From version < 34.55 >
edited by Xiaoling
on 2023/07/01 15:42
To version < 34.50 >
edited by Xiaoling
on 2023/07/01 15:33
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -484,7 +484,7 @@
484 484  
485 485  
486 486  * (((
487 -(% style="color:blue" %)**Count mod:Default=0**
487 +**(% style="color:blue" %)**Count mod:Default=0**
488 488  )))
489 489  
490 490  MOD=0 ~-~-> Uplink total open door times since factory
... ... @@ -564,7 +564,7 @@
564 564  )))
565 565  
566 566  * (((
567 -Each data entry is 11 bytes and has the same structure as [[Real-Time open/close status>>||anchor="H2.3.3A0Real-TimeOpen2FCloseStatus2CUplinkFPORT3D2"]], to save airtime and battery, DS03A-LB will send max bytes according to the current DR and Frequency bands.
567 +Each data entry is 11 bytes and has the same structure as [[Real-Time open/close status>>||anchor="H2.3.2A0Real-TimeOpen2FCloseStatus2CUplinkFPORT3D2"]], to save airtime and battery, DS03A-LB will send max bytes according to the current DR and Frequency bands.
568 568  )))
569 569  
570 570  For example, in the US915 band, the max payload for different DR is:
... ... @@ -816,6 +816,7 @@
816 816  
817 817  DS03A-LB can monitor the timeout for a status change, this feature can be used to monitor some events such as door opening too long etc. Related Parameters are:
818 818  
819 +
819 819  * (((
820 820  (% style="color:blue" %)**Keep Status: Status to be monitor**
821 821  )))
... ... @@ -851,7 +851,7 @@
851 851  **cc dd:** timeout.
852 852  
853 853  
854 -**1) AT+TTRIG1:(PA8 of pin)**
855 +1)**AT+TTRIG1**:(PA8 of pin)
855 855  
856 856  (% style="color:blue" %)**AT Command to configure:**
857 857  
... ... @@ -870,11 +870,13 @@
870 870  
871 871  (% style="color:blue" %)**Downlink Command to configure:**
872 872  
873 -If user send 0xA9 01 01 00 1E: equal to AT+TTRIG1=1,30 **or** 0xA9 01 00 00 00: Equal to AT+TTRIG1=0,0.
874 +If user send 0xA9 01 01 00 1E: equal to AT+TTRIG1=1,30 or
874 874  
876 + 0xA9 01 00 00 00: Equal to AT+TTRIG1=0,0.
875 875  
876 -**2) AT+TTRIG2:(PA4 of pin,need to use AT+TTRCHANNEL=2)**
877 877  
879 +2)**AT+TTRIG2**:(PA4 of pin,need to use AT+TTRCHANNEL=2)
880 +
878 878  (% style="color:blue" %)**AT Command to configure:**
879 879  
880 880  * (((
... ... @@ -892,9 +892,11 @@
892 892  
893 893  (% style="color:blue" %)**Downlink Command to configure:**
894 894  
895 -If user send 0xA9 02 00 00 1E: equal to AT+TTRIG2=0,30  **or**  0xA9 02 00 00 00: Equal to AT+TTRIG2=0,0.
898 +If user send 0xA9 02 00 00 1E: equal to AT+TTRIG2=0,30 or
896 896  
900 + 0xA9 02 00 00 00: Equal to AT+TTRIG2=0,0.
897 897  
902 +
898 898  === 3.3.4  TTRIG1 & TTRIG2 timeout status alarm ===
899 899  
900 900  
... ... @@ -1087,8 +1087,9 @@
1087 1087  
1088 1088  Firmware and changelog can be downloaded from : **[[Firmware download link>>http://wiki.dragino.com/xwiki/bin/view/Main/Firmware%20OTA%20Update%20for%20Sensors/]]**
1089 1089  
1090 -Methods to Update Firmware:
1091 1091  
1096 +**Methods to Update Firmware:**
1097 +
1092 1092  * (Recommanded way) OTA firmware update via wireless:** [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/Firmware%20OTA%20Update%20for%20Sensors/>>url:http://wiki.dragino.com/xwiki/bin/view/Main/Firmware%20OTA%20Update%20for%20Sensors/]]**
1093 1093  * Update through UART TTL interface: **[[Instruction>>url:http://wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H1.LoRaSTv4baseHardware]]**.
1094 1094  
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0