<
From version < 4.18 >
edited by Xiaoling
on 2023/05/16 10:17
To version < 4.16 >
edited by Xiaoling
on 2023/05/16 10:06
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -308,7 +308,6 @@
308 308  The last door open duration (unit: min)
309 309  )))|(% style="width:108px" %)[[Unix TimeStamp>>||anchor="H2.5.2UnixTimeStamp"]]
310 310  
311 -
312 312  (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:518.818px" %)
313 313  |=(% colspan="4" style="background-color: rgb(217, 226, 243); color: rgb(0, 112, 192); width: 516px;" %)**Status & Alarm field**
314 314  |(% style="width:76px" %)**Size(bit)**|(% style="width:70px" %)**6**|(% style="width:240px" %)**1**|(% style="width:130px" %)**1**
... ... @@ -444,7 +444,7 @@
444 444  === 2.5.1 Ways to get datalog via LoRaWAN ===
445 445  
446 446  
447 -Set PNACKMD=1, DS03A-LB will wait for ACK for every uplink, when there is no LoRaWAN network,DS03A-LB will mark these records with non-ack messages and store the sensor data, and it will send all messages (10s interval) after the network recovery.
446 +Set [[PNACKMD=1>>||anchor="H2.5.4DatalogUplinkpayloadA028FPORT3D329"]], DS03A-LB will wait for ACK for every uplink, when there is no LoRaWAN network,DS03A-LB will mark these records with non-ack messages and store the sensor data, and it will send all messages (10s interval) after the network recovery.
448 448  
449 449  * a) DS03A-LB will do an ACK check for data records sending to make sure every data arrive server.
450 450  * b) DS03A-LB will send data in **CONFIRMED Mode** when PNACKMD=1, but DS03A-LB won't re-transmit the packet if it doesn't get ACK, it will just mark it as a NONE-ACK message. In a future uplink if DS03A-LB gets a ACK, DS03A-LB will consider there is a network connection and resend all NONE-ACK Message.
... ... @@ -492,16 +492,13 @@
492 492  
493 493  [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDS03A%20-%20Outdoor%20LoRaWAN%20OpenClose%20Door%20Sensor%20Manual/WebHome/1654746350207-427.png?rev=1.1||alt="1654746350207-427.png"]]
494 494  
495 -
496 496  [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDS03A%20-%20Outdoor%20LoRaWAN%20OpenClose%20Door%20Sensor%20Manual/WebHome/1654747162439-840.png?rev=1.1||alt="1654747162439-840.png"]]
497 497  
498 -
499 499  [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDS03A%20-%20Outdoor%20LoRaWAN%20OpenClose%20Door%20Sensor%20Manual/WebHome/1654746405400-203.png?rev=1.1||alt="1654746405400-203.png"]]
500 500  
501 501  
502 502  [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDS03A%20-%20Outdoor%20LoRaWAN%20OpenClose%20Door%20Sensor%20Manual/WebHome/1654746763908-732.png?rev=1.1||alt="1654746763908-732.png"]]
503 503  
504 -
505 505  [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDS03A%20-%20Outdoor%20LoRaWAN%20OpenClose%20Door%20Sensor%20Manual/WebHome/1654746716087-684.png?rev=1.1||alt="1654746716087-684.png"]]
506 506  
507 507  
... ... @@ -709,7 +709,7 @@
709 709  (% style="color:blue" %)**AT Command:**
710 710  
711 711  (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:500px" %)
712 -|=(% style="width: 155px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 288px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 57px;background-color:#D9E2F3;color:#0070C0" %)**Response**
708 +|=(% style="width: 155px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 288px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 44px;background-color:#D9E2F3;color:#0070C0" %)**Response**
713 713  |(% style="width:155px" %)(((
714 714  AT+TTRCHANNEL=1
715 715  )))|(% style="width:288px" %)(((
... ... @@ -754,7 +754,7 @@
754 754  (% style="color:blue" %)**AT Command:**
755 755  
756 756  (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %)
757 -|=(% style="width: 155px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 279px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 76px;background-color:#D9E2F3;color:#0070C0" %)**Response**
753 +|=(% style="width: 155px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 279px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 84px;background-color:#D9E2F3;color:#0070C0" %)**Response**
758 758  |(% style="width:155px" %)(((
759 759  AT+TTRALARM=0
760 760  )))|(% style="width:279px" %)(((
... ... @@ -775,7 +775,7 @@
775 775  Example:  0C aa  => AT+TTRALARM= aa
776 776  
777 777  
778 -=== 3.3.10  Select counting mode ===
774 +=== 3.3.9  Select counting mode ===
779 779  
780 780  
781 781  (% style="color:blue" %)**AT+TTRMODx=a,b**
... ... @@ -787,7 +787,7 @@
787 787  (% style="color:blue" %)**AT Command:**
788 788  
789 789  (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %)
790 -|=(% style="width: 155px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 278px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 77px;background-color:#D9E2F3;color:#0070C0" %)**Response**
786 +|=(% style="width: 155px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 278px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 85px;background-color:#D9E2F3;color:#0070C0" %)**Response**
791 791  |(% style="width:155px" %)(((
792 792  AT+TTRMODx=1,0
793 793  )))|(% style="width:278px" %)Door closed count and record the last door opened duration|(% style="width:85px" %)(((
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0