... ... @@ -2,7 +2,7 @@
2 2  [[image:image-20230516085523-1.jpeg||height="491" width="491"]]
3 3  
4 4  
5 -**Table of Contents:**
5 +**Table of Contents**
6 6  
7 7  {{toc/}}
8 8  
... ... @@ -79,6 +79,11 @@
79 79  * Supply Voltage: built in 8500mAh Li-SOCI2 battery , 2.5v ~~ 3.6v
80 80  * Operating Temperature: -40 ~~ 85°C
81 81  
82 +(% style="color:#037691" %)**Sensor Detect Distance:**
83 +
84 +* Wood Door: 10mm ~~ 30mm
85 +* Iron Door: 30 ~~ 45mm
86 +
82 82  (% style="color:#037691" %)**LoRa Spec:**
83 83  
84 84  * Frequency Range,  Band 1 (HF): 862 ~~ 1020 Mhz
... ... @@ -151,7 +151,6 @@
151 151  
152 152  [[image:image-20230630160843-7.png]]
153 153  
154 -
155 155  == 1.9 Mechanical ==
156 156  
157 157  
... ... @@ -167,13 +167,6 @@
167 167  [[image:Main.User Manual for LoRaWAN End Nodes.PS-LB -- LoRaWAN Pressure Sensor.WebHome@1675143909447-639.png]]
168 168  
169 169  
170 -== 1.10 Magnet Distance ==
171 -
172 -
173 -* Wood Door: 10mm ~~ 30mm
174 -* Iron Door: 30 ~~ 45mm
175 -
176 -
177 177  = 2. Configure DS03A-LB to connect to LoRaWAN network =
178 178  
179 179  == 2.1 How it works ==
... ... @@ -239,13 +239,11 @@
239 239  === 2.3.1 Device Status, FPORT~=5 ===
240 240  
241 241  
242 -Include device configure status. Once DS03A-LB Joined the network, it will uplink this message to the server. After that, DS03A-LB will uplink Device Status every 12 hours.
239 +Users can use the downlink command(**0x26 01**) to ask DS03A-LB to send device configure detail, include device configure status. DS03A-LB will uplink a payload via FPort=5 to server.
243 243  
244 -Users can also use the downlink command**(0x26 01)** to ask DS03A-LB to resend this uplink. This uplink payload also includes the DeviceTimeReq to get time.
245 -
246 -
247 247  The Payload format is as below.
248 248  
243 +
249 249  (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %)
250 250  |(% colspan="6" style="background-color:#d9e2f3; color:#0070c0" %)**Device Status (FPORT=5)**
251 251  |(% style="width:103px" %)**Size (bytes)**|(% style="width:72px" %)**1**|**2**|(% style="width:91px" %)**1**|(% style="width:86px" %)**1**|(% style="width:44px" %)**2**
... ... @@ -312,7 +312,7 @@
312 312  === 2.3.2  Sensor Configuration, FPORT~=4 ===
313 313  
314 314  
315 -DS03A-LB will only send this command after getting the downlink command **(0x26 02)** from the server.
310 +DS03A-LB will only send this command after getting the downlink command (0x26 02) from the server.
316 316  
317 317  (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:515px" %)
318 318  |(% colspan="8" style="background-color:#d9e2f3; color:#0070c0; width:515px" %)**Sensor Configuration FPORT=4**
... ... @@ -327,11 +327,6 @@
327 327  Alarm interval(unit: min)
328 328  )))
329 329  
330 -Example parse in TTNv3
331 -
332 -[[image:image-20230630155527-3.png||height="146" width="902"]]
333 -
334 -
335 335  * (((
336 336  (% style="color:blue" %)**TDC: (default: 0x001C20)**
337 337  )))
... ... @@ -357,6 +357,7 @@
357 357  
358 358  Shows the configure value of [[Alarm Base on Timeout Feature>>||anchor="H3.3.3A0AlarmBaseonTimeout"]]
359 359  
350 +[[image:image-20230630155527-3.png||height="146" width="902"]]
360 360  
361 361  
362 362  * (((
... ... @@ -404,9 +404,9 @@
404 404  (% style="color:blue" %)**Count mod:Default=0**
405 405  )))
406 406  
407 -0: Uplink total open door times since factory
398 +MOD=0 ~-~-> Uplink total open door times since factory
408 408  
409 -1: Uplink total open door times since last FPORT=2 uplink.
400 +MOD=1 ~-~-> Uplink total open door times since last FPORT=2 uplink.
410 410  
411 411  
412 412  * (% style="color:blue" %)**TDC flag**
... ... @@ -493,12 +493,12 @@
493 493  
494 494  
495 495  * (((
496 -(% style="color:blue" %)**Count mod:Default=0**
487 +(% style="color:blue" %)Count mod:Default=0
497 497  )))
498 498  
499 -0: Uplink total open door times since factory
490 +MOD=0 ~-~-> Uplink total open door times since factory
500 500  
501 -1: Uplink total open door times since last FPORT=2 uplink.
492 +MOD=1 ~-~-> Uplink total open door times since last FPORT=2 uplink.
502 502  
503 503  
504 504  * (% style="color:blue" %)**TDC flag**
... ... @@ -801,39 +801,9 @@
801 801  * Example 1: Downlink Payload: 0100001E  ~/~/  Set Transmit Interval (TDC) = 30 seconds
802 802  * Example 2: Downlink Payload: 0100003C  ~/~/  Set Transmit Interval (TDC) = 60 seconds
803 803  
804 -=== 3.3.2  Set Power Output Duration ===
795 +=== 3.3.2  Enable / Disable Alarm ===
805 805  
806 806  
807 -Control the output duration 5V . Before each sampling, device will
808 -
809 -~1. first enable the power output to external sensor,
810 -
811 -2. keep it on as per duration, read sensor value and construct uplink payload
812 -
813 -3. final, close the power output.
814 -
815 -(% style="color:blue" %)**AT Command: AT+5VT**
816 -
817 -(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %)
818 -|=(% style="width: 156px;background-color:#D9E2F3; color:#0070c0" %)**Command Example**|=(% style="width: 204px; background-color: rgb(217, 226, 243); color: rgb(0, 112, 192);" %)**Function**|=(% style="background-color: rgb(217, 226, 243); color: rgb(0, 112, 192); width: 149px;" %)**Response**
819 -|(% style="width:156px" %)AT+5VT=?|(% style="width:204px" %)Show 5V open time.|(% style="width:149px" %)0 (default)
820 -OK
821 -|(% style="width:156px" %)AT+5VT=500|(% style="width:204px" %)Close after a delay of 500 milliseconds.|(% style="width:149px" %)(((
822 -OK
823 -
824 -)))
825 -
826 -(% style="color:blue" %)**Downlink Command: 0x07**(%%)
827 -Format: Command Code (0x07) followed by 2 bytes.
828 -
829 -The first and second bytes are the time to turn on.
830 -
831 -* Example 1: Downlink Payload: 070000  **~-~-->**  AT+5VT=0
832 -* Example 2: Downlink Payload: 0701F4  **~-~-->**  AT+5VT=500
833 -
834 -=== 3.3.3  Enable / Disable Alarm ===
835 -
836 -
837 837  Feature: Enable/Disable Alarm for open/close event. Default value 0.
838 838  
839 839  (% style="color:blue" %)**AT Command: **
... ... @@ -850,7 +850,7 @@
850 850  0xA7 00  ~/~/ Same As AT+DISALARM=0
851 851  
852 852  
853 -=== 3.3.4  Alarm Base on Timeout ===
814 +=== 3.3.3  Alarm Base on Timeout ===
854 854  
855 855  
856 856  DS03A-LB can monitor the timeout for a status change, this feature can be used to monitor some events such as door opening too long etc. Related Parameters are:
... ... @@ -890,7 +890,7 @@
890 890  **cc dd:** timeout.
891 891  
892 892  
893 -**1) AT+TTRIG1 : (PA8 of pin)**
854 +**1) AT+TTRIG1:(PA8 of pin)**
894 894  
895 895  (% style="color:blue" %)**AT Command to configure:**
896 896  
... ... @@ -912,7 +912,7 @@
912 912  If user send 0xA9 01 01 00 1E: equal to AT+TTRIG1=1,30 **or** 0xA9 01 00 00 00: Equal to AT+TTRIG1=0,0.
913 913  
914 914  
915 -**2) AT+TTRIG2 : (PA4 of pin,need to use AT+TTRCHANNEL=2)**
876 +**2) AT+TTRIG2:(PA4 of pin,need to use AT+TTRCHANNEL=2)**
916 916  
917 917  (% style="color:blue" %)**AT Command to configure:**
918 918  
... ... @@ -934,7 +934,7 @@
934 934  If user send 0xA9 02 00 00 1E: equal to AT+TTRIG2=0,30  **or**  0xA9 02 00 00 00: Equal to AT+TTRIG2=0,0.
935 935  
936 936  
937 -=== 3.3.5  TTRIG1 & TTRIG2 timeout status alarm ===
898 +=== 3.3.4  TTRIG1 & TTRIG2 timeout status alarm ===
938 938  
939 939  
940 940  It needs to be used with AT+TTRIG1 or AT+TTRIG2. When TTRIG1 or TTRIG2 times out and causes an alarm, and the status does not change subsequently, an alarm packet will be sent at the alarm interval.
... ... @@ -963,7 +963,7 @@
963 963  Example:  0C aa  => AT+TTRALARM= aa
964 964  
965 965  
966 -=== 3.3.6  Count Mod ===
927 +=== 3.3.5  Count Mod ===
967 967  
968 968  
969 969  Feature: Manually set the count mode.
... ... @@ -992,7 +992,7 @@
992 992  Example:  0B aa  => AT+COUNTMOD = second byte
993 993  
994 994  
995 -=== 3.3.7  Number of channel of door sensors ===
956 +=== 3.3.6  Number of channel of door sensors ===
996 996  
997 997  
998 998  Feature: Set the number of door sensor channels.
... ... @@ -1021,7 +1021,7 @@
1021 1021  Example:  0D aa => AT+TTRCHANNEL = second byte
1022 1022  
1023 1023  
1024 -=== 3.3.8  Set Time Sync Mode ===
985 +=== 3.3.7  Set Time Sync Mode ===
1025 1025  
1026 1026  
1027 1027  Feature: Enable/Disable Sync system time via LoRaWAN MAC Command (DeviceTimeReq), LoRaWAN server must support v1.0.3 protocol to reply to this command.
... ... @@ -1059,13 +1059,13 @@
1059 1059  0x28 00  ~/~/ Same As AT+SYNCMOD=0
1060 1060  
1061 1061  
1062 -=== 3.3.9  Clear the open door times and the duration of the last open door ===
1023 +=== 3.3.8  Clear the open door times and the duration of the last open door ===
1063 1063  
1064 1064  
1065 1065  (% style="color:blue" %)**AT Command:**
1066 1066  
1067 -(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %)
1068 -|=(% style="width: 163px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 290px; background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 57px;background-color:#D9E2F3;color:#0070C0" %)**Response**
1028 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:500px" %)
1029 +|=(% style="width: 155px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 288px; background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 57px;background-color:#D9E2F3;color:#0070C0" %)**Response**
1069 1069  |(% style="width:155px" %)AT+CLRC|(% style="width:259px" %)clear the open door times and the duration of the last open door.|(% style="width:44px" %)(((
1070 1070  OK
1071 1071  )))
... ... @@ -1075,7 +1075,7 @@
1075 1075  The sensor will clear the open door times and the duration of the last open door.
1076 1076  
1077 1077  
1078 -=== 3.3.10  Set the count value of the number of open door ===
1039 +=== 3.3.9  Set the count value of the number of open door ===
1079 1079  
1080 1080  
1081 1081  (% style="color:blue" %)**AT Command:**
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved