Changes for page DS03A-LB/LS -- Outdoor LoRaWAN Door Sensor User Manual
Last modified by Mengting Qiu on 2025/01/10 09:53
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Xiaoling1 +XWiki.Ellie - Content
-
... ... @@ -320,7 +320,7 @@ 320 320 **Status & Alarm:** 321 321 322 322 (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:520px" %) 323 -|(% style=" width:60px;background-color:#D9E2F3;color:#0070C0" %)**Size(bit)**|(% style="width:80px;background-color:#D9E2F3;color:#0070C0" %)**bit7**|(% style="width:80px;background-color:#D9E2F3;color:#0070C0" %)**bit6**|(% style="width:60px;background-color:#D9E2F3;color:#0070C0" %)**[bit5:bit2]**|(% style="width:130px;background-color:#D9E2F3;color:#0070C0" %)**bit1**|(% style="width:110px;background-color:#D9E2F3;color:#0070C0" %)**bit0**323 +|(% style="background-color:#d9e2f3; color:#0070c0; width:60px" %)**Size(bit)**|(% style="background-color:#d9e2f3; color:#0070c0; width:80px" %)**bit7**|(% style="background-color:#d9e2f3; color:#0070c0; width:80px" %)**bit6**|(% style="background-color:#d9e2f3; color:#0070c0; width:60px" %)**[bit5:bit2]**|(% style="background-color:#d9e2f3; color:#0070c0; width:130px" %)**bit1**|(% style="background-color:#d9e2f3; color:#0070c0; width:110px" %)**bit0** 324 324 |(% style="width:76px" %)**Value**|(% style="width:79px" %)((( 325 325 No ACK Message 326 326 )))|(% style="width:84px" %)((( ... ... @@ -727,7 +727,7 @@ 727 727 |(% style="width:155px" %)((( 728 728 AT+TTRCHANNEL=1 729 729 )))|(% style="width:288px" %)((( 730 -set as single channel, only use P B14pin as interrupt pin.730 +set as single channel, only use PA8 pin as interrupt pin. 731 731 )))|(% style="width:44px" %)((( 732 732 OK 733 733 ))) ... ... @@ -734,7 +734,7 @@ 734 734 |(% style="width:155px" %)((( 735 735 AT+TTRCHANNEL=2 736 736 )))|(% style="width:288px" %)((( 737 -is set as dual channel, use P B14pin and PB15pin as interrupt pin.737 +is set as dual channel, use PA8 pin and PA4 pin as interrupt pin. 738 738 )))|(% style="width:44px" %)((( 739 739 OK 740 740 ))) ... ... @@ -789,32 +789,7 @@ 789 789 Example: 0C aa => AT+TTRALARM= aa 790 790 791 791 792 -=== 3.3.10 Select counting mode === 793 793 794 - 795 -(% style="color:blue" %)**AT+TTRMODx=a,b** 796 - 797 -When (% style="color:#037691" %)**a=0**(%%), the door is opened to count, and when (% style="color:#037691" %)**a=1**(%%),the closed door is counted. 798 - 799 -When (% style="color:#037691" %)**b=0**(%%), it is the last door open duration, and when (% style="color:#037691" %)**b=1**(%%),the last door close duration. 800 - 801 -(% style="color:blue" %)**AT Command:** 802 - 803 -(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %) 804 -|=(% style="width: 155px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 278px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 77px;background-color:#D9E2F3;color:#0070C0" %)**Response** 805 -|(% style="width:155px" %)((( 806 -AT+TTRMODx=1,0 807 -)))|(% style="width:278px" %)Door closed count and record the last door opened duration|(% style="width:85px" %)((( 808 -OK 809 -))) 810 -|(% style="width:155px" %)((( 811 -AT+TTRMODx=0,1 812 -)))|(% style="width:278px" %)((( 813 -Door opened count and record the last door Door Door open closed duration 814 -)))|(% style="width:85px" %)((( 815 -OK 816 -))) 817 - 818 818 = 4. Battery & Power Consumption = 819 819 820 820