Changes for page DS20L -- LoRaWAN Smart Distance Detector User Manual 01
Last modified by Mengting Qiu on 2023/12/14 11:15
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -47,7 +47,6 @@ 47 47 * Firmware upgradable via program port or LoRa protocol 48 48 * Built-in 2400mAh battery or power by external power source 49 49 50 - 51 51 == 1.3 Specification == 52 52 53 53 ... ... @@ -61,7 +61,6 @@ 61 61 * ToF FoV: ±9°, Total 18° 62 62 * Light source: VCSEL 63 63 64 - 65 65 == 1.4 Power Consumption == 66 66 67 67 ... ... @@ -75,7 +75,6 @@ 75 75 * Idle: 21 mA @ 3.3v 76 76 * Max : 360 mA 77 77 78 - 79 79 = 2. Configure DS20L to connect to LoRaWAN network = 80 80 81 81 == 2.1 How it works == ... ... @@ -496,7 +496,7 @@ 496 496 497 497 * Example 2: Downlink Payload: 06000003 ~/~/ Set the interrupt mode to rising edge trigger 498 498 499 -== 3.3.3 Set work mode == 496 +=== 3.3.3 Set work mode === 500 500 501 501 502 502 Feature: Switch working mode ... ... @@ -534,8 +534,23 @@ 534 534 ))) 535 535 |(% style="width:172px" %)AT+ DOL =1,1800,100,0,400|(% style="width:279px" %)Set only the upper and lower thresholds|(% style="width:118px" %)OK 536 536 534 + 535 + 537 537 (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %) 538 -|(% rowspan="11" style="color:blue; width:120px" %)**AT+DOL=5,1800,0,0,400**|(% rowspan="6" style="width:240px" %)The first bit sets the limit mode|(% style="width:150px" %)0: Do not use upper and lower limits 537 +|(% rowspan="11" style="color:blue; width:120px" %)((( 538 + 539 + 540 + 541 + 542 + 543 + 544 + 545 + 546 + 547 + 548 + 549 +**AT+DOL=5,1800,0,0,400** 550 +)))|(% rowspan="6" style="width:240px" %)The first bit sets the limit mode|(% style="width:150px" %)0: Do not use upper and lower limits 539 539 |(% style="width:251px" %)1: Use upper and lower limits 540 540 |(% style="width:251px" %)2: Less than the lower limit 541 541 |(% style="width:251px" %)3: Greater than the lower limit ... ... @@ -551,6 +551,8 @@ 551 551 552 552 ))) 553 553 566 + 567 + 554 554 (% style="color:blue" %)**Downlink Command: 0x07** 555 555 556 556 Format: Command Code (0x07) followed by 9bytes. ... ... @@ -561,13 +561,12 @@ 561 561 562 562 * Example 2: Downlink Payload: 070200000064000190 **~-~-->** AT+MOD=2,0,100,0,400 563 563 564 -* Example 3: Downlink Payload: 0703 200000064000190 **~-~-->** AT+MOD=3,1800,100,0,400578 +* Example 3: Downlink Payload: 070300000064000190 **~-~-->** AT+MOD=3,1800,100,0,400 565 565 566 566 * Example 4: Downlink Payload: 070407080000000190 **~-~-->** AT+MOD=4,0,100,0,400 567 567 568 568 * Example 5: Downlink Payload: 070507080000000190 **~-~-->** AT+MOD=5,1800,100,0,400 569 569 570 - 571 571 = 4. Battery & Power Consumption = 572 572 573 573