<
From version < 34.53 >
edited by Xiaoling
on 2023/07/01 15:37
To version < 34.50 >
edited by Xiaoling
on 2023/07/01 15:33
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -484,7 +484,7 @@
484 484  
485 485  
486 486  * (((
487 -(% style="color:blue" %)Count mod:Default=0
487 +**(% style="color:blue" %)**Count mod:Default=0**
488 488  )))
489 489  
490 490  MOD=0 ~-~-> Uplink total open door times since factory
... ... @@ -564,7 +564,7 @@
564 564  )))
565 565  
566 566  * (((
567 -Each data entry is 11 bytes and has the same structure as [[Real-Time open/close status>>||anchor="H2.3.3A0Real-TimeOpen2FCloseStatus2CUplinkFPORT3D2"]], to save airtime and battery, DS03A-LB will send max bytes according to the current DR and Frequency bands.
567 +Each data entry is 11 bytes and has the same structure as [[Real-Time open/close status>>||anchor="H2.3.2A0Real-TimeOpen2FCloseStatus2CUplinkFPORT3D2"]], to save airtime and battery, DS03A-LB will send max bytes according to the current DR and Frequency bands.
568 568  )))
569 569  
570 570  For example, in the US915 band, the max payload for different DR is:
... ... @@ -852,7 +852,7 @@
852 852  **cc dd:** timeout.
853 853  
854 854  
855 -**1) AT+TTRIG1:(PA8 of pin)**
855 +1)**AT+TTRIG1**:(PA8 of pin)
856 856  
857 857  (% style="color:blue" %)**AT Command to configure:**
858 858  
... ... @@ -871,11 +871,13 @@
871 871  
872 872  (% style="color:blue" %)**Downlink Command to configure:**
873 873  
874 -If user send 0xA9 01 01 00 1E: equal to AT+TTRIG1=1,30 **or** 0xA9 01 00 00 00: Equal to AT+TTRIG1=0,0.
874 +If user send 0xA9 01 01 00 1E: equal to AT+TTRIG1=1,30 or
875 875  
876 + 0xA9 01 00 00 00: Equal to AT+TTRIG1=0,0.
876 876  
877 -**2) AT+TTRIG2:(PA4 of pin,need to use AT+TTRCHANNEL=2)**
878 878  
879 +2)**AT+TTRIG2**:(PA4 of pin,need to use AT+TTRCHANNEL=2)
880 +
879 879  (% style="color:blue" %)**AT Command to configure:**
880 880  
881 881  * (((
... ... @@ -893,9 +893,11 @@
893 893  
894 894  (% style="color:blue" %)**Downlink Command to configure:**
895 895  
896 -If user send 0xA9 02 00 00 1E: equal to AT+TTRIG2=0,30  **or**  0xA9 02 00 00 00: Equal to AT+TTRIG2=0,0.
898 +If user send 0xA9 02 00 00 1E: equal to AT+TTRIG2=0,30 or
897 897  
900 + 0xA9 02 00 00 00: Equal to AT+TTRIG2=0,0.
898 898  
902 +
899 899  === 3.3.4  TTRIG1 & TTRIG2 timeout status alarm ===
900 900  
901 901  
... ... @@ -1088,8 +1088,9 @@
1088 1088  
1089 1089  Firmware and changelog can be downloaded from : **[[Firmware download link>>http://wiki.dragino.com/xwiki/bin/view/Main/Firmware%20OTA%20Update%20for%20Sensors/]]**
1090 1090  
1091 -Methods to Update Firmware:
1092 1092  
1096 +**Methods to Update Firmware:**
1097 +
1093 1093  * (Recommanded way) OTA firmware update via wireless:** [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/Firmware%20OTA%20Update%20for%20Sensors/>>url:http://wiki.dragino.com/xwiki/bin/view/Main/Firmware%20OTA%20Update%20for%20Sensors/]]**
1094 1094  * Update through UART TTL interface: **[[Instruction>>url:http://wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H1.LoRaSTv4baseHardware]]**.
1095 1095  
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0