Changes for page DS03A-LB/LS -- Outdoor LoRaWAN Door Sensor User Manual
Last modified by Mengting Qiu on 2025/01/10 09:53
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -308,11 +308,11 @@ 308 308 The last door open duration (unit: min) 309 309 )))|(% style="width:108px" %)[[Unix TimeStamp>>url:http://wiki.dragino.com/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDS03A%20-%20Outdoor%20LoRaWAN%20OpenClose%20Door%20Sensor%20Manual/#H2.4.1A0UnixTimeStamp]] 310 310 311 -(% border="1" cellspacing="4" style="background-color:#f2f2f2" %) 312 -|=(% colspan="4" style="background-color: #D9E2F3;color:#0070C0" %)**Status & Alarm field**313 -|**Size(bit)**|**6**|**1**|**1** 314 -|**Value**|Reserve|[[Enable/disable Timeout Alarm>>url:http://wiki.dragino.com/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDS03A%20-%20Outdoor%20LoRaWAN%20OpenClose%20Door%20Sensor%20Manual/#H3.8A0AlarmBaseonTimeout]] 315 -0: No Alarm; 1: Alarm|Status 311 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:518.818px" %) 312 +|=(% colspan="4" style="background-color: rgb(217, 226, 243); color: rgb(0, 112, 192); width: 516px;" %)**Status & Alarm field** 313 +|(% style="width:76px" %)**Size(bit)**|(% style="width:70px" %)**6**|(% style="width:240px" %)**1**|(% style="width:130px" %)**1** 314 +|(% style="width:76px" %)**Value**|(% style="width:70px" %)Reserve|(% style="width:240px" %)[[Enable/disable Timeout Alarm>>url:http://wiki.dragino.com/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDS03A%20-%20Outdoor%20LoRaWAN%20OpenClose%20Door%20Sensor%20Manual/#H3.8A0AlarmBaseonTimeout]] 315 +0: No Alarm; 1: Alarm|(% style="width:130px" %)Status 316 316 0: Close, 1: Open 317 317 318 318 [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDS03A%20-%20Outdoor%20LoRaWAN%20OpenClose%20Door%20Sensor%20Manual/WebHome/image-20220609110547-6.png?width=1191&height=337&rev=1.1||alt="image-20220609110547-6.png" height="337" width="1191"]] ... ... @@ -320,6 +320,7 @@ 320 320 321 321 === 2.3.3 Historical Door Open/Close Event, FPORT~=3 === 322 322 323 + 323 323 DS03A-LB stores sensor values and users can retrieve these history values via the [[downlink command>>url:http://wiki.dragino.com/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDS03A%20-%20Outdoor%20LoRaWAN%20OpenClose%20Door%20Sensor%20Manual/#H2.4A0DatalogFeature]]. 324 324 325 325 The historical payload includes one or multiplies entries and every entry has the same payload as Real-Time open/close status. ... ... @@ -385,13 +385,16 @@ 385 385 386 386 === 2.3.4 Sensor Configuration, FPORT~=4 === 387 387 389 + 388 388 DS03A-LB will only send this command after getting the downlink command (0x26 02) from the server. 389 389 390 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDS03A%20-%20Outdoor%20LoRaWAN%20OpenClose%20Door%20Sensor%20Manual/WebHome/image-20220609110123-5.png?rev=1.1||alt="image-20220609110123-5.png"]] 392 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %) 393 +|(% colspan="5" style="background-color:#d9e2f3; color:#0070c0; width:504px" %)**Sensor Configuration FPORT=4** 394 +|**Size(bytes)**|(% style="width:75px" %)**3**|(% style="width:77px" %)**1**|(% style="width:96px" %)**1**|(% style="width:158px" %)**2** 395 +|**Value**|(% style="width:75px" %)TDC (unit:sec)|(% style="width:77px" %)Disalarm|(% style="width:96px" %)Keep status|(% style="width:158px" %)Keep time (unit: min) 391 391 392 - 393 393 * ((( 394 -**TDC: (default: 0x001C20)** 398 +(% style="color:blue" %)**TDC: (default: 0x001C20)** 395 395 ))) 396 396 397 397 Uplink interval for the Open/Close Event, default value is 0x001C20 which is 7200 seconds = 2 hours. ... ... @@ -398,7 +398,7 @@ 398 398 399 399 400 400 * ((( 401 -**Disalarm: (default: 0)** 405 +(% style="color:blue" %)**Disalarm: (default: 0)** 402 402 ))) 403 403 404 404 **If Disalarm = 1**, DS03A-LB will only send uplink at every TDC periodically. This is normally use for pulse meter application, in this application, there are many open/close event, and platform only care about the total number of pulse. ... ... @@ -406,11 +406,11 @@ 406 406 **If Disalarm = 0**, DS03A-LB will send uplink at every TDC periodically and send data on each open/close event. This is useful for the application user need to monitor the open/close event in real-time. 407 407 408 408 409 -** ~Note: When Disalarm=0, a high frequently open/close event will cause lots of uplink and drain battery very fast. **413 +(% style="color:red" %)** Note: When Disalarm=0, a high frequently open/close event will cause lots of uplink and drain battery very fast. ** 410 410 411 411 412 412 * ((( 413 -**Keep Status & Keep Time** 417 +(% style="color:blue" %)**Keep Status & Keep Time** 414 414 ))) 415 415 416 416 Shows the configure value of [[Alarm Base on Timeout Feature>>url:http://wiki.dragino.com/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDS03A%20-%20Outdoor%20LoRaWAN%20OpenClose%20Door%20Sensor%20Manual/#H3.8A0AlarmBaseonTimeout]] ... ... @@ -433,7 +433,7 @@ 433 433 == 2.5 Datalog Feature == 434 434 435 435 436 -**Datalog Feature** is to ensure IoT Server can get all sampling data from Sensor even if the LoRaWAN network is down. For each sampling, DS03A-LB will store the reading for future retrieving purposes. 440 +(% style="color:blue" %)**Datalog Feature** (%%)is to ensure IoT Server can get all sampling data from Sensor even if the LoRaWAN network is down. For each sampling, DS03A-LB will store the reading for future retrieving purposes. 437 437 438 438 439 439 === 2.5.1 Ways to get datalog via LoRaWAN === ... ... @@ -448,6 +448,7 @@ 448 448 449 449 [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/WebHome/image-20220703111700-2.png?width=1119&height=381&rev=1.1||alt="image-20220703111700-2.png" height="381" width="1119"]] 450 450 455 + 451 451 === 2.5.2 Unix TimeStamp === 452 452 453 453 ... ... @@ -476,12 +476,13 @@ 476 476 477 477 == 2.6 Show Data in DataCake IoT Server == 478 478 484 + 479 479 Datacake IoT platform provides a human-friendly interface to show the sensor data, once we have sensor data in TTN V3, we can use Datacake to connect to TTN V3 and see the data in Datacake. Below are the steps: 480 480 481 481 482 -**Step 1: Link TTNv3 to Datacake.**[[https:~~/~~/docs.datacake.de/lorawan/lns/thethingsindustries#create-integration-on-tti>>url:https://docs.datacake.de/lorawan/lns/thethingsindustries#create-integration-on-tti]] 488 +(% style="color:blue" %)**Step 1:**(%%)** Link TTNv3 to Datacake.**[[https:~~/~~/docs.datacake.de/lorawan/lns/thethingsindustries#create-integration-on-tti>>url:https://docs.datacake.de/lorawan/lns/thethingsindustries#create-integration-on-tti]] 483 483 484 -**Step 2: Configure DS03A-LB in Datacake.** 490 +(% style="color:blue" %)**Step 2:**(%%)** Configure DS03A-LB in Datacake.** 485 485 486 486 [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDS03A%20-%20Outdoor%20LoRaWAN%20OpenClose%20Door%20Sensor%20Manual/WebHome/1654746350207-427.png?rev=1.1||alt="1654746350207-427.png"]] 487 487 ... ... @@ -489,18 +489,24 @@ 489 489 490 490 [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDS03A%20-%20Outdoor%20LoRaWAN%20OpenClose%20Door%20Sensor%20Manual/WebHome/1654746405400-203.png?rev=1.1||alt="1654746405400-203.png"]] 491 491 498 + 492 492 [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDS03A%20-%20Outdoor%20LoRaWAN%20OpenClose%20Door%20Sensor%20Manual/WebHome/1654746763908-732.png?rev=1.1||alt="1654746763908-732.png"]] 493 493 494 494 [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDS03A%20-%20Outdoor%20LoRaWAN%20OpenClose%20Door%20Sensor%20Manual/WebHome/1654746716087-684.png?rev=1.1||alt="1654746716087-684.png"]] 495 495 503 + 496 496 [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDS03A%20-%20Outdoor%20LoRaWAN%20OpenClose%20Door%20Sensor%20Manual/WebHome/1654746693868-718.png?rev=1.1||alt="1654746693868-718.png"]] 497 497 506 + 498 498 [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDS03A%20-%20Outdoor%20LoRaWAN%20OpenClose%20Door%20Sensor%20Manual/WebHome/1654746674738-826.png?rev=1.1||alt="1654746674738-826.png"]] 499 499 509 + 500 500 [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDS03A%20-%20Outdoor%20LoRaWAN%20OpenClose%20Door%20Sensor%20Manual/WebHome/1654746646379-591.png?rev=1.1||alt="1654746646379-591.png"]] 501 501 512 + 502 502 [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDS03A%20-%20Outdoor%20LoRaWAN%20OpenClose%20Door%20Sensor%20Manual/WebHome/1654746549277-209.png?rev=1.1||alt="1654746549277-209.png"]] 503 503 515 + 504 504 [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDS03A%20-%20Outdoor%20LoRaWAN%20OpenClose%20Door%20Sensor%20Manual/WebHome/1654746593411-887.png?rev=1.1||alt="1654746593411-887.png"]] 505 505 506 506 ... ... @@ -589,13 +589,17 @@ 589 589 590 590 === 3.3.3 Enable / Disable Alarm === 591 591 604 + 592 592 Feature: Enable/Disable Alarm for open/close event. Default value 0. 593 593 594 -**AT Command:** 607 +(% style="color:blue" %)**AT Command: ** 595 595 596 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDS03A%20-%20Outdoor%20LoRaWAN%20OpenClose%20Door%20Sensor%20Manual/WebHome/image-20220609140712-1.png?rev=1.1||alt="image-20220609140712-1.png"]] 609 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:520px" %) 610 +|(% style="background-color:#d9e2f3; color:#0070c0; width:154px" %)**Command Example**|(% style="background-color:#d9e2f3; color:#0070c0; width:278px" %)**Function**|(% style="background-color:#d9e2f3; color:#0070c0; width:88px" %)**Response** 611 +|(% style="width:154px" %)AT+DISALARM=1|(% style="width:278px" %)End node will only send packets in TDC time.|OK 612 +|(% style="width:154px" %)AT+DISALARM=0|(% style="width:278px" %)End node will send packets in TDC time or status change for door sensor|OK 597 597 598 -**Downlink Command:** 614 +(% style="color:blue" %)**Downlink Command: ** 599 599 600 600 0xA7 01 ~/~/ Same As AT+DISALARM=1 601 601 ... ... @@ -604,42 +604,43 @@ 604 604 605 605 === 3.3.4 Alarm Base on Timeout === 606 606 623 + 607 607 DS03A-LB can monitor the timeout for a status change, this feature can be used to monitor some events such as door opening too long etc. Related Parameters are: 608 608 609 609 610 610 * ((( 611 -**Keep Status: Status to be monitor** 628 +(% style="color:blue" %)**Keep Status: Status to be monitor** 612 612 ))) 613 613 614 -Keep Status = 1: Monitor Close to Open event 631 +(% style="color:#037691" %)**Keep Status = 1**(%%): Monitor Close to Open event 615 615 616 -Keep Status = 0: Monitor Open to Close event 633 +(% style="color:#037691" %)**Keep Status = 0**(%%): Monitor Open to Close event 617 617 618 618 619 619 * ((( 620 -**Keep Time: Timeout to send an Alarm** 637 +(% style="color:blue" %)**Keep Time: Timeout to send an Alarm** 621 621 ))) 622 622 623 623 Range 0 ~~ 65535(0xFFFF) seconds. 624 624 625 -If keep time = 0, Disable Alarm Base on Timeout feature. 642 +If (% style="color:#037691" %)**keep time = 0**(%%), Disable Alarm Base on Timeout feature. 626 626 627 -If keep time > 0, device will monitor the keep status event and send an alarm when status doesn't change after timeout. 644 +If (% style="color:#037691" %)**keep time > 0**(%%), device will monitor the keep status event and send an alarm when status doesn't change after timeout. 628 628 629 629 630 -**AT Command to configure:** 647 +(% style="color:blue" %)**AT Command to configure:** 631 631 632 632 * ((( 633 -**AT+TTRIG=1,30** 650 +(% style="color:#037691" %)**AT+TTRIG=1,30** (%%) **~-~->** When the **Keep Status** change from close to open, and device remains in open status for more than 30 seconds. LDS03A will send an uplink packet, the [[Alarm bit>>url:http://wiki.dragino.com/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDS03A%20-%20Outdoor%20LoRaWAN%20OpenClose%20Door%20Sensor%20Manual/#H2.3.3A0Real-TimeOpen2FCloseStatus2CUplinkFPORT3D2]] (the second bit of 1^^st^^ byte of payload) on this uplink packet is set to 1. 634 634 ))) 635 635 636 636 * ((( 637 -**AT+TTRIG=0,0** 654 +(% style="color:#037691" %)**AT+TTRIG=0,0** (%%) **~-~-> ** Default Value, disable timeout Alarm. 638 638 ))) 639 639 640 -**Downlink Command to configure:** 657 +(% style="color:blue" %)**Downlink Command to configure:** 641 641 642 -**Command: 0xA9 aa bb cc** 659 +(% style="color:#037691" %)**Command: 0xA9 aa bb cc** 643 643 644 644 **A9:** Command Type Code 645 645 ... ... @@ -657,8 +657,9 @@ 657 657 658 658 === 3.3.5 Count Mod === 659 659 660 -**AT Command:** 661 661 678 +(% style="color:blue" %)**AT Command:** 679 + 662 662 |=**Command Example**|=**Function**|=**Response** 663 663 |((( 664 664 AT+COUNTMOD=0 ... ... @@ -665,8 +665,6 @@ 665 665 )))|((( 666 666 the count value keeps accumulating mode 667 667 )))|((( 668 - 669 - 670 670 OK 671 671 ))) 672 672 |((( ... ... @@ -677,7 +677,7 @@ 677 677 OK 678 678 ))) 679 679 680 -**Downlink Command:** 696 +(% style="color:blue" %)**Downlink Command:** 681 681 682 682 Example: 0B aa => AT+COUNTMOD = second byte 683 683 ... ... @@ -684,8 +684,9 @@ 684 684 685 685 === 3.3.6 Interrupt Pin Channel Mod === 686 686 687 -**AT Command:** 688 688 704 +(% style="color:blue" %)**AT Command:** 705 + 689 689 |=**Command Example**|=**Function**|=**Response** 690 690 |((( 691 691 AT+TTRCHANNEL=1 ... ... @@ -692,8 +692,6 @@ 692 692 )))|((( 693 693 set as single channel, only use PB14 pin as interrupt pin. 694 694 )))|((( 695 - 696 - 697 697 OK 698 698 ))) 699 699 |((( ... ... @@ -704,7 +704,7 @@ 704 704 OK 705 705 ))) 706 706 707 -**Downlink Command:** 722 +(% style="color:blue" %)**Downlink Command:** 708 708 709 709 Example: 0D aa => AT+TTRCHANNEL = second byte 710 710 ... ... @@ -711,23 +711,26 @@ 711 711 712 712 === 3.3.7 Change the name of AT+TTRIG to AT+TTRIG1 === 713 713 714 -**Downlink Command:** 715 715 730 +(% style="color:blue" %)**Downlink Command:** 731 + 716 716 Example: A9 01 aa bb cc => AT+TTRIG1= third byte, 4th byte and 5th byte 717 717 718 718 719 719 === 3.3.8 Added AT+TTRIG2 for PB15 pin === 720 720 721 -**Downlink Command:** 722 722 738 +(% style="color:blue" %)**Downlink Command:** 739 + 723 723 Example: A9 02 aa bb cc => AT+TTRIG2= third byte, 4th byte and 5th byte 724 724 725 725 726 726 === 3.3.9 TTRIG1/2 timeout status alarm === 727 727 745 + 728 728 It needs to be used with AT+TTRIG1 or AT+TTRIG2. When TTRIG1 or TTRIG2 times out and causes an alarm, and the status does not change subsequently, an alarm packet will be sent at the alarm interval. 729 729 730 -**AT Command:** 748 +(% style="color:blue" %)**AT Command:** 731 731 732 732 |=**Command Example**|=**Function**|=**Response** 733 733 |((( ... ... @@ -735,8 +735,6 @@ 735 735 )))|((( 736 736 disable continuous alarm 737 737 )))|((( 738 - 739 - 740 740 OK 741 741 ))) 742 742 |((( ... ... @@ -747,7 +747,7 @@ 747 747 OK 748 748 ))) 749 749 750 -**Downlink Command:** 766 +(% style="color:blue" %)**Downlink Command:** 751 751 752 752 Example: 0C aa => AT+TTRALARM= aa 753 753 ... ... @@ -754,20 +754,19 @@ 754 754 755 755 === 3.3.9 Select counting mode === 756 756 757 -**AT+TTRMODx=a,b** 758 758 759 - When**a=0**,thedooris opened to count, and when**a=1**,the closed door is counted.774 +(% style="color:blue" %)**AT+TTRMODx=a,b** 760 760 761 -When ** b=0**,itis thelastdoor openuration, and when **b=1**,the lastdoorcloseduration.776 +When (% style="color:#037691" %)**a=0**(%%), the door is opened to count, and when (% style="color:#037691" %)**a=1**(%%),the closed door is counted. 762 762 763 -** ATCommand:**778 +When (% style="color:#037691" %)**b=0**(%%), it is the last door open duration, and when (% style="color:#037691" %)**b=1**(%%),the last door close duration. 764 764 780 +(% style="color:blue" %)**AT Command:** 781 + 765 765 |=**Command Example**|=**Function**|=**Response** 766 766 |((( 767 767 AT+TTRMODx=1,0 768 768 )))|Door closed count and record the last door opened duration|((( 769 - 770 - 771 771 OK 772 772 ))) 773 773 |(((