Changes for page DS03A-LB/LS -- Outdoor LoRaWAN Door Sensor User Manual
Last modified by Mengting Qiu on 2025/01/10 09:53
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -484,7 +484,7 @@ 484 484 485 485 486 486 * ((( 487 -(% style="color:blue" %)Count mod:Default=0 487 +(% style="color:blue" %)**Count mod:Default=0** 488 488 ))) 489 489 490 490 MOD=0 ~-~-> Uplink total open door times since factory ... ... @@ -816,7 +816,6 @@ 816 816 817 817 DS03A-LB can monitor the timeout for a status change, this feature can be used to monitor some events such as door opening too long etc. Related Parameters are: 818 818 819 - 820 820 * ((( 821 821 (% style="color:blue" %)**Keep Status: Status to be monitor** 822 822 ))) ... ... @@ -852,7 +852,7 @@ 852 852 **cc dd:** timeout. 853 853 854 854 855 -**1) AT+TTRIG1:(PA8 of pin)** 854 +**1) AT+TTRIG1 : (PA8 of pin)** 856 856 857 857 (% style="color:blue" %)**AT Command to configure:** 858 858 ... ... @@ -871,13 +871,11 @@ 871 871 872 872 (% style="color:blue" %)**Downlink Command to configure:** 873 873 874 -If user send 0xA9 01 01 00 1E: equal to AT+TTRIG1=1,30 or 873 +If user send 0xA9 01 01 00 1E: equal to AT+TTRIG1=1,30 **or** 0xA9 01 00 00 00: Equal to AT+TTRIG1=0,0. 875 875 876 - 0xA9 01 00 00 00: Equal to AT+TTRIG1=0,0. 877 877 876 +**2) AT+TTRIG2 : (PA4 of pin,need to use AT+TTRCHANNEL=2)** 878 878 879 -**2) AT+TTRIG2:(PA4 of pin,need to use AT+TTRCHANNEL=2)** 880 - 881 881 (% style="color:blue" %)**AT Command to configure:** 882 882 883 883 * ((( ... ... @@ -895,11 +895,9 @@ 895 895 896 896 (% style="color:blue" %)**Downlink Command to configure:** 897 897 898 -If user send 0xA9 02 00 00 1E: equal to AT+TTRIG2=0,30 895 +If user send 0xA9 02 00 00 1E: equal to AT+TTRIG2=0,30 **or** 0xA9 02 00 00 00: Equal to AT+TTRIG2=0,0. 899 899 900 - 0xA9 02 00 00 00: Equal to AT+TTRIG2=0,0. 901 901 902 - 903 903 === 3.3.4 TTRIG1 & TTRIG2 timeout status alarm === 904 904 905 905 ... ... @@ -1030,8 +1030,8 @@ 1030 1030 1031 1031 (% style="color:blue" %)**AT Command:** 1032 1032 1033 -(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:50 0px" %)1034 -|=(% style="width: 1 55px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 288px; background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 57px;background-color:#D9E2F3;color:#0070C0" %)**Response**1028 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %) 1029 +|=(% style="width: 163px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 290px; background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 57px;background-color:#D9E2F3;color:#0070C0" %)**Response** 1035 1035 |(% style="width:155px" %)AT+CLRC|(% style="width:259px" %)clear the open door times and the duration of the last open door.|(% style="width:44px" %)((( 1036 1036 OK 1037 1037 )))