))|(% rowspan="6" style="width:240px" %)The first bit sets the limit mode|(% style="width:150px" %)0: Do not use upper and lower limits
577 +The first bit sets the limit mode
578 +)))|(% style="width:150px" %)0: Do not use upper and lower limits
573 573  |(% style="width:251px" %)1: Use upper and lower limits
574 -|(% style="width:251px" %)2: Less than the lower limit
580 +|(% style="width:251px" %)2:Less than the upper limit
575 575  |(% style="width:251px" %)3: Greater than the lower limit
576 -|(% style="width:251px" %)4: Less than the upper limit
577 -|(% style="width:251px" %)5: Greater than the upper limit
578 578  |(% style="width:226px" %)The second bit sets the upper limit value|(% style="width:251px" %)3~~2000MM
579 579  |(% style="width:226px" %)The third bit sets the lower limit value|(% style="width:251px" %)3~~2000MM
580 580  |(% rowspan="2" style="width:226px" %)The fourth bit sets the over-limit alarm or person or object count.|(% style="width:251px" %)0 Over-limit alarm, DO output is high
581 581  |(% style="width:251px" %)1 Person or object counting statistics
582 582  |(% style="width:226px" %)The fifth bit sets the sampling time|(% style="width:251px" %)(((
583 -0~~10000ms
587 +100~~10000ms
584 584  
585 585  
586 586  )))
587 587  
588 -
589 -
590 590  (% style="color:blue" %)**Downlink Command: 0x07**
591 591  
592 -Format: Command Code (0x07) followed by 9bytes.
594 +Format: Command Code (0x07) followed by 9 bytes.
593 593  
594 -* Example 0: Downlink Payload070000000000000190  **~-~-->**  AT+MOD=0,0,0,0,400
596 +If the downlink payload=**07 01 0708 0064 00 0190**, it means set the END Node's limit mode to 0x01,upper limit value to 0x0708=1800(mm), lower limit value to 0x0064=100(mm), to over-limit alarm(0x00) ,the sampling time to 0x0190=400(ms), while type code is 0x07.
595 595  
598 +* Example 0: Downlink Payload: 07 00 0000 0000 00 0190  **~-~-->**  AT+MOD=0,0,0,0,400
599 +
596 596  * Example 1: Downlink Payload: 070107080064000190  **~-~-->**  AT+MOD=1,1800,100,0,400
597 597  
598 -* Example 2: Downlink Payload: 070200000064000190  **~-~-->**  AT+MOD=2,0,100,0,400
602 +* Example 2: Downlink Payload: 070200000064000190  **~-~-->**  AT+MOD=2,1800100,0,400
599 599  
600 -* Example 3: Downlink Payload: 070300000064000190  **~-~-->**  AT+MOD=3,1800,100,0,400
604 +* Example 3: Downlink Payload: 070300000064000190  **~-~-->**  AT+MOD=3,0,100,0,400
601 601  
602 -* Example 4: Downlink Payload: 070407080000000190  **~-~-->**  AT+MOD=4,0,100,0,400
603 -
604 -* Example 5: Downlink Payload: 070507080000000190  **~-~-->**  AT+MOD=5,1800,100,0,400
605 -
606 -
607 -
608 608  = 4. Battery & Power Consumption =
609 609  
610 610  
... ... @@ -633,8 +633,6 @@
633 633  
634 634  * Update through UART TTL interface: **[[Instruction>>url:http://wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H1.LoRaSTv4baseHardware]]**.
635 635  
636 -
637 -
638 638  = 6. FAQ =
639 639  
640 640  == 6.1 What is the frequency plan for DS20L? ==
... ... @@ -722,8 +722,6 @@
722 722  
723 723  * (% style="color:red" %)**CN470**(%%): LoRaWAN CN470 band
724 724  
725 -
726 -
727 727  = 9. ​Packing Info =
728 728  
729 729  
... ... @@ -741,8 +741,6 @@
741 741  
742 742  * Weight / pcs : g
743 743  
744 -
745 -
746 746  = 10. Support =
747 747  
748 748  
image-20231206194804-5.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.ting
Size
... ... @@ -1,0 +1,1 @@
1 +53.7 KB
Content
image-20231206195704-6.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.ting
Size
... ... @@ -1,0 +1,1 @@
1 +64.1 KB
Content
image-20231207142208-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.ting
Size
... ... @@ -1,0 +1,1 @@
1 +27.2 KB
Content
image-20231207144600-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.ting
Size
... ... @@ -1,0 +1,1 @@
1 +55.4 KB
Content
image-20231207144837-3.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.ting
Size
... ... @@ -1,0 +1,1 @@
1 +31.1 KB
Content
image-20231207144856-4.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.ting
Size
... ... @@ -1,0 +1,1 @@
1 +31.1 KB
Content
image-20231207145121-5.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.ting
Size
... ... @@ -1,0 +1,1 @@
1 +33.3 KB
Content
image-20231207153532-6.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.ting
Size
... ... @@ -1,0 +1,1 @@
1 +164.7 KB
Content
image-20231207154046-7.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.ting
Size
... ... @@ -1,0 +1,1 @@
1 +23.0 KB
Content
image-20231207155940-8.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.ting
Size
... ... @@ -1,0 +1,1 @@
1 +41.7 KB
Content
image-20231207160053-9.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.ting
Size
... ... @@ -1,0 +1,1 @@
1 +95.5 KB
Content
image-20231207160343-10.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.ting
Size
... ... @@ -1,0 +1,1 @@
1 +80.5 KB
Content
image-20231207160733-11.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.ting
Size
... ... @@ -1,0 +1,1 @@
1 +136.0 KB
Content
image-20231209152917-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.ting
Size
... ... @@ -1,0 +1,1 @@
1 +65.9 KB
Content
image-20231209155616-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.ting
Size
... ... @@ -1,0 +1,1 @@
1 +57.1 KB
Content
image-20231209171127-3.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.ting
Size
... ... @@ -1,0 +1,1 @@
1 +80.8 KB
Content
image-20231209171549-4.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.ting
Size
... ... @@ -1,0 +1,1 @@
1 +45.7 KB
Content
image-20231209173457-5.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.ting
Size
... ... @@ -1,0 +1,1 @@
1 +66.3 KB
Content