From version < 41.2 >
edited by Xiaoling
on 2024/01/15 09:40
To version < 46.1
edited by Mengting Qiu
on 2025/01/10 09:53
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.Xiaoling
1 +XWiki.ting
Content
... ... @@ -52,7 +52,7 @@
52 52  )))
53 53  
54 54  (((
55 -DS03A-LB/LS is powered by (% style="color:blue" %)**8500mAh Li-SOCI2 battery **(%%)or (% style="color:blue" %)**solar powered + li-on battery**(%%), it is designed for long term use up to 5 years.
55 +DS03A-LB/LS is powered by (% style="color:blue" %)**8500mAh Li-SOCI2 battery **(%%)or (% style="color:blue" %)**solar powered + Li-ion battery**(%%), it is designed for long term use up to 5 years.
56 56  )))
57 57  
58 58  (((
... ... @@ -72,6 +72,7 @@
72 72  * Door Open/Close detect
73 73  * Door open/close statistics
74 74  * Datalog Feature, Open Alarm Feature
75 +* Probe length: 40cm
75 75  * Support Bluetooth v5.1 and LoRaWAN remote configure
76 76  * Support wireless OTA update firmware
77 77  * Uplink on periodically
... ... @@ -79,7 +79,7 @@
79 79  * Wall Mountable
80 80  * Outdoor Use
81 81  * 8500mAh Li/SOCl2 Battery (DS03A-LB)
82 -* Solar panel + 3000mAh Li-on battery (DS03A-LS)
83 +* Solar panel + 3000mAh Li-ion battery (DS03A-LS)
83 83  
84 84  == 1.3 Specification ==
85 85  
... ... @@ -918,7 +918,7 @@
918 918  
919 919  (% style="color:blue" %)**Downlink Command to configure:**
920 920  
921 -If user send 0xA9 01 01 00 1E: equal to AT+TTRIG1=1,30 **or** 0xA9 01 00 00 00: Equal to AT+TTRIG1=0,0.
922 +If user send 0xA9 01 00 00 1E: equal to AT+TTRIG1=1,30 **or** 0xA9 01 00 00 00: Equal to AT+TTRIG1=0,0.
922 922  
923 923  
924 924  **2) AT+TTRIG2 : (PA4 of pin,need to use AT+TTRCHANNEL=2)**
... ... @@ -946,8 +946,10 @@
946 946  === 3.3.5  TTRIG1 & TTRIG2 timeout status alarm ===
947 947  
948 948  
949 -It needs to be used with AT+TTRIG1 or AT+TTRIG2. When TTRIG1 or TTRIG2 times out and causes an alarm, and the status does not change subsequently, an alarm packet will be sent at the alarm interval.
950 +It needs to be used with AT+TTRIG1 or AT+TTRIG2.
950 950  
952 +When TTRIG1 or TTRIG2 times out and causes an alarm, and the status does not change subsequently, an alarm packet will be sent at the alarm interval. (Max. 255 minutes)
953 +
951 951  (% style="color:blue" %)**AT Command:**
952 952  
953 953  (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %)
... ... @@ -1133,7 +1133,7 @@
1133 1133  * Update with new features.
1134 1134  * Fix bugs.
1135 1135  
1136 -Firmware and changelog can be downloaded from : **[[Firmware download link>>http://wiki.dragino.com/xwiki/bin/view/Main/Firmware%20OTA%20Update%20for%20Sensors/]]**
1139 +Firmware and changelog can be downloaded from : **[[Firmware download link>>https://www.dropbox.com/scl/fo/ztlw35a9xbkomu71u31im/AHx26Z9LCICx1Glt64ufq6o/LoRaWAN%20End%20Node/DS03A-LB?rlkey=ojjcsw927eaow01dgooldq3nu&subfolder_nav_tracking=1&dl=0]]**
1137 1137  
1138 1138  Methods to Update Firmware:
1139 1139  
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0