Changes for page DS20L -- LoRaWAN Smart Distance Detector User Manual 01
Last modified by Mengting Qiu on 2023/12/14 11:15
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -47,6 +47,7 @@ 47 47 * Firmware upgradable via program port or LoRa protocol 48 48 * Built-in 2400mAh battery or power by external power source 49 49 50 + 50 50 == 1.3 Specification == 51 51 52 52 ... ... @@ -60,6 +60,7 @@ 60 60 * ToF FoV: ±9°, Total 18° 61 61 * Light source: VCSEL 62 62 64 + 63 63 == 1.4 Power Consumption == 64 64 65 65 ... ... @@ -73,6 +73,7 @@ 73 73 * Idle: 21 mA @ 3.3v 74 74 * Max : 360 mA 75 75 78 + 76 76 = 2. Configure DS20L to connect to LoRaWAN network = 77 77 78 78 == 2.1 How it works == ... ... @@ -493,7 +493,7 @@ 493 493 494 494 * Example 2: Downlink Payload: 06000003 ~/~/ Set the interrupt mode to rising edge trigger 495 495 496 -== =3.3.3 Set work mode ===499 +== 3.3.3 Set work mode == 497 497 498 498 499 499 Feature: Switch working mode ... ... @@ -532,20 +532,7 @@ 532 532 |(% style="width:172px" %)AT+ DOL =1,1800,100,0,400|(% style="width:279px" %)Set only the upper and lower thresholds|(% style="width:118px" %)OK 533 533 534 534 (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %) 535 -|(% rowspan="11" style="color:blue; width:120px" %)((( 536 - 537 - 538 - 539 - 540 - 541 - 542 - 543 - 544 - 545 - 546 - 547 -**AT+DOL=5,1800,0,0,400** 548 -)))|(% rowspan="6" style="width:240px" %)The first bit sets the limit mode|(% style="width:150px" %)0: Do not use upper and lower limits 538 +|(% rowspan="11" style="color:blue; width:120px" %)**AT+DOL=5,1800,0,0,400**|(% rowspan="6" style="width:240px" %)The first bit sets the limit mode|(% style="width:150px" %)0: Do not use upper and lower limits 549 549 |(% style="width:251px" %)1: Use upper and lower limits 550 550 |(% style="width:251px" %)2: Less than the lower limit 551 551 |(% style="width:251px" %)3: Greater than the lower limit ... ... @@ -561,11 +561,6 @@ 561 561 562 562 ))) 563 563 564 - 565 - 566 - 567 - 568 - 569 569 (% style="color:blue" %)**Downlink Command: 0x07** 570 570 571 571 Format: Command Code (0x07) followed by 9bytes. ... ... @@ -576,12 +576,13 @@ 576 576 577 577 * Example 2: Downlink Payload: 070200000064000190 **~-~-->** AT+MOD=2,0,100,0,400 578 578 579 -* Example 3: Downlink Payload: 070300000064000190 564 +* Example 3: Downlink Payload: 0703200000064000190 **~-~-->** AT+MOD=3,1800,100,0,400 580 580 581 581 * Example 4: Downlink Payload: 070407080000000190 **~-~-->** AT+MOD=4,0,100,0,400 582 582 583 583 * Example 5: Downlink Payload: 070507080000000190 **~-~-->** AT+MOD=5,1800,100,0,400 584 584 570 + 585 585 = 4. Battery & Power Consumption = 586 586 587 587