Changes for page DS03A-LB/LS -- Outdoor LoRaWAN Door Sensor User Manual
Last modified by Mengting Qiu on 2025/01/10 09:53
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -2,7 +2,7 @@ 2 2 [[image:image-20230516085523-1.jpeg||height="491" width="491"]] 3 3 4 4 5 -**Table of Contents :**5 +**Table of Contents:** 6 6 7 7 {{toc/}} 8 8 ... ... @@ -79,6 +79,11 @@ 79 79 * Supply Voltage: built in 8500mAh Li-SOCI2 battery , 2.5v ~~ 3.6v 80 80 * Operating Temperature: -40 ~~ 85°C 81 81 82 +(% style="color:#037691" %)**Sensor Detect Distance:** 83 + 84 +* Wood Door: 10mm ~~ 30mm 85 +* Iron Door: 30 ~~ 45mm 86 + 82 82 (% style="color:#037691" %)**LoRa Spec:** 83 83 84 84 * Frequency Range, Band 1 (HF): 862 ~~ 1020 Mhz ... ... @@ -151,7 +151,6 @@ 151 151 152 152 [[image:image-20230630160843-7.png]] 153 153 154 - 155 155 == 1.9 Mechanical == 156 156 157 157 ... ... @@ -167,13 +167,6 @@ 167 167 [[image:Main.User Manual for LoRaWAN End Nodes.PS-LB -- LoRaWAN Pressure Sensor.WebHome@1675143909447-639.png]] 168 168 169 169 170 -== 1.10 Magnet Distance == 171 - 172 - 173 -* Wood Door: 10mm ~~ 30mm 174 -* Iron Door: 30 ~~ 45mm 175 - 176 - 177 177 = 2. Configure DS03A-LB to connect to LoRaWAN network = 178 178 179 179 == 2.1 How it works == ... ... @@ -239,13 +239,11 @@ 239 239 === 2.3.1 Device Status, FPORT~=5 === 240 240 241 241 242 - Includedeviceconfigurestatus.OnceDS03A-LBJoinedthenetwork,itwilluplink this messageto theserver.After that,DS03A-LB will uplinkDeviceStatusevery 12 hours.239 +Users can use the downlink command(**0x26 01**) to ask DS03A-LB to send device configure detail, include device configure status. DS03A-LB will uplink a payload via FPort=5 to server. 243 243 244 -Users can also use the downlink command**(0x26 01)** to ask DS03A-LB to resend this uplink. This uplink payload also includes the DeviceTimeReq to get time. 245 - 246 - 247 247 The Payload format is as below. 248 248 243 + 249 249 (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %) 250 250 |(% colspan="6" style="background-color:#d9e2f3; color:#0070c0" %)**Device Status (FPORT=5)** 251 251 |(% style="width:103px" %)**Size (bytes)**|(% style="width:72px" %)**1**|**2**|(% style="width:91px" %)**1**|(% style="width:86px" %)**1**|(% style="width:44px" %)**2** ... ... @@ -312,7 +312,7 @@ 312 312 === 2.3.2 Sensor Configuration, FPORT~=4 === 313 313 314 314 315 -DS03A-LB will only send this command after getting the downlink command **(0x26 02)**from the server.310 +DS03A-LB will only send this command after getting the downlink command (0x26 02) from the server. 316 316 317 317 (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:515px" %) 318 318 |(% colspan="8" style="background-color:#d9e2f3; color:#0070c0; width:515px" %)**Sensor Configuration FPORT=4** ... ... @@ -327,11 +327,6 @@ 327 327 Alarm interval(unit: min) 328 328 ))) 329 329 330 -Example parse in TTNv3 331 - 332 -[[image:image-20230630155527-3.png||height="146" width="902"]] 333 - 334 - 335 335 * ((( 336 336 (% style="color:blue" %)**TDC: (default: 0x001C20)** 337 337 ))) ... ... @@ -357,6 +357,7 @@ 357 357 358 358 Shows the configure value of [[Alarm Base on Timeout Feature>>||anchor="H3.3.3A0AlarmBaseonTimeout"]] 359 359 350 +[[image:image-20230630155527-3.png||height="146" width="902"]] 360 360 361 361 362 362 * ((( ... ... @@ -389,7 +389,7 @@ 389 389 390 390 (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:515px" %) 391 391 |(% style="background-color:#d9e2f3; color:#0070c0; width:50px" %)**Size(bit)**|(% style="background-color:#d9e2f3; color:#0070c0; width:60px" %)**[bit7:bit4]**|(% style="background-color:#d9e2f3; color:#0070c0; width:80px" %)**bit3**|(% style="background-color:#d9e2f3; color:#0070c0; width:100px" %)**bit2**|(% style="background-color:#d9e2f3; color:#0070c0; width:120px" %)**bit1**|(% style="background-color:#d9e2f3; color:#0070c0; width:105px" %)**bit0** 392 -|(% style="width:76px" %)Value|(% style="width:96px" %)Reserve|(% style="width:110px" %)((( 383 +|(% style="width:76px" %)**Value**|(% style="width:96px" %)Reserve|(% style="width:110px" %)((( 393 393 Count mod 394 394 )))|(% style="width:106px" %)TDC flag 0:No;1:Yes|(% style="width:148px" %)((( 395 395 Alarm 0: No Alarm; 1: Alarm ... ... @@ -404,9 +404,9 @@ 404 404 (% style="color:blue" %)**Count mod:Default=0** 405 405 ))) 406 406 407 -0 :Uplink total open door times since factory398 +MOD=0 ~-~-> Uplink total open door times since factory 408 408 409 -1 :Uplink total open door times since last FPORT=2 uplink.400 +MOD=1 ~-~-> Uplink total open door times since last FPORT=2 uplink. 410 410 411 411 412 412 * (% style="color:blue" %)**TDC flag** ... ... @@ -496,9 +496,9 @@ 496 496 (% style="color:blue" %)**Count mod:Default=0** 497 497 ))) 498 498 499 -0 :Uplink total open door times since factory490 +MOD=0 ~-~-> Uplink total open door times since factory 500 500 501 -1 :Uplink total open door times since last FPORT=2 uplink.492 +MOD=1 ~-~-> Uplink total open door times since last FPORT=2 uplink. 502 502 503 503 504 504 * (% style="color:blue" %)**TDC flag** ... ... @@ -801,39 +801,9 @@ 801 801 * Example 1: Downlink Payload: 0100001E ~/~/ Set Transmit Interval (TDC) = 30 seconds 802 802 * Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds 803 803 804 -=== 3.3.2 SetPowerOutputDuration===795 +=== 3.3.2 Enable / Disable Alarm === 805 805 806 806 807 -Control the output duration 5V . Before each sampling, device will 808 - 809 -~1. first enable the power output to external sensor, 810 - 811 -2. keep it on as per duration, read sensor value and construct uplink payload 812 - 813 -3. final, close the power output. 814 - 815 -(% style="color:blue" %)**AT Command: AT+5VT** 816 - 817 -(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %) 818 -|=(% style="width: 156px;background-color:#D9E2F3; color:#0070c0" %)**Command Example**|=(% style="width: 204px; background-color: rgb(217, 226, 243); color: rgb(0, 112, 192);" %)**Function**|=(% style="background-color: rgb(217, 226, 243); color: rgb(0, 112, 192); width: 149px;" %)**Response** 819 -|(% style="width:156px" %)AT+5VT=?|(% style="width:204px" %)Show 5V open time.|(% style="width:149px" %)0 (default) 820 -OK 821 -|(% style="width:156px" %)AT+5VT=500|(% style="width:204px" %)Close after a delay of 500 milliseconds.|(% style="width:149px" %)((( 822 -OK 823 - 824 -))) 825 - 826 -(% style="color:blue" %)**Downlink Command: 0x07**(%%) 827 -Format: Command Code (0x07) followed by 2 bytes. 828 - 829 -The first and second bytes are the time to turn on. 830 - 831 -* Example 1: Downlink Payload: 070000 **~-~-->** AT+5VT=0 832 -* Example 2: Downlink Payload: 0701F4 **~-~-->** AT+5VT=500 833 - 834 -=== 3.3.3 Enable / Disable Alarm === 835 - 836 - 837 837 Feature: Enable/Disable Alarm for open/close event. Default value 0. 838 838 839 839 (% style="color:blue" %)**AT Command: ** ... ... @@ -850,7 +850,7 @@ 850 850 0xA7 00 ~/~/ Same As AT+DISALARM=0 851 851 852 852 853 -=== 3.3. 4Alarm Base on Timeout ===814 +=== 3.3.3 Alarm Base on Timeout === 854 854 855 855 856 856 DS03A-LB can monitor the timeout for a status change, this feature can be used to monitor some events such as door opening too long etc. Related Parameters are: ... ... @@ -890,7 +890,7 @@ 890 890 **cc dd:** timeout. 891 891 892 892 893 -**1) AT+TTRIG1 854 +**1) AT+TTRIG1:(PA8 of pin)** 894 894 895 895 (% style="color:blue" %)**AT Command to configure:** 896 896 ... ... @@ -912,7 +912,7 @@ 912 912 If user send 0xA9 01 01 00 1E: equal to AT+TTRIG1=1,30 **or** 0xA9 01 00 00 00: Equal to AT+TTRIG1=0,0. 913 913 914 914 915 -**2) AT+TTRIG2 876 +**2) AT+TTRIG2:(PA4 of pin,need to use AT+TTRCHANNEL=2)** 916 916 917 917 (% style="color:blue" %)**AT Command to configure:** 918 918 ... ... @@ -934,7 +934,7 @@ 934 934 If user send 0xA9 02 00 00 1E: equal to AT+TTRIG2=0,30 **or** 0xA9 02 00 00 00: Equal to AT+TTRIG2=0,0. 935 935 936 936 937 -=== 3.3. 5TTRIG1 & TTRIG2 timeout status alarm ===898 +=== 3.3.4 TTRIG1 & TTRIG2 timeout status alarm === 938 938 939 939 940 940 It needs to be used with AT+TTRIG1 or AT+TTRIG2. When TTRIG1 or TTRIG2 times out and causes an alarm, and the status does not change subsequently, an alarm packet will be sent at the alarm interval. ... ... @@ -963,7 +963,7 @@ 963 963 Example: 0C aa => AT+TTRALARM= aa 964 964 965 965 966 -=== 3.3. 6Count Mod ===927 +=== 3.3.5 Count Mod === 967 967 968 968 969 969 Feature: Manually set the count mode. ... ... @@ -992,7 +992,7 @@ 992 992 Example: 0B aa => AT+COUNTMOD = second byte 993 993 994 994 995 -=== 3.3. 7Number of channel of door sensors ===956 +=== 3.3.6 Number of channel of door sensors === 996 996 997 997 998 998 Feature: Set the number of door sensor channels. ... ... @@ -1021,7 +1021,7 @@ 1021 1021 Example: 0D aa => AT+TTRCHANNEL = second byte 1022 1022 1023 1023 1024 -=== 3.3. 8Set Time Sync Mode ===985 +=== 3.3.7 Set Time Sync Mode === 1025 1025 1026 1026 1027 1027 Feature: Enable/Disable Sync system time via LoRaWAN MAC Command (DeviceTimeReq), LoRaWAN server must support v1.0.3 protocol to reply to this command. ... ... @@ -1059,13 +1059,13 @@ 1059 1059 0x28 00 ~/~/ Same As AT+SYNCMOD=0 1060 1060 1061 1061 1062 -=== 3.3. 9Clear the open door times and the duration of the last open door ===1023 +=== 3.3.8 Clear the open door times and the duration of the last open door === 1063 1063 1064 1064 1065 1065 (% style="color:blue" %)**AT Command:** 1066 1066 1067 -(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:5 10px" %)1068 -|=(% style="width: 1 63px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 290px; background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 57px;background-color:#D9E2F3;color:#0070C0" %)**Response**1028 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:500px" %) 1029 +|=(% style="width: 155px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 288px; background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 57px;background-color:#D9E2F3;color:#0070C0" %)**Response** 1069 1069 |(% style="width:155px" %)AT+CLRC|(% style="width:259px" %)clear the open door times and the duration of the last open door.|(% style="width:44px" %)((( 1070 1070 OK 1071 1071 ))) ... ... @@ -1075,7 +1075,7 @@ 1075 1075 The sensor will clear the open door times and the duration of the last open door. 1076 1076 1077 1077 1078 -=== 3.3. 10Set the count value of the number of open door ===1039 +=== 3.3.9 Set the count value of the number of open door === 1079 1079 1080 1080 1081 1081 (% style="color:blue" %)**AT Command:**