Changes for page DS03A-LB/LS -- Outdoor LoRaWAN Door Sensor User Manual
Last modified by Mengting Qiu on 2025/01/10 09:53
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -253,7 +253,7 @@ 253 253 [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDS03A%20-%20Outdoor%20LoRaWAN%20OpenClose%20Door%20Sensor%20Manual/WebHome/image-20220609104802-1.png?rev=1.1||alt="image-20220609104802-1.png" height="393" width="1195"]] 254 254 255 255 256 -(% style="color:#037691" %)**Sensor Model**(%%): For DS03A-LB, this value is 0x 0B256 +(% style="color:#037691" %)**Sensor Model**(%%): For DS03A-LB, this value is 0x1B 257 257 258 258 (% style="color:#037691" %)**Firmware Version**(%%): 0x0100, Means: v1.0.0 version 259 259 ... ... @@ -323,13 +323,16 @@ 323 323 The last door open duration (unit: min) 324 324 )))|(% style="width:108px" %)[[Unix TimeStamp>>||anchor="H2.5.2UnixTimeStamp"]] 325 325 326 +**Status & Alarm:** 326 326 327 -(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:518.818px" %) 328 -|=(% colspan="4" style="background-color: rgb(217, 226, 243); color: rgb(0, 112, 192); width: 516px;" %)**Status & Alarm field** 329 -|(% style="width:76px" %)**Size(bit)**|(% style="width:70px" %)**6**|(% style="width:240px" %)**1**|(% style="width:130px" %)**1** 330 -|(% style="width:76px" %)**Value**|(% style="width:70px" %)Reserve|(% style="width:240px" %)[[Enable/disable Timeout Alarm>>||anchor="H3.3.3A0Enable2FDisableAlarm"]] 331 -0: No Alarm; 1: Alarm|(% style="width:130px" %)Status 332 -0: Close, 1: Open 328 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:520px" %) 329 +|(% style="background-color:#d9e2f3; color:#0070c0; width:60px" %)**Size(bit)**|(% style="background-color:#d9e2f3; color:#0070c0; width:80px" %)**bit7**|(% style="background-color:#d9e2f3; color:#0070c0; width:80px" %)**bit6**|(% style="background-color:#d9e2f3; color:#0070c0; width:60px" %)**[bit5:bit2]**|(% style="background-color:#d9e2f3; color:#0070c0; width:130px" %)**bit1**|(% style="background-color:#d9e2f3; color:#0070c0; width:110px" %)**bit0** 330 +|(% style="width:76px" %)**Value**|(% style="width:79px" %)((( 331 +No ACK Message 332 +)))|(% style="width:84px" %)((( 333 +Poll Message Flag 334 +)))|(% style="width:96px" %)Reserve|(% style="width:197px" %)[[Enable/disable Timeout Alarm>>||anchor="H3.3.3A0Enable2FDisableAlarm"]] 335 +0: No Alarm; 1: Alarm|(% style="width:104px" %)Status 0: Close, 1: Open 333 333 334 334 [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDS03A%20-%20Outdoor%20LoRaWAN%20OpenClose%20Door%20Sensor%20Manual/WebHome/image-20220609110547-6.png?width=1191&height=337&rev=1.1||alt="image-20220609110547-6.png" height="337" width="1191"]] 335 335