Changes for page DS03A-LB/LS -- Outdoor LoRaWAN Door Sensor User Manual
Last modified by Mengting Qiu on 2025/01/10 09:53
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -243,8 +243,11 @@ 243 243 === 2.3.1 Device Status, FPORT~=5 === 244 244 245 245 246 - Users cansethedownlinkcommand(**0x2601**)toaskDS03A-LBtosenddeviceconfiguredetail,includedeviceconfigurestatus.DS03A-LB will uplinka payloadviaFPort=5toserver.246 +Include device configure status. Once DS03A-LB Joined the network, it will uplink this message to the server. After that, DS03A-LB will uplink Device Status every 12 hours. 247 247 248 +Users can also use the downlink command**(0x26 01)** to ask DS03A-LB to resend this uplink. This uplink payload also includes the DeviceTimeReq to get time. 249 + 250 + 248 248 The Payload format is as below. 249 249 250 250 (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %) ... ... @@ -313,7 +313,7 @@ 313 313 === 2.3.2 Sensor Configuration, FPORT~=4 === 314 314 315 315 316 -DS03A-LB will only send this command after getting the downlink command (0x26 02) from the server. 319 +DS03A-LB will only send this command after getting the downlink command **(0x26 02)** from the server. 317 317 318 318 (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:515px" %) 319 319 |(% colspan="8" style="background-color:#d9e2f3; color:#0070c0; width:515px" %)**Sensor Configuration FPORT=4** ... ... @@ -328,6 +328,11 @@ 328 328 Alarm interval(unit: min) 329 329 ))) 330 330 334 +Example parse in TTNv3 335 + 336 +[[image:image-20230630155527-3.png||height="146" width="902"]] 337 + 338 + 331 331 * ((( 332 332 (% style="color:blue" %)**TDC: (default: 0x001C20)** 333 333 ))) ... ... @@ -353,7 +353,6 @@ 353 353 354 354 Shows the configure value of [[Alarm Base on Timeout Feature>>||anchor="H3.3.3A0AlarmBaseonTimeout"]] 355 355 356 -[[image:image-20230630155527-3.png||height="146" width="902"]] 357 357 358 358 359 359 * ((( ... ... @@ -401,9 +401,9 @@ 401 401 (% style="color:blue" %)**Count mod:Default=0** 402 402 ))) 403 403 404 - MOD=0~-~->Uplink total open door times since factory411 +0: Uplink total open door times since factory 405 405 406 - MOD=1~-~->Uplink total open door times since last FPORT=2 uplink.413 +1: Uplink total open door times since last FPORT=2 uplink. 407 407 408 408 409 409 * (% style="color:blue" %)**TDC flag** ... ... @@ -493,9 +493,9 @@ 493 493 (% style="color:blue" %)**Count mod:Default=0** 494 494 ))) 495 495 496 - MOD=0~-~->Uplink total open door times since factory503 +0: Uplink total open door times since factory 497 497 498 - MOD=1~-~->Uplink total open door times since last FPORT=2 uplink.505 +1: Uplink total open door times since last FPORT=2 uplink. 499 499 500 500 501 501 * (% style="color:blue" %)**TDC flag** ... ... @@ -802,9 +802,41 @@ 802 802 803 803 804 804 805 -=== 3.3.2 Enable/DisableAlarm===812 +=== 3.3.2 Set Power Output Duration === 806 806 807 807 815 +Control the output duration 5V . Before each sampling, device will 816 + 817 +~1. first enable the power output to external sensor, 818 + 819 +2. keep it on as per duration, read sensor value and construct uplink payload 820 + 821 +3. final, close the power output. 822 + 823 +(% style="color:blue" %)**AT Command: AT+5VT** 824 + 825 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %) 826 +|=(% style="width: 156px;background-color:#D9E2F3; color:#0070c0" %)**Command Example**|=(% style="width: 204px; background-color: rgb(217, 226, 243); color: rgb(0, 112, 192);" %)**Function**|=(% style="background-color: rgb(217, 226, 243); color: rgb(0, 112, 192); width: 149px;" %)**Response** 827 +|(% style="width:156px" %)AT+5VT=?|(% style="width:204px" %)Show 5V open time.|(% style="width:149px" %)0 (default) 828 +OK 829 +|(% style="width:156px" %)AT+5VT=500|(% style="width:204px" %)Close after a delay of 500 milliseconds.|(% style="width:149px" %)((( 830 +OK 831 + 832 +))) 833 + 834 +(% style="color:blue" %)**Downlink Command: 0x07**(%%) 835 +Format: Command Code (0x07) followed by 2 bytes. 836 + 837 +The first and second bytes are the time to turn on. 838 + 839 +* Example 1: Downlink Payload: 070000 **~-~-->** AT+5VT=0 840 +* Example 2: Downlink Payload: 0701F4 **~-~-->** AT+5VT=500 841 + 842 + 843 + 844 +=== 3.3.3 Enable / Disable Alarm === 845 + 846 + 808 808 Feature: Enable/Disable Alarm for open/close event. Default value 0. 809 809 810 810 (% style="color:blue" %)**AT Command: ** ... ... @@ -821,7 +821,7 @@ 821 821 0xA7 00 ~/~/ Same As AT+DISALARM=0 822 822 823 823 824 -=== 3.3. 3Alarm Base on Timeout ===863 +=== 3.3.4 Alarm Base on Timeout === 825 825 826 826 827 827 DS03A-LB can monitor the timeout for a status change, this feature can be used to monitor some events such as door opening too long etc. Related Parameters are: ... ... @@ -905,7 +905,7 @@ 905 905 If user send 0xA9 02 00 00 1E: equal to AT+TTRIG2=0,30 **or** 0xA9 02 00 00 00: Equal to AT+TTRIG2=0,0. 906 906 907 907 908 -=== 3.3. 4TTRIG1 & TTRIG2 timeout status alarm ===947 +=== 3.3.5 TTRIG1 & TTRIG2 timeout status alarm === 909 909 910 910 911 911 It needs to be used with AT+TTRIG1 or AT+TTRIG2. When TTRIG1 or TTRIG2 times out and causes an alarm, and the status does not change subsequently, an alarm packet will be sent at the alarm interval. ... ... @@ -934,7 +934,7 @@ 934 934 Example: 0C aa => AT+TTRALARM= aa 935 935 936 936 937 -=== 3.3. 5Count Mod ===976 +=== 3.3.6 Count Mod === 938 938 939 939 940 940 Feature: Manually set the count mode. ... ... @@ -963,7 +963,7 @@ 963 963 Example: 0B aa => AT+COUNTMOD = second byte 964 964 965 965 966 -=== 3.3. 6Number of channel of door sensors ===1005 +=== 3.3.7 Number of channel of door sensors === 967 967 968 968 969 969 Feature: Set the number of door sensor channels. ... ... @@ -992,7 +992,7 @@ 992 992 Example: 0D aa => AT+TTRCHANNEL = second byte 993 993 994 994 995 -=== 3.3. 7Set Time Sync Mode ===1034 +=== 3.3.8 Set Time Sync Mode === 996 996 997 997 998 998 Feature: Enable/Disable Sync system time via LoRaWAN MAC Command (DeviceTimeReq), LoRaWAN server must support v1.0.3 protocol to reply to this command. ... ... @@ -1030,7 +1030,7 @@ 1030 1030 0x28 00 ~/~/ Same As AT+SYNCMOD=0 1031 1031 1032 1032 1033 -=== 3.3. 8Clear the open door times and the duration of the last open door ===1072 +=== 3.3.9 Clear the open door times and the duration of the last open door === 1034 1034 1035 1035 1036 1036 (% style="color:blue" %)**AT Command:** ... ... @@ -1046,7 +1046,7 @@ 1046 1046 The sensor will clear the open door times and the duration of the last open door. 1047 1047 1048 1048 1049 -=== 3.3. 9Set the count value of the number of open door ===1088 +=== 3.3.10 Set the count value of the number of open door === 1050 1050 1051 1051 1052 1052 (% style="color:blue" %)**AT Command:**