From version < 37.1 >
edited by Saxer Lin
on 2023/07/12 11:13
To version < 34.59 >
edited by Xiaoling
on 2023/07/01 15:50
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.Saxer
1 +XWiki.Xiaoling
Content
... ... @@ -71,6 +71,8 @@
71 71  * Wall Mountable
72 72  * Outdoor Use
73 73  
74 +
75 +
74 74  == 1.3 Specification ==
75 75  
76 76  
... ... @@ -104,6 +104,8 @@
104 104  * Sleep Mode: 5uA @ 3.3v
105 105  * LoRa Transmit Mode: 125mA @ 20dBm, 82mA @ 14dBm
106 106  
109 +
110 +
107 107  == 1.4 Applications ==
108 108  
109 109  
... ... @@ -137,6 +137,8 @@
137 137  )))
138 138  |(% style="width:167px" %)Fast press ACT 5 times.|(% style="width:117px" %)Deactivate Device|(% style="width:225px" %)(% style="color:red" %)**Red led**(%%) will solid on for 5 seconds. Means Device is in Deep Sleep Mode.
139 139  
144 +
145 +
140 140  == 1.7 BLE connection ==
141 141  
142 142  
... ... @@ -237,11 +237,8 @@
237 237  === 2.3.1 Device Status, FPORT~=5 ===
238 238  
239 239  
240 -Include device configure status. Once DS03A-LB Joined the network, it will uplink this message to the server. After that, DS03A-LB will uplink Device Status every 12 hours.
246 +Users can use the downlink command(**0x26 01**) to ask DS03A-LB to send device configure detail, include device configure status. DS03A-LB will uplink a payload via FPort=5 to server.
241 241  
242 -Users can also use the downlink command**(0x26 01)** to ask DS03A-LB to resend this uplink. This uplink payload also includes the DeviceTimeReq to get time.
243 -
244 -
245 245  The Payload format is as below.
246 246  
247 247  (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %)
... ... @@ -310,7 +310,7 @@
310 310  === 2.3.2  Sensor Configuration, FPORT~=4 ===
311 311  
312 312  
313 -DS03A-LB will only send this command after getting the downlink command **(0x26 02)** from the server.
316 +DS03A-LB will only send this command after getting the downlink command (0x26 02) from the server.
314 314  
315 315  (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:515px" %)
316 316  |(% colspan="8" style="background-color:#d9e2f3; color:#0070c0; width:515px" %)**Sensor Configuration FPORT=4**
... ... @@ -325,11 +325,6 @@
325 325  Alarm interval(unit: min)
326 326  )))
327 327  
328 -Example parse in TTNv3
329 -
330 -[[image:image-20230630155527-3.png||height="146" width="902"]]
331 -
332 -
333 333  * (((
334 334  (% style="color:blue" %)**TDC: (default: 0x001C20)**
335 335  )))
... ... @@ -355,6 +355,7 @@
355 355  
356 356  Shows the configure value of [[Alarm Base on Timeout Feature>>||anchor="H3.3.3A0AlarmBaseonTimeout"]]
357 357  
356 +[[image:image-20230630155527-3.png||height="146" width="902"]]
358 358  
359 359  
360 360  * (((
... ... @@ -402,9 +402,9 @@
402 402  (% style="color:blue" %)**Count mod:Default=0**
403 403  )))
404 404  
405 -0: Uplink total open door times since factory
404 +MOD=0 ~-~-> Uplink total open door times since factory
406 406  
407 -1: Uplink total open door times since last FPORT=2 uplink.
406 +MOD=1 ~-~-> Uplink total open door times since last FPORT=2 uplink.
408 408  
409 409  
410 410  * (% style="color:blue" %)**TDC flag**
... ... @@ -494,9 +494,9 @@
494 494  (% style="color:blue" %)**Count mod:Default=0**
495 495  )))
496 496  
497 -0: Uplink total open door times since factory
496 +MOD=0 ~-~-> Uplink total open door times since factory
498 498  
499 -1: Uplink total open door times since last FPORT=2 uplink.
498 +MOD=1 ~-~-> Uplink total open door times since last FPORT=2 uplink.
500 500  
501 501  
502 502  * (% style="color:blue" %)**TDC flag**
... ... @@ -752,6 +752,8 @@
752 752  * AT Command via UART Connection : See [[Connection>>http://wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H2.3UARTConnectionforSN50v3basemotherboard]].
753 753  * LoRaWAN Downlink.  Instruction for different platforms: See [[IoT LoRaWAN Server>>http://wiki.dragino.com/xwiki/bin/view/Main/]] section.
754 754  
754 +
755 +
755 755  == 3.2 General Commands ==
756 756  
757 757  
... ... @@ -799,38 +799,11 @@
799 799  * Example 1: Downlink Payload: 0100001E  ~/~/  Set Transmit Interval (TDC) = 30 seconds
800 800  * Example 2: Downlink Payload: 0100003C  ~/~/  Set Transmit Interval (TDC) = 60 seconds
801 801  
802 -=== 3.3.2 Set Power Output Duration ===
803 803  
804 -Control the output duration 5V . Before each sampling, device will
805 805  
806 -~1. first enable the power output to external sensor,
805 +=== 3.3.2  Enable / Disable Alarm ===
807 807  
808 -2. keep it on as per duration, read sensor value and construct uplink payload
809 809  
810 -3. final, close the power output.
811 -
812 -(% style="color:blue" %)**AT Command: AT+5VT**
813 -
814 -(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %)
815 -|=(% style="width: 156px;background-color:#D9E2F3; color:#0070c0" %)**Command Example**|=(% style="width: 204px; background-color: rgb(217, 226, 243); color: rgb(0, 112, 192);" %)**Function**|=(% style="background-color: rgb(217, 226, 243); color: rgb(0, 112, 192); width: 149px;" %)**Response**
816 -|(% style="width:156px" %)AT+5VT=?|(% style="width:204px" %)Show 5V open time.|(% style="width:149px" %)0 (default)
817 -OK
818 -|(% style="width:156px" %)AT+5VT=500|(% style="width:204px" %)Close after a delay of 500 milliseconds.|(% style="width:149px" %)(((
819 -OK
820 -
821 -)))
822 -
823 -(% style="color:blue" %)**Downlink Command: 0x07**(%%)
824 -Format: Command Code (0x07) followed by 2 bytes.
825 -
826 -The first and second bytes are the time to turn on.
827 -
828 -* Example 1: Downlink Payload: 070000  **~-~-->**  AT+5VT=0
829 -* Example 2: Downlink Payload: 0701F4  **~-~-->**  AT+5VT=500
830 -
831 -=== 3.3.3  Enable / Disable Alarm ===
832 -
833 -
834 834  Feature: Enable/Disable Alarm for open/close event. Default value 0.
835 835  
836 836  (% style="color:blue" %)**AT Command: **
... ... @@ -847,7 +847,7 @@
847 847  0xA7 00  ~/~/ Same As AT+DISALARM=0
848 848  
849 849  
850 -=== 3.3.4  Alarm Base on Timeout ===
824 +=== 3.3.3  Alarm Base on Timeout ===
851 851  
852 852  
853 853  DS03A-LB can monitor the timeout for a status change, this feature can be used to monitor some events such as door opening too long etc. Related Parameters are:
... ... @@ -931,7 +931,7 @@
931 931  If user send 0xA9 02 00 00 1E: equal to AT+TTRIG2=0,30  **or**  0xA9 02 00 00 00: Equal to AT+TTRIG2=0,0.
932 932  
933 933  
934 -=== 3.3.5  TTRIG1 & TTRIG2 timeout status alarm ===
908 +=== 3.3.4  TTRIG1 & TTRIG2 timeout status alarm ===
935 935  
936 936  
937 937  It needs to be used with AT+TTRIG1 or AT+TTRIG2. When TTRIG1 or TTRIG2 times out and causes an alarm, and the status does not change subsequently, an alarm packet will be sent at the alarm interval.
... ... @@ -960,7 +960,7 @@
960 960  Example:  0C aa  => AT+TTRALARM= aa
961 961  
962 962  
963 -=== 3.3.6  Count Mod ===
937 +=== 3.3.5  Count Mod ===
964 964  
965 965  
966 966  Feature: Manually set the count mode.
... ... @@ -989,7 +989,7 @@
989 989  Example:  0B aa  => AT+COUNTMOD = second byte
990 990  
991 991  
992 -=== 3.3.7  Number of channel of door sensors ===
966 +=== 3.3.6  Number of channel of door sensors ===
993 993  
994 994  
995 995  Feature: Set the number of door sensor channels.
... ... @@ -1018,7 +1018,7 @@
1018 1018  Example:  0D aa => AT+TTRCHANNEL = second byte
1019 1019  
1020 1020  
1021 -=== 3.3.8  Set Time Sync Mode ===
995 +=== 3.3.7  Set Time Sync Mode ===
1022 1022  
1023 1023  
1024 1024  Feature: Enable/Disable Sync system time via LoRaWAN MAC Command (DeviceTimeReq), LoRaWAN server must support v1.0.3 protocol to reply to this command.
... ... @@ -1056,7 +1056,7 @@
1056 1056  0x28 00  ~/~/ Same As AT+SYNCMOD=0
1057 1057  
1058 1058  
1059 -=== 3.3.9  Clear the open door times and the duration of the last open door ===
1033 +=== 3.3.8  Clear the open door times and the duration of the last open door ===
1060 1060  
1061 1061  
1062 1062  (% style="color:blue" %)**AT Command:**
... ... @@ -1072,7 +1072,7 @@
1072 1072  The sensor will clear the open door times and the duration of the last open door.
1073 1073  
1074 1074  
1075 -=== 3.3.10  Set the count value of the number of open door ===
1049 +=== 3.3.9  Set the count value of the number of open door ===
1076 1076  
1077 1077  
1078 1078  (% style="color:blue" %)**AT Command:**
... ... @@ -1128,6 +1128,8 @@
1128 1128  * (Recommanded way) OTA firmware update via wireless:** [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/Firmware%20OTA%20Update%20for%20Sensors/>>url:http://wiki.dragino.com/xwiki/bin/view/Main/Firmware%20OTA%20Update%20for%20Sensors/]]**
1129 1129  * Update through UART TTL interface: **[[Instruction>>url:http://wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H1.LoRaSTv4baseHardware]]**.
1130 1130  
1105 +
1106 +
1131 1131  = 6. FAQ =
1132 1132  
1133 1133  
... ... @@ -1155,6 +1155,8 @@
1155 1155  
1156 1156  * (% style="color:red" %)**CN470**(%%): LoRaWAN CN470 band
1157 1157  
1134 +
1135 +
1158 1158  = 8. ​Packing Info =
1159 1159  
1160 1160  
... ... @@ -1172,6 +1172,8 @@
1172 1172  
1173 1173  * Weight / pcs : g
1174 1174  
1153 +
1154 +
1175 1175  = 9. Support =
1176 1176  
1177 1177  
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved