Changes for page DS03A-LB/LS -- Outdoor LoRaWAN Door Sensor User Manual
Last modified by Mengting Qiu on 2025/01/10 09:53
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -452,6 +452,7 @@ 452 452 453 453 [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/WebHome/image-20220703111700-2.png?width=1119&height=381&rev=1.1||alt="image-20220703111700-2.png" height="381" width="1119"]] 454 454 455 + 455 455 === 2.5.2 Unix TimeStamp === 456 456 457 457 ... ... @@ -480,6 +480,7 @@ 480 480 481 481 == 2.6 Show Data in DataCake IoT Server == 482 482 484 + 483 483 Datacake IoT platform provides a human-friendly interface to show the sensor data, once we have sensor data in TTN V3, we can use Datacake to connect to TTN V3 and see the data in Datacake. Below are the steps: 484 484 485 485 ... ... @@ -493,18 +493,24 @@ 493 493 494 494 [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDS03A%20-%20Outdoor%20LoRaWAN%20OpenClose%20Door%20Sensor%20Manual/WebHome/1654746405400-203.png?rev=1.1||alt="1654746405400-203.png"]] 495 495 498 + 496 496 [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDS03A%20-%20Outdoor%20LoRaWAN%20OpenClose%20Door%20Sensor%20Manual/WebHome/1654746763908-732.png?rev=1.1||alt="1654746763908-732.png"]] 497 497 498 498 [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDS03A%20-%20Outdoor%20LoRaWAN%20OpenClose%20Door%20Sensor%20Manual/WebHome/1654746716087-684.png?rev=1.1||alt="1654746716087-684.png"]] 499 499 503 + 500 500 [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDS03A%20-%20Outdoor%20LoRaWAN%20OpenClose%20Door%20Sensor%20Manual/WebHome/1654746693868-718.png?rev=1.1||alt="1654746693868-718.png"]] 501 501 506 + 502 502 [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDS03A%20-%20Outdoor%20LoRaWAN%20OpenClose%20Door%20Sensor%20Manual/WebHome/1654746674738-826.png?rev=1.1||alt="1654746674738-826.png"]] 503 503 509 + 504 504 [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDS03A%20-%20Outdoor%20LoRaWAN%20OpenClose%20Door%20Sensor%20Manual/WebHome/1654746646379-591.png?rev=1.1||alt="1654746646379-591.png"]] 505 505 512 + 506 506 [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDS03A%20-%20Outdoor%20LoRaWAN%20OpenClose%20Door%20Sensor%20Manual/WebHome/1654746549277-209.png?rev=1.1||alt="1654746549277-209.png"]] 507 507 515 + 508 508 [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDS03A%20-%20Outdoor%20LoRaWAN%20OpenClose%20Door%20Sensor%20Manual/WebHome/1654746593411-887.png?rev=1.1||alt="1654746593411-887.png"]] 509 509 510 510 ... ... @@ -595,11 +595,14 @@ 595 595 596 596 Feature: Enable/Disable Alarm for open/close event. Default value 0. 597 597 598 -**AT Command:** 606 +(% style="color:blue" %)**AT Command: ** 599 599 600 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDS03A%20-%20Outdoor%20LoRaWAN%20OpenClose%20Door%20Sensor%20Manual/WebHome/image-20220609140712-1.png?rev=1.1||alt="image-20220609140712-1.png"]] 608 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:520px" %) 609 +|(% style="background-color:#d9e2f3; color:#0070c0; width:154px" %)**Command Example**|(% style="background-color:#d9e2f3; color:#0070c0; width:278px" %)**Function**|(% style="background-color:#d9e2f3; color:#0070c0; width:88px" %)**Response** 610 +|(% style="width:154px" %)AT+DISALARM=1|(% style="width:278px" %)End node will only send packets in TDC time.|OK 611 +|(% style="width:154px" %)AT+DISALARM=0|(% style="width:278px" %)End node will send packets in TDC time or status change for door sensor|OK 601 601 602 -**Downlink Command:** 613 +(% style="color:blue" %)**Downlink Command: ** 603 603 604 604 0xA7 01 ~/~/ Same As AT+DISALARM=1 605 605 ... ... @@ -608,6 +608,7 @@ 608 608 609 609 === 3.3.4 Alarm Base on Timeout === 610 610 622 + 611 611 DS03A-LB can monitor the timeout for a status change, this feature can be used to monitor some events such as door opening too long etc. Related Parameters are: 612 612 613 613