Changes for page DS20L -- LoRaWAN Smart Distance Detector User Manual 01
Last modified by Mengting Qiu on 2023/12/14 11:15
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -493,7 +493,7 @@ 493 493 494 494 * Example 2: Downlink Payload: 06000003 ~/~/ Set the interrupt mode to rising edge trigger 495 495 496 -== =3.3.3 Set work mode ===496 +== 3.3.3 Set work mode == 497 497 498 498 499 499 Feature: Switch working mode ... ... @@ -532,10 +532,25 @@ 532 532 |(% style="width:172px" %)AT+ DOL =1,1800,100,0,400|(% style="width:279px" %)Set only the upper and lower thresholds|(% style="width:118px" %)OK 533 533 534 534 (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %) 535 -|(% rowspan="11" style="color:blue; width:120px" %)((( 535 +|(% rowspan="11" style="color:blue; width:120px" %)**AT+DOL=5,1800,0,0,400**|(% rowspan="6" style="width:240px" %)The first bit sets the limit mode|(% style="width:150px" %)0: Do not use upper and lower limits 536 +|(% style="width:251px" %)1: Use upper and lower limits 537 +|(% style="width:251px" %)2: Less than the lower limit 538 +|(% style="width:251px" %)3: Greater than the lower limit 539 +|(% style="width:251px" %)4: Less than the upper limit 540 +|(% style="width:251px" %)5: Greater than the upper limit 541 +|(% style="width:226px" %)The second bit sets the upper limit value|(% style="width:251px" %)3~~2000MM 542 +|(% style="width:226px" %)The third bit sets the lower limit value|(% style="width:251px" %)3~~2000MM 543 +|(% rowspan="2" style="width:226px" %)The fourth bit sets the over-limit alarm or person or object count.|(% style="width:251px" %)0 Over-limit alarm, DO output is high 544 +|(% style="width:251px" %)1 Person or object counting statistics 545 +|(% style="width:226px" %)The fifth bit sets the sampling time|(% style="width:251px" %)((( 546 +0~~10000ms 547 + 536 536 549 +))) 537 537 538 538 552 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %) 553 +|(% rowspan="11" style="color:blue; width:120px" %)** 539 539 540 540 541 541 ... ... @@ -542,10 +542,7 @@ 542 542 543 543 544 544 545 - 546 - 547 -**AT+DOL=5,1800,0,0,400** 548 -)))|(% rowspan="6" style="width:240px" %)The first bit sets the limit mode|(% style="width:150px" %)0: Do not use upper and lower limits 560 +AT+DOL=5,1800,0,0,400**|(% rowspan="6" style="width:240px" %)The first bit sets the limit mode|(% style="width:150px" %)0: Do not use upper and lower limits 549 549 |(% style="width:251px" %)1: Use upper and lower limits 550 550 |(% style="width:251px" %)2: Less than the lower limit 551 551 |(% style="width:251px" %)3: Greater than the lower limit ... ... @@ -561,11 +561,8 @@ 561 561 562 562 ))) 563 563 564 - 565 565 566 566 567 - 568 - 569 569 (% style="color:blue" %)**Downlink Command: 0x07** 570 570 571 571 Format: Command Code (0x07) followed by 9bytes.