Changes for page DS03A-LB/LS -- Outdoor LoRaWAN Door Sensor User Manual
Last modified by Mengting Qiu on 2025/01/10 09:53
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Saxer1 +XWiki.Xiaoling - Content
-
... ... @@ -2,7 +2,7 @@ 2 2 [[image:image-20230516085523-1.jpeg||height="491" width="491"]] 3 3 4 4 5 -**Table of Contents :**5 +**Table of Contents:** 6 6 7 7 {{toc/}} 8 8 ... ... @@ -79,11 +79,6 @@ 79 79 * Supply Voltage: built in 8500mAh Li-SOCI2 battery , 2.5v ~~ 3.6v 80 80 * Operating Temperature: -40 ~~ 85°C 81 81 82 -(% style="color:#037691" %)**Sensor Detect Distance:** 83 - 84 -* Wood Door: 10mm ~~ 30mm 85 -* Iron Door: 30 ~~ 45mm 86 - 87 87 (% style="color:#037691" %)**LoRa Spec:** 88 88 89 89 * Frequency Range, Band 1 (HF): 862 ~~ 1020 Mhz ... ... @@ -172,6 +172,13 @@ 172 172 [[image:Main.User Manual for LoRaWAN End Nodes.PS-LB -- LoRaWAN Pressure Sensor.WebHome@1675143909447-639.png]] 173 173 174 174 170 +== 1.10 Magnet Distance == 171 + 172 + 173 +* Wood Door: 10mm ~~ 30mm 174 +* Iron Door: 30 ~~ 45mm 175 + 176 + 175 175 = 2. Configure DS03A-LB to connect to LoRaWAN network = 176 176 177 177 == 2.1 How it works == ... ... @@ -799,9 +799,39 @@ 799 799 * Example 1: Downlink Payload: 0100001E ~/~/ Set Transmit Interval (TDC) = 30 seconds 800 800 * Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds 801 801 802 -=== 3.3.2 Enable/DisableAlarm===804 +=== 3.3.2 Set Power Output Duration === 803 803 804 804 807 +Control the output duration 5V . Before each sampling, device will 808 + 809 +~1. first enable the power output to external sensor, 810 + 811 +2. keep it on as per duration, read sensor value and construct uplink payload 812 + 813 +3. final, close the power output. 814 + 815 +(% style="color:blue" %)**AT Command: AT+5VT** 816 + 817 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %) 818 +|=(% style="width: 156px;background-color:#D9E2F3; color:#0070c0" %)**Command Example**|=(% style="width: 204px; background-color: rgb(217, 226, 243); color: rgb(0, 112, 192);" %)**Function**|=(% style="background-color: rgb(217, 226, 243); color: rgb(0, 112, 192); width: 149px;" %)**Response** 819 +|(% style="width:156px" %)AT+5VT=?|(% style="width:204px" %)Show 5V open time.|(% style="width:149px" %)0 (default) 820 +OK 821 +|(% style="width:156px" %)AT+5VT=500|(% style="width:204px" %)Close after a delay of 500 milliseconds.|(% style="width:149px" %)((( 822 +OK 823 + 824 +))) 825 + 826 +(% style="color:blue" %)**Downlink Command: 0x07**(%%) 827 +Format: Command Code (0x07) followed by 2 bytes. 828 + 829 +The first and second bytes are the time to turn on. 830 + 831 +* Example 1: Downlink Payload: 070000 **~-~-->** AT+5VT=0 832 +* Example 2: Downlink Payload: 0701F4 **~-~-->** AT+5VT=500 833 + 834 +=== 3.3.3 Enable / Disable Alarm === 835 + 836 + 805 805 Feature: Enable/Disable Alarm for open/close event. Default value 0. 806 806 807 807 (% style="color:blue" %)**AT Command: ** ... ... @@ -818,7 +818,7 @@ 818 818 0xA7 00 ~/~/ Same As AT+DISALARM=0 819 819 820 820 821 -=== 3.3. 3Alarm Base on Timeout ===853 +=== 3.3.4 Alarm Base on Timeout === 822 822 823 823 824 824 DS03A-LB can monitor the timeout for a status change, this feature can be used to monitor some events such as door opening too long etc. Related Parameters are: ... ... @@ -902,7 +902,7 @@ 902 902 If user send 0xA9 02 00 00 1E: equal to AT+TTRIG2=0,30 **or** 0xA9 02 00 00 00: Equal to AT+TTRIG2=0,0. 903 903 904 904 905 -=== 3.3. 4TTRIG1 & TTRIG2 timeout status alarm ===937 +=== 3.3.5 TTRIG1 & TTRIG2 timeout status alarm === 906 906 907 907 908 908 It needs to be used with AT+TTRIG1 or AT+TTRIG2. When TTRIG1 or TTRIG2 times out and causes an alarm, and the status does not change subsequently, an alarm packet will be sent at the alarm interval. ... ... @@ -931,7 +931,7 @@ 931 931 Example: 0C aa => AT+TTRALARM= aa 932 932 933 933 934 -=== 3.3. 5Count Mod ===966 +=== 3.3.6 Count Mod === 935 935 936 936 937 937 Feature: Manually set the count mode. ... ... @@ -960,7 +960,7 @@ 960 960 Example: 0B aa => AT+COUNTMOD = second byte 961 961 962 962 963 -=== 3.3. 6Number of channel of door sensors ===995 +=== 3.3.7 Number of channel of door sensors === 964 964 965 965 966 966 Feature: Set the number of door sensor channels. ... ... @@ -989,7 +989,7 @@ 989 989 Example: 0D aa => AT+TTRCHANNEL = second byte 990 990 991 991 992 -=== 3.3. 7Set Time Sync Mode ===1024 +=== 3.3.8 Set Time Sync Mode === 993 993 994 994 995 995 Feature: Enable/Disable Sync system time via LoRaWAN MAC Command (DeviceTimeReq), LoRaWAN server must support v1.0.3 protocol to reply to this command. ... ... @@ -1027,7 +1027,7 @@ 1027 1027 0x28 00 ~/~/ Same As AT+SYNCMOD=0 1028 1028 1029 1029 1030 -=== 3.3. 8Clear the open door times and the duration of the last open door ===1062 +=== 3.3.9 Clear the open door times and the duration of the last open door === 1031 1031 1032 1032 1033 1033 (% style="color:blue" %)**AT Command:** ... ... @@ -1043,7 +1043,7 @@ 1043 1043 The sensor will clear the open door times and the duration of the last open door. 1044 1044 1045 1045 1046 -=== 3.3. 9Set the count value of the number of open door ===1078 +=== 3.3.10 Set the count value of the number of open door === 1047 1047 1048 1048 1049 1049 (% style="color:blue" %)**AT Command:**