... ... @@ -71,8 +71,6 @@
71 71  * Wall Mountable
72 72  * Outdoor Use
73 73  
74 -
75 -
76 76  == 1.3 Specification ==
77 77  
78 78  
... ... @@ -106,8 +106,6 @@
106 106  * Sleep Mode: 5uA @ 3.3v
107 107  * LoRa Transmit Mode: 125mA @ 20dBm, 82mA @ 14dBm
108 108  
109 -
110 -
111 111  == 1.4 Applications ==
112 112  
113 113  
... ... @@ -141,8 +141,6 @@
141 141  )))
142 142  |(% style="width:167px" %)Fast press ACT 5 times.|(% style="width:117px" %)Deactivate Device|(% style="width:225px" %)(% style="color:red" %)**Red led**(%%) will solid on for 5 seconds. Means Device is in Deep Sleep Mode.
143 143  
144 -
145 -
146 146  == 1.7 BLE connection ==
147 147  
148 148  
... ... @@ -162,7 +162,6 @@
162 162  
163 163  [[image:image-20230630160843-7.png]]
164 164  
165 -
166 166  == 1.9 Mechanical ==
167 167  
168 168  
... ... @@ -243,13 +243,11 @@
243 243  === 2.3.1 Device Status, FPORT~=5 ===
244 244  
245 245  
246 -Include device configure status. Once DS03A-LB Joined the network, it will uplink this message to the server. After that, DS03A-LB will uplink Device Status every 12 hours.
239 +Users can use the downlink command(**0x26 01**) to ask DS03A-LB to send device configure detail, include device configure status. DS03A-LB will uplink a payload via FPort=5 to server.
247 247  
248 -Users can also use the downlink command**(0x26 01)** to ask DS03A-LB to resend this uplink. This uplink payload also includes the DeviceTimeReq to get time.
249 -
250 -
251 251  The Payload format is as below.
252 252  
243 +
253 253  (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %)
254 254  |(% colspan="6" style="background-color:#d9e2f3; color:#0070c0" %)**Device Status (FPORT=5)**
255 255  |(% style="width:103px" %)**Size (bytes)**|(% style="width:72px" %)**1**|**2**|(% style="width:91px" %)**1**|(% style="width:86px" %)**1**|(% style="width:44px" %)**2**
... ... @@ -316,7 +316,7 @@
316 316  === 2.3.2  Sensor Configuration, FPORT~=4 ===
317 317  
318 318  
319 -DS03A-LB will only send this command after getting the downlink command **(0x26 02)** from the server.
310 +DS03A-LB will only send this command after getting the downlink command (0x26 02) from the server.
320 320  
321 321  (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:515px" %)
322 322  |(% colspan="8" style="background-color:#d9e2f3; color:#0070c0; width:515px" %)**Sensor Configuration FPORT=4**
... ... @@ -331,11 +331,6 @@
331 331  Alarm interval(unit: min)
332 332  )))
333 333  
334 -Example parse in TTNv3
335 -
336 -[[image:image-20230630155527-3.png||height="146" width="902"]]
337 -
338 -
339 339  * (((
340 340  (% style="color:blue" %)**TDC: (default: 0x001C20)**
341 341  )))
... ... @@ -361,6 +361,7 @@
361 361  
362 362  Shows the configure value of [[Alarm Base on Timeout Feature>>||anchor="H3.3.3A0AlarmBaseonTimeout"]]
363 363  
350 +[[image:image-20230630155527-3.png||height="146" width="902"]]
364 364  
365 365  
366 366  * (((
... ... @@ -408,9 +408,9 @@
408 408  (% style="color:blue" %)**Count mod:Default=0**
409 409  )))
410 410  
411 -0: Uplink total open door times since factory
398 +MOD=0 ~-~-> Uplink total open door times since factory
412 412  
413 -1: Uplink total open door times since last FPORT=2 uplink.
400 +MOD=1 ~-~-> Uplink total open door times since last FPORT=2 uplink.
414 414  
415 415  
416 416  * (% style="color:blue" %)**TDC flag**
... ... @@ -497,12 +497,12 @@
497 497  
498 498  
499 499  * (((
500 -(% style="color:blue" %)**Count mod:Default=0**
487 +(% style="color:blue" %)Count mod:Default=0
501 501  )))
502 502  
503 -0: Uplink total open door times since factory
490 +MOD=0 ~-~-> Uplink total open door times since factory
504 504  
505 -1: Uplink total open door times since last FPORT=2 uplink.
492 +MOD=1 ~-~-> Uplink total open door times since last FPORT=2 uplink.
506 506  
507 507  
508 508  * (% style="color:blue" %)**TDC flag**
... ... @@ -758,8 +758,6 @@
758 758  * AT Command via UART Connection : See [[Connection>>http://wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H2.3UARTConnectionforSN50v3basemotherboard]].
759 759  * LoRaWAN Downlink.  Instruction for different platforms: See [[IoT LoRaWAN Server>>http://wiki.dragino.com/xwiki/bin/view/Main/]] section.
760 760  
761 -
762 -
763 763  == 3.2 General Commands ==
764 764  
765 765  
... ... @@ -807,43 +807,9 @@
807 807  * Example 1: Downlink Payload: 0100001E  ~/~/  Set Transmit Interval (TDC) = 30 seconds
808 808  * Example 2: Downlink Payload: 0100003C  ~/~/  Set Transmit Interval (TDC) = 60 seconds
809 809  
795 +=== 3.3.2  Enable / Disable Alarm ===
810 810  
811 811  
812 -=== 3.3.2  Set Power Output Duration ===
813 -
814 -
815 -Control the output duration 5V . Before each sampling, device will
816 -
817 -~1. first enable the power output to external sensor,
818 -
819 -2. keep it on as per duration, read sensor value and construct uplink payload
820 -
821 -3. final, close the power output.
822 -
823 -(% style="color:blue" %)**AT Command: AT+5VT**
824 -
825 -(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %)
826 -|=(% style="width: 156px;background-color:#D9E2F3; color:#0070c0" %)**Command Example**|=(% style="width: 204px; background-color: rgb(217, 226, 243); color: rgb(0, 112, 192);" %)**Function**|=(% style="background-color: rgb(217, 226, 243); color: rgb(0, 112, 192); width: 149px;" %)**Response**
827 -|(% style="width:156px" %)AT+5VT=?|(% style="width:204px" %)Show 5V open time.|(% style="width:149px" %)0 (default)
828 -OK
829 -|(% style="width:156px" %)AT+5VT=500|(% style="width:204px" %)Close after a delay of 500 milliseconds.|(% style="width:149px" %)(((
830 -OK
831 -
832 -)))
833 -
834 -(% style="color:blue" %)**Downlink Command: 0x07**(%%)
835 -Format: Command Code (0x07) followed by 2 bytes.
836 -
837 -The first and second bytes are the time to turn on.
838 -
839 -* Example 1: Downlink Payload: 070000  **~-~-->**  AT+5VT=0
840 -* Example 2: Downlink Payload: 0701F4  **~-~-->**  AT+5VT=500
841 -
842 -
843 -
844 -=== 3.3.3  Enable / Disable Alarm ===
845 -
846 -
847 847  Feature: Enable/Disable Alarm for open/close event. Default value 0.
848 848  
849 849  (% style="color:blue" %)**AT Command: **
... ... @@ -860,7 +860,7 @@
860 860  0xA7 00  ~/~/ Same As AT+DISALARM=0
861 861  
862 862  
863 -=== 3.3.4  Alarm Base on Timeout ===
814 +=== 3.3.3  Alarm Base on Timeout ===
864 864  
865 865  
866 866  DS03A-LB can monitor the timeout for a status change, this feature can be used to monitor some events such as door opening too long etc. Related Parameters are:
... ... @@ -900,7 +900,7 @@
900 900  **cc dd:** timeout.
901 901  
902 902  
903 -**1) AT+TTRIG1 : (PA8 of pin)**
854 +**1) AT+TTRIG1:(PA8 of pin)**
904 904  
905 905  (% style="color:blue" %)**AT Command to configure:**
906 906  
... ... @@ -922,7 +922,7 @@
922 922  If user send 0xA9 01 01 00 1E: equal to AT+TTRIG1=1,30 **or** 0xA9 01 00 00 00: Equal to AT+TTRIG1=0,0.
923 923  
924 924  
925 -**2) AT+TTRIG2 : (PA4 of pin,need to use AT+TTRCHANNEL=2)**
876 +**2) AT+TTRIG2:(PA4 of pin,need to use AT+TTRCHANNEL=2)**
926 926  
927 927  (% style="color:blue" %)**AT Command to configure:**
928 928  
... ... @@ -944,7 +944,7 @@
944 944  If user send 0xA9 02 00 00 1E: equal to AT+TTRIG2=0,30  **or**  0xA9 02 00 00 00: Equal to AT+TTRIG2=0,0.
945 945  
946 946  
947 -=== 3.3.5  TTRIG1 & TTRIG2 timeout status alarm ===
898 +=== 3.3.4  TTRIG1 & TTRIG2 timeout status alarm ===
948 948  
949 949  
950 950  It needs to be used with AT+TTRIG1 or AT+TTRIG2. When TTRIG1 or TTRIG2 times out and causes an alarm, and the status does not change subsequently, an alarm packet will be sent at the alarm interval.
... ... @@ -973,7 +973,7 @@
973 973  Example:  0C aa  => AT+TTRALARM= aa
974 974  
975 975  
976 -=== 3.3.6  Count Mod ===
927 +=== 3.3.5  Count Mod ===
977 977  
978 978  
979 979  Feature: Manually set the count mode.
... ... @@ -1002,7 +1002,7 @@
1002 1002  Example:  0B aa  => AT+COUNTMOD = second byte
1003 1003  
1004 1004  
1005 -=== 3.3.7  Number of channel of door sensors ===
956 +=== 3.3.6  Number of channel of door sensors ===
1006 1006  
1007 1007  
1008 1008  Feature: Set the number of door sensor channels.
... ... @@ -1031,7 +1031,7 @@
1031 1031  Example:  0D aa => AT+TTRCHANNEL = second byte
1032 1032  
1033 1033  
1034 -=== 3.3.8  Set Time Sync Mode ===
985 +=== 3.3.7  Set Time Sync Mode ===
1035 1035  
1036 1036  
1037 1037  Feature: Enable/Disable Sync system time via LoRaWAN MAC Command (DeviceTimeReq), LoRaWAN server must support v1.0.3 protocol to reply to this command.
... ... @@ -1069,13 +1069,13 @@
1069 1069  0x28 00  ~/~/ Same As AT+SYNCMOD=0
1070 1070  
1071 1071  
1072 -=== 3.3.9  Clear the open door times and the duration of the last open door ===
1023 +=== 3.3.8  Clear the open door times and the duration of the last open door ===
1073 1073  
1074 1074  
1075 1075  (% style="color:blue" %)**AT Command:**
1076 1076  
1077 -(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %)
1078 -|=(% style="width: 163px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 290px; background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 57px;background-color:#D9E2F3;color:#0070C0" %)**Response**
1028 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:500px" %)
1029 +|=(% style="width: 155px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 288px; background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 57px;background-color:#D9E2F3;color:#0070C0" %)**Response**
1079 1079  |(% style="width:155px" %)AT+CLRC|(% style="width:259px" %)clear the open door times and the duration of the last open door.|(% style="width:44px" %)(((
1080 1080  OK
1081 1081  )))
... ... @@ -1085,7 +1085,7 @@
1085 1085  The sensor will clear the open door times and the duration of the last open door.
1086 1086  
1087 1087  
1088 -=== 3.3.10  Set the count value of the number of open door ===
1039 +=== 3.3.9  Set the count value of the number of open door ===
1089 1089  
1090 1090  
1091 1091  (% style="color:blue" %)**AT Command:**
... ... @@ -1141,8 +1141,6 @@
1141 1141  * (Recommanded way) OTA firmware update via wireless:** [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/Firmware%20OTA%20Update%20for%20Sensors/>>url:http://wiki.dragino.com/xwiki/bin/view/Main/Firmware%20OTA%20Update%20for%20Sensors/]]**
1142 1142  * Update through UART TTL interface: **[[Instruction>>url:http://wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H1.LoRaSTv4baseHardware]]**.
1143 1143  
1144 -
1145 -
1146 1146  = 6. FAQ =
1147 1147  
1148 1148  
... ... @@ -1170,8 +1170,6 @@
1170 1170  
1171 1171  * (% style="color:red" %)**CN470**(%%): LoRaWAN CN470 band
1172 1172  
1173 -
1174 -
1175 1175  = 8. ​Packing Info =
1176 1176  
1177 1177  
... ... @@ -1189,8 +1189,6 @@
1189 1189  
1190 1190  * Weight / pcs : g
1191 1191  
1192 -
1193 -
1194 1194  = 9. Support =
1195 1195  
1196 1196  