Changes for page DS20L -- LoRaWAN Smart Distance Detector User Manual 01
Last modified by Mengting Qiu on 2023/12/14 11:15
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -47,6 +47,7 @@ 47 47 * Firmware upgradable via program port or LoRa protocol 48 48 * Built-in 2400mAh battery or power by external power source 49 49 50 + 50 50 == 1.3 Specification == 51 51 52 52 ... ... @@ -60,6 +60,7 @@ 60 60 * ToF FoV: ±9°, Total 18° 61 61 * Light source: VCSEL 62 62 64 + 63 63 == 1.4 Power Consumption == 64 64 65 65 ... ... @@ -73,6 +73,7 @@ 73 73 * Idle: 21 mA @ 3.3v 74 74 * Max : 360 mA 75 75 78 + 76 76 = 2. Configure DS20L to connect to LoRaWAN network = 77 77 78 78 == 2.1 How it works == ... ... @@ -548,33 +548,6 @@ 548 548 549 549 ))) 550 550 551 - 552 -(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %) 553 -|(% rowspan="11" style="color:blue; width:120px" %)** 554 - 555 - 556 - 557 - 558 - 559 - 560 -AT+DOL=5,1800,0,0,400**|(% rowspan="6" style="width:240px" %)The first bit sets the limit mode|(% style="width:150px" %)0: Do not use upper and lower limits 561 -|(% style="width:251px" %)1: Use upper and lower limits 562 -|(% style="width:251px" %)2: Less than the lower limit 563 -|(% style="width:251px" %)3: Greater than the lower limit 564 -|(% style="width:251px" %)4: Less than the upper limit 565 -|(% style="width:251px" %)5: Greater than the upper limit 566 -|(% style="width:226px" %)The second bit sets the upper limit value|(% style="width:251px" %)3~~2000MM 567 -|(% style="width:226px" %)The third bit sets the lower limit value|(% style="width:251px" %)3~~2000MM 568 -|(% rowspan="2" style="width:226px" %)The fourth bit sets the over-limit alarm or person or object count.|(% style="width:251px" %)0 Over-limit alarm, DO output is high 569 -|(% style="width:251px" %)1 Person or object counting statistics 570 -|(% style="width:226px" %)The fifth bit sets the sampling time|(% style="width:251px" %)((( 571 -0~~10000ms 572 - 573 - 574 -))) 575 - 576 - 577 - 578 578 (% style="color:blue" %)**Downlink Command: 0x07** 579 579 580 580 Format: Command Code (0x07) followed by 9bytes. ... ... @@ -585,12 +585,13 @@ 585 585 586 586 * Example 2: Downlink Payload: 070200000064000190 **~-~-->** AT+MOD=2,0,100,0,400 587 587 588 -* Example 3: Downlink Payload: 070300000064000190 564 +* Example 3: Downlink Payload: 0703200000064000190 **~-~-->** AT+MOD=3,1800,100,0,400 589 589 590 590 * Example 4: Downlink Payload: 070407080000000190 **~-~-->** AT+MOD=4,0,100,0,400 591 591 592 592 * Example 5: Downlink Payload: 070507080000000190 **~-~-->** AT+MOD=5,1800,100,0,400 593 593 570 + 594 594 = 4. Battery & Power Consumption = 595 595 596 596