Changes for page DS03A-LB/LS -- Outdoor LoRaWAN Door Sensor User Manual
Last modified by Mengting Qiu on 2025/01/10 09:53
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -71,6 +71,8 @@ 71 71 * Wall Mountable 72 72 * Outdoor Use 73 73 74 + 75 + 74 74 == 1.3 Specification == 75 75 76 76 ... ... @@ -104,6 +104,8 @@ 104 104 * Sleep Mode: 5uA @ 3.3v 105 105 * LoRa Transmit Mode: 125mA @ 20dBm, 82mA @ 14dBm 106 106 109 + 110 + 107 107 == 1.4 Applications == 108 108 109 109 ... ... @@ -137,6 +137,8 @@ 137 137 ))) 138 138 |(% style="width:167px" %)Fast press ACT 5 times.|(% style="width:117px" %)Deactivate Device|(% style="width:225px" %)(% style="color:red" %)**Red led**(%%) will solid on for 5 seconds. Means Device is in Deep Sleep Mode. 139 139 144 + 145 + 140 140 == 1.7 BLE connection == 141 141 142 142 ... ... @@ -156,6 +156,7 @@ 156 156 157 157 [[image:image-20230630160843-7.png]] 158 158 165 + 159 159 == 1.9 Mechanical == 160 160 161 161 ... ... @@ -236,11 +236,13 @@ 236 236 === 2.3.1 Device Status, FPORT~=5 === 237 237 238 238 239 - Users cansethedownlinkcommand(**0x2601**)toaskDS03A-LBtosenddeviceconfiguredetail,includedeviceconfigurestatus.DS03A-LB will uplinka payloadviaFPort=5toserver.246 +Include device configure status. Once DS03A-LB Joined the network, it will uplink this message to the server. After that, DS03A-LB will uplink Device Status every 12 hours. 240 240 241 - ThePayloadformat is asbelow.248 +Users can also use the downlink command**(0x26 01)** to ask DS03A-LB to resend this uplink. This uplink payload also includes the DeviceTimeReq to get time. 242 242 243 243 251 +The Payload format is as below. 252 + 244 244 (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %) 245 245 |(% colspan="6" style="background-color:#d9e2f3; color:#0070c0" %)**Device Status (FPORT=5)** 246 246 |(% style="width:103px" %)**Size (bytes)**|(% style="width:72px" %)**1**|**2**|(% style="width:91px" %)**1**|(% style="width:86px" %)**1**|(% style="width:44px" %)**2** ... ... @@ -307,7 +307,7 @@ 307 307 === 2.3.2 Sensor Configuration, FPORT~=4 === 308 308 309 309 310 -DS03A-LB will only send this command after getting the downlink command (0x26 02) from the server. 319 +DS03A-LB will only send this command after getting the downlink command **(0x26 02)** from the server. 311 311 312 312 (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:515px" %) 313 313 |(% colspan="8" style="background-color:#d9e2f3; color:#0070c0; width:515px" %)**Sensor Configuration FPORT=4** ... ... @@ -322,6 +322,11 @@ 322 322 Alarm interval(unit: min) 323 323 ))) 324 324 334 +Example parse in TTNv3 335 + 336 +[[image:image-20230630155527-3.png||height="146" width="902"]] 337 + 338 + 325 325 * ((( 326 326 (% style="color:blue" %)**TDC: (default: 0x001C20)** 327 327 ))) ... ... @@ -347,7 +347,6 @@ 347 347 348 348 Shows the configure value of [[Alarm Base on Timeout Feature>>||anchor="H3.3.3A0AlarmBaseonTimeout"]] 349 349 350 -[[image:image-20230630155527-3.png||height="146" width="902"]] 351 351 352 352 353 353 * ((( ... ... @@ -395,9 +395,9 @@ 395 395 (% style="color:blue" %)**Count mod:Default=0** 396 396 ))) 397 397 398 - MOD=0~-~->Uplink total open door times since factory411 +0: Uplink total open door times since factory 399 399 400 - MOD=1~-~->Uplink total open door times since last FPORT=2 uplink.413 +1: Uplink total open door times since last FPORT=2 uplink. 401 401 402 402 403 403 * (% style="color:blue" %)**TDC flag** ... ... @@ -484,12 +484,12 @@ 484 484 485 485 486 486 * ((( 487 -(% style="color:blue" %)Count mod:Default=0 500 +(% style="color:blue" %)**Count mod:Default=0** 488 488 ))) 489 489 490 - MOD=0~-~->Uplink total open door times since factory503 +0: Uplink total open door times since factory 491 491 492 - MOD=1~-~->Uplink total open door times since last FPORT=2 uplink.505 +1: Uplink total open door times since last FPORT=2 uplink. 493 493 494 494 495 495 * (% style="color:blue" %)**TDC flag** ... ... @@ -745,6 +745,8 @@ 745 745 * AT Command via UART Connection : See [[Connection>>http://wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H2.3UARTConnectionforSN50v3basemotherboard]]. 746 746 * LoRaWAN Downlink. Instruction for different platforms: See [[IoT LoRaWAN Server>>http://wiki.dragino.com/xwiki/bin/view/Main/]] section. 747 747 761 + 762 + 748 748 == 3.2 General Commands == 749 749 750 750 ... ... @@ -792,9 +792,43 @@ 792 792 * Example 1: Downlink Payload: 0100001E ~/~/ Set Transmit Interval (TDC) = 30 seconds 793 793 * Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds 794 794 795 -=== 3.3.2 Enable / Disable Alarm === 796 796 797 797 812 +=== 3.3.2 Set Power Output Duration === 813 + 814 + 815 +Control the output duration 5V . Before each sampling, device will 816 + 817 +~1. first enable the power output to external sensor, 818 + 819 +2. keep it on as per duration, read sensor value and construct uplink payload 820 + 821 +3. final, close the power output. 822 + 823 +(% style="color:blue" %)**AT Command: AT+5VT** 824 + 825 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %) 826 +|=(% style="width: 156px;background-color:#D9E2F3; color:#0070c0" %)**Command Example**|=(% style="width: 204px; background-color: rgb(217, 226, 243); color: rgb(0, 112, 192);" %)**Function**|=(% style="background-color: rgb(217, 226, 243); color: rgb(0, 112, 192); width: 149px;" %)**Response** 827 +|(% style="width:156px" %)AT+5VT=?|(% style="width:204px" %)Show 5V open time.|(% style="width:149px" %)0 (default) 828 +OK 829 +|(% style="width:156px" %)AT+5VT=500|(% style="width:204px" %)Close after a delay of 500 milliseconds.|(% style="width:149px" %)((( 830 +OK 831 + 832 +))) 833 + 834 +(% style="color:blue" %)**Downlink Command: 0x07**(%%) 835 +Format: Command Code (0x07) followed by 2 bytes. 836 + 837 +The first and second bytes are the time to turn on. 838 + 839 +* Example 1: Downlink Payload: 070000 **~-~-->** AT+5VT=0 840 +* Example 2: Downlink Payload: 0701F4 **~-~-->** AT+5VT=500 841 + 842 + 843 + 844 +=== 3.3.3 Enable / Disable Alarm === 845 + 846 + 798 798 Feature: Enable/Disable Alarm for open/close event. Default value 0. 799 799 800 800 (% style="color:blue" %)**AT Command: ** ... ... @@ -811,12 +811,11 @@ 811 811 0xA7 00 ~/~/ Same As AT+DISALARM=0 812 812 813 813 814 -=== 3.3. 3Alarm Base on Timeout ===863 +=== 3.3.4 Alarm Base on Timeout === 815 815 816 816 817 817 DS03A-LB can monitor the timeout for a status change, this feature can be used to monitor some events such as door opening too long etc. Related Parameters are: 818 818 819 - 820 820 * ((( 821 821 (% style="color:blue" %)**Keep Status: Status to be monitor** 822 822 ))) ... ... @@ -852,7 +852,7 @@ 852 852 **cc dd:** timeout. 853 853 854 854 855 -**1) AT+TTRIG1:(PA8 of pin)** 903 +**1) AT+TTRIG1 : (PA8 of pin)** 856 856 857 857 (% style="color:blue" %)**AT Command to configure:** 858 858 ... ... @@ -871,13 +871,11 @@ 871 871 872 872 (% style="color:blue" %)**Downlink Command to configure:** 873 873 874 -If user send 0xA9 01 01 00 1E: equal to AT+TTRIG1=1,30 or 922 +If user send 0xA9 01 01 00 1E: equal to AT+TTRIG1=1,30 **or** 0xA9 01 00 00 00: Equal to AT+TTRIG1=0,0. 875 875 876 - 0xA9 01 00 00 00: Equal to AT+TTRIG1=0,0. 877 877 925 +**2) AT+TTRIG2 : (PA4 of pin,need to use AT+TTRCHANNEL=2)** 878 878 879 -**2) AT+TTRIG2:(PA4 of pin,need to use AT+TTRCHANNEL=2)** 880 - 881 881 (% style="color:blue" %)**AT Command to configure:** 882 882 883 883 * ((( ... ... @@ -895,14 +895,12 @@ 895 895 896 896 (% style="color:blue" %)**Downlink Command to configure:** 897 897 898 -If user send 0xA9 02 00 00 1E: equal to AT+TTRIG2=0,30 944 +If user send 0xA9 02 00 00 1E: equal to AT+TTRIG2=0,30 **or** 0xA9 02 00 00 00: Equal to AT+TTRIG2=0,0. 899 899 900 - 0xA9 02 00 00 00: Equal to AT+TTRIG2=0,0. 901 901 947 +=== 3.3.5 TTRIG1 & TTRIG2 timeout status alarm === 902 902 903 -=== 3.3.4 TTRIG1 & TTRIG2 timeout status alarm === 904 904 905 - 906 906 It needs to be used with AT+TTRIG1 or AT+TTRIG2. When TTRIG1 or TTRIG2 times out and causes an alarm, and the status does not change subsequently, an alarm packet will be sent at the alarm interval. 907 907 908 908 (% style="color:blue" %)**AT Command:** ... ... @@ -929,7 +929,7 @@ 929 929 Example: 0C aa => AT+TTRALARM= aa 930 930 931 931 932 -=== 3.3. 5Count Mod ===976 +=== 3.3.6 Count Mod === 933 933 934 934 935 935 Feature: Manually set the count mode. ... ... @@ -958,7 +958,7 @@ 958 958 Example: 0B aa => AT+COUNTMOD = second byte 959 959 960 960 961 -=== 3.3. 6Number of channel of door sensors ===1005 +=== 3.3.7 Number of channel of door sensors === 962 962 963 963 964 964 Feature: Set the number of door sensor channels. ... ... @@ -987,7 +987,7 @@ 987 987 Example: 0D aa => AT+TTRCHANNEL = second byte 988 988 989 989 990 -=== 3.3. 7Set Time Sync Mode ===1034 +=== 3.3.8 Set Time Sync Mode === 991 991 992 992 993 993 Feature: Enable/Disable Sync system time via LoRaWAN MAC Command (DeviceTimeReq), LoRaWAN server must support v1.0.3 protocol to reply to this command. ... ... @@ -1025,13 +1025,13 @@ 1025 1025 0x28 00 ~/~/ Same As AT+SYNCMOD=0 1026 1026 1027 1027 1028 -=== 3.3. 8Clear the open door times and the duration of the last open door ===1072 +=== 3.3.9 Clear the open door times and the duration of the last open door === 1029 1029 1030 1030 1031 1031 (% style="color:blue" %)**AT Command:** 1032 1032 1033 -(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:50 0px" %)1034 -|=(% style="width: 1 55px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 288px; background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 57px;background-color:#D9E2F3;color:#0070C0" %)**Response**1077 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %) 1078 +|=(% style="width: 163px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 290px; background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 57px;background-color:#D9E2F3;color:#0070C0" %)**Response** 1035 1035 |(% style="width:155px" %)AT+CLRC|(% style="width:259px" %)clear the open door times and the duration of the last open door.|(% style="width:44px" %)((( 1036 1036 OK 1037 1037 ))) ... ... @@ -1041,7 +1041,7 @@ 1041 1041 The sensor will clear the open door times and the duration of the last open door. 1042 1042 1043 1043 1044 -=== 3.3. 9Set the count value of the number of open door ===1088 +=== 3.3.10 Set the count value of the number of open door === 1045 1045 1046 1046 1047 1047 (% style="color:blue" %)**AT Command:** ... ... @@ -1097,6 +1097,8 @@ 1097 1097 * (Recommanded way) OTA firmware update via wireless:** [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/Firmware%20OTA%20Update%20for%20Sensors/>>url:http://wiki.dragino.com/xwiki/bin/view/Main/Firmware%20OTA%20Update%20for%20Sensors/]]** 1098 1098 * Update through UART TTL interface: **[[Instruction>>url:http://wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H1.LoRaSTv4baseHardware]]**. 1099 1099 1144 + 1145 + 1100 1100 = 6. FAQ = 1101 1101 1102 1102 ... ... @@ -1124,6 +1124,8 @@ 1124 1124 1125 1125 * (% style="color:red" %)**CN470**(%%): LoRaWAN CN470 band 1126 1126 1173 + 1174 + 1127 1127 = 8. Packing Info = 1128 1128 1129 1129 ... ... @@ -1141,6 +1141,8 @@ 1141 1141 1142 1142 * Weight / pcs : g 1143 1143 1192 + 1193 + 1144 1144 = 9. Support = 1145 1145 1146 1146